HomeMy WebLinkAboutBIRCH TREE ESTATES BLK 1 LT 8 MUNICIPALITY OF ANCHORAGE I', ~.RTMENT OF HEALTH AND HUMAN SE[ .~ES Environmental Health Division 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Name/,t¢,¢~/.5 ....~--~ DISTANCES Address % TA~K FIELD WELL Phone(s) I Per~,t No. INo, of Bedrooms WELL ~?¢-/¢¢¢ J ~/¢~ 6 LOT LINE Township. Range, Section ~*~, ~'J ~ ~¢ dr,vewa., water bcd,es, etc., AS-BUILT DIAGRAM tShow ,coat,ce o, well, septic system, property ,,nas, ,oundat,on. TANKS i Man%lacturer Capacity in gallons Material No. of Compadments TYPE OF SYSTE~ ~TRENCH BED ~ W. DRAIN ~ OTHER or,ginalDepth tOgradep,pe bottom from ~- ~ FT Total depth from orig,nal~grade/~ Fill added above origma, grade / Gravel depth beneath pipe FT Total abs~rpbo, area /~ Distance between lines ~ ~'' i~' Sg FT FT .... , , Number of hnes Pipe material J Sod rating Installer Date Installed WELLS ~ ~ ~ PRIVATE ~ OTHER {Identify) ~% Classdicat,on (A,B,C} %oral Depth ~ Cased to /__ / Scale: · Inspections Pedormed by// Municipal and State guidelines in effect on this datE: 72-013 (3/85) ALASKA E FIUIROFImEFITAL COFITROL SERUICES, IFIC. (~nqinecrinq ~- I~nuironmenlal Studies Municipality of Anchorage Department of Health & Human Services 825 L Street Anchorage, AK. 99501 Attn: Dan Bolles Re: Lot 8, Block 1, Birchtree Estates Dear Dan: December 11, 1987 MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION RECEIVED On 10/30/87, a testhole was dri]led on the subject lot to monitor for ground water. See attached soil log. The testhole was drilled downslope of the existing bed. Ground water was encoutered at 8 feet, which would be 9 feet below the bottom of the bed. $otl was completely dry to 6 feet where it became slightly moist. The hole filled with water quite rapidly indicating an artesian pressure in the testhole. On 11/12/87 the water level was at 2.6 feet below ground surface, or 3.6 feet below the bed. You were on the site on 11/30/87 and found the water level at 2.8 feet below ground surface or 3 8 feet below the bed. ' · I believe these water monitor readings are inaccurate due to the artesian pressure showing a high static level. At worst case, I would say 6 feet below the surface, or 7 feet below the bed, would be a more accurate groundwater level which is where the soil showed some moisture content. We request that you approve the septic system on the subject lot. If you have any questions, please call. Sincerely, Alan C. Wien Engineering Technician 1200 LUest 33rd Auenue. Suite B · Anchoraqe. Alaska 99503.(907) 561-5040 Municipality of Anchorage Department of Health & Human Services 825 L Street Anchorage, AK. 99501 Attn: Mr. Dan Bolles, E.T. ALASKA erlUIROlqmellTAL COrlTROL $eRUICe$, (~n§incerin§ 6, (~nuironm~nt~l $1uclies Re: Lot 8, Block 1, Birchtree Estates Subdivision Dear Mr. Bolles: On December lOth, 1987, I visited the subject lot to look at the depression in the snow that you had previously discussed with Mr. Alan C. Wien. Morris Johnson showed me the area that you were talking about. I could see the area which was near where you had walked. The snow pack is heavy. I dug through at the locations shown on the attached sketch. With the heavy snow pack and the relatively mild winter coupled with the fact that the insulated shallow bed receives relatively warm water from the tank, there was no frost in the ground at the site where the depression was shown. The soils at that point were moist but not wet. From the measurements it would appear that this depression was very close to the edge of the bed. See sketch location 1. In the snow there are ice crystals from the ground surface to approximately 4 to 5 inches. This would indicate that the moisture coming from the ground is condensing and freezing in that range. At location 2 it is slightly decreased and at location 3 the crystal limit is about 1 to 2 inches from the ground surface. Also the ground at position 3 possibly had a frost right at the ground surface. However, it was not so deep that I could pentrate the ground surface just by taking my index finger and pushing it into the soil. I do not know if you have had the experience but whenever you have a heavy snow pack over a shallow bed you will get the 32 degree isotherm moving upward and fluctuating between the ground surface as much as a foot into the snow. This is evidenced by the evaporated water from the system moving up and then cooling to 32 degrees and crystalizing in the snow pack. As the winter goes on, if the snow pack continues the ice crystals will increase in size and in depth. By spring some of the crystals will be approximately 1/4 of an inch thick and may be as long as 1/2 of an inch. This phenomenon is not new. I have experienced it and reported it in the years since beds are being used in Anchorage. We know that evapotransporation does occur in shallow beds. Particularly in the winter there is evidence of evaporation of water and precipitating into the snow pack over top. You will also notice that in the spring the snow will disappear quicker over a bed than from the surrounding area. Because the 32 degree isotherm is at or above ground surface, some slight melting of snow will occur at the snow-soil interface. Therefore during the winter, unless there is a heavy period of extremely low temperatures, the ground over a bed will remain thawed. Since it is thawed and covered with a water bearing substance the soils will be slightly damp. 1200 LUesl 33rcl Ptuenue. Suile B ·/~nchoroqe. ~loska 99503.(907) 561-50/-10 I do not believe water is coming out of the lower part of this bed. If anything there might be less ground cover at that one point or the insulation did not completely cover the edge of the rock. Therefore, heat is escaping from that point faster than at other points. You might get one of the technical books on arctic engineering and check what I am saying. This is a common phenomenon which most engineers who work in cold climates have seen and experienced. It is nothing to be alarmed about. If you have any questions, please give me a call. Sincerely, Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: ,~ ~'~/-~' LEGAL DESCRIPTION: ,~"' -~?J / 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O I'El 'TI :E E't') ~./~) SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? s IF YES, AT WHAT ~ O DEPTH? o p E Depth to Water AIter__,a~. Monitoring? ~ Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE __ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FT AND FT PERFORMED BY: '~'~-~'~'~ '~ I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: //~ ~ ~°~ 7 ALASKA ENVIRONMENTAL CONTROL SERVICES, INC. 1200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) 561-5040 SHEET NO. CALCULATED BY CHECKED BY SCALE / oF DATE DATE .... AIX~CHORAGrz, ALASKA r. 64-41 ! 1 TOH v a ,x,,C, WL ES DEPARTMENT OF HEALTH & HUMAN SERVICES January 10, 1986 TO: Permit Applicant Subject: Permit # 850148 Lot 8 Block 1 Birch Tree Estates Subdivision A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1985. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be Obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspec.ted the installation of the on-site sewer system the original as-built inspection report(three part form) must be sent to this office for review and approval,and for documentation. If there are any further questions, please call this office at 264-4720. Sincerely, Susan E. Oswalt Program Manager On-site Services SEO/ljw enc: Copy of Permit C E)N T A C'I" P H 0 N E: :: M 0 R R :!: S J CIH N S 0 N :1.200 :!: ST'I:~E:E::T :I:F~I. :l.'.:} 278'.." 1 {366 ~'~' ...... ~" ... .tuv ~" ;'" ;~ '~ " ... ' ....,I L '., by th,-"::, Municil::)at"'"',' ,::)F Anchc)r'a;.::.!,::.', (~..,~ , .::,.r"~d '.:h,:':, !::-', t .,,: t ;::., c;~. A'las~.:'.'::,,, 2, I w.:i.].t ins'La11 'Lhe sy.:H:..em :i.p. a,::::cc)r'dar'~c:e w:'Lh a].l MC)A c: ci d ,:::.! :::i ,::.:,.r"~d ar'id :i.n comp 1 :i..:::nce :,,~:i.'k.l": the dEi'5:::i.m:::jn (:::P :i.t(:.TzP :i..;::i. O{:' th :i.:::: per'mit. 3, ].' J,,J:i.!]..::'J. dh(:.:.?r'e '{:.c) .:::,.] ]. MOA ...':..',. r'~ ,.'::l Stat,::.:, ,::::,.F :::::::::::::::::::::: r,,:.:.?ciu.:i.r, eh'¥iE!r':'l:.,..::: .For' tl"~,::.:-~ '..~,u::.::,'L i:::::~: k d :i. '.;!:i-'L.:'..':I"iC::E.)E.."... {' I"'C:)YTi ,::).i"iy E:.:,F': :i. ::..:'J_'. :i. i'],:::j m.'.a':, ]. ], was'-:.'E:.E~i~.Ja'L.,::,r' (::~ i ::.'_: p c) .::h:: ]. syst,:.:.)A': oP F:,u.b ]. :i. s ,:.:.::, w ,::::, r' .:::: {::j ,.':e :::::::::::::::::::::: ,::::,r": 'l.'..h:i.:::: c,r' any acl.:ja,:::E!r'.,t c)r' J'"i(.--'.:)apJ:)y :{. C:)'{:. ,, ...........................TF A ...... 1.1"' , <::,r:...: .t.[.]l,l :1: :rI,,IF;"I"AI I F::T} IN AN :..-...:" ' -" ,,:::. :..: r:- ,,'.i V F:r ::. !:::. i..) ::.,v MFIA /::,; .... t...)::)]:NE:i ........ bl.::., :. T'HI:i:N (.1.) AN I:.L.J ..... ! r~ ., (.. (.d .... I:::' :::' :~1'~ '1' "1" AND :l:i'<"'r''' ........... ,,, ,. ...... r.,...,....,.,..~, ..., ... l ........ ...... ::x... t:::.C ! :1: (::!i"-,l [ hJ.:::~ I BI::: ,..h.., I ~...: l.,h....L, :, fi:..'..t ) ,,:.:: !::: -.. F~ ~'1 .... <::-' l,d TI mi .... N[)'I" 'E,'E::,-~ . ........ r-, .....r~ i:,t:::'i:::,r:m::,"", /'.,1~:',"~ ~ ":' ........ ' "' ,..'..., v :.,..~ W I 'T'HOLFI" Afl. ,....,_.,.......,:'~ :'~ ........, ~:, I C:At .... :I: NSF::'E:C::]" I ON .......... :, :...< ............. ) ]"HE!: F'I. I:::'CTF:~ !' CAI .... ~ r'u::;'l.:' .,j..::" ..... ~.:'qi:!: :OE!I'.,IE BY A L...~.L,I:::.I,I.:::.,:::.~..,' ...., ,..,.'.. ,..: i:::, :::.~ ....... ::.. !:C:!: "': ...... :, ,E:: ..... : ........................................................................................................................................................... ,, .'. r.' M,.::) R R :I: .:::: ,.:! ::)H l~d) N ' ...,I , L. :1: CANT,: :1: SSL!I::::):) BY ALASKA e LIIROFIm( FITAL COI'ITROL II'lC. E,qi,ee~'inq g- (~nuironmental Studies SPECIFICATIONS FOR BED WASTEWATER TREATMENT SYSTEM - Lot 8, Block 1, Subdivision: Birchtree Estates 1.0 GENERAL 1.1 THE DRAWINGS, SHEETS 1 THRU 5, SHALL BE PART OF THIS SPECIFICATION. 1.2 ALL MATERIALS AND WORKMANSHIP SHALL MEET THE REQUIREMENTS OF THE MUNICIPALITY OF ANCHORAGE, DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION (DHEP), THE CONDITIONS OF THE PERMIT, AND ALL APPLICABLE RULES AND REGULATIONS CURRENTLY IN EFFECT. 1.3 ALL EXCAVATIONS AND DEPTHS ARE ADVISORY, AND ARE TO BE VERIFIED OR MODIFIED IN THE FIELD BY A DHEP APPROVED INSPECTOR. 1.4 IT IS THE RESPONSIBILITY OF THE INSTALLER TO ADHERE TO APPROVED DESIGNS FOR INSTALLATION, TO MAIN- TAIN THE SPECIFIED SEPARATION DISTANCES, AND TO HAVE THE APPROPRIATE INSPECTIONS. 1.5 IF THE INSTALLATION IS NOT INSPECTED BY AN AECS ENGINEER, AECS WILL NOT BE RESPONSIBLE FOR THE DESIGN. AN ENGINEER AT AECS SHOULD BE CONSULTED PRIOR TO CONSTRUCTION, TO DETERMINE THE NUMBER OF INSPECTIONS THAT WILL BE REQUIRED AND TO EXPLAIN ,,,,./~ ,~ ~/~ ~./.~._ WHAT THESE INSPECTIONS WILL INVOLVE. //?~L/~.f~.~~'~J_.. THE SEPTIC TANK SHALL BE A UPC-APPROVED TWO-CO ARTMENZ , --' TANK, CONSTRUCTED OF 12-GAUGE STEEL WITH BITUMASTIC ,, ~--~> f /~ COATING, SET LEVEL ON UNDISTURBED SOIL, AND INSULATED WITH AN OVERLYING LAYER OF 2 INCH BURIAL TYPE POLYSTYRENE. 2.2 THE SEPTIC TANK SHALL BE A MINIMUM OF 5 FEET FROM THE HOUSE FOUNDATION, AND A MINIMUM OF 5 FEET FROM THE ABSORPTION AREA. 2.3 THE SEPTIC TANK AND BED SHALL BE A MINIMUM OF 100 FT. FROM ANY PRIVATE WELL OR BODY OF WATER, 150 FEET FROM CLASS C WELLS, AND 200 FEET FROM CLASS A OR B WELLS, UNLESS OTHERWISE SPECIFIED. LESS THAN THE REQUIRED SEPARATION DISTANCE MUST HAVE PRIOR APPROVAL OR WAIVER BY ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION (ADEC). 1200 tUest 33rd Auenue. Suite [~ · Anchora§e. Alaska 99503 e(907) 561-5040 2.4 PIPING SHALL BE FITTED WITH A MECHANICAL WATERTIGHT CALDER COUPLING ON THE OUTLET AND INLET OF THE SEPTIC TANK. PIPING SHALL BE 4-INCH SOLID PVC ASTM D3034 OR CAST IRON, SLOPED A MINIMUM OF 1/4" PER FOOT WITH A MINIMUM OF 4 FEET OF COVER. 2.5 CLEANOUTS SHALL BE INSTALLED AS DESIGNATED AND CAPPED WITH AIR-TIGHT RAIN CAPS (JIM CAPS OR EQUIVALENT), AND EXTEND A MINIMUM OF 2 FEET ABOVE GROUND LEVEL. 3.0 SEEPAGE BED 3.1 THE GRAVEL FOR THE BED SHALL BE 0.5 TO 2.5 INCH, SCREENED ROCK WITH LESS THAN 3% PASSING #200 SIEVE RESIDUAL. ALL SUBSTITUTES MUST HAVE PRIOR DHEP APPROVAL. 3.2 THE BOTTOM OF THE EXCAVATION SHALL BE LEVEL AND RAKED WITH THE BACKHOE BLADE TO INSURE THAT THE BOTTOM HAS NOT BEEN COMPACTED DURING EXCAVATION. 3.3 THE DISTRIBUTION PIPE SHALL BE 4-INCH RIGID PVC WITH A MINIMUM CRUSH STRENGTH OF 1500 LBS. ALL PIPES SHALL BE LAID LEVEL, AND SPACED ACCORDING TO THE DRAWINGS. 3.4 TWO MONITOR STANDPIPES SHALL BE PLACED AS SHOWN IN THE DRAWINGS. THEY SHALL BE RIGID PVC ASTM D-3034, OR 4" DIAMETER CAST IRON. THE SECTION SHOWN WITH HOLES MAY BE EITHER DRILLED 0.5" HOLES ON THE 6 INCH CENTERS ON OPPOSITE SIDES OF THE PIPE, OR A SECTION OF REGULAR PERFORATED SEWER PIPE MAY BE CLAMPED TO THE SOLID SECTION WITH A NO-HUB COUPLING OR SOLVENT JOINT. A RUBBER RAINCAP (JIM CAP OR EQUIVALENT) SHALL BE PLACED OVER THE TOP OF THE PIPE. 3.5 IF THE FINAL GRADE OVER THE BED IS LESS THAN 4 FEET ABOVE THE GRAVEL, INSULATION IS REQUIRED, USING DOW EXTRUDED BLUE STYROFOAM BOARD. THERE SHALL BE 1" OF INSULATION FOR EVERY FOOT OF SOIL LESS THAN THE REQUIRED 4 FEET OF COVER, BUT THERE MUST BE AT LEAST 18" OF SOIL EVEN THOUGH INSULATION IS USED. THE SOLID PIPE EXTENDING FROM THE SEPTIC TANK TO THE DRAINFIELD SHALL ALSO HAVE 4 FEET OF COVER OR AN EQUIVALENT LAYER OF INSULATION COMBINED WITH SOIL TO PREVENT FREEZING OF THE LINE. 3.6 IF INSULATION IS NOT NECESSARY, THEN THE GRAVEL MUST BE COVERED WITH A LAYER OF A NONWOVEN FABRIC (SUCH AS MIRAFAI, FIBRETEX 200 GRADE, POLY-FILTER X, OR EQUIVALENT). 3.7 THE TOP AND SIDES OF THE BED SHALL BE PLANTED WITH A WHITE CLOVER AND RED FESCUE MIX OR BLUE GRASS. ALASKA ENVIRONr 'NTAL CONTROL SERVICL , INC. 1200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) 561-5040 JOB SHEET NQ CALCULATED BY CHECKED BY SCALE t"~ DATE &,r. vv T~'~L ~?,~lt,.i P~V~IILJIg, OUI~ ~ ~ -'- '-~ DATE -.~/ ~' / ' ~ ANCHORAGE, A~SKA 99503 / / ' (907) ~1-~0 C,Ec~t~ e~ ~, ............... ; ............. ; ........... ~ ................. ~ .............. , .............. ~ ........... ~ ......................... ~ ............ ~ ........... ~~ i ,~ ............ ~ ............. ~ ............. ~ ...................... : ............................................. ........... ~ .~ ............ ~.~ .......................... ~ ...... m~.~.~ ........... ~ .................................................................. ~ ............ ~  ~ [ ' ~ ~ ..... ~ ............. ~ ............. i ........................................... [ ~ ,~ .............. ,i ............. ~ .......................................... ~ .................................... : .......... ; .................... ; .~ ............. ~ .........~ ............ ~' ............ i' ~ ~ ~ ~ ~ ~.  ~ ~ ~ ~ ~ ...... ................ ~ ~ ..... ~ ..... ~ ..................................................... _ ~': .............. ~ ~ .......... ~ ....................... ~ ~ ......................... ~ ..................... ~ .......... .................................... ........................................ : ...... ........ J .......... ~ ................. 1 ............ i ............ ~ ~ ........... ~ ............ ~ .............. ~ .............. ~ ......................... ~ .......... ..................... ~ ........................................ ~ ............. ~ ........ ~'~ ....... ~ ............. ~ ............ ~ ............. ~ ....................... [ .............. ~ ~ ~ .............................. : ........ ~...~.~, ............. ~ ..................................... : ............. ~ ~ ~. ~ , : ~ ................ ~ ........................... ~ . ~ ~ ~ ..... ~ ..... ~ ................. ~.j~;~,..: ............ ~ ..................... i ~ ~ ~ ~ ~ ......... r ............................... : .......... .......... x ........... ; ............ 1 ........... ~ ....... ~ ............ ~ ........... ~ ~ i ...... ~ ....................... ~ ............ : ........... ~ ..................................................... ............ ~ ............. ! ............. ~ .............. J .............. ~ ........ ~ ~ . ......... ~ ............ ~ ............. i ~ ~ ~ i : -* ~ ........... ~ .............. ~ ...... . . , ......... , ................................. .................. ~ ............. ~ .......... ~ .............................. ~ .., ........... ~ ......... j ........ ~,. ~ : i ~ ~ - /;. ~ . ~ i ...... ~ ........................ ' ................. ~ .......... [ ................................ ; ............ ~ .....~ ........ ~ ............ : ....... ; .............. ..... :; ...................... ; : ........... , .................... ~ ........ , ..................~ ..................... : t .... ~ .... ~ .......... ? 't .......... t ..... ~'*' ~ ....................................................... .: ................................................................................................... , .l~g . . , , ALASKA ENVIRONr'*-~ITAL CONTROL SERVIC INC. 1200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) 561-5040 JOB ,0 ;~ ~-/'r~ SHEET NO CALCULATED BY "~;~'~'~'7 CHECKED BY ~ SCALE ~ ~ [4:::)' DATE o 0 !. _i' ~o . ,4 ~/~ ,-,'%'W-~'""-'F eot O~OG'Tgs (106) £0§66 ¥~1SV9¥ '39¥~IOHC)N¥ B m,!ns 'enue^¥ p~$£ ~,seM 00~ ! 'ONI '-'IOlAB=IS 90B.I. NO0 'IVJ. N_~NOBIAN;! VMSVqY ALASKA ENVIRONMENTAL CONTROL SERVICI' INC. ! 200 West 33rd Avenu, ,uite B ANCHORAGE, ALASKA 99503 (907) 56[-5040 SHEET NO. OF CALCULATED BY ~ A ' DATE CHECKED BY ~ DATE SCALE ~ f'' LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST z*~-----"P E R CO LATI O N TEST PERFORMED FOR: LEGAL DESCRIPTION: DATE PERFORMED: 20 COMMENTS PERFORMED 72-008 (6/79) SLOPE SITE PLAN WAS GROUND WATER E~COUNTERED? IF YES, AT WHAT DEPT.? Gross Net Depth to Net Reading Date Time Time Water Drop ~ )~ ~o .~.-~ ,o ~ 4 lo~ F o 'Vq ,o s- PER(~)LATION RATE '3 I ~C~'~'~ (minute~Ti~ch) TEST RUN BETWEEN ~ FT AND ~" ~¢~'" FT ~o~~~ CE}TIFIED BY:' l ~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SOILS LOG PERCOLATION TEST PERFORMED FOR: t~J~ 0 ~'r"'~ ~..Tc~n .~ 6/.7 DATE PEREORMED: LEGAL DESCRIPTION: Bir--r_.h'f£¢~ ~----c~'~L°:~'~& B)o~/c I Lo1-e~ SLOPE em.o SITE PLAN 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O COMMENTS PERFORMED BY: '~ar~..~ ) WAS GROUND WATER S ENCOUNTERED? ~ ~ L O P IF YES, AT WHAT d''" S/t~/~' DEPTH? ~'~517-4 ]~'~ Reading Date Gross Net Depth to Net Time Time Water Drop l o q z i o ,,5-3 .o~ 2- io $" z ,)- ,::? · o .3 PERCOLATION RATE TEST RUN BETWEEN ~'~ FT AND --2 a/7.-- FT CERTIFIED BY: DATE: (minutes/in~;h~ ~' · 0 ~ 72-008 (6/79) ALASKA ENVIRONNI. FNTAL CONTROL SERVIC. INC. 1200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) 56].-5040 SHEET NO CALCULATED BY OF CHECKED BY SCALE //$ '~ 0 DATE \ ................. ; \ .: ........ ~...~"i;;~''''~ ................ : ' .... iiii'i"ii'iiii'iiiii"iiiiii'i"iii" i .................... /i. iiiii.' .ALASKA ellUIROrlmt~rlTAL COKITROL $t~RUICI~S" IrlC. J~nljine~rin~j [ J~nuJronm~ntaJ $11Jdi~s PERCOLATION TEST DATA SHEET CLIENT ADDRESS DATE ZIP CODE LEGAL LOCATION t~,r'~qc~ TOTAL DEPTH OF HOLE ZONE TESTED ft. ft TO .2., ft READING # CLOCK TIME NET TIME DEPTH TO NET DROP RATE (min/in) DATUM to'Il l OJ.-t FINAL PERCOLATION RATE PERFORMED BY 2'/I J tc~ %~l -~ 2.06 {min/in) t2oo JJU~st 3$rd Auenu¢. Sui,t,J~' Anc~raqe. Alaska gg~o3 · (907) 276-1361 ALASKA ENVIRONMENTAL CONTROL SERVICES, INC. 1200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) 561-5040 SHEET NO. // OF ¢ CA'CUL*TEDSY tk ~i/~A DATE !1' :-- ~:' CHECKED BY DATE SCALE ALASKA ENVIRONMENTAL CONTROL SERVICES, INC. 1200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) 561-5040 SHEET NO. CALCULATED BY CHECKED BY, OF DATE SCALE ALASKA ENVIRONMENTAL CONTROL SERVICES, INC. ! 200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) §6~.-§040 JOB SHEET CHECKED BY DATE sCALE /; la ........... ~ ..... ~..¢....~ ~ ~.,,~r.~. ~ ? ALASKA ENVIRONMENTAL CONTROL SERVICES, INC. 1200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) 561-5040 CHECKED BY DATE ~p~ CN>1 (907) 243-2282 KEN JOHNSON KEN'S COMPANY WATER WELL DRILLING PUMP SALES & SERVICE 30 YEARS ALASKA DRILLING 3163 LINDEN DRIVE ANCHORAGE, ALASKA 99502 ~or ~is Johnson 1200 I Street, ,~ 410 Anchorage, Ala~ka RE~ BIRCH TREE E'~TA~ES LO£ 8 BLK. 1 ( 278-1866 ) 0 ft to 2 ft 2 ft to ~ ft 9 ft to 14 ft 14 ft to 32 ft 32 ft to 34 ft 34 ft to 36 ft 36 ft to 37 ft 37 ft to 39 ft 39 ft to 44 ft 44 ft to 51 ft 51 ft to 57 ft 57 ft to 59 ft 59 ft to 96 ft 96 ft to 101 ft 101 ft to 104 ft 104 ft to 107 ft 107 ft to 209 ft TO~AL CASING 110 ft !0~ in. 0rga,nic peat .~.o~ Course gravel & gray silt .,,~ ~ed. Erav & ~ray silt ~' Boulder ~ ~ \~ CourBe gray & ~ray silt i, ~.~ Boulder Cobbles & course gray Course gray & gray silt aame with finer gray Med gray & light Brown silt Boulder Course gray & gray silt Brown silt & fine gray Same (weeps) 11 ft. head bails down Same ( dry ) Med gray & sand.. Water bearing Test bailed at 10 GPM 21 ft head 4 ft drawdown..., good recovery Bottom stable ...very clean TEST PUM~ DATA. July 16, 1985 Static Water Level 90.5 ft ( TOC ) T I~E G.Pi~I DRA~'~DO WN RE~qKS 1900 9 94 light dirty 192 0 14 97 · 5 cloudy 1945 14 98 Clean & clear 2000 14 98 " Good recovery Pump set at 105 ft 10 in from top of casing ( TOC ) ~'~,~s ~o ~o TODAY 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O 91-009(3/76) urdcip . tYof Anchorage P.O ')X 196650 ANCHORAGE, ALASKA 99519-6650 (907) 264-4111 TONY KNOWLES, MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES March 25, 1987 Dr. Leroy C. Reid 1200 West 33 Ave., Suite B Anchorage, Ak. 99503 Dr. Reid, On November 25, 1987 a letter was sent to your office concerning the disapproval of a septic system on Lot 8 Blk 1 Birchtree Est. On that same day I discussed the matter with the owner, Mr. Morris Johnson. It was agreed, at that time, to hold the as-built and HAA until a meeting could be arranged with your office. However, to date Mr. Johnson has not contacted this office for such a meeting. I am, therefore, returning both the as-built and HAA to your office along with a copy of the previous letter. Should Mr. Johnson or your office wish to give further consideration to the matter please don't hesitate to contact me at 343-4744. Sincerely, Daniel N. Bolles Eng. Tech. III DHHS MUNICIPALITY OF ANCHORAGE DEPARTI~, ,T OF HEALTH AND ENVIRONMENTAL I, ,,TECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SiTE SEWER AND WATER FACILITY 264-4720 Application Date GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) . (b) Location (address or directions) Applicant"Name Telephone: Home Business (c) Applicant Address /,Z¢-~ .~ ~'7~ .~*'/~ ~/~ ,/~/~./ /~' Applicant is (check one): Lending Institution [] · Owner/builder~'; Buyer []; Other [] (explain); (d) Lending Institution Address (e) Real Estate Company and Agent Address Telephone (f) Mail the HAA to the following address: Telephone TYPE OF RESIDENCE Single-Family'S' Multi-Family [] Number of Bedrooms -~ Other WATER SUPPLY Individual Well,~ Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. SEWAGE DISPOSAL Onsite~, Public [] Community [] Holding Tank Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 (11,84) 5. ENGINEERING FIRM PROVIDI, INSPECTIONS, TESTS, FILE SEARCH, C ,A AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection.,~. Name of Firm ~~ Telephone Address /~'0 /~ ~]~ Date App~uvud ;'u., ------'---' bedrooms by ~ Disapproved ~ ........... Terms of Conditional Approval Date CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (11/84) MunicipalitYo Anchorage P.O. BC,, 196650 ANCHORAGE, ALASKA 99519-6650 (907) 264'~k1~txx 4744 TONY KNOWLES, MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES On-site Services, Room 502 November 21, 1986 Mr. Jeff Kaitchuck 1200 West 33 Avenue Suite B Anchorage, Alaska 99503 Subject: Morris Jo~nsen Property Lot 8 Block 1 Birch Tree Estates Subdivision Dear Mr. Kaitchuck: The Health Authority and as-built received by this office, concerntngf: the subject lot, have been disapproved for the following reasons: There exists, downslope of the septic system and between Lots 8, 9 and 11 a drainage ditch. This drainage serves to transport both surface and ground water encountered due to the excavation. Per Alaska Stature 18 ACC 72 and AMC 15.65.040 I; and .060 B this would require a minimum 100 foot separation from the septic system. The possibility of a waiver in such an instance could not be issued without suitable precautions being taken (AMC 15.65.020 A-C and .150 A-C). e The presence of a small stream of water between Lots 8 and 7 which is glaciating across the driveway and around the well, raised the possibility of contamination of the water supply by surface runoff. e The presence of numerous outbreaks of water around the residence and septic system indicates possibly that the seasonally high water table is less then the -5 foot which was noted in March and June of 1985. Per AMC 15.65.020 C 6; 040 F; and .060 A3 this would have to be determined. As these facts were not considered in the design and permit process for the subject lot we cannot authorize the use of the on-site system installed, Mr. Jeff Kaitchuck, A.~E.C.S, Inc. November 21, 1986 Page Two Whereas your office designed and inspected the installation we would like to have your input, so as to solve this problem as quickly as possible. Please feel free to contact my office at any time for further clarification. S in c~.r ely ,,~ Daniel N. Bolles Engineering Tech On-site Services DNB/lJw 5&unicipality P.O. dOX 196650 ANCHORAGE, ALASKA 99519-6650 (907) 264-,t:td~ 4744 TONY KNOWLES, MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES On-site Services, Room 502 November 21, 1986 Mr. Morris Johnson 1200 I Street, Suite 410 Anchorage, Alaska 99501 Subject: Lot 8 Block 1 Birch Tree Estates Subdivision Dear Mr. Johnson: After careful examination of all available information and following an in-field investigation, I regret to inform you that in the opinion of this department the septic system constructed on your property is not in compliance with existing State and Municipal Codes. Per Alaska Statute 18 AAC 72 and AMC 15.65.060 B1, the existance of an on-site septic system within 100 feet of surface water is not permitted. The existance of water bearing ditches constructed along the western and southern boundaries of your property would preclude the site selected for on-site disposal. There also exists concern over possible encroachment on the four foot separation required by AMC 15.65.020 C between the base of the seepage bed and ground water, as well as the possible contamination of your well by surface water runoff. I would like to discuss this matter as soon as possible and would suggest both you and your engineer be present to go over our findings. Please call me for any further clarification you might need at 264-4744. Sinc~erely,, ~ Daniel N. Bolles Engineering Tech On-site Services DNB/lJw unicip ityof nchor ¢ P.O. BOX 196650 ~--'~ .... ANCHORAGE, ALASKA 99519-6650 (907) 264=¢k1~o~1x× 4744 TONY KNOWLES, MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES On-site Services, Room 502 November 21, 1986 Mr. Jeff Kaitchuck A.E.C.S., Inc. 1200 West 33 Avenue Suite B Anchorage, Alaska 99503 Subject: Morris JoWnmem Property Lot 8 Block 1 Birch Tree Estates Subdivision Dear Mr. Kaitchuck: The Health Authority and as-built received by this office, concerning.: the subject lot, have been disapproved for the following reasons: There exists, downslope of the septic system and between Lots 8, 9 and 11 a drainage ditch. This drainage serves to transport both surface and ground water encountered due to the excavation. Per Alaska Stature 18 ACC 72 and AMC 15.65.040 I; and .060 B this would require a minimum 100 foot separation from the septic system. The possibility of a waiver in such an instance could not be issued without suitable precautions being taken (AMC 15.65.020 A-C and · 150 A-C). me The presence of a small stream of water between Lots 8 and 7 which is glaciating across the driveway and around the well, raised the possibility of contamination of the water supply by surface runoff. The presence of numerous outbreaks of water around the residence and septic system indicates possibly that the seasonally high water table is less then the -5 foot which was noted in March and June of 1985. Per AMC 15.65.020 C 6; 040 F; and .060 A3 this would have to be determined. As these facts were not considered in the design and permit process for the subject lot we cannot authorize the use of the on-site system installed¢ P 1,26 633 041 RECEIPT FOR CERTIFIED MAIL /-NSq~SURANCE COVERAGE PROVIDED ( N0~R INTERNATIONAL MAIL \ '~eeReverse) S et d No Mr. Jeff Kaitchuck, A.E.C.S, Inc. November 21, 1986 Page Two Whereas your office designed and inspected the installation we would like to have your input, so as to solve this problem as quickly as possible. Please feel free to contact my office at any time for further clarification. Sinc e_.r ely ,~ ~,~,, Daniel N. Bolles Engineering Tech On-site Services DNB/ljw f (907) 243-2282 KEN JOHNSON KEN'S COMPANY WATER WELL DRILLING PUMP SALES & SERVICE 30 YEARS ALASKA DRILLING 3163 LINDEN DRIVE ANCHORAGE, ALASKA 99502 JULY 16, 1985 Morris Johnmon 1200 .IS.treet # 410 Anchorage, Alaska 99501 RE, BIROH TREE .ESTATES LOT 8 BLK. I ( 278- 866 ) 0 ft to 2 ft 2 ft to) ft 9 ft to 14 ft 14 ft to 32 ft 32 ft to 34 ft 34 ft to 36 ft 36 ft to 37 ft 37 ft to 39 ft 39 ft to 44 ft ft to 51 ft 5i ft to 57 ft 57 ft to 59 ft 59 ft to 96 ft 96 ft to 101 ft 101 ft to 104 ft 104 ft to 107 ft i07 ft to 109 ft TO~AL CASING 110 ft 10½ in. Fill Organic peat Courme gravel & gray silt Med, gray & gray silt Boulder Course grav& gray silt Boulder ~bbles & course'grav Course grav& gray silt ~ame with finer gray Med grav& light Brown silt Boulder Course grav & gray silt Brown silt & fine grav Same (weeps) 11 ft. head bails down Same ( dry ) Med grav& sand.. Water bearing Test bailed at 10 GPM 21 ft head 4 ft drawdown..., good recovery Bottom stable ...very clean TEST PUMP DATA, July 16, 1985 Static Water Level 90.5 ft ( T0C ) TIME GPM DRAWDOWN REMARKS 1900 9 94 light dirty 1920 14 97.5 cloudy 1945 14 98 Clean & clear 2000 14 98 " " Good recovery Pump set at 105 ft 10 in from top of casing ( T0C ) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PhuTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) . Location (address or directions) (b)' Appl;can(Name ~J'~¢~/~'$ ~)~',~t''v/ Telephone:Home ~-/r~¢ Business (c) ApPlicant is'(check one~: Lending Institution D' Owner/builder~; Buyer B' Other D (explain); (d) Lending Institution ~ Telephone Address (e) Real Estate Company and Agent · Address Telephone (f) Mail the HAA to the following address: TYPE OF RESIDENCE single-Family~j~ Multi-Family [] Number of Bedrooms -~ Other WATER SUPPLY Individual Well,~ Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite~ Public [] Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 72-025 (11/84) Page 1 of 2 ENGINEERING FIRM PROVIDIN~ ~NSPECTIONS, TESTS, FILE SEARCH, DA,., AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Address /~'~'~ ~J Date Telephone Apl~,uvud [u, "'-'"----- bedrooms by ,,¢~FprO~"8 Disapproved ~ -Cond:,t:,o,'~', ~ Date Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (11/84) WELL DATA Well Classification , Well Log PresentON) Total Depth Static Water Level Casing Height Above Ground ElectriCa Wiring in Conduit (~'~) Separation Distances from Well: To.Septic/Holding Tank on Lot MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST- FEBRUARY 1984 264-4720 Legal Description: DL=Pr. O~ Nr~N. TN & NOV !-~ 1986 If A, B, C, D.E.C. Approved (Y/N) "/"16' $~" Yield Date Com/pleted Cased to /~ Depth of Grouting ~'0, ~ · Pump Set At /,.<" g~ Sanitary Seal on Casin ) Depression Around Wellhead (Y~) ..~To Nearest Edge of Absorption Field on Lot /j7.~¢ / To Nearest Public Sewer Line ~.J,/~', .,,'~ To Nearest Public Sewer Clean out/Manhole ~,/'//~ To Nearest Sewer Service Line on Lot Water Sample Collected by ,~"~-~ (,.~, K~'~ 'rc~oC...~ ) 'Date Water SamCe Test Results _ ,5/)* 7'/% F AC,~O~' ~' · On Adjoining Lots On Adjoining Lots Comments B. SEPTIC/HOLDING TANK DA'rA Date Installed StandpipeON) ,~. Air-tight Caps(~N) Depression over Tank (Y/N)) Pumping/Maintenance Contract on File (Y/N),/. Holding Tank High-Water Alarm (Y/N) ,~//,,"'¢ Separation Distances from Septic/Holding Tank: To Water-Supply Well /O13 To Property Line ~ To Water Main/Service Line _ Course Size ,/~"~ff ~ No. of Compartments ~ Foundation Cteanout("~N) Date Last Pumped ,~,~ ; for ,~,,'~ Temporary Holding Tank Permit (Y/N) To Building Foundation To Disposal Field To Stream, Pond, Lake, or Major Drainage Comments Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field Type of System Design ~"~ Length of Field ~O / Depth of Field Gravel Bed Thickness ¢~" ''~ Standpipes Present(~) Date of Last Adequacy Test Square Feet of Absorption Area Depression over Field (YN~ Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well To Building Foundation Lot ~///,~ To Water Main/Service Line ! /,7--'~/ To Property Line To Existing or Abandoned System on ; On Adjoining Lots To Cutbank (if present) To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments LIFT STATION / / Dat'~eln t , )ate~ Dimensions S_ize in ?aliens ~ Manhole/Access(Y/N) _ "Purn.p On'' Level at ~ "Pump Off" Level at _ High Water Alarm Level at -"'-~~Vent (Y/N) _ Test_ ed for __ P~ during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that,~_______.~/,~,/,~.~conformed to all MOA and HAA guidelines in e f fo ct on the date of this inspection. Signed Date Company /'~'~ MOA No. Receipt Date of Payment-' Amount: $ Page 2 of 2 72-026 (11/84) JML INC. LAB0~ )RV 1.0. # 7127 OLD SEWARD HIGH%,,,~' ..... ANCHORAGE, ALASKA 99518 (907)344-8551 BACTERIOLOGICAL WATER ANALYSIS TO BE COMPLETED BY WATER SUPPLIER .... TIME COLLECTED I TYPE OF SYSTEM AMJ [~ PUBLIC. INDIVIDUAL [] r. TRCLE CLASS TELEPHONE NUMBER II)ATE COLLECTED ' I mNTH ~Y YEA~ ! I.D. NO. (pUBLIC SYSTEMS) I,' ' . , I I ,I NAME OF SYSTEM SYSTEM ADDRESS CITY STATE 'LOCATION WHERE SAMPLE WAS COLLECTED COLLECTED BY:(SIGNATURE) /% z:/?~-~ ~.! // L] / ~'/.-','..-~..L .... 1"'; ..... - i,~',/ ~, ZIP CODE TYPE OF SAMPLE (CHECK ONLY ONE THIS COLUMN) rI~DRINKING WATER v~'CHECK TREATMENT [] RAW SOURCE WATER [] NEW CONSTRUCTION OR REPAIRS [] OTHER(Specify) [~CHLORINATED [:]FILTERED ~tJNTREATED OR OTHER IS THIS SAMPLE A CHECK SAMPLE TO A PREVIOUS NON-CONFORMING SAMPLE? [:]YES ~NO PREVIOUS COLLECTION DATE ANALYSIS REQUESTED (IF OTHER THAN TOTAL COLIFORM) "'~'~D REPORT TO:(PRINT FULL NAME,ADDRESS AND ZIP CODE , _~. ~ I,J~/~- ,i~OR LAB USE ONlY L RESUBMIT SAMPLE Sanq)le! rejected because: CHECK ONE OR HORE r-1Sa~le too long in transit. Sanmle should not be over 30 hours. ['l Sanq)le received too late in week [] Not in proper container [:3Leaked: out [] Insufficient information provided. Please read instructions on form. []Other (Specify) RECEIVED FROM ,l? RECEIVED ~Y t ~l':( p[ m ANALYTICAL METHOD: ~EMB~NE FILTER [] FERMENTATION TUBE Date & Time Started Date & Time Completed 1~-'~? LABORATORY RESULTS Analyst ,,._J~77'2 £'~. ,-~ ~r...,x~ [] Other Bacteria ~3 Test unsuitable because: [] Confluent Growth [] TNTC SATISFACTORY [] UNSATISFACT(N~Y [] BACTERIOLOGICAL WATER ANALYSIS RECORD FOR LAB USE ONLY OTHER Membrane Filter: Direct Count .... Verification: LTB Final Membrane Filter Results Reported By BGB Date Coliform/lOOml Coliform/1OOml Time A.M, READ SAMPLE COLLECTION INSTRUCTIONS ON BACK OF FORM