CONIFER HEIGHTS BLK 3 LT 15
0\6-C ° 3 - 0 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page of ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP221329 PID Number: 015-093-08 Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade Name MIRIAM & JOHN NOLTE ABSORPTION FIELD ❑ Deep Trench ® Wide Trench ❑ Bed ❑ Mound Site Address 9400 PONDEROSA DRIVE, ANCHORAGE ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 0.6 GPD/SF 6 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3 Ft. Gravel depth beneath pipe 3 Ft. Subdivision Block Lot CONIFER HEIGHTS 3 15 Fill added above original grade VARIES 0.41-0.66 Ft. Gravel length 116 Ft. Township Range section Gravel width 5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 1000 FF 2 10 Ft. Well 100'+ 100'+ 25'+ TANK ® Septic ❑ S.T.E.P. [:]Holding ❑ Other Manufacturer GREER Capacity 1500 Gal. Surface Water 100'+ 100'+ Material HDPE Number of compartments 2 Lot Line 5'+ 10'+ NA Foundation 10'+ 10'+ ILIFT STATION Manufacturer Capacity Gal. Remarks SEPTIC TANK &FIELDS INSULATED. OLD SEPTIC SYSTEMS DECOMMISSIONED. Alarm location Electrical installed by Installer NORTHERN EXCAVATION Tankto PIPE MATERIAL House to tank 3034 drainfield 3034 Drainfield 3034 co/MT 3034 Inspector FWC BENCH MARK (Assumed elevation) 100 ft Inspdection Is' 9/21/2022 2Id 11/14/22 Location and description 3'd 11/15/22 4" 11/15/22 TOP OF MANHOLE ON -SITE WATER AND WASTEWATER SECTION APPROVAL CIF Conditional Approval: Date ,di •''"''•.t$ •• •••• ••••••••••�' Septic System Curtis Huffman v� Approved - �'c�G' •. <�`L`�.m'� Date (2 / L z 3 CE 128991(AJ .• VIP, • ..1/20/23... • �,�C� ,, �k�, pROFES510 L�- Note: this approval does not include well permit requirements. kRCv VZ)/UL/ 16) P I D: 015-093-08 PERMIT: OSP221329 LLED TO OTTOMKOFILNEW TANK INGS AELEVATIONS. Q v/ BM: TOP MH D EXISTING SYSTEMS DECOMMISSIONED INSTALLED TRENCHES PARALLEL TO SLOPES, 10' APART & BEST FIT POSSIBLE 1� INSTALLED 2 58'L X 5'W X VED —6' OG FIELDS L W/ SPUTTER & DCO BM: TOP OF MH A—C=23,8' /// MH B—C=37,3' DFCO / CO CO MT CO MT ` 99.95 DOD 98.20 FINAL GRADE 98.27 A—D=27,9' 97.79 ORIGINAL GRADE TH22-1 B—D=40,5' 96.04 rFILTER FABRIC RELATIVE ELEV. INSUL i do INSULATION ORG/OL A—E=30,0' 2.0' 95.46 95.29 s'V R 4.79 94.79 B—E=42,1' SEWER ROCK 3' A—F=31,9' 1 HOPE TANK500 N 91.78 91 GM/mI B—F=43,7' 97•77 CO MT FINAL GRADE CO MT 97.91 A—G=47,9' DSTLLLED 87.25 INA ORIGINAL GRADE WTR 011, TO BOTTOM OF FILTER FABRIC 10/11/22 B—G=41,0 SEPTIC TANK ELEV. k INSULATION 8625 A—H=50,0' 4.25 94.25 14' SEWER ROCK 3' 83.25 BOH B—H=43,0' A—M=51,5' SEPTIC SECTION 8125 9125- A—I=41,4' B—M=61,9' SCALES NTS B—I=53,9' A—N=53,1' GRND. WTR 011' OR 86.25 ELEV A—J=42,5' B—N=63,3' 10/11/22 = 5' SEPARATION B—J=54,8 ' SUPPORT SERVICES: am B—K-59,5 CONIFER HEIGHTS BLK 3 LT 15 OF A—L=65,8 PREPARED FOR:��� B—L=60,9' MIRIAM & JOHN NOLTE 9400 PONDEROSA DR * GJ TH ANCHORAGE, AK 99507 FIRST WATER CONSULTING 13030 Sues WayDATE: 1/20/2023 * is Huffman 4; SURVEY: JLS CE 128991 Anchorage, Alaska 99516 DRAWN: FWCS �1/20/2023cs (907)350-9566 SCALE: 1" = 30'OssloNAv FirstWaterAK©gmoil.com A23-13U1L1 UN: g� CONIFER HEIGHTS LOT 15 BLOCK 3 PLAT 71-190 SURVEY CERTIFICATE: I, John L. Schuller, Have conducted a physical survey of this property as shown on this drawing and that the improvements situated hereon are within the property lines and no enchroachments exist other than noted. Under no circumstance shout( any information on this drawing be used for construction of fences, structures, improvements, or for establishing boundary lines. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. WORK ORDER NUMBER: DAM SCALE: F— AIL NOV 29, 2022 1"=40' schuller@ak.net 22-097-2 DRAM BY: (NECKED BY GRID NUMBER: g(qK Ate; JLS SW2440 220371 vs — r1N11 1 L 111W1N r1rL OO = FND 518" REBAR 01 4 9TH I �/C 2, j�j •.J0HN L. SCHULLER.-* o i s• � N LS-10408 fessiono\ 0 - o I � 0 CV 11 ry to O O 00 11 ' J 25' 1 O Q U LL1 Z' O Q. r r 1 25' 1831 Talkeetna Street Anchorage, Alaska 99508 (907) 227-1455 office (907) 274-4992 fax MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP221329 Work Type: Septic Upgrade Tax Code Number: 01509308000 Site Legal Address: CONIFER HEIGHTS BLK 3 LT 15 G:2440 Site Mailing Address: 9400 PONDEROSA DR, Anchorage Owner: NOLTE JOHN M & MIRIAM R Design Engineer: FIRST WATER CONSULTING This permit is for the construction of: Effective Date: Expiration Date Lot Size in Sq Ft Total Bedrooms: '»cnt off. ti _ fir. U n De partin ent 9/13/2022 9/13/2023 38895 Q Disposal Field 2 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: • CO #1 Added a field to the permit. The system size is changed to 4 bedrooms. -bareived$y: 155 a e -A -f o �Gt�� Date: Issued By:/ll% Date: ............. . . llzzZ 4 X Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 015-093-08 Property owner(s) JOHN & MIRIAM NOLTE Day phone _ Mailing address 9400 PONDEROSA DRIVE, ANCHORAGE, AK 99507 Site address 9400 PONDEROSA DRIVE, ANCHORAGE, AK 99507 Legal description (Sub'd., Block & Lot) CONIFER HEIGHTS 133, L15 Legal description (Township, Range & Section) Lot Size 38,895 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) El (w/wo ADU) Septic Tank 0 Upgrade El Duplex (D) El Holding Tank El Renewal El Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. nature of property owner or authorized agent) Permit/Rush Fees: 225 Date of Payment:�d/ Z Receipt Number: .51531 W 3 Permit No. 1 3 2 9 Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc 0 Co -'e7,_1 Flrs[ Water ®- CONSULTING �V{ATEftIV-tP Si:Vlki £A ,,^ "i- SUPPORT PLANNING 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com October 31, 2022 Municipalities of Anchorage On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC SYSTEM UPGRADE PERMIT — OSP221329 LEGAL: CONIFER HEIGHTS BLOCK 3, LOT 15 It was determined at the time of septic tank installation that the existing septic field was encroaching groundwater and the property owner requested we obtain a permit to upgrade the failed septic system of the above referenced lot. We propose to decommission the existing absorption field and install two shallow trenches to serve the existing 4 -bedroom residence. Please amend the permit to 4 bedrooms. The other or `A51h bedroom" is a den or office without proper ingress/egress windows,... The design is based on available data and the recent test hole conducted in the fall of 2022 with October groundwater readings per the attached. The slopes are moderate at 3-8% at the proposed upgrade location and flatter slopes below. The lot and area are served by private water. The design will not impact any of the neighboring properties. The owner and excavator, Northern Excavation would like to proceed as soon as possible given the weather and change of the season. Please contact us if you have any questions. Sincerely, i Curtis Huffman, P.E. First w61, L. cata;1LIING, SEnvicrs � SRPPR 9IE PLANNING cc n� DESIGN CALCS: 4 BDRM X 150 GPD = 600 GPD 600 GPD/0,6 GPD/SF. = 1000 SF SAS 1000 SF / 5'W x .58 RF (3' ED) = 116 FT. TRENCH NO SLOPES >25% WITHIN 50' USE 2 TRENCHES - 58' (L) X 5' (W) X 3'(ED) TOTAL DEPTH FROM EXISTING GRADE, -6' OF PROPOSED FIELD. NOTES: STAKE PROPERTY LINE & WELL RADII PRIOR TO CONSTRUCTI❑N STAKE ANY REQUIRED SEPARATIONS TO SEPTIC SYSTEM PRIOR TO CONST. CONIFER HEIGHTS BLK 3, LT 15 PREPARED FOR: MIRIAM & JOHN NOLTE 9400 PONDEROSA DR ANCHORAGE, AK 99507 FIRST WATER CONSULTING 13030__ SUES WAY ANCHORAGE, AK 99516 907-350-9566 FirstWaterAK@gmail.com INSTALL SEP -NC FIELDS PARALLEL TO SLOPES NO PRIVATE WELLS WITHIN 100' OF PROPOSED SEPTIC SYSTEM SUPPORTISERVICES: ®®®® ®�4OFA4� F.W., I c 5 d 'OF is",) C �2->* 9 TIi DATE: 10/31/2022 _is Huffman SURVEY: JLS - - CE 128991 DRAWN: FWCS __.__ X SCALE: 1 = 60' I /31/22 �/ PAGE: 1 OF 2 \ FEssto DESIGN DETAILS: DECOMMISSION EXISTING FILED & INSTALL 2 NEW 58'L X 5'W X 3'ED W/ SPLITTER & DCO . MAINTAIN 10'+ FROM FOUNDATION, 100' TO WELL ON PROPERTY, 100'+ TO OTHER PRIVATE WELLS, 100' TO SURFACE WATER, 5' TO FIELD & DECK SUPPORTS OR PILING TO BOH FOR TANK, WITH 4' OF COVER OR INSULATION. INSTALL PER AMC 15.65, 15.55, & MASS ... TANK BEDDING, SEPARATIONS, MATERIALS,.. SCAT LOT 17 STAKE PROPERTY LINE RADII,WELL REQUIRED SEPARATIONS TO SEPTIC SYSTEM ' PRIOR TO CONST. ti MT O o nj�IAC SHED ON / SKIDS LOT 18ECOMMI SION STINGSFIELDCO DECK PILLI / DRIVEN V� Vco1O \ °, !� A47- CO TCO M DFCO / s O ® -5' LOT 14 MT t/1F �Y INSTALL SEPTIC FIELDS PARALLEL TO SLOPES CONIFER HEIGHTS BLK 3 LT 15 PREPARED FOR: MIRIAM & JOHN NOLTE 9400 PONDEROSA DR ANCHORAGE, AK 99507 FIRST WATER CONSULTING 13030 SUES _WAY- -------------. ANCHORAGE, AK 99516 907-350-9566 FirstWaterAK@gmoil.com / STAKE 100' WELL RADII PRIOR TO CONST. , 2�0 G ISS �4 �9 LOT 15 TH22-1 m BLK 3 DECOMMISSION EXISTING SEPTIC FIELD & INSTALL 2 NEW 58'L X 5'W X SED -6' OG FIELDS W/ SPLITTER & DCO NO PRIVATE WELLS WHIN 100' OF PROPOSED SEPTIC SYSTEM / SUPPORTISERVICES: ®®®® OF AL® _ A0 C 5 �* �TH k DATE: 10/31/20220 Huffman ,� SURVEY: JLS , CE 128991 DRAWN: FWCS SCALE: 1" = 30' ,\ 10/31/22.�',�OI PAGE: 2 OF 2ssioN�' i °F*4 F fpol, W are r %g�P.TM� S U L T I N G• .. ....... WATEnlBlA7Fn — suvronTF.zPtar:rnnc - 13030 Sues Way - Anchorage, Alaska 99516 Curtis Huffman Tel. 907-350-9566 firstwaterAK@2mail.com �� k-61', ._ CE 128991 4���� 10/12/22 SOILS LOG -PERCOLATION TEST �PROFESSIONP`���' LEGAL DESCRIPTION: CONIFER HTS. B3. L15 DEPTH FEET OG SOILS Net Drop _ _ = ORG/OL 6" 1 13/16" 2 =_ 3 30 min 4 1 13/16" 5 6 7 GM/ml 8 9 10 11 12 13 14 BOH 15 16 17 18 19 20 PERFORMED FOR: JOHN & MIRIAM NOLTE TESTHOLE # 22-1 DATE PERFORMED: 9/22/22 GROUNDWATER ENCOUNTERED: YES IF YES, AT WHAT DEPTH: 10'-11' SEEPS / DAMP DEPTH TO WATER AT MONITORING: 11' DATE: 10/04/22 & 10/11/22 SEE SITE PLAN FOR SLOPE & LOCATION COMMENTS: SAS MAINTAIN -6' MAX GRADE. VERIFY GROUNDWATER MT AT TIME OF CONSTRUCTION Reading Date Gross Net Time Time Depth to Water Net Drop 10/4/22 30 min 6" 1 13/16" 30 min 6" 1 14/16" 30 min 6" 1 13/16" PERCOLATION RATE 17 (MIN/ INCH) TEST RUN BEWTWEEN 3.5 & 4.5 FT PERC HOLE DIAMETER 6" PRE-SOAKED PRIOR TO TEST & ALL READINGS TO THE 1/16TH. PERFORMED BY: FWCS / FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 10/12/22 On-site Water and Wastewater REVI FOR AE COIV PUAC LOT 16 21329, Tim Ec Lrd, 09/13/22 o Lo / o app pp / o C5 / 00 25' 25 LOT 17 / PAVED WELL I / ^^ 4l8 CO UNG SXIST SS II ! HO ! z D� h �2.5�o�U 'a o O� O SEPTIC VENT (typ) LOT 15 LOT 18 \� j BLK 3 to J/ O 00 CN N50.17,00,$W 210, p0, � t LOT 14 ANCHORAGE RECORDING DISTRICT, ALASKA J AS-BUILT OF: ®=FND 12" IRON PIPE CONIFER HEIGHTS U = FND 518" REBAR LOT 15 BLOCK 3 PLAT 71-190 �� SURVEY CERTIFICATE: 1, John L. Schuller, Have conducted a 0 F AO"A ,lk>� SUR physical survey of this property as shown on this drawing and that the �� w4 oT ` L ° s� I� improvements situated hereon are within the property lines and no �'� Ry�'' g V - ' 'P, C� enchroachments exist other than noted. Under no circumstance shoal * 4 9I'Hf�4� any information on this drawing be used for construction of fences,V structures, improvements, or for establishing boundary lines. ... Q n EXCLUSION NOTES; It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which s ' 3t1HN L. SCHULLER, do not appear on the recorded subdivision plat.el`. LS-10408 WORK ORDER NUMBER: DATE SCALE: E-NAIL' �� 1831 Talkeetna Street 1.SEPT a -:� a Anchorage, Alaska 99508 22-097 DRAM By.- CHEDkED2Bv exam HUMBEsOt scnwlB��A�t ����rofessiona\ \'. (907) 227-1455 office JLS SW2440 220324 (907) 274-4992 fax MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL DESCRIPTION ~ DISTANCE TO: ~ M~nufacture~~ Mater~ m Inside len~ ~idth - kiquid de~th kiq. ca~itg in ~OO ~ IF HOMEMADE: .... Well Dwelling PERMIT NO. ~ DISTANCE TO: Z ~ ~ ~ Manufacturer Material Liquid capacity in gallons DISTANCE TO: Well Foundation~ ~ I~{ ~ lengthways Trench~h~ Distanc~lines ~Q~ Too of tHe to finish ~rado ~. ~ater,alb~neatht, lo ~ ~ Totala~e~B~ sorpt,onaroa ~ ~ Tgpo of crib Crib diameter GriB depth Total offecti~o absorption area m Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth Driller Distance to lot line PERMIT NO. ~ Building foundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: OTHER PIPE MATERIALS SOIL TEST RATING REMARKS APPROVED~ ~ ~ DATE LEGAL 72-013 (Re~, U78) Permit ~ Applic~t: ~~ ~ ~~., ~, Mailing Address:~ ~ ~ Location: Phone Nu~er: Legal Description: ~£~ ~ ~ ~ Lot Size: Type of Soil ~sorption System Is: Trench: ,/ Drainfield: Seepage Bed: Holding Tank: Maxim~ N~ber of Bedrooms: ~ Soil Rating(sq.ft/br) MUNICIPALITY OF ANCHORAGE partment ~ Health and Environmental ~rotection 825 L Street, Anchorage, ~K. 99501 * * * HANDWRITTEN PERMIT * * * W~R ON-SITE SEWER PERMIT ~~ The Required Size of the Soil Absorption System Is: DEPTH /o~ LENGTH /~D.. GRAVEL DEPTH 7 WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(~G) TANK SIZE = ~_~ GALLONS * * Permit applicant has the responsibility to inform this departmen~ during 'the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER ]~1~ 1 9 8 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more that ~bed~ms. Signe~ :~~' ~ ~/~Z~N' Applicant ~ Issued by: Date: /~ --~ ' ~ SWP/024 (1/81) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage. Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LOCATION ~W ,F~, g~~~ ~/m NO.O~BEDROOMS ~r ~ Manufacturor ~~ Mate~~ ~o. of c~partments Liq~x~i~ i~g~l~ns IF HOME.DE: Inside length Width Liquid depth ~ DISTANC~TO: Well Dwelling PERMIT NO. Z ~ ~ ~ Manufacturer Material Liquid capacity in gallons ~ Well Found~, Nearesl~ne PERMIT NO. ~ DISTANCE TO: /~ ~of~e~ / Trenc~t~ Distance between lines ~ ~o. ofl,nes ~ ken~t~h~/ Total -- ~ inches ~ ~ ~ Top of tile to f~s~ grade = - ~~ til~ ~1 Total eff~ ~rption area konoth ~idth Do~th . ~ ~ Tg~e of crib Crib diameter Crib dopth Total effective absorption area m Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth Driller Distance to lot line PERMIT NO. Building foundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: OTHER REMARKS / '""?"" '" ' ~,,'~....-%. · ~,, ..... ....~ ...... ::0~~ kl~Y~ ) 113 (Rev. 0 o 0 0 o ~ 0 ~ ' 0 0 0 0 0 0 0 0 0 0 0 ,-.] ~] ,-] ,-] ,..] ~ ~ ,..] ~ ~] ,.-] ~ PERMIT NO. MLINICIPALIT¥ OF AHCHORAOE DEPARTMENT 0~ HEALTH AND ENVIRONMENTAL PROTECTION WELL Arid Or~--SITE SEWER PERMIT ( ?803?6 > APPLICANT LOCATION LEGAL OREO PETRO PONDEROSA DRIVE L15 B~ CONIFER HEIGHTS 48~8 BRYN MAWR #~ LOT SIZE ~-6940 42000 SQUARE FEET TYPE OF SOIL ABSORBTION SYSTEM IS' T~ENOH MAXIMUM NUMBER OF BEDROOMS SOIL RATING (SQ FT?BR>= 155 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS' C~E PT~H= i2 LE~IGTH= 34 GRAVEL DEPTH= ? THE LENGTH DIMENSION IS THE LENGTH (IN FEET> OF THE TRENCH OR DRRINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE E~CRVRTION (IN FEET>. THERE IS NO SET WIDTH FOR TRENCHES. THE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET>. REQUIRE~ SEPTIC TANK SIZE= 1000 GALLONS PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. TWO ( 2 ) INSPECT IONS ARE REQU I RED BRCKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN R WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR R PRIVATE WELb OR 150 TO 200 FEET FROM R PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. WELL LOGS RRE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN ~0 DRYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. PERM I T E~P I RES DECEMBER I CERTIFY THAT l: I RM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE S~STEM IN ACCORDANCE WITH THE CODES. ~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE ISR~ODELED TO INCLUDE MORE THAN 3 BEDROOMS. ISSUED V3:2 P.~UL G. HkNSE]~ P.E. :';Rk BOX 395-V ~\~;OkTORXG~:, ,kL-~SKA 99507 SRA Box 72H Anchorage, Alaska 99507 April 11, 19~8 Dear 5~. Hill: in accordance with your request, I j~e completed soils analyses~for on-site sewage disposal on Lots 5~nd 16; Block 3; Conifer Heights Subdivision, Anchorage. Drilling, consisting of three test holes, was performed on ~.~rch 28, 1978 by Denali Drilling, Inc. of Anchorage em- oloying a B-50 ~obile drill; logging and percolation testing were per- ~ormed by myself in accordance ~th the Unified Soil Classification ~ystem, the Soil Triangle, and 'the "~anual of Septic-Tank Practice". All three test holes were saturated at least 24 hm~s prior to the test. ~ae attached sheets detail the results. As is typical with soils in the 0'!:~lley-Hillside area, the encountered soils consisted generally of glacial drift composed of a mixture of silt, sand, and gravel. The silt compone~as a large influence on the per- colation rat~, measured to be 135,(155~and 200 sq ft/be~room. ~o 'test holes (TH 1&3) suffered some s~ghing during percolation, so two tests were repeated, with w~ter levels determined by means of a 1" perforated plastic pipe installed immediately after drilling. The three lots are amply covered v~th large spruce and birch trees, in- dicative of good drainage; however, the drainfield trench for Lot 5 should be located slightly southwest of TH 1, and about 5 feet higher in elevation in order to ~void potential seepage from a nearby low area that has no outlet. During breakup, water could collect in this low area and be detrimental. In my opinion~ the three lots appear s~tisfactory for on-site sewage disposal, in terms of topography, drainage, and soi~ percolation. ! ~o~-- . . / .._--~.~.- : / , - / × / ./ '~ .... ~qEATER ANCHORAGE AREA BORO"~H .-~,.~' ~z[./ ,~ Depa,'tment of Environmental Quality Anchorage, Alaska 99503 · , ~,,' S~II_S LOG - PEROLATION TEST Th~sformrepo~s: Sodslog .,~OU~ ,O~l~L~ - Percolation test _ . ,_. _, ~t~dT~ s-~° ~o~,~.- · ~epth ~ '~ ~ ~ d ~ ~ ~/ ,,,j 6- 7- 8 12 -' ~4AcP ~ uue-C d' Ic~--lg,~ 16' Was groundwater encountered? k~O ~1,~, E:~--~~s, at what depth Reading Date Gross Time Net Time Depth to Water Net Drop Percolation rate .~'~ z'/'~,~/j/2;~ Proposed i.~alla'tion: geepage Pit __ Depth of Inlet .. '. . , _ ._ Depth to bottqm~ pi~tr~~~C~ ~ , Performed By: ~...¢ ~~ .' Ce~ified BY: ~'~ 4'~48TE~, .~(. Cat's: _ ¢/.?¢,P .. MUNICIPALITY OF ANCHORAGE : '~" DEPARTME~IT OF HEALTH & HUMAN:SERVICES Division of Environmental Se .ryices -..-,. ...... (~n-Site Services Section : - P.O. Box 196650 -Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELI~I~G Parcel I.D.. #' ~ ~ _Z_~_ /~h h~' ~'~,~ '": NAA # 1. :: GENERAL INFORMATION ~;.' ~...,.~,. ,~,::~,' .~.,~:COmplete.~egal description ~o~ /~ ~ foc~"~' ~o~ Location (site address or directions) Property owner Mailing address Lending agency Mailing address Day phone ~ c~ oro~ Day phone .... ' II II ' ' :?t-Z~t~:~ Unless othe~ise requested, HAA 'will be held for .NUMBER OF BEDROOMS: ' :" NOTE: If commumty well system, prowde wn~en confirmation from State ADEC attest- '~ ...... '~.'-? tng to the legahty and status of system. · ,,," . ~-l;}t,t ,/, . ~.;~,~. ." , . . _?..~.~,~.,~"' - 4. -"TYPE oF WASTEWATER DISPOSAL: > ,~',, ~.', Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality~ and status of system. 72-025 (Rev. 1/91) Front MOA #21 Legal Description: Municipality 'of Anchorage ~ ICIP. DEPARTMENT OF'HEALTH'& H_U. MAN SERV~ ~,~o~,~-.rt/ ANCHo~ Environmental Services uivJsJon .... ~AL SERVI 825"L" Street. Room 502 · Anchorage, Alaska 99501e Health Authority Approval Checklist E CE i V E D A. WELL DATA Well type /~ r;t ~' c~ b e_ If A, B, or C, attach ADEC letter. ADEC water system number Log present (Y/N) Y' Date completed Total depth ~ $-O' Cased to ~ ~ ¥ ' Casing height (above ground) ~o t, Sanitary seal (Y/N)T' Wires properly protected (Y/N) FROM WELL LOG AT INSPECTION Date of test Static water level Well production 15' g.p.m, fi, O e g.p.m. WATER SAMPLE RESULTS: Coliform 0 cot / too ~/ Nitrate 3, / P- Q,p/.Z Other bacteria None Dateofsample: 3/Z7 /76' Collectedby: ~'[ah/,,fl Teclo~itca/ .;ervteq./ B. SEPTIC/HOLDING TANK DATA ~ {~17~ tooa~ot Date installed Ia / ~ ! & J Tank size Co6,y ~ ~ Number of Compartments I Cleanouts (Y/N) Foundation cleanout (Y/N) N Depression (Y/N) N High water alarm (Y/N) N, A, Date of Pumping ~ / ~ b / 9 ~f Pumper C. ABSORPTION FIELD DATA Dateinstalled lO / & / S j; Soil rating (g.p.d./fl2orfl2fodrm) I5'5'~,,,,Systemtype Length t~' ~g'~q" Width 3 ' Gravel thickness below pipe 7' Total depth t ~ Effective absorption area I o/0 o' Monitoring Tube present(Y/N). Y' ~Depression over field (Y/N) N 8~z Date of adequacy test 3 { ~ 7/P 6' Results pass/Fail) p~t.<.r For .C bedrooms Fluid dep~ in absorption field before test (in.); ~ $'" (.~e/oo., m,,. or"/, o,.0 z ~,¢/./~ n IrnmediatelyafterTeagal. wateradded (in.): {3'" Fluiddepth ~D ~ .(ins.) Minutes later: e~ n;,,,~AV Absorption rate = '~ .7S"0 g.p.d. Peroxide treatment (past 12 months) (Y/N) None tmno~,.,o ffyes, give date /x/, A. 04×0~×96 0~:0G CT&E ESI AMCHORAGE ~ 907S4~1S~ ~0.841 ~0~ CT&E Environmental Services Inc. Laboratory Division r____-_-__-_~_-._- .... : - -- -----:----- ....... ~ Laboratory Analysis Report CT&E Ref.# Client Sample ID Matrix 96 [064,8571 LIS B3 CONIFER HTS} 1064-01 Drinking Water Sample Remarks: Collected Date 03/27/96 Technical Director Parameter ResuLts aC PQL Units Method A:towable Prep AnaLysis Init QuaL Limits Date Date Nitrate-N 3,12 0.2 ~ng/L EPA 353,Z 03/28/96 E~4B 200 W. Potter Drive. Anchorage, AK 99518-1605 -- Tek (907) 562-2343 Fax; [907) 561-5301 3180 Pager Road, Fairbanks, AK 99709-5471 -- Tel: (907) 474-8656 Fax: (907) 474-968§ ENVIRONMEr~TAL FACILITIES IN ALASKA, CALiFORNiA, FLORIDA. ILLINOIS, MARYLAND, MICHIGAN, MISSOURI, NEW JERSEY, 0HID, W{~ST VIRGINIA CIVIL & ENVIRONMENTAL ENGINEERING · ENERGY CONSERVATION & ANALYSIS THEODORE F. MOORE, P.E. 14530 ECHO ST. PH: (907) 345-1355 ANCHORAGE, ALASKA 99516 May 20, 1996 Dan Roth M.O.A. DHHS P.O. Box 19-6650 Anchorage, Ak, 99519 Dear Mr. Roth: RECEIVED MAY 2.0 1996 Municipality o! Anchorage Dept. Health & Human Se~/ice8 This is to advise you that the cleanout/monitor tube in the upgrade trench segment serving the residence on Lot 15, Block 3, Conifer Heights S/D has now been restored to its original condition, per your request. Please proceed with issuance of the HAA certificate. Thank you Sincerely, Ted Moore, P.E. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) Lot 15; Block 3; Conifer Heights June 5, 1986 Location (address or directions) (b) Applicant Name Coldwell Banker Telephone: Home Business 561-2488 Applicant Address 4105 Tudor Center Drive, Anchorage, Alaska 99508 (c) Applicant is (check one): Lending Institution [] · Owner/builder [~2~(', Buyer [] ' Other [] (explain); (d) Lending Institution Alaska State Bank Telephone Address ATTENTION: Julie North/Anchoraqe, Alaska (e) Real Estate Company and Agent Coldwell Banker/Area Realtors Relocation Address ATTENTION: Lois Hodqes/4105 Tudor Center Driver Anchoraqe~ Telephone 561-2488 (f) I~tdhe HAA to the following address: Co. 99508 S & S En~ineerin~ SR~ 196X Eagle River, Alaska 99577 Lo ~ Hodges ordered by TYPE OF RESIDENCE Single-Family ~ Multi-Family [] Number o(Bedrooms 5 Other WATER SUPPLY Individual Well,I;[ Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite [] Public [] Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 (11/84) ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA ,..J INFORMATION A.s certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein, i further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Telephone ~ ~'//'~'- ~-~ ~ ~ Name of Firm -,~GtNEER1NG ,~v Address Date F~I~LF DIVCD ~..oo~ JUN I 0 t985 Approved for ,,_~z~ bedrooms by Date Approved _ ]x~,~ Disapproved Conditional Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 {11/84) WELL DATA MUNICIPALITY OF ANCHORAGE (MO~; HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST- FEBRUARY 1984 MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION JUN 1 0 Legal Description: ~ ~'~-'~ Well Classification ~ '~', If A, B, C, D.E.C. Approved (Y/N) Well Log Present (~/N) Date Completed ~ -- I ~--r7~ Yield i ! Total Depth ~'¢~ Cased to , LIf'c) + Depth of Grouting Static Water Level '2'-~1 ¢) Pump Set At Casing Height Above Ground Electrical Wiring in Conduit~)N).- Separation Distances from Well: To Septic/l:[c~eq4~ Tank on Lot Sanitary Seal on Casing ~N) Depression Around Wellhead (Y~) [ ¢:~ ; On Adjoining Lots To Nearest Edge of Absorption Field~.~n~ Lot ~ c:,'''~ I ; On Adjoining Lots To Nearest Public Sewer Line · J/~ To Nearest Public Sewer /4' Cleanout/Manhole ~/J~ To Nearest Sewer Service Line on Lot Water Sample Collected by '~ ~ ~ '~,t~~E:P,.a~& ; Date (O ' ~ Water Sample Test Results ~. ~; ~ Co m ments SEPTIC/I-J~ TANK DATA Date Installed ~ Size ~.~ .. I 1~-1~5 No. of Compartments Standpipes {~) Air-tight Caps(~)'N) Depression over Tank (Y~:~ Pumping/Maintenance Contract on File (Y/N) /~, Holding Tank High-Water Alarm (Y/N) I'~ H Separation Distances from Septic/+4etdif~ Tank: t To Water-Supply Well ~.~)c~ Foundation Cleanout (Y~j~ /Date Last Pumped ~'~.-~7 ~' ; for / Temporary Holding Tank Permit (Y/N) ~J~ To Building Foundation ~ ' To Property Line ~ 6)14' ' -~ To Disposal Field ~' ~ To Water Main/Service Line . ~.~ ~+ To Stream, Pond, Lake, or Major Drainage Course /~/ik~ Comments Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata ~'~-~ ~:~'~' Type of System Design Width of Field Square Feet of Absorption Area Depression over Field (Y/~ Results of Last Adequacy Test ~ Separation Distance from Absorption Field: Depth of Field Gravel Bed Thickness Standpipes Presen (~N) Date of Last Adequacy Test To Water-Supply Well To Building Foundation Lot To Water Main/Service Line To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area To Property Line ~.~..~ c ~ To Existing or Abandoned System on ; On Adjoining Lots ~ '~' To Cutb/ank (if present) Comments D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Dimensions Manhole/Access (Y/N) ,~/j] "PumpOff"Levelat /~ Vent (Y/N) / Pumping Cycles during Adequacy Test. Meets MOA Electrical Codes (Y/N) Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certi~' ~ I~ll~~~fied, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Date ~JN I 0 !~)-~ MOA No, (¢~'-..-d2D.~ Sig ne.,~ _~ Co m ir~Ll: .ece .t Date of Payment Amount: $ Page 2 of 2 72-026 (11/84) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date ~',~-"7 GENERAL INFORMATION (a) (b) (c) Legal Description (include lot, block, subdivision, section, township, range) Location (address or directions) Applicant Name 'l~::>,,~,,aw...¢.....,~.. Telephone: Home Business ~"4,=, Applicant Address Applicant is (check one): Lending InstitutionJ~; Owner/builder []; Buyer []; Other [] (explain); (d) Lending Institution Telephone Address (e) (f) Real Estate Company and Agent ~'¢~-"~' ¢(~/ Address Telephone ~e HAA to the following address: TYPE OF RESIDENCE Single-Family ~ Multi-Family [] Number of Bedrooms Other WATER SUPPLY Individual Well [~ Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4, SEWAGE DISPOSAL Onsite~ Public [] Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 72-025 (11/84) Page 1 of 2 ~NGINEERING FIRM PROVIDING ,SPECTIONS, TESTS, FILE SEARCH, DAI.. ,~ND INFORMATI As certified b my seal affixed hereto and as of the val dation date shown be ow ver fy that my nvest gation of th s Health Y ' Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Telephone Name of Firm Address Date Approved for ¢/~"~ be te Approved ~,.,,/ Conditional Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer regimered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certmn federal and state requirements. Employees of DHEP do not conduct inspections or an~tyze data before a certificate is issued. The Municipality o~ Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (~ ~,84) MUNICIPALITY OF ANCHORAGE (MOA/ HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST- FEBRUARY 1984 264-4720 MUNICIPALITY OF ANCHI~pulkQG. DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION Description: Legal ~ WELL DATA Well Classification ~, F::. If A, B, C, D.E.C. Approved (Y/N) Well Log Present (~;~N) . Date Completed ~',.- ~, t, ~ ~ ~ Yield , ~ ~'p~ 4."'" Total Depth CZ~-"C>' Cased to ~::~t.[. Depth of Grouting Static Water Level '~.qc,' Pump Set At Casing Height Above Ground Electrical Wiring in Conduit ~/N) Sanitary Seal on Casingd~N) Depression Around Wellhead (Y_~ Separation Distances from Well: To Septic/Hel~img Tank on Lot ~ ~" ; On Adjoining Lots To Nearest Edge of Absorption Field qn Lot t¢::;'~'/' ; On Adjoining Lots To Nearest Public Sewer Line ~ To Nearest Public Sewer Cleanout/Manhole "'3~ To Nearest Sewer Service Line on Water Sample Collected by '~, ~ ~;~--~ I~"r~"~=,'Z~,'~'~-~ ; Date Water Sample Test Results Comments B. SEPTIC/.HOEDtNG'TANK DATA Date Installed ~ Size t~>~.t~!,-~3 No. of Compartments Standpipes {3~N) Air-tight Caps~N) Foundation Cleanout (Y~;~) Depression over Tank (Y/~ Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) Separation Distances from Septic/Hetdm~Tank: To Water-Supply Well ~, ~ To Property Line ~.~:> t ~ To Water Main/Service Line Course~ /~ Date Last Pumped _~::~- · for Temporary Holding Tank Permit (Y/N) To Building Foundation To Disposal Field To Stream, Pond, Lake, or Major Drainage Comments Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed ~::~-~. Width of Field Type of System Design -~-t~.ength of Field (.,-,-,-,-,-,-,-,-~ -3~J ~,,~..~;~ Square Feet of Absorption Area Depression over Field (Y/~;~j> Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well To Building Foundation Lot ~'~/~' To Water Main/Service Line t c::,I ~ To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Depth of Field ~-~..~c,. Gravel Bed Thickness Standpipes Present ~N) Date of Last Adequacy Test To Property Line To Existing or Abandoned System on ' On Adjoining Lots ~ To/Cutbank (if present) Comments D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) /r"Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. signed~,,~ ~ I~I~IQI~IEEI~t~it~ Date ~~_~,-.{"' f'' ":~~ MOA NO. Receipt ~~/~ Date of Payment ~'~'~ Amount: $ ~ Page 2 of 2 72-026 [11/84) APPLIC. FILLS OUT UPPER' HAL: ONLY ' t /. Phone Address Zip Code Address Zip Code Realty Co. & Agent Phone Address Zip Code Street Locati~ '/~., / ." j' ~ ,, · ,,: ' Type of Residence /[~ since Family [] Multiple Family No. of Bedr [] Other Water Supply 1' Individual ATTACH WELL LOG. A well Icg is required for all wells drilled since June 1975. Community For wells drilled prior to that date, give well depth (attach log if available). [] Public Utility Sewer Disposal pi' Individual Year Individual Installed: 'E~ Public Utility When Connected to Public Utility: " [] Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. Time Time Time Time Date Date Date Date (~ Inspector Inspector Inspector Inspector (~) APPROVED BEDROOMS *CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL* ~ Soils Rating Date ~wer Installed Well To Absorption Area / ~ ~ Well Log Received ALASKA eFIUIROFImerlTAL COFITROL SeI UICI $, IFIC. I~,:lin¢¢ri~q 8 ~nuiro~m~Id Studies BRUCE & JUDY CLARDY SRA BOX 2282 ANCHORAGE AK 99507 SELLER - BRUCE & JUDY CLARDY BUYER - SUBDIVISION - CONIFER HEIGHTS BLOCK - 3 LOT - 15 ADEQUACY TEST FOR SEWER SYSTEM THE TYPE OF ABSORPTION SYSTEM IS A TRENCH WITH AN AREA OF 664 SQFT. THE SYSTEM IS CAPABLE OF ACCEPTING 600 GALLONS OF WATER PER DAY. THE SURGE CAPACITY OF THE SYSTEM IS 600 GALLONS. BASED UPON THE TEST DATA THE SYSTEM IS ACCEPTABLE FOR A 4 BEDROOM HOME. SEPTIC TANK ADEQUACY THE EXISTING SEPTIC TANK VOLUME OF 1000 GALLONS IS INADEQUATE BY 250 GALLONS FOR THIS HOUSE OF 4 BEDROOMS. _,...~',~_ OF ~1~,~,,~I ~ ,e- ~ -ee ~ ~" roy C, Reid, Jr, ~ ~ , No 2251.E ., q' '~ · ~ ~ ',. .,* ~x~ ~ 1200 West 33rd Auenue, Suite B ,, Anch0raqe,/~laska 99503 · (907) 276-1361 September 27, 1983 ~{ruce i. and Judy L. Clardy SRA box 2282 Ancl~ora<.je, AK 99507 ~uO3cct: Lot 15, ~lock 3, Conifer Heigi':ts SuOdivision ;\}?provai for the lnoividual sewer and %~ater facilities cannot De ~3ranted untii the following item, s have bee~ completed: The application shows the number of bedrooms exceeds the number the on-site se%~er system was originaily designed for. An upgrade will be required. Prior to any upgrade, a ~ermit needs to be issued from this deparLment. Please noti[y this Department ~or a reinspect~o[~ when the noted discrepancies have beea corrected, i£ there are any further questions, please call this office at 264-4720. Sincerely, · Jim Roberts Associate Environmental S~;eciaiist J~27/eD/E2 , DA'rE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE MI ,NiCi PAii, I~;(tA'~N&ORAGE DEPT. OF I:~",LTH & MUNICIPALITY OF ANCHORAGE ENVIRONMEN1AL ~:.OTECTION ) DEPARTMENT OF HEALTH & ~NV~ RONMENTAL PROTECTION 825 L Street-Anchorage, Alaska 99501 [.~jk~(' ~ ~gs0 ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 R E C E I V E D REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES PI RECTIONS: Complete all parts on page 1, Incomplete requests will not be processed. Please allow ten (10) days for processing. 1, PROPERTYOWNE~ I PHONE ~AILI~G ADDR~S ' P~OPE~YY ~ESlDENT (If different from above} PHONE 2. BUYER PHONE MAI LING, A D DR ESS I 3. ~~LENDING INSTITUTION~ ~Jl ~PHONE~ ~ 5. LEGAL DESCRIPTION STR&'LOCATION 6. TYPE OF RESIDENCE [~"'~1 NG LE FAMILY [] MULTIPLE FAMILY NUMBER OF~BEDROOMS [] One [] Four [] Two [] Five J;;~e [] Six [] Other 7. WATER SUPPLY ~ ~~T. [Z]~INDIVIDUAL* ~-)~ ACH WELL LOG. A well log is required for all wells drilled [] COMMUNITY since June 1975. For wells drilled prior to that date, give well [] PUBLIC UTILITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM ~NDIVI DUAL/ON-SITE** [] PUBLIC UTILITY YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. 6/79) THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE [] SINGLE FAMILY [] MULTIPLE FAMILY 2. WATER SUPPLY [] INDIVIDUAL [] COMMUNITY [] PUBLIC UTILITY Connection Verified 3. SEWAGE DISPOSAL SYSTEM [] INDIVIDUAL/ON -SITE []PUBLIC UTILITY Connection Verified [~]Septic Tank or [] Holding Tank Size: /6~ ~ If Tank is homemade give dimensions: TYPE OF TANK TOTAL ABSORPTION AREA 4. DISTANCES WELL TO: Absorption Area to nearest Lot Line NUMBER OFBEDROOMS [] ONE [] TWO [] THREE [] FIVE [] FOUR [] SIX PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED PERMIT NUMBER DATE INSTALLED INSTALLER SOILS RATING ~'~ MANUFACTURER ~ MATERIAL ~ Septic/Holding Tank IAbsorption Area ISewer Line [] OTHER INearest Lot Line 5. COMMENTS [~'APPROVED FOR ,.~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED BY /"? DATE 72-010 (Rev. 6/79) ' 'M~J-NI'CiI~,LITY OF ANCHO~GE MUNICIPALITY OF ANCHORAGE DEPT. OF I::,%TH & DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTIO~VIRONi¢,ENTAL J~i©-~ [CTJO~ 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL ENGINEERING DIVISION k~AY Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWE~~I~" DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing, [ PHONE PROPERTY RESIDENT (If different from above) -- ~ ~ ~ ~ 2. BUYER PHONE MAI bi NG A DDR ESS 4. REALTOR/AGENT~' I PHONE I MAILING ADDRESS 5. LEGAL DESCRIPTION STREET LOCATION TYPE OF RESIDENCE ~ SINGLE FAMILY [] MULTIPLE FAMILY NUMBER OF BEDROOMS [] One [] Four [] Two [] Five ~ Three [] Six [] Other 7. WATER SUPPLY INDIVIDUAL* [] COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LOG, A well log is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM I N DIVI DUAL/ON-'SITE** [] PUBLIC UTILITY *'If individual/on-site, give installation date ,]t.A 15~_ [/3. If system is over two (2) years old an adequacy test is required by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010(3/78) THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: NUMBER OF BEDROOMS 1. TYPE OF RESIDENCE [] SINGLE FAMILY [] MULTIPLE FAMILY [] ONE [] THREE [] FIVE [] TWO [] FOUR [] SiX 2. WATER SUPPLY [] INDIVIDUAL [] COMMUNITY [] PUBLIC UTILITY Connection Verified 3. SEWAGE DISPOSAL SYSTEM [] INDIVIDUAL/ON -SITE []PUBLIC UTILITY Connection Verified []Septic Tank or [] Holding Tank Size: If Tank is homemade give dimensions: PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED PERMIT NUMBER DATEINSTALLED INSTALLER SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL TO: Absorption Area to nearest Lot Line [] OTHER Septic/Holding Tank IAbsorption Area Sewer Line JNearest Lot Line 5. COMMENTS [~;~APPROVED FOR ~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED BY (Title) ~~ 5---( DATE LEGAL DESCRIPTION 72-010 (Rev. 3/78) '" · iCi-~AO[!, ALASI<A ,~9.01 May 8, 1979 Gregory J. Petro Star Route A Box 73P Anchorage, Alaska 99507 Subject: Lot 15 Block 3 Conifer Heights Subdivision Approval for your individual sewer and water facilities will not be granted until the following items have been completed: (1) The water analysis report be delivered to this office from Chem Lab, 5633 B Street, for our review. (2) Your permit for installation of an on-site sewer system has expired as of December 31, 1978. We have not received the as-builts of the installation in this office. If an engineer inspected the system, please have him send us the report for our review and files. If there are any further questions, please contact this office at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist aCP/ljw cc: Alaska U.S.A. Federal Credit Union 777 Juneau Street 99501