Onsite File Birch Tree Estates Block 2 Lot 2 #017-141-34 Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191264 PID Number: 017-141-34 Dwelling: Q Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑ Upgrade Name: Martin & Christine Scally ABSORPTION FIELD F-1 Deep Trench ❑Shallow Trench ❑Bed ❑ Mound Address 3705 Arctic Blvd. #280 Anchorage, AK 99516 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 242-9454 3 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot Birch Tree Estates 2 2 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From ( Tank Field Tank Line Ft Ft. Well 87' N/A N/A N/A >25- TANK 9 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Greer Capacity 11250 Gal. j Surface Water >100' N/A N/A N/A Material Number of compartments Lot Line >5' N/A N/A N/A Plastic 2 NA Foundation >10' N/A N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Well waiver OSV191067 Pump on level at in. Pump off level at in. High water alarm at in. Tank Serial #: 1746 Tank only permit. Tank is Insulated. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D3034 Tank drainfield D3034 Installer Isaac's Excavating Drainfield Existlnq CO/MT MMA Inspector J. Mlllette / J. Williams BENCH MARK (Assumed elevation) 100 ft Inspection151 8/6/19 Location and description nd dates: 2 3`d 4th Bottom of siding. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Fa° Conditional Approval: Date ���P� ........ ®� •Q9th -M = �.....` . ...... ............ .. ..3..... esa.......a.a...............asn.caaana.. MICHAEL E. ANDERSON ���� % No, CE -4381 0 �� tP • �l� pFo.,,•.8130/190 •..°�4� Approved Date �� ���b �of4"��C'� inspection Repor;_yji-iz.aoc PROFILE AS-BUILT (NO SCALE) 96.1 90.9 96.9 99.9FCOMH SV2CO1250 GAL SEPTIC TANK 95.8 PERMIT # OSP191264 PID # 017-141-34 BIRCH TREE ESTATES, BLOCK 2 LOT 2 8/29/19MT12" INSULATION EAST 745TH AVENUE 4 N 99 43'44 " E 150 00 OF -A 49 TH* `y S 6 U SHANE A. HOLT/G LS -6914 ' o` O 4^ 4a a o �n'°fessions% Ls�� THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES- EASEMENTS OF RECORD, OTHER THAN THOSE APPEARING ON THE RECORD PLAT ARE NOT SHOWN HEREON ( UNLESS INDICATED) NOTE 2 FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS. ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE - AS -BUILT SURVEY V =30' NO CORNERS SET THIS DATE (I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT 2, BLOCK2,, BIRCH TREE ESTATES ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST OTHER THAN NOTED. DATED AT ANCHORAGE,ALASKA THIS 4 TH DAY OF JUNE , 2020 HOLT LAND SURVEYING 9309 GROVER DRIVE ANCHORAGE, AK 99507 345-5513 i MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP191264 Work Type: SepticTank Upgrade Tax Code Number: 01714134000 Site Legal Address: BIRCH TREE ESTATES BLK 2 LT 2 G:3037 Site Mailing Address: 5074 E 145TH AVE, Anchorage Owner: SCALLY MARTIN J & CHRISTINE A Design Engineer: FORGE ENGINEERING This permit is for the construction of: ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Depal-tYtl(11t Effective Date: 7/3/2019 Expiration Date: 7/2/2020 Lot Size in Sq Ft: 44982 Total Bedrooms: 4 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing (g/5 /19) Roves -a_v\,k 4�- o cum v Received By: Date: -S //(p Issued By: Date: 7 3 vality of Anchorage P.O. Box 196650 0 4700 Elmore Road Anchorage, Alaska 99519-6650 ® (907) 343-7904 © Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Department On -Site Water and Wastewater Section x x x x VARIANCE/WAIVER REVIEW x x x x Waiver#: OSV191067 COSA#: Permit#:OSP191264 PID#: 017-141-34 Legal Description: Birch Tree Estates Block 2 Lot 2 Engineer: Forge Engineering Applicant: Martin & Christine Scally Your request for a waiver of the required 100 feet horizontal separation from the septic tank to the private well has been approved. The approved separation distance is 87.0 feet. See engineer's waiver request for justifications. This waiver approval applies to the proposed septic tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. r r r r r r K ... r. r r r. r .... r .... r r r .. r r r r.■■. r r r r.■■ IN ... r r.■■ r r .... r r .. K r r r r. r.■ r. l Waiver is Granted: X Waiver is not Granted: Date: � iApproved by: 1�� l �o� (�ZZZV/ Name of Reviewer ■■ .. r r ...... r r r M r■■ r r r ..... r ... r r r r. r r r r.■■ ..... r K .... r .... r r ... r r r ... r. r ... 1 **** VARIAN C E/WAIVER REVIEW. **** MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWERM/ELL PERMIT APPLICATION Parcel I.D. 017-141-34 Property owner(s) Martin & Christine Scally Day phone 242-9454 Mailing address 3705 Arctic Boulevard, #280 Anchorage, AK 99516 Site address 5074 E. 145th Avenue Anchorage, AK Legal description (Sub'd., Block & Lot) Birch Tree Estates, Block 2, Lot 2 Legal description (Township, Range & Section) Lot Size 44,982 Sq. Ft. Number of Bedrooms F001 `i APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) ❑X Septic Tank ❑X Upgrade ® (w/wo ADU) Holding Tank ElRenewal ❑ Duplex (D) El Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDESA VARIANCE / WAIVER REQUEST FOR: II Sep -NC TG1614L (, ��1� Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. F, Qc"�J� (Signature of property owner or authorized agent) Permit/Rush Fees:'�'I C' Date of Payment: Receipt Number: Permit No. 5P 04261 Permit App_.:- : ,...,c Waiver Fees: � 11 i Date of Payment: Receipt Number: C ' Waiver No. 0 ) � � C.V i M, August 5, 2019 MOA Development Services Department On -Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Birch Tree Estates, Block 2, Lot 2 — 5074 E. 145t" Avenue Septic System Design Dear On -Site Services Engineer: The septic tank on the subject lot has failed and must be replaced. We are submitting this design and permit application for the construction andlacement of a new 1,250 -gallon septic tank. The- p attached site plan identifies the location of the home and the existing well and septic system along with the new tank, location. No conflicts exist between this proposed tank and any other well or septic system, whether on this lot or adjacent lots. Wells on this and adjacent lots are shown. The new tank will be constructed near the same location as the existing tank and 87' from the existing well on the lot. A well to septic tank waiver request is attached. The proposed septic tank will also be 100' from all adjacent wells and surface water and more than 5' from the existing absorption bed. Please refer to the attached plan sheet for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, a o"q-----, Michael E. Anderson, P.E. 49th MICHAEL iE��ANDERSON ��+ 4 NC CE -4381,•: Zy �sTt` 8/5/19 >••' {• s 1 August 5, 2019 MOA Development Services Department On -Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Birch Tree Estates, Block 2, Lot 2 — 5074 E. 145"' Avenue Well to Septic Tank Waiver Dear On -Site Services Engineer: The existing septic tank on Lot 2, Block 2, Birch Tree Estates Subdivision is located 85' from the existing well on the lot at its closest point. The septic tank and well were originally constructed in 1983 and have been in constant operation since that time. The septic tank is now more than 35 years old and is at the end of its useful life and must be replaced. The new septic tank will be placed close to the location of the existing tank because insufficient fall if available from the house to the tank to allow gravity flow. A waiver is therefore required to allow the septic tank to be placed in its proposed location less than 100' from the well. The proposed septic tank will be constructed out of high density polyethylene with an unlimited useful life and will be located down slope from the existing well. Septic effluent that might surface from the tank would flow away from the well. The surface grade is 5% to 10% away from the well. Surface effluent contamination of the well is virtually impossible from the septic tank. Underlying soils on the lot are silty sand with gravel based on test holes completed in the past. No log is available for the well on the lot, but the well on the adjacent Lot 3, Block 2 is 81' deep and the static water level has been measured at 48' below the surface. We are assuming the well was drilled through silty sand and gravel material the fill depth. We are confident based on the use of the plastic septic tank and the aforementioned characteristics of the lot surface along with the well construction that the reduction in the protective radius of the well to 87' will not impact the quality of water from the water system. ADEC POINT ANALYSIS Bottom of Absorption Bed to Highest Water Table — 44' 5.2 Points Soil Absorption Type —Sand w/silt 2.5 Points Permeability — Silt or Sandy Gravel 1.0 Points Water Table Gradient - +10% Horizontal Separation — 87' TOTAL POINTS CO� A 6.0 Points 2.5 Points 17.2 Almost sure to be free from any form of contamination from household sewage. Sincerely, (} Michael E. Anderson, P.E. OF ........... a amu. 49th ;A a MICHAEL E. ANDERSON 0. NO. CE -4-381 4e Z�- ��T��'� °°'°°8.05-19 °.°•'`�r�' BIRCH TREE ESTATES, BLOCK 2 LOT 2 CO# -,I EDGE OF NEIGHBORING ASPHALT PARKING AREA PLACE NEW 1,250 GALLO"EPTIC TANK w/20" MANWAY 10' I1�ROM FOUNDATION AND 5' FRbM DECK/STAIR SUPPORT. CONNECT TO EXISTING ABSORPTION BED. LOT 3 EXISTI NGWELL ENGINEE R�HG EAST 145th AVENUE CHAIN LINK FEN E LOT 2 t C MH / / 4-BDRM HOME 1 I I I I i I a EX DECC SEPT ABSORPTION BED LIGHT POLE MI&SION EXISTING TANK>E�t MOA CODE. I LOT 1 I I i / EXISTING WELL 15' CREEK MAINTENANCE fiASEMENT 10' T&E EASEMENT / LOT 12 I ( LOT 13 NOTE: I I NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE LEGEND PROPOSED SEPTIC SYSTEM CO - CLEANOUT ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS 2CO - DOUBLE CLEANOUT PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC FCO - FOUNDATION CLEAN( SYSTEMS. FS - FLOW SPLITTER VALVE MH - MANHOLE 0 50 100 MT - MONITORING TUBE FEET SV - SEPTIC VENT 1"=50' TH - TEST HOLE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE ! ~]NEW MAILING ADDRESS LEGAL DESCRIPTION LOCATION NO. OF BEDROOMS ~ Z Manufacture~ Materi~ No, of compartments Liq, capacity in gallons H~MEMADE; Inside length Width Liquid depth ~ ~urer ~~~~ ~~t~ in ~allons ~ ~ell Foundation ~earest lot line PfiflMIT ~0. " ~~~ ~li~ Length of each line Total length of lines Trench width Distance be~e~n lines _ , ~ ~ Top of tile to finish grade Material beneath tile Total effective absorption area Q ~ ' ~ inches Length Width Depth PERMIT NO. Type of Cr m ~ANCE TO: ~ell ~ foundation Nearest lot line ~ ~s_ ~? ,.~, Depth Driller Distance to lot line PERMITNO.~ ~ DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS SOIk T~ST ~ATI~G APPROVED~ ~ DATE LEGAL 72-013 (Rev. 3/: MUNICIPALITY OF ANCHORAGE Department "' Health and Environmental 'rotection ~';~ ~ ~ 825 ,. Street, Anchorage, AK. ~9501 * * * HANDWRITTEN PERMIT * * * ,.,~;, Z:b/~ Permit 9~ WELL AND~ON-SITE SEWER PERMIT ~ . Applicant: ~_~ ~. ~ ~ Mailing Address: ~C3S C, ~ oc t on: 7 -? S ze: Type of Soil ~sorption System Is: Trench: ~Drainfield: Seepage Bed: Holding Tank Maxim~ N~ber of Bedrooms: ~ Soil Ratiny(sq.ft/br) /~0 The Required Size of the Soil Absorpti%n. System Is: DEPTH C~ LENGTH GRAVEL DEPTH '<DC' WIDTH .~ · The length dimension is the l~ngth(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). · * REQUIRED SEPTIC(HOLDING) TANK SIZE = /6~-~d GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. · * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line 'is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31, 1 9 8 3 * . * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence ~s remodeled S igne~: /!/..,,~ ./,..~~~ App 1 ic a~' SWP/024 (1/81) to inClude more that 3 bedrooms. ssue /3-,x BO Mr. John Kenedy Department of Health F, Environmental Protection 825 "L" Street Anchorage, Alaska 99501 RECEI ED Subject: Report on Inspection of Absorption Trench Excavation on Lot 2, Block 2, Birch Tree Estate. Dear Mr. Kenedy: Please find attached with this letter the soils log of the trench excavation on Lot 2, Block 2, Birch Tree Estate. During my inspection on March 27, 1983 morning, water was observed seeping into the trench at a depth of 7 feet, the interface of sandy 9ravel and fine sandy silt layers. The seepage water appears to have resulted from seasonal perched water, however, it could not be ascertained at this time. In order to circumvent the problem of groundwater, we recommend that the presently approved absorption trench type design be changed to either a drainfield or a seepage bed type design with the bottom of the trench located at a depth of 3 feet. This would require a fill of about 12-inches over the drainfield or seepage bed area to obtain a minimum frost cover of 3 feet over the top of the 9ravel backfill around the distribution pipes. The absorption rate recommended is 150 square feet per bedroom which is the same as the value used in the currently approved design by MOA. Attached with this letter is Figure 1 which show a possible layout for the drainfield option. Both the alternative designs described above to the absorption trench system would require the presently in-place septic tank to be raised by about 18 inches so that the invert of the septic tank outlet will be placed at 30 inches below the groundsurface. This would allow a minimum of 6 inches of gravel backfill required to be placed below the distribution pipes which are to be installed in 3-foot deep trenches. If you have any questions on this report or our recommendations, please feel free to call. Thanking you, Very truly yours, Z .~C~ S U LTA N T/$, INC,. , SCS/rrna SUBJECT ,,'~.,~...~'?"~L/-~/ ~'~;¢e"'~IC~ ~~ SHEET NO. OF CALC BY ~ DATE ~1~'~ CHKD B' '~ DATE ~~~ ~OB NO. CONIULTANTB, INC ' ~ ~; .................................................................................................................... ~ .......... ~.. '~', ..... ..~ .... : ......... : ......... : .... .,;. .~.~ ...... -;..;.; ....... : ......... : .... ~;.. ~ ; : '. ....... : · . *; ............ .. · ~ .......................... ,. , · · .; ; . . o ,'. , ,., %'(: /. PERFORMED FOR: LEGAL DESCRIPTION: SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST .-~. ~'~'~ ~..L-y' DATE PERFORMED: [] PERCOLATION TEST 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 / ~0~( ~r~. WAS GROUND WATER ENCOUNTERED? . IF YES, AT WHAT DEPTH? eeeelee, Sharad C. Shreslha ~" CE-5724 ..~ SLOPE SITE PLAN FL_A-F S ~I~ L 0 P I E Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes/inch) COMMENTS PERFORMED BY: r u CERTIFIED BY: DATE: TEST RUN BETWEEN FT AND ~ FT June 6, 1977 Robert Garrett 1200 West Dimond Boulevard ~pace 1415 Anchorage, Alaska 99502 Subject: Permit Expiration Dear ~. Garrett: A permit issued by this department for well and/or on-site sewer installation on .Lot 2 Block 2 Bir_r~hTree Estates has expired since the i~~-~ear. In the event you still plan to install the well and/or on-site sewer system, a new permit ig required. The original soil test may be used to obtain a current permit. If tl~ well has been drilled, a well log should be sent to this department to document the installation date. If you have any questions regarding the above matter, please do not hesitate to contact this office immediately at 279-2511, extension 224 or 225. Sincerely, L~s N. Buchholz, Sanitarian LNB. lj h PERHIT NO. blI_INI~Z:IPRLIT'T" ;iIF I:It-IC;Hr~iI:IISE DEPARTMENT f HEALTH AND ENVIRONMENTAL OTECTION 2510 E. ,JDOR RD., ANCHORAGE, 276-222i £4ELL Rr4E:, CIr-J--S; 76228 ) APF'L I CANT LOCRT I ON LEGAL ROBERT GRRRETT L2 B2 BIRCH TREE EST 1200 W DIMOND SP ±415 LOT~CI~E~ 344-5095 44982 SQUARE FEET TYPE OF SOIL ABSORBTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS SOIL RATING <SQ FT/BR)= i50 THE REQ. LIIRE£ SIZE OF THE SOIL ABSORPTION SYST~ IS' E:.EF"'TH= i5 LENGTH= GRF~,'EL E:,EPTH= THE LENGTH DIMENSION IS THE LENGTH (I~.FE~T> OF THE TRENCH OR BRRINFIELD. THE DEPTH OF R TRENCH OR PIT IS THE DI~RN~ BETWEEN THE ~LRFHCE OF THE GROUND 8N~ THE BOTTO~ OF THE ffXC~STION ~x!N~EET). "['HERE IS NO S~T WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEP~ OF~'~xGF~VEL BETWEEN THE OUTFRL. L PIPE AND THE BOTTOM OF THE EXCAVATION (IN"-.[EET~.. ~:EC~LI I REL) SEPT I I2 TAN~ S I ZE= BSCKFILLING Off 8NY S~STEM WITHOUT FINSL ~NSPECTION 8ND 8PPROVSL B'¢ THI~ [:,EPRRTMENT WILL BE SUBJECT TO pROSECUTION. MINIMUM DISTSNCE BETWEEN 8 WELL 8N~ 8NY ON-SITE ~EWSGE iO0 FEET FOR 8 PRIVATE WELL OR 200 FEET FOR 8 PLIBLIC WELL. WELL LOGS ARE REQUIRED 8ND MUST BE RETURNED TO THE DEPARTMENT WITHIN 5:0 [:,AYS OF THE WELL COMPLETION. SF'ECIFICRTIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER I NSTSLLST I ON. F'E~'f4 I T %,'RL I D FOR Of-IE ~'ER~: FROf"I I SSLIE I CERTIFY THAT l' I AM FRMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS 8N[:, WELLS RS SET FUR~H BY THE MUNICIPALITY OF ANCHORAGE. · "~' I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. '-'.=:' I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY RE~UIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED/~'O INCLUDE MORE THAN Z< BEDROOMS. .// .F'PL~NT ROB~ . ANCHORAGE FAIRBANKS CONSULTANTS, INC. JUNEAU 249 I~AST 51ST AVgNUE · P.O. BOX 6087 ' ANCHORAGE. ALASKA 99503 -- T£L£PHONE: 907-279-0483 * TELEX 090-35419 May 20, 1976 R & M No. 656230 Mr. Robert Garrett 1200 W. Diamond Space 1415 Anchorage, Alaska RE: Test Hole and Soil Log Report for Sanitary System Lot 2 Block 2 Birch Tree Estates Dear Mr. Garrett: We are submitting herewith the test boring results and our comments regarding soil conditions encountered at the subject ~ite. This investigation was performed in accordance with your request of May 10, 1976 and those procedures outlined in a letter dated July 15, 1975, by Mr. Roll Strickland of the Municipality of Anchorage, Department of Environmental Quality. A single test hole was put down within the Lot 2 area for the purpose of defining general subsurface soil conditions for the proposed sanitary system. Excavation was accomplished with a tractor-mounted auger type drilling rig and the~test hole was extended to a total depth of 19.0 feet below ground surface. The final log prepared for the test hole has been included in Drawing A-01. Ground water was not encountered in the test hole. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M CONSULTANTS, INC. James W. Roone .~.~ Vice President JWR/PJ/pe TH1 ORGANICS (PT) SAND SILT (ML) SAND W/TRACE; GRAVEL (SP) 0.0~ 0.5' 2.0' TH ~RA~x SAND SILTY SAN~SAN~,. SILT (SM ML) 7.01 10.0' SAND W/SOME SILT TRACE GRAVEL (SP) SAND W/SOME SILT (SM) 19.0' T.D. No Water Table Log Represents Location of Test Hole Lot 2 Block 2 Birch Tree Estates DwN; VRZ CKD: p,~ DATE:. , ~-20-7~ sc~.E~, ~.,,=~, INC. Log of Test Hole Robert Garrett Anchorage, Alaska GRID: PRO4. NO. ,656230 DWG. NO. A-O1 APPLIr "NT FILLS OUT UPPER HA' ONLY /' //h Phone Address ~//./~/ .~ Zip Code Lending Institution /2'. ~ ~' Phone Realty Co. & Agent Phone Address /~/?/~ ~. Zip Code Street Locati~ / ~ Z;~ z: Type of Residence Single Family Multiple Family No, of Bedrooms ~ Other Water Supply ~ Individual ~ ~ A~ACH WELL LOG. A wall Icg is required for all wells drilled since June 1975. Community For wells drilled prior to that date, give well depth (attach Icg if available). ~ Public Utility Sewer Disposal ~ Individual Year Individual Installed: / ~ Public Utility When Connected to Public Utility: ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSlNG CAN BE INITIATED. Time Time Time Time Date Date Date Date ~-"~... ~,~/,.._ _~;~ Inspector Inspector Inspector Inspector Field Notes: J~UNICIPALII¥ ur r~ ........ DEPT. OF HEALTH 8, //T/~. C~ ~.NV[RONMCNTAL pROTECTION SE.P 6 RECEIVED I..~ ) APPROVED BEDROOMS OF APPROVAL I ) DISAPPFIOVED I I COND,TIONALAPP~OVAL' Soils Rating Date Sewer Installed Well To Absorption Area Well Log Received / --~"~ {~ (,~ ~ ~ ~ 3 Well to Tank Septic Tank Size /~"g~/ ~ CHEMICAL & Gl ~OGIC~iL L~iBOR~ITORIES ~ .4L.45K~, INC,~~ TELEPHONE (907) 562-2343 ANCHORAGE56331NDUSTRIALB Street ~,ENTER Drinking Water Analysis Report for Total Coliform Bacteria TO BE COMPLETED BY WATER SUPPLIER WATER SYS~vl: Water System Name I.D. NO. Phone No. Mailing Address City State Year Code SAMPLE TYPE: ~//Routine "1:::]"Check Sample (for routine sample with lab ref. no. ) [] Special Purpose [] Treated Water [] Untreated Water SAMPLE NO. 1 2 3 LOCATION TO BE COMPLETED BY LABORATORY ~,,~/r~alysis shows this Water SAMPLE to be: ,,~ Satisfactory [] Unsatisfactory [] Sample too long in transit; sample should not be ovbr 48 hours old at examination to indicate reliable results. Please send ,~. new sample. Date Received ~)' _~ / "' ~" '~ Time Received ./ ~'-~"J (.I~ Analytical Method: [] Fermentation Tube ~ Membrane Filter ,I Lab Ref. No. Result* Analyst *No. of colonies/100 ~[.jOr No. of Positive pprt ons 0~.1220 (b) Rav. 1978 BACTERIOLOGICAL WATER ANALYSIS RECORD READ INSTRUCTIONS BEFORE COLLECTING SAMPLE Data Collected Sourca a.m. Data Recalved TIma Recelve(I p,m, Lab, No. Presumptive 1Omi 1Omi 10mi 10mi 10mi ],.Omi 0.1mi 24 Hours 48 HOurs Conflrn~tory 24 Hours ,48 Hours EMB Broth ~4 hours: Multipla Tube Report: Membrane Filter: Direct Count Verification: L.TB Final Membrane Filter Result. s, ~ J Broth 48 hours: 1Omi Tubas Positive/Total 1Omi Portions Coll/orm/Z00ml BGB