COTTONWOOD HEIGHTS BLK 2 LT 3
Onsite File Gottofmlwoocl Heights t r Municipality of Anchorage " On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191448 PID Number: 05143103 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New Al Upgrade Name Watson ABSORPTION FIELD ❑Deep Trench El Wide Trench El Bed El Mound Site Address 16109 Parksville Dr ❑ Other Phone Number of Bedrooms Soil Rating depth from original grade 242-3676 4 GPD/SF JTotal Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot Cottonwood Hts 2 3 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines - Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ft2 Ft. Well 100'+ na na 25'+ TANK 0 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Greer 1250 Gal, Surface water 100'+ na na Material Number of compartments Lot Line 10'+ na na NA Plastic 2 Foundation 10'+ na na LIFT STATION Manufacturer Capacity Remarks Septic Tank Replacement- Bollards Gal. added Alarm location Electrical installed by PIPE MATERIAL House to tank Tank to D3034 drainfield Installer Dean Drainfield CO/MT D3034 Inspector BENCH MARK (Assumed elevation) 100 ft Inspection 15` 6/6/20 5/6/20 Location and description 2nd Garage Slab aro 5/18/20 ¢'h ON-SITE WATER AND WASTEWATER SECTION APPROVAL + n er' a Conditional Approval: Date * : 4 9 TM k It `�..: ........... .: ... tt± �s5s Septic System App rov�' Date 2 2 Note: this approval does not include well permit requirements. (Kev uoiuzii6) Vacant No Conflicts Q Ut 20% S < 9 d AS -BUILT MEASUREMENTS STI _A 103 B 57 ST2 107 62 dco 111 64 Ise New 1250 Gallon R Sl°pe Septic Tank w/DC❑'s Decommissioned ❑W L4 Septic Tank PER UPC 157 Slope Existing 1� Seepage Pit ° Bollards • a 15% SloPe IS% Slope Flat Slope M 4 Bdrm Undeveloped e ll �� I L3 Flat Slope I5% C SIoP L2 Flat Slop NOR THRI M "'�~�~�aM .A-:5� T Az 'k C❑TT❑NW❑❑D HEIGHTS 1p 40' ENGINEERING =��P• ' 'N## Steve Eng. com s*..: ........... . 4 BLOCK 2 LOT 3 RECORD PO Box 770724 4• • • •; s Eagle Rlver, Alaska 99577 44�+ Sh. Do •• a LAYOUT . = WASTEWATER UPGRADE 907.694.7028+� /19/L"0 REPLACE SEPTIC TANK Dot5/19/20 1`of 3 4 Ll r,.zz �o(D^ V Z VJ O Z,k r�T p o V ACU O 33 rn V coN0Z�, = V VJ J co t UT AV' Baa O 4MMpnv+oa�� z � ;;a (� :> z C-) 7;-\ M -o z o H F— M M 0 bd ry v �Q � 0 z, M d F- a d tJ H m 3 X Q F c+ hn s (D Q F -M 0�- Q C+ 0 0--1-t) LA W �+ 0 m z ro d oro L n D 7 ro D m rD < 0 -A Z ro O fU Q 7 ro -0 D Ul c+ TI T) _+ � no � a � -o �� Q Q uU) ,D Q � rD Q A rD fl I 'D 0 0 C+ - U) 1,WD rD rQ0 C+ :3_0 0o LA RD lD (11 Q (D -,D U1 n CJl ro Q 0 c ro rD rD --q ro o rn n rDQ Q rD 90 rD n S _,„,,, ,,, MUNICIPALITY OF ANCHORAGE ,,,�r�� ,e, ,_ ,of / • \ On-Site Water&Wastewater Program .N° PO Box 196650 4700 Elmore Road i6 1 r Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 t httpalwww.muni.orglonsite 1 apartment On-Site Wastewater Disposal System Permit Permit Number: OSP191448 Effective Date: 11/13/2019 Work Type: SepticTank Upgrade Expiration Date: 11/12/2020 Tax Code Number: 05143103000 Site Legal Address: COTTONWOOD HEIGHTS BLK 2 LT 3 G:0756 Site Mailing Address: 16109 PARKSVILLE DR, Chugiak Owner: WATSON PAUL MICHAEL & Lot Size in Sq Ft: 46500 Design Engineer: NORTH RIM ENGINEERING Total Bedrooms: 4 This permit is for the construction of: ❑ Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well El Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: If the septic tank is partially located in the existing parking/driving area, it shall be protected from vehicle traffic with bollards, or equal. ---z _--...sg---- Received By: Date: �D A h/ C4 111 • Issued By: [ -tet hie e / ,2� Date: .S�^ ' � � Municipality of Anchorage '-:1 ' S:1111 l•III P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Department On-Site Water and Wastewater Section x**x VARIANCE/WAIVER REVIEW **** Waiver#: OSV191085 COSA#: Permit#: OSP191448 PID#: 051-431-03 Legal Description: Cottonwood Heights Block 2 Lot 3 Engineer: North Rim Engineering Applicant: Paul Watson Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 0.0 feet. See engineer's waiver request for justifications. This waiver approval applies to the existing absorption field only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: 9 q Approved by: 6017-411 Date: // � 3 �/ pp Name of Reviewer **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE i: �0 !4� Phone: 907-343-7904 Development Services Department On-Site Water & Wastewater Section Fax: 907-343-7997 4 6 '1891 7 Nn) WI ?o ON-SITE SEPTIC/WELL PERMIT APPLICATION z OCT 0 3 2019 k Parcel I.D. 051431-03 � h� Property owner(s) Watson Paul Day phone 242-367.4! � L 9 c Mailing address 16109 Parksville Dr Site address same Legal description (Sub'd., Block & Lot) COTTONWOOD HEIGHTS BLK 2 LT 3 Legal description (Township, Range & Section) Lot Size 46,500 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: ( 1 all that apply) Initial I [II Absorption Field n I Single Family (SF)(w/wo ADU) Septic Tank ] Upgrade n Duplex (D) I Holding Tank ❑ Renewal U Multiple Dwellings Privy ❑ (SF and/or D) Private Well n Water Storage Ix I THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Existing Seepage Pit To Lot Line-Assumed Distance: 0Y I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (e-------re of property owner or authorized agent) Permit/Rush Fees: 3'35 Waiver Fees: 4A)►5 Date of Payment: IO 131Iq Date of Payment: 16op9 Receipt Number: U(aaWb Receipt Number: OCp?lb Permit No. 65 P!ait-148 Waiver No. �v I_f I b5 G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc NbTFIM ENGINEERING SteveEng.com Steve Eng, PE, PH 907-694-7028 SteveEngPE@gmail.com Date: 10/3/19 Number of Pages: To: MOA On-Site Services Subject: Cottonwood Hts Block 2 Lot 3 Septic Tank Failure The subject septic tank has failed- a new tank will replace the old one. The existing seepage pit appears to be working OK- it has been functioning for many years. The seepage pit appears to be directly on the property boundary- we are requesting a lot line waiver to 0-feet. Please issue a permit so the tank can be replaced. The existing seepage pit will remain. Please review as soon as possible. If there is need for additional information or clarification please give me a call. Thanks-Steve \ RTI--ZIIV ENGINEERING Cottonwood Hts Block 2 Lot 3 SPECIFICATIONS & DESIGN GUIDELINES Water System Sizing: This is an existing 4-bedroom home. Most of the neighboring lots are undeveloped. A surface water collection system currently provides water for the residence. The surface water system functions& would likely be approved in many areas of the State. A surface water stream is impounded on lot 2. The impoundment contains a clear well with pump that transfers the water to a water treatment room off the garage.The water is filtered through two cartridge filters, followed by UV disinfection. Two Well-X-Trol pressure tanks @ 30 gallons each provide additional storage. This water system has provided year-round service for the residence. There is also a water well that was drilled in 1977,well log in MOA file. The well is very deep at 635',drilled into bedrock. M-W Drilling reported the well flow @ 20 gph in 1977. A well flow test was recently conducted. A 4-hour flow test was recently conducted on the well,with monitoring for 24-hours. The static water level was found to be 42.8'. This amounts to a water well with a 592'water column. This amounts to about 870 gallons of water storage in the well. During the well flow test,the water level was drawn down below 600'. Recovery measurements were made to determine well flow. The well flow was near 2 gpm recovery below the 600' level. The recovery rate diminished as the water rose in the well,to 0.75 gpm. It appears that with the large storage of the well,coupled with adequate flow below 600',the well could provide a groundwater source for the residence. A water line would require construction to the house,meeting MOA requirements. It appears that the existing pressure tanks could function, coupled with the large storage in the well. The well casing extends above ground level,however a pit surrounds the casing which should be filled in. The casing should be grouted with bentonite when this void is filled. If this bedrock well flow were to diminish in the future,the well casing could be filled by a water tank delivery. The existing surface water system could serve as irrigation. OF •Acs+1 per •.' � !$ Steven A'. Frig . ,i*tof X6 8%R OFESSkv �CRTHI M ENGINEERING Cottonwood Hts Block 2 Lot 3 Wastewater System Sizing: The current septic tank has failed-the seepage pit still functions.This lot is over an acre.No adverse impacts are expected from tank replacement. The easements are depicted on the lot. The slope is indicated in the area of the septic system.No conflicts to neighbor properties. Protective bollard could be placed around the tank at the edge of the driveway.The seepage pit is located at the property line.During tank construction a steel probe could be used to determine the extent of the seepage pit in relation to the property boundary. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications(AMC)& State of Alaska Drinking Water Regulations and Wastewater Regulations. • New 2- compartment, 1250 gallon septic tank. Watertight couplings on inlet&outlet. • 5' minimum between the tank and trench. 5' to property lines& 10' to house. • 4' of cover or insulation is required for tank; an equivalent of 1" insulation for 1' foot soil cover. Tank&solid pipe must be set on well compacted, stable soil. • No large rocks for tank bedding. Plastic/fiberglass tanks require special bedding per MOA- sand or pea gravel. • 4" diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment,and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. • All cleanouts must extend to at least ground level. • In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. • Insulation must be placed over any pipe installed under driveways or parking areas. • Approved pipe materials include cast iron,PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, • Sewer Service Line is minimum 2%slope. • Septic Tank to be pumped every two years or when required. • Insulation board to be extruded direct burial polystyrene(Dow Styrofoam HI/equal) • , 4, . *e• iv e .‘ *4..• 4: : ;y, Steven W. cng • �<v® /� • 56s• 144 '/ ��� @R �l SS`O" 42, DESIGN NOTES: 1 . Existing Seepage Pit Remains In Place. Seepage Pit Assumed To Be Totally On Lot 3. 2. Sewer Service Line minimum 2% slope. 3. Replace Septic Tank/Decommission Old Tank Per UPC. 4. Lots Served by Private Water Wells. 5. No Conflicts Within 200'. 6. Check Condition Of Sewer Service Line— Replace If Necessary. 7. Measure Separation Prior To Construction. 8. Add FCO or DCO Prior To Tank If FCO Absent. 9. MOA Spec For Tank Bedding. cb Sand Or Pea Gravel For Plastic/Fiberglass. 10. Install 6"x6" Protective Bollards Around Tank In Driveway. I _ I I 15x Pe New 1250 Gallon Sl° Septic Tank w/DC❑'s Decommission Old L4 Septic Tank PER UPC 1S% Slope Vacant 14 1 Existing c---7 Flat Slope 1 No Seepage Pit 1 / Conflicts . Existing ank 15Z Slope 4 Bdrrn 2 ,,,, tfl N 20Z Slop- - -- 15Z Slope ro ,.L fco Undeveloped -5 100 ell L3 Flat Slope 15x Slope R 00 _I L2 Flat Slop: NOR THRIM •-�1.1,..„v,`tIn = 40' ;•P��.°F......... CDTT❑NW❑❑D HEIGHTS ENGINEERING �'�.. ' steveEng.com * :4sm * BLOCK 2 LOT 3 DESIGN PO Box 770724 LAYOUT Eagle River, Alaska 99577 9 1, WASTEWATER UPGRADE 907. 694. 7028 N <<I" ( Dote r2iEET ,' REPLACE SEPTIC TANK 11/2/19 3 Foundation Cleanout Tank Cleanouts Fin amide Opposing Cleanouts Between Septic Tank & Trench Riser 4 Foot Cover Per or Equal MOA d` S vi / 1250 Gallon To Seepage Pit MOA-Approved Septic Tank lid Pipe Match Elevations To DESIGN NOTES Existing FCO & Line 1. Use Existing Seepage Pit. 2. Septic Tank & Solid Pipe to be Placed on Compacted, Stable Soil, Free from Boulders. 3. Sewer Service Line is Minimum 2% Slope & 3' Cover. 4. Water-Tight Couplings. 5. See Specification Sheet. 6. All Work To Conform to Municipality of Anchorage (AMC) Requirements & Specifications. 7. Decommission Old Septic Tank Per UPC. 8. Check Condition Of Sewer Service Line. Replace And/Or Insulate If Necessary. 9. Use MOA Spec For Bedding Depending On Tank Type. 10. Riser Per MOA Specification. NOR THRIM °F ENGINEERING ".. ' SEPTIC TANK PR❑FILE COTTONWOOD HEIGHTS SteveEng.com •49mi. � '• PO Box 770724 t; BLOCK LOT 3 Eaglet River, Alaska 99577 44,�'•7 , � 907. 694. 7028 I/ TANK REPLACEMENT Doty.10/2/19 rum By SE IScok: i• = 5 , SHEET•3 of 3 SE HOUSE DETAIL Scale: 1" = 30' COVERED CONCRETE ENTRY–\ -- --> 88.2' 16.5' 16.0' • N R a O o c w' 2 STORY RESIDENCE ce 0 n „. "r • iv 0 o Q a F NI a Q v va - 0Z°- ^ 56.0' o 0' to 15.8' U 4 p eo8.0O --1 c,:12.4 Lot 4 30.0' I ~� 7.9'x8.2' SHED ENCROACHES 6.2' S 89'56'13"E 310.00' • -13 I SEPTIC PIPES _ > Lot 3 — -�... xi Z 1.07 Acres X o 38.1' 0o c q / m C0. • o , •a m cm .. / AR 4v o o a.m a 0 R4440 Cri�F `c-64- 9 0 a it7 Ci4, rl I • WELL ', I N 89'56'13"W 310.00' fi Lot 2 / 10' UTILITY / EASEMENT PLOT PLAN AS BUILT X SCALE 1" = 60' GRID – NW 0756__ Project No. 19-566/A1 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates , inc . (907) 522-6476 Phone QogpppO (907)ke522-4625 2 –462 comax oQ O F A L 444 Professional Land Surveyors jonatha Olangsurvey.com �, ........-95440 oma,? ,i- 0 I hereby certify that I have surveyed the following described property: 0( 49Th /\ .':7 V4 LOT 3, BLOCK 2, COTTOWOOD HEIGHTS (PLAT No. 71-291) Q Anchorage Recording District, Alaska, and that the improvements situated thereon that ^� VA re VA within the property lines and do not encroach onto the property adjacent thereto, Q no improvements on the property lying adjacent thereto encroach on the surveyed COn7� KENNETH G. LAPt premises and that there are no roadways, transmission lines or other visible V easements on said property except as indicated hereon. q O 00�3��F, 1.35102. • SJp� Dated this the 'ori!, Day of _?WVrtAk:o..--t- _, —__ , at Anchorage, Alaska Q1,°,o,Qo •''••'''' �r1� O P QO tSS10NA1- o. It is the responsibility of the owner to determine the existence of any easements, \Opppo�a covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963 ~UNICIPALITY OF ANCHORAGE He~ ~ and Environmental Prote 3n Fourth Floor West 825 L Street Anchorage, Alaska 99501 264-4720 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME __aA~-~,,, ~ ~,~c ~ LOCATION ~--~ d,'.%~'.,,,~ '~"{-, __ MAlt_lNG ADDRESS ?.(.% %~r~ ~ |~ LEGAL OESCR,PT,oN__L ::::) ¥ $ %~ SEPTIC TANK: [~OM W~LL INSIDE LENGTH. MANUFACTURER (-¢~(~ MATERIAL _ INSIDE WIDTH LIQUID DEPTH NUMBER OF I COMPARTMENTS LIQUID CAPACITY ! ~$~,~ALLONS. TILE DRAIN FIELD: DISTANCE FROM WELL FOUNDATION_ NEAREST LOT LINE TOTAL LENGTH OF LINE '# of Lines DISTANCE BETWEEN LINES __TRENCH WIDTH . ,. IN. TOTAL EFFECTIVE ABSORPTION AREA__~ SQ. FT. LENGTH OF EACH LINE DEPTH OF FILTER DEPTlt: TOP OF TILE TO FINISH GRADE MATERIAL BENEATH TILE __IN. ABOVE TILE ,IN, SEEPAGE PIT: DIAMETER __ Log Crib Rings ~ Crib - I BUILDING FOUNBAI'ION_~__O,~- NEAREST LOT LINE TOTAL EFFECTIVE ~ ABSORPTION AREA (WALL AREA) SQ. Size: DIAMETER-~--~--DEPTH-I<~ DISTANCE FROM: WELL FT, Well Well Distance Bldg: Sewer Pipe Materials: ~ of Bedrooms: Installer: ~ Remarks: ~o,F Depth: ~qO · o: Lot Line Line: DATE LO["")/"'II APPROVED ; 'l C�5 j6 62,v\. - Qp C— Well Owner Location DRILLING, INC. MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION Allen Plancich DRILLING LOG MAR 2 4 1981 RECEIVED Use of Well (address of: Township, R~a~u~e, Section, if known; or distance main road Size of casing Depth of Hole Static water level 156 ft. ~e) Screen ( ); Perforated ( Describe screen or perforation Well pumping test at 20 gallons per (hour) of drawdown from static level. 7/18/77 Date of completion 635 feet Cased to 36 .feet (below) land surface. Finish of well (check one) ). open end ( xx ); for I hours with 100% WELL LOG Depth in feet from ground surface Give details of formations penetrated, size of material, color and hardness 0 TO. 2 Casing stickup 2 TO. 3 Gravel Fill 3, TO 4 4 20 TO. 20 TO 32 32 TO. 635 ...TO TO. TO. TO. TO. TO. ~O. TO. TO. Organics Silty gravel, cobbly Silty ~ravet Bedrock: green stone; water se~p~ in fractures throughout spnrad4c - ~-~mlt:u c, onu'aetor Certi£ieate No's. 814 & fi/3 1 -- CUSTOMER III I-L J...HNI L..L.IL.:H I I. L N I'qJ. it'4.kl"lLIl"'l I..:~.1.:=,1 Hr'4L;b. f31:_' IHb. E:.N H P~:.L.L. HNL) HN"r' I..IN-~,t IF: :::,b. 14Hl.jl:: L)I'::,F'I...I:::,HL '.:::,¥I:,tb. 1"1 .'.Lk.l~.:.~ P.t=.I'::.I I-Uh:'. H I'-'I-.'..L',,,'HII= N~::.L.L.. L.II.,:'. ;~:1~...t FE:.~=.t F'LIt~.'. H I-'I..IE:IL..LL: H~::.I...L.. L.L.IL~'.':., Hh.'.'L". P.'.I=L:.!U ~ N'.~:L.) HNL) HLr.:, I liE: h::L-., t L.I~,.'.'r.4L:L:~ i U I lq'l= L.:q:=I-'HI-.'. J r'll=N t ~,4 .t. 1 H J. N .~:~.:.1 l..)H"r't::, LJI'" IHI::. PJ~:I_L. I_:L.II"I~-'L..E: I .L L.IN. U I H~::.I~.'. ~,..'I=.I.:.!L..I J. N~:.M~.:'.r'4 I :=, r'lH'.r' HP.'~;'L.'Y. '..:..,p.'~=l_: .L t- J. L:H i 1 LIN:=, HNL) I..:LIN::, I N'.L.IL: I L LIN L) t HI=iI.-.'.HH?., HN'.I= tq'VH J. LHE:;Lk:- I U J. N::,L.II.,:'.-L t'-"~'.'.LII-'E:.I":.' .I. r'4::::, I HL.L..H I 1 UN. 0 & E GEO _CHNI CAL & ®EVEL - .1MENT CO. Box 90, Davis St., Eagle River, Alaska 99577 694-2774 or 688-2280 Russell Oyster Earl Ellis 694-2774 SOIL LOG 688-2280 Soils Er Foundations Land Development Performed for: Name: Tel. No. Mailing Address: Legal Description: Depth (feet) Soil Characteristics 0 1 z 3 4 5 6 7- 8- 9 . 89. 10 11 12 13 14 15 16 Ground Water Encountered: Yes- No-- If yes, what depth Proposed Installation: Seepage Pit Drain Field Comments: Performed by: Date: -~ ~-:~- I NSPECTIONAPPOINTMENTS _ ~ ~ --r ~ TIME · . ,;_ !, ' ~-~ DEPARTMENT O1= HEALTH.&ENVIRONMENTAL pROTECTIONOEPT. OF HEALTH & .- ~~% " 825 [ are.; Anchorage; AI.k, 895m . _~ImNMENTAL PROTECTION _ ~ : Telephone 2644720 . DIRECTIONS: Complete all parts on page 1. In=omplete rsqu.~ will not be pr~d. Ple~ allow ten (10}days for~processing. , ~. ~n0.;RTVOW~;n .... PHONE ' MAILING A~E~ / ......... ~' ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ r P H N[ P~OPEHTY ~ESIOENT (If dif~rent from above} __ ~ ~ ~ O E 2. BUYER " ' MAILING ADD~ESS ...... 3~ ~'LENDING INSTITUTION .... / 'MA'I LING ADDRESS ' 4. REALTOR/AGENT ' ' ' ' ' ' ' ~ PHONE I UA~UNa ADOnESS :)CATION [] SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY [] 'Three' [] SiX* 7. WATERS~LY · . - - []~ INDIVIDUAL* *ATTACH WELL LOG. AWelt log is required for all wells drilled [] COMMUNITY . s nce June 1975. For we Is dri ledprior to that date, g ve we ~' _.'-" [] PUBLIC UTI LITY depth (attach Iogif available.) - liar/ INDIVIDUAL/ON-SITE** YEAR ON-SITE SYSTEM WAS INSTALLED, THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OI~"RESlDENCE [] SINGLE FAMILY [] ONE [] MULTIPLE FAMILY [] TWO [] FOUR 2. WATER SUPPLY [] INDIVIDUAL [] COMMUNITY [] PUBLIC UTI LITY Connection Verified 3. SEWAGE,~DISPOSAL SYSTEM [] INDIVI DUAL/ON -SITE I--I PUBLIC UTILITY Connection Verified []Septic Tank or' [] Holding Tank Size: I D..~C~ If Tank is homemade give dimensions: TYPE OF TANK TOTAL ABSORPTION AREA 4. DISTANCES WELL TO: NUMBER OF BEDROOMS [] THREE [] FIVE [] OTHER [] SlX Absorption Area to nearest Lot Line PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED PERMIT NUMBER DATE INSTALLED INSTALLER SOILS RATING MANUFACTURER ~ MATERIAL Septic/Holding Tank ~Absorption Area Sewer Line i Nearest Lot Line 5. COMMENTS DATE [] APPROVED FOR BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [~ DISAPPROVED 72-010 (REV. 6/79) 825 "L." STREET ANCHORAGE, ALASKA 99501 (907) 264-4111 G[~ORGE M. SULLIVAN, MAYOR ()EP/z',H'fCdF N'F OF ~!EAI..TH AND ENVIRONMENTAL PROTECTION March 27, 1981 Freda A. Pl. ancich Post Office Box 8-9134 Anchorage, Alaska 99507 Subject: Lot 2 and 3 Block 2 Cottonwood }{eights Subdivision Approval for your individual sewer and water facilities cannot be granted until the following items have been completed: (i) The water anlaysis report needs to be delivered to this office from the Chem Lab, 5633 B Street, for our review. (2) The well is in a pit. The sides will need to be repaired and the bottom poured with four(4) inch concrete slab in order to prevent surface water instrusion. (3) The to'r) of the well casing sealed with a sanitary seal so that it water 'tight. Please notify this department for a reinspection when the noted descrepancies have been completed. If there are any further questions, please call this office at 264=4720. Sincerely, Robert. C. Pratt, R.S. Associate Specialist RCP/ljw MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 051-431-03 1. GENERAL INFORMATION Expiration Date: Complete legal description COTTONWOOD HEIGHTS BLK 2 LT 2&3 Location (site address) Current property owner(s) Mailing address Real estate agent 16109 Parksville Dr WATSON PAUL 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Day phone 242-3676 Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well El Private Septic' 0 Water Storage ElHolding Tank 1Ii ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer', ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ SGJ� Li a .S� Waiver Fee $ Date of Payment Jc /z/ / ZWzb Date of Payment Receipt Number cc Receipt Number COSA # 99 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of ' bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm NorthRim Eng. Phone 694-7028 Address PO Box 770724, Eagle River Engineer's Printed Name Steve Eng Date OF �,�1��� *% 1 s * :49I1i , 6. DSD SIGNATURESteve En ; System #1 Approved for bedrooms #,� = 9dIF. ' %+ System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, with the following stipulations: OF E W � N Original Certificate Date: N The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA Checklist blue sheet Nitrate Advisory Arsenic Advisory Other Legal Description: COTTONWOOD HEIGHTS BLK 2 LT 2&3 If more than 1 septic system on lot: COSA Checklist # of Parcel ID: 051-431-03 Structure served by this system A. WELL DATA ❑ Well log is filed with Onsite (or attached) Well production at time of test 0.75 gpm Date drilled 7/18/77 Water storage tank volume 0 gallons Total depth 635 ft Well disinfected for coliform test? ❑ Yes ❑ N Cased to 36 ft ❑ Coliform bacteria is Negative ❑ Sanitary seal is functioning correctly Nitrate 0.8 mg/L ❑ Nitrate less than MRL (ND) ❑ Wires are properly protected Arsenic ug/L ❑ Arsenic less than MRL (ND) Casing height (above ground) 18+ in. Collected by NRimEng Date of flow test for COSA 9/30/19 Date of Sample 5/19/20 Static water level at beginning of test 42.8 ft. Comments 0.75 gpm In 4 -Hr Flow Test- Seasonal Flow Variation In Well Is Possible B. TANK DATA Age of tank(s) new years Tank type/material Plastic Measured operating fluid level in septic tank new ❑ Standpipes/foundation cleanout per record drawing Date of pumping new - D. ABSORPTION FIELD DATA 10/7/77 Which system tested (date installed) same ❑ ALL standpipes present per record drawing Total measured depth from grade 25 ft (max) Measured depth to pipe invert from grade 15 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date 9/30/19 Results ❑✓ Pass For 4 bedrooms Fluid depth prior to test 0 in Water added 600 gal New depth 15 in Elapsed time 60 min Final fluid depth 8 in Absorption rate 600 gpd Any rejuvenation treatment (past 12 months) If yes, enter date no E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' 0 Yes Community Severer Manhole/Cleanout > 100' Yes if No ft 0✓ Yes if No ft Neighboring Tank > 100' Q Yes if No ft Private Sever/Septic Line > 25'✓Q Yes if No ft Absorption Field on Lot > 100' r7l Yes if No ft Holding Tank > 100' ❑f Yes if No ft Neighboring Absorption Fields > 100' Fv� Yes if No ft Water Main > 10' Animal Containment > 50' Q Yes if No ft M✓ Yes if No ft Q Yes if No ft Water Service Line > 10' M✓ Yes if No Manure/Animal Excreta Storage > 100' If septic tank is under driveway Community Sewer Main > 75' ✓M Yes if No ft Fv Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water > 100' Yes if No ft Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots: M Absorption Field > 5' M✓ Yes if No ft Private Wells > 100' Fv� Yes if No ft Water Main > 10' F71 Yes if No ft Community Wells > 200' Q Yes if No ft Water Service Line > 10' M✓ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' [Z] Yes if No ft If absorption field is under driveway comment below Property Line > 10' M✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' M Yes if No ft Private Wells > 100' Yes if No ft Water Service Line > 10' ✓M Yes if No ft Community Wells > 200' Yes if No ft Surface Water > 100' F,71 Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION I certify that t have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet OF � 4 `�...... Stepro ir `� CE -6256' "N s Municipality of Anchorage 8. Development Services Department a:. Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www. ci. anchorage. ak. us (907) 343-7904 Water Well Advisory Certificate of On -Site Systems Approval (COSA) # OSC201199 During a recent COSA on-site inspection and test of the potable water supply well on Block 2, Lot 3 of Cottonwood Heights subdivision, the well's productivity was determined to be .75 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 4 -bedroom residence is .41 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. HOUSE DETAIL Scale: 1" = 30' W -C U~ Zn COVERED CONCRETE ENTRY 0-1 2 STORY RESIDENCE 56.0' Lot 4 16.5" 16.0 E— tY t— O EL O o W a- Co U Q U 7.9'x8.2' SHED ENCROACHES 6.2' S 89'56'13"E 310.00' SEPTIC PIPES_ Lot 3 1.07 Acres `-WELL a N 89'56'13'W 310.00' Lot 2 I 0 10' UTILTYJ EASEMENT PLOT PLAN ___ AS BUILT _X_ SCALE 1= = 6�=_ GRID _ NW 0756M Project No. 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates, inc. (907) 522-6476 Phone 4©QQD�DO (907) 522-4625 Fax �Q 4 Professional Land Surveyors ken0langsurvey.com OF 4 �4 0 ]onathan®longsurvey.com ©P gs4�o 1 hereby certify that I have surveyed the following described property: ��K ' LOT 3, BLOCK 2, COTTOWOOD HEIGHTS (PLAT No. 71-291) p * . 49TH Anchorage Recording District, Alaska, and that the improvements situated thereon are"""" " within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed d•�' KENNETH G. LANG premises and that there are no roadways, transmission lines or other visible Q r� o G easements on said property except as indicated hereon. '•.LS -5202.•' Dated this the zo}Day ofF���` ,�? at Anchorage, Alaska 404 0 SSiONIt Oo It Is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963