HomeMy WebLinkAboutCOLEMAN Block 2 Lot 1
April 22, 1977
First National Bakk of Anchorage
Mortgage Loan Section
Post Office Box 720
Anchorage, Alaska 99510
Attention: Marie Iiams
SubJectI L~t 1 Block 2 Coleman Subdivision
The well serving the subject property is improperly constructed
and does not meet the Municipality minimum require~ standards
~nd must be upgraded before final approval can be granted.
The requirement for wells is that the casing must baa%xtended
a minimum of twelve (12) inches above the ground surface and
be closed with a sanitary seal of a type approved by this
department.
The existing pit must be filled with mn-porous soil and the
ground sloped to drain away from the well casing.
This department will, however, grant temporary_approval if
funds are escrowed to complete the upgrade ~June 1, 1977~
If there are any further questions, please contact this office
at 279-2511, extension 224 or 225.
Sincerely,
John Kennedy
Principal Environmental Code Officer
cc: Richard M/Leontine E. K~abe
8001 East 5th Avenue 99504
UNICIPALITY
9~P~~ HEALTH OF ANCHORAGE
AN]3 ENVIRONMEN1 .,PROTECTION
825 L Street, Anchorage, Alaska'" .99501
279-2511, ext. 224 or 225
Date Received: April 15, 1977
#1: Time ~:~ ~r~ #2- Time #3' Time
Date £/-;q-77 ~% Date Date
Insp /~ L ~/~ ~ Insp Insp
REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES
1. Lending Institution Request: First National Bank of Anchorage
Mailing Address: Post Office Box 720
99510 Phone: 276-6300/483
2. Property Owner: Richard M/Leontine E. Knabe Phone:
Mai~ing Address: 8001 East 5th Avenue 99504
333-4838
3. Legal Description: Lot 1 Block 2 Coleman Subdivision
See attached map
4: Single Family Residence: ~ Number of Bedrooms:
Multiple Family Residence: ( ) Number of Bedrooms:
3
Well System:
Permit #
Construction
Public/Community System: ( ) Individual Well: (~
Depth of Well Well Log on File ( )
Bacterial Analysis . .
Sewage Disposal System:
Permit #
Septic Tank Size
Absorption Area
On-site-System ( )
Installed
Public Utility
Installer
Manufacturer
Soils Rate
Material
7. Distances: Well to Septic Tank
to Sewer Line
Nearest Lot line
to Nearest Lot Line
to Absorption Area
Absorption Area
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
2510 East Tudor Road, Anchorage, Alaska 99504 276-2221
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
1. Type of Inspection: CMRO VA
2. Property Owner: Richard M. & Lecntine E. Knab~
Mailing Address: 8001 East 5~h A~en~
3. Name of Buyer:
Mailing Address:
4. Name of Lending Institution:
Mailing Address:,
5. Name of Realtor or Agent:
FHA
Day Phone:
Job_q E. & Sondra K. Harris
CONV X
333-4838
24-332 Daisy Crt Elmendor~)ay Phone:
First National Bank ofAnchoraqe
P. O. Box 720 Phone:
Muldoon Realtvl Toby Tobler aqen~,
752-4953
276-6300 e~ 483
Mailing Address:
Legal Description:
Location:
322 Muldoon Road
Lot 1 t Blk 2 t · Coleman S/D
8001 East 5th Avenue
Phone:
337-1577
7. Type of Facility to be Inspected:
8. Water Supply
Type of Supply:
existinq Sinqle Family
No. Bdrms. 3
Public Utility
Individual
If Individual, number of dwellings presently served
If Individual, depth of well
Sewage Disposal System
Type of System:
Public Utility
Individual (on-site)
If Individual, date of installation
72-OO3(3/76)
~rie Iiams 4/13/77
Page Two
~' Department of Health and Environmental Protection
r Request for Approval of Individual Sewer and Water Facilities
Legal Description:
Lot 1 Block 2 Coleman Subdivision
Comments:
Affadavit Attached:
Approved:
Disapproved:
Department Worksheet:
· Date:
Date:
Letter Attached: ( )
06-1220~a) ,.R~v. 1973
DATE
AL/~)DEPARTMENT OF HEALTH AND SOCIAL S~ES
DIVISION OF PUBLIC HEALTH
INDIVIDUAL AND SEMI-PUBLIC
BACTERIOLOGICAL WATER ANALYSIS
Lab No.
OFFICE
INDIVIDUAL ~' SEMI-PUBLIC [] CHLORINE RESIDUAL PPM '
REPORT RESULTS TO
ADDRESS "'
OF SOURCE
.... COMPLETE THIS SECTION
ONLY IF, W~TER~IS AN INDIVIDUAL SUPPLY
SAMPLE COLLECTED BY
,..- 77 -' -
~(V- ~/, ~'-;,-'--' >
DATE COLLECTED " ~ ' I TIME 'COLLECTED
Sample Collected From I~Kitchen Tap [] Bathroom Tap [] Basement Tap
[] Other (List)
Well -- J~] Dug [] Driven B Drilled [] Bored
SOURCE: [] Spring [~]~ Cistern Other__
Dug Well or Cistern Constructiom'
Walls--~] Wood [] Concrete
Metal
Top -- [] Wood [] Concrete []
Metal
LOCATIQ N:
[] In Basement [] Basement Offset
l-lin Yard [] Other -
Building Sewer
DISTANCE TO: or Other Drainage Pipe
Tile' . Seepage Cess-
Field Feet. Pit Feet. Pool
Other Pos~ible
Sources of Contamination
MATERIAL: Building Sewer- [] Cast Iron [] Wood [] Tile
[] Plastic Joint Material - Type
GENERAL: Does Water Become Muddy or Discolored?
When?
B Tile Brick or
Open Top [] Con~t'~ete
[] Under House
Septic
Feet. Tank ' Feet,
Feet· Privy ~ ~'~Feet,
[] Fibre [] Asbestos ' .-
Cement
[] Yes
~et.
.Feet.
~ In Utillty
[] Room ~
Diameter of Well , Depth
Well Casing
Material Diameter __ Depth
Length of Water Depth
. Drop Pipe From Bottom
Offset in
PUMP LOCATION: [] In Well [] Basement .~'~ I~ Basement
On ~to~ i Other
D of []
PURPOSE OF EXAMINATION: Illness Suspected?~ [] Yes
New Source of Supply? [] Yes [~ No: Repairs to System?
[] No
[] Yes D No Signature
~, /' Analysis shows~,this Water SAMPLE to be:
X .
,~r~'l Satisfactory
[] Unsatisfactory
[] Questiopable
[] Sample to~I' Ion, in-transit; sample should not be over
hou~s old.at examlndtlon to indlcate reliable results. Please
send new sample~
[] Bottle broken in transit, please send new sample.
SANITARIAN'S REMARKS
READ INSTRUCTIONS .....
~ON
REVERSE SIDE
BEFORE
COLLECTING SAM PJI~E
06-1220Rev, 1973~b>BACTERIOLOGICAL WATER ANALYSIS..,RECORD .
Da,e ..c.i~ed
Lactose Broth ,,, /;' 10cc 10cc 10cc 10cc 10cc ' 1.0cc 1.0cc
24 Hours '
48 Hours
Brilliant Green
24 Hours
48 Hours
EMB AGAR
Lactose Broth, 24 hrs. 48 hrs. Gram's stain
Coliform Density (Most probable No. per 100cc)
MF Results
/Reported by ' ~
This analysis indicates Coliform Organisms to be:
DIRECTIONS FOR COLLECTING SAMPLES OF WATER FOR BACTERIOLOGICAL EXAMINATION-
Read Carefully and Follow Instructions Exactly
Bear in mind that water analysis deals with materials present in very minute quantities. The least care-
lessness-in collecting and handling may give rise to results which are misleading.
Samples are accepted at the regional laboratories in .the early part of the week (Monday-Wednesday)
unless there is an emergency or prior arrangements have been made. 'Arrangements should be made to
have the water samples reach the laboratory as quickly as possible and within 48 hours, after collection.
After 48 hours, the significance of the bacteriological analysis is impaired.
In collecting samples from TAPS or PUMPS proceed-as follows:
~(a)· Thoroughly flush tap or pump by allowing,w.ater to run freely for five minutes.
(b) Shut off water and flame the Outlet with tolich or burning paper. The flame should not be
merely passed over the outlet but should be applied until fixture-shows indication of being
hot. Flame should be directed against inside edge.
(c) Open fixture so that a small stream flows.
(d) Remove bottle from mailing tube. Hold b~ttle' by the lower half in one hand and with the other
remove the screw cap with the fingers, leaving foil protecting cover in place. Fill the bottle to
the shoulder. Replace cap with foil cover, ,screwing firmly into place but do not apply pres-
sure which will split cap. :
(e) Pack bottle carefully in mailing tube enclosirig this completed information sheet.
DO NOT COLLECT SAMPLES FRoM FIRE HYDRANTS, YARD
HYDRANTS, DRINKING FOUNTAINS OR SIMILAR OUTLETS
WHICH ARE DIFFICULT TO DISINFECT PROPERLY.
STERILE WATER,~SAMPLE BOTTLES ARE AVAILABLE UPON REQUEST ~FROM:
Dept. of' Health & Social Services Dept. of Health & Social Services Dept. of HegJfh & Social Services
Southeastern Regional Sanitarian Southcentral Reg,lonal Sanitarian Northern Regional Sanitarian
Pouch J 338 Denall Street, MacKay Bldg. 604 Barnette Street
Juneau, Alaska 99801 Anchorage, Alaska 99501 Fairbanks, Alaska 99701
Or District Offices in Fairbanks, Juneau, Ketchikan; .Kodiak, Nome, Palmer, Soldotna and Valdez. Consult local telephone- directory for
sanitation offices located in these communities. Anchorage area Ncontact Greater Anchorage Area Borough Department of Envlron.
mental Quality.