HomeMy WebLinkAboutCREEKSIDE PARK #3 LT 25N
L
' APPLIC aT FILLS OUT UPPER HAL ~)NLY
Propert~ Owner~,. ~.~ /~-? ~'~,X~,~..)~ Phone
Mai?ng Address 7~..~ ~/ ~/,// /~f~;~.~ ~'2U ('~ Zip Code
Buyer
Address Zip Code
Lending Institution W6 ~ Phone
Address J~/(7~-~x/) ~ / ~./~'?_/ ~""~cj j,//_.) Zip Code
Realty Co. & Agent Phone
Address Zip Code
Legal Description ~.~'J~.~ ~11~' .~,t~.~l~ / ,~.~'
Type of Residence
~ Single Family
I--I Multiple Family No. of Bedrooms
~] Other
Water Supply [~ ,~'~
~TTACH WE[[ LO~. A w~l log is required for all wells dril~l since dune 107~.
~--Communit~/ ~ For wells drilled prior to that dat~, g~¥e well depth {attach log if a~allablel.
'~ [] Public Utility .
[] Individual ~ Year Indi¥idual Inatalled:
[] Public Utility When Connected to Public Utility:
[] Holding Tank
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
Time Time Time Time
Date Date Date Date
Inspector Inspector Inspector Inspec~.~r
Field Notes:
MUNICIPALITY OF ANCHORAGE
DEPT. OF H~ALTH
~ ~'"~'~,~ ENVIRONMSNTAL PROTECTION
~' DEC
= RECEIVED
( ) DISAP~OVED ~~ ~,~~
~, ) CONDITIONAL APPROVAL*
DATE I -~ ~--g ~
BY: C~ L~'~~
Soils Rating Date ~wer Installed Well To ~sorption Area Well Log Received
~ Well to Tank Septic T~k Size
72-023 (3182)
December 14, 1983
Jack M. Alexander
7301 Old Harbor
Anchorage, AK 99504
Subject: Lot 25, Creekside Park Subdivision 1
Approval for the individual sewer and water facilities cannot
be granted until the following items have been completed:
The septic tank pumped with a receipt submitted to this
department. The total number of gallons pumped needs to be
on the receipt and verified by a registered engineer as to
the actual number of gallons pumped. This is to verify the
size of the septic tank.
An adequacy test needs to be i~rformed on the existinG
leaching area. This test will determine if the system is
adequate according to National Standards. A listing of
private firms performing the test is enclosed. This report
needs to be submitted to this office for our review.
four (4) inch cleanout needs to be installed to the
<~ leachin~ area.
Please notify this Department for a reinspection when the
noted discrepancies have been corrected. If there are any
further questions, please call this office at 264-4720.
Sincerely,
Jim Roberts
Associate Environmental Specialist
JRll/ej~E1
Enclosure
cc: National Bank of Alaska
Northern Lights Boulevard
Anchorage, AK 995
ENGINEERING INNOVATION tN TH~'~E FAR NORTH
ARCTIC ENGINEERS, INC.
ENGINEERING STUDIES ', DESIGN o CONSTRUCTION MANAGEMENT * SURVEYING
January 20, 1984
AEI# 84-003-01
Jack Alexander
7301 Old Harbor Ave.
Anchorage, Alaska
SEPTIC SYSTEM ADEQUACY TEST
LEGAL:
OWNER:
HOUSE TYPE:
WATER:
SEPTIC SYSTEM:
TEST DATE:
PROCEDURE:
Lot 25, Creekside Park Subdivision, Addition
#3
Jack Alexander
3 Bedroom, 2 Story, Single Family
Municipal
Tank: ~¢'.., ~:
Absorption System: Unknown
Absorption Area: Unknown
January 19, 1984
The adequacy test was started at 2:15 p.m.
There were no stand~_t~e~u, t4~ le~#$m9 area, so water was
added to the system through the septic tank. ~ow rate
steadx at 7.5 gwm. MoJ~it~ri~af w~er level in the tank was
performed coa[inuously throughout the test using a float.
~QQ. gallons (2 times the daily design flow) was added to the
system with no ~igltif~(cmmt rise in li~i'~ level.
~:,~ J .... [_.::] .... ~r ~-:~eted, the tank was pumped, yielding a
6aPaE-{'ty O~ 1060 gallons.
RESULTS:
The absorption system accepted 2 times the daily design flow
of 150 gallons per day, per bedroom. The tank capacity was
determined to be 1000 gallons. The septic system is adequate
by Municipality of Anchorage Standards.
ARCTIC ENGINEERS, ..,,~m"'"'. w. 99 o . 907/277.8593
3901 PATRtCIA LANE ,, ANCHORAGE, ALASKA 99504 · 907/333-9428 (AccOUNTiNG)
--ISAACS PUMPING SERVICE
(Norm Tibbetts, Owner)
6218 Quinhagak Street
ANCHORAGE, ALASKA 99507
Phone 563-3300
All claims and returned goods MUST be
accompanied by this bill,
1361
ENGINEERING INNOVATION IN TI-{~AR NORTH
ARCTIC ENGINEERS, INC.
ENGINEERING STUDIES. DESIGN ,, CONSTRUCTION MANAGEMENT · SURVEYING
May 30, 1984
AEI# 84-003-01 HAA
National Bank of Alaska
Mortgage Loan Department
Attn: Maryann Fisk
Re: Septic System on Lot 25, Creekside Park ~3 for Jack
Alexander
Dear Ms. Fisk:
This letter is sent as a follow up of our letter dated 1-19-84.
The above referenced system was re-inspected 5-30-84 and now has
an absorption field sump in place and is in compliance with
MOA-DHEP requirements.
If you have any questions pertaining to this matter, please do
not hesitate to call.
Sincerely,
ARCTIC ENGINEERS, INC.
David Yanoshek, P.E.
DY/tel