HomeMy WebLinkAboutCORONADO BLK 2 LT 5Coronado
Block 2
Lot 5
#050-121-15
K 1 V LJ ENGINEERING, INC.
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
SOILS PERCOLATION TEST
Performed for: Joe Morris Date Performed: 5/17/06
Project: Coronado B2, L5 TEST HOLE #
Depth
18-
20-
ORG/OL SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
SW -clean sand w/ occasional
cobles 6-10'
B.O.H.
Was Ground water encountered? NO What depth? NA
Depth to water after monitoring? DRY Date? 5/24/06
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
2
3
4
5
6
VISUAL 125 SF/BDRM
7
8
9
10
11
12
Water
Added
Percolation RateVISUAL (min/ in) Perc Hole Diameter_
Test Run Between feet and feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State guidelines in effect on this date.
GAAB-HD-I GPcATER ANCHORAGE AREA BOROtle H
HEALTH DEPARTMENT
327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME
LOCATION
MAILING 2 / x'`25
ADDRESS7�- 7 �'�'� HONE—
A,
ONE
/ i! B
EGAL DESCRIPTION
SEPTIC TANK: v�-+�Da
NUMBER OF /
DISTANCE FROM WELL S 47 MATERIAL COMPARTMENTS
LIQUID CAPACITY �(j —GALLONS. INSIDE LENGTH INSIDE WIDTH DEEPTHD
SEEPAGE SYSTEM:
SEEPAGE PIT:
NUMBER OF PITS / OUTSIDE DIAMETER –0 --OR WIDTH, LENGTH, DEPTH_,
LINING MATERIAL DISTANCE FROM WELL r�/j� BUILDING FOUNDATION/
NEAREST LOT LINE TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) v A SQ. FT.
TILE DRAIN FIELD:
DISTANCE FROM WELI
FOUNDATION , N
TOTAL LENGTH
OF LINES
NUMBER OF LINES DISTANCE �LENG�THOF
TRENCH WIDTH IN. TOTAL EFFECTIVE
ABSORPTION AREA SQ. FT.EACH LINE
DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE
Off
W ELL:fVoI- /Al %!� DISTANCE FROM WATER
TYP , DEPTH BUILDING FOUNDATION.�SAMPLE NEAREST
NEAREST SEPTIC SEEPAGE OTHER
LOT LINE SEWER LINE—,TANK SYSTEM CESSPOOL , SOURCES
DIAGRAM OF SYSTEM
DISTANCES:
C�
37-
DATE 14:VI15 IoI7 APPROVED
HEALTH AUi ORITY
GAAB-HD-2 GREATEI,, ANCHORAGE AREA _ JROUGH Case No.
HEALTH DEPARTMENT
327 Eagle St. Anchorage, Alaska 99501 279-2511
SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT
NAME OF APPLICANT .:Z COJF- MAILING ADDRESS 7_2 PHONE N0.���"���
RESIDENCE ADDRESS LOCATION OF INSTALLATION
LEGAL DESCRIPTION 'C j
56' 7POaG1:S
APPLICATION TO INSTALL: SEPTIC TANK V , SEEPAGE PIT V , DRAIN FIELD , OTHER
TO SERVE THE FOLLOWING FACILITY 3 -Bp (am
FINANCED THROUGH TO BE INSTALLED BY
PERCOLATION TEST RESULTS ANTICIPATED DATE OF COMPLETION 24 AJoY7Le
BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT
,� ���_ , PERMIT TO INSTALL A
THIS IS TO SERVE AS n�
AS DESCRIBED BELOW, SIZE OF UNIT TO BE SERVED 8Dko"l �
SEPTIC TANK SIZE A TYPE s TFZ!�I— SEEPAGE AREA TYPE Lac
I ce,6Py that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No
above described system is in accordance with said code.
DATE ` � APPLICANTS SIGNATURE '^G '
( %6A
rl h,..l s
MUNICIPALITY OF ANCHORAGE
MUNICIPALITY -0' ANCHORA
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION DEPT. OF N_ ff`&
825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL PPOTE-CTION
•
ENVIRONMENTAL ENGINEERING DIVISION
,JUN 12 1981
Telephone 264.4720
NUMBER OF BEDROOMS
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEINEFRE0 SSE Q
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Pleases allow ten (10) days for processing.
1. PROP T OG� ¢.
X Two ❑ Five
(O HONE'/or Q
MAILING ADDRESS
7. WATER SUPPLY
PROPERTY RESIDENT (If different from above)
❑ INDIVIDUAL*
PHONE
z. Bu ER
since June 1975. For wells drilled prior to that date, give well
PHONE
6 ge
MAIL NG ADDRE
8. SEWAGE DISPOSAL SYSTEM
3. LEN iNG INSTITUTIO /
INDIVIDUAL/ON-SITE**
PHONE
If system is over two (2) years old an adequacy testis required
❑ PUBLIC UTILITY
AILING ADDRESS loor/
3 s" S
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
.5 ,�� 7L k u&
4. TO/R/AGENT
I PHONE
Al G ADDRESS
5. LEGAL DESCRIPTION
( (2
,ola-/ 6--.4
N/-�a�c,
STREET LOCAT ON
6. TYPE OF RESIDENCE
NUMBER OF BEDROOMS
SINGLE FAMILY
❑ One b four ❑ Other
X Two ❑ Five
ED MULTIPLE FAMILY
❑ Three ❑ Six
7. WATER SUPPLY
❑ INDIVIDUAL*
ATTACH WELL LOG. A well log is required for all wells drilled
0 COMMUNITY
since June 1975. For wells drilled prior to that date, give well
❑ PUBLIC UTILITY
depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
**If
INDIVIDUAL/ON-SITE**
individual/on-site, give installation date l /.
If system is over two (2) years old an adequacy testis required
❑ PUBLIC UTILITY
by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
iz-viu�s/iui
THIS SIDE FOR OFFICIAL USE ONLY
INSPECTION APPOINTMENTS
DATE RECEIVED.
TIME
TIME
TIME
DATE
DATE
DATE
INSPECTOR
INSPECTOR
INSPECTOR
DIRECTIONS:
1. TYPE OF RESIDENCE
❑ SINGLE FAMILY
❑ MULTIPLE FAMILY
NUMBER OF BEDROOMS
❑ ONE ❑ THREE ❑ FIVE ❑ OTHER
❑ TWO ❑ FOUR ❑ SIX
2. WATER SUPPLY
❑ INDIVIDUAL
❑ COMMUNITY
❑ PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM
❑ INDIVIDUAL/ON -SITE
❑ PUBLIC UTI LITY
Connection Verified
PERMIT NUMBER
DATE INSTALLED
INSTALLER
❑Septic Tank or ❑ Holding Tank
Size: If Tank is homemade
give dimensions:
SOILS RATING
TYPE OF TANK
MANUFACTURER
TOTAL ABSORPTION AREA
MATERIAL
4. DISTANCES
WELL T0:
Septic/Holding Tank
Absorption Area
Sewer Line
Nearest Lot Line
Absorption Area to nearest Lot Line
5. COMMENTS
APPROVED FOR Z— BEDROOMS
❑ CONDITIONAL APPROVAL (letter must accompan; cer ficate)
❑ DISAPPROVED
DATE
BY (Title)
LEGAL DESCRIPTION
72.010 (Rev. 3/78)
W-.1',,AH I INM N1 Of- HUIJI I ANO EMIMONMENT,1 L PRO1 FCI'I()N
June 19, 1981
Ed.sel L. /Margaret E. Scott
% Dolores Oesau
Red Carpet Greatland
Box 633
Eagle River, Alaska 99577
Subject: Lots 5 and 6 Coronado Subdivision
Approval for the individual sewer and water facilities
cannot be granted until the following i -L( ---ms have been
completed:
(1) The septic tank pumped with a receipt submitted
to this office.
(2) The cleanout on the septic tank needs to be raised
above ground level. This will need to be reinspected
by this office.
(3) An adequacy test needs to be performed on the exist'.ing
leaching area. This test will determine if the system
is adequate according to National Standards. A listing
of private firms performing the test is enclosed. This
report needs to be submitted to this office for our
review.
If there are any further questions, please call this office
at 264-4720.
Sincerely,
Robert C. Pratt, R.S.
Associate Specialist
RCP/ljW
cc: Home Federal Savings and Loan
535 D Street 99501
kQ a a
Mun�dpafiity
Anchora- -o ce
Z)I-flF T
825 "t-" -E 71qlr-I
Is I/ A 9 9 5 0
ANCHCMAGU, AlLiV
100/) 264-4111
CEop. S U 1- L I V,� N,
MA) OP
W-.1',,AH I INM N1 Of- HUIJI I ANO EMIMONMENT,1 L PRO1 FCI'I()N
June 19, 1981
Ed.sel L. /Margaret E. Scott
% Dolores Oesau
Red Carpet Greatland
Box 633
Eagle River, Alaska 99577
Subject: Lots 5 and 6 Coronado Subdivision
Approval for the individual sewer and water facilities
cannot be granted until the following i -L( ---ms have been
completed:
(1) The septic tank pumped with a receipt submitted
to this office.
(2) The cleanout on the septic tank needs to be raised
above ground level. This will need to be reinspected
by this office.
(3) An adequacy test needs to be performed on the exist'.ing
leaching area. This test will determine if the system
is adequate according to National Standards. A listing
of private firms performing the test is enclosed. This
report needs to be submitted to this office for our
review.
If there are any further questions, please call this office
at 264-4720.
Sincerely,
Robert C. Pratt, R.S.
Associate Specialist
RCP/ljW
cc: Home Federal Savings and Loan
535 D Street 99501
NVO $4001 L. Seatt
box 7*3
Sade River$ Alaska, 0"77
tpWdCTs Cos syadoSubdivist000
Basle liver, Alaska
goer ifs►. Scott r
This is to Aire out merit seavoriaties rosaWas the water
Ilse exteraioa s Iota Ceram& diwisios.
The Stats of Alaska, Adwiaistrtiw Code, SW tslo 1,
"Water Supply," Station goo -psis "quires prsllaftor r plan
sabeiasiaas for sWidLvisior water Ifto *atmwLawo All drawings*
sposifieftle ►as, +a�i�iid,,ather +d a w at be preop ►red ► a rogtots ,�
profsesiaoal sagiosere,
Bowles" is a cagey of Subehapter Is "Water supply, for yaw
inrraimtiar, *tattoos tpe thra tss ass reelt helpful in required
design oube#ssice faro,
ploase consider this letter as dor notice to esa w an fWther
wends on the project until plans hats been submitted and approved.
UVIn R. L. OUNCAN, Me C.
medical Director
iXr
W. IMUMV;
inill
dRslsrr
010ow RECEIPT FOR CERTIFIED MAIL -206
co
M
C.O
N
N
•
SENT TO
POSTMARK
OR DATE
STREET AND NO.
CITY, STATE, AND ZIP CODE
EXTRA SERVICES FOR ADDITIONAL
FEES
Return Receipt
Deliver to
Shows to whom Shows to whom,
Addressee only
and when when, and where
delivered delivered
❑
❑ m fee ❑ 35¢ fee
500 fee
rvu rurm asuu nu INWWA1.GE UOVERAGE PROVIDED— (See other side)
Nov, 1964 NOT FOR INTERNATIONAL MAIL
• '� Municipality of Anchorage s
On -Site Water and Wastewater Program
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
Parcel I.D. 050-121-15
1. GENERAL INFORMATION
Complete legal description CORONADO BLOCK 2 LOT 5
Expiration Date: i- "P
Location (site address) 17320 N_ Eagle River Loop Road Eagle River AK 99577
Current Property owner(s) JOSEPH R. MORRIS _ Day phone
Mailing address
Real Estate Agent
_11643 CELESTIAL STREET, EAGLE RIVER AK 99577
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
4
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
❑
Individual
Individual Water Storage
❑
Holding Tank
❑
Community Class A Well
❑
Community
❑
Public Water System
®
Public Sewer
❑
WaiverNariance request for:
1 '
Received by �., �� ,t •.r� r::,:� Date:
COSA to be released to the engineer, unless otheMise•requested by the engineer.
COSA Fee $ 524a, c9' Waiver Fee $
Date of Payment
Receipt Number D 5558
COSA# IJSUL((QQ,;�
Date of Payment
Receipt Number
Waiver #
6. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm ARCTERRA CONSULTING, INC. Phone 868-3791
Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577
Engineer's Printed Name KENNETH M. DUFFUS V7/14
Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition
of the well and septic applies only to the conditions as of the day tested. The Flow and absorption rates may change due to subsurface
conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate
during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are
subject to these various and dynamic characteristics and are outside the control of the -
evaluator of the well and septic system. Therefore,
ArcTerra can not give any estimate of how long a !�`�
system will function satisfactory for current or future _ OF A
occupants or can ArcTerra guarantee that no unseen r Lf IlI
encroachments, deficiencies or discrepancies exist. Ar �Q �t�
�� A0Ti�-u.1
6. DSD SIGNATURE
System #1 Approved for bedrooms.
System #2 Approved for
Disapproved.
Conditional approval for
0
bedrooms.
bedrooms, with the fo
OF
WATER AND
Original Certificate Date:
The VyrfWalit ;!5 c orage Development Services Division (DSD) issues Certificates of On-Sde Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet 10-10-12.tlx
If more than 1 septic system is on the lot:
COSA Checklist # of _
Structure served by this system _
Certificate of On -Site Systems Approval Checklist
Legal Description: CORONADO BLOCK 2 LOT 5 Parcel ID: 050.121.15
A. WELL DATA — PUBLIC WATER
Well type If A. B, or C provide PWSID # Well Log (Y/N)
Date completed Sanitary seal (Y/N) Y Wires properly protected (Y/N)
Total depth ft. Cased to ft. Casing height (above ground) in.
FROM WELL LOG AT INSPECTION
Date of test
Static water level
Well production 9.p -m. g.p.m.
WATER SAMPLE RESULTS:
Coliform colonies/100 mL Nitrate _mg/L
Arsenic: ug/L Date of sample: Collected by:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material SEPTIC I STEEL Date installed 8/2012006
Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N
Date of pumping /-g'/l/ Pumper S
C. ABSORPTION FIELD DATA
Date installed 812012006 Soil rating (g.p.d./ft2 or ft2/bdrm) 125 System type TRENCH
Length 50 ft. Width 3 ft. Gravel below pipe 5 ft.
Total depth 13.9 ft. (Measured 116/14) Eff. absorption area 500 ft2 Monitoring tube Y Depression over field N
Date of adequacy test 1/612014 Results (Pass/Fail) PASS For 4 bedrooms
Fluid depth in absorption field before test 0 in. Water added 600 gal. New depth 3 in.
Elapsed Time: 10 min. Final fluid depth 0 in. Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date
D. LIFT STATION
Date installed
"Pump on" level at in.
Datum
Size in gallons
"Pump off' level at _ in.
Cycles tested
E. SEPARATION DISTANCES - PUBLIC WATER
WELL ON LOT TO:
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
Sewer /septic service line
Animal containment areas
SEPTIC/HOLDING TANK ON LOT TO:
Manhole/Access (Y/N)
High water alarm level at
Meets alarm & circuit requirements?
On adjacent lots
On adjacent lots
Public sewer manhole/cleanout
Holding tank
Manure/animal excrete storage areas
Building foundation 5'+ Property line 51+ Absorption field 5'+
Water main 104 Water service line 101+ Surface water 1004
Wells on adjacent lots 200'+
ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main 10'+
Water Service line 101+ Surface water 1001+ Driveway, parking/vehicle storage 104
Curtain drain 50'+(NONEKNOWN) Wells on adjacent lots 200'+
F. COMMENTS
ADEC record documents attached.
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and review of
Municipal records that the above systems are in conformance with MOA
COSA guidelines in effect on this date.
Engineer's Printed Name KENNETH M. DUFFUS
Date 1/7/2014
COSA brown sheet 10-10-12.doc
in.
I
25' 25'
I
LLJ
LLjry
U)
J
QW
H U)
to
LLJ
J Z
LLJ
U
LOT 7
BLK 2
LOT 6
BLK 2
LOT 5 SEP -11C
BLK 2 YENTs
® 1 LOT 4
BLK 2
ANCHORAGE RECORDING DISTRICT
ASBUILT OF:
CORONADO SUBDIVISION
LOT 5 BLK 2 PLAT 66-34
SURVEY CERTIFICATION: I John L. Schuller have
conducted a physicalsurvey Wthis property as s�lown on this
drawing and that the improvements situated thereon are within
the property lines and no encroachments exist other than noted.
EXCLUSION NOTES:It is the owners responsibility to determine
the existence of any easements, covenants, or are
which
do not appear on the recorded subdivision plat.
RK ORDER NUMBER: "Tt SCA1E: E-Y,W
AUG 23, 2006 1'=40' kndencOak.n
06-038 : x0
JLS NW252 060
1xHYPoNR
ei
GRAVEL
D/W
�z
x�
be U
4.0' x 10.5'
Z<� N a
NLL� b o
woxg
o CG a
3 ro
1
LOT 9
BLK 2
LOT 10
BLK 2
LOT 12
BLK 2
���� oF...AZ—",X,1,
*r'?r 4 TIi r
... J .......
P .......
•.SOHN L. SCHULLER: 0
LS -10408
_a`''te!/
Z ID ENGINEERING, INC.
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907)868-3791/FAX (907)868-3793
l
LDateeceivedSTATE
OF ALASKA
DEPARTMENT OF ENVIRONMENTAL CONSERVATION
DOCUMENTATION OF CONSTRUCTION
ERAL INFORMATION
Legal Description of the Location
CORONADO S/D, BLOCK 2, LOT 5
Submitted by: (Check one)
❑ Certified Installer
❑ Approved Homeowner
® Registered En meet
Applicant Name
JOE MORRIS
Onsite Wastewater System Serves:
❑ Single Family. Number of Bedrooms
❑ Duplex. Number of Bedrooms
® Multi -Family. Number of Bedrooms 4
❑ Small Commercial Facility with Estimated
Design flow of less than 500 GPD.
Mailing Address
11643 CELESTIAL ST.
EAGLE RIVER, AK 99577
II. WATER SUPPLY SYSTEM SECTION IS OPTIONAL
Source of Water and Containment (Check all that Apply)
❑ Well (Drilled or Driven) ❑ Surface (Identify)
❑ Roof Catchment
❑ Holding Tank ❑ Other (Identify)
Type of Water System
❑ SF/Duplex
® Public
Treatment of Water (Check all that Apply)
❑ None ❑ Chlorination
❑ Filtration
❑ Other: ❑ Mineral Removal
Well Data Is the height of the well casing more than 12" above the ground? ❑ Yes ❑ No
Is a sanitary seal or well cap installed on the well casing? ❑ Yes ❑ No
Is drainage directed away from or around the casing within a radius of 10 feet of the well casing? ❑ Yes ❑ No
Is well wire enclosed in conduit? ElYes ❑ No
Date Drilled
Depth of Well (Feet)
Static water Level (Feet)
Yield (Ifavailable)
Pump Rate (Ifavailable)
Separation Distance from the Well Casio to each of the followin sources of contamination:
Septic/HoldingSeptic/Holding Tank on Lot Feet
Sewer Lines oMcasin
Abso tion Area on Lot Feet
Closest Se tic/Hold' Tank on Adjacent Lot
Closest Sewert Lot
Closest Ed e of an At,— tion Area on Adjacent Lot
Feet
FeetFeet
Indicate separation distance from toxic materials including fuel tankts
and other petroleum based materials, pesticide, fungicides or herbici:
On Lot: FeetOnAdacntLot:
Feet
Water Sam le Taken b : ame
Sampler is:
❑Buyer ❑ Engineer
Banker ❑ Government Official
Water Sample Result
Attach Co
❑ Satisfacto ❑ Unsatisfactor❑
Comments/Recommendations:
I cerci • that the above inform 'on and that provided in Section IV is correct:
Signature /
Typed/Printed Name
Kenneth M. Duffus
Title
P.E. / CE -7116
Date
111/10/06
Note: 1. Th section shou! be signed by a Certified Installer, Professional Engineer, DEC staff, or OwnerlBuilder
2. Allwater s s&ms must receive ADEC plan approval prior to construction. Se I8 AAC 80 State of Alaska Drinking Water Regulations
for specific requirements.
DISPOSAL
Type of Wastewater System:
® Septic Tank with Conventional Soil Absorption System
❑ Holding Tank: Material Type:
❑ Other— Specify Type
❑ Package Treatment Plant (requires engineered design)
Size in Gallons:
❑ Small Commercial System (<500 GPD) With Estimated Daily Wastewater Flow of:
Criteria Used to Estimate Daily Wastewater Quantity:
Manufacturer:
Gallons Per Day (GPD)
LOT 5
FNmeWSYSTEM ® REPAIR TO EXISTING SYSTEM Certified Installer Installation Notification Date:
f Installer: WALKER CONTRACTING
Date Installed: 08/20/2006
System Installed: ❑ By a Registered Engineer ® With Inspection by a Registered Engineer
❑ By Approved Homeowner attach copy of approval letter ❑ By a Certified Installer/Installer Number
Septic Tank: Material:
Manufacturer:
Size (Gallons)
Number of Compartments:
Steel
Anchorage Tank
1,250
2
Type of Soil Absorption System ® Deep Trench ❑ Shallow Trench ❑ Seepage Pit ❑ Bed
❑ Mound ❑ Other, Specify
Soil Classification: SW
Soil Rating: 125 sf / bdrm
Dimensions/Size of Absorption Area: 501 x 3'W x 5' ED / 500 sq. ft.
Gradin Size of Distribution Rock: 32 CY 0.75-3"
Thickness/Depth of Distribution Rock: 5'
Percolation Test Results, Attach Copy of Report:
Percolation Test Performed by: Kenneth M. Duffus / KND Engineering, Inc.
Minutes per Inch: VISUALS . ft. per bedroom: 125
Percolation test results must be sealedlsi&ned by a re 'stared wgmeer
List ground cover in feet over: Septic Tank: *4'+ Absorption Area: *4'+ Sewer Pipes: *4'+
Cleanout Pi s/Ca s Installed: Foundation Cleanout: Y
Se tic Tank: Y
Monitor Tubes: Y
Indicate separation distances from septic tank or absorption area, whichever is closest, to all nearby:
Public drinking water sources within 200 feet: 200'+ Private drinking water sources within 100 feet: 100'+
Nearest water bodies (see 18 AAC 72.020(b): 100'+ Lot line: 10'+
Separation Distance from On -lot Sewer Lines to Public Drinking Water Sources: 100'+ Private Sources: 25'+
Separation Distance from Bottom of Distribution Rock to Groundwater Table: 4'+ Bedrock: 6'+
Separation Distance from Absorption Area to Slope exceeding 25%: 50'+
Comments/Recommendations: Old septic was tank emptied, crushed and disposed of per code.
*Minimum ground cover with 2" insulation installed as needed(DOW Chemical Co. Styrofaom HI (Blue Board)) w/ filter fabric (Typar 3401). Other
materials: ASTM D3034 pipe, Schedule 40, and Ferneo couplings. 18"+ vertical separation maintained from waterline and sewer service line. Sewer
service line incased in 20' 6" Schedule 40 carrier pipe centered across waterline.
I certify that the above informal' and that provided in Section IV, is correct:
Typed/Printed Name
Title,RegJCert No., Inst. No.
Date
eSignatu
Kenneth M. Duffus
P.E. / CE -7116
11/10/06
ust be s ned by a Ceri edInstaller, Professional Engineer, DEC Staff, or Approved Homeowner. Ifengineering seal bearsprinted name,
n number, d, those blocks need not be com feted or en 'veered submittals.
Frank Murkowski, Governor
,��
i
NJ r-1,' uL 1 j u �
555 CORDOVA
DEPT. OF ENVIRONMENTAL CONSERVATION ANCHORAGE, AK 99501
Phone: (907)269-7519
Fax: (907) 269-3487
DIVISION OF WATER http://www.state.ak.us/dec/
WASTEWATER DISCHARGE PROGRAM
November 27, 2006
Kenneth M. Duffus, P.E.
20441 Ptarmigan Blvd.
Eagle River, Alaska 99577-8736
Re: Coronado Subdivision, Block 2, Lot 5 -Final Operational Approval for a Wastewater
Treatment and Disposal System-ADEC Plan Tracking Number 5674
Dear Mr. Duffirs:
On November 15, 2006 we received the record drawings for a 1,250 gallon two compartment
septic tank and a deep trench type onsite soil absorption system. The effective depth for the soil
absorption field is 5 feet and length is 50 feet per the approved design. A three bedroom home
with a detached one bedroom apartment are served by this wastewater system.
The Department has reviewed the record drawings finding them in conformance with the
approved construction plans for the onsite wastewater treatment system; therefore per Wastewater
Regulations 18 AAC 72.240 final operational approval is issued. The completed "Certificate to
Construct" for the wastewater system is enclosed. Please use the above plan tracking number
with any correspondence regarding this system.
This approval does not imply the granting of additional authorizations nor obligate any state,
federal or local regulatory body to grant required authorizations.
Any person who disagrees with this decision may request an adjudicatory hearing in accordance
with 18 AAC 15.195- 18 AAC 15.340 or an informal review by the Division Director in
accordance with 18 AAC 15.185. Informal review requests must be delivered to the Division
Director, 555 Cordova Street, Anchorage, Alaska 99501, within 15 days of receiving the decision.
Adjudicatory hearings requests must be delivered to the Commissioner of the Department of
Environmental Conservation, 410 Willoughby Avenue, Suite 303, P.O. Box 111800, Juneau,
Alaska 99801, within 30 days of the decision. If a hearing is not requested within 30 days, the
right to appeal is waived.
Thank you for your cooperation. If you have any questions please do not hesitate to contact me at
269-7519.
Respectfully,
William R. Rieth, P.E.
Environmental Engineer
Enclosure: As stated
cc: William Smyth, WW, w/o enc.
State of Alaska
Department of Environmental Conservation
CERTIFICATION OT CONSTRUCTION
FOR
DOMESTIC WASTEWATER SYSTEMS
Instructions:
1. Within 30 days after the construction, installation, or modification of a project is completed, the. owner, the
contractor(s) responsible for constructing the project, and aregistered engineer responsible for construction
inspection, must complete and sign this form declaring that the project was constructed in accordance with the most
recent Department -approved plans, or in accordance with the attached as -built drawings.
2. If a project is being completed in phased construction, a map shall be attached showing That portion of the project
being declared completed on the date stated in the Owner's Section. Completion. of each phase of a project must be
declared as it is completed. Additional* Certification of Construction forms are available from any Department.of
Environmental Conservation office. .
...............................................................................
Please type orprint, except forsignature: SECTION A- Owner's Section
" Name and brief description of project:
OAJ— S i rl OASTMca "E2 SySiDK .
Name of Owner: �bSEi'Ft N�stzi�i5. J� ADEC Project No.
Address: ((lOt( CELES7/At- S'1'. Date Project Completed: 1XV 1 a6041
GAG2c 2t�al �kK "
�1t7S7 t
I certify that I am the owner of the above-referencedproject. I further certify that this project was constructed in accordance
with the latest plans submitted to and approved by the Alaska Department of Environmental Conservation (ADEC), or in
accordance with the attached as -built drawings. I understand that I may be required to take remedial measures to correct any
construction which was completed without prior ADEC approval, which departs from the approved plans, and which is found
to be inconsistent with the applic requirements of ADEC wa ew ter disposal regulatio (18 72).
rl)t
nJ1�1.�1
1/i GAJ l // /1 1 1{ / fir 17l 1 i!i / .q i
(Please Sign in In I Date
f
..1
SECTION B- Contractor's Section
certify that I (or an individual under my direct supervision) have conducted an inspection of the project referenced in Section
A, or portions of the proj ect which I.had the responsibility for constructing, and that to the best of my knowledge and
information, the project, or those portions. was or were constructed in accordance with the latest plans submitted_ to and
approved by the Alaska Department of Environmental Conservation, or in accordance with the attached as -built drawings.
/.l
Name of Contractor Signatur of Contractor (please sign in.ink) Date
For multiple contractors, if applicable:
Name of Contractor Signature of Contractor (please sign in ink) Date
Name of Contractor Signakure of Contractor (please sign in nk) pate
SECTION C- Engineer's Section
I. certify that I (or any individual under my direct supervision) have conducted an inspection of the above referenced project,
and that to the best of my knowledge and information, the project was constructed in accordance with: (check one of the
following)
the latest plans submitted to and approved by the Alaska Department of Environmental Conservation
❑ in accordance with the attached as -built drawings.
Signature of Profe 'onal Engineer State of Alaska
Responsible for Construcho Professional Engineer
(Please Sign in Ink) Registration Number -
Typed or Printed Name of Professional Engineer
�t to
Date
AS -BUILT SYSTEM DETAILS/SITE PLAN
C❑R❑NAD❑ S/D, LOT 5, BLOCK 2
h �
xq
u 18M -"'COR. WALK
V / 'o f .n EL=100.0
KND H
IIFFjllll N B M
N89'S
J T00"E 185.00'
st.t' 'o
MGT op-- C14.O' 50.,
W
b r
W O C) <
i[1 z U, 75.4 _ w O =
w N L p CO <
3 CD
B 320' A SRt
'0.
FCD x
N LOT
a 2
® LOT 4
EILK 2
A—D=14.0'
FIELD BOOKS
B—D=35.8'
A—E=15.3'
102.3 102.0
B—E=29.5'
W
B—F=35.0'
d d
C—F=62.8'
�a
B—G=50.0'
o�
DDD:
NW252
ADAD FILE: 06038.dwq
C—G=35,1'
06-038
ox
c 1250 GAL
nN SEPTIC
:r w TANK
AW OF FS 11111
�* 49,TH /�_ ,A
nL1YlYGL R'111.
CE -7116
µ11134 �,$w /
�O1''ESSIONP�. ��
1250 GAL
STEEL S.T.
19'57'00"E 177.24'
1) 20'-6' CARRIER PIPE, SCH. 40.
2) 4' SEWER HAS 18" VERTICAL
SEPERATION TO WATER UNE
U Y
' cf j FINAL GRADE
FILTER FABRIC & INSULATION
50.0'
PREPARED FOR:
JOE MORRIS
11643 CELESTIAL ST.
EAGLE RIVER, AK 99577
(907)441-9117
FIELD BOOKS
CO TED:
BODNDARM
DRAWN:
kmd
STMNQ'
(NECKED:
KMD
ASBDILT_SchuIIer/KND
DALE:
11/10/C
OM FILE:
DDD:
NW252
ADAD FILE: 06038.dwq
ve Ne"
06-038
ADEC Permit : 5674
Io
z
LoT 11
K 2
.n
a
p
0
z 0 40
1GRAPHICS SCALE
LOT 12
6LK 2
8 O
ABBREVIATIONS
BOH = BOTTOM OF TESTHOLE
CO = CLEANOUT
MT = MONITORING TUBE
FCO = FOUNDATION CLEANOUT
lEl l) ENGINEERING, INC.
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907)896-5lll/FAX (907)098-8111
..XNDEngLneering.e m/knAengOak.net
0.5'
5.0'
—L
BOH
74.8
SCALE:
NTS
4•T c,Ku QMNID.M
S+ and AM
ABBREVIATIONS
BOH = BOTTOM OF TESTHOLE
CO = CLEANOUT
MT = MONITORING TUBE
FCO = FOUNDATION CLEANOUT
lEl l) ENGINEERING, INC.
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907)896-5lll/FAX (907)098-8111
..XNDEngLneering.e m/knAengOak.net