HomeMy WebLinkAboutCOLONIAL PARK BLK 4 LT 12A
QGREA E:R ANCHORAGE AREA BORC',JGH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME Executive Realty
Eagle River
LOCATION C~l ~n~ ~ ] Q~r~
MAILING ADDRESS 2810 C Street PHONE
· q~3_b~V~onLEGAL DESCRIPTION Lot !2A Block 4
276-7777
SEPTIC TANK:
DISTANCE NUMBER OF
FROM WELL N/A MANUFACTURER Sunset Plasti~TERtAL Fibreglass COMPARTMENTS two
Inc.
INSIDE LENGTH 7 ' -8" INSIDE WIDTH 5 ' -2" LIQUID DEPTH. 4 ' -i'L~QU~D CAPACITY 1000 GALLONS.
SEEPAGE E[~'A Trench
NUMBER ohs
LINING MATERIAL . N/A
BUILDING FOUNDATION 20
ADDITIONAL ABSORPTION
DIAMETER N/A OR WIDTH_2_~_, LENGTH_2_8,' DEPTH 12
CRIB SIZE: DIAMETERN/ADEPTH ~q/A DISTANCE FROM: WELL
TOTAL EFFECTIVE
NEAREST LOT LINE_2_5~__ . ABSORPTION AREA (WALL AREA) 480
N/A
SQ. FT.
WELL: Community System located to the West approximately
TYPE CONSTRUCTION Drilled - Cased DEPTH
BUILDING NEAREST NEAREST SEPTIC
FOUNDATIONN/A , LOT LINE ~/A , SEWER LINE N/A , TANK
CESSPOOL ~/A , OTHER SOURCES
APPROVED DISAPPROVED REMARKS
450 feet.
DISTANCE FROM:
SEEPAGE
SYSTEM N,/A
DISTANCES:
INSTALLED BY: Maus
Excavating
PIPE MATERIAL: PVC
LOT SLOPE: Level
REMARKS:
Form No. EQ~031
DIAGRAM OF SYSTEM
DATE 11/23/76
APPROVED
~AAY~ Mgening-~rey &
Associates, Inc.
PERMIT
MUN I [: I ~:'AL I T~" OF ANCH~-~RAGE
DEPARTMENT HEALTH AND ENYIRONMENTAL ,~OTECTION
2510 E. YUDOR RD., ANCHORAGE..
ON--SZTE 5ENEE PEE~ZT
76i~7 )
APPLICANT
LOCATION
LEGAL
EOREMOST__SERVICE~_ 25a~ BROOKWOOD
E. R. RD
Li2R B4 COLONIAL PARK SUBD LOT SIZE
278-3644
ti719 SQUARE FEET
TYPE OF SOIL ABSORBTION SYSTEM IS: TRENCH
MAXIMUM NUMBER OF BEDROOMS
SOIL RATING
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS:
DEPTH= 12 LENGTH= 21 GRAVEL DEPTH=
THE LENGTH DIMENSION IS THE LENGTH (IN FEET> OF THE TRENCH OR DRRINFIELD.
THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET>.
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE
RND THE BOTTOM OF THE EXCRVRTION (IN FEET).
REQU I RED SEPT I C TANK S I ZE= ieee OALLOt~5
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCE BETWEEN R WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM I$
iAe FEET FOR R PRIVATE WELL OR 288 FEET FOR R PUBLIC WELL.
SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER
INSTALLATION.
PERM I T YAL I D FOR ONE YEAR FROM I $SLIE
I CERTIFY THAT
i: I RM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
IF THE
2204 Cleveland Anchorage, Alaska 99503'
'Foremost Construction Date Performed
4/21/76
Performed For
Leaal ~escrinti'on: lot 12A_B10¢k 4 Subdivision Col_on,al ~rk Subd. Eagle River
This Form Reports Soils hoa Percolation Test
Peoth
.fi, Fee t To~, s,o.i~O i 1 iCha,racteristi cs
Sandy Gravel
($P-~W)
m
10--
12--
14--,
16
Brown Gravelly Sand
(SP-SW)
18 - -
Bottom of test hole
No ground water ,or b~drock
encountered
Was Ground Water Encountered?,
I~ Yes, At what Depth?
Readinq
Date
Gross Time
Net Time
Depth to H20
Net Drop
Percolation Rate llinute
Prnposed Inst~'l'ta'tio~: Seenaae Pit Drain Field
Depth of Inlet Depth ~ Bot----~om Of Pit O~ 'Trench.
~AMI~ENTS:~ feet draina~~2L-~
~':[ i~,~o~m~ B~ ~//~a~me~s Dat:a Cerl~ified Bg: CONSTRUCTION TEST
-- O, Ma"c~ --- D~te; ~/23/~~6
MOENING-GREY & ASSOCIATES, INC.
GEOLOGISTS AND ENGINEERS
715 i STREET, SUITE 8 ANCHORAGE, ALASKA 99501
TELEPHONE 274-2314
December 2, 1976
~unicipality of Anchorage
Dept. of Health and Environmental Protection
2510 E. Tudor Road
Anchorage, Alaska 99507
Attention: Mr. John Kennedy
Re:
On Site Sewage Disposal, Lots llA, 12A, 13A, & 14A,
Block 4, Colonial Park Subdivision in Eagle River.
Gentlemen:
As reported to you by telephone this morning, the depth of
screened gravels in the seepage trenches on the subject
Lots is as follows:
Lot llA - 9 feet
~Lot 12A - 9 feet
Lot 13A - 8 feet
Lot 14A - 8 feet
Please call if you require further information.
Very truly yours,
MOENING-GREY & ASSOCIATES, INC.
~_.(~ C-'~.) ,.~_.-w.....7;,~.x /.~'l ,
HJM/lv
DA~E RECEIVED
INSPECTION APPOINTMENTS
TIME TIME TIME ' ~),C~
DATE DATE DATE
INSPECTOR INSPECTOR INSPECTOR
MU NICI PALIT~(~N~P-AGE
DEPT. Of HI:'~LIM
~UNIOIPALITY OF ANOHOHAGE ENVIRONMENTAL
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
825 L Street-Anchorage, Alaska 99501 ~Y ~ 3
ENVIRONMENTAL SANITATION DI VISION
Telephone 264-4720 RECEIVED
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
DIRECTIONS: Complete all parts on page 1. Incomplete reques~ will not be proce~ed. Please allow ten (10) days for processing,
;1. PROPERTY OWNER PHONE
MAI LING ADDRESS
PROPERTY RESIDENT (If diff rom above) PHONE
2. BUYER PHONE
MAI LING ADDR ESS
3, LENDING INSTITUTION PHONE
MAI LING ADDRESS
4. REALTOR/AGENT PHONE
MAILING ADDRESS
5. LEGAL DESCRIPTION
;TREET LOCATION
6. TYPE OF RESIDENCE NUMBER OF~BEDROOMS
[] One [] Four
~-~L~ SINGLE FAMILY [] Two [] Five
[] MULTIPLE FAMILY ~ Three [] Six
[] Other
7. WATER SUPPLY [] INDIVIDUAL*
COMMUNITY
[] PUBLIC UTILITY
* ATTACH WELL LOG. A well Icg is required for all wells drilled
since June 1975. For wells drilled prior to that date, give well
depth (attach Icg if available.)
8. SEWAGE DISPOSAL SYSTEM
INDIVIDUAL/ON-SITE~
[] PUBLIC UTILITY
YEAR ON-SITE SYSTEM WAS INSTALLED.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010 (Rev. 6/79)
THIS SIDE FOR OFFICIAL USE ONLY
1, TYPE OF RESIDENCE
[] SINGLE FAMILY
[] MULTIPLE FAMILY
2. WATER SUPPLY
[] INDIVIDUAL
[] COMMUNITY
[] PUBLIC UTI LITY
Connection Verified
3. SEWAGE DISPOSAL SYSTEM
[] IN DIVI DUAL/ON -SITE
[]PUBLIC UTILITY
Connection Verified
[~]Septic Tank or [] Holding Tank
Size: If Tank is homemade
give dimensions:
NUMBER OF BEDROOMS
[] ONE [] THREE [] FIVE
[] TWO [] FOUR [] SIX
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
PERMIT NUMBER
DATE INSTALLED
INSTALLER
SOl LS RATING
TYPE OF TANK MANUFACTURER
TOTAL ABSORPTION AREA MATERIAL
4. DISTANCES
WELL TO:
Absorption Area to nearest Lot Line
[] OTHER
Septic/Holding Tank
IAbsorption Area lSewer Line
Nearest Lot Line
5. COMMENTS
~ APPROVED FOR ,.~ BEDROOMS
[] CONDITIONAL APPROVAL (letter must accompany certificate)
[] DISAPPROVED
DATE
BY
72-010 (Rev. 6/79)
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PJii~PERTY, OI/~NER ....... PHONE
MAILING ADDRESS ' ' ' ° '
PROPERTY R~SIDfiNT (If different from above) ~ PHONE
2, BUYER
3, LENDIN6 1~STITOTION ' ' [ PHON~
MAILING ADDRESS J / ' J
6. TYPE OF RESIDENCE
~ SINGLE FAMILY
[] MULTIPLE FAMILY
7. WATER SUPPLY
[] INDIVIDUAL*
COMMUNITY
[] PUBLIC UTILITY
8. SEWAGE DISPOSAL SYSTEM
INDIVIDUAL/ON-SITE**
[] PUBLIC UTILITY
NUMBER OF BEDROOMS
[] One [] Four [] Other
[] Two [] Five
Three [] Six
* ATTACH WELL LOG. A well log is required for all Wells drilled
since June 1975, For wells drilled prior to that date, give welt
depth (attach log if availab e,)
**If individual/on-site, give installation date ~C~"~/o .
If system is over two (2) years old an adequacy test is required
by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010(3/78) ' '- '
THIS SIDE FOR OFFICIAL USE ONLY
DATE RECEIVED
INSPECTION APPOINTMENTS
TIME TIME TIME
DATE DATE DATE
INSPECTOR INSPECTOR INSPECTOR
DIRECTIONS:
1. NUMBER OF BEDROOMS
TYPE OF RESIDENCE
[] SINGLE FAMILY
[] MULTIPLE FAMILY
[] ONE [] THREE [] FIVE
[] TWO [] FOUR [] SlX
[] OTHER
2. WATER SUPPLY
[] INDIVIDUAL
[] COMMUNITY
PUBLIC UTILITY
Connection Verified
3. SEWAGE DISPOSAL SYSTEM
[] INDIVIDUAL/ON -SITE
[]PUBLIC UTILITY
Connection Verified
[]Septic TanJ~ or []Holding Tank
Size: t(~ ~ If Tank is homemade
give dimensions:
TYPE OF TANK
TOTAL ABSORPTION AREA
4. DISTANCES
WELL TO:
Absorption Area to nearest Lot Line
5. COMMENTS
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
PERMIT NUMBER
DATE NSTALLED
INSTALLER
SO~ ,LS~RATI N G
MANUFACTURER
MATERIAL
Septic/Holding~Tank
IAbsorption Area lSewer Line
Nearest Lot Line
[] CONDITIONAL APPROVAL (letter must accompany.~7~r-t~cate)
[]~ DISAPPROVED
LEGAL DESCRIPTION
72-010 (Rev. 3/78)
DAVID A. SLENKAMP
ROBERT A. SHAFER
MECHANICAL ENGINEER
694-9055
August 27, 1980
CIVIL ENGINEER
694-2979
MUNICIPALITY OF ANCIIORAGL:
DEPT. OF ',i Li;! &
ENVIRONM[!Ni,,,L , , ~;:CrlON
Mr. David Hendricks
2720 First Street
~Rle River, Alaska
99577
RECEIVED
Dear Mr. Hendricks,
Reference: Lot 12fl; Block 4; Colonia} Park Subdivision
A sewer system ndequacy test was performed on the system located
on the referenced property per your reauest. The septic tank
was pumped and verified to have a capacit~f of approximately 1000
ga'ilons. The absorption trench vms checked by charging the s~fstem
with a continuous flow of approxim~tely 706 gallons over a period
of 2Y~ hours.
It can be concluded from this test that the se~mge system and
absorption trench is currently functioning adequately :for your
three bedroom residence.
If we may be of further assi~tgnce, pleurae do not hesitate to call.
Sinc er ~]~¥, / .//
.gFE E
/ cc: Munici~al~t~ of Anchorage
Department of He.~lth and Enviornmental Protection
Totem Realty
ATrE;~TION. L~urie Long
Alaska State [~nk
SRB 196X EAGLE RIVER, ALASKA
MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION DEPT. OF H~AI. TH &
825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL P~OTECTION
ENVIRONMENTAL ENGINEERING DIVISION mUG 8 1979
Telephone 264-4720
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEV~_L~_ ~iL~,~
DIRECTIONS: Complete all parts on page 1. Incomplete reques~ will not be processed. Please allow ten (10) davs for processing.
1. PRO~TY OWNER PHONE
3. ~e~NST~TUT~O~ ~ il / ~ . I.~ ~ . ~ -/) ~ I ~NE
· .~ ~ ' ,
: I '
L
/ / ·
IS. LE~tJ. DE.~CfllPTION
I STR EE~L~A~C3
S. TYPE OF RESIDENCE
~'~ SING LE FAMILY
[] MULTIPLE FAMILY
NUMBER OF BEDROOMS
[] One [] Four
[] Two [] Five
~ Three [] Six
[] Other
7. WATER SUPPLY
[] INDIVIDUAL*
~ COMMUNITY
[] PUBLIC UTILITY
' 8. SEWAGE DISPOSAL SYSTEM
INDIVIDUAL/ON-SITE**
* ATTACH WELL LOG. A well log is required for all wells drilled
since June 1975. For wells drilled prior to that date, give well
depth (attach log if available.)
**If individual/on-site, give installation
If system is over two (2) years old an adequaL"~ test is required
[] PUBLIC UTILITY by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010(3/78) ~ ~
THIS SIDE FOR OFFICIAL USE ONLY
DATE RECEIVED
I NSPECTI ON APPOI NTM ENTS
TIME TIME TIME
DATE DATE DATE
INSPECTOR INSPECTOR INSPECTOR
DIRECTIONS:
NUMBER OF BEDROOMS
1. TYPE OF RESIDENCE
al;;~"~i NG LE FAMILY
[] MULTIPLE FAMILY
2. WATER SUPPLY
[] INDIVIDUAL
E~(~MMUNITY
[] PUBLIC UTILITY
Connection Verified
3. SEWAGE DISPOSAL SYSTEM
[~14~!1~1~i D UA L/O N -SITE
[]PUBLIC UTILITY
Connection Verified
r--ISeptic Tank or [] Holding Tank
Size: /~)~3(~) If Tank is homemade
give dimensions:
TYPE OF TANK
TOTAL ABSORPTION AREA
4. DISTANCES
WELL TO:
Absorption Area to nearest Lot Line
[] ONE [] THREE [] FIVE
[] TWO [] FOUR [] SlX
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
PERMIT NUMBER
DATE INSTALLED
INSTALLER
SOILS RATING
MANUFACTURER
MATERIAL
'Septic/Holding Tank IAbs0rption Area
I
[] OTHER
~lO
I Sewer Line I Nearest Lot Line
5. COMMENTS
~ APPROVED FOR ~ BEDROOMS
[] CONDITIONAL APPROVAL (letter must acco/~__~ny
[--I DISAPPROVED //
DA TE B Y/~ e)
LEGAL DESCRIPTION
certificate)
72-010 (Rev. 3/78)
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
1. Approval requested by:
Mailing Address: 645
2. Property Owner:
Mailing Address:
3. Legal Description:
4. Location:
5. Type of facility to be inspected
6. Well Data:
A. Type Community
C. Construction
7. Sewage Disposal System:
A. Instal]ed
C. Septic Tank:
D. Seepage Pit:
E. Disposal Field:
e
Date Received November 10, 1976
Time of Inspection
Date of Inspection
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
Conv.
United Bank Alaska % Matt Sullivan
G Street Phone: 278-9526
Roger Fielder Phone: 694-9894
Lot 12A,Block 4 Colonial Park Subdivision
First Street
Sinqle Family
B. Depth
No. of bedrooms 2
D. Bacterial Analysis
On-site system
1976 B. Installer /]~ ~
l. Size ~ 2. Manufacturer
1. Absorption Area ~ 2. Material
Total length of lines
, Absorption area
, Other contamination
, Absorption area
Distances:
A. Well to: Septic tank
Nearest lot!ine
B. Foundation to septic tank
C. Absorption area to nearest lot line
, Sewer Lines
EQ-034 (1/74) Page 1 of two pages
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
2510 East Tudor Road, Anchorage, Alaska 99504 276-2221
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
1. Type of Inspection: CMRO VA FHA
3. Name of Buyer:
Mailing Address:
4. Name of Lending Institution:
Mailing Address: Phone:
5. Name of Realtor or Agent:
Mailing Address:
7. Type of Facility to be Inspected:
No. Bdrms. ~
8. Water Supply
Type of Supply: Public Utility
Individual
If Individual, number of dwellings presently served
If Individual, depth of well.
Sewage Disposal System
Type of System: Public Utility
If Individual, date of installation
Individual (on-site)
72-003(3/76)
'Page 2 of two pages - Req~ t for Approval of Individual Sc '- & Water Facilities
Leg'al Description Lot 12A Block 4 Colonial Park Subdivision
~p~ov~d ~ ~~ Disapproved
Date//'- ~- ~(~,
Approval Valid for one year from date signed
Greater Anchorage Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
I certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED ~ Date
EQ-034 (1/74)