Loading...
HomeMy WebLinkAboutCONTOUR ACRES #3 BLK 2 LT 5Contour Acres #3 Block 2 Lot 5 #017-381-04 Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page 1 of ON-SITE WASTEWATER INSPECTION REPORT I Permit Number: OSP151129 PID Number: 017-381-04 Dwelling: ❑t Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑E Upgrade Name: Frank Bethard ABSORPTION FIELD ❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 12801 Reata Drive Anchorage, AK 99507 ❑■ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot Contour Acres No. 3 2 5 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ft2 Ft. Well >100' NA NA NA NA TANK ❑■ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1 1,250 Gal. Surface Water >100' NA NA NA Material Number of compartments Lot Line >5' NA NA NA Steel Two NA Foundation >5' NA NA NA LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Only the Septic Tank Replaced Under Pump on level at in. Pump off level at in. High water alarm at in. This Permit. Exisiting Septic Tank Decommissioned in Accordance with Pump make and model Electrical Inspections performed by Municipal Code. Installer PIPE MATERIAL House to tank D3034 aankto drinfield D3034 G&S Excavating Drainfield CO/MT Inspector MEA BENCHMARK (Assumed elevation) 100.0 ft Inspectioni51 5/22/15 5/22/15 Location and description dates: 2�d 3rd 41h Back Deck. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL 4# OF At��' Conditional Approval: Date awl, 1, o`�p•olos•e °�S ®d 49TH C e �9.... e.. e... coo v wr.C.eoe .. °j..a..ee...ee..o................... �J s MICHAEL E. ANDERSON : 00 S J,•. CE - 4381 .. Approved "zfz'_A � Date ®��� a�-► 1317 inspection rceporr_a-i--izaoc Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK 99519-6655 - 343-7904 *n -Site Wastewater Disposal System or Well Inspection Report I 96.3 E)Mng /FWhd Ground Ground 1,250 Gallon 8.7 Septic Tank 8.5 Tank Only Replaced Under This Permit. Existing Tank Decommissioned in Accordance with Municipal Code. UP, No Scale On -Site Water and/or Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151129 Tax Code Number: 01738104000 Work Type: SepticTank Upgrade Permit Effective Dates: May 15, 2015 to May 14, 2016 Design Engineer: ANDERSON ENGINEERING Subdivision: CONTOUR ACRES #3 Site Legal Address: CONTOUR ACRES #3 BLK 2 LT 5 G:2837 Owner/Address: BETHARD FRANKLIN O JR & JANIS K 12801 REATA DRIVE ANCHORAGE AK 995163019 Site Mailing Address: 12801 REATA DR, Anchorage This permit is for the construction of: N Disposal Field Y Septic Tank N Holding Tank N Privy Lot Size in Sq Ft: 116250 Total Bedrooms: 4 N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By, MUNICIPALITY OF • Community Development Department Development Services Division On -Site Water & Wastewater Program Parcel I.D. Phone:907 Fax: 907 ON-SITE SEWER/WELL PERMIT APPLICATION 017-381-04 Property owner(s) Franklin & Janis Bethard Mailing address 12801 Reata Drive Anchorage, AK 99516 Day phone Site address Same Legal description (Sub'd., Block & Lot) Contour Acres #3, Block 2, Lot 5 Legal description (Township, Range & Section) Lot Size 116,250 Sq. Ft. Number of Bedrooms Four APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑x Upgrade MX Duplex (D) ElHolding Tank F-1Renewal F]Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. property owner of Permit/Rush Fees: 31-1 L4— Waiver Fees: Date of Payment: ��5 Date of Payment: Receipt Number: n, Receipt Number: Permit No. Waiver No. Permit App__- : . :'-.,:c 2015 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) May 15, 2015 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 5, Block 2, Contour Acres Subdivision No. 3 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer The septic tank on Lot 5, Block 2, Contour Acres Subdivision No. 3 has failed and must be replaced. We are proposing to replace the tank with a new 1,250 gallon septic tank to serve the four-bedroom duplex on the lot. We are therefore requesting a permit be issued for the construction of a new septic tank. The attached Site Plan and backup documentation identify the location and configuration of the existing septic system and the location of the new tank. Also identified on the plans is the existing well on the lot. The subdivision is served by a community water system. The existing tank and lift station on the lot will disposed in accordance with Municipal Code. The drainage patterns on the property will be maintained after construction. The ground surface on the lot slopes to the southeast at a 3% grade in the area of the new tank. The tank will be placed in the same location as the existing tank at nearly the same elevation. It will then be tied in to the existing service line. If the tank is constructed in accordance with our design the following statements apply: 1. The tank, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The tank, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The tank, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. Lot 5, Block 2, Contour Acres No. 3 May 15, 2015 Page 2 of 2 4. The tank, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 0 49th MICHAEL E ANDERSON ._ No. CE -4381 i C I I � I I I I 1 C m ® I I CD 0 iI Ji L _-_________-___-__-_-_________________-_�WIIII x _ 3__ _____________-_ ________ __o_ ___ __-_______________ 9 _ I w W a � N I i CJ I I I I 3AIua V1V321--------- LO Nt w m '�•, p ■ ' S • •�4iww�ww'w� 10' UTILITY EASEMENT S 00'01'13"W 250.00' --_—_—____-I —____—_--_ 81 1 L>J WL N l0 C m > CC Um p O p e m a m E �o •ac o ti.. oOm hn o c m— wo $ E upimO U n Ocxca 0 O O N 'C O O 2 p r d C 'J pppplllI 0 4 m ~00 inQ 4 003;1�f Ipl ZNwX V O•I ^oma cd� WFU200 J� pN w ds r0 ice_— —� O'xa cmcc o ow U O m t p n c c c 0 0 W E�a�cmeo \ WO E m'Oc ov o:.-os0. Nri one—cm3 O ons c���� T \\• 3 O N Z N V LO I w O _® 1CD J vi d x3 I I w rw a W /�\ o J W In o Q (0 V) n n 00 / ;sNLO z 3+ V/ Inx m • In w s O 00 3'o 00 Z \\ / W—a O �mtM Em (n Ozi.ac v0i O U Ap %� S: •w ♦U�''. m9 :a z a. 1♦�� ; uAV S 0901'00"E 250.00' ♦♦♦♦ ®,,:,`;�+.�5.�� 3AIma VIV38 GREA, ER ANCHORAGE AREA BORvdGH 0011;Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME MAILING ADDRESS G71114VZ ' 570 C _^ PHONE3W_ V LOCATION /1 �`l�L_ �17� LEGAL DESCRIPTION 40T. � S [-IA f�. nly7ooe ':S SEPTIC TANK: DISTANCE V NUMBER OF FROM WELL MANUFACTURER MATERIAL COMPARTMENTS INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITYXn GALLONS. TILE DRAIN FIELD: / a % TOTAL LENGTH y� l DISTANCE FROM WELL/�FOUNDATION�%/11/_NEAREST LOT LINE OF LINES NUMBER OF LINES DISTANCE BETWEEN LINES L1_V-A&-TRENCH WIDTH.1k IN. TOTAL EFFECTIVE ABSORPTION AREA SQ. FT. LENGTH OF EACH LINE `r DEPTH OF FILTER �iT DEPTH: TOP OF TILE TO FINISH GRADE '�7 MATERIAL BENEATH TILE / a Ali. ABOVE TILE IN. WELL: Ilio% ye -7- 0CMIAA0 TYPE CONSTRUCTION BUILDING NEAREST NEAREST SEPTIC FOUNDATION , LOT LINE , SEWER LINE , TANK- CESSPOOL ANK_ CESSPOOL _ APPROVED_ DISTANCES: , OTHER SOURCES DISAPPROVED REMARKS INSTALLED BY)-/ /� r SEWER LINE DEPTH: PIPE MATERIAL: ��` % AOAI In Pte, . LOT SLOPE: -Sr REMARKS: Form EQ -032 DEPTH DISTANCE FROM: SEEPAGE SYSTEM_ DIAGRAM OF SYSTEM SIV lot qwk q71 ISO� DATE�4495tZZ APPROVE G.A.A.B. \ . ISSUED ... ..... �... ..... ... ;&N CA F:7 101 PON CS 1-41 CA FT F4 C3 EF _ DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 'L' STREET ANCHORAGE, HK 9950:1, ' 'k/ 279-2511 �~ �54 V> CA tA--- III 1 0- EF ST FIT 0.11 IF;;!! �IF.*.ii:: IF;;!! � PERMIT NO. ( 77455 ) X� APPLICANT B SRH BOX 1578X ` 344-8006 LOCATION REHLTH DR LEGHL 1 5 82 CONTOUR ACRES #] LOT SIZE 115869 SQUARE FEET TYPE OF SOIL HBSORBTION SYSTEM ISi TRENCH MAXIMUM NUMBER OF BEDROOMS = 5 SOIL RATING (SQ FT/BR)= 150 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: �Ir T H --u= 11L et L. EK 011 (11 -1- 1-1= a* k 0::::::- 11= � THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRHINFIELD. THE DEPTH OF H TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET), THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL. DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). 091 FEZ (it 11.3 1 & EF 13 FIT F, w x c:-, ������� 1: IF -11 11 H���� IF .-m ����� ������ H PACKAGE PLANT MAY BE INSTALLED AT THE PERMITTEE'S OPTION SUBJECT TO THE FOLLOWING CONDITIONS: 1. EITHER H CLASS I OR II NSF APPROVED PLANT MAY BE INSTALLED. 2. H CONTINUOUS MAINTENANCE AGREEMENT IS REQUIRED. IF H MAINTENANCE AGREEMENT IS NOT KEPT CURRENT YOU MAY BE REQUIRED TO ENLARGE THE SOIL ABSORPTION SYSTEM HND/OR YOU MAY BE SUBJECT TO PROSECUTION. ..... ..... ........ _..... ___________.... ... _____________.... ......... ....... ...... .......... .... ..... ..... ......... ___ 0- 0A 1:) < oil > 1: 1 FREFE> BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN H WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR H PRIVATE WELL OR 200 FEET FOR A PUBLIC WELL WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS OF THE WELL COMPLETION OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. 1=4 IE: 151 1wl :1 0- ����III­*.��!:EE.,-, NET C:� FEE 1-113 FI: It! 13V ;I.,, YR. you 77 7" I CERTIFY THHT 1: I HM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. ]: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE 15 REMODELED INCLUDE MORE THAN 5 BEDROOMS. � / \` U9 /? " --------- —,& - � /o'' n�PLICHNT FRHNK�G�T HR ^ ''^ ' ' '''' ' ~ consttuetion Beit _fab "One test is worth a thousand opinions" 2204 Cleveland Anchorage] Alaska 99503 - Performed For Frank Bethard Date Performed 6/21/77 Legal Oescrintion: Lot 5 Bloc: 2 Subdivision Contour Ames 4 This Form Reports Soils Lon yes Percolation Test_ Denth Feet Soil Characteristics 2 — - — 4 — Brown Silty Sand 6 8- 10 — Brown Slightly Silty Sandy Gravel, with occasional 12 — boulders 14—,, 16- 18 Bottom of Test Hole 20— Was Ground Water Encountered? No If Yes, At what Depth? Readinq I Date -j Gross Time `rl o�10 DE I — 0 Net Time Depth to H2O Net Dron Percolation Rate Minute Proposed Installation: Seenaoe Pit Drain Field Depth of Inlet Depth To Bottom Of Pit Or Trench CnMMENTS: 150 Sq Ft drainage area required per bedroom from —6 to 18 feet. Test Performed By — Data Certified By:CONSTRUCZ TEST LA: David Paul Date' 6/22/77 _ ENKINS WELL DRILLING f P.O. BOX 3-142 ECB ANCHORAGE, AK 99501 - PHONE 344-3;97 - 15 ft"nber 11-77 DRILLERS WELL LOG CUSTOMER S 11 _ e---���., -97j—T— A 97j- i LOCATION Tot 5, 111ork 2, �o1� A +� � + i w � gid.) SIZE 6" DEPTH n CASING DEPTH 157 _ GROUTING DEPTH _ — YIELD 4 + 1* 80 STATIC WATER LEVEL HOW TESTED PUMP INSTALLED IP ftv 1�r TYPE * ' FORMATIONS ENCOUNTERED AND APPROPRIATE DEPTHS TO TO T035 Ton =xailt dirt 38 TO79 ' Am rrwm1 v►%c"flo"al bmldw 78 t' �, v):�en + ► T0� 90 send gmvolg 1~v ,J/!1 -6I -my TO12D 1po 5 wmdt 01-9"an -mewl "00about 11 -IL TO 155 Vo soft oba1e W/blue Play TO !Vo. . Tp w/of-emvl-nal.. herd rook stroaks blue n1a In anktIrspo TO TO TO TO TO t MUNICIPALITY OF ANCHORAGL P JDepartment of Health and Environmental Protection 4C� 825 L Street, Anchorage, Alaska 99501 264-4720 equest for Approval of Individual Sewer and Water Facilities 1. Property Owner: 2. 3. OF ( KATN1 F_ Mailing Address: SEA 16f? _q K Phone: U-2 1?00 4r, Name of Buyer: :54&E AS Mailing Address: Phone: Lending Institution: /(,),47_/DA_)/4L E,41y1<' Mailing Address: Realtor/Agent: /V O&V G Mailing Address: Phone: ;2-7 6 /�3x Phone: 5. Legal Description: ZOT 67 eL Street Location: /U111V 7-4 ��• 6. Single Family Residence: Multiple Family Residence: (k4"� Number of Bedrooms: ( ) Number of Bedrooms: 7. Water Supply:„ *Individual Well (jK Public/Community System ( ) If Individual Well, well depth If Community System, name of system 8. Sewage Disposal System: *�bn-site System (kj' Public System ( ) If On-site System, date of installation: "% —7 7 *NOTE: A well log is required on ALL wells drilled since 6/75. **If on-site sewer system is over two(2) years old, an adequacy test is required by this department. A fee of $25.00 must accompany each request before processing can be initiated. 3/77 SENT TO POSTMARK OR DATE STREET AND NO. P.O., STATE AND IIP CODE - l _ OPTIONAL SERVICES FOR ADDITIONAL FEES 00 I.Shows to whom and date delivered 15¢ RECEIPT With delivery to addressee only ...... 650 Rid - SERVICES 2. Shows to whom, date and where delivered .. 35¢ With delivery to addressee only ............ 850 DELIVER TO ADDRESSEE ONLY ...................................................... 504 SPECIAL DELIVERY (extra fee required) I ................................... PS F SENT TO POSTMARK OR DATE STREET AND NO. P.O., STATE AND IIP CODE - l _ OPTIONAL SERVICES FOR ADDITIONAL FEES RETURN I.Shows to whom and date delivered 15¢ RECEIPT With delivery to addressee only ...... 650 SERVICES 2. Shows to whom, date and where delivered .. 35¢ With delivery to addressee only ............ 850 DELIVER TO ADDRESSEE ONLY ...................................................... 504 SPECIAL DELIVERY (extra fee required) I ................................... PS F orm - Apr. 1971 3800 NO INSURANCE COVERAGE PROVIDED— (See other side) NOT FOR INTERNATIONAL MAIL GPO :1972 Oma -480-743