HomeMy WebLinkAboutCROMWELL HEIGHTS BLK 1 LT 9Cr'omwel I Height lock I Lo1' 9 015-332 -10  Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: OSP111191 PID Number: 015-532-10 Name: JEFF LEONARD WastewaterSystem: [] New · Upgrade Address: 11000 MOUNTAIN LAKE DR. *ANCHORAGE, AK 99516 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 440-8040 4 [] Deep Trench [] Shallow Trench · Bed [] Mound [] Other LEGAL DESCRIPTION ~ol, Rating: Total Depth from original grade: 0.8 GPD/Sq. rt. SEE DWG. Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Grovel depth beneath pipe: 1 9 CROMWELL HEIGHTS SEE DWG. rt. 0.55+ rt, Township: _ Range: _ Section: Fill added above or;ginal grade: Gravel length: SEE DWG. / : Gravel width: Number of lines: Distance between lines: WELL: [] New [] Upgrade 15 rt. 5 5 Pt. Classification (Private, A,B,C): Total Oep[~:l;~~ Cased TO:(BEDROCK Total absorption area: Pipe material: Date Drilled: Static Water Level: Installer: Date installed: Pt. WILCO CONTRACTORS 8/18-19/11  Pump Set At: Casing Height Above Ground: rt.rt. TANK GPM SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P.~ [] Other* i~ To Septic Absorption Lift Holding Public/Private ;From ~ Tank Field Station Tank Sewer Lines ~- -~-~~ Well (.~ 100'+ ~ - 25'+ Mate~ Number of compartments: Su,aoeWoter ~_ 100'+ ~ - - LIFT STATION Lot Line __ ~ 10'+ (j~ _ _ Size in gallons: M~nufa~ ~'~ X "Pump on" level at:__--~l "J~ot: IHigh water alarm at: Curtain Drain ' NONE KNOWN ~ Pump Mak cUons erfo I I Remarks: OLD BED WAS REBUILT, ALL CONTAMINATED BENCH MARK Location and Description: MATERIAL WAS EXCAVATED OUT AND REPLACED WITH SAND. BOTTOM OF SIDING, SOUTH SIDE OF HOUSE. As .... d Elevation: 100.00 rt. ENGINEER'S SEAL Inspections performed by: CEC, Ltd. Dates: 1st 8/18/1 1 Development Services Department Approval ~.~ Conditional approval: Da re: !;.' J~/ffCe~ "*'"'"""'*-": AS BUILT DRAWING OSPl 11191 - O15-$$2-10 MT1 34.36 18.74 ~ ~ MT2 I 41.42 30.84 ~ MT3 77.79 52.16 MT4 81.27 57.75 \ "; '.";'""::":.'::" !' ?i"; i:.!.'.. :":v;':'.' ~","".'.;,.'(~ '.) '; '". i .. ....... .'~ '..,. i; .'. %,,' : . ':~ EXISTING 4 .' ; ~ GALLON STEP TANK. I JEFF LEONARB I 440-~040 I 2 OF 5 i~,_ '-J~¢k¢~ ,~,, ~C,,TO, ,,,~. ,~. k' ~ '/¢ ASBUILT DRAWING 8/22/11 A B MT1 34.36 18.74 MT2 41.42 30.84 MT3 77.79 52.16 MT4 81.27 57.75 (Rev. 01/05) AS BUILT DRAWING OSP111191 - 015-332-10 *LIMITED TO REMOVAL OF CONTAMINATED SOILS. BlED WAS TOPSOILED AND SEEDED /-- FINAL GRADE = 101.82+ ~ INSU~TION ~ ~ FILTER FABRIC / MT ~ / / MT *ORIGINAL GRADE ~ / / / '~"i' ~ CON~i~IA;V~5~F~oIL. .... .... .... : ~:,. :;-.. ~. ..... :, ~-..~ .~.~ .-~...,. x, ,~.~ .~.-, ................ . .................. ~ ~ "' i"~'.'"~"".':''' ":' "':~':'"" '" ':. ~ ~' ,':?.' ':" ' :' .... .}~ ' ; '~".'~ = 99.10 (AVG.) ........ ' ........ ' ................. ' ............. ' ..... ' .... ....... ...: ,, ........ ,, ~:...,,...,:...; ...:.:.; ~.,:.. ~.~. ,..,..-.;.:,.. :.,,,,.: ,:: ,.:.....,,.: ::.: ..~ ~., ,->p :-% :';:% ;:,....~.,...?..,,.~,~ ,BOSOM OF /= 15'WIDE // EXCAVATION / = 97.46-97.86 / (AV0.) ~ THE DISTRIBUTION LINE IS 1.25 INCH PVC WITH ~ INCH HOLES SPACED 60 INCHES ON CENTER. (10 HOLES PER ~TERAL/50 HOLES TOTAL. G.A'RNESS JEFF LEONARD [ 440-80~0 I 3 OF 3 ['~ LECAL DESCRIPTION: DRAWN BY: ~VO~ c~o~w[Lb HmHTS; 8bOC~ ~, LOT 9 PNe ~, ~PE OF WORK: DATE: % .~ OtesslO~'] P.omE a.AW~N~ S/22/~ ~ Permit Number: Tax Code Number: Work Type: Permit Effective Dates: Design Engineer: Subdivision: Site Legal Address: Owner/Address: Site Mailing Address: On-Site Wastewater Disposal System Permit OSPl11191 01533210000 Septic August12,2011 MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 EImore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade to August 11,2012 GARNESS ENGINEERING GROUP LTD CROMWELL HEIGHTS CROMWELL HEIGHTS BLK 1 LT 9 G:2639 LEONARD ALASKA COMMUNITY PROPERTY TRUST LEONARD J & S / TTES 11000 MOUNTAIN LAKE DR ANCHORAGE AK 99 11000 MOUNTAIN LAKE DR, Anchorage Lot Size in Sq Ft: 28800 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field N Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: 1. The septic tank is not required to be inspected. MUNICIPALITY OF ANCHORAGE Community Development Department Development Services On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907- 343-7997 Mayor Dan Sullivan On-Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I.D. 015-332-10 Property owner(s) JEFF LEONARD Day phone C/O AGENT Mailing address 11000 MOUNTAIN LAKE DRIVE *ANCHORAGE, AK 99516 Site address NHN BUFFALO STREET *ANCHORAGE, AK 99516 Legal description (Sub'd, Block & Lot) CROMWELL HEIGHTS; BLOCK 1, LOT 9 Legal description (Township, Section & Range) Lot Size Sq. Ft. Number of Bedrooms 4 THIS APPLICATION IS FOR: ( [] all that apply) Absorption Field [] Septic Tank Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: N/A I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. C~ ~ f~ Waiver Fees: Date of Payment: Receipt Number: Waiver No. (Rev, 01/11) GARNESS ENGINEERING GROUE Ltd. CONSULTANTS & GENERAL CONTRACTORS August 2, 2011 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Rd. P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Septic Upgrade for Cromwell Heights; Block 1, Lot 9 To whom it may concern: The existing 4 bedroom house is served by a private well and septic system. The septic system is in a state of failure and needs to be upgraded. Because of the extensive landscaping in the yard and newly constructed decks around the property, installing the alternate site would cause a significant amount of damage to the yard and decks. To avoid the damage we are proposing to rebuild the existing drainfield. The existing drainfield was installed in 1999 with 4.5 feet of separation to groundwater, at that time the MOA requirement for separation distance between the bottom of the drainfield and groundwater was only 4 feet in any given month. Groundwater was checked in June 1998 and was at 5.5 feet, requirements today seek for 5 foot separation from the groundwater for the month of June. We are proposing to raise the bottom of the bed to an elevation of 99.10 feet to meet 5 foot groundwater separation. We are unaware of/~ny adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. ~~' cerel~' ' Pres~en~ I 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com DESIGN CI~ITERIA: NUMBER OF BEDROOMS: 4 NOTE: THE CONTRACTOR GALLONS PER DA~ (GPO): BO0 GPD SHALL HAVE THE EAST PERCOLATION RATE/S: 2.5 MIN/INCH PROPOSED APPLICATION RATE: EASEMENT, AND ALL WELL M~N~MUM ORA, NFIE~ SQ.~.: 750 ' RADII FLAGGED BY A DRAINFIELD DESIGN: REGISTERED LAND SURVEYOR I MAXIMUM DEPTH: REMOVE CONTAMINATED SOIL PRIOR TO CONSTRUCTION. I WIDTH: 15 FEET LENGTH: 50 FEET M.O..A. APPROVED SAND FILTER: REMOVE ~, , CONTAMINATED SOIL AND IMPORT SAND TO AN I MOUND MUST BE TOPSOILED z, SEEDED J ELEVATION OF 99.2' EFFECTIVE: 0.50 ACTUAL SQ.FT.: 750 GEG, Ltd. HA~ A 7 PAGE SPECIFICATION THREE 1.25" PVC LATERALS O 48' LONG EACH LETrER THAT PERTAINS TO THIS DESIGN. 10 HOLES PER LATERAL (5'5' O'C')- 30 HOLES TOTAL I TO OBTAIN A COPY OF THE LETTER ,3/16" DIAMETER HOLES FACE DOWNWARD CONTACT GEG. BY PROCEEDING FORWARD WITH THIS INSTALLATION. THE ENGINEER. WELL DRILLER, CONTRACTOR AND ~ ~, ~'~': .~' ,? PROPERTY OWNER AGREE THAT THEY x ~,.¥,~.,-~:, .~'-.J~::-" ...,..x~ . HAVE READ THESE SPECIFICATIONS AND x ~ ~'" ~ ''~'~' '":' "'~ AGREE TO ACCEPT THE TERMS AND \ {,~:.<.,:'~:ir~- '~'~ ~ ~.~..~'.; CONDmONS OUTLINED. \ ' ,.?. ..... ' "~ ~ '~'" .- '..".,: · ., .'.... · ' .."' ,', ' "i'~ -k'_o ''~''s''~ ..:}' :L · . ;., .'f: ';. ,. ; .,... ,..., ,:; 'j ... . ~ ,, ~. ~ ,'~:.,:,; ...?; :: , · . . - ~ · o ,- · .. · .. \~.~ ~ - , . ~' .~:: '., i,-,:. :.: ,','. ,": ~".: i ;~.." :':'i," ' ':iv,, .~??;,Z,.'~;'"':" :": '""' '"'"':' ';' '~" *:'" ~'~"; ;" '"" BEOROOM EX,~,G ~ / "' ¢O~'~'~'XG~ON %~TI,G ~, 1500 TAN~ I . ...... % .ous~ 'rD .~- ~ ,. I / ,-.- PLACE. ~,~r.~-...--.~ I/~V ,__^ ,.",,,~ ,,~ TBM- BOTTOM OF SIDING. / ~.-/d;~-. ~kl,,~ t'"l::..' ~ .o-",~ &'~ X ELEVATION= 100.00 I 50'/ ! I --/..~- ~ ]u f Ollj J A HIGHER I I '",~"u..r..: ~, 'V_ r.,.~.C c~', r,,~,,",, ELEVATION. ' 1--,o. ' / · : .... 3701 E. PREP ...... I eft Garn ss LEGAL'~,. u~-~. ----~t-e~ / TYPE OF WOR~: DAf'E:.. SEPTIC DESIGN UPGRADE 8/10/11 · Municipality of Anchorage Page / of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~'V,/(~o~O,~ "/,~' PIDNumber: 01~-~-/0 Name:~U~S ~ y ~ ~O~ Wastewater System: ~ New D Upgrade Address: / ~ ~ O ~ ~/~ ~-~ ABSORPTION FIELD Phone: ~_~/~/ ~N°'°fBeT°ms: ~ Deep Trench ~ Shallow Trench .Bed DMound DOther LEGAL DESCRIPTION so,, Rating: O. ~ GPD/Sq. Ft .... Total Depth fr~originalgrade: Lot: ~ Block:/ ~o~Su~iv~i°n:~ ~/~ Depth to pi~ bo~omo. ~fr°m original grade: Ft. Gravel deptho.~neath~ pipe Ft. Township: ] Range: ~ Section:__ !F added a~ve original grade: Gravel length: Number of lines: ~ Disan~ ~n lin~: WELL: ~ New D Upgrade Grave~ width:/~ Ft. ~ ~ ~- ~ Ft. Clarification (Private, A.B,C): Total Depth: Cased To; Total absorption ama:~ Pipe material: ~1VA~ ~ ~t. ~ Ft. ~O ~ SO. Ft. Driller: Date Drill~: Static Water Level: Installer: Date installed:  Pump ~t at: ~ ~ing ~ight A~ve Ground: ~'*'~: & ~.~ ~d~d ~.l ~ ~- TANK SEPARATION DISTANCES ~ Se,tic ~ .o~ing To ~ptic Abso~tion Lift Ho~i~ Public/PHoto Manufacturer: ~pacity in gallons: From Tank Field S~tion Tank ~., Lin. ~E ~O~4 ~ ~A~ Sudace wat~ /~o+ /oo~ /o~ LIFT STATION Lot ~/ ~ / Size in gallons: I Manufacture~ Line ~ / ~/ /~00I Foundation I ?' J 3' 39, "Pump on" level a,:~ ,, j ..,u~, o,. ~v,, ,,:~ High water alarm at: Cu~ain Pump Make & M~I, ~ Electrical Ins~ions ~edormed by: Drain WO~ ~0~ -- )00~ 05~, ~. O. Remarks: BENCH MARK Location and De~ription: m ~um~ Elevation: Inspections pedormed by: ~ ~1..).r L~ ,--a, ~: 1st ?-~-~E ~~~'~'" ~e Rl~r, Ala~a ~5~ 2nd ?- 5o ~ , Depa~ment of Health and Human so.ices approval 72-013 (Re~. 9/91) MOA 25 PRimlT NO. SW980245 PAO~ 2 oF 3 H_.u Qi_.c i p. 9 I. i "i;. y._o. ? Anchor~ne DEPARTMEN/ UI-- HI-AL/H AND HUPTAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 e Anchorage, Ataska' 99519-6650 · TeLephone, 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LOT 9, BLOCK 1, CROMWELL HEIGHTS P.I.D. NO. 015--,552--10 SEPTIC 'RESERVE ~,"" j LOT 8 AREA :, r','l NEW' 1500 GAL. S.T.E.P. TANK ,P TIC AREA~ LOT 4 BED 1' PTIC ARKA'~ LOT 10 ROBERT C. COWAN CE - 8801 ':~,.,.', . .~': ....... PERMIT NO. SW980245 PAGE 3 OF 5 Municip. aLi~ o? .A~choraae DEPARTMENT OF HEA~_TH AND HuIvrAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 e Anchopage, Akask~ 99519-6650 · Telephone, 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LOT 9, BLOCK 1, CROMWELL HEIGHTS P.L9. NO. 015--552--10 ST1 99.3' 94.2~7 ST2 MH /ym~ NEW ~ 1500 GAL $.T,E.P. N.T.S. GRADE A 8 c FCO 52.5' , 20.5' - ST1 40.0' 28.5' - ST2 44.0' 55.5' - MT1 - 52.5' 78.0' MT2 - 27.5' 5g.0' MT2 .-msu~o~\ 1/101 .7' MTI '%08 15' .2' 93.6' WATER FOUND 90.0' BOH ~ec 2! 98 09:4~a p.~ Harle~ Sudsbur~ 696 1612 /--.~ SULLIVAN X l,En WELLS P.O. BOX 670272, CHUG~ ~ 99567, ~PH~E 688-2759 OWNER OF LAND LEGAL DESCRIPTION PERMIT NUMBER~ Date of tssue~-~.~. T~ iNDENTIFICATION NUMBER Is well Io~ at approv~ ~ Io~tion? '~ ~ No Method of Drilling: ~Pth of well: Casing Ty~ ~~11 Thinness , ~0 inches Diameter in.es, depth., ~ feet ~ner Type:_ ~'~ Casing Stickup Above G~nd: ~ ~ ~ feet S~tic Water Level (from gmu~:level):. }~ .. feet Pumping level:, f~t affe~hm, pumping ~pm Re~ver Rate: ~ _g~. Meth~ of Testing: Well Intake O~ning T~: ~n End ~ Open Hole ~ Scmen~; S~ f~t Stopp~ ~t ~pth: ~m.. ~ _~t, to ~ ' .feet Pump ln~ke ~pth: f~t Pump Size hp Brand Name Well Disinfect~ Upon ~pletion? ~s ~ No BORE HOLE DATA ,tT, toO. Ci, FI~. JAN 26 1999 Method of Disinfection: ~..~ A~ENTION: It is ~e ~nsibili~ of t~ pm~ owner to submit a ~py of the ~11 log to ~e ~r a~he~. Mun~ipal~ ef An~omge: ~~nt ~ Health & Human Sewices an~or Depa~ment ~ Envimn~n~i Collation. MatSu Bom~h: Depadment of Envimnmen~l Con~wation. anee m 'ROBERT C. COWAN, RE. ROBERT A. SHAFER, RE. Date: CIVIL ENGINEERS FAX (~07) 694-1211 I"IE/~TH AUTHORITY APPI~)VAI.~ 8EWER & WATER MAIN EXTEI~IONS SEWER & WATER INSPECTION ENGINEERING STUDIES NqD REPORTS WELL INSPECTION & FLOW TEST SJTE PLANS ROAD DESIGN SOIL TEST PERCOLATION TEST STRUCTURAL & ME~ I~I~PECTIONS ON~ITE WASTE'WATER E~d~'~. SY6TEM Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 L Street P.O. Box 196650 Anchorage, Alaska 99519-6650 RECEIVED AUG $1998 D Municipali of epL H ~.~. ~. . Anchora REFERENCE The septic ingpec~ions for the ~eferenced property were performed on'7/~/~? and D/~/q~. Prior to submitting the On-site Wastewater Disposal System ~nd/or Wel/Inspection Report we are waiting for the~$8, ur Nv&v,y/~~o be completed. If we may be of further service please contact us. Sincerely, ~? n, P.E. 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date Issued: Jul 16, 1998 Expiration Date: Jul 16, 1999 Permit Number: SW980243 Legal Description: CROMWELL HEIGHTS BLK Design Engineer: S & S Engineering Owner Name: Sudsbury & Sons Owner Address: 16906 Riddell Eagle River, AK 99577- 1LT 9 Parcel ID: 015-332-10 Site Address: 011000 PHILLIPS ST Lot Size: 28800 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ~-] Disposal Field [~ Septic Tank r-] Holding Tank [] Privy Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours pdor to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. An additional soils pemolafion test shall be performed according to EPA guidelines at the time of construction Received By: '"~'~Z ~______--~--lv~. Date: 7-'Z°-a/~ ROBERT C. COWAN, RE. ROBERTA. SHAFER, RE. June 29, 1998 CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 HEALTH AUTHORITY APPROVALS SEWER & WATER MAIN EXTENSIONS SEWER&WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOILTEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SITE WASTEWATER DISPOSAL SYSTEM DESIGN MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 9, Block 1, Cromwell Heights Subdivision Request you issue a permit to install a septic system and well to serve the'~four bedroom house on the referenced property. A test hole was excavated and percolation test performed. The approximate location of the test holes are located on the attached site plan. At thc time of excavation 6/1/98 water was encountered in the test hole. After seven days the ground water monitoring tube reflected that water was found at 5.5 ft. We do not anticipate any adverse effects on neighboring wells, septic systems, , or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on any of the adjacent properties. We request you expedite the issuance of this permit due to the unsanitary conditions. If you require additional information, please contact us. Sincerely, RCC/mg Enclosure 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 Municipality of Anchorage. DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: -,c~)/v J cow . 2;-1 DATE ............... Township, Range, Section: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O WAS GROUND WATER ENCOUNTERED? SLOPE SITE PLAN IF YES. AT WHAT DEPTH? Delah to Water Nt~r Monitering? Date: Reading Date Gross Net Depth to Net Time Time Water Drop .. ~/,/~y /o';ti -_' ~v~.,, _ t0 '. ~-/ - ~' '%,' -- /0 ', ~ - ~--'/~" - ~0 '~ - ~ '~z" -- l/~ ~o s~ ~,~ ~',~" 2" PERCOLATION RATE~ ~' ~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ ~/~*~ ~ '/,~ FT AND FT COMMENTS PERFORMED BY:. ........... ~,;,~=~ ,~ ~.,.~ I ACCORDANCE vrI~I~I~i~ltI~I~II~i~I~PAL GUIDELINES IN EFFECT ON THIS DATE. 72-~8 (R~. 4/~) .~ CERTIFY THAT THIS TEST WAS PERFORMED IN DATE: ROBERT C. COWAN, RE. ROBERT A. SHAFER, RE. HEALTH AUTHORITY APPROVALS SEWER & WATER MAiN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOIL TEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SITE WASTEWATER DISPO~AL SYSTEM DESIGN ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 REFERENCE: Lot 9, Block 1, Cromwell Heights Subdivision June 29, 1998 GENERAL: The scope of this project includes the installation of a 1500 gallon wastewater S.T.E.P. system (septic tank) and a pressurized absorption bed to serve the proposed four bedroom residence located on the referenced property. Construction shall be in accordance with the approved site plan and design drawings; Municipal permit with any special provisions or conditions; and all applicable State and Municipal Wastewater Disposal Regulations. o The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed fi:om soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval fi:om the Municipal Health Department. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shilling of the tank. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 page Two Lot 9, Block 1, Cromwell Heights S/D June 29, 1998 4. Septic tanks installed with less than 4 fi. of cover shall be insulated. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. LEACHFIELD BED INSTALLATION: Excavate the proposed Bed Area to the depth shown on the design. The bottom of the excavation shall be within 2 inches of level. If the bottom of the excavation becomes smeared, it must be raked or scratched (ruffed-up) before gravel or sand placement. If a sand layer is required, place sand over entire excavation to the required depth shown on the design. The top of the sand layer must be within 2 inches of level. Sewer rock shall be placed uniformly throughout the entire bed. The distribution piping is to be ofPVC (ASTM D3034 or equal). All joints are to be solvent cemented. Gravel depth below the distribution pipes shall be a minimum of six (6) inches. Gravel depth above the perforated pipe shall be a minimum of two (2) inches. The distribution piping must be as shown on the design. The distance between the outermost perforated dislribution pipes and the sidewall of the absorption bed must be no more than three feet. o Silt barrier material must be installed between the final gravel layer and the native soil backfill, unless insulation is used, then the silt barrier should be installed over the insulation. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter, installed at the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel depth shall be perforated six (6) inches below the bottom of the horizontal distribution lines. The monitoring tube should not extend below the bottom of the gravel surface. , ! Page Three Lot 9, Block 1, Cromwell Heights S/D June 29, 1998 MINIMUM MATERIAL SPECIFICATIONS: Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finished grade over the bed must be mounded to prevent the formation of a depression after settling. Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the//200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements, which ever specifications applies. Page Four Lot 9, Block 1, Cromwell Heights S/D June 29, 1998 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER CERTIFICATE FOR A Parcel I.D. 015-.352-10 1. GENERAL INFORMATION Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 OF ON-SITE SYSTEMS SINGLE FAMILY APPROVAL DWELLING COSA# Expiration Date: !./' ,~ ~ -// Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency CROMWELL HEIGHTS; BLOCK 1, LOT 9 11000 MOUNTAIN LAKE DRIVE *ANCHORAGE, AK 99516 JEFF LEONARD 11000 Day phone 440-8040 MOUNTAIN LAKE DRIVE *ANCHORAGE, AK 99516 Day phone Mailing address Real Estate Agent ~.. Mailing address Unlessothetwi~:.requested, COSA will be held by DSD for pickup. 2...NUMBEROF BEDROOMS: 4- BARBARA MICHELSON W/ PRUDENTIAL Day phone 5801 CENTERFIELD DRIVE *ANCHORAGE, AK 9950.3 250-5577 TYPEOFWATER SUPPLY: Individual Well · Individual Water Storage [] Community Class Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professiOnal civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the vafidation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address ,3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Phone 357-6179 Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE Approved for bedrooms. ~: 0N-SITE Disapproved. ~ · ~ STEWATER Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory (Rev. 11/05) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: ~- ~. LC.. / / CERTIFICATE Legal Description: CROMWELL HEIGHTS; WELL DATA Well type PRIVATE Date completed 8/1 2/98 Total depth 96 ft. Date of test Static water level 34 Well production 6 WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi. Arsenic: NB ug./L. SEPTIC/HOLDING TANK DATA Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 OF ON-SITE SYSTEHS APPROVAL BLOCK 1, LOT 9 If A, B, or C provide PWSID# Sanitary seal (Y/N) YES Cased to 96 ft. FROM WELL LOG 8/12/98 N/A g.p.m. Nitrate 0.16 mg./L. Date of sample: 7/27/11 Tank Type/Material STEP/STEEL Tank size 1500 gal. Number of Compartments 2 Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO Dateofpumping ~/O~/[I Pumper AfOM, ftcJ '7-~ ~. ABSORPTION FIELD DATA I'BELOW FINAL GRADE I Date installed 8/'18-19/11 Soil rating (g.p.d./ft~or~ 0.8 Length 50 ft. Width 15 ft. Total depth *2.72+ ft. Date of adequacy test Fluid depth in absorption field before test - in. Elapsed Time: - min. Final fluid depth - Any rejuvenation treatment (past 12 mo.) (Y/N & type) Eft. absorption area 750 ft2 Monitoring tube NEW Results (Pass/Fail) PASS CHECKLIST Parcel ID: 015-332-10 Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION 7/27/11 23 ft. 5.6 g.p.m. YES 24 in. YES Collected by: GEG, Ltd. Water added - in. Date installed 7/29/98-1/14/99 Cleanouts (Y/N) YES High water alarm (Y/N) YES gal. NONE Absorption mte>= KNOWN System type BED .Gravel below pipe 0.53+ YES Depression over field NO For 4- bedrooms New depth - in. 600+ g.p.d. If yes, give date - D. LIFT STATION Date installed "Pump on" level at__ in. Size in gallons Manhole/Access (Y/N__N.)_ "Pump off" level~at~. High water alarm level at Cycles tested. Meets alarm & circuit requirements~ SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: 100'+ Septic tank/lift station on lot Absorption field on lot 100'+ Public sewer main N/A Sewer/septic service line 25'+ Animal containment areas. 50'+ in. On adjacent lots 100' + On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding tank N/A Manure/animal excrete storage areas 100'+ F= Water service line Curtain drain NONE COMMENTS SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5' + Property line 5' + Water main N/A Water service line. 10'+ Wells on adjacent lots 100' + SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 1 o'+ Surface water 1 o0'+ KNOWN Wells on adjacent lots 100'+ Absorption field Surface water 5'+ 100'+ N/A Driveway, parking/vehicle storage 10'+ G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Na~ne JEFFREY A. GARNESS Date (~ /'7.. ~ / ~ll cos^ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number ,00'091, =1,,00,90o0 10' UTILITY EASEMENT 40,4 220 ,00'091, /V~,,OO,GOoO N MOUNTAIN LAKE DRIVE MUNICIPALITY OF ANCHORAGE *DEPARTMENT- OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # 1, GENERAL INFORMATION Complete legal description CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 015-332-10 HAA # ~-~1 ~'~ Lot 9, Block 1, Cromwell Heights Location (site address or directions) I~ oo Mountain Lake Drive Property owner Mailing address Jeffrey & Shawna Leonard Day phone 522-4139 1100 Mountain Lake Drive, Anchorage, AK 99516 /"Lending' agency Alaska USA/Jan/Shannon Coleman Mailing address ao(3o cr,~a{ ~- .n{ nn ~{ w~ An~hnr~0~ Day phone 786-2800 Agent Day phone Address Unless otherwise requested, HAA Will be held for pickup. 4 NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well community well Public water NOTE: If community well system, provide written confirmation from State.ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site NOTE: Holding tank Community on-site Public sewer If community wastewater system, provide, written confirma!ion from State ADEC attesting to the legalitY and status of system. 72-025 (Rev. 1/91) Front MOA #21 STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application Shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date~ of this inspection. Name of Firm S & $ ENGINEERING iYO~,i Eagie ~Iver Loop ~<ead No. ';'uq Phone ~ ~/~ _ ~_ r~ -7 ~/ Address Eagle River, Alaska 99577'., J SIGNATURE Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments By: The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or. ana!yz~,data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's wOrk. 72-(325 (Rev. 1/91) Back MOA #21 Municipality of Anchorage R E C E IV DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division JAN 2 7 199 825 L Street, Room 502- Anchorage, Alaska 99501-(907)~3u4~(~ATL~~ o~ ^NCHO~AGE Health Authority Approval Checklist LegalDescription: Lo~- ~ '~-¢c,c / ¢~~ I~r J ParcelI.D.: 01~--~ ~ -/0 A. WELL DATA Well type ~o/~ ~v/~. T~ IfA, B, crC, attach ADEC letter. ADEC water system number present[C~N),~x. ¥ ~ -~ Date completed ~ / / -z. ! ci ~ Log Total depth c~ G Cased to ~ ~ Sanitary seal ~/N) ~ .r FROM WELL LOG Date of test ~' / ~ ~ / '~ ~ Static water level Well production /o g.p.m. Casing height (above ground) Wires properly protected (~N) AT INSPECTION WATER SAMPLE RESULTS: Coliform O Nitrate ~' ('' .C ~' Other bacteria Date of sample: ~'/ / 7 ~/¢{~ Collected by: ~ '~ ~' B. SEPTIC/HOLDING TANK DATA Date installed w ! 3 o / ~ ~' Tank size Foundation cleanout ~/N) Y'//fl' Date of Pumping /v//~ -,v,~,,. / 5-o o Number of Compartments '3- Cleanouts (~/N) ¥ 4 £ Depression (Y/I~ ~a High water alarm ~/N) ¥,~ .r Pumper C. ABSORPTION FIELD DATA Date installed '~//~o / ¢~ ~ Length 3~' 0 Width Soil rating ~or fF/bdrm) ~?- ~' System type /~ ~- O ! 5- Gravel thickness below pipe (.0. ~ Total depth ~ ~/~-- Effective absorption area "75-o )~r '~Monitoring Tube present~/N). ¥'~ J Depression over field (Y/~) Date of adequacy test '~/"~ -_ '" ~"~' Results (Pass/Fail) _ _-FerZ_ ~' Fluid depth in absorption field before test (in.); ~,~~r__ gal. water added (in.): Fluid depth ~ (ins~ Absorption late =_ .g.p.d. Peroxide treatment (p months) (Y/N) If yes, give date 72-026 (Rev. 3/96)* bedrooms LIFT STATION Date installed '~ I 3,3 Manhole/ACcess ~)'N) High water alarm level at* Cycles tested E. SEPARATION DISTANCES Size in gallons "Pump on" level at* ~ .3 *Datum ~ o ~- T ~ ,~ "Pump off" level at* SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field on lot Public sewer main Sewer/septic service line On adjacent lots On adjacent lots Public sewer manhole/cleanout Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation ! q Property line '~ ~,, Absorption field Water main/service line )o .t Surface water/drainage JO 0 4- Wells on adiaeent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line Surface water Curtain drain Building foundation I '5 Water main/service line Driveway. parking/vehicle storage area o ~,, ,.~ Wells on adjacent lots ] o 0 ENGINEER'S CERTIFICATION I certify that I have determined thru field inspections and review of Municipal ..... in conformance w, th MOA. HAA guidelines ,n effect on th,s date. Engineer's Name A. ~/J a ~ ~ ~ . ~o ~ ~ ~ Date I/ ~ ~ / ~ ~ HAAFee $ '~D'-D ' ~ Date of Payment Receipt Number Waiver Fee $ Date of Payment Receipt Number 72-026 (Rev. 3/96)*