HomeMy WebLinkAboutCONIFER HEIGHTS BLK 3 LT 16Municipality of Anchorage On -Site Water and Wastewater Program - (907) 343-7904 Page 1 of 3 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181024 PID Number 015-093-07 Dwelling: 9 Single Family (SF) nDuplex (D) El Multiple (SF and/or D) Project: F1 New F0_1 Upgrade Name: Doretta Kelley/Michael Hughes Revocable Trust ABSORPTION FIELD El Deep Trench no Shallow Trench [I Bed El Mound Address 9300 Ponderosa Dr. Anchorage, AK 99507 El Other Phone Number of Bedrooms Soil Rating Totaldepth from original grade T1002 (907) 929-5203 14 1.2 GPD/S F I Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 6.2 Ft. Gravel depth beneath pipe .0 Ft. Subdivision Block Lot Conifer Heights 3 16 Fill added above original grade 0.4 Ft. Gravel length 50 Ft. Township Range Section Gravel width 5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist between trenches Tank From Field Tank Line 500 Fe1 Ft. Well >100'1 >100' N/A N/A >251 TANK 9 Septic [:1 S.T.E.P. 0 Holding 0 Other Manufacturer Anchorage Tank Capacity I 1250 Gal. Surface Water >100, >10o, N/A N/A Material Number of compartments LOT Line >5' 3.5'* N/A N/A Steel 2 NA Foundation >10' >10' N N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks *OSV181009 Pump on level at in. Pump off level at High water alarm at Pump make and model lElectrical Inspections performed by Installer PIPE MATERIAL House to tank D3034 Tankto drainfield D3034 A+ Home Services Drainfield D3034 COW j23Qa4 Inspector C. Johansen, J. Millette BENCH MARK (Assumed elevation) 100 ft Insdates: vI ction 3/07/18 20J 3/08/18 d Location and description 3'a 41 Garage Slab COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: Date AW 12� low V . 49 TH ..... .......... • Be ruin Schiier o� CE2592 1 Appr Date3 Approve N—J/ '0 nspection Kepon_v-1-11.aoc CONIFER HEIGHTS B3 L16 PERMIT # OSP181024 PID # 015-093-07 /S: / NEW ABSORPTION TRENCH //N / 5OLF x 5 x 4'EFFECTIVE \ > i PORT ORFORD dRIVE / 10'SLOPE EASEMENT T —� / PERK2 –Q , EXISTING TRENCH • • TH#1 Z I ® • PERK 3 4 1 1 MT 1" ` PERK 1•_ • • DV 001 - \ ', 1250-GAL STEEL TANK SV 2CQ2 •. • O 2C0 7-'4' .7) \ 2 \\ A B 0 2C0 51.9 37.0 4-BDRM HOME \ :- SV1 54.0 39.3 \ SV2 61.5 47.0 I - 2CO2 64.5 50.0 LOT- 1 , - ._ DV 65.3 51.0 , CO1 83.2 79.0 PATIO 1 N>k MT1 84.0 79.0 r / CO2 127.0 117.01 1 / MT2 126.3 116.01 E,10'UTILITY EASENTI\ ' ii/— 7 / j\ EXIrpTING WELL LOT 15 1 / // I ® 1/ / / / / \ �/ I/ // ///I/l NOTE: ��"��xxu, NO SLOPES>25%WITHIN 50'OR SURFACE WATER WITHIN 100'OF THE LEGEND OF AkArkk' PROPOSED SEPTIC SYSTEM• CO CLEANOUT ire. '..1'1 '�y1l 2C0-DOUBLE CLEANOUT j . 7H 1'1 .*�� ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS FCO FOUNDATION CLEANOUT PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC DV FLOW DATLO ER VALVE r. .. SYSTEMS. Benjat ,n Schuler MH MANHOLE �1 PF'• CE 12592 •4 �� 0 50 100 MT-MONITORING TUBE I:' WI 12.2018 PROFESSIONP•��Air: MI MI 11111 MI FEET SV SEPTIC VENT `•�\"`� 1"=50' TH TEST HOLE CONIFER HEIGHTS B3 L16 PERMIT # OSP181024 PID # 015-093-07 cv O O U) (1) N - - 98.3 — — — — — r 93.8 . 7r1 C\\ 93.2 1250 GAL 93.0 SEPTIC TANK kt ''''''' — 88.9 7— 99.OFINISH GRADE 2 98.6 ORIGINAL GRADE Ov if/ 92.4 ORAINFIElO ROCK 92.4 88.4 88.4 50' H NO GROUNDWATER 2/28/18 82.1 r- 4 I— l �i*�P .• TM ` \ .,f9*fie' /i -. Benja Schiller : PROFILE AS-BUILT 0iTh,c.•• Cf ,P2ps2 • \A., (NO SCALE) lV PROFESSIONA�'� GE ENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) March 12,2018 Municipality of Anchorage Development Services Dept-On-Site Water& Wastewater Program 4700 Elmore Rd Anchorage,AK 99507 Subject: Conifer Heights, Block 3 Lot 16—9300 Ponderosa Drive Septic system upgrade and trench re-classification Dear On-Site Services Engineer: The owner of the above lot decided to upgrade their septic system. The original design was for a 3-bedroom home,but at some point in the past a bedroom was added to the house. The upgrade to the septic system included a new trench designed for 4 bedrooms. During design and construction, we dug a new test hole and performed three perk tests. All three benches perked at between 1-5 minutes/inch,including a test done right next to the existing trench. This trench was designed for a perk rate of 5.7 min/in. We have included the new perk tests and are asking for this trench to be accepted at the new perk rate of 1.2 min/in. The existing trench is 40' long, 7' effective depth, for a total absorption area of 560SF. With the new perk rate,the application rate of 1.2 GPD/SF makes the existing trench acceptably sized for a 4-bedroom home. With this adjustment, this trench will be able to be tested for the COSA as needed in the future. Sincerely, .. •" 4, ?*149TH i :* r Benjamin Schiller, PE Benja in Schiller : 'Vs. CE 12592 / 'ffF • '3 u fi�t$.•'a�,r +,l�F�PROFESSIONP\c ltd\\\S.L�4 MUNICIPALITY OF ANCHORAGE9FAqt;1k' DEVELOPMENT SERVICES DEPARTMENT ''r 4 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 it:STM \ *t� SOILS LOG AND PERCOLATION TEST .. Benj in Schiller t't-P•• CE 12592 ` - LEGAL DESCRIPTION: CONIFER HEIGHTS B3 L16 �1t1`\PROFESSIONP-� PERFORMED FOR: NN:W. DATE: 3/9/2018 PROJECT No.: Professional Engineers Stamp: PARCEL ID#: 015-093-07 TECHNICIAN: C. JOHANSEN DEPTH PERK #3 (feet) 1 SLOPE SITE PLAN 2 3 4 5 SEE SITE PLAN 6 1 7 8 9 10 WAS GROUND WATER ENCOUNTERED? IF YES L WHAT DEPTH? 11 DEPTH OF WATER AFTER MONITORING: DATE OF MONITORING: 12 GROSS TIME NET TIME DEPTH TO NET DROP 13 DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 14 3/9 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 1 1230/ 1236 6:05 0/6M 6.00 16 2 12:07/ 12:13 6:10 0/6.0 6.00 3 12:14/ 12:20 6:20 0/6.0 6.00 17 4 12:21 / 12:28 7:03 0/6.0 6.00 18 5 1229/ 1236 7:04 0/6M 6.00 19 6 12:37/ 12:44 7:04 0/6.0 6.00 20 PERCOLATION RATE: 1.2 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: Municipality of Anchorage { ICALION; Mien P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http:l/www.muni.orq/Onsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV181009 COSA#: Permit#: OSP181024 PID#: 015-093-07 Legal Description: Conifer Heights B3 L16 Engineer: Forge engineering Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 3.5 feet. This waiver approval applies to the existing absorption field only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: 3/�0 , Approved by: M00144 zc �8 _ Name of Rev' er **** VARIANCE/WAIVER REVIEW **** GE INGINCERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) March 19, 2018 Municipality of Anchorage Development Services Dept- On-Site Water& Wastewater Program 4700 Elmore Rd Anchorage,AK 99507 Subject: Conifer Heights,Block 3 Lot 16—9300 Ponderosa Drive Lot Line Waiver Dear On-Site Services Engineer: The owner of the above lot has installed an upgrade for their septic system. Unfortunately, when the final measurements were taken, it turns out that the end of it was put in closer than 10' to the lot line.The lot line is adjacent to the Port Orford Drive ROW,and will not impact the neighboring property at all. The trench also will not impact the property to the north across the ROW, and is not affected by the existing well on that property. We request that a waiver be issued for a 3.5' separation to the lot line. Sincerely, 4.0``NNN OF Aqq k i�P• Benjamin Schiller, PE OI j* TM •�c '*" Benja ' • chiller :1j � CE 12592 fi e*•• 3/198,.•� _� ikiFipRGfESS10Na�.. w �civeurr ,�"" �. �' MUNICIPALITY OF ANCHORAGE enc , On-Site Water&Wastewater Program �o'm Se PO Box 196650 4700 Elmore Road c.. I. P. , - Anchorage,Alaska 99519 6650 Phone:(907)343-7904 Fax:(907)343-7997 ,N ...r,� � "� jjj http//www.muni.org/onsite . -.: r' SNC 1)(.'l lil P t Ol ell On-Site Wastewater Disposal System Permit 3/g/10 j0/.#,Tai k v- Ta,pp:p _ Permit Number: OSP181024 Effective Date: 3/2/2018 Work Type: Septic Upgrade Expiration Date: 3/2/2019 Tax Code Number: 01509307000 Site Legal Address: CONIFER HEIGHTS BLK 3 LT 16 G:2440 Site Mailing Address: 9300 PONDEROSA DR, Anchorage Owner: KELLEY DORETTA L& Lot Size in Sq Ft: 34921 Design Engineer: FORGE ENGINEERING Total Bedrooms: 4 This permit is for the construction of: 0 Disposal Field Q Septic Tank ❑ Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: �/ Q/I /T11.(1. vUL ,f_ Date: 3 5 Issued By: `>°,{+,r,ti 6,n, Date: 3Arje PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) February 27, 2018 Municipality of Anchorage Development Services Dept- On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Conifer Heights, Block 3 Lot 16 – 9300 Ponderosa Drive Septic system design and permit application Dear On-Site Services Engineer: The owner of the above lot has decided to upgrade their septic system. The current design is for a 3 -bedroom home, but at some point in the past a bedroom was added. We are submitting this permit to replace the septic tank and build a new field. The attached site plan identifies the location of the home, well, septic tank, and existing field, as well as the proposed field. No conflicts exist between this proposed system and any wells, whether on this lot or adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction of flow. The drainage pattern in general will not be changed by the construction. The test hole recently placed on the lot indicates silty sand with some gravel (SP-SM), but that is under about 5.5 ’ of fill and organics. No bedrock was found down to 16.5 ’ and no groundwater. The percolation rate of the soils under the fill was tested at 2.4 min/in, so an application rate of 1.2 gpd/sf was used in the design of the new absorption trench. We are proposing a 5-wide trench, 4’ effective depth, with a total length of 50’. The elevation of the distribution line will be 6’ below the surface for a total depth of 10’. Soil will be mounded slightly above the trench to prevent water from ponding above it. The 1000-gallon septic tank will be removed and crushed. A new 1250-gallon tank will be placed in the same spot. A minimum of 4’ of cover will be placed over the tank, or 2’ of cover and 2” of insulation. A double cleanout will be placed after the tank along with a flow diverter valve. The existing trench will remain connected to the system with the valve, allowing it to recover for future use. The ground surface on the lot slopes moderately toward the northwest, between 8-10%. There are no steep slopes anywhere on the property. The new trench will be constructed parallel to the slope as much as possible. It will be a minimum of 100’ from all wells and surface water, more than 5’ away from the septic tank, and more than 14’ from the existing trench. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181024, Rebecca Carroll, 03/02/18 If the system is constructed as designed, it will have no adverse impact: • On the wells in the area or those to be constructed in the future. • On existing septic systems in the area or those to be constructed in the future. • On reserve space on any lots located in the area. • On drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Benjamin Schiller, PE 2/27/18 // // // x x // // // //2CO 10050 0 FEET 1"=50' 4-BDRM HOME EXISTING WELL NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT DV - FLOW DIVERTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND CO TH#1 CONIFER HEIGHTS B3 L16 Feb 28, 2018 PONDEROSA DRIVEPORT ORFORD DRIVE EXISTING TRENCH 40LF x 3' x 7' EFFECTIVE ALTERNATE SITE W/ ADVANTEX SYSTEM (8.6 LF x 3' x7' REQ'D) 10' UTILITY EASEMENT PATIO PERK 1 PERK 210' SLOPE EASEMENT REMOVE AND DISPOSE OF EXISTING SEPTIC TANK OR CRUSH AND BURY IN-PLACE. REPLACE W/ NEW 1250-GAL STEEL TANK NEW ABSORPTION TRENCH 50lf x 5' x 4' EFFECTIVE NEW DIVERTER VALVE CO MT 8-10% 8-10% 8-10% 2COPROVIDE DOUBLE CLEANOUT BEFORE SEPTIC TANK Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181024, Rebecca Carroll, 03/02/18 CONIFER HEIGHTS, BLOCK 3 LOT 16 DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: 2.4 MIN/IN APPLICATION RATE: 1.2 GPD/SF 5' WIDE DEEP TRENCH SYSTEM 1,250-GAL SEPTIC TANK 600 GPD / 1.2 GPD/SF / 5' WIDE * 0.5 REDUCTION FACTOR = 50 LF REQUIRED NOTES: GRADE AREA OVER TRENCH TO DRAIN AWAY MIN 6' SEPARATION FROM BEDROCK MIN 4' SEPARATION FROM GROUNDWATER MIN 100' SEPARATION FROM NEARBY WELLS MIN 100' SEPARATION FROM SURFACE WATER OR STREAMS 5-WIDE TRENCH SECTION (NO SCALE) THEREFORE: CONSTRUCT AN ABSORPTION TRENCH 50' LONG x 5' WIDE x 4' EFFECTIVE DEPTH. FLOW LINE ELEVATION IN TRENCHES TO BE 6' BELOW ORIGINAL GROUND SURFACE. TOTAL DEPTH TO BE 10' BELOW EXISTING GROUND. PROVIDE 3' COVER OVER TRENCHES AND 4' COVER OVER SEPTIC TANK, OR INSULATION WITH 2' COVER. 5' Feb 27, 2018 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 6" 5.5' 4' Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181024, Rebecca Carroll, 03/02/18 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TH#1 PERK#1 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) Conifer Heights B3 L16 2/21/2018 J. Millette Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? NO none 1:00/1:10 2/21 1 2.4 6 6 7 2 1' OB 015-093-07 3 4 5 6 6 Professional Engineers Stamp: Feb 28, 2018 fill (SM w/ waste - stumps & branches) Organics (pt) silty sand w/ some gravel (sp-sm) more cobbles w/ depth 10 5 1 4 / 11 1 4 1:10/1:20 610 5 1 4 / 11 1 4 1:20/1:30 610 5 1 4 / 11 1 4 1:30/1:40 10 5 1 4 / 9 1 2 4 1 4 1:40/1:50 10 5 1 4 / 9 1 2 4 1 4 1:50/2:00 10 5 1 4 / 9 1 2 4 1 4 none 2/28/18 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181024, Rebecca Carroll, 03/02/18 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: PERK #2 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) Conifer Heights B3 L16 2/21/2018 J. Millette Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? 1:05/1:15 2/21 1 2.2 6 6 7 2 015-093-07 3 4 5 6 Professional Engineers Stamp: Feb 27, 2018 10 5 1 4 / 10 3 4 1:15/1:25 10 5 1 4 / 10 1 2 1:25/1:35 10 5 1 4 / 10 7 16 1:35/1:45 10 5 1 4 / 9 1 2 4 1 4 1:45/1:55 10 5 1 4 / 9 1 2 4 1 2 1:55/2:05 10 5 1 4 / 9 1 2 4 1 2 5 3 16 5 1 4 5 1 2 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181024, Rebecca Carroll, 03/02/18 , ~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME~ [] UPGRADE "' DISTANCE TO: IW''', /ZO' [ Abs~n area Dwelli~ ~1' PERMIT NO. '<~ ~ Manufacturer ~~ Mat~~ ,o.~com~artm.nts in gallons Inside length Width Liquid depth ~/ IF HOMEMADE: ~ ~ DISTANCE~O: Well Dwelling PERMIT NO. =-~OZ~ Manufacturer ~ ~~ ~iquid ca~acitg in ,allons ~ DISTANCE TO: Length~h I~-~ Total~ I~'-- ~r~h Distance between lines ~Z~ N°. °f lines ~ inches To~ti~ption ~ Top~f.tile to fin~[h ~ade~l area OTHE~ SOl L TEST RATING I~ INSTALLER REMAR~s /,- . 72-013 (Rev. 3/78) PERMIT NO. r'lLIF~ ICI ! ~LIT'~ I2F R~I~H ~:RGE DEPRRTMENT OF-,~ERLTH 8ND ENVIRONMENTBL F'NOTECTION 825 ~L~ STREET, 8NCHORRGE~ RK. 99501 264-4720 P4ELL Rr~E:, Of-$--,~ITE '__~EPSER P ERF1 IT ( 78100i ) 8PPLIC8NT LOCRTION LEGRL SRM HILL PONDEROS8 L16 B3 CONIFER HTS SRR BOX ?2-H 99507 LOT SIZE ~49 4747 ~8000 SQURRE FEET TYPE OF SOIL RBSORBTION SYSTEM IS: TRENCH MB~IMUM NUMBER OF BEDROOMS SOIL RRTING THE REQUIRED SIZE OF THE SOIL RBSORPTION SYSTEM IS: [~.EPTH= ~L2 LENGTH= ~_'_B GRF~b'EL C. EPTH= ? THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRBINFIEL[). THE DEPTH OF ~ TRENCH OR PIT IS THE DIST8NCE BETWEEN THE SURFBCE OF THE GROUND 8ND THE BOTTOM OF THE EXCRV8TION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GR8VEL BETWEEN THE OUTF8LL. PIPE RND THE BOTTOM OF THE E~C8¥RTION (IN FEET). ~:E[qLI I REC, SEPT I E: PERMIT 8PPLICRNT HRS THE RESPONSIBILITY TO INFORM THIS DEPBRTMENT DURING THE INSTRLLBTION INSPECTIONS OF 8NY WELLS 8DJBCENT TO THIS PROPERTY RND THE NUMBER OF RESIDENCES THRT THE WELL WILL SERVE. TP~£~ (2) I F~$PEC:TIO~$ R~:E RE~21_II ~:E[) BRCKF'ILLING OF 8NY SYSTEM WITHOUT FINBL INSPECTION 8ND RPPROVBL BY THIS DEPRRTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTBNCE BETWEEN 8 WELL 8ND 8NY ON-SITE SEWBGE DISPOSBL. SYSTEM IS 100 FEET FOR 8 PRIYBTE WELL; OR 150 TO 200 FEET FROM 8 PUBLIC WELL DEPENDING UPON THE TYPE OF PUBL. IC WELL. WELL LOGS 8RE REQUIRED 8ND MUST BE RETURNED TO THE DEPBRTMENT WITHIN ~0 DBYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MBY 8PPLY. SPECIFICBTIONS 8ND CONSTRUCTION DIAGRBMS 8RE 8VBILBBLE TO INSURE PROPER INSTBLLBTION. F'ERM I T E)<P I F~:E$ DECEMBER I CERTIFY THBT :1.: I 8M FRMILIBR WITH THE REQUIREMENTS FOR ON-SITE SEWERS 8ND WELLS RS SET FORTH BY THE MUNICIPBLIT't~ OF 8NCHORBGE. .- '=. 2' I WILL INSTBLL THE SY-~;TEM IN 8CCORDBNCE WITH THE [.ODE_. I UNDERSTB~_~BT , j~ , THE ~N-SITE SEWER S~STEM MB~ [E~iI[E ENLBRGEMENT I F THE / /._ /~i'''°';, GREATER ANCHORAGE AREA BORO' 'GH it1 Departmeni: of Environmental Quality 3330 "C" Street  Anchorage. Alaska 99503 , SOILS LOG -- PEROLAT'ON TEST Performed for ~,~A .... ? ~C~ Date Legal Description:L~/~, ~'~ 3, C~~j~~~~%, ~'(~ This form repo~s: Soils log T~-~ ~)-~ U~z~c~O Percolatio,-, ~est ~~ Was groundwater encountered? /lO¢ ~/.T, ~tkYZ)U~yes, atwha'tde3th? ~ Reading Date Gross Time Net Time Depth to Water Net Drop ..... ~ ,, _ 7 ..... ', / ...... ?~ ~ ~,% Proposed installation: ~eepage ~¥1d %~~:~ Depth of Inlet . Depth to bottom of pit or trench '~ COMMENTS: _(~_..."~/~;~ ~-~v.-~_. F~c.t ~ ~0 l% ~~ ~f~~.~~' P~UL O. HANS'~N, P.~. SR~ BOX 395-V ANCHORAGE, ~L~SKi 99507 April ~1, 1978 ~,~r. Sara P. Hill BRA Box 72H Anchorage, Alaska 99507 Dear )~r. Hill In accordance with your request~ have co~ed s~ils analyses for ¢ on-site sewage disposal on notF 3; Co ife eight Subdivision, Anchorage. Drillt~ consist.~of three test holes, was performed on k%rch 28, 1978 by Denali Drilling, Inc. of Anchorage em- ploying a B-50 Mobile drill; logging and percolation testing were per- formed by myself in accordance ,~ith the Unified Boil Classification System, the Boil Triangle, and. the "SIanual of Septic-Tank Practice". All three test holes were saturated at least 24 hours prior to the test. The attached sheets detail the results. As is typical with soils in the O'.~.'~lley-Hillside area, the encountered soils consisted generally of glacial drift composed of a mixture of silt, sand, and gravel. The silt component has a large influence on 'the per- colation rate, measured to be 135, 155, and ~00 sq ft/bedroom. test holes (TH 1&3) suffered some sloughing during percolation, so two tests were repeated, vzJ. th water levels determined by means of a 1" perforated plastic pipe installed immediately after drilling/ The three lots are amply covered'~ith large spruce and birch trees, in- dicative of good drainage; however, the drainfield trench for Lot 5 ' should be located slightly southwest of TH t, and about 5 feet higher in elevation in order to avoid potential seepage from a nearby low a~ea that has no outlet. During breakup, water could collect in this low area and be detrimental. In my opinion, the three lots appear satisfactory for on-site sewage disposal, in terms of topography, drainage; and soil percolation. t Paul G. Hansen MUNICIPALITY OF ANCHORAGE o Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I. D. 015-093-07 Legal description CONIFER HEIGHTS BLK 3 LT 16 Site address 9300 PONDEROSA DR Anchorage AK Current property owner(s) SELLERS Expiration Date: 4/22/2025 X The On -site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: Original Certificate Date: 5/31 /2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory X Tank Age Advisory Arsenic Advisory Other COSA Approval June 2022 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax. 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I. D. 015 093 07 Complete legal description CONIFER HEIGHTS BLK 3 LT 16 Location (site address) 9300 Ponderosa Current property owner(s) Sellers 2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: ■❑ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: X Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑■ Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age 6 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ❑E Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ �SO Waiver Fee $ Date of Payment 5� f2 `l c� Date of Payment COSA # C) Waiver # COSA Application —June 2022 Nitrate Advisory Certificate of On -Site Systems Approval # OSC241140 Subdivision: CONIFER HEIGHTS, Block: 3, Lot: 16 A water sample revealed a nitrate concentration of 7.65 milligrams per liter (mg/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Since nitrates are known to slowly increase, we recommend you monitor the water quality. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. :r` � Mailing Address P-O` Box�.96650 *:Anchorage; Alaska 99519 6650 �` www murn org From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. Mailing Address P O Boxk1966S0 *Anchorage, Alaska 9951946650 *£www mum org z COSA Checklist_June 2022 COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: COSA Checklist_June 2022 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F.ENGINEER’S COMMENTS G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Phone Engineer’s Printed Name Date C&M ENGINEERING CHARLES BALZARINI, PE 5/12/24 Development Services Department �� 7 Phone: 907-343-7904 On -Site Water & Wastewater Section --- Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 015-093-07 1. GENERAL INFORMATION Expiration Date: _/®^!J ^2® Z7-- Complete Z Complete legal description Conifer Heights Block 3 Lot 16 Location (site address) 9300 Ponderosa Drive Current property owner(s) Neal & Erica Fossler Mailing address Real estate agent 9300 Ponderosa Drive Teresa Bell 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Day phone (907) 350-0151 Day phone (907) 240-2248 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well Q Private Septic ❑■ Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 550 Waiver Fee $ Date of Payment G' Q c2 9 C a Date of Payment Receipt Number .3� Receipt Number COSA # _ 05Laa 13 � � Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone (907) 522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503 Engineer's Printed Name Benjamin Schiller, P.E. Date 06/20/22 OF q�p � 6. DSD SIGNATURE ' / ........... System #1 Approved for i bedrooms Benjarr�r t5chi11er .: System #2 Approved for bedrooms <`c�s., CE 12592.06/20122, 2592 ��Aw ��. • 06/20/22 , • •�c� ,®. Disapproved ����F�pROFESSIOHP� ��° Conditional approval for bedrooms, with the following stipulations: ON- "'��1.�1)))))11117. BY Original Certificate Date: —7– The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet Legal Description: Conifer Heights Block 3 Lot 16 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 05/16/78 Total depth 350 ft Cased to U N K ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 24 in. Date of flow test for COSA 05/31/22 Static water level at beginning of test 230 ft. Comments B. TANK DATA Age of tank(s) 4 years Tank type/material SEPTIC/STEEL Measured operating fluid level in septic tank 48 no Standpipes/foundation cleanout per record drawing Date of pumping 6/27/22 A+ Home Services D. ABSORPTION FIELD DATA Which system tested (date installed) 03/08/18 ❑ ALL standpipes present per record drawing Total measured depth from grade 9.1 ft (max) Measured depth to pipe invert from grade 5.0 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective 4.1 ❑ Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced N/A gallons Comments/Deficiencies: COSA Checklist yellow sheet Parcel ID: 015-093-07 Structure served by this system Well production at time of test 3.8 gpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate -1 -82 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Forge Engineering Date of Sample C. LIFT STATION 06/01/22 red maintenance completed Age of lift stati lr-,_ years Lift station material ____1 Comments: Adequacy test date 05/31/22 Results Q✓ Pass For 4 bedrooms Fluid depth prior to test 6 in Water added 671 gal New depth 9 in Elapsed time 1440 min Final fluid depth 4 in Absorption rate '600 gpd Any rejuvenation treatment (past 12 months) N/A If yes, enter date N/A E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100' ❑✓ Yes if No ft F1 Yes if No ft Neighboring Tank > 100' F71 Yes if No ft Private Sewer/Septic Line > 25' ❑✓ Yes if No ft Absorption Field on Lot > 100' ❑✓ Yes if No ft Holding Tank > 100' n✓ Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' 0✓ Yes if No ft 0 Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' Q Yes if No ft 0 Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ✓M Yes if No ft Surface Water > 100' Q Yes if No ft Property Line > 5' El Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' Q Yes if No ft Private Wells > 100' n Yes if No ft Water Main > 10' F/I Yes if No ft Community Wells > 200' 0 Yes if No ft Water Service Line > 10' [Z] Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ✓[] Yes if No ft If absorption field is under driveway comment below Property Line > 10' C Yes if No 3.5* ft Wells on Adjacent Lots: Water Main > 10' ❑✓ Yes if No ft Private Wells > 100' []✓ Yes if No ft Water Service Line > 10' 0 Yes if No ft Community Wells > 200' []✓ Yes if No ft Surface Water > 100' ✓Z] Yes if No ft F. ENGINEER'S COMMENTS OSV181009* G. ENGINEER'S CERTIFICATION l certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet • TH '. •,�.-tom :--:-�.... f`��.,...�,, . �:. . . Ben* nio&hiller CE 12592 Y� �`r%F�• . 06l21t22, - **2 FESSO�— CE" eV •i f rMunicipality of Anchorage --41N- On-Site Water and Wastewater Program (907) 343-7904 Certificate of On-Site Systems Approval Parcel I.D. 015-093-07 Expiration Date: 2_1 -1 6 1. GENERAL INFORMATION Complete legal description Conifer Heights Block 3 Lot 16 Location (site address) 9300 Ponderosa Dr. Current Property owner(s) Doretta Kelley&Michael Hughes Revocable Trust Day phone (907) 929-5203 Mailing address 9300 Ponderosa Dr. Anchorage, AK 99507 Real Estate Agent Day phone 2. TYPE OF DWELLING: H Single Family (w/wo ADU) ❑ Duplex L] Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well H Individual H Individual Water Storage PI Holding Tank ❑ Community Class Well I I Community ❑ Public Water System i i Public Sewer C WaiverNariance request for: Distance: Received by: Date: COSA to be released t the engineer,unless otherwise requested by the engineer. COSA Fee $ aio3• Waiver Fee $ Date of Payment 31140 Date of Payment Receipt Number 00 (gar) Receipt Number COSA# O5(-I IOq`I Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone (907) 522-7773 Address PO Box 240773, Anchorage, AK 99524 Engineer's Printed Name Benjamin Schiller, PE Date 3/12/18 *•' TH 6. DSD SIGNATURE / -•* System #1 Approved for bedrooms "' ••••, BerOml Schiller / System#2 Approved for ' CP �2ss2 i bedrooms Disapproved Conditional approval for bedrooms, with the following stipulations: \••Y 01-446' 0,0 ON-SITE WATER AND ` m WASTEWATER g,- T, PROGRAM OJ G By' Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_t' c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Conifer Heights Block 3 Lot 16 Parcel ID: 015-093-07 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 5/16/78 Sanitary seal (Y/N) Y Wres properly protected (Y/N) Y Total depth 350 ft. Cased to U n k ft. Casing height(above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 5/16/78 3/12/18 Static water level 226 ft. 232 ft. Well production 3 g.p.m. 3.25 g.p.m. WATER SAMPLE RESULTS: Coliform Neg colonies/100 mL Nitrate 5.29 mg/L Arsenic ND ug/L Date of sample: 2/28/18 Collected by: Forge Eng. B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 3/08/18 Tank size 1250 gal. Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout(Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping Pumper New Construction C. ABSORPTION FIELD DATA Date installed 3/08/18 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2 GPD/SF System type 5-Wide Length 50 ft. Width 5.0 ft. Gravel below pipe 4.0 ft. Total depth 10.6 ft. Eff. absorption area 500 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Const. Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100 On adjacent lots 100 Absorption field on lot 100 On adjacent lots 100 Public sewer main >75' Public sewer manhole/cleanout 100 Sewer/septic service line >25' Holding tank >75' Animal containment areas >50' Manure/animal excrete storage areas 100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation �' Property line >5' Absorption field >5' Water main Water service line >10' Surface water >100' Wells on adjacent lots >100 ABSORPTION FIELD ON LOT TO: >10'Property line Building foundation 10 Water main �10 Water Service line 0 Surface water 100 Driveway, parking/vehicle storage 10 Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION ���NtaNNA, I certify that I have determined through field inspections and w4 ' .•• X9+1 review of Municipal records that the above systems are in 04:49 m •••*0l conformance with MOA COSA guidelines in effect on this date. IA Engineer's Printed Name Benjamin Schiller, PE / „ •. 3/12/18 B min Schiller Date �� �w/• 1 .• C 1 592 �,� COSA brown sheet 10-10-12.doc MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT i • �t�i 907-343-7904 On-Site Water and Wastewater Section Fax: 343-7997 www.muni.org/onsite -�- Nitrate Advisory Certificate of On-Site Systems Approval # OSC181084 Subdivision: Conifer Heights, Block: 3, Lot: 16 A water sample revealed a nitrate concentration of 5.29 milligrams per liter (mg/L). The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On-Site Systems Approval. Mailing Address: P.0. Box 196650 *Anchorage,Alaska 99519-6650 *www.muni.org Nitrate Fact Sheet From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen,which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids,and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. Mailing Address: P.0.Box 196650*Anchorage,Alaska 99519-6650 *www.muni.org PORT ORFORD DRIVE POST & RAIL FENCE ` c� 1 — ,---\--- - o 0 0 0 0 o N 88'13'00"E 116.84' L 69i ‘1\ •Sg. '� - r �\\sp J 7 o O -z I 10' SLOPE \ O. 1 ril EASEMENT 0 to N (� 4. U'_ SEPTIC r? .37 PIPES o O 1 � L \ ill rn / 2.0'x9.0' CANT w - O ,• \\\��/.. °ASPHALT •.:- o o �� Lot 17 0 .yti• • , DRIVITWAY ... / 0 20.1' .,,`ti. ,17\ 00.5' / o 1 STORY RESIDENCE �1, I o0 �w/ FULL BSMT. 2.0'x 1 5.0\BALCONY z + `�. / `;• > Pry In / N1\, TO. ti \ IN II / 2.0'x1 1.1'— A DECK CANT Lot 1 6 \ I _ �i 34,921 s.f. Lei m � oo -1)- �—WOODEN FENCE 1 JII I -- CHAIN—LINK 0 1 1 FENCE I WELL -�. '100' PROTECTIVE RADIUS _Lke,Z ,, 1 / / i N 90'00'00'V 175.00' /—/---/ / GUY WIRE / 10' UTILITY EASEMENTS / / / /\ Lot 15 / / / \ / / . 2s o, ,/ PLOT PLAN AS BUILT X SCALE 1" = 40' GRID SW 2440 Project No. 18-081/R1 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates , inc . (907) 522-6476 Phone (907) 522-4625 Fax opo F C1, Professional Land Surveyors kenOlangsurvey.com v ,9 jonathanOlangsurvey.com S nn I hereby certify that I have surveyed the following described property: ,OIC/) 1\ �OV LOT 16, BLOCK 3, CONIFER HEIGHTS (PLAT No. 71-190) *: 49TH �� � P�D Anchorage Recording District, Alaska, and that the Improvements situated thereon areo within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed °O.43'?.. KENN LAN' • cr premises and that there are no roadways, transmission lines or other visible ^ �, easements on said property except as indicated hereon. QA ... )�,(,(1A% .•' oo°0 VO4 'PF '••.LS-5202.••' c.;),,,,,'-- Dated ,Jp Dated this the �'`�� Day of I`i'',i.'L'-�', , , at Anchorage, Alaska 0 �, , • .1oo 4 OPESSIONAk.�. It is the responsibility of the owner to determine the existence of any easements, �D�O�O' . covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963 Municipality of AnChorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 ' ?~ / ~// www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-093-07 1. GENERAL INFORMATION cos^ 0.5C Expiration Date: Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address CONIFER HEIGHTS S/D; BLOCK 5, LOT 16 9300 PONDEROSA DRIVE * ANCHORAGE, AK * 99507 BART RUTTAN Day phone 346-1994 9500 PONDEROSA DRIVE * ANCHORAGE, AK * 99507 Day phone dANET BORDEREAUX W/ DYNAMIC Day phone 244-5456 5111 C STREET * ANCHORAGE, AK * 99505 Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: 5 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well · Individual On-site Individual Water Storage [] Individual Holding tank Community Class Well [] Community On-site Public Water System [] Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On:Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipafity of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorOugh, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use Of this report by any · other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE l/Approved for Disapproved. Conditional approval for __ bedrooms. bedrooms, with the following stipulations: rness..' k ~ ess~q~( ( i(l' ~ ON-SITE ~ j WATERAND ~ : WASTEWATER ~ · PROG~B ~.'~. '.. ..' Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory (Rev. 11/05) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other G-<~/~ Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700. Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.rnuni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Legal DeScription: CONIFER HEIGHTS CHECKLIST BLOCK 5, LOT 16 ParcellD:~)l_~-O~-07 SURROUNDING WELL LOGS. SEE ATTACHED. Well Log (Y/N) YES Wires properly protected (Y/N) YES Casing height (above ground) 12+ AT INSPECTION 9/1/2010 2,31 .ff. 2.83 g.p.m. S/D; UPON Collected by: *4" ABS CLEANOUT IN GARAGE. INSPECTED VIA CAMERA BY MCDONALDS PUMPING. A. WELL DATA *ASSUMED BASED Well type PRIVATE If A, B, or C provide PWSID# N/A Date completed 5/16/1978 Sanitary seal (Y/N). YES Total depth 350 ft. Cased to *40+ .ft. FROM WELL LOG Date of test 5/1 6/1978 Static water level 226 ft. Well production 3 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi. Nitrate~,,'~Smg./L. Arsenic: J~ IF~ugJL. Date of sample: 9/1/2010 B, SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Tanksize 1000 gal. Number of Compartments 2 Foundation cleanout (Y/N) *YES Depression over tank (Y/N) NO Date of pumping 5/6/2010 Pumper C, ABSORPTION FIELD DATA ~'BELOW EXISTING ~RADEI Date installed 6/1/1978 Soil rating (g.p.d./ft2o~ 135 Length 40 .ff. Width 3 ff. in. System type TRENCH Gravel below pipe 7 .ft. Depression over field NO For 3 bedrooms New depth 61 in. in. Absorption rate >= 450+ g.p.d. NONE KNOWN If yes, give date - Total depth ~~[t. Eft. absorption area 480 ft2 Monitoring tube YES Date of adequacy test 9/'1/'2010 Results (Pass/Fail) PASS Fluid depth in absorption field before test 52 in. Water added 740 gal. Elapsed Time: 120 min. Final:fluid depth 57 Any rejuvenation treatment (past 12 mo.) (Y/N & type) NOTE: SUMP ONLY EXTENDS 76" BELOW DRAINPIPE. TOTAL DEPTH IS CALCULATED. NOTE: SMALL PORTION AT NORTH END OF TRENCH APPEARS TO HAVE INADEQUATE SOIL COVER. NO FREEZING ISSUES HAVE BEEN'REPORTED BY HOMEOWNER. Date installed 6/'1/1978 Cleanouts (Y/N) YES High water alarm (Y/N) A+ HOME SERVICES Other bacteria LJ colonies/lO0 mi. GEG Ltd. D. LIFT STATION Date installed "Pump on" level at in. ~ ~ Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Size in gallons Manhole/Access ~ ~ "Pump off" level_~----~ High water alarm level at 100'+ Septic tank/lift station ,on lot Absorption field on lot, 100'+ Public sewer main N/A Sewer/septic service line 25'+ Animal containment areas 50'+ in. Meets alarm & circuit requirements? On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas N/A 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Water main N/A Water service line, 10'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Absorption field 5'+ Surface water. 100'+ Property line Water service line Curtain drain NONE F. COMMENTS 10'+ 10'+ KNOWN Building foundation 10'+ Surface water 100'+ Wells on adjacent lots. 100'+ Water main N/A Driveway, parking/vehicle storage 10'+ G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date oJ/~t~//~ COSA Fee $ a,eo,.a.men, Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 9951%6650 www.muni.org/onsite (907) 343-7904 Nitrate Advisory Certificate of On-Site Systems Approval # 101206 A Certificate of On-Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 3, Lot 16 of Conifer Heights subdivision. This inspection revealed a nitrate concentration of 8.35 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval. .$ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D.# ~_.~' t ~'- CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING · ~-'~l ~ '--O "~"' HAA # '~ i GENERAL INFORMATION Complete legal description Location (site address or directions) c~'~OO Property owner Mailing address Day phone Lending agency Mailing address Day phone Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA #21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Phone "~ > ~''' ~'/'7C~' Address bedrooms. Date Engineer's signature DHHS SIGNATURE v Approved for '~' ~'~ :- ! Disapproved. Conditional approval for bedrooms, with the following stipulations: Note: The we]_], for th±s property meets existing State and Municipal Codes. There are nitrates present. It is suggested that periodic testing be performed to insure the wells continued suitability. Current nitrate connentratffon i,~ 5.67 mg/]. EPA maximum concell~a~io~ i8 10,0 mg/1. More information on nitrates is available from the On-site Services Program, DHH~, 31~3-1~71~/~. Additional Comments ~ ~ :"~' '~ : ' -~: : "~ ' ~ ' ': ~:~"~ ~ ' ~ ~ ' ~ I "X , , '",. The Municipality of Anchorage Department of Health and Human Sewices (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91) Back MOA Alaska Water & Wastewater 7320 East Chester Heights Circle ~ Anchorage ~ Alaska 99504 (907) 33%6179 ~ Fax (907) 338-3246 Consulting Engineers June 27, 1998 Municipality of Anchorage Departmem of Health & Human Services Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 RECEIVED dUN 2.9 1998 Municipality of Anchorage Dept. Health & Human Services Attn: Donna Mears Ref: Release of Conditional Health Certificate for Confier Heights, Lot 16, Bk 3 Dear Ms. Mears: The depression near the clean-out at the beginning of the trench has been filled in. At this time, we are requesting that you issue a non-conditional HAA. If you have any questions, please contact me at 337-6179,.or 244-9612. Thank you for your assistance. Sincerely, Jeffi'o '~ G~ness, PT'_'_'_E., U.S. Princi ~al MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING "GENERAL INFORMATION Complete legal description Location (site address or directions) e Property owner Mailing address Lending agency Mailing address Day phone ('_.._~0~) Day phone Agent Address Es?'. Co, Day phone ~;~4~ Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: ~' TYPE OF WATER SUPPLY: Individual well ~ Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA 5. STATEMENT OF INSPECTION BY ENGINEER. As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe; functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. -. . . .. Name of Firm Address Engineer's signature DHHS SIGNATURE Approved fOr bedrooms. Phone Date I 7~ /14'/C1'~ Disapproved. bedrooms, with the following stipulations: Money shall be put in escrow to correct the depression over the trench. The above work. shall be completed by no later than June 15, 1998. Money in escrow shall not be re%~ased until this office has given final approval. Additional Comments The well for this property meets existing State arid Municipal Codes. There are nitrates present. It is suggested that periodic testing be performed to insure the wells continued suitability. Current nitrate concentration is 5.67 mg/1. E~A maximum concentration is 10.0 mg/1. More information on nitrates is available from the On-site Services Program. By: DHHS, 343-4744. ,t~~C. ~J2~ Date The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025(Rev. 1/91) Back MOA#21 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division 825 L Street, Room 502 · Anchorage, Alaska 99501 ° (907) 343-4744 :.~ONMENTAL SERVICES DIVISI(~r REC Legal Description: Health Authority Approval Checkliat A. WELL DATA Well type ?hi{/A-'[~- If A, B, or C, attach ADEC letter. ADEC water system number ~'//~ Log present (~N) ~/ES Date completed Total depth ~-~0' Cased to /'~_p0tccr.- (~ ,,~ Casing height (above ground) Sanitary seal (~N) FROM WELL LOG Date of test Static water level Well production WATER SAMPLE RESULTS: g.p.m. Wires properly protected (~) AT INSPECTION + g.p.m. ~/= T~-~ Hou,;; Coliform (~ Nitrate ._~, ~'~C/n~-//._. Other bacteria O Date of sample: t P-) 0~ / c[°c Collected by: '~', B. SEPTIC/HOLDING TANK DATA Date installed ~>/Ol [ ~ Tank size 10(.)O ~CNumber of Compartments o~ Cleanouts(~N) Foundation cleanout (Y/I~ ~o Depression (Y/{~ ~o High water alarm (Y/~)) ~J/A Date of Pumping ~ Pumper C~/,-0 /~': DOt,~I-C~ C. ABSORPTION FIELD DATA ~ Date installed (~/Oj/::~ Soil rating (g.p.d./fF or/~n) System type ~EE~' '7'~¢H- Length ~O/ ,~,.,,c~a.~ .. ~,.,,, Width ?o41~ Gravel thickness below pipe ~v ~'Total depm Effemive absorption area ~0 ~F C~, Monitoring Tube pre~ent ~N) ~, Depression over field (YIN) Date of adequacy test I ~JO~ [~ Resul~ (Pass/Fail) ~%5 For T~ bedrooms F~uid depth in absorption f~e~d before test (in.); ~" ~mmediate¥ a~er~o=~, w=ter added On.): Fluid depth ~ ~ ~'' (ins) Minutes later: {~ ~. Absorption rate = ~0 ~ g.p.d. Peroxide treatment (past 12 months)(Y/~ ~o~ ~ If yes, give date 72-026 (Rev. 3/96)* Date i nstalle~e"d-~. ,..,~""'"'""--~ ~,, Size in gallon Manhole/Access (Y~)-'---.,.~~ "Pump off" level at* __ High water alarm level at* E. SEPARATION DISTANCES ~ SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot ! /~)O '/- On adjacent lots /OO --~ Absorption field on lot /~O ~- On adjacent lots /00 ~ Public sewer main Public sewer manhole/cleanout /tJ///~ Sewer/septic service line Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation,. ,.~,/~ ~.,~ ~"... i Property line /O '-/- Absorption field c:), Water, main/service.line /O Surface water/drainage /~O '-/- Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: i Property'line ID 4- Building foundation /O 1./- Water main/service line Surface water /00 '+ Driveway, parking/vehicle storage area Curtain drain ~'~Jo~ ~o~ Wells on adjacent lots R ENGINEER'S CERTIFICATION/A___ · · ~ :' I in conforma~'~' g~d'~es in'~ffect °n this *te. ' ~'~;' . " ~ ~',;~ ,, are Engineer's Name d~A' ~~ HAAFee $ '~ ''~ ~ ,, , Date of Payment Receipt Number ,Waiver Fee $ Date of Payment Receipt Number 72-026 (Rev, 3/96)* Alaska Water & Wastewater ?320 'East Chester Heights Circle -~ Anchorage ~ Alaska 99504 Phone (907) 337-6179 ~ Fax (907) 338-3246 Consulting Engineers December 14, 1997 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Subject: HAA for Private Well & Septic System. Lot 16, Bk 3, Conifer Heights S/D. To whom it may concern: The subject lot has a 3 bedroom house on it which is served by a private well and septic system. The results of the field investigation and adequacy tests are summarized as follows: A. WELL: The static water level on 12/4/97 was 233 feet below the top of the casing (BTC). Water was pumped from the well at a rate of 4.26 gpm for 75 minutes (320 gallons), during which time the level in the casing dropped 36 feet, to 269 feet BTC. At that time, it was noted that the flow rate was dropping off. In the following 238 minutes the flow rate averaged 1.24 gpm (295 gallons), and the level in the casing rose 26 feet, to 243 feet BTC. It was assumed that the reduction in the flow rate was due to the presence of a filter in the house which was clogging. Regardless, it is clear that the well production exceeds 1.24 gpm. In summary, over a period of 313 minutes the well produced 615 gallons, with a drawdown of only 10 feet, which corresponds to 1.96 gallons per minute. Based upon this data it was determined that the capacity of the well exceeds the Municipal requirements for a 3 bedroom house (.31 gallons per minute). B. SEPTIC TANK: The existing septic tank was installed on 6/1/78. According to the M.O.A records, it is 1000 gallons, has two compartments and is made of steel. Most tanks of this type have a structural life of approximately 20-25 years. No warrantee is made regarding the future life of the tank. C. SEPTIC SYSTEM ADEQUACY TEST: The trench is 40 feet long, 3 feet wide, and has an effective depth of 7 feet. Prior to starting the test the liquid level was 14 inches below the invert of the drainpipe. Six-hundred & fifteen (615) gallons of water was introduced into the sump over a period of 313 minutes, which caused the liquid level to rise 3 inches (11 inches below the invert). Twenty-four hours later the level had dropped 5.5 inches, indicating that greater than 615 gallons had been absorbed. Based upon this data, it was determined that the absorption rate of the trench exceeds 450 gallons per day, as required for a 3 bedroom house. NOTE: The adequacy of a septic system is influenced by numerous factors, including, but not limited to, seasonal surface water infiltration, groundwater variations, septic system maintenance (frequency of septic tank pumping, usage of biological additives), condition of drain pipe and pipe joints (which can be damaged by seismic activity and deteriorate with age), type of substances deposited in septic system (cigarette butts, sanitary napkins, misc. objects), and the amount of water being introduced on a continual basis. Consequently, the results of this adequacy test are only valid for the specific day of the test. Furthermore, because of the limited nature of this investigation, it is possible that there are hidden defects which may not have been detected. No warrantee is made regarding the future performance of this well or septic system D. DEPRESSION OVER TRENCH NEEDS TO BE FILLED: There is a visible depression near the clean-out at the beginning of the trench. This should be filled (spring 1998) prior to the issuance of a non-conditional HAA. E. CLOSING: If you have any questions, please contact me at 337-6179, or 244-9612. Thank you for your assistance. Je _~_y//A/~ess,'lLF-~, m. S. Princ~all ~ /0° 't ~ MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTIOf~IVIRONMENTAL PROTECTION ~~ ENVIRONMENTAL ENGiNEERiNG DiVisiONOCT ,RECEIVED ~EQUEST FO~ APP~OVAL OF INDIVIDUAL WATE~'AND 8EWE~ FA01LITIE5 DIREOTION~: Oomple~e ~11 p~r~s o~ p~ge ~. Incomplete re~u~ ~ill no, be pro~es~e~. Ple~e ~ltow ~en H0) ~Vs ~o~ pro~e~ing. MAILING ADD~ESS - PROPERTY RESIDENT {If'diffe~ent from above) - ~ / PHONE ~, BUYER - '_ ' ' ' - PHONE MA LNG ADDRESS 3, LENDING INSTITUTION MA LING ADDRESS ' ' --' ..... ' ........ 4, REALTOR/AGENT I PHONE' MAI LING ADDRESS I -- i F I Y [] One [] FOur [] Other I 1~- S NGLE AM L [] Two [] Five .I i--1. MULTIPLE FAMILY ~ Three I~ s,, I '7. WATERSUPPLY ' ' ' - I I ~ NDIV DUAL* *ATTACH WELLLOG Awel og srequredfora we sdr ed [] COMMUN TY since June 1975. For wells dri led p/rior to that date, give well - [] PUBLIC UT LITY depth (attach log if Brai,labia.) " 8. SEWAGE DISPOSAL SYSTEM - - ~ ~ - ~- INDIVIDUAL/ON-SITE** **If individual/on-site, give installation date If system is over two (2) years old an adequacy test is required [] PUBLIC UTIL TY by this Department. - ' NOTE: THE INsPECTIoN FEE MUST ACCOMPANY EACH REQUEST BEFORE PRocEsSING CAN BE INITIATED. 72-010(3/78) THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE [] SINGLE FAMILY [] MULTIPLE FAMILY 2. WATER SUPPLY [] INDIVIDUAL [] COMMUNITY [] PUBLIC UTILITY Connection Verified 3. SEWAGE DISPOSAL SYSTEM [] I NDIVI DUAL/ON -SITE [] PUBLIC UTI LITY Connection Verified []Septic Tank or [] Holding Tank Size: If Tank is homemade give dimensions: NUMBER OFBEDROOMS [] ONE [] THREE [] FIVE [] TWO [] FOUR [] SiX PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED PERMIT NUMBER DATE INSTALLED INSTALLER SOILS RATING TYPE OF TANK MANUFACTURER MATERIAL TOTAL ABSORPTION AREA 4, DISTANCES WELL TO: Septic/Holding Tank Absorption Area to nearest Lot Line Absorption Area JSewer Line [] OTHER INearest Lot Line 5. COMMENTS DATE LEGAL DESCRIPTION ~APPROV ED FOR ~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED 72-010 (Rev. 3/78) October 16, 1978 Samuel P. Star Rollte A Box 72-H Anchorage, Alaska 99507 SubJectl Lot 16 Block 3 Conifer Heights Subdivision This department has no records of a sewer system berg ins~alle~ on ~he sllbJeat property. A permit was not Therefore, your request for approval can not be granted until the following has been (1) Have a percolation test performed on the existing sewer system to determine its adequacy. (2) Supply this office with a receipt of the septic ~ank that was installed and also a receipt of gravel purchased for backfill. (3) Submit a ~ell log. (4) Obtain a permit from this office for ~he oons~t,aotion of a sewer system and ~he drilling of a well. (5) :~xpose five(S) feet of pipe l~to the inlet ~d {Ave(5) feet of pipe out of ~he outlet of the sel~cio tank. This is ~o verify the pipe~aterial used. there are ~y further questions, please ~ontact ma at 264-4720. Asso~iate Specialist Sta~e of Alaska Veteran's A~tministration 907 West No, hem Lights Blvd. 99503