Loading...
HomeMy WebLinkAboutCOTTONWOOD HEIGHTS BLK 1 LT 14 o t t onwooc ts. i_ iL 051 Municipality of Anchorage Community Development Department Page 1 of 3 On-Site Water&Wastewater Program 4700 Elmore St. •P.O. Box 196650 Anchorage,AK 99519-6650•http://www.muni.org/onsite•(907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181412 PID Number. 051-431-30 ❑ New ■Upgrade Name: ABSORPTION FIELD MARK& BETTY WARREN Address: ❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound 20144 LAUGHLIN STREET, CHUGIAK,AK 99567 ❑ Other Soil Rating: Total Depth from original grade: Phone: No.of Bedrooms: (813) 917-1415 4 GPDISq.Ft. Ft. Depth to pipe invert from original grade Gravel depth beneath pipe LEGAL DESCRIPTION FL Ft Subdivision: Block: Lot: Fill added above original grade: Grave gth COTTONWOOD HEIGHTS 1 14 Ft. Township: Range: Section: Graval Width: \ Beds Number of lines: Distance between lines: Ft Ft. SEPARATION DISTANCES Total absorption Number of trenches: Dist.between trenches: To Septic Absorption Lift Holding Public/Private From Tank Field Station Tank Sewer Lines SQ.Ft. Ft. Well 100'+ - - 25'+ TANK I Septic ElS.T.E.P. :Holding El Other Manufacturer. Capacity. Surface Water 100'+ 0 - - ANCHORAGE TANK 125017. Gal. U) Material: Number of compartments: Lot Line 5'+ w - - N/A I STEEL 2 Foundation 10'+ - - LIFT STATION Curtain Drain - NONE KNOWN Manufacturer: C.. I Gal. Remarks: 'Pump on level at 'Pump off level at High water alarm at: Pump Make 8 Model Electrical Inspections performed by: PIPE MATERIAL 03034 D3034 House to tank (FOR NEW) Tank to (FOR NEW) drainfield Installer D3034 JR'S EXCAVATING Drainfield EXISTING CO/MT (FOR NEW) Inspector GEG, Ltd. BENCH MARK (Assumed elevation) Inspection 100.00 Ft Dates: 1st 11/27/2018 2nd Location and Dosc p on 3rd - 4th - BOTTOM OF WINDOW SILL NEAR POINT"A" ENGINEER'S SEAL Community Development Department Approval ��.�` �'1114t/ Conditional approval: Date: :*• • — *.j• i 9''` /\ I' •o- • ; c • ♦ c^';• r--'e, kGam ,s:'�� "1 J, •1 CE-79 ' _4 �j I C. t 43,.•4. Z. Approved: lam-��— Date: l.21 -f g �.deo p:.••....1... ` P.4: PERMIT NUMBER: PARCEL ID NUMBER: \ OSP181412 RECORD DRAWING 051-431-30 4. .... .:4. LAUGHLIN STREET A B DBL1 14.4 25.0 DBL2 15.3 25.4 ST1 16.4 26.2 ST2 23.8 31.5 DBL3 25.4 32.7 1• DBL4 26.9 33.9 EXISTING , • • + EXISTING CO1 30.8 37.1 CAR •'.': •*' GARAGE CANOPY .1• . ..r....:' .• .' • . .'•.. • HED 8'LOT LINE WAIVER GRANTED t "' ••, •.- ' +''' /// EXISTING DRAINFIELD. SUMP.. •' •?• ••'•`'. . %...• N PASSED SEPTIC ADEQUACY — TEST ON 11/5/2018 — INSTALLED DOUBLE -Co1 . SCALE: CLEANOUTS(DBL3&DBL4) •°' .` ' —"ST2 �, 1"=40' NEW 1250 GALLON " ....' •. STEEL SEPTIC TANK -ST1 = 'i ' INSTALLED DOUBLE "' _ CLEANOUTS(DBL1&DBL2) ••';-'•. NOTE:THE OLD SEPTIC TANK jIIIII/I •,, WAS COMPLETELY REMOVED AND DISPOSED OFF SITE PER THE M . CONTRACTOR.THE NEW TANK LOT 13,BLOCK 1 j 8 o :.'• !OTTONWOOD HEIGHTS S/D j n *' WAS INSTALLED IN THE SAME C j..o a o F- _ LOCATION AS THE OLD TANK. y- rr) O •/ W♦ \♦ i/// Z �// \� \\ to H NOTE:THE WELL ON LOT ?U \ �\ 13 WAS PHYSICALLY iQ O • • •• FOUND AND THE 100 FOOT ict w \� SEPARATION DISTANCE -- WAS VERIFIED PRIOR TO // �• •\ THE INSTALLATION OF o xCJ 1 NEW SEPTIC TANK 11 �p�Jy 0_ a 11 ���� `1 I 11 4 1 I 1 1 I I 1 EXISTING WELL i EXISTING WELL 1 1 1 W 1 1 1 1 1 ..*AMU%,II 1 :,.4.1..`� �F .A/ .,111 GARNESS ENGINEERING GROUP, Ltd ENGINEERING SALES CONSULTING 0 0 3701 E.TUDOR ROAD,SUITE 101'ANCHORAGE,AK 99507'PHONE(907)337-6179'FAX(9071338-3246'WEBSITE:www.gamessenglneedng.com • ' • PREPARED FOR: PHONE NUMBER: PAGE NUMBER: V.%...• •ey G..'-ss t / MARK WARREN (813)917-1415 2 OF 3 �• it t� CE-79 3 0�_�/ PROJECT/LEGAL DESCRIPTION: DRAWN BY: •v♦��n•. I S 0.•.<�:� COTTONWOOD HEIGHTS S/D; BLOCK 1, LOT 14 J.L.M. Ir'Z .ge-`• • .;4') • TYPE OF WORK: DATE 111 ";I `S`; , LICENSERECORD DRAWING OF SEPTIC TANK UPGRADE 11/28/2018 #AECC8'.4 1� J (PERMIT NUMBER: PARCEL ID NUMBER: \ OSP181412 RECORD DRAWING 051-431-30 FINAL GRADE =97.07-97.76 ST1 ST2 TOP OF TANK TOP OF TANK AT INLET=93.04AT OUTLET=93.04 n t 1— NEW NEW 1250 GALLON INVERT OF BUNG SEPTIC TANK AT INLET=92.37 (RATED FOR INVERT OF BUNG 10' BURIAL) AT OUTLET= 92.25 .<4\;:,C-......6..."....... 11F GARNESS ENGINEERING GROUP, Ltd';*4 ENGINEERING SALES CONSULTING I 0 0 3701 E.TUDOR ROAD,SUITE 101•ANCHORAGE,AK 99507•PHONE(907)337-6179'FAX(907)338-3246'WEBSITE:www.gamessengineenng.com r PREPARED FOR: PHONE NUMBER: PAGE NUMBER: !. ' ,••'zI i �G re a ess Sg7= MARK WARREN (813)917-1415 3 OF 3 °06 ' / C17-79/5 0 �� PROJECT/LEGAL DESCRIPTION: DRAWN BY: ♦•A •�� s (( :t 47 COTTONWOOD HEIGHTS S/D; BLOCK 1, LOT 14 J.L.M. yi �0.••'"•• ...�•............( e,• TYPE OF WORK: DATE: LICENSE i�OFES *' RECORD DRAWING OF SEPTIC TANK UPGRADE 11/28/2018 #AECC884 , ����� } 711 1C,PAify MUNICIPALITY OF ANCHORAGE On-Site Water&Wastewater Program PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http:/lwww.muni.org/onsite I) pay tni nt On-Site Wastewater Disposal System Permit Permit Number: OSP181412 Effective Date: 11/15/2018 Work Type: SepticTank Upgrade Expiration Date: 11/15/2019 Tax Code Number: 05143130000 Site Legal Address: COTTONWOOD HEIGHTS BLK 1 LT 14 G:0756 Site Mailing Address: 20144 LAUGHLIN ST, Chugiak Owner: WARREN MARK J & BETTY Lot Size in Sq Ft: 54945 Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 4 This permit is for the construction of: ❑ Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Date: / /— Issued By: %,L Date: //,�� • Municipality ®f Anchorage �z ; _ur-. P.O. Box 196650 s 4700 Elmore Road Anchorage, Alaska 99519-6650 s (907) 343-7904 0 Fax (907) 343-7997 http://www.muni.orq/Onsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV181094 COSA#: Permit#: OSP181412 PID#: 051-431-30 Legal Description: Cottonwood Heights B1 L14 Engineer: Garness Engineering Group Applicant: Mark Warren Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 8.0 feet. This waiver approval applies to the existing absorption field only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. 1 Waiver is Granted: X Waiver is not Granted: Date:l/O/7/ 0 Approved by: 1G,-iZar Name of Reviewer **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department ' " Phone: 907-343-7904 Development Services Fax: 907- 343-7997 On-Site Water & Wastewater Program Mayor Dan Sullivan an-Site SeWi er/Well Permit Application For A Sin6e Family Dwelling Parcel I.D,: 051 "q31-a0 Property bwner(s) MARK WARRE Day phone (813)917-1415 Mailing address P:O.BOX 62, SLEETMUTE,AK 99668 Site address 20144 LAUGHLIN STREET, CHUGIAK,AK 99567 Legal description (Sub'd, Block& Lot ) COTTONWOOD HEIGHTS;BLOCK 1, LOT 14 Legal description (Township, Section & Range) Lot Size Sq.Ft. Number of Bedrooms 3-SEPTIC SYSTEM SIZED FOR 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: (®au that apply) Initial Single Family(SF) Absorption Field ❑ (w/wo ADU) Septic Tank ® Upgrade Duplex (D) I Renewal ❑ Holding Tank ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: LOT LINE TO DRAINFIELD Distance: 8 FEET I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: 2 16" Waiver Fees: of I 5 Date of Payment: 1(1(3 [13 Date of Payment: I03/a Receipt Number: 0Y6/3136 Receipt Number: CY39 3 Permit No. SPI gIL/la. Waiver No. 05 v/ aIORV' (Rev.01/11) GARNESS ENGINEERING GROUP, Ltd ENGINEERING SALES CONSULTING November 12, 2018 Municipality of Anchorage Development Services On-Site Water & Wastewater Program 4700 Elmore Roade Anchorage, Alaska 99507 Phone: (907) 343-7904 Reference: Septic Tank Upgrade for Cottonwood Heights S/D; Block 1, Lot 14 To whom it may concern: The 3 bedroom house on the referenced property is served by a private well and septic system. Per MOA records, the septic system serving the subject property was installed in 9/2/1985 and was sized for 4 bedrooms. The septic system consists of a 1250 gallon steel septic tank and a deep trench type drainfield (56 feet long x 3 feet wide with 7 feet of effective). The drainfield has recently passed a septic adequacy test, however the septic tank is over 33 years old. Instead of trying to verify the integrity of the old septic tank, the new owners would like to upgrade the septic tank. We are proposing that a new 1530 gallon, 2-compartment Infiltrator plastic septic tank be installed, and the old septic tank permanently decommissioned. We request a septic tank upgrade permit be issued. It has also come to our attention that the existing sump is approximately 9.5 from the west lot line per the Bell & Associates survey. We are requesting a 8 foot lot line waiver from the west lot line to the drainfield as part of this permit request. We are unaware of any adverse effects this would have on the adjacent property. Please do not hesitate to call us at 337-6179 if you require further information. Thank you for your assistance. Since ely, Je ye A G:rn--s, P.=., M.S. Presid n 3701 East Tudor Road,Suite 101 *Anchorage,Alaska 99507-1259 Phone: (907)337-6179*Fax: (907)338-3246 Website: www.garnessengineering.com ii I 1 I LOT 2,FERGUSON S/D ( LOT 1,FERGUSON S/D I TRACT A,WITMAN S/D I (NO ENCROACHMENT CONCERNS) I (NO ENCROACHMENT CONCERNS) I FOREST PARK TRAILER COURT I • •::,..L:.:1,:. LAUGHLIN STREET -f:':%:, 1:.•*..):�' EXISTING GEG.Ltd.HAS AN 8 PAGE SPECIFICATION LETTER EXISTING THAT PERTAINS TO THIS DESIGN. Y PROCEEDING CAR CANOPY r:;: GARAGE FORWARD WITH THIS INSTAL TION,THE ENGINEER,WELL DRILLER,CO RACTOR AND -".-'e' PROPERTY OWNER AGREE T THEY HAVE • •� : r .'••, '`�. READ THESE SPECIFICATIONS 0 AGREE TO "'`;"'.'w- .':•. ...':". SHED ACCEPT THE TERMS AND CONDI NS OUTLINED. 8'LOT LINE WAIVER REQUESTED 0— '; i ''1•' ! ',,;; \' N EXISTING DRAINFIELD.PASSED SEPTIC ADEQUACY TEST ON 11/5/2018 ;•:4-',,,:i.....',,;Y : •: •:: /INSTALL DOUBLE• S ALE: EXISTING 1250 GALLON SEPTIC TANK ;; ./ CLEANOUTS TO BE DECOMMISSIONED PER UPC �I D ' :;�•.;: 1"=60' - D PROPOSED 1530 GALLON INSTALL FOUNDATION CLEANOUT • FCO ':i., 2-COMPARTMENT INFILTRATOR SEPTIC TANK LOT 13,BLOCK 1 `.Z•''•,• COTTONWOOD HEIGHTS S/D _ •," LOT 15,BLOCK 1 Oji: ., COTTONWOOD HEIGHTS S/D / :••.:-:•••••1' (NO ENCROACHMENT CONCERNS) NOTE:WELL IS TO BE / \ PHYSICALLY FOUND ON \ // / \ LOT 13,AND THE 100 FOOT /• L} \\ SEPARATION DISTANCE / \ EXISTING 3 \ i VERIFIED PRIOR TO 2/ INSTALLATION OF NEW Jy�O/ \ BEDROOM HOUSE SEPTIC TANK A / \ (SEPTIC SYSTEM \ n SIZED FOR 4 �v`� % \" \r BEDROOMS) _ta�� \ "§-44/ /% // ^a'p-\ / \1 01 1 / //j I / / ' EXISTyJG WELL 1 /' // " p0• 0 EXISTING WELL , I / / v \\ / / �' // % .`'.,t9 \ / / / �' &O ----,/------107-U ;--------------------- ---4------•--------J O \\�� 10 UTILITY EASEMENT / it- / " / Op4' � LOT 19,BLOK 1 �� L0112,BLOCK1 \ ----�—�/ //LOT 11, I COTTONWOOD HEICGHTSS/D \\� `__ ——_�C9•1ONWOOD HEIGHTS S/D / BLOCK 1; '13 i (NO ENCROACHMENT CONCERNS) / COTTONWOO / HEIGHTS S/DI I ***1111\ OF 7rgtm•zgpmnagionsmazaddirlialli . ...;. .,,, P�•''''''..... ••••• •• .'V �• GARNESS ENGINEERING GROUP, Ltdif ENGINEERING•SALES•CONSULTING , 3701 E TUDOR ROAD.SUITE 101•ANCHORAGE.AK 99507•PHONE(907)337-6179•FAX(907)338-3246•WEBSITE:www.gamessenginsaring.com ..Q•.. • 1 ,Illti • 1E.a PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0 f^• - •y A. =SS 'Lid/ MARK WARREN (813)917-1415 1 OF 1 �•. , :.1• C 79 PROJECT/LEGAL DESCRIPTION: DRAWN BY: •� • • 4 COTTONWOOD HEIGHTS S/D; BLOCK 1, LOT 14 J.L.M. •• I OF,,. ESS• P\, 40 TYPE OF WORK: DATE: LICENSE,1,,'\���_"••• SITE PLAN FOR SEPTIC TANK UPGRADE 11/13/2018 #AECC884 25 0 50 bed II GRAPHIC SCALE 1" = 50' — — - LAUGHLIN STREET 4- BASIS OF BEARINGS • LEGEND s89.59.38-Em(R) ro 0 184.94'(M) 185.00(R) � 0_ 0FOUND REBAR GARAGE ON 19.4' @ SEPTIC VENT CONCRETE FOUNDATION LUMBER CLEAN OUT LUMA - co RETAINING WALL d ?so. , li 50.8' G WELL 41[1 _. SEE A GAS METER NOTE 2 20'X13' / A ELECTRIC METER CAR CANOPY ' ' 0 (SEE NOTE 3): • 0 UTILITY POST s v STAIRS GUY WIRE (TYP) 0 0 0 (R) (R) RECORD PER PLAT 71-291 N N LANDSCAPING (M) MEASURED 3 3 \4 i% . ‘•• LOT 14 (C) COMPUTED - o \�\ ....::...;• 54,874 S.F.(M) m re o =... o/",, OVERHEAD UTILITY 0 0 N .. 1.26 AC.(R)(C) ..:1- o zo z I cdrn ROOF OVERHANG N N 4.6'X7.0' ENCLOSED GRAVEL DRIVEWAY f 43.3' ,as o' ENTRY PORCH 3 0 \ \\\ N o \\ .. WOOD DECK 1-STORY BI-LEVEL HOUSE o o .4� CONCRETE PAD ON CONCRETE FOUNDATION z z • 8'X8' GREENHOUSE NOT ON FOUNDATION 132.7' PLAYGROUND NOTES G 1. EASEMENTS OF RECORD, OTHER P THAN THOSE SHOWN ON THE RECORDED PLAT, ARE NOT 1 SHOWN HEREON. Q SEE NOTE 4 • 2. 14.7' X 10.6' STORAGE SHED rj LOT 15 NOT ON FOUNDATION. SITS ON O 10' UTILITY EASEMENT CONCRETE BLOCKS. 0 w S89'49�18MW 184.95'(C) OT 12 3. PER CLIENT, CAR CANOPY IS Q S89'59 38 E 185.001(R) LOT 19 TO BE MOVED DURING SUMMER OF 2019. °o 0 /LOT 11 0 4. REBAR FOUND IN BAD CONDITION. HELD RECORD. ti-.,;%...••‘..\\..‘ / 00 • %• it'.•• '� '. l� �;'147-,...49TH i 9t >••• •• (THIS DRAWING REPRESENTS A MORTGAGE LOCATION SURVEY PREPARED IN ACCORDANCE WITH THE ASPLS MORTGAGE LOCATION SURVEY STANDARDS. ff THIS MORTGAGE LOCATION (AS-BUILT) SURVEY IS A REPRESENTATION OF THE t �c FRANK R. BELL . o/� CONDITIONS THAT WERE FOUND AT THE TIME THE LOCATION SURVEY WAS i!I-'4,.'•..Nov.09,2018..••. 3252-S ••p•,../ TOORANRMED INACCURACIES DOES NOTHAT A STITUTE A SUBSEQUENT BOUDARY NDARYUSUVEY RVEY MAY Y DISCLOSE.IS BJECT 1F5 ``\�pA0ffSS I ONAI r INFORMATION CONTAINED HEREON SHALL NOT BE USED TO ESTABLISH ANY FENCE, \�`"`l� STRUCTURE, OR OTHER IMPROVEMENTS UNLESS GROSS NEGLIGENCE IS DISCOVERED, THE LIABILITY EXTENT OF THE I HEREBY CERTIFY THAT AN PREPARER SHALL BE LIMITED TO THE AMOUNT OF FEES COLLECTED FOR SERVICES ACCURATE SURVEY OF THE IN PREPARATION OF THIS PRODUCT. FOLLOWING DESCRIBED PROPERTY; COTTONWOOD HEIGHTS SUBDIVISION engineers L14 61 COTTONWOOD HEIGHTS SUBDIVISION BLOCK 1 LOT 14 surveyors AS-BUILT SURVEY WAS MADE ON NOVEMBER 06, 2018 PREPARED FOR: AND THAT THE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY SHANE DENNY LINES AND DO NOT OVERLAP OR DRAWN BY: WEM FLD BK: ENCROACH ON THE PROPERTY LYING CHECKED BY: VFS FRBA18-03 ADJACENT TO THE PREMISES IN QUESTION AND THAT THERE ARE NO 801 W. FIREWEED LN. #201 JOB NO.: 2018-2577 MOA GRID: NW 0756 ROADWAYS, TRANSMISSION LINES OR ANCHORAGE, AK 99503 OTHER VISIBLE EASEMENTS ON SAID I (907)274-5257 SCALE: AS SHOWN DATE: 11/09/2018 `PROPERTY EXCEPT AS INDICATED HEREON. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME HONEI MAILING ADDRESS ]Well: ~:~ 1:::::::~, ,)1- I Absorption~:~ar¥ Dwellii~,,~ ! I Material I F Inside length ~ Width HOMEMADE: etl~-nng ~ LEGAL DESCRIPTION LOCATION DISTANCE TO: mo-,~l-Z~ I- v Manufacturer ~ Liq. ~acty ngalons Well DISTANCE TO: Manufacturer DISTANCE TO: IlWell ~ ¢~2:> ~ ~ No. Length oflea h lin.e ~ F ou ndatj.on ~ Material Nearest lot lin~L' NO. OF BEDROOMS PERMIT NO. No. of comp~.~.ents Top of tile to finish grade [] NEW [~fJJ PG RAD E Liquid depth PERMIT NO. Liquid capacity in gallons PERMIT Total le~q.~o~ tlj..~ Trench wi~.~,inches Distance be. tw~r~t ~ lines Material beneath tile ~.~ *¢~ inches Total effective absorDJ[[on Length Type of crib DISTANCE TO: DISTANCE TO: Width ;rib diameter Depth [~(ib depth PERMIT NO. Total effective absorption area Well Building foundation Nearest lot line Driller Distance to lot line PERMIT NO. foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS SOIL TEST RATING INSTALLER REMARKS J APPROVED ~ .. ~ DATE 8:RB 196 ~H. 694-~979 72-013 (Rev. 3/78) DEPAF(TMENT OF HEAL.]'H AND ENVIRONMENTAL. PROTE[.3TION 82.:'.5 L. STREET, ANCHORAGE., AK 99501 264-4720 (]N--"'S I "FE~- SEWER F'ERM I ]' PERM I'T' N[): I)ATI'~: ISSUED: 850554 08/3(}/85 APPL I CANT ADDRESS: CONTACT PHONE: CCC CONST. % S&S ENGINEERING EAGLE RIVER, AK 99577 694-2979 LEGAL. DESCRIP: SUBDIVISION: COTTONWOOD HT8. LOT: 14 BLOCK: 1 SECTION: 29 TOWNSHIP: I5N RANGE: 1W L, DT SI~ZE: 1..-~SA (SQ, F'T'. OR ACRES) MAX BEDROOMS: 4 Listed below are the options available to you in designing your septic system. Choose the option that best ~its your site. DEPTH TO PIPE BO'T'TDM (FT.) GRAVEL 'DEPTH (F'¥.) TOTAl,.. DEPTH (FT. ) GRAVEl,.. WIDTH (FT.) GRAVEL LENGTH (FT. ) GRAVEL.. VOLUME ((.",L~. YDS. ) 'T'ANK SIZE (GALS) SOIL RATING (SQ.FT, /BR) TRENCH BE-_-D W . DF~:A I N 4.0 4.5 4.0 7.0 0.5 3.5 11,0 5.0 7.5 ~.5 ~0.0 5.0 36.0 38, 0 54.0 2!5, 0 .28.2 4.0.0 1,250.0 ** 1,~-~50.0 ** 1.,250.0 ** 1~.5 125 1~5 'TANK MUST HAVE AT LEAST TWD COMPARTMENTS I c:er'tiEy that: 1. I am .~'amilzar with the requirements ~or on-site sewers and wells as; set. £orth by the Municipa(lity oE Anchorage (MOA) and the ~tate oF Alaska. 2. I will install the system in accordance with all MOA codes and regulations, and in compliance with the design criteria o~ this permit. 3. I will adhere to all MOA and State' of Alaska requirements ~or the set. back distances ~'rom any existing well, wastewater disposal system or public sewerage system on this or any adjacent, or nearby lot. 4. I understand that this permit is valid ~or a maximum oF 4 bedrooms and any enlargement, will require an additional permit. IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUlL, DING CODES, THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUIL. TS WIL. L NGT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (.3) THE ELECTRICAL WORK MUS'F BE DONE BY A LICENSED ELECTRICIAN. SIGNED ~~_~__~~ DATE: ..... ~~.~__..~ .... AF:'PL. I (JAN'1': [~]N~I"~ ' / ~ ~ PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST DA'~I~ PERF~ LEGAL DESCRIPTION: L..- 8 9 10 11 12 13 14 "-' '~15 16 17 18 19 20 1 2 3 4 5 6 7 Township, Range, Section: 'T"F-i~'O' ~ SLOPE WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT f~"' ~) DEPTH? p E Depth t0 Water After Monitoring? Date: Gross Net Depth to Net Reading Date Time Time Water Drop I PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN, BETWEEN __ FT AND __ FT COMMENTS ". PERFORMED B~' ~t~' ~'1~ ~ '~ ~ ~~ CERTIFY THAT TH~ TEST W~S PERFORMED IN ACCORDANCE'WITH AL~CiPAL GUIDELIN~ I~ EFFECT ON THIS DATE. DATE: 72-008 (Rev, 4/85) GRE"ER ANCHORAGE AREA BOr'"UGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE FROM WELL /~7' INSIDE LENGTH MANUFACTURER 5/~b/C ~/~.~t... MATERIAL INSIDE WIDTH LIQUID DEPTH_ NUMBER OF COMPARTMENTS '2...- , .LIQUID CAPACITY /~ GALLONS. SEEPAGE PIT: NUMBER OF PITS / ~ ! DIAMETER ~//~ OR WIDTH LENGTH , DEPTH LINING MATERIAL Z~ BUILDING FOUNDATION ~'~ ~' CRIB SIZE: DIAMETER ~__~___DEPTH ~ DISTANCE FROM: WELL TOTAL EFFECTIVE NEAREST LOT LINE_ ABSORPTION AREA (WALL AREA) --~)¢/ SQ. FT. ADDITIONAL ABSORPTION WELL: BUILDING FOUNDATION __ CESSPOOL APPROVED CONSTRUCTION NEAREST ,.~1' NEAREST , LOT LINE , SEWER LINE , OTHER SOURCES DISAPPROVED REMARKS DEPTH DISTANCE FROM: SEPTIC /~7~ SEEPAGE /~-~ , TANK , SYSTEM DIAGRAM Of SYSTEM INSTALLED BY: PIPE MATERIAL: LOT SLOPE: REMARKS: Form No. LQ-031 // G.A.A.B. GREATEr ANCHORAGE ArEa BOROUgh DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 PERMIT NO. SEWAGE DISPOSAL SYSTEM- APPMGATION AND PERMI~///~/~.?~ INSTALLATION LOCATION INSTALLATION OF: SEPTIC TANK ~ SEEPAGE PIT ~ , DRAIN FIELD ./2 FINANCED THROUGH SOIL TEST RESULTS OTHER c~7~~ /S''~')'~OTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. TYPE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT ~.~.'~--~ f , DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK ~C--/i , SEEPAGE PIT TO NEAREST LOT LINE. WELL TO SEPTIC TANK DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD SEPTIC TANK, //~O'~, SEEPAGE PIT TO RIVER, LAKE STREAM, DRAIN FIELD SEEPAGE PIT ALSO CONSIDER AREA WELLS. SEEPAGE PIT CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit FITTED WITH AIRTIGHT REMOVABLE CAPS. DIAGRAM OF SYSTEM GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. SED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. /~ ~ FORM NO. EQ-01 6 GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" Street ANCHORAGE, ALASKA 99503 Case # Performed For ~---c~/. ~'mt-oor,,0 P_. Dated Performed_ .~.//2"/~ ~ Legal Description: Lot r__L_q___Block ! Subdivision [o?~-o~cooo~ This Form Reports Soils Log ? Percolation Test__ - Soil Test Must Be Logged To 4' Below Proposed Seepage System - Depth Feet Soil Characteristics 2w 10w 11-- 12-- 13-- I I Was Ground Water Encountered? If Yes, At What Depth? Itc) -'iI Reading Date Gross Time Net Ti me Depth to H20 Net Drop Percolation Rate Minute Proposed Installation: Seepage Pit Drain Field Depth of Inlet Depth to Bottom of Pit or Trenc~ COMMENTS: Date Certified BY: Date: APPLIC'~NT FILLS OUT UPPER HA' ' ONLy Prop,rty Owner .~.~?ri~..~-~. ¥ ~~~ ~~'~ Phone Buyer Malling'Addre. ~, t~W~¢ ~ F~ _ . i , . . . , / . ~ . Address ' ' ' ~ ~ Phone Realty Co. & A~nt -~ Zip Code Address Type of Resi~nce ~Slngle Family ~ Multiple Family No. of Bedrooms ~ Other Water Supply / 7~ ~ndtvi~ual A~ACH WELL LOG, A w~l log is required for all wells drilled since June 1975. ~-~ Cemmunity For wells drilled prior to that date, give well depth (attach log if available). ~ Public Utility Sewer Disposal ~dividual Year Individual Installed: ~.~;~ ' ~ P~blic Utility When Connected to Public Utility: ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE.EST BEFORE ~OCESSING CAN BE INITIATED, Time ~ Time [ Time Time Date Date Date Dataval ~ Inspector Inspector Inspector Inspector Field Notes: ~.~. ~.... ~. /.~;I APPBOVED BEDROOMS 'CONDiTiONS OF APPROVAL ( )DISAPPROVED ( ) CONDITIONAL APPROVAL* • � ' Municipality of Anchorage ` a° • _ On-Site Water&Wastewater Program 4'o ;, 2 \ (907)343-7904 8 9 S E T Y cr � s 4 -1,3 .. CERTIFICATE OF ON—SITE SYSTEMS A"- O AL. ` '' Da - ti • I -J 91 Parcel I.D. 051-431-30 Expiration -...rt- 1 �isai.— 1. GENERAL INFORMATION Complete legal description COTTONWOOD HEIGHTS SID;BLOCK 1, LOT 14 Location (site address) 20144 LAUGHLIN STREET, CHUGIAK,AK 99567 Current Property owner(s) MARK&BETTY WARREN Day phone (813) 917-1415 Mailing address P.O. BOX 62,SLEETMUTE,AK 99668 Real Estate Agent Day phone 2. TYPE OF DWELLING: II Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 (HOUSE IS CURRENTLY ONLY 3 BEDROOMS) 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well I Individual On-site II Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ WaiverNartance request for N/A Distance: - Received by: /4 Date: /z/40 F COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee$ 520 Waiver Fee$ Date of Payment t g-!anf it Date of Payment Receipt Number 065 Receipt Number COSA# (Y)U 7IIPCN Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are)safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and.State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP,Ltd. Phone 337-6179 Address 3701 E.TUDOR ROAD, SUITE 101 *ANCHORAGE,AK,99507 ,,// g JEFFREY A. GARNESS, P.E. I Z 1 J '� 4.7 7 Engineer's Printed Name Date Engineer's Comments: In conducting this evaluation,GEG provided an engineering evaluation of the well and/or septic system in accordance with the ���iiki\\%..1 guidelines and regulations established by the Municipality of Anchorage and industry practices.The reported results describe the .44.. OF *4, condition of the system's on the date/s of the evaluation.Separation distances were measured to readily identifiable features. �� .\�`,.•••••• h. Hidden defects or encroachments may exist that were not identified during the evaluation.The operational fife of all wells and septic q .♦ systems depend on a variety of variables including,but not limited to,soil conditions,groundwater levels(that may fluctuate during • `) • the year),quality of construction(materials and worlonanship),and the water usage of the family utilizing the system's.These fit *; A I. i\ * t conditions can vary,and are outside the control of GEG.Satisfactory test results do not guarantee future performance of the ■ . 1 systems;therefore,GEG makes no warranty(express or implied)regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the %. ,,?` . •, ,,,, M. ,,,,,, ,� current systems fait.The content of this report is for the sole benefit of the person/party who retained GEG.Reliance upon the e . Ga ss : W I information provided in this report by any other person or party,including but not limited to subsequent properly purchasers,is not ♦ % 11 1 ,_' authorized.In short,GEG disavows any legal duty to anyone other than the person/party who paid for this report. �• f�.,p / CE-79 3 c\so 6. DSD SIGNATURE LICENSE/11fa�OFES �. 01 le{ #AECC884 \\sss. Y System#1 Approved for bedrooms. System#2 Approved for bedrooms. • Disapproved. , Conditional approval for bedrooms, with the following stip4tionsn-SITE ^(I -- WATER AND .1` WASTEWATER c, 1-1 PROGRAM U By` `, �,` Original Certificate Date: (7-- Zl H 8 The Municipality or Anchorage Develop,emt Services Division(DSD)issues Certificates of On-Site Systems Approval(COSA)based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: . COSA Checklist .(' Nitrate Advisory , Septic System Advisory ` Arsenic Advisory Well Flow Advisory Other = - • (Rev.10/12112) If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: COTTONWOOD HEIGHTS S/D; BLOCK 1, LOT 14 Parcel ID: 051-431-30 A. WELL DATA *PER 1983 HAA. Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) NO Date completed *BEFORE"74" Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth *145 ft. Cased to U.K. ft. Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 11/5/2018 Static water level .��� ft. 96.6 ft. Well production g.p.m. 3.1+ g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 ml. Nitrate 8.83 mg./L. Collected by: GEG, Ltd. Arsenic: <5.0 ug./L. Date of sample: 11/2/2018 B. SEPTIC/HOLDING TANK DATA INSTALLED DOUBLE CLEANOUTS PRIOR TO NEW SEPTIC TANK. APPROVED DURING CONSTRUCTION PER PHONE CONVERSATION WITH DEB WOCKENFUSS WITH THE MOA ONSITE DEPARTMENT ON 11/27/2018 Tank Type/Material SEPTIC/STEEL Date installed 11/27/2018 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout(Y/N)`YES Depression over tank (Y/N) NO High water alarm (Y/N) NO Date of pumping NEW Pumper - C. ABSORPTION FIELD DATA BELOW EXISTING GRADE "HOUSE CURRENTLY ONLY HAS 3 BEDROOMS PER OWNER (SEE HOMEOWNER QUESTIONNAIRE) Date installed 9/2/1985 Soil rating (g.p.d./ft2or t/bdrmr 125 System type DEEP TRENCH Length 56 ft. Width 3 ft. Gravel below pipe 7 ft. Total depth *11.6+ ft. Eff. absorption area 784 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 11/5/2018 Results (Pass/Fail) PASS For **4 bedrooms Fluid depth in absorption field before test 0 in. Water added 814 gal. New depth 4 in. Elapsed Time: 195 min. Final fluid depth 0 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N &type) ***NO If yes, give date - ***SEE HOMEOWNER QUESTIONNAIRE D. LIFT STATION Date ins a -• Size in gallons Manhole/Access Y "Pump on" level at in. "Pump off' I- - . . Hi•h water alarm level at in. Da •• Cycles tested Meets alarm & circuit require - - - . E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 100'+ Absorption field on lot 1004 On adjacent lots 100'+ Public sewer main 75'+ Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank 75'+ NONE Animal containment areas 50'+ Manure/animal excrete storage areas OBSERVED SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10'+ Property line 5'± Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 1004 Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line `8' Building foundation 104 Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS *LOT LINE WAIVER GRANTED (SEE WAIVER#OSV181094) 44- isoo,sits11:1 i i•4 4. G. ENGINEER'S CERTIFICATION �4-P,.•''' C .. ♦ I certify that I have determined through field inspections and ( S ''' f/ ' % review of Municipal records that the above systems are in • • conformance with MOA COSA guidelines in effect on this i7:;1 •tE: date. ♦ f ,y A.Ga ess o 4v: • Engineer's Printed Name JEFFREY A. GARNESS ♦♦♦S�� CE-7953 ••:,S)a I V 41i7 Date 12-1 X 11_ .•<<4.:*** 4 PROFESS\Cfr 4• • LICENSE ,41111‘„`��4� #AECC884 (Rev. 10/12/12) MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT • 907-343-7904 On-Site Water and Wastewater Section Fax: 343-7997 www.muni.org/onsite Nitrate Advisory Certificate of On-Site Systems Approval # 0SC181648 Subdivision: Cottonwood Heights, Block: 1, Lot: 14 A water sample revealed a nitrate concentration of 8.83 milligrams per liter (mg/L). The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On-Site Systems Approval. Mailing Address: P.0. Box 196650 *Anchorage,Alaska 99519-6650 *www.muni.org Nitrate Fact Sheet From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids,and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. Mailing Address:P.O. Box 196650*Anchorage,Alaska 99519-6650*www.muni.org — — LAUGHLIN STREET 4. — LEGEND BASIS OF BEARINGS "S89'59'38E(M)(R) FOUND REBAR\ `1 184.94'(M) 185.00(R) j — o GARAGE ON e__ ® SEPTIC VENT LOT 13 CONCRETE FOUNDATION 19.4' ® CLEAN OUT LUMBER , WELL RETAINING WALL ;'�ti °I : 50.8' .. • GAS METER . i SEE 20'X13' `+ • NOTE 2 A ELECTRIC METER "CAR CANOPY : '\Yips/ UTILITY POST ® (SEE NOTE 3) ' '' GUY WIRE �� V STAIRS 88 DETAIL (TYP) (R) RECORD PER PLAT 71-291 j .. rn rn A t 1.• TERRACE-STYLE (M) MEASURED N N l_—' h';. .. LANDSCAPING (C) COMPUTED R8 �� j.': i LOT 14 � —oi.«,— OVERHEAD UTILITY h �� • o ib .. 9 54,874 S.F.(M) ce Q o \ `N .•k":•.Y-'1.. 1.26 AC.(R)(C) .-o ROOF OVERHANG zz , �o rn rn � GRAVEL DRIVEWAY 43., ams 0' 4.6'X7.0' ENCLOSED N N '� \�� ����� i ENTRY PORCH 3 3 WOOD DECK N o .• ..' CONCRETE PAD 1-STORY BI-LEVEL HOUSE Q Q ON CONCRETE FOUNDATION o o -M-__-- z z r ; • 8'X8' GREENHOUSE I NOT ON FOUNDATIONei 132'7 ,r PLAYGROUND ® SEE NOTE 4 LOT15 I g 010' UTILITY EASEMENT • S89'49'18"W 184.95'(C) LOT 589'59'38"E 185.00'(R) LOT 12 /' 19 �._.____�� Q /LOT o DETAIL A �---- 11 c25 0 50 NOTES SCALE: 1" = 10' enCiAG) GRAPHIC SCALE nn 1" = 50' 1. EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED PLAT, Q ARE NOT SHOWN HEREON. 2. 14.7' X 10.6' STORAGE SHED NOT ON FOUNDATION. SITS ON CONCRETE BLOCKS. 3 ?ER CLIENT, CAR CANOPY IS TO BE MOVED DURING SUMMER OF 2019. g2 'QF"A�q`ll 4. REBAR FOUND IN BAD CONDITION. HELD RECORD. DO ' \Qt.•• •••sf• it 5. DECEMBER 4, 2018 SURVEY: SURVEYED NEW SEPTIC SYSTEM TUBES. 04 e,-- r (THIS DRAWING REPRESENTS A MORTGAGE LOCATION SURVEY PREPARED IN / ACCORDANCE WITH THE ASPLS MORTGAGE LOCATION SURVEY STANDARDS. r cin '. FRANK R. BELL THIS MORTGAGE LOCATION (AS—BUILT) SURVEY IS A REPRESENTATION OF THE r 45,'',1,,:.. N0. 3252-S c1?j CONDITIONS THAT WERE FOUND AT THE TIME THE LOCATION SURVEY WAS ti F9 •, NO. 32,2-S ,•'S,k, PERFORMED AND DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THAT A SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. t,\�p9OPPSSIONAL\''a-" ' INFORMATION CONTAINED HEREON SHALL NOT BE USED TO ESTABLISH ANY FENCE, �\N`�,•' STRUCTURE, OR OTHER IMPROVEMENTS UNLESS , THE EXTENT I HEREBY CERTIFY THAT AN PREPARERRSSS SHALLEGENCE BEI LIMITEDSTOI THEVEREDAMOUNT OFLIFAEESTY COLLECT DOF FORHSERVICES ACCURATE SURVEY OF THE �N PREPARATION OF THIS PRODUCT. FOLLOWING DESCRIBED PROPERTY; COTTONWOOD HEIGHTS SUBDIVISION engineers L14 B1 COTTONWOOD HEIGHTS SUBDIVISION BLOCK 1 LOT 14 surveyors AS-BUILT SURVEY WAS MADE ON 11-06-18 & 12-04-18 AND THAT THE IMPROVEMENTS SITUATED PREPARED FOR: THEREON ARE WITHIN THE PROPERTY SHANE DENNY LINES AND DO NOT OVERLAP OR ENCROACH ON THE PROPERTY LYING DRAWN BY: WEM FLD BK: ADJACENT TO THE PREMISES IN CHECKED BY: VFS FRBA18-03 QUESTION AND THAT THERE ARE NO 801 W. FIREWEED LN. #201 JOB NO.: MOA GRID: ROADWAYS, TRANSMISSION LINES OR ANCHORAGE, AK 99503 2018-2577.01 NW 0756 OTHER VISIBLE EASEMENTS ON SAID t (907)274-5257 SCALE: `PROPERTY EXCEPT AS INDICATED HEREON. AS SHOWN DATE: 12/04/2018