Loading...
HomeMy WebLinkAboutCORONADO BLK 3 LT 2o ron O_CI 0 S.D. L GRE'"':'-' ANCHORAGE AREA B0r ~ Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 H NAME INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LEGAL DESCRIPTION LOCATION SEPTIC TANK: DISTANCE FROM WELL MANUFACTURER MATERIAL~.~(-~ NUMBER OF COMPARTMENTS INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH_ .LIQUID CAPACITY '~OO~) GALLONS. SEEPAGE PIT: NUMBER OF PITS LINING MATERIAL BUILDING FOUNDATION ~"0.~~, ADDITIONAL ABSORPTION DIAMETER11-3 ORWIDTH__, LENGTH , DEPTH CRIB SIZE: DIAMETER'S,-/ DEPTH Gl DISTANCE FROM: WELL NEAREST LOT LINE ~'1 TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~)~D SQ. FT. WELL: ~ TYPE ~ l~1,{ BUILDING FOUNDATION CESSPOOL APPROVED CONSTRUCTION NEAREST , LOT LINE , OTHER SOURCES DISAPPROVED DEPTH DISTANCE FROM: NEAREST SEPTIC SEEPAGE , SEWER LINE , TANK __, SYSTEM REMARKS DISTANCES: DIAGRAM OF SYSTEM INSTALLED BY: PIPE MATERIAL: LOT SLOPE: REMARKS: Form No. EO-031 DATE ' G.A.A.B. GREATER ANCHORAGE AREa BOROUgh DEPARTMENT Of ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PERMIT NO. NAME OF APPLICANT INSTALLATION LOCATION INSTALLATION OF: SEPTIC TANK 'I ~ SEEPAGE PIT ~ , DRAIN/~IELD _ _ / ,' , , / OTHER NOTE:: THIS P£RMIT IS NOT VALID WITHOUT SOIL TE:ST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCES, REQUIREMENTS DIAGRAM OF SYSTEM FOUNDATION TO SEPTIC TANK ~ ~' CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF / FOUNDATION TO seePAGE PIT ~"~U , DRAIN FIELD LICENSED DESIGNER SEPTIC TANK , SEEPAGE PIT ~--~'~ ., DRAIN FIELD TO NEAREST LOT LINE. ~..~~ WELL TO SEPT,C TAN "" ,f . SEEPAGE P T DRAIN FIELD ALSO CONSIDER AREA WELLS. w~. m~N ~O s~P~lC t~N~ /~ S~.~ Pit DRAIN FIELD SEPTIC TANK, /~ , SEEPAGE PIT F~0 DRAIN FIELD /O~ TO RIVER, LAKE, STREAM. EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. FORM NO. EQ-016 ~[ECEIVED "0~ l~$1 t~ ~orth a ghou~and opinion~' Performed For -Mr Halverson Date Performed June 17 197J~ Leaal ~escrintion: Lot 2 Block ~ Subdivision 0o~o~o This form Renorts Soils Loo ~s Percolation Test .nenth Feet Soil Characteristics 1 3 5 7 .... Reddish silt & organics__ Slightly damp Well graded gravel (G.W.) '85 S.F./B.R. Bottom of test hole 1~' Was Ground Water Encountered? I¢ Yes, At wha. t Denth? No ! j ,, IReadinq Date Gross Time Net Time Depth to H20 Net Dron I t '' Percolation Rate Minute Proposed Installation: Seenaoe Pit Yes Drain Field Deoth of Inlet Denth To Bottom Of Pit Or Trench CoM!~ENTS: No groundwater or bedrock encountered . Test Performed By N~a~ Haus am Data Certified BY:oo~%struction Test Lab Da t e: June I 7 1974_