HomeMy WebLinkAboutCROMWELL HEIGHTS BLK 1 LT 4PARCEL
015-
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP251219
Work Type: WellSeptic Upgrade
Tax Code Number: 01533203000
Site Legal Address: CROMWELL HEIGHTS BLK 1 LT 4 G:2639
Site Mailing Address: 11300 HILLSIDE DR, Anchorage
Owner: CALHOUN KAYTLIN M & IAN F
Design Engineer:
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
7/22/2025
7/22/2026
32000
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
5
Special Provisions: A test hole is required prior to construction of the absorption field to confirm minimum
separation to impermeable soil and seasonal high groundwater. If results require a design change, construction
shall stop pending approval of a change order. Please submit results with the inspection report (or change order,
if required).
Received By: F Date:
Issued By: Date:
MUNICIPALITY OF
Development Services Department
On -Site Water & Wastewater Section
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 015-332-03
Property owner(s) KAYTLIN & IAN CALHOUN Day phone
Mailing address 11300 HILLSIDE DRIVE, ANCH, AK 99507
Site address 11300 HILLSIDE DRIVE, ANCH, AK 99507
Legal description CROMWELL HTS B 1, L4
Number of Bedrooms 5
Engineering Firm FIRST WATER CONSULTING
'7�
Building Permit Number 1 " 7'. �— — 2-
APPLICATION IS FOR:
APPLICATION IS AN:
(Z all that apply)
Disposal Field
F-I Initial 0
Septic Tank
M Upgrade 0
Holding Tank
0 Renewal D
Privy
0
Well
El
Water Storage
0
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Permit/Rush Fees: Os
Date of Payment: 71112,s
Permit No. 05P X 21q
May 2025
Waiver Fees:
Date of Payment:
Waiver No.
Phone: 907-343-7904
Distance:
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / firstwaterAK@gmail.com
!
!!
July 8, 2025
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: SEPTIC SYSTEM UPGRADE PERMIT
LEGAL: CROMWELL HEIGHTS BLOCK 1, LOT 4
The property owner has requested we obtain a permit to upgrade the failed, defunct septic system
of the above referenced lot. We propose to install one shallow trench and 2 1000-gallon deep
burial HDPE tanks with baffles removed and an effluent pump in the second tank to serve the
proposed 5-bedroom residence. The design is based on the recent test hole conducted in May
2025 by Mike N Anderson, PE.
Groundwater was observed at test hole excavation at 10’ at also at 9’ at monitoring. The area
has shallow groundwater and levels must be verified at construction. Any biomat of the existing
field must be removed and insitu soil or MOA sand installed within 8’ of the proposed field.
The slopes are moderate at 0-5% at the proposed upgrade location. The lot and area are served
by private water as shown. The design will not impact any of the neighboring properties. Please
contact us if you have any questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251219, Curtis Townsend, 07/22/25
FIRST WATER CONSULTING
CROMWELL HEIGHTS BLOCK 1, LOT 4
DESIGN CALCS:
NO WELLS WITHIN 100' OF PROPOSED
SEPTIC TANKS & FIELDS. AREA HAS
SHALLOW GROUNDWATER - VERIFY
PRIOR TO CONSTRUCTION. DESIGN
BASED OFF MIKE N ANDERSON (MNA), PE
TEST HOLE & MNA ALSO PLANS TO INSTALL.
NO SLOPES >25% WITHIN 50'OF PROPOSED FIELD.
STAKE PROPERTY LINES, WELL RADII, ESMTS,
OR OTHER SEPARATIONS... PRIOR TO CONST.
5BR RESERVE: CATIII W/ 3GPD SOILS
750 GAL / 3 GPD/SF = 250 SF / 5 = 50'L
50'L X 0.5 RF (4'ED) = 25'LX5'X4'ED - 5'OG
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251219, Curtis Townsend, 07/22/25
FIRST WATER CONSULTING
DESIGN DETAILS:
CROMWELL HEIGHTS BLOCK 1, LOT 4
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251219, Curtis Townsend, 07/22/25
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251219, Curtis Townsend, 07/22/25
GAAB-HD-I
GI~ iR ANCHORAGE AREA BOROt. '
DE'P
TMENT OF ENVIRONMENTAL QUALITY.-~
3500 TUDOR ROAD ANCHORAGE, ALASKA ggs07 27g-8686
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
MAILING
ADDRESS .~'~'~'~ '~"~.'~""~'~"'~. /~:~'/('""~"//~" PHONE
LEGAL DESCRIPTION ..~..~'~.~-~/
SEPTIC TANK:
DISTANCE FROM WELL
LIQUID CAPACITY ./' ~ GALLONS.
NUMBER OF
MATERIAL ~¢-~":~'~:"~--- COMPARTMENTS
INSIDE LENGTH ~ INSIDE WIDTH ~ DEPTH -------
SEEPAGE SYSTEM: SEEPAGE PIT:
NUMBER OF PITS
LINING MATERIAL .~z:~)
NEAREST LOT LINE
OUTSIDE DIAMETER ~ OR WIDTH /~='~----' , LENGTH ~'"~-~-~ , DEPTH
DISTANCE FROM WELL z''''~-~-~ BUILDING FOUNDATION.
TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA)
SQ. FT.
TILE DRAIN FIELD:
TOTAL LENGTH
DISTANCE FROM WELL __~N '~, NEAREST LOT LINE OF UNES ,
NUMBER OF LINES ///~DISTANCE BETWEEN LINES ~ CHWIDTH IN. TOTAL EFFECTIVE
ABSORPTION SQ. FT. LENGTH OF EACH LIN~ -- --
DEPTH: TOP OF TILE TO FINISH GRADE
DEPTH OF FILTER MATERIAL BENEATH TILE
IN. ABOVE TILE__
WELL:
TYPE ,~'~g-/~ DEPTH
LOT LINE /~ '''~' NEAREST
SEWER LINE '~-) '"~'- SEPTIC
, TANK
DISTANCE FROM .-= x, / WATER
, BUILDING FOUNDATION._,~__~~SAMPLE ~¢'/'~"~'~-~, NEAREST
,,~'~--~ / SEEPAGE / OTHER
SYSTEM ~'/~;~ , CESSPOOL-''(-/~/J/'~-~, SOURCE~
DISTANCES:
DIAGRAM OF SYSTEM
t
DATE
' I
~ GAAB
Pcrfc.,r~:ed PJr Herbert Ballancer- :).:t~.e ~erformed 7/24/71
This F'crm Reports ~ ........ - .......... _ . _ _ ._
Brown silty sand
Gray sandy gravel (GW)
with poorly graded sand
seams
Was Ground }~a~.-:' Knco:;ntar'ed.?~O~ ............
.... :~ ............. -+ .......... -~ ........ __t_~----z---t-------
'-- ' ~;2'i'~e ired er bedroom.
~9 feet qf_.~~9~J,-~,~ .... ~*,- -~~~
Performed }~*~ ~...R_~.E: Car..~.isle
Da*:,~ Cer~.ified 3v: National Testing Services, Inc.
Date ·
August g~, 1~71
Herbert ~11ancer
SI~ ~ox 387 C
lb~c~or4ge, A~aska
Subject: Soll Tes~ Perfor~e~ for On-site Sewage disposal System.
Uear ~r. ~a11~r~cer:
We have r~cetved a soil test from ~atio,al Testing
performed from a ~(erbert t)allance o~ loc 1, bloc~
Subdivision. At the tl~m I did a. fl~al on your sewer s~s~e~ you
advised your legal description) wes lot 4,
Subdivision. Will you please advise tnts Uepart~nt t~ the soil
test ~n~t~ coulU possibly ~ yours) We ~ave no recbrd of
pe~o~d on lot 4, block l, C~ell Heights.
Sincerely,
Carrol Sue i~K~c~snle
~nvtronme~tal Col~trol Officer
st