HomeMy WebLinkAboutCOLLIER Lots 1-4 Plat# 84-055 S-7126  MUNICIPALITY OF ANCHORAGE , DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION Environmental Health Division CASE REVIEW WORKSHEET CASE NUMBER: DATE RECEIVED: COMMENTS DUE BY: S-7126 June 2, 1983 June 17, 1983 SUBDIVISION OR PROJECT TITLE: Lots 1 - 4 Collier Subdivision (1'~PUBLIC WATER AVAILABLE (tt ) PUBLIC SEWER AVAILABLE ( COMMUNITY WATER AVAILABLE COMMENTS: 71-014 (Rev. 5/83) NHAWTHO RNE-ENGINEERIN.G 23 May 1983 Ms. Judy Collier Star Route A Box 403 Anchorage, Alaska 99507 ,.:- .... , i HOr<,4,- - ENGINEERING ~:~'~.:, Old Ss'.'.'ard F: _:;,'.'.':v. c-,ncr,., AK ,°,0t502 34.4 - 471 ! Re- Soils Investigation Subdivision of E½,NE¼,NE¼,SE¼,S26,T12N,R3W,SM Dear Ms. Collier; In response to your request we have performed a ~rel~minary soils investigation of the above named property. The purpose of this investigation was solely to provide subsurface data for use by the Municipality o~ Anchorage Dept. of Health and Enviromental Protection (DHEP) in determining the suitability for on-site waste water disposal. On May 19, 1983 we drilled 3 test borings to 20 feet with adjacent shallow borings for percolation testing. Each set of holes was on a different proposed lot as shown on a preliminary subdivision drawing by Hewitt V. Loundsbury & Associates. The borings were drilled with a Bombardier mounted drill rig using 6" solid auger owned and operated by Oosik Drilling, Inc. The 20 foot holes were'logged and samples were kept for later laboratory analysis should that be required by DHEP. The soils were classified visually in the field according to the Unified Soi-ls Classification System and were not verified with laboratory analyses. A one inch perforated pipe was installed in each test hole for later .obsefivation of any water table. After drilling each deep test hole a second boring was made to the most likely strata for percolation testing. The perc holes were placed about 5 feet from each deep test hole. A 4 inch perforated pipe was. installed in the perc hole and gravel placed around &nd inside the pipe. 12 to 18 inches of water was poured into each perc hole and the holes were left to soak overnight. On May 20 I drove to the site and measured the percolation rates according to DHEP standards. Soils information and percolation rates are shown on the enclosed attachments'.' One of the test and percolation hole pairs (Lot 3) showed a high ground water level and extremely slow percolation rate. There S 71 2 ¢., .2... 01983 is a failed septic system approximately lOOft from the holes which could be causing the problem with water running immediately below the surface. Mr Robert Robinson of the DHEP told me that they will probably approve the subdivision for on-site waste water disposal if two thirds of the subdivision perc holes are satisfactory and there is no reason to' assu~e a suitable location c2n not be found for the remaining lot. It must be understood, however, that another percolation test will be required and it must pass before construction on Lot 3. All separation distances required by DHEP will apply. Thank you for this opportunity to be of service.' If you Fequire more testing please let me know. Si-ncerel~{~ Neil Hawthorne Attachments ~i~ SOl LS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST PERCOLATION TEST PERFORMED FOR: LEGAL 3 9- 10- 11- 12 13 14 17 T~ .... · Lo D E S C R I PT I O N ()~ ~c,,'r"~' ~ 3 SLOPE ~OU~WATER ,0 : :..,.r.l/,.u s was E,COUNTERED? L IF YES, ATW,r .Se,-.,,,/ P^y DEPTH? SITE PLAN I i l' Reading ~1~,,,,.. Gross ~Net Depth toI Net Time j Time Water Drop PERCOLATION RATE (minutes/inch) TEST RUIN' BETWEEN ~' FT AND ~ '~/-~- F-T MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SOl L$ LOG y PERCOLATION TEST SLOPE 2 3 4 10 11 12 13 14 15 16 17 18 19 WAS GROUND WATEI: ENCOUNTERED? I I IF YES, DEPTH? SITE PLAN Gross Net Depth to Nel Reading DaTe Time Time Water Drop PERCOLATION R4,TE~?~ '~--.~O -- -~rTmf~b-,a/i~-c-h) .... C OL':t4 E NTS MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION ~25 L, Street, Anchoraoe, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SO1LS LOG PERCOLATION TEST PERFORMED FOR: .5'~.,V-,).' 4 5 S,._~, ~)~ 6 7 8 9 10 11 12 13 14 15 16 17 18 19 SLOPE IF YES, AT WHAT DEPTH? DATE PERFORMED: //~-,'~, W' /..~ /.~, / SITE PLAN , I I I I I I III I I I I I I Gross Net Depth lo I Net Reading Daze Time Time Water Drop 4 ~ I~,'~ ~ ~ .,~ ,.,-- ¢~L :;...zI . _.._~.,~,~ ~- i 9+ I PERCOLATION' RA~E ~~ I ~ (,minu,e~/inch) TEST RUN BE~,'.'EEN '~ ~T AN'D .~ O- ET CON',I/, E NTS /t/ tt v'¢ ,,, t -2 · \ NHAI¥THO RNE-ENGINEERING 23 May 1983 Ms. Judy Collier Star Route A Box 403 Anchorage, Alaska 99507 ,~-,..~.,~ ;HOr, N~_ - ENGINEERING ....,:~,, O15 Se'.'.'erS Fi Z~'-.v.'--';' hr, cF.., AK 99502 344-4711 4 1 0 1 /~R~¢TIC ~OULEVArD ANCHO,,~,Z,~-.F_, A_ASK.A 99503 Re' Soils Investigation Subdivision of E½,NE¼,NE¼,SE¼,S26,T12N,R3W,SM Dear Ms. Collier; In response to your request we have performed a prelSminary soils investigation of the above named property. The purpose of this investigation was solely to provide subsurface data for use by the Municipality of Anchorage Dept. of Health and Enviromental Protection (DHEP) in determining the suitability for on-site waste water disposal. on May 19, 1983 we drilled 3 test borings to 20 feet with adjacent shallow borings for percolation testing. Each set of holes was on a different proposed lot as shown on a preliminary subdivision drawing by Hewitt V. Loundsbury & Associates. The borings were drilled with a Bombardier mounted drill rig using 6" solid auger owned and operated by Oosik Drilling, Inc. The 20 foot holes were'logged and samples were kept for later laboratory analysis should that be required by DHEP. The soils were classified visually in the field according to the Unified Soils Classification System and were not verified with laboratory analyses. A one inch perforated pipe was installed in each test hole for later observation of any water table. After drilling each deep test hole a second boring was made to the most likely strata for percolation testing. The perc holes were placed about 5 feet from each deep test hole. A 4 inch perforated pipe was. installed in the perc hole and gravel placed around And inside the pipe. 12 to 18 inches of water was poured into each perc hole and the holes were left to soak overnight. On May 20 I drove to the site and measured the percolation rates according to DHEP standards. Soils information and percolation rates are shown on the enclosed attachments'.' One of the .test and percolation hole pairs (Lot 3) showed a high ground water level and extremely slow percolation rate. There S71 2 6 JIlL 2 01983 is a failed septic system approximately lOOft from the holes which could be causing the problem with water running immediately below the surface. Mr Robert Robinson of the DHEP told me that they will probably approve the subdivision for on-site waste water disposal if two thirds of the subdivision perc holes are satisfactory and there is no reason to' assu~e a suitable location can not be found for the remaining lot. It must be understood, however, that another percolation test will be required and it must pass before construction on Lot 3. All separation distances required by DHEP will apply. Thank you for this opportunity to be of service.' If you ~equire more testing please let me know. Si'ncerely~ / ~ / . //'7 Neil Hawthorne Attachments SOl LS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PRQTECTION 825 L Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATIQN TEST PERCOLATION TEST 6 7 9 10 11 12 13 14 15 16 17 18 19 T, ~.___ 20 ;d ~c~7 ~ r ~r DATE PERFORMED: ~//~ --~ SITE PLAN WAS GROUND WATER (~'~r;)]'~[ S ENCOUNTERED? ~'/ L 0 IF YES, AT WHAT Gross Net Depth to Net Reading Date Time Time Water Drop ~'/~o t; aS' :~-/¢ ' I I ' PERCOLATION RATE I 7; z- (minutes/inch) 72-©0£ (C/79) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, AnchoraB, e. Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST z~ $01L~; LOG PERCOLATION TEST PERFOR.ED FOR:. j. 2 3 4 7 9 10 11 'i-op WAS GROUND WATEi: ENCOUNTERED? SLOPE 12 IF YES, ATWHAT .~'~C¢.~.[ pA',/ DEPTH? SITE PLAN I I I I I j II I 14 15 16 17 18 19 Gross Net Depth to Net Reading Date Time Time Wa~er Drop ~ ~ ~:~ ~4~~c~" t l~" PERCOLATION RATE __A~7/ .i~_~.~.0 COMMENTS MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION E;25 L. Street, ·Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SOl LS LOG PERCOLATION TEST SLOPE SITE PLAN I I , ] Gross Net Depth to Reading Daze Time Time Waler Drop C O,',q M E NTS PERFORMED BY: CERTIFIED BY: .......... ~:~:, .a:.,~.~..~SOl/ · Pe~fc~med i"°r~~ence L~ Kilmer ~-~:~ Depzh S 2/5 g [/2 ~1/4 ~ 1/4 gg 1/4 o~ Sec 26 Bro~ clayey silt 1 (~) 3~ 4~ Bro~ silt S ~ (CL) 6 7~ 8~ Was O~ound Water Encoun~ez,,ed? no x~ 'if Yes, A~ ~'~.at %-%--- , ,~~.,~~~e r oedroom~ ' 'rest Perfo~¢~d ;y :~~,%¢~l~,sle /¢~: Data Certified 2y: National Testing Services Inc Date: ~"-- /, c o ~ 'r~ c~ ,e /,'VT.= 4 -92o ~ Well -7:/¢./ 'D E/q,I %/-/,2 '" [] SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 COMMENTS SLOPE SITE PLAN ~4- ~ NIlL HA~HORNE ~. ~ ~.. ...... . ~ w~:~~~ WAS GROUND WATER S IF YES. AT WHAT DEPTH? I I Gross Net Depth to Net Reading Date Time Time Water Drop ; ~/~ /'o~ ~ ~-~ ~ ~ ~ /; 32 30 g -3~ I / I PH ~ ~Pt-ts PERCOLATION RATE U ..~ t~* 4° Iminute'w'inchJ CERTIFIED BY: ~ DATE: PERFORMED 72-00g -~ ~ ~ SO!LS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST PERCOLATION TEST 4 10 11 12 13 14 15 16 17 18 19 SITE PLAN WAS GROUND WATER [~r;JJl~ , SL ENCOUNTERED? O E IF YES, AT WHAT 5E ~--,~ ~y DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop .¢/~o I; aS' 9- I¢ PERCOLATION RATE i7& :t TEST RUN BETWEEN ~ FT AND CERTIFIED BY: //~ (minutes/inch) 72.-O08 (6/79) 5~£E,' / : / ~0 - ~o ~ . -92o Well' "-- R/)-/, 2 7127 Old Seward N HAWTH O RNE-EN GINEERIN G July 29, 1983 N~'~',V~/TN(2RNE ~ ENGINEERING -¢2;? Cid Szward Highway Anch., AK 99.502 BOULEVARD ~ 99503 Mr. Robert Robinson Anchorage Municipality Department of Health & Environmental Protection 825 L Street Anchorage, Alaska 99501 RE: Judy Collier E½, NE~, NEb, SE~, Sec. 26, T13N, R3W, S.M. Dear Mr. Robinson, Please refer to your file on the subdivision of the above described property. Preliminary plat approval has been granted with two DHEP provisions. 1. Soils test on Lot 1 2. 90 day ground water level monitoring I am unsure why item one was required. Lot i has an existing house connected to a septic tank and crib shown on my original subdivision sketch. There is no visible breakout (water on surface) within a 50 foot or so radius of the crib. The crib is located a little over 90 feet from the dwelling's well. Please consider this my report on the ground water levels measured July 28, 1983. Lot 3 - T.H. I - Dry - Bottom of hole 14 feet Lot 4 - T.H. 2 - Dry - Bottom of hole 19 feet Lot 2 - T.H. 3 - Dry - Bottom of hole 19 feet Lot 3 is the one that had high ground water in May, supposedly because of a failed septic system nearby. That system's use was discontinued about July 1, 1983. Let me know your comments on item number one and if we need another ground water measurement next month. Thank yo~ / v '~leil HaWthorne, P.E. NH/rip 'I 00'~91 80'~19 ,~ ,,'~g .OO oO N f b~l-Z9d ,~ ,,fZb,OIoO N 0>z ~0 zO~ ~o~, ~ ~o~o' ~ <~ oz~~ ~<~ z~ ~<m<l ~zZZ ~o~ ><mo ~z~c ~0~0 Ww~ ~ wOw~ < ' 0 I ~wm- oz~l = ~ ~ ~ ~G J~mmv-_ · ~=> =~- o - ~lgo~°~xo~ -~= ~o~< ~ ~ =o o~=R~ ~ ~ ~o ~ ..... j~ ~ u, -~ I )~ ku :, / M~ -- J ~1 ~ ~ ~ .... I