Loading...
HomeMy WebLinkAboutCONTOUR ACRES #1 LT 1Contour Acres # 1 Lot 1 #017-451- 19 Municipality of Anchorage Development Services Department Building Safety Division 5 a On -Site Water and Wastewater Program, 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: 055 i0i 1113 13 PID Number: Oil - 45i - (I Name: �a OF c Wastewater System: ❑ New 'KUpgrade Address: 5� i ,4 f• P'l A AC6,r,x Q, ABSORPTION FIELD Phone: Number of Bedrooms: Deep Trench ❑Shallow Trench ❑Bed ❑Mound ❑Other: LEGAL DESCRIPTION Soil Rating: U: Total Depth from original grade: 12— GPD/Ft' Ft. Block: Lot: Subdivision: I Depth to pipe bottom from original grade: Gravel depth beneath pipe: �} Z:3 Ft. 1-1 Ft. Township: Range: Section: Fill added above original grade: r Gravel Length: 1 Ft. Ft. � Well: C,`f.t`ii�'1 ❑New ❑Upgrade Gravel width: Z, CJ Number of lines: Distance between lines: -- Ft. Ft. Classification (Private, At, C): Total Depth: Ft. Cased to: Ft. Total absorption area: ( 1 � ` Ft' Pipe Material: ru) 4 S,� 40 Driller: Date Drilled: Static Water Level: Installer: `S � 3. Date Instaalllle : p Q Ft. W 14t I ! tZoj o Yield: Pump Set at: Casing Height Above Ground: TANK GPM Ft. Ft. SEPARATION DISTANCES ❑ septic ❑ Holding S.T.E.P. ❑ Other: To From Septic Tank Absorption Field Lift Station Holding Tank ublic/Private Sewer Line Manufacturer: /� "Inc ko Capacity: Gal. ,;, e an Well A/� t V®, �" ii �V���1 IK. f 1 i L� t NIA r ' ZO .T Material: c}} S 94 Number of Compartments: Surface Water �1�Q`t � `� A•A LIFT STATION Lot Line , .} , .�. S ..+ a y J/..�� Size: I 6co Gal. Manufacturer. ,--� Foundation .+. N A "Pump on" level at: r S in. "Pump off' level at: _Z n. High water alarm at: ! 4 in. Curtain Drain c 50-t c v + s u AV Pump Make & Model UfLQvICi� Electrical Inspections performed by: ��lA A��, t Remarks: FILI ANS BENCH MARK ` �n �► F � � �e Location and Description: 3vl Sit, C Of a , 64 C,-, Assumed Elevation: ON see,, Ft. � L a,� SP " 2C► -U Engineer's Stamp Inspections performed by: -�-c� Dates: 1St 1 2nd q ybori0 , t --- � O F A.Cq 1l Development Services Department Approval.. .arc. ° t5+�� jr Conditional Approval Date: 9 TH f� '-%%�� , r00 S E(SPUn,•CLAND. Reviewed and approved b ^ `'/' �% f�' Date:)Ij3 1 (Rev. 04/06) PFE HUFFMAN ROAD I ,H RIDIG INSULATION UA WAY SECTION )ONED EXISTING SEPTIC PER UPC REQUIREMENTS 1500 GALLON STEP F LEVEL LEVEL INSTALLED 4 -BEDROOM SEPTIC 1500 GALLON STEP TANK ® LEVE G LENGTH 68 FEET WIDTH 2.5 FEET TOTAL DEPTH 12 FEET ROCK DEPTH 9.7 FEET 2 INCH INSULATION COVER 3.0 1 FEET Lot 24 B SWING TIES C 4.0'69.5 ' D 47.0' 71.5' E 52.0' 73.0' F 13.0'120.0 18.0'99.5'G Lot 1 S I� Well 1 OS OF �P G� 00 0 1NOTE. THIS IS NOT A SURVEYED PLAT. WELL & SEPTIC LOCATIONS TAKEN FROM ON-SITE WATER AND WASTE WATER %L •••• •; APPROXIMATE.DEPARTMENT D000MENTATION. ALL LOCATIONS SHOWN ARE %::..F:••••••/••�* •••^� 0��RKLAND ;'� V AV ♦� �::.. NO, CE -11500 :��ti=/ illillim 25 0 25 50 75 100 125 150 ♦• ����� ww�����••• SCALE 1' = 50 FT SPURKLAND ENGINEERING CONTOUR ACRES 1 LOT I SEPTIC SYSTEM ASBUILT 203 W 15TH. AVENUE JUDY TOPE DA TE. SEPT. 20, 2010 ANCH. AK. 99501 5700 HUFFMAN ROAD, ANCHORAGE, AK 99516 SHEET • 1/3 GRID: 2837 907 279-3916 PERMIT #OSP101148 PID # 017-451-19 CONTOURACRES#ILIDI PRIMARY TRENCH N, TS STANDARD DEEP TRENCH., Test Hole R E.G. Elev.=99.4 Ele Sil t Bar 2,5' Wide 68' Long 12' Deep 9,7' Sewer Rock 2 Inch Insulation installed over drain field 3' Cover NO SCALE I Elev.=87.6' 9,7 Ft of Septic Rock 1500 CAL STEP TANK B.O.H. Elev.=81.4' NO SCALE BENCH MARK BOTTOM SIDING ®"A" ON SITE PLAN ASSUMED ELEVATION 100 FEET SPURKLAND ENGINEERING CONTOUR ACRES #1 LOT 1 SEPTIC SYSTEM ASBUILT 203 W15th Ave JUDY TOPE DATE: SEPT. 20, P010 Anchorage Ak 99501 ?79-q91A 5700 HUFFMAN ROAD SHEET: 3/3 GRID: 2837 PERMIT # OSP 101148 PARCEL ID # 017-451-19 CONTOURACRES11 L 1 D 1 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP101148 Tax Code Number: 01745119000 Work Type: Septic Upgrade Permit Effective Dates: August 25, 2010 to August 25, 2011 Design Engineer: SPURKLAND ENGINEERING Subdivision: CONTOUR ACRES #1 Site Legal Address: CONTOUR ACRES #1 LT 1 G:2837 Owner/Address: TOPE ROBERT & JUDITH LIV TRUST 1120 E HUFFMAN ROAD #212 ANCHORAGE AK 995153512 Site Mailing Address: 5700 HUFFMAN RD, Anchorage Lot Size in Sq Ft: 84460 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage /0,1 , All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By Date: i Municipality of Anchorage 0 A -W Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, Alaska 99507 www.muni.org/onsite (907) 34377904 ON-SITE SEWER/WELL PERMIT APPLICATION _ FOR A SINGLE FAMILY DWELLING Parcel I.D. _ 01-4— 451 i I Property owner(s) Jealy I ope-I //II Day phone 3 M 5 _ -15 ?0 Mailing address_ G_�Zo Ar(,Ii( l��uc . AnAo�� e A< Zip Code `i t5) 8 Site address 51ot: Zip Code 1 1 5t to Legal description (Sub'd., Block & Lot) C0111�0%44_ A c,5 -,"I Loi 1 Legal description (Township, Range & Section) Lot Size Sq. Ft THIS APPLICATION IS FOR (® all that apply): Absorption Field Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms y THIS APPLICATION IS AN: Initial ❑ Upgrade Renewal ❑ certify that the above information is correct. I further certify that this application is being made for a in ,jgle Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Waiver Fees: Date of Payment: ` (' F . Date of Payment: Receipt Number: C-v�'r Receipt Number: (Rev. 11/05) SpHft�@Jnd g Environmental Consulting and Design SEPTIC SYSTEM DESIGN Contour Acres #1 Lot 1 Municipality of Anchorage August 6th, 2010 Development Services Department On Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, Alaska 99519 Subject: Septic System Installation Permit 5700 Huffman Road Ladies and Gentlemen: I am writing to request a permit to upgrade the septic system for the above referenced property. The proposed system will serve a 4 -bedroom single-family residence. The existing system is over 34 years old and no longer meets house hold needs. Soil logs, design calculations, a site plan, design drawings and construction specifications are enclosed for your review. Design Calcs: No Groundwater observed to a depth of 20 feet below ground surface (8/6/2010) Soil Rating: From Testhole 7/30/2010 30 min/in = 0.6 gal per sq.ft/day (TH#I) 12.6 min/in = 0.8 gal per sq.ft/day (TH#2) No. of Bedrooms 4 Required Area per Bedroom: 15010.6 =250 sq,ft. Minimum area required: 250 x 4 = 1000 sq,ft. System: We are proposing a 1500 gallon STEP tank, and a deep trench absorption field. The absorption field will be 60 feet long and 2.5 feet wide with 9 feet (1080 sq.ft. effective) of sewer rock. Soils: Two test holes were excavated on July 30, 2010. Seethe attached soil logs. Silty soils were observed. Ground water was monitored for through August 6th, 2010. Ground water was not observed. A percolation tests was conducted at 4.5 feet below grade by each test hole. Surface Water: There are no surface waters within one hundred feet of the proposed septic 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci.net SPUTMalmd EIMU�'[Msm'�'[Ma Environmental Consulting and Design system upgrade. Topography: The area of the proposed septic system upgrade in generally level Waivers: No waivers required. The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. If you have any questions or concerns, please contact me at 279-3916. Sincerely, L11115 ;r� Lars Spurkland, P.E. Civil Engineer 203 West 151h Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci.net HUFFMAN ROAD — — — — — F- — — — — — — — — — — — — — — � I Q weal I In�I Lot 2A I ll I I � l — — — — l z I I I �to Lot 1 i b I I wen I I I II Lot 2B I I I I� I C p I Lot 3 I �.•••� OF q �•• • NOTE. THIS IS NOT A SURVEYED PLAT. WELL & SEPTIC A LOCATIONS TAKEN FROM ON—SITE WATER AND WASTE WATER 49th DEPARTMENT DOCUMENTATION. ALL LOCATIONS SHOWN ARE... ••• APPROXIMATE. % �. .............. : . 4SL S SPURKLAND 1♦✓J,�:,,.. No.,C:-11500 Q Q: AV ♦c AV 50 0 50 100 150 200 250 300 ♦• F1I P b'• •' •" P�' �� SCALE 1' = 100 FT ••. ROFESSZ��• SPURKLANU ENGINEERING CONTOUR ACRES I LOT 1 SEPTIC SYSTEM DESIGN 203 W 15TH. AVENUE JUDY TOPE DATE.- AUGUST 4, 2010 ANCH. AK. 99501 5700 HUFFMAN ROAD, ANCHORAGE, AK 99516 SHEET. 1/3 GRID: 2837 907 279-3916 PERMIT #SW080XXX PID # 017-451-19 CONTOURACRES#ILIDI HUFFMAN ROAD I— 12 -INCH R/DIG INSULATION UNDER RIVE WAY SECTION INSTALL DEEP BURIAL TANK (10) 1500 GALLON STEP Well LEVEL ® INSTALL 4 -BEDROOM SEPTIC SYSTEM 1500 GALLON STEP TANK LENGTH 60 FEET WIDTH 2.5 FEET TOTAL DEPTH 12 FEET ROCK DEPTH 9 FEET COVER 3.0 FEET Lot 2A Lot 1 /S NOT A SURVEYED PLAT. WELL & SEPTIC TAKEN FROM ON-SITE WATER AND WASTE WATER r DOCUMENTATION. ALL LOCATIONS SHOWN ARE IS►� �1 OS �P c� 00 0� 51 50 75 'S�/t7 F�llv 25 0 25 SCALE' 1' - T, 100 125 150 �1 kS ; 50 F SPURKLAND ENGINEERING CONTOUR ACRES 1 LOT 1 SEPTIC SYSTEM DESIGN 203 W 157H. AVENUE JUDY TOPE DATE: AUGUST 4, 2010 ANCH. AK. 99501 5700 HUFFMAN ROAD, ANCHORAGE, AK 99516 SHEET • 3 GRID: 2837 907 279-3916 PERMIT #S6108OXXX PID # 017-451-19 CONTOURACRES#ILIDI PRIMARY TRENCH N. TS STANDARD DEEP TRENCH., 2,5' Wide 60' L ong 12' Deep 9' Sewer Rock 3' Co ver Silt Barrie NO SCALE 1500 GAL STEP TANK RATED FOR A BURIAL DEPTH OF 10' 9 Ft of Septic Rock Effective 1500 GAL STEP TANK SPURKLAND ENGINEERING CONTOUR ACRES #1 LOT I SEPTIC SYSTEM DESIGN 203 W15th Ave Anchorage Ak 99501 JUDY TOPE DATE: AUGUST 6, 2010 ?79_Z91r, 5700 HUFFMAN ROAD SHEETi 3/3 GRID: 2837 PERMIT # PARCEL ID # 017-451-19 CONTOURACRES# 1 L 1 D 1 I Municipality of Anchorage -� Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci.anchorage.ak.us (907)343-7904 Soils Log - Percolation Test o 49TH �'. LARS E.+SPURKLAND:6c, / Aa k Performed For: j ,ply )pin„ Date Performed: A Legal Description: cc'l Vii.Ar res a I L , t Township, Range, Section: 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- vs.o. ". b WAS GROUND WATER Date Gross Time ENCOUNTERED? Xj Net Drop S IF YES, AT WHAT DEPTH? 11 " L Depth to Water After 0P Monitoring? E Date: 3, 6'i Site Plan Reading Date Gross Time Net Time Depth to Water Net Drop Z.o� 0 r' ;n 11 " it, 3, 6'i ' I r r PERCOLATION RATE 30 (minutes/inch) PERC HOLE DIAMETER (1 TEST RUN BETWEEN .5 FT AND 5; 5 FT COMMENTS p`Z 1) _ PERFORMED BY: LAR, 14pL4rW i�v\s I :Ns y�Llr(� �—' CERTIFY THAT THIS TEST,WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELI ES IN EFFECT ON THIS DATE. DATE: -7 Lli li Municipality of Anchorage .� �; �S, Development Services Department Building Safety Division "�x'� On -Site Water and Wastewater Program X491H _ <�.': 4700 Elmore Road ..... P.O. Box 196650 Anchorage, AK 99507 www:ci.anchorage.ak.us • LABSSRURKLAND : v (907) 343-7904 Soils Log - Percolation Test Performed For: ��y but Date Performed:tL Legal Description: Cor,4o,c- Ac,; -e,' 4LI Lo+ Township, Range, Section: 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- 1L J WAS GROUND WATER ^ /J Gross Time ENCOUNTERED? 4 Net Drop S IF YES, AT WHAT DEPTH? — L Depth to Water After �� P P Monitoring? 4{ 1r�y 'Y E Date: r%It7 3.V. Site Plan Reading Date Gross Time Net Time Depth to Water Net Drop =�/', �� L`J T �rY► ..//J0�� s'"!iN 4{ 1r�y 'Y •") cJ'/ is 1r 3.V. }ray' tI 3' 34 PERCOLATION RATE 17— 6 (minutes/inch) PERC HOLE DIAMETER (� TEST RUN BETWEEN<f, Cj FT AND 5� FT COMMENTS �'+: S�z jj<j PERFORMED BY: L_AC5 `�� 144 Oki I Gt jy So cv, L r CERTIFY THAT THIS TEST WAS O PERFORMED IN ACCRDANCE ITH ALL STATE AND MUNICIPAL GUIDELIN _3 S IN EFFECT ON THIS DATE. DATE: 2c i • ■ a "" F �J O l..;il � LJ U� l�.l LI LI l:�.l � LJ LI 0 � LJ LI �J �J � � LJ LJ O a g g Environmental Consulting and Design 00 Single Family On-site Wastewater Disposal System Construction and Material Specifications Subject Property: Contour Acres #1 L1 Date: August 6th, 2010 General: 1. The owner shall contract with a contractor to perform the work outlined in these specifications and plans in accordance with the attached MOA permit. There is not contractual arrangement between the contractor and the Engineer. The Engineer shall be the owner's representative and will inspect the work to document the contractors activities. Final acceptance of the contractors work rests with the owner and the MOA. 2. The scope of the project includes the procurement and installation of a 4 -bedroom on- site wastewater disposal system at the location depicted on the attached site plan drawings. The scope of the work also includes the installation of a new 1500 gallon STEP tank, a drain field comprised of 1 trench, 2.5 -feet wide x 60 -feet long, 12 feet deep, with 9 feet of septic rock below the distribution piping. All components of the proposed septic system must be constructed a minimum of 100 feet from any surface water or water wells in the area. A minimum of 4 feet of earthen cover is required over the septic tank and a minimum of two feet of cover is required over the drain field. If there is less than 3 feet of earthen cover, 2 -inch thick, 40 psi, direct bury board foam shall be installed directly over all installed piping. 3. Construction shall be in accordance with the approved site plan and design drawings and any special provisions noted on the Municipal well and/or septic permit. All materials, components, workmanship and construction practices shall comply with the Municipality of Anchorage's latest ordinances regarding wells and septic systems, as well as MOA, Development Services Department, On-site Water and Wastewater Program (DSD) policies. 4. The contractor is responsible for obtaining all underground utility locates, layout of the proposed system, and verifying and maintaining all required separation distances to lot lines, surface water, wells, steep slopes, etc. S. The property owner shall be responsible for final grading any depressions formed from settlement of backfill material. The property owner is also responsible for vegetation of all areas disturbed by septic system installation activities. 6. Contractors installing wastewater disposal systems must be certified to do so by the MOA DSD, On-site Water Wastewater Program. Property owners installing their own systems must receive advanced approval from MOA DSD prior to system installation activities. 7. The contractor shall ensure that ALL materials being used are in compliance with the most current guidelines established by the Municipality of Anchorage. Refer to "Standards and Specifications for Component Parts and Materials Used in the Construction of On-site Wastewater Disposal Systems", Dated December 2000, as provided by MOA DSD, On-site Water and Wastewater Program. 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci.net .h a g g Environmental Consulting and Design Septic Tank Installation: 1. A new septic tank, of the size specified in the design drawings, shall be procured from a qualified manufacture/supplier if the existing septic tank is found to be defective. Construction shall include two 4" diameter cleanouts for pumping access. 2. The burial rating of the tank shall be adequate for the actual burial depth encountered. 3. The tank shall be level and sufficiently bedded to prevent settling of shifting of the tank. 4. All standpipes on the tank shall extend a minimum of 12inches above the final grade. S. Tanks installed with less than 4 feet of cover shall be insulated. 6. The sewer service line from the house to the tank shall have a minimum slope of 2% unless prior approval is obtained from the engineer. 7. The inlet and outlet lines from the tank shall be bedded in drain rock or the soil shall be sufficiently compacted to prevent future settlement of the soil. 8. Septic tank inlets, outlets and cleanouts shall be fitted with water tight couplings. 9. A cleanout shall be installed 1 to 4 feet from the foundation. 10. Post tank cleanouts shall be installed per MOA requirements. Does not apply to pressurized lines. 11. In areas with high ground water, the septic tank shall be sufficiently anchored to resist buoyancy forces when there is not adequate soil cover to resist uplift force. The contractor shall refer to the engineer for direction regarding this matter. 12. The tank backfill shall be graded sufficiently to ensure positive drainage away from the tank. 13. All holding tank and lift stations shall have an audible and visible alarm inside the residence being served. 14. All lift stations shall be wired in compliance with all MOA guidelines and the Uniform Electrical Code. A municipal electrical permit and inspections must be obtained where required by the MOA. 15. The contractor shall verify that the septic tank/lift station is a minimum of 100 feet from any residential water well, 150' from any class 'C' well and 200 feet from any community water wells. Additional separation distances must also be maintained. 16. The contractor shall remove or abandon the existing tank in compliance with the Uniform Plumbing Code. Drain field Construction: 1. The drain field shall be excavated to the dimensions outlined in the design drawings. If any discrepancies are noted, contact the engineer immediately for clarification. 2. The drain field shall be installed parallel to slope contours. 3. The bottom of the drain field shall be within 2" of level. If the sidewalls or bottom of the excavation become smeared, they must be raked or scarified prior to the placement of filter sand or drain rock. 4. The drain field must be a minimum of 5 feet from the test hole excavation. 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci.net a g g Environmental Consulting and Design S. Distribution pipe is to be installed level with perforations facing downward, atop a level bed of drain field rock. Septic rock shall then be placed atop the distribution piping to provide a minimum of 2" of cover, level across the entire width and length of the trench, above the piping. 6. A silt barrier must be installed at between the final drain rock and the native soil backfill. The silt barrier shall cover the entire drain rock surface. 7. Monitor tubes must be 4" in diameter, installed in the locations depicted on the design drawings, and extend a minimum of 12" above final grade. The portion of the monitoring tube below the septic rock must be perforated and the portion above the drain rock shall be solid. S. Backfill over the final gravel layer must not be less than 2 feet. Insulation must be installed when the backfill depth is less than 3 feet. 9. Drain field back fill shall be mounded to prevent depressions from forming due to subsequent settlement of backfill material. 10. The contractor shall verify that the drain field is a minimum of 100 feet from any residential water well, 150' from any class'C' well and 200 feet from any community water wells. Additional separation distances must also be maintained. Inspections: 1. A minimum of two inspections are required by the Municipality of Anchorage. These inspections must be conducted under the supervision of a Professional Engineer licensed to practice in the State of Alaska. 2. The first inspection must be conducted after the excavation of the drain field and before the placement of any gravel. The septic tank may be set in place, but may not be backfilled. 3. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, stand pipes, cleanouts, and insulation, but before the placement of any backfill. 4. The contractor shall provide a legible copy of all field notes relating to system layout and construction to the engineer for the use in preparing the record drawings. S. The contractor shall coordinate all inspections with the Engineer. A minimum of 24 hours notice is required prior to the start of construction. If necessary, a preconstruction meeting will be held on-site. 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci.net NAME LOCATION SEPTIC TANK: r°Ww GRE; , CR ANCHORAGE AREA BOR, _:GH Department of Environmental Quality �,.ro• 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM MAILING ADDRESS E LEGAL DESCRIPTION �9Sd % 4�/ C,0=.7,� DISTANCE��,,� NUMBER OF FROM WELL/L- MANUFACTURER MATERIAL COMPARTMENTS INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY1 GALLONS. TILE DRAIN FIELD: TOTAL LENGTH DISTANCE FROM WELL/1%y t FOUNDATION Zo fi NEAREST LOT LINE a OF LINES 4��91 NUMBER OF LINES DISTANCE BETWEEN LINES TRENCH WIDTH13� IN. TOTAL EFFECTIVE j 7 ABSORPTION AREA SQ. FT. LENGTH OF EACH LINE L� DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE MATERIAL BENEATH TILE -6 -*V ABOVE TILE __,:eIN. WELL: TYPE I CONSTRUCTION DEPTH - BUILDING NEAREST NEAREST SEPTIC SEEPAGE FOUNDATION , LOT LINE , SEWER LINE , TANK , SYSTEM_ CESSPOOL APPROVED DISTANCES: INSTALLED BY: OTHER SOURCES DISAPPROVED 1 SEWER LINE DEPTH: y PIPE MATERIAL: LOT SLOPE: ► - REMARKS: 0,200 Form EQ -032 REMARKS DISTANCE FROM: DATE -10-4 APPROVED ������������ym CA F17 F"U 14 CD VJ "I F;;,.,!: 0::::::o C�� P/Y DEPARTMENT HEALTH AND ENVIRONMENTAL <OTECTION 2516 E. TUDOR RD., ANCHORAGE, HK 9>507 _ 276-2221 /J��' C0140_5 1 _T� ������ _ ���� � �' �u�, � � r � °� PERMIT NO. ( 76682 ) m��. HPPLICHNT SRH BOX 1685 ]44-972] LOCATION HUFFMHN ROAD LEGHL L1 B1 CONTOUR ACRE-'*.*; LOT SIZE 84460 SQUARE FEET TYPE OF SOIL HBSORBTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS = 4 SOIL RATING (SQ FT/BR)= 200 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: A.22 lL.EEp4c3-rwi= mEl illEE101-T-1-i= 7" THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRHINFIELD. THE DEPTH OF H TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). lot K (To k -A 1 1 IC-:: F- F:1 r4 15 Ca ������S,�­ , .0 22 :0 !K FA Eli. 1: CA 44 S3 FT FZ EE ��8.7;:� L.1 l: FR�� BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN H WELL AND ANY ON-SITE SEWAGE 100 FEE/ FOR DISPOSAL SYSTEM IS M PRIVATE WELL OR 200 FEET FOR H PUBLIC WELL SINSTALLATION.PECIFICATIONS AND CONSTRUCTION DIAGRAMS HREHYHILHBLE TO INSURE PROPER F=" FEE Q twl 1 -1� �EEFI�� ���� ����E 1 CERTIFY THAT �� 1� I HMyFTHEHMILIHRIWITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET -^ �I�� ,� INSTALL THE S�T- '"""nunnu�� UNDERSTAND THA'' TH�O�y1IN ACCORDANCE WITH THE CODES ��5IDENCE IS REMODELED cO m-CS1TEESEWER SYSTEM MHY REQUIRE ENLHRGEMENT [MHN 4 BEDROOMS. IF THE MORE�1������� �11 V..^~~~-...-.~��Z�___- ___________ ANCHORAGE FAIRBANKS CONSULTANTS, INC. JUNEAU 249 EAST S1ST AVENUE • P.O. BOX 8087 . ANCHORAGE. ALASKA 99303 • TFLEPHONE 907-279.0483 • TELPX 09033419 June 1, 1976 R & M No. 656244 Mr. Joe Fabin 2440 Tasha Drive Anchorage, Alaska 99502 RE: Test Hole and Soil Log Report for Sanitary System Lot 1 Block 1 Contour Acres Dear Mr. Fabin: We are submitting herewith the boring logs, percolation results and our comments regarding soil conditions encountered at the subject site. This investigation was performed in accordance with your request of May 14, 1976, and those procedures outlined in a letter dated July 15, 1975, by Mr. Rolf Strickland of the Municipality:.of Anchorage, Department of Environmental Quality... A single test hole was put down within the Lot 1 area for the purpose of defining general subsurface soil conditions and conducting percolation tests for the proposed sanitary system. Excavation was accomplished with a tractor mounted auger type drilling rig and the test hole was extended to a total depth of 20.0 feet below ground surface. The final log was prepared for the test hole and has been included in Drawing A-01. Ground water was not encountered in the test hole. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M CONSULTANTS, INC. James W. Rooney(AQ Vice President �4 / JWR/PJ/pe xc: Municipality of Anchorage PERCOLATION TEST JOE FABIN R & M NO. 656244 ELAPSED DROP TIME TIME INCHES 1:30 0 Q 1:31 1 3 1:32 1 1 1/2 1:33 1 1 1:34 1 .1/2 1:35 1 1/2 1:40 5 2 1:45 5 1 3/4 1:50 5 1 1/2 1:55 5 1 1/4 -2:0@ 5 _ 1 2:05 5 2:10 5 3/4 2:15 5 1/2 2:20 5 1/2✓;`# 2:25 5 1/4 2:30 5 1/2 60 Minutes 17.5 Total Drop 7 ,,P:i Mir1 i f g j 9\ ._N TH 1 VRZ%e 5-28-76 0.0' SANDY SILT (ML) 0.51 CKD- p v SILTY SAND W/TRACE .1 GRID= GRAVEL (SM) 6-1-7 ---- ------- 3.0' �_ Fabin . . PROD.y0. 6_56g44 SCALE= 1+._3. p & M C004SUL.TANTS,1Nc. Anchorage, -''Alaska SANDY SILTY `�$ GRAVEL (GM) -------------- 5.0' SILTY SAND W/SOME GRAVEL (SM) -------------- 10.0' SANDY SILT - SILTY SAND W/ SOME GRAVEL (SM -ML) (260) _----__------- 13.5' SANDY SILT (NII,) — .- -- — -- —.— — 15.5' SANDY SILT - SILTY SAND (SM -ML) (260) No Water Table 20.0' TD DWI* VRZ%e F.B. CKD- p v Log of Test Hole _ `Joe GRID= DATE= 6-1-7 � ^ Fabin . . PROD.y0. 6_56g44 SCALE= 1+._3. p & M C004SUL.TANTS,1Nc. Anchorage, -''Alaska OWG.NO. A-01 V ,4U1c'<<!t4AN 80,40 h SB 9' S 9' E �OG_04 i I I � � I ' a i 10 1 rAc_ rtL 9 _ti< <,i 11.11 MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION SEF -2 21 1� LE RECEIVED SQA, 1 ,vd9'S9'rN ?o6. oo' I »ERE.Y CERTIFY THAT AN ACCURATE SURVEY Of TME FOLLOWING 093011610 PROPERTY LOT 1 ! CONTOUR ACRS S, ADD. N01 r.EPMEO DVA: WAS WAGE /J X977 ANO THAT TME Ir• i >'tiIOVKII1KNTi SITUATED rM1REOM AAK WITHIN THK PII(I- ERTr LINKS ANG 00 MDT OVERLAP ON ENCROACH ON TME _ti< <,i 11.11 MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION SEF -2 21 1� LE RECEIVED SQA, 1 ,vd9'S9'rN ?o6. oo' I »ERE.Y CERTIFY THAT AN ACCURATE SURVEY Of TME FOLLOWING 093011610 PROPERTY LOT 1 ! CONTOUR ACRS S, ADD. N01 r.EPMEO DVA: WAS WAGE /J X977 ANO THAT TME Ir• >'tiIOVKII1KNTi SITUATED rM1REOM AAK WITHIN THK PII(I- ERTr LINKS ANG 00 MDT OVERLAP ON ENCROACH ON TME P!O/ERTY LTINO AOJACENT rMERETG,THAT 40lWeIOVEYENT V �� BUILT ]I n10KRTr LTtNK ADJACENT rm"gTv ENCROAOI Ow T 'IL ^u VO' ;9- a P+trISKS N zu1ST$0W ANG T)4AT rHERE UK ■O ROAD 'IG1119S10N 0418 00 OTHER .Iflsu 'J►ultNri ZA ',A'0 +'WiYiRfT ct�ifr iW 1-,�7#. '_!7 a , .-...�-� .ase _ .,,., .....i „.- •a:f. a�. '�' a� J.' MUNICIPALITY OF ANCHORAGE I N G DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION 2820 'C' Street, Suite #3 Anchorage; Alaska 99503 U IV 2 ,':276-4855 RECEIVED June 1, 1981 Joseph Fabian NHN Huffman Anchorage, Alaska 99507 Re: Adequacy Test of Septic System Lot 1 Block 1 Contour Acres - File Number 81-E-22 Dear Mr. Fabian: As per your request, I have completed the adequacy test on the above lot in accordance with the Municipality of Anchorage recommended standard procedure. The system consists of a septic tank and approximately 72 linear feet of drainfield. Water had to be trucked in to provide the required 10 gallons/minute supply for a total of 600 gallons, as required for a four bedroom home. The water was added directly to the septic tank and was monitored at 100 gallon increments. The test results were tabu- lated for both days of the test as shown on the attached sheet. The results indicate that the system recovered a little slow after the first day's test at the far end of the field, but returned to the ini- tial level shortly after completion of the second day's test. At no time during the test did water back up to the start of the drainfield or present any indication that it would back up into the tank and the drainfield system appears to be functioning adequately at this time. Sincerely, Wayne enderson WH:zc-p Enclosure PENINSULA ENGINEERING AD ;QUACY TEST M i en t : Joe Fabian Ad(Iress: Huffman and Birch Legal: Lot 1 Block 1 Contour Acres Subdivision System: Septic Tank with Drainfield (approximately 72 L.F.) 1)F1''1'Il� - 111?I''I'11� J1'I'I;lt DDF t ( . -� ep DATE TlAE(ill,n) 51�.1':I_LC 'TANK 51" :il',I:I'ACI. Pi.'I' 0 ( Lm) PATI_ AUDI -.0 (gill) End Trench 5/28 0 0 0 63" 1981 0 Start test 51" 0 10 0 63" 5 min 10 min 52" 0 10 100 65" 15 min 20 min 53" 0 10 200 65" 25 min 30 54" 0 10 300 67" min 35 min 40 54" 0 10 400 68" min 50 min 54" 0 10 500 68" 80 min 54" 0 10 600 68" 5/29 ;1 min 51" 0 10 0 65" 1981 min 10 min 51" 0 10 100 67" • A, min •°°•°`,0 A. 20 milt 52" 0 10 200 68" • s 4� mill '• ••• •°...I 3 Millf0 0000 o min 54" 0 10 300 69" 00000 HENDERSON 4488 . ° ,? go 1+ 54 0 10 400 70" �.° � m in .o••o° 9 ® 0 50[ 54" 0 10 500 - .. SS�Qitis ��` min 70" ®®® 60 nl in 54" 0 10 600 70" 5/29 65 min 52" 0 0 600 65" WATER WELL RECORD STATE OF ALASKA DEPARTMENT OF NATURAL RESOURES Division of Geological a Geophysical Surveys Drilling Permit No. LOCATION OF WELL (Please complete either la, ib or Ic.) A.D.L. No. lo. Borough Subdivision Lot Block Ib. 1 1/4gtrs. Section No. Township N❑ Range E[3Meridian F1Gr1.—Of —of—of _. S❑ W Ic. DISTANCE AND DIRECTION FROM ROAD INTERSECTIONS 3. OWNER OF WELL: Address: BOl sOTC Lot 1 PL:. 1 Street Address and Area of Well Location Cmtoa low— u 1 2. WELL LOG Fest Below Surface 4, WELL DEPTH: (final) 5. DATE OF COMPLETION _ t' a`7� Material Type Top Bottom drilled 1 ''CIC): 6, Ej Cable tool ❑ Rotary ❑ Driven ❑ Dug ❑ Auger ❑ Jetted ❑ Bored ❑ Other S+f Lt'. 11 0 L r '1 ;<1 ,' i -•. 4q, 66 ?.USE: ® Domestic ❑ Public Supply ❑ Industry ❑ Irrigation ❑ Recharge ❑ Commerical Test Well ❑ Other: Nr:7�t? tlf.� 7S to 121 1� r' S. CASING: ❑ Threaded [] Welded diore.ft in. to) 79, ft. Depth Weight A` Ibs./ft. diom, in, to ft. Depth Stickup ft. 17= 1J: 15= DrJ_].ILT b OC: I4.'• 1531-61, 9. FINISH OF WELL: Type: C 1 IY,tt'cT_ Diam*to r•_ 161 t ; s - ,-:aqs> • ?;t_r :V 1;99'ar S.L,.?.itO.b. �;.^ 1� Slot/Mesh Site: Length: Set between ft. and ft. Backfilling Grovel pack G_ar,' C.1,4y [r1Xa?• with tCIV.rr,-1VEl. Z' 172 7"R 7C' 17, 1: 10. STATIC WATER LEVEL: .; ft. I ir- F.. , ) scaC.rce h:i: ?liL`d-)L!, i0"t �tE3t kJ'� i.. Date ❑ Above a 0 Below land surface Equipment used: dam v -d1 i I I. PUMPING LEVEL below land surface and YIELD 170 ft. after I Ars, pumping 7 g.p.m. ft. after hrs. pumping g.p.m. 12.GROUTING Well Grouted: ❑ Yes ❑ No Material: ❑ Neat Cement ❑ Other: NCI 1C?vd l"l.N VV^dC�rI�N3 () lodQ 30Vd0H" 13. PUMP: (If available) HP Length of Drop Pipeft. ft. capacity g.p.m. ® Subm. ❑ Jet ❑ Centrifical ❑ Other 14. REMARKS: '1..i't r f:.TkdEs r, fixe] 170' 1 16. WATER WELL CONTRACTORS CERTIFICATION: 15. Water Temperature ° ❑ F ❑ C This well was drilled under my jurisdiction and this report is true to the best of my knowledge and belief; UUtwi #.11,ing %0. AACJ512 Registered Business Name Contract License Number Address: ^' c Signed : Date: Authorized Representative Form 02-WWR (11/81) Copy Distribution: WHITE -State 0908, PINK -Driller, CANARY -Customer • Municipality of Anchorage On -Site Water and Wastewater Program (907)343-7904 s. Certificate of On -Site Systems Approval ^� Parcel I.D. 017-451-19 Expiration Date: 1 1. GENERAL INFORMATION Complete legal description Contour Acres #1 Lot 1 Location (site address) 5700 Huffman Road, Anchorage, AK 99516 Current Property owner(s) Judy Tope Day phone 345-7580 Mailing address 5700 Huffman Road, Anchorage, AK 99516 Real Estate Agent Dave Weir Day phone 529-9347 2. TYPE OF DWELLING: Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY Individual Well Ej Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ WaiverNariance request for: Received by, TYPE OF WASTEWATER DISPOSAL: Individual x❑ Holding Tank ❑ Community ❑ Public Sewer ❑ COSA to be rete ed ,the engineer, unless othenvise requested by the engineer. Date: OI COSA Fee $ 1�21z? 00 Waiver Fee $ Date of Payment I �� Date of Payment Receipt Number DRD��D Receipt Number COSA #S� CL Ila lqg Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm C & M Engineering Address 30840 Prudhoe Bay Ave Eagle River, AK99577 Engineer's Printed Name Charles Balzarini 6. DSD SIGNATURE System #1 Approved for _�_ bedrooms System #2 Approved for bedrooms Disapproved Phone 907-854-5558 Date 10/�/4 sit 9 6 . . llf, t, CHARLES G BALZARINt Yp��t�.9F0 p CE-13854 Conditional approval for bedrooms, with the following BOriginal Certificate Date: /b K D ti The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet f . : c If more than 1 septic system is on the lot: COSA Checklist # 1 of Structure served by this system •1` Certifi.cate,of On -Site Systems Approval Checklist Legal Description: Contour Acres #1 Lot 1 Parcel ID: 017-45.1-19 A. WELL DATA i Well type Private If A, B, or C provide PWSID # Well Log (Y/N) Yes Date completed 3/7/1983 Sanitary seal (Y/N) YeS Wires properly protected (Y/N)YeS Total depth 300 ft. Cased to 180 ft. Casing height (above ground) 24 in. , FROM WELL LOG AT INSPECTION Date of test 4/1/1983 10/2/2016 Static water level 170 ft. 170 ft. Well production 5 g.p.m. +4.5 g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate G 66 mg/L Arsenic ug/L Date of sample: 10/2/2016 Collected by: Matthew Balzarini B. SEPTICIHOLDING TANK DATA TankType/Material S.T.E.PJSteel Date installed 9/9/2010 Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) YBS Foundation cleanout (Y/N)'YeS Depression over tank (Y/N) NO High water alarm (Y/N) Yes Date of pumping I D�Ic7�l 6 Pumper C. ABSORPTION FIELD DATA' — — Date installed 9/9/2010 Soil rating p.d./ or ftZ/bdrm) 0.6 System type Deep Trench Length 68 ft. Width 2.5 ft. Gravel below pipe 9.7 ft. Total depth 12 ft. Eff. absorption area 1319. ftz Monitoring tube YeS Depression over field No Date of adequacy test 10/2/2016 Results (Pass/Fail) Pass For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 600 gal. New depth 7 in. Elapsed Time: 60 min. Final fluid depth 0 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NO If yes, give date D. LIFT STATION Date installed 9/9/2010 Size in gallons 1500 Manhole/Access (Y/N) Yes "Pump on" level at 44 ' in. "Pump off' level at 43 in. High water alarm level at 45 in. Datum BTM Tank Cycles tested 3 Meets alarm & circuit requirements? Yes E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100'+ Absorption field on lot 100'+ Public sewer main 100'+ Sewer /septic service line 25'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout 100'+ Holding tank 100'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 100'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main -100'+ Water Service line 10'+ Surface water 100'+ Driveway, parking/vehide storage 10'+ Curtain drain 100'+ Wells on adjacent lots 100'+ F. COMMENTS Homeowner has been advised to have the lift station installer test and adjust the pump on/off levels in the lift station to prevent excessive cycling of the pump. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Charles Balzarini Date )U 1 61 1 /(s COSA canary sheet_2-6-15.doc �E °F A�q�gQ :49THv- •: •,... ..... CHARLES G BALZARINI ' FFG •, '%< CE -13854 ,•�` islF • • + 4�lila� PROFESSIONP�.a Municipality of Anchorage u , a Development Services Department Building Safety Division s On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Nitrate Advisory Certificate of On -Site Systems Approval # OSC 161481 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block , Lot I of Contour Acres #1 subdivision. This inspection revealed a nitrate concentration of 6.66 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. Nitrate Fact Sheet From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US 'Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical' methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. f�(/Iy�itiF_►���7iE1 .0 eNr R�eti�enn4 BARN N 39 59 W206,00 au( KK EI Fupc rune ruosE nwEnaFw. ON ruE aE[oao nnr, IRE NOT suovm -. TEUC OF onr7Rns APE'ew n5o An TTCsVsDTDDEr MNE �e W Eery Li xE s Oe Iosi nOx n oom W ni i. W eovEx EuiS E u E "�o P.�E.�F.ACq�ppO 0 9 TH °00. S•law,l, f/�v �4p^; `., sHnNe a Holr ' .oOv Op , LsxsrF ,00 pON000popo��� I AS -BUILT SURVEY 1" = 39' I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT 1, CDNTOUfl ACHES ADD'N. NO. 1( PLAT 67-9S) ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST OTHER THAN NOTED. DATED AT ANCHORAGE,ALASKA THIS _18TH_ DAY OF _OCTOBER 2016. IIIIIE.r IRMO 130@. FS 179-02 a1, ".0 MUNICIPALITY OF ANCHORAGE , DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION F ENVIRONMENTAL HEALTH DIVISION O CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 1. GENERAL INFORMATION �4 ?(0-1053 Application Date °9h v�8c' (a) Legal Description (include lot, block, subdivision, section, township, range) o� 13GccrL /20 CoNToul2 Ac/RlFS 71 AOON. Location (address or directions) (b) Applicant Name jfo13 i6rVDY t(P-4 Telephone: Home 345-7580 Business 399 Applicant Address 6720 A/Lrtrc (31.u0 .r "cI4- 4I<, 955,/8 (c) Applicant is (check one): Lending Institution ❑ ; Owner/builder; Buyer ❑ ;Other ❑ (explain); AA 6E. (d) Lending Institution �/A9Sr 1dATrorr.L BA' K of ANc'�e ephone 2 (o5,^ 3 0 6 6 114 /-.o, loo7Zo 14 a KIC Address 15�o TFAHH 6 H06A u-1 Ar/ IC 4ee UjEyr .1 .a'06.cAl' .4J!9, !!)Ci Sin — 07A0 (e) Real Estate Company and Agent ,H.1 -A Address Telephone (f) Mail the HAA to the following address: 1�� 9=11_117 - 2. TYPE OF RESIDENCE Single -Family Multi-Family 0 Other Number of Bedrooms 3. WATER SUPPLY 0 Individual Well Community ❑ Public ❑ Note: If community well system, must have written confirmation from the State Department of,Environmental Conservation i attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, musfihave written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 72-025 (11/84) Page 1 of 2 5 , Individual Well Community ❑ Public ❑ Note: If community well system, must have written confirmation from the State Department of,Environmental Conservation i attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, musfihave written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 72-025 (11/84) Page 1 of 2 5. ENGINEERING FIRM PROVIDING ;PECTIONS, TESTS, FILE SEARCH, DAT. ND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Muoci_pal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm —46H&P-O" 6-1 61 "Oe d ice. G y� hONA& C ' Telephone 39 q ' -7 Address 7fco 040 ScEwAnd +Nwy Q/Y;7- T Date Engineer's Seal q..� OF At %%I e • ® S$, TH S•eei•0 • • • •i•r•� A1be I.. Swank Jr. ? �� ��•• CE -4910 2q 1111% PROFESSY3%- 6. DHEP APPROVAL n Approved for bedrooms by Xd Date _ Approved Disapproved Conditional Terms of Conditional Approval CAUTION The Muncipality, of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72.025 (11/84) MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE (MOA) DEPT. OF HEALTH & HEALTH AUTHORITY APPROVAL (HAA) ENVIRONMENTAL PROTECTION CHECKLIST - FEBRUARY 1984 264-4720 SEP 2 260 Legal Description: 1-07' s4n C K GoN7'oul2 ,4C/2ES T 9DDN A. WELL DATA Well Classification P12 ua i-1� If A, B, C, D.E.C. Approved (Y/N) N 1A Well Log Present (Y/N) YoES Date Completed 3 /7 /8-3 Yield 5- GPM Total Depth 3o Cased to j SoFr Depth of Grouting N 1 Static Water Level ) `7 oPr- Pump Set At z 7 3 re -- Casing Height Above Ground /N506 di 40400) Sanitary Seal on Casing (Y/N) YES Electrical Wiring in Conduit (Y/N) /VO Depression Around Wellhead (Y/N) 140 Separation Distances from Well: Fes. To Septic/Holding Tank on Lot Z 35 ; On Adjoining Lots IN 1A To Nearest Edge of Absorption Field on Lot 2 So ; On Adjoining Lots Iq�,q To Nearest Public Sewer Line N 1 To Nearest Public Sewer Cleanout/Manhole NIA To Nearest Sewer Service Line on Lot gs fit. Water Sample Collected by LAI -,taper/ fM6/"t-AXIrrG ; Date�`— ,01 Ar+AG -_ rT' Water Sample Test Results Sp+-r1re4cr:e✓L�4 4—_2 Comments B. SEPTIC/HOLDING TANK DATA Date Installed Size 25p 6AL No. of Compartments 2 Standpipes (Y/N) yeS Air -tight Caps (Y/N) YCS Foundation Cleanout (Y/N) YtS Depression over Tank (Y/N) go— Date Last Pumped 9'/8(�' Pumping/Maintenance Contract on File (Y/N) A/o ; for Holding Tank High -Water Alarm (Y/N) /10 Temporary Holding Tank Permit (Y/N) Separation Distances from Septic/Holding Tank: To Water -Supply Well Z 3 S �t To Building Foundation To Property Line �D fit' To Disposal Field 5o 1t. moi` . To Water Main/Service Line -4 Z,4 To Stream, Pond, Lake, or Major Drainage Course Comments Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata 26_6 fl- Type of System Design 644C" A:1e(,V Date Installed V/ -)? Length of Field 68 fr; Width of Field 3 icr Depth of Field _ 4f't �o top Gravel Bed Thickness 6Ft Square Feet of Absorption Area 8/6 Ft " Standpipes Present (Y/N) YES Depression over Field (Y/N) /y0 Date of Last Adequacy Test Results of Last Adequacy Test 9 /65 GA oAiN. Separation Distance from Absorption Field: To Water -Supply Well 45o f7—, To Property Line 610f f • To Building Foundation __ 6 5 Ff'• To Existing or Abandoned System on Lot Nig ; On Adjoining Lots xi Iia To Water Main/Service Line go rCfi. To Cutbank (if present) - HAA To Stream/Pond/Lake/or Major Drainage Course N/A To Driveway, Parking Area, or Vehicle Storage Area Comments D. LIFT STATION HIA Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) _ Comments Dimensions Manhole/Access (Y/N) "Pump Off" Level at ** Check Permitted Bedroom Rating Against HAA Request ** Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA I certify that I h v checked, ver] fied, or conformed to all MOA and HAA guidelines in effect on the date of this inspection Signed Date _ o (o Company LArr��n,ivrrGz.rcrt�¢ir�; MOA No. Abp e )4rlHA60",e"-' Receipt No. flew 4&&1 r a&o _�, OF A Date of Payment 7a-'a•-'R6l.e �,�� •°' °j•., �S,j„ @� �;:.., or C2' °�° '� ® Engineer's Seal Amount: $ (.5 so01 a 49 o I� `g. Alberti., Swan Jr. w Page 2 of 2 CE.4910 ••° ;t 72-026 (11/84� a� PR0FESSi`3k\�` 5.E-GGA�L DESCRIPTION DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DA DATE ® SINGLE FAMILY ❑ Two ❑ Five ❑ MULTIPLE FAMILY INSPECTOR INSPECTOR INSPECTOR 1' INDIVIDUAL* MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPT. OF K'ALli I & DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTFbINIRONMENT;\L i fLCTION 825 L Street - Anchorage, Alaska 99501 8. SEWAGE DISPOSAL SYSTEM � fAAY2 c; 1981 ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 RECEIVED REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTY OWNERPHONE Ob 6, L;ncoca. F&b LCLn 139.5-3999 MAILING ADDRESS P.o. &)u 10 -eau Anc oraG A1C ga511 PROPERTY RESIDENT (If different from above) PHONE ji00man Rd . dame 50 -MC 2. BUYER oqd W (1t L� MC Con PHONE 333-9000 MAILING ADDRES 6y 70 e6617- �ed. 1�nc1?olW P Kx_6x1 3. LENDING INSTITUTION /,57'" 12ahgnal ant ESoalA tee $rnnc PHONE Xle-6.300 MAILING ADDRESS 9 0 O�Cc6 / cl cl�"v9 4. REALTOR/AGENT Polar /&e& / PHONE r MAILING ADDRESS 5.E-GGA�L DESCRIPTION Ci J drlc STREET LOCATION /6 0�_ h/-"mccr� �d . Ir TYPE OF RESIDENCE NUMBER OF,BEDROOMS ❑ One ❑ Four ❑ Other ® SINGLE FAMILY ❑ Two ❑ Five ❑ MULTIPLE FAMILY [9 Three ❑ Six 7. WATER SUPPLY 1' INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM ffW INDIVIDUAL/ON-SITE** iCl Q YEAR ON-SITE SYSTEM WAS INSTALLED. ❑ PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. 6/79) 44^ v THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE ❑ OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON -SITE ❑PUBLIC UTILITY Connection Verified PERMIT NUMBER DATE INSTALLED _ (g INSTALLER ❑Septic Tank or ❑ Holding Tank Size: If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL _ 4. DISTANCES WELL TO: Septic/Holding Tank Absorption Area 7Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS ( APPROVED FOR BEDROOMS ❑ CONDITIONAL APPROVAL (letter must accompany certificate) ❑ DISAPPROVED DATE r_ f BY /x4p 72-010 (Rev. 6/79) of 826 "L" STREET (901) 2644J''I I GIFEORG157114. SULLIVAN, MAYOR DEPARTMRra OF HEMJH &D ENVIRONNIENTAL P!7,07ECIAON May 28, 1981 1 4 k Joe/Linda Fabian Post Office Box 10-824 Anchorage, Alaska 99511 Subject: Lot 1 Block I Contour Acres Subdivision A Approval for the individual sewer and water facilities cannot be granted until the following items have been completed: (1) The water analysis report needs to be submitted to this office from the Chem Lab, 5633 B Street, for ou review, Effective June 1, 1981, the fee s$ (2) The septic tank pumped with. a receipt submitted, to this office. (3) An adequacy test need sAo be performed on the existing leaching area. This test will determine if the system is adequate according to National Standards. A listinci of private firms performing the test is enclosed. This report needs to be submitted to this office for vour review. n if there are any further questions, please call this office at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist RCP/Ijw cc: First National Bank of Anchorage Post Office Box 4-2090 99509 Polar Realty ,1.101 East 76th Avenue 99502 .i r =116 VI_ GIIV IF VIIIIICIII:Q l l(UG 11 �y re t Anchorage, Alaska 99503 274-4561 Date Received April 14, 1976 r Time of Inspection CY Date of Inspection A` REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES a `1� 4611 FOR �ilz. L�1,S GLO. . `L�.alai X71 Conv/V.A. nl`tSG i 1. Approval requested by: Area Inc Realtors % $kell Goens Mailing Address: 3300 C Street Phone: 278-2.525 2. Property Owner: Fred Mugger Phone: 344-1'19.0 Mailing Address: Huffman Road 3. Legal Description: Lot 1 Block 1 Contour Acres #1 4, Loaonc 2h miles up Huffman on South side of road 5. ` Type of facility to be inspected Single Family No. of bedrooms 4 :a 6. Well Data: individual serving one (2 functionabl:e wells on property) A. Type B. Depth C. Construction D. Bacterial Analysis 7. Sewage Disposal System: on—site system A. Installed 1966 B. Installer C. Septic Tank: =1 Size 2. Manufacturer D. Seepage Pit: 1. Absorption Area 2. Material E. Disposal Field: Total length of lines 8. Distances: A. Well to: Septic tank Absorption area Sewer tines Nearest lot line Other contamination B. Foundation to septic tank Absorption area C. Absorption area to nearest lot line EQ -034 (1/74) Page l of two pages MUNICIPALITY OF ANCHORAGE GREATER ANCHORAGE ARE,'-, BOKuUGFI DEPT. OF HEALTH & VIRONMENTAL Pi<pTLCTION Department of Env ironmentaI Qua Iit 3330 C St., Anchorage, Alaska 99503 - 274-456 1976 REQUEST FOR APPROVAL. OF RECEIVED INDIVIDUAL_ SEWER & WATER FACILITIES CONV ✓ A 1. Type of Inspection: CAIRO ___ V -__ ✓ F{-iA 2. Property Owner: -- �«^ Da Phn 4 ne w4_/"/2'0 4. Mailing Address: --- N a r+. Buyer: Alai 1 i ng Address: Da.y.Phone Name of Lending Institution: - --- Mailing Address. ---- -- 5. Name of Realtor or Agent: Mailing Address: S tom- �44� C6h� G. Legal Description: Facility to be inspected: _- No. Bdrrns�. _ + 7. .Type of - . 8. Water Supply Type of Public Utility Individual ✓ �„ Supply: If Individual, number of dwellings presently served 1 If Individual, depth of well ? g. Sewage Disposal System _. _ Type ,of System: Public Utility Individual (on-s7te) n d i d u al , d a t e o � i r i s 't -I 'I a t i o n � Phone Page 2 of two pages - Re st for Approval of Individual er & Water Facilities Legal ` Description Lot 1 Block 1 Contour Acres #1 Approved Disapproved Date,, Approval,Valid for one year from date signe Greater Anchorage Area Borough, Department of Environm al Quality DIAGRAM OF SYSTEM �I certify that the information contained in this request for approval to be a true and accurate representation of the: subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ -034 (1/74) Y 6, 1976 4.1 AUSU.B.A. rederal Credit Union 777 Juneau Street nra+eIla $OSOI Subjoati Lot 1 Block 1 Contomr a #1 Dear SIra Th* v*ll now sere this art is satisfactory regurdinq well Owwtraction aad viten quautyo Ta saa"d vel1 must be as per the �►r+�i�r�e. UVOU the Sale of this lot an au0b"At bwt be Geta lishi ed to install a MW uwftc system aw Properly wMadon tb second swell. A *oil taut watitd establish the sp*cificatims, for the a+ aaftr system. xf you have any further qa"ti , plaasa a tett. this office at 276-2221,E extension 245. Si ly * Les M. NVOWMIS eeaitariaa z Skall Gown Arca Realtors Inc. F, . �.✓ Q W F- U_ > O W � �rnd �CY�� Y(n� Z N 00 ! d (La'a �a3w� d EodoCK= A- o a. -4 ViZtNOU cn L) a� Q Q V% �.✓ Q W F- F -- !� O LR f- �CY�� O Zaogcl o-�=m< S� a3a a¢ c CL E(4aC=L cn L) V Q Q V% k W ntr �J 0 0 U, N. UJ � Q Q F- F -- O f- Z Q 'U 0) } 9 F- N n N O c—I N