HomeMy WebLinkAboutBIRCHWOOD ACRES LT 2 Municipality of Anchorage Page 1 of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISIO'N . P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: swgRo247 PIDNumber: 051 -231 -29 Name: MM&M Contracting Wastewater System: P.O. BOX 670495 Chugiak, AK ABSORPT Phone: I No. of Seclrooma: 688-1236, Thre9 r'l D~p Trench ~allow Tren LEGAL DESCRIPTION soi, LoC Bloc~: Su~ivmion: OeOffi m ~ige ~om from odgina gm,e: 2 N/A Birch, oDd Acres Township: I Range: ~ S~tion: F~oove original gra~e: WELL: ' ~ew ~ Upgrade ~a~ w~et~: ~ Ft Cl~fi~aon (P~vate, A.a,C): · Total D~: ~ To: To~'~aon Private 61 F~ 61 w~: Sullivan ~ater 7/22/9 25 ~ ~ SEPARATION DISTANCES ~.,,c ~ Holding Sudace w~te~ ~1~' ~lf~' F~ ~/* Lot ~I , Remarks: m~~10 ~UY,'~ /~,*U/~ BENCH [~suZa[~o~ placed ove~ east e~d o~ t~e~ch pe~ co~t~acto~. Inspections performed by: Dates: 1st 8/31/98 2nd R/~1/98 Depadment of HealtAand Human .e ,ewe ..rove. mew [] Upgrade ION FIELD ID Bed I'1 Mound I-1 Other Total Depth from original grade: Gravel depth beneath pipe ,(D Ft Gravel length: ~-~ ~. Number of lines: J Distance between lines: Date installed: 8/31'/9B . K ,- ID 8.T.E.P. Capecit~ in gallons: Number of Compartments: ~TION I High water alarm at: per/ormed by: MARK ~/_~ 72-013 (Rev. 9191) MOA 25 Permit No. SW0980247 Page 2 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: LT 2~ ]~rchwood Acres Subd~vi.~o. PID No.: 051 -231 -29 O SP2 " ,, C Clean/Out MT Monitor Tube 10' Otilit7 E~mt. compartment 1 Permit No. SW980247 Page 3 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: LT 2, Btrchwood Acres Subd~.v~.s~.o~ PID No.: 051-231 -29 $P2 C MT ELEVATION AS-BLT 1" = 10" Septic P,,ump, compartment 1 Clean Out Monitor Tube FROM : MMM CONTRRCTING PHONE NO. : 6881258 NOV. ooo ~o. SULLIVAN WATER WELLS ~.O. ~O~ 6T0~72, CHUGIAK, A~ASKA ~S87 · TELEPHONE 688-~T~9 ' ' 06 1B~ 11:22~M P1 'OWNER OF LAND 8,0RE HOLE DATA ,DEPTH ADDRESS ,,.. . TAX I,NDENTIF!CATION NUMBER la'31 ' 'Is Well located at approved pe~it location? ~'~ No Method of Drilling'. ~ta~: ~ cable tool C,~ing ~ype ~'7~.~Wa[I Thickness ~ ' q~erType: ~. , "' ' ' ........ . Cas/no 8~lckup Above Ground: ~' feet Static.Water' Level (from ground level')', _:, ~ 'foot Pumping level: ....... feet a~e~ ..... hrs. pumping gpm Recover Rate: .... ?~ gpm Well Intake Opening Type: .~ Open End ~ Open H01e' 0 Screened; Sisal ', feet Stopped. .feet ~ Pe~orafions Sta~ feet S{Opped .... feet: Grout Type: ~T~'~ ._Volume'.' Depth', from ~ feet, t° / feet Pump Intake Depth: feet', P~p Size hp Brand Name Well Disinfected Upon Completion? ~" ~ No Name es onsibilit of the 'property owner to submit a oopy of the well log to the proper authority. Munlclpalit ATTENTION: It is the r 13... ,Y. ...... .__.; .....-'-- ,,-.-~-~-,,, ,,~ Environmental Conservation. MatSu Borougl' of A~ohorage; Department ot Mealtl~ ii Human ~erv.oe~ a~u~u. ~=~.= ............ Department of Environmental Conservation, MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 · 2 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date Issued: Jul 17, 1998 Expiration Date: Jul 17, 1999 Permit Number: SW980247 Legal Description: BIRCHWOOD ACRES LT 2 Design Engineer: Anderson Engineering Owner Name: MM&M CONTRACTING Owner Address: P.O. BOX 670495 CHUGIAK, AK 99567-0495 Parcel ID: 051-231-29 Site Address: Lot Size: 23088 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Date: July 8, 1998 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Subject: Lot 2, Birchwood Acres Subdivision Septic System Design Impacts to Adjacent Properties Dear Onsite Services Engineer: We are hereby applying for a permit to construct a new well and septic system on Lot 2, Birchwood Acres Subdivision. The lot is currently vacant with no development to the east. The attached site plan and backup documentation identify the size and location of the new absorption trench to serve the home. It also shows the location of the proposed well and the 100' protective radius. Testhole No. 1 which was placed near the area of the proposed absorption trench consisted of silty to poorly graded sand which percolated at a rate of 3.3 minutes per inch.. Groundwater was noted during excavation at the 12.5' level and remained at that level during the monitoring period. We are therefore proposing to construct a 5' wide trench system with 4' effective depth. Total length will be 40' with the distribution piping at 4' below the existing ground surface. Total depth of the trench will be 8'. The surface of the lot slopes from north to south at varying rates with grades ranging from 2% to 5%. The slope in the area of the proposed absorption trench is fairly flat with a minor slope from east to west. The lot is relatively small, but sufficient area exists for the placement of the new and reserve site and the well radius. No conflicts exist between the septic system area and other wells or septic systems in the area. Lot 2, Birchwood Acres July 8, 1998 Page Two If the system is constructed as designed the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserved space, either surface or subsurface, on any lots located in the area. ,. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments no well or wit'hin septic 50' ~1 135 no well or~ septic area within 100' / Birchwood no well or septic area within 100' Loop '~ Rd. 33 ' AREA MAP SCALE 1" = 100' EN lS (10/78) BY CHKD. BY ' JOB NO. 40'I~ X 5' X 4' Eff. De' ,~,',~,'~, %,.',~' ,,~ z~' .... "~ .......... ""'~" ~"~ PLAN 488 I-E -/ LOT 2, DESIGN FACTORS: Three Bedroom Home Perc. Rate: 3 MinJlnch Application Rate: 1.2 GPOISF BIRCHWOOD ACRES SUBDIVISION SYSTEM REQUIREMENTS: $' Wide Trench System 1,000 Gallon Septic Tank 4' Drainfield Rock 3 Bedrooms X 1S0 GPD / 1.2 GPDISF = 37S SF of Absorption Area 37S SFIS LF (Width) X .$ (Red. Factor) = 40 LF Trench Length Therefore: Construct a $' Wide Absorption Trench System With One Lateral 40' In Length with 4' cf Drainfieid Rock Beneath the Lateral. Distribution Pipe in Trench Placed at 4.0' Below the Original Ground Surface. . 458i Slope Surface to' Drain Away - Natural Backfill NOTE: .TYPICAL WIDE TRENCH SECTION (NO SCALE) Grade Area Over Trench to Drain Away. Minimum 3' of Cover over Septic System. Minimum 4' Separation From Groundwater. Minimum 10' Separation From Lot Line. PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Aiasl~a 99502-0650 SOILS LOG -- PERCOLATION TEST MMM Contracting, Inc. Township, Range, Section: COMMENTS WAS GROUND WATER ENCOUNTERED? SLOPE IF YES. AT WHAT DEPTH? SITE PLAN 3~ Gro~ Net Def~n to Net Time Time Water Dr~ PERCOLATION RATE __ TEST RUN BETWEEN __ PERFORMEDBY:~ I ~~'"' L~""~.~IFYTHATTHIS3'EST ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDEUNES IN EFFECT ON THIS DATE. DATE:' "7/' ~'~ / ~' ~!~ WAS PERFORMED IN PERFORMED FOR: LEGAL DESCRIPTION: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 'L" Street, Anchorage, AlasKa 99502-0650 SOILS LOG -- PERCOLATION TEST MMM Contracting, Inc. Township, Range, Section: g ~/~ . SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? DEPTH? De,th to / Re,ding Drm Gro~ Net Dep~ to Net Time Time Wirer Drop COMMENTS /~' '~ Y"~' ~.~'V/'~// ~,/.,G2 ~ / / PERFORMED BY: ~ I~ ~y ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DAT[ DAT~ 72~ (Rev, 4/~) PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER THAT TH/IS TF~fiT WAS PERFORMED IN ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 2, BIRCHWOOD ACRES GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,000 gallon septic tank. It also includes the construction of a new 40' long by 5' wide by 4' effective depth absorption trench at the location shown on the site plan. The distribution piping must be placed 4' below the original ground surface. The total depth of the trench must not exceed 8'. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,000 gallon septic tank must be procured from an approved source and installed at the location shown. Lot 2, Birchwood Acres July 8, 1998 Page Three 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted watertight couplings (Caulder, Fernco, or equal). with Lot 2, Birchwood Acres July 8, 1998 Page Four 5. A permeable geotextile fabric (Typar, Mirafi or equal)must be installed between the final drain rock layer and the native soil layer. 6. All drain'rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: A minimum of two inspections are required by Municipal Ordinance. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or I~its and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. Development Services Department j Phone: 907-3435904 On -Site Water & Wastewater Section Fax. 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 051-231-29 Expiration Date: S--'Z'Cl rZ OZ Z, 1. GENERAL INFORMATION Complete legal description Birchwood Acres Lot 2 Location (site address) 18733 S. Birchwood Loop Rd, Chugiak, AK 99567 Current property owner(s) Mailing address Real estate agent Yvonne Marie Mason Day phone (907)350-6479 18733 S. Birchwood Loop Rd Wendy Bringhurst 2. TYPE OF DWELLING: ❑Q Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 Day phone (907)854-1236 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well Q Private Septic ❑E Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Dista Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. Date: COSA Fee $ 550 Waiver Fee $ Date of Payment ?A2_ 3/2 Z Date of Payment Receipt Number. Receipt Number COSA # 05G 22 )O5h Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering (MJ) Phone (907) 522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503 Engineer's Printed Name Benjamin Schiller, P.E. 6. DSD SIGNATURE i System #1 Approved for 3 System #2 Approved for Disapproved Conditional approval for bedrooms bedrooms Date 2/2/2022 of Ar .4,9 i `'�P-9 49TM •*r Benjarkrv5chiller C2 2 2292 ..�`���' ll`F�pROFESSIQ0 bedrooms, with the following stipulations: �lll((rrrrr 40 �Qp,�1TY OF'�,���� .� 40 0AI- do M VV TER ANDVVA m 94 mT PRGG� Q n ER A- �^� 1 G� Original Certificate Date: Z ^zi — ZZ The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other 4i6 COSA Checklist blue sheet e— tdily COSA Checklist Legal Description: Birchwood Acres Lot 2 If more than 1 septic system on lot: COSA Checklist # A. WELL DATA ®❑ Well log is filed with Onsite (or attached) Date drilled 7/22/1998 Total depth 65 ft Cased to 65 ft FE -1 Sanitary seal is functioning correctly 0 Wires are properly protected Casing height (above ground) 24 in. Date of flow test for COSA 10/12/21 Static water level at beginning of test 8.5 ft. Comments B. TANK DATA Age of tank(s) 23 years Tank type/material Septic/Steel Measured operating fluid level in septic tank. 49 RI Standpipes/foundation cleanout per record drawing .Date of pumping 1/27/22 Sanitary Pumpers Parcel ID: 051-231-29 of Structure served by this system Well production at time of test 4.3 gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Forge Engineering Date of Sample 1/31/22 . FT STATION ❑ Require aintenance completed Age of lift station ears Lift station material Comments: D. ABSORPTION FIELD DATA Shallow Trench Which system tested (date installed) 8/31/98 Adequacy test date 10/12/21 0 ALL standpipes present per record drawing Results O Pass For 3 bedrooms Total measured depth from grade 5.4* ft (max) Fluid depth prior to test 23 in Measured depth to pipe invert from grade 3.6* ft (min) Water added 726 gal ❑ N/A — pressurized field 33 ❑ Monitor tubes go to bottom of effective. If not, state New depth in Elapsed 1440 depth into effective z.s` p time min ❑ Code -required soil cover over field Final fluid depth 25 in ❑ System presoaked Absorption rate '450 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) date of test) Gallons introduced gallons If yes, enter date Comments/Deficiencies: •1.0' final grade difference measured between cleanout and monitoring tube. COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' Yes Community Sewer Manhole/Cleanout > 100' dQ Yes if No ft M Yes if No ft Neighboring Tank > 100' Yes if No ft Private Sewer/Septic Line > 25' ✓M Yes if No ft Absorption Field on Lot > 100' Yes if No ft Holding Tank > 100' 0✓ Yes if No ft Neighboring Absorption Fields > 100' Yes if No Animal Containment > 50' p Yes if No ft ✓0 Yes if No ft less than required) Building Foundation > 10° ✓ Yes if No Manure/Animal Excreta Storage > 100' If absorption field is under driveway comment below Community Sewer Main > 75' ✓� Yes if No ft 0✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' F71 Yes if No ft Surface Water > 100' U Yes if No ft Property Line > 5✓� Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' F✓ Yes if No ft Private Wells > 100' Q Yes if No ft Water main.>.10'.... Q Yes if No ft Commu.n.ity dells > 200' Q Yes if No ft Water Service Line > 10' Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10° ✓ Yes if No ft If absorption field is under driveway comment below Property Line:> 1.0' Yes if No ft Wells on Adjacent Lots: Water Main > 10'✓Q Yes if No ft Private Wells > 100' ' Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft Community Wells > 200' Yes if No ft Surface Water > 100'✓Q Yes if No ft F. ENGINEER'S COMMENTS System passed but is more than half full. Monitoring tube should have debris cleaned out for more accurate testing in the future. G. ENGINEER'S CERTIFICATION l certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet OF AC11 49 TM Benjani i5chiller p' CE /12592 �kkF, PROFESSI �la Q v m VOTf. SU+GDUIG SE (b:i:^,!(L;rVES,Ij Sr-L'Jt"Al r."✓ fii± CCIA rL i / EAST 14851 EAST 148.51 OF q !HW( sf SHANE A. HOLT �G �4P LS -6914 - O 4�a ....... ao %Q1 jessiona\ Loo SURVEY ORDERED BY: AS-BUILTSURVEY I" =30, :renrivCnnghmsf NO CORNERS SET THIS DATE JxcOer"'Aur"s I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT 2, BIRCHWOOD ACRES SUB. ( PLA TP - 643) THE INFORMATIon t{EREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICkLLY TO SHOW ANY ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES. THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EASEMENTS OF REC0RD'0R ANY LEGAL ENTITY, OTHER THAN THOSE APPEARING ON THE RECORD PLAT EXIST OTHER THAN NOTED. ARE NOT SHOWN HEREON( UNLESS INDICATED) DATED AT ANCHORAGE,ALASKA THIS 15 Tl -I DAY OF NOTE: FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE NOVEMBER , 2021 PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS. ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE. THE SUR VfYDATA ON THlS DRAVJINGIS PREPARED FOR THE OWNER OF RECORD ONLY HOLT LAND SURVEYING 9309 GROVER DRIVE ANYCOPYINB, OR UT/(/ZING THE DA TA HEREONTS PROHIRITfD (/ADERCOPYRIGt m/ ANCHORAGE,AK 99507 15293• F8219-27 345-5513 DEVELOPMENT SERVICES DEPARTMENT On -Site Water and Wastewater Section www.muni.org/onsite IL 0 907-343-7904 ,.^ Fax: 343-7997 S"fic Tank Advisory Certificate of On -Site Systems Approval #OSC 221056 Subdivision: Birchwood Acres Lot 2 Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for this property i's 23 years old. Typical replacement costs range from $9,000 to $12,000 This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 20 -year-old steel tank MAY look like. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 1. GENERAL INFORMATION Complete legal description Lot 2, Birchwood Acres Location (site address or directions) Mile 1.8 Birchwood Loop Road Property owner MMSM Mailing address 9.O. Contracting Day phone 688-1 236 Box 670495 Chugiak, AK 99567 Lending agency Mailing address Agent Address Day phone Day phone Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: NOTE: Three (3) Individual well Community well Public water XXX If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: XXX If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025(Rev, I/91) Front MOA#21 STATEMENT OF INSPECTION BY ENGINEER ~ As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the, Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's signature Date 11/16/98 DHHS SIGNATURE Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments Date//- The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91) Back MOA #21 Legal Description: Lot 2, A. WELL DATA Well type Private Log present (Y/N) Y Total depth 61 ' Sanitary seal (Y/N) Municipality of Anchorage i ~I~1[~~ DEPARTMENT OF HEALTH & HUMAN SERVICES R E ¢ E Environmental Services Division 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-47~0V 2 0 1998 Health Authority Approval Checklist MUNICIPALITY Of ANCHORA(~, ENVIRONMENTAL SERVICES DIVISION Birchwood Acres Parcel I.D.:, 051 -231 -29 If A, B, or C, attach ADEC letter. ADEC water system number Date of test Static water level 2 5 ' Well production 5 WATER SAMPLE RESULTS: Coliform 0 Date of sample: I I / 1 2 / 9 8 B. SEPTIC/HOLDING TANK DATA Date installed 8 / 31 / 9 8 Tank size Foundation cleanout (Y/N) ¥ Date of Pumping New Pumper C. ABSORPTION FIELD DATA Date installed 8 / 31 / 9 8 Soil rating Length 3 9.5 ' Width 5 ' Effective absorption area 3 9 5 SF Date of adequacy test New Const. Fluid depth in absorption field before test (in.); Fluid depth (ins) Minutes later:. Peroxide treatment (past 12 months) (Y/N) 72-026 (Rev. 3/96)* Date completed 7 / 2 2 / 9 8 Cased to 6 ! ' Casing height (above ground) 2 ' ¥ Wires properly protected (Y/N) Y FROM WELL LOG AT INSPECTION 7/22/98 g.p.m. g.p.m. Nitrate .1 7 mg/L Other bacteria Collected by: MEA I, 0 0 0 Number of Compartments .. 2 Cleanouts (Y/N) Depression (Y/N) N High water alarm (Y/N) N Construction Y (g.p.d./ft~ or fta/bdrm) I. 2 Gravel thickness below pipe Monitoring Tube present (Y/N) ¥ Results (Pass/Fail) P a s s Immediately after Absorption rate = System type 5 ' Wide 4 ' Total depth 8 ' Depression over field (Y/N) __ For 3 ' gal. water added (in.): g.p.d. Trench N bedrooms If yes, give date D. LiFT STATION ~ None on Lot Date .installed "i' Size in gallons Manhole/Access (Y/N) "Pump on" level at* "Pump off" level at* High water alarm level at* *Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field on lot Public sewer main N/A >100' >100' On adjacent lots > 1 0 0 ' On adjacent lots > 1 0 0 ' Public sewer manhole/cleanout Sewer/septic service line > 2 5 ' Lift station N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation > 5 ' Property line ;> ,%, Absorption field. Water main/service line > 1 0 ' Surface water/drainage > 1 0 0 ' >5' Wells on adjacent lots > 1 0 0 ' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: Property line > 1 0 ' Building foundation > 1 0 ' Water main/service line Surface water > 1 0 0 ' Driveway, parking/vehicle storage area > ,5 ' >10' Curtain drain None on Lct Wells on adjacent lots F. ENGINEER'S CERTIFICATION I certify that l have determined thru field inspections and review of Municipal rec~JXl~'~p.t,~e.f~l~-,~ rems are in confo~ance with MOA H~ guidelines in effect on ~is dam. Signature * Engineer's Name Michael R_ Date ' ' 11/16/98 HAA Fee $. ~/~/- ~ Date of Payment /'//'~//~ ~ Receipt Number /~ ~;I~'~"'~':~Y~)/) Waiver Fee $ Date of Payment Receipt Number 72-026 (Rev. 3/96)*