Loading...
HomeMy WebLinkAboutCROMWELL HEIGHTS BLK 1 LT 2II itt;s' L-- - OS e 4. 5. e GREATER ANCHORAGE AREA BOROUGH~ Department of Environmental quelity 3500 Tudor Road, Anchorage, Alaska 99507 279-8686 Date Received Time of Inspection ] 0 ',~ C~ Date of Inspection ~7/} REQUEST FOR APPROVAL' OF INDIVIDUAL SEWER & WATER FACILITIES FOR "' ' Location: Type of Facility to be Inspected.' Number of Bedrooms: Well Data.' ~ Installed Septic Tank: Seepage Pit: 1. Disposal Field: Ae / B. Depth ~ ~ D. Bacterial Analysis' C. Construction Sewage Disposal System: 1. Size 7~f2"/~70~2. ~nufaeturer Size ~/ 2. ~atertal Total Length of Lines ---'--'------- Distances: _,<'-/ 7 x ' A. Well To: Septic Tank _ '/., Absorption. Area , Sewer Lines ~ , Nearest, Lot Line -~ , Other Contamination . Foundation to Septic Tank /~ /:', Absorption Area ~/'_ Absorption Area to Nearest Lot Line ,_) Request-for Approval l~age' Two g. Comments: dividua] Sewer & Water Facile' Approvedv ' ' ~~ Disapproved Date . ~, Approval Valid for One Year From Date Signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGEAM OF SYSTEE l' certify that the information contained in this request for approval to be a true and accurate representation of the subject' sewe~and wat~ faci!i, ties located at: / MUNICIPALITY OF ANCHORAGE ON-SITE WA TER/WASTEWA TER DISPOSAL SYSTEM FIELD AUDIT Date ~'~-~ Document Type -/ Legal Description Site Address / Engineer/Firm ~~_/~_~.~// Excavator Inspection Findings_ Initials /~-' / _ Follow-up Notes Time /463-5-92 T_ SPURKLAI~ID P- E- W. DIMOND BLVD. ANCHORAGE, ALASKA 99502-3904 (907) 279-5916 Municipality of Anchorage Division of Environmental Health Department of Health and Social Services 820 I Street Anchorage, Alaska 99501 Mr. Robbie Robinson SubJect: ON SITE SEWER SYSTEM PERMIT APPLICATION Lot 2 Block 1 Cromwell Heights September 6, 1995 RECEIVED SEP 919g Municip~hty ot Anciqorag. e Dept. Health & Human Serwces Gentlemen; An application for a septic system up grade was submitted on August 13, 1995. The transmittal indicated groundwater at 5 feet. On August 22 and again on August 51 groundwater was found at 2 feet. Based on these observations the proposed septic system permit was denied. Several testholes were dug on this property on ~uly 16, 1995. All showed the identical general condition with groundwater at very shallow depth. Based on these observations a holding tank is presently the only approved system that can be installed. The "Orenco Sand Filter" is presently being installed at several places for evaluation and testing. This system has proved itself on the West Coast and in the Mid West. There seems to be a general acceptance of this system here in Anchorage, with a high confidence of its performance. I request permission to install this system on this lot. If this permission is granted, with provisions of testing and monitoring, I will submit detailed drawings of the required installation. NOTE: Application must be filled out completely. Property Owner Name Mailing Address Legal Description MUNICIPALITY OF ANCHORAGE Department of Health & Human services On-Site Sewer/Well Permit Application SINGLE FAMILY DWELLING L.o T '2. Lot Lot Size Parcel Identification Number Number of Bedrooms: ~ L,~'~ \(~ [.O ~ ¢0~[-. ~ ~ 0.,,¢~ Municipality (permit fee included) ---. Does your house contain any of the following: Hot Tub, Swimming Pool, Therapy Pool, Jacuzzi, or Water Softener Unit? If yes, which one? This application is for: Sewer Only Sewer and Well __ Sewer Upgrade /~/ Well Only I certify that the above information is correct. I further certify that this application is being made for a Single Fal~Ml~w~ing and in accordance with applicable Municipal codes. ~k"'".,..--3 ,-~ Property/wner/Well Driller Fees: 7.-~)0 ' f,)'O Receipt # '~"~ 4J"~ T--'-"'-- ~ L/'~'~-Z',/~¢/Permit~"~ # 72-012 fRev. 10/86) Day Phone Code ?q Si ; I Block Subdivisio(~ .~ ~... ~,~...~ ' I '~..J~ '~ '~ L,~Range~'~ ~ Section 'r~wnshi;~ A~'~Sq. Ff Inspections will be conducted by: ~ :~ Z~ ,~- I'"/ Approved Engineering Firm (-~ ~'3 m ~. P- E. LOT 2 T- SPURKLAND 205 W 15th. Avenue, Suite 206 ANCHORAGE, ALASKA 99501 (907) 279-5916 SEPTIC SYSTEM DESIGN BLOCK I CROMWELL ROBERT HUFFMAN HEIGHTS Ground Water at 5 ft. Use Pressurized Mound with 4 ft of filtersand Loading Rate: .7 gal/sq.ft. Required Area per Bedroom: 150/ .7 = 214 sq.ft.. Number of Bedrooms 2 Bed Area 2 x 214 = 428 sq.ft. SYSTEM CONFIGURATION MOUND TOTAL LENGTH TOTAL WIDTH TOTAL DEPTH ROCK DEPTH COVER 25 FT. 20 FT. 2 FT. .5 FT. 5 FT. ABANDON EXISTING SYSTEM PUMP AND CRUSH EXISTING TANK PUMP, CRUSH, AND BACKFILL EXISTING PIT The installation of this septic system will not prevent wells from be installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. Septic Sy~-i:em i)esign Lot 2 Block 1 Cr'o~'~wel]. Heights p g. t PERFORMED FOR: ~ O LEGAL DESCRIPTION: Township, Range, Section: SLOPE Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 %" Street, Anchorage, Alaska 99502-0650 SOILS LOG PERCO~TION TEST DATE PERFORMED: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT O !,i DEPTH? p E Depth to Water After 'i.,. Monitoring? ~) Dale: SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN __ FT AND __ FT COMMENTS PERFORMED BY: "~" ~'~ I '~""~' '~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~..-~ 72-008 (Rev. 4/85) 43O SQ F T MOUND ---~ '1 I I I I I 25 8 ~ I I I I (.ATE SCALE; I' = 50 FT. I I L 1250 GAL STEP TANK ABANDONE EXIST, LI I 150 TQB~EN SPURKLAN~ P,E, 203 ~ 15TH, AVENUE ANCH, AK, 99501 LOTS ~£I.~, AN~ 1£ ~LDCKI CROIfl~'ELL HE]6HTS RO, BERT HOFFNAN SEPTIC SYSTEM DESIGN ])ATE, AUG, ~,~, i993 SHEET, 2/3 GRID, 2659 2 o °I 1250 GAL STEP TANK Foundo~ion Cleon ouf 430 SQ, FT MOUND 1/8" HOLES AT I2'" 4 X 18' 1,5 DIST,~I.~UTION PIPES 4' C-TO -C IBEN SPURKLAND P,E. 203 W, 15TH ANCHORAGE, AK, 99501 LOT 2 ~LDCK 1 C/~ITM~ELL SEC, 23, TI2N t~3~/ ~O~BENI' HUFFMAN 1~400 HILLSIDE DgIVE SEPTIC SYSTEN DESIGN :DATE, AUG, ]3, 1993 SHEET, 3/4 ORI:D, 2639