HomeMy WebLinkAboutCONIFER HEIGHTS BLK 1 LT 9 Municipality of Anchorage DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION POUCH 6-650 ANCHORAGE, ALASKA 99501 INSPECTION REPORT ON ONSITE SEWAGE DISPOSAL SYSTEM AND/OR WELL PERMIT NUMBER ADDRESS ~[ ~~~E~ ~~LEGALDESCRiPTiON ~ PHONE(S) ~- ~0 ~ ~ ~ ~l~t~~O ~OFBEDROOMS SEPTIC TANK MANUFACTURER Lkl~:~'T' CAPACITY IN GALS. MATERIAL ~-~)e~CCoL. R5 #OF COMPARTMENTS INSIDE DIMENSIONS LENGTH WIDTH DEPTH ~,. SEEPAGE SYSTEM [] TILE DRAINFIELD NUMBER OF UNES LENGTH ·EACH TOTAL LENGTH DISTANCE BETWEEN LINES TRENCH. WIDTH TILE TO GRADE FILL BELOW TILE FILL ABOVE TILE ~SEEPAGE TRENCH OR ~ PIT WIDTH ~/~ LENGTH ~ DEPT"~I~ ~ ~ ~/LOG CRIB ~ RINGS- DIA. FILL MATERIAL DEPTH ~ TOTAL EFFECTIVE ABSORPTION ARE~; ~ S~ FT, WELL CLASSIFICATION DEPTH PIPE MATERIAL INSTALLER DATE j~~. 72-012 (9/77); APPROVED 8 ~,.~. ~ DISTANCES  SEPTIC SEEPAGE SEWER TANK SYSTEM LINE CESSPOOL WELL WELL SYSTEM DIAGRAM LOT: PERMi"f' NO. APPI... I C;ANT MS SH i RL..EY HEN[:,ERSOr.i_ I..,.OC A']' ]: C31'.,I PC)F.'.T CIRF I]RI]:, LEC. iFII_ LO]" 9 BL .1 CONIFER HEIGHTS SUB LOT SiZE 'TYPE OF SOIL FIBSORBTION SYSTEM IS: TRENCH MAX I MUM NUMBER C)F BEDROOMS = 4 qO I L RAJ" I NG ,:'. SQ F]",.."E:R ::, = THE: RE6!LIIRE[:, SIZE OF' "I'HE SOIL FIBSORPTION '.S'T'S]"FM It';:· i].':, [-] F' ""IF H = :]1_ ~E~ L. EZ I'-4 ,.Ti T' H = 4 4 ii ti.'. A %-' E:: I ....... [:, E-: F' 'T' t--tl = ~i; THE LE:NG"I-H DIMENSIC)N I S 'I"HE LENGTH ( IN FEET) OF "f'HE TRENCH OR DRFIINF'IEI...[::,. THE DEPTH OF FI TRENCH OR F"[]' I':;; THE DIS'f'FINCE BE'f'HEEN THE SUF..:F'FICE OF THE GROUND FIND THE BO'f'TC)M OF THE E~3:::FIvFr'I"ION (iN FEET). ]'HERE .I.:..:, NO SE'I' HI[)]"'HFut,.' '-1REN...HE5."'- I ........... T'HE C3RFIVEL. DEP"I'H I::2; THE MINiMI..IM DEPTH OF' GRAVEL BD'f'WEEN THE OU'I"FALL PIPE AND THE 801"'f'OM (DF THE E]:.:'.C:AVATION (IN FEET). F~ A [7-: I-::: A ~:]i FZ F" I1_.. A I%t -I- i3 F' ""11"' ][: Ci I%11 FI PF/C:KFICiiE PL. FINT' MFIY BE INS'['ALLED FI'I .... I"HE PERMI'I"TEE'"S OPTION SUB..IEC'f' TO THE FOL. L_OW I NG COND i T l ONS: · 1.. EITHEF.: FI CL~FISS I OF.'. I I NSF' FIPPROVE[:, PL~RNT MFIY BE I NSTFILI_ED. · "~:.'. FI CONTINUC)IJS MFIINTENFINCE FIGREEMENT IS RE(;!UIRED. IF FI MFIiN"fENFINCE FIEiREEMENT CS NOT KEPI" CLIRRENT YOU MFI¥ BE REC::IUIRED TO ENLARGE THE SOIL. FIBSORPTION SYS-T, TEM RND,.."OR YOU MAY BE SUBJECT TO PROSECUTION. "¥ I~.-IIC~ ( 2:'}:: ]:, Ii I'-.ItSF'E.~ C:]I"" I r'nr-l~; AIiL:E ~:i~,]:.,.ltj ][ t~.'.E.C lC:, ............... BFIC::I<FIL...LING OF FINY SYS]'EM WITHOUT FINFII. II'.,Iff.;PECTION AND APPRO',,,'AL BY THIS F:,E. PFIRTMEI'.,t"I'~ I.,41 L..L. BE SUB..TEGT TO PROSEC'U]" I ON. MINIMUM [:,ISTANC:E BETWEEN A WELL AN[) ANY ON-SI'TE; SEWFIGE [:,ISPC)SAL SYSTEM IS :[.00 FEE']" FOR Ft PRIVATE WELl_ OR 200 FEET FOR A PUBLIC; WELL. WEL. L LOGS ARE REQUIRE[:, AND MUS]" BE RETURNED TO THE [:,EPARTMEN]' HITHIN 2i:0 [:,RYS OF' 'THE WELL COMPLETION OTHER REQUIREMENTS MAY FIPPI_Y. SPEC;:iFtCFITIONS AND CONSTRUCTION DIfqGRAMS ARE AVAIL. ABLE 'TC) INSURE PROPER INS]"FI/_LA'T'ION. I C:ER'T'IF'Y THAT :1.: I FII"I FFIMILIAR WITH THE REQUiREZMENTS FOR ON-SITE SEWERS FIND WELLS AS SE"I" F'ORTH BY 'T'HE MUNICIPHLITY (DF ANCHORFIGE. 2: i HILL. iNSTFtLL THE SY.".::;TEM IN FICCORDFINCE WI"1"t.4 THE CO[;,ES. .::.. i I...IN[..Et~.::,IHN[. 1HHI ]HD~'"/uNc...:,IIE .:,EHER :,..r=,tEfl flH'r RE.: ...... [F:.E. ENL. HF..aEflENt RES 'f [:,ENCE :I:~REMO[:,ELED. /~q::l I~C::I[U[::,E MnF.:E THFIN_ ,1. BEDROOMS. i , lIE[, 8" ';;'":; ...... :, :,,, ' ¢ DH-CE ~'.-. ..... , ................................... 7 I F THE '95:. 0 UNWIN · SCHEBEN · KORY N TA CONSULTING ENGINEERS AND SURVEYORS I 103 E. 26TH AVE., ANCHORAGE (99503) August 31, 1977 (907) 2764245 Ms. Shirley Allen 1321 Wintergreen Anchorage, AK 99504 Re: Test Hole Log and Perculation Test Lot 9, Block 1 of Conifer Heights Subdv. Our Work Order No. 77842 Dear Ms. Allen: Attached herewith is the test hole boring log, perculation test results and our comments regarding soil conditions encountered on the subject lot. In accordance with your request, our investiga- tion was conducted on August 30 and 31, 1977. A single test hole was placed on the lot as indicated on the attached location sketch. Drilling was accomplished utilizing a mobile drill rig B-50 mounted on a track vehicle owned and operated by Denali Drilling. The purpose of the investigation was to provide soils data for establishing the feasibility of onsite disposal of sanitary wastes. The test hole was extended to a total depth of 16 feet below the existing ground surface. No ground water table was encountered in the test hole, in addition, the soils near the bottom of the hole were relatively dry. Soils were as indicated on the attached boring log. After completion of the drilling, the test hole was backfilled and hand tamped to approximately the 12 foot level and filled with water. Approximately 24 hours later, the test hole was refilled with water to approximately the 6 foot level and a perculation test conducted in accordance with the manual of septic tank practice of the U.S.P.H.S. Measured drop in the water level during the last 30 minutes of the test was 6.75 inches for a computed perculation rate of 4.4 minutes per inch. If you have any questions with regard to the above, please contact me. Very truly yours, Attachments EDK/clr GORDON D. UNWIN, P.E. LEO SCHEBEN, dR., P.E., L.S. EARL D. KORYNTA, R E. SHEET , OF~ SOILS lOG PROJECT CLIENT Shirley Allen W.O. 77842 Lot 9, Block 1 Conifer Heigbt~ Sub.TEST HOLE NO. ELEV. TOP OF HOLE DATE 8/30/77 Lot cleared & topsoil stripped. Dry, brown, fine/medium silty sand (SM) Dry, brown, fine/medium silty sand (SP/SM) Trace Gravel Damp brown, gravelly, sitly sand (SP/SM) Bottom of Hole No Ground Water 0 "4 5'*/9 _,c'o ~ / ?S. 7~ .-..y MUNICIPALITY Of ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 :- ~'~ '~:'~'~:'~343'4744 CERTIFICATE OF HEALTH AUT .HORITY APPROVAL FOR A SINGLE FAMILY DWELLING GENERAL INFORMATION Complete legal description Location (site address or directions) Property owner Mailing address Lending agency Mailing address Agent Address Day phone Day phone Day phone e Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: ing to the legality and status of system. If community well system, provide written confirmation from State ADE,C attest- xy,. 7,. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and Status of system. 72-025 (Rev, 1/91) Front MOA #21 Name of Firm ~¢~,JJ)~-l'z..~O~ ~"~4, i,'J~-'/'~*JL, Phone Address PO Engineer's signature ~ ~-~ STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewate.r disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Date DHHS SIGNATURE Approved for Disapproved. Conditional bedrooms. approval for bedrooms, with the following stipulations: Additional Comments '~he Mdnlcip~lity of A.~h&rage Department of Health and Human Services (DHHS) issues Health Authority 'Approval c~rtificates',b'ased only upon the representations given in paragraph 5 above by an ndependent professiopal engin,'.~'registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and t~eir I~nding institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's workJ 72-025 (Rev. 1/91) Back MOA 1t21 ~UN~C~P^LnY o~ mV~ON~ENT~ ~E~WC~ DtV~ON of Anchorage MA~ 0 4 1997~ Municipali~ DEPARTMENT Of HEALTH & HUMAN SERVICES R E C E IV E Environmental Services Division 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744 Health Authority Approval Checklist Legal Description: ~ ¢~. ~l, oc...~/; ~-O~/~'~/~- /L/~j. Parcel I.D.: A. WELL DATA Well type T~I,~T~ Log present (Y/N) Y Total depth Sanitary seal (WN) · If A, B, or C, attach ADEC letter, ADEC water system number Date completed Cased to Z.:~ Z../ Casing height (above ground) Wires properly protected (Y/N) FROM WELL LOG AT INSPECTION Date of test Static water level I-/3- 97 5.3 Well production 7 g.p,m. g.p.m. WATER SAMPLE RESULTS: Coliform O Nitrate '/~ /Vt ~//..,. Date of sample: //i~/'7 Collected by:. Other bacteria B. SEPTIC/HOLDING TANK DATA Date installed /0- Z.~-77 Tank size /,'7-..~40 Number of Compartments ~' Cleanouts (Y/N) . Foundation cleanout (Y/N) ~1~ Depression (Y/N) /~J High water alarm (Y/N) /k/ Date of Pumping /'-Z/-~7 Pumper //~o~O ~:)D?"c~Z?- C, ABSORPTION FIELD DATA Date installed /~-Z_.~-77 Length /'/'~'; Width '-~ I Gravel thickness below pipe Effective absorption area ~"~) ~ Monitoring Tube present (Y/N), Y Date of adequacy test f-.-/¢) -' ¢~7 Results (Pass/Fail) Fluid depth in absorption field before test (in.); ~,~;2 Immediately after Fluid depth Soil rating (g.p.d./fF or fF/bdrm) /fro ~' Z'System type ~"~ ~" / Total depth /~ / , Depression over field (Y/N) For _ //~'"--~ u~t.... .bedrooms gal. water added (in.): (ins) Minutes later: ~"/ /-~,. Absorption rate = ~,O43 g.p.d. Peroxide treatment. (past 12 months) (Y/N) /"/ If yes, give date 72-026 (Rev. 3/96)* Date installed ~~_~~ Size in gallons .M_.a~hole/Access (_Y/N!_ ~ "Pump off" level at* ~igh water alarm level at* *Datum ~ Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot ). 1 OO Absorption field on lot >/OO ~ Public sewer main Sewer/septic service line On adjacent lots On adjacent lots Public sewer manhole/cleanout Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: ! Foundation ~/~:) Property line ~, /0 Water main/service line ~' ~ / Surface water/drainage >/~' ' SEPARATION'DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line ~'/0 Building foundation ~/~) / Surface water Curtain drain /~/O~,/~C ~A/ ~-..~7" Absorption field Wells on adjacent lots ~/00 Water main/service line Driveway, parking/vehiCle storage area Wells on adjacent lots ~/~O ~ ! '>/O F. ENGINEER'S CERTIFICATION in Conformance with MOA H~ guidelines in effect on this date. Engineer's Name are HAA Fee $ ~) ~'/~'/~ Date of Payment '~ //'~/c~ 7,' ~ Receipt Number ~-~'"~ ~ Waiver Fee $ Date of Payment Receipt Number 72-026 (Rev. 3/96)* MEMORANDUM RECEIVED MAR 1 3 1997 DATE: March 12, 1997 Municipality of Anchorage Dept, Health & Human Services TO: Dan Roth, MOA- DHHS FROM: Mike Anderson, P.E. SUBJECT: Lot 9, Block 1, Conifer Heights Subdivision Certificate of Health Authority Approval We inspected the well head on Lot 9, Block 1, Conifer Heights Subdivision on Tuesday, March 11, 1997. A sanitary seal has been installed and the wiring is now in conduit. The Certificate of Health Authority Approval can now be issued. Please let me know if you have any questions or comments. February 28, 1997 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Attention: On Site Services Engineer Subject: Lot 9, Block 1, Conifer Heights Subdivision Certificate of Health Authority Approval Dear Reviewer: The owner of the subject property is currently refinancing her home and the bank is requiring a Certificate of Health Authority Approval. The attached package is submitted for your review. Please note the well does not currently have a sanitary seal or wiring encased in conduit. The owner, however, has assured me this will be completed by early next week and should not delay the processing of the certificate. We will verify the repairs have been made and notify you. The septic system on the lot was constructed in 1977 and is nearing the end of its useful life. A substantial buildup of sludge was noted in the system during our initial inspection which appeared to be clogging the distribution line. An initial test on the system indicated' a very high absorption rate. The water level during the test, however, rose above the invert of the distribution line. The sludge buildup was removed from the system and the absorption trench allowed to stabilize over a one month period. A second adequacy test was then performed. The water level in the trench was measured at 60" prior to the start of the second adequacy test. 'Water was introduced into the trench at a slow rate to assure the level did not rise above the distribution piping. At no time during the test did the water level rise above the invert of the distribution pipe. The septic system remained in service during the test. Lot 9, Block 1, Conifer Heights Subdivision February 28, '1997 Page Two A total of more than 600 gallons of water was pumped from the well directly in to the absorption trench. During the test period a minimum of 300 gallons was added to the system through household use. After 24 hours the water level did not return to its pre test level, but nearly 600 gallons had been absorbed by the system. The system continued in use after the test. The water level in the trench was measured at 60" during our next visit to the site which was approximately 2 days later. The owner of the property has been informed the system is nearing the end of its useful life and no guarantee as to how long the system will last has been made as a result of our test. Sincerely, Michael E. Anderson, CT&E Environmental Services Inc. Laboratory Division Laboratory Analysis Report CT&E Ref.# Client Name Project Name/# Client Sample ID Matrix Ordered By PWSID 970196001 Anderson Engineering Lot 9 Block 1 Conifer Hts. Outside Faucet Drinking Water Client PO# Printed Date/Time 01/16/97 16:16 Collected Date/Time 01/13/97 14:00 Received Date/Time 01/13/97 14:25 Technical Director: Stephen C. Ede Released Sample Remarks: Sample collected by: Gilbert Parameter ALlowabLe Prep Analysis Results PQL Units Method Limits Date Date Init Nitrate-N 0.100 U 0.100 mg/L SM18 4500-NO3F 10 max 01/15/97 JBL Total Coliform 0 col/lOOmL SM18 9222B 01/13/97 TAV 200 W. Potter Drive, Anchorage, AK 99518-1605 -- Tel: (907) 562-2343 Fax: (907) 561-5301 3180 Peger Road, Fairbanks, AK 99709-5471 -- Tel: (907) 474-8656 Fax: (907) 474-9685 ENVIRONMENTAL FACILITIES IN ALASKA, CALIFORNIA, FLORIDA, ILLINOIS, MARYLAND, MICHIGAN, MISSOURI, NEW JERSEY, OHIO, WEST VIRGINIA DATE RECEIVED INSPECTION APPOINTMENTS ~ _~__.~p TIME TIME TIME ' DATE DATE DATE INSPECTOR INSPECTOR 1 NSPECTOF~ MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH& ENVIRONMENTAL PROTECTION DEPT. ©F ( 825 L Street - Anchorage, Alaska 99501 ENV~RONMEi'~i,"-.L i ,.,z fL~CTION ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWE~I~I~IEEt~I'tVE~L~ DIRECTIONS: Complete all parts oil page 1. Incomplete requests will not be processed. Please allow ten {11~) davs for processing. 1. PROPERT~ OWNER ~.~ PHON MAILING A~DCR'ESS ~ ~ -- , v ....... PRO~ER'~Y P/ESIDE[~L~.(If diffe[e~t f~ror, n .abVv, ) /.~. PHONE 2. BUYEF~ ' PHONE MAILING ADDRESS 4. REALTOR/AGENT PHONE MAILING ADDRESS 5. LEGAL DESCRIPTIO I 6. T~PE OF RESIDENCE [~'~'~G L E FAMILY [] MULT, PLEFAM,LY NUMBER OF~BEDROOMS [] One [~'~'~our [] Two [] Five [] Three [] Six [] Other 7. WATER SUPPL~ [~3-~NDIVI DUAL* [] ;COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach log if available.) 8. SEWAGE DISP,~;)SAL SYSTEM ~INDIVI DUAL/ON-SITE~* [] PUBLIC UTI LITY YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. 6/79) THIS SIDE FOR OFFICIAL USE ONLY 1, TYPE OF RESIDENCE [] SINGLE FAMILY [] MULTIPLE FAMILY 2. WATER SUPPLY [] INDIVIDUAL [] COMMUNITY [] PUBLIC UTILITY Connection Verified 3. SEWAGE DISPOSAL SYSTEM [] IN DIVI DUAL/ON -SITE []PUBLIC UTILITY Connection Verified []Septic Tank or [] Holding Tank Size: I~.S-c5 If Tank is homemade give dimensions: TYPE OF TANK TOTAL ABSORPTION AREA 4, DISTANCES WELL TO: Absorption Area to nearest Lot Line NUMBER OFBEDROOMS [] ONE [] TWO [] THREE [] FIVE [] FOUR [] SIX PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED PERMIT NUMBER DATE INSTALLED INSTALLER SOl LS RATING MAN U FACTUR ER.~~[. MATERIAL Septic/Roldin§ Tank ~Absorption Area Sewer Line [] OTHER INearest Lot Line 5. COMMENTS DATE ~'~' APPROV ED FOR ~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany~icate) [] DISAPPROVED 72-010 (Rev. 6/79) 1980 Jame ~~ Allen/Shirley Allen Henderson 1321 Wintergreen Anchorage, Alaska 99504 Subject= Lot 9 Bloak 1 Conifer Heights Subdivision Approval for your individual sewer and water faoili~ies can not be granted until the following items have been completed: (1) A well log submitted to this department for our review. (2) The water analysis report be delivered to this office from Chem Lab, 5633 B Street, for our review. If there are any questions, please call this office at 264-4720. Robert C. Pratt, R.S. Associate Specialist RCP/lJw Security National Bank Mortgage Loan Department 2525 C Street - Suite 250 99503