HomeMy WebLinkAboutCENTRAL BIRCHWOOD LT 168B
Municipality of Anchorage Page
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: ~-~[J ~3~"~ ~ ~' [ _,C"~ PID Number'. ~;)¢'-~ ! ! '"~'~-'"~
~~ ¢. ~ ~~¢ ~. ~~ Wastewater System: ~ New ~Upgrade
~:~ ABSORPTION FIELD
Phone: INs of~ooms: ~eepTrench ~ShallowTrench ~Bed ~Mound ~Other
LEGAL DESCRI PTI O N so,, Rating: ~- 4~PD/Sq. Ft. Total Depth from original grade:
Subdivision: Depth to pipe bottom from original g~e: Gravel depth beneath pip~
Ft.
Township: I Range: I Section: Fill added above original grade: / Gravel length:
WELL: Q New ~ Upgrade Gravel width: C/Ft. Num~nes: I Distance between lines:
Ft.
ification(Private, A,~,C): - Total Depth: Cased To: Total absorption area: Pipe material: ~[
Driller: ~ Date Drilled: Static Water LevehFt. ~~ ~. Dateinstalled:~/~/~
Yield: GPM ~ Pump Setat: Ft. ICasing Height AbOve GrOund:Ft. TANK
SEPARATION DISTANCES ~eptic ~¢~ Holding ~ S.T.E.P.
To Septic Absorption Lift Holding Public/Private Manufacturer: Capacityt i~lon~:
From Tank Field Station Tank S .... Lines ~ ~~
i~ ~1~ ~ ~ Material: Number of Compartments:
Well ~ ~
Surface
Water I~'~ ~¢~. ~ ~ ~ LIFT STATION
LineL°t, ~/~~ ~
] I~ I Size in gallons: Manufacturer:
Foundation ~l ~ ~ ~ ~ "Pump on" level at: ~:'1[ High water alarm at:
CurtainDrain ~ ~[~ ~[~ ~, ~ ~[ ~ pu~ Electrical. Inspections performed by:
Remarks: BENCH MARK
Location and Description:
Assumed Elevation:
ENGINEER'S SEAL
Inspections performed by: 170~Ea~l. Riv.rLo~R~$,~ lSI~I~'~ ~o;
,.
Department of Heard Hum~ Services apprcval//
~eviewed and approved by: Bate: '~'~-~~~~
72-013 (Rev. 9/91) MOA 25
Permit'No. SW950210 Page 2 of 2
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
iter Disposal System and/or Well Inspection Report
Legal Description.CENTRAL LOT 168:B PID No.: 0511 5347
W-ELIg 100' WELL RADIUS
t ' DIVmTER V~
FINAL GR~ 'C01 ~.8' X C~2 MT2
ENGI~~AL
& 91.5' NO ~ATER FOUND . , .. ~ ~ ~.,?
72-013 A (Rev. 9/91) MOA 25
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW930210
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:PORTER JACK V & LORETTA E
OWNER ADDRESS:19961 BIRCHWOOD LOOP RD
EAGLE RIVER, ALASKA 99567
PAGE 1 OF 1
DATE ISSUED: 7/12/93
EXPIRATION DATE: 7/12/94
PARCEL ID:05115347
LEGAL DESCRIPTION: CENTRAL BIRCHWOOD LT 168B
LOT SIZE: 44160 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT:
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4329 OR 343-4681 AFTER BUSINESS HOURS
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS
DATE:
ROBERT SHAFER, P.E.
ROGER SHAFER, P.E.
CIVIL ENGINEERS
(907) 694-2979
FAX 694-1211
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& ELOW TEST
SITE PLANS
ROAD DESIGN
SOIL TEST
PERCOLATION
TEST
4unicipality of Anchorage
)EPARTMENT OF HEALTH AND HUMAN SERVICES
325 L Street
~nchorage, AK 99519-6650
~FE~NCE: Central Birchwood Subdivision, Lot 168B
request you issue a permit to upgrade the septic system
~erving the four bedroom house on the referenced property.
~wner reports existing septic system is in a state of
~ailure.
test hole was excavated and a percolation test performed.
~he approximate location of the test hole is located on the
attached site plan. The monitoring tube within the test hole
~as been checked and found to be dry.
Ie do not anticipate any adverse effects on neighboring
)roperties by the installation of the proposed septic system.
[f you have any questions, or require additional information
for your review, please contact us.
A. Shafer, P.E.
s/nsu/lsu
STRUCTURAL &
MECHANICAL
INSPECTIONS
ON SITE
WASTE WATER
DISPOSAL SYSTEM
DESIGN
17034 NORTH EAGLE RIVER LOOP ' SUITE 204 · EAGLE RIVER, ALASKA 99577
1"'= 40'
SCALE
JUPGRADE I
BIRCHWOOD OP
__~0
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Central Birchwood Subdivision, Lot 168B
GENERAL:
1.
®
The scope of this project includes the installation of a
leachfield trench to serve the four bedroom residence
located on the referenced property. The existing septic
tank is to be excavated to verify integrity. If of poor
integrity, the tank is to be abandoned and a new tank
installed.
Construction shall be in accordance with the approved
site plan and design drawings; Municipal permit with any
special provisions or conditions; and all applicable
State and Municipal Wast·water Disposal Regulations.
The contractor shall be responsible for obtaining any
necessary underground utility locates.
Unless specifically agreed otherwise, the property owner
shall be responsible for final grading areas subsequently
depressed from soil settling. On all leachfield mound
systems, the property owner shall be responsible for
ensuring a satisfactory vegetation growth over the
mounded area.
Contractors installing wast·water disposal systems must
be certified by the Municipal Health Department for
system installations. Owners installing their own
systems must also receive prior approval from the
Municipal Health Department.
SEPTIC TANK INSTB?.?.qTION:
A septic tank is to be constructed by a certified septic
tank manufacturer. Construction shall include two 4"
cleanouts for pumping access.
The septic tank shall be sufficiently bedded to prevent
settling or shifting of the tank.
Ail standpipes on the septic tank shall extend a minimum
of 12 inches above final grade.
Page Two
Central Birchwood Subdivision, Lot 168B
June 20, 1993
Septic tanks installed with less than 4 ft. of cover
shall be insulated.
A foundation cleanout shall be installed one to four feet
from the building foundation. In the line between the
tank and the leachfield there shall be two adjacent
cleanouts (unless an effluent pumping system exists
within the septic tank). These cleanouts shall be
located on undisturbed soil not more than 10 ft. from the
tank. The first cleanout, in line, shall be to clean
toward the leachfield. The second cleanout shall be to
clean toward the septic tank.
Final grading over the septic tank shall be such that a
positive slope exists away from the septic tank.
ABSORPTION TRENCH/DRAINFIELD INST~?~.qTION:
Excavate the proposed trench to the dimensions shown on
the design. The bottom of the excavation shall be within
2 inches of level. If the sidewalls of the excavation
become smeared, they must be raked or scratched (ruffed-
up) before gravel (sewer rock) placement·
Once the gravel is installed, the distribution pipe is to
be installed level with the perforations faced downward.
Gravel is then to be placed over the distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
A silt barrier must be installed between the final gravel
layer and the native soil backfill. Ensure the silt
barrier covers the entire gravel surface before placing
backfill.
Monitor tubes shall be of four (4) inch diameter and
installed approximately in the locations shown on the
design. The portion of the monitoring tube extending
through the gravel shall be perforated from the bottom of
the trench to the invert of the distribution pipe. This
is equivalent to the effective depth of the gravel as
noted on the design.
Backfill over the final gravel layer must not be less
than twenty-four (24) inches. Insulation must be
installed when the backfill depth is less than thirty-six
(36) inches. The finish grade over the trench must be
mounded to prevent the formation of a depression after
settling.
Page Three
Central Birchwood Subdivision, Lot 168B
June 20, 1993
MINIMUM NATERIAL SPECIFICATIONS:
Any septic tank proposed for installation must be
constructed by a Municipally approved septic tank
manufacturer.
0
The following pipe materials are approved for use in
septic system installations in the Municipality of
Anchorage:
Type of Pipe
Perforated Solid
Cast Iron
ASTM D3034 (PVC)
ASTM F810 (HDPE)
ASTM D2662 (ABS)
Yes Yes
Yes Yes
Yes No
Yes Yes
Use of a type of pipe other than listed above must be
approved by the inspecting engineer.
e
Insulation shall be at least 2" thick extruded direct
burial polystyrene (Dow Chemical Company Styrofoam HI or
equal).
Septic tank inlets and outlets shall be fitted with
watertight couplings (Caulder, Fernco, or equal).
A permeable nontoxic silt barrier (Typar 3401, Mirafi
140N, or equal) must be installed between the final
leachfield gravel layer and the native soil backfill.
®
Ail leachfield gravel (sewer rock) shall be 0.5"-2.5"
screened gravel with less than 3% passing the ~200 sieve.
®
When sand is being used as a filter material, it's
gradation specifications must conform to AMC 15.65.060D.
Page Four
Central Birchwood Subdivision, Lot 168B
June 20, 1993
INSPECTIONS:
Typically there will be a minimum of three (3) inspections
required during the installation of the wastewater disposal
system. These inspections will occur as follows:
The first inspection must be conducted after the
excavation of ditches, pits, trenches, or beds and
before the installation of any gravel. A septic
tank may be set in place, but may not be backfilled
before this inspection.
e
The second inspection must be conducted after the
placement of the silt barrier, gravel, distribution
lines, standpipes, cleanouts, and insulation, but
before the placement of any other backfill.
e
The final inspection is to occur upon final grading
of the property.
Often there will be more than these 3 inspections required.
Especially with the installation of multiple trenches, sand
filters, pressurized distribution systems, etc. Thus, the
inspecting engineer is to be contacted at least 24 hours prior
to the start of construction. If necessary, a pre-
construction meeting will take place on-site.
PERFORMED FOR:
LEGAL DESCRIPTION:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
DEPTH
(FEET)
t
3
4
!
?
8
10
13
14
17
~ ' ~,H.
19
20
SLOPE SITE PLAN
WAS GROUND WATER hO
ENCOUNTERED?
S
IF YES, AT WHAT ~ g
DEPTH? p
E
Depth to Water Alter,~,,.,..~,
Monitoring? ]...) I ~J/ Date:
Gross Net Depth to Net
Reading Date Time Time Water Drop
:~o ~ o 9 Y~ " yz
PERCO,AT,ON RATE qO (minutes/inch) PERC HOLE DIAMETER
4-i~z TESTRON.~TWEEN g.$ .TAND 7,
COMMENTS f),~g
I I
CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MuNl~u ~ulDEL ON THIS DATEDATE. DATEDI :
72 008 (Rev 4/85)
, DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 00501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME [.PHONE
[] UPGRADE
MAILING ADDRESS
LEGAL DESCRIPTION ~~
LOCATION~ NO. OF BEDROOMS
J Well ~ Absorption area Dwelling PERMIT NO
~ DISTANCE TO: /~ O '~ /~ ~ /W ~ ~ ~ ~
~ Z Manufacturer ~~~ Mat~al~-~ ~ N°' of compartments ,~
Liq. cqpacity [n gallons Inside length Width Liquid depth
/ Z- ~/ ~ If HOMEMADE:
~ DIS~E~ . Well Dwe]ling PERMIT NO.
~ -- ~ M~ac~r~/ ~ Material ' Liquid capacity in gallons
~ Well Foundation Nearest lot line PERMIT NO~~~
DISTANCE TO: / ~ ~ ' ~ ~
~ -- ~ No. of lines Length of each line lotsI length of lines Trench width Distance between lines
~ ~ / 3 ~ inches
~ Top of tile to finish grade ~'1 Material beneath tile ~ ~ II inches Total effective absorption areaz O.~ t
Length Width Depth PERMIT NO.
~ T~~ Crib diameter Crib depth Total effective absorption area
m /DI~A~'E T~: Well Building foundation Nearest lot line
~ ~ Class ~/~ Depth Driller Distance to lot line PERMIT NO.
~ DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s)
OTHER
PIPE MATERIALS
3034
/ , . ,
INSTALLER ~
REMARKS ~ ~
13 (Rev. 3/78)
tV1-W DRILLING, Inc.
P.O. Box 10-378 · 10300 Old Seward Highway
(907) 349-8535
ANCHORAGE, ALASKA 99511
DRILLING LOG
' JACK %7. ~)l~i~_dR Use of Well
Well Owner ~,~
Location (address of: Township, .Range, Section, if known; or distance main road Lot 168 B Centre~ 3~?c!r~x~d ~ubdivision
Size of casing. 6" Depth of Hole 76 feet Cased to 75.5 feet
Static water level 64 ft. (lfl~ (below) land surface. Finish of well (check one)
Screen ( ); Perforated ( ).
~e
Describe screen or perforation
Well pumping test at. 5 gallons per of drawdown from static level.
June 25, lq83
Date of completion
open end (
>tx );
(minute) for 1 hours with ]O!TL
WELL LOG
Depth Ln feet from
ground surface Give details of formations penetrated, size of material, color and hardness
0 .TO. 2 Cas~ stickup
2 .TO 3
3 .TO. 10
10 .TO. 22
22 .TO. 38
38 TO. 41
51 .TO. 55
55 TO. 7I)
70 TO. 75
TO
.TO.
.TO.
__.TO
.TO
.TO.
Organic
Silty ~ravel
$~ty ~ravet
Sandy gravel
Silty gravel
~ gravel
Sm~dy ~mterbearing gravel
· ~os. 814 & ~;7r
3- CONTRACTOR
PERMIT NO.
~,4,.{.,---4../ //..~,.-'
t-1 L! I'-.I 1- C: I t :-, L l- T 'T' II--i F R I'-.I C: H,, F~.' R G E ~ --
DEPRRTMENT
AN[:, EN.IR_NMENTHLn - F'R. OTECTION .~c~]}~_~'~' ~" \~
I-IF
HEALTH
:---:25 '"L'" STREE¥., ANCHORAGE, AK. 99501
264-4720
I-.-IELL RI"-.I[) ,_-"1"-.I--"_=~ I TE CEI...IEF.: F'EF~:t-1 I T
( 8-<05F'~0 )
APPLICANT
LOCATION
LEGAL
JRCK VAN PORTER
L±68B CENTRAL BIRCHWOOD
90±± SHRUN CIRCLE 99502 243-0449
LOT SIZE 999999 SQUARE FEET
TYPE OF SOtL FIBSORPTION SYSTEM IS: TRENCH
MAXIMUM N'L~ME~ER OF BE[:,F,:OOMS = _--.-:
SOIL RATING (SQ FT/BR)= 264
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEbl IS:
[)EF'TH= 12 L E r-.~ I-~'T H = ~_-i ~.-E~ Ci I(: !:!"..-' E L [:,EF'TH=
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD.
THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE
AND THE BOTTOM OF THE EXCAVATION (IN FEET;).
E:E6!LI I E:E[:. SEF'T I C: TAr-IF=:: c I ZE= :1. ~Z~rZl~Zl mSRLLC,~-IS
PERMIT HFFLI_.HNT HAS THE RESPONSIBILITY TO iNFORM THIS DEF'RRTMENT DLIRING THE
INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE
NUMBER OF RESIDENCES THAT THE WELL WILL SERVE
Tb-lC~ < 2 ) I I'-~'_--;F'EC:T I C,l'-.tS RE:E E:ELT!LI I F-:E[:,
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPRO'v'RL BY ;'HIS
DEPARTMENT WiLL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCE BETWEEN
"100 FEET FOR A F'RI'v'ATE WELL OR 150 TO 2E~E~ FEET FROM A PUBLIC WELL [:,EF'ENDING
UPON THE TYPE OF PUBLIC WELL
MINIMUM DISTANCE FROM A PF.:IVRTE WELL TO FI PRI'v'RTE SEWER LINE IS 25 FEET AND
TO A COMMUNITY SEWER LINE IS 75 FEET.
WELL LOGS ARE REQUIRE[:, AND MUST 8E RETUF'.NE[:, TO THE DEPARTMENT WITHIN 3:0 DAYS
OF THE WELL COMPLETION.
OTHER REQUIREMENTS MAY RPPL"r'. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS RF.'.E
fl',,"AILflBLE TO INSURE PROPER INSTALLATION.
I CERTIFY THAT
±: I AM FAMILIAR WITH THE REL-]UIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH B'-r' THE MUNICIPALIT"r' OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN RCCORDANE:E WITH THE CODES.
-<: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MFP'r' REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN _-< E:E[:'ROOMS.
SIGNED:
RF'PLICRNT JACK VAN PORTER
SSI_lED BY_ ....
V4. E~
PERI. I E ~
OEPF~ THEN T OF HEF~L TH RNO ENV [RONHEN I'll_ PRO FEC, r t ON
RPPL[CRNT .rRcK YRN PORTER ~g~ ~-HF~JN C[R¢I.E ~3-502
LOCR T £ '3N
LEOP]L L~r~8 CENYRRL ~I~.CHWOO& LOT
TYPE OF '$OH. RSSORPTION ~YSTEM I~: TRENCH
~P Tt~= i2 LENGTH= 6g GR8%.'EL OEPT~=
THE L~OTH OIr~ENSI~ IS THE L~ (IN F~T) I~ THE TRE~ OR
~E O~TH OF R TR~2H OR PIT I~ TH~ O[STRNCE BE~
~ROtJNO R~ rile 80TT~ OF ~ E~CRVRT[~ <~N FEET).
T~E I~ ~ ~T WIO~ FOR tREnCHES.
~JD THE 8OTTOM OF ~E ~VRT[ON ~N
PERMIT RP~IC~T HRS THE ~5PONiES[LEKY FO [~ORN ~[5 ~RRKI~NT D~[~ THE
TtUO ( 2 ) I NSPEO ? X ON5 ARE RK,2U}I RED ~--
DEPAAKHENK W KLL 8~ 5US~ECF TO PROSECU F
~IINIP~UH OI~l'Rt~'E 8EFMEEN
· ~ FEET F~
UPON THE rYP~ OF PUBLIC
t~[H[t~UH OI~ TRNCE
TO R COHHUN [ ~
OF T~ b~L ~HPLE F KON.
~VRfLROI.E TO INSURE PRt3P~ [NSF~LRYfON. ,/
FORD( 8Y THE H~ICIPALITV OF
OR rE__ . . =. ___
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
SOILS LOG
PERCOLATION
TEST
PERFORMEb FOR:
LEGAL DESCRIPTION:
Triad Engineering
Test Hole 2 Birchwood Loop Road
DATE PERFORMED:
3-8-82
tl Il
1 II
I t
I
I tl
II
t
1
2
3
4
5
6
7
8
9
lO
11
12
13
14
15
16
17
18
19
2o
COMMENTS
PEAT, PT
SILTY GRAVELLY SAND, SM
Frozen~to 2.5'
Tan SILTY SANDY
moist
GRAVEL', GM
SLOPE
SITE PLAN
SE~ A1TA(:HE[ SITE PLf N
FI AI'E I
WAS GROUND WATER S
ENCOUNTERED? N0 L
O
IF YES, AT WHAT
MoiSt to wet DEPTH?
Larger gravel at
15.0'
TOTAL DEPTH OF
BORING 20.0'
, PEI~CO LATION RATE
No free water observed
TEST RUN BETWEEN
Gross Net Depth to Net
Reading Date Time Time Water Drop
SEE ATTA(:HED PLATE 4
[minutes/inch)
6.0 FT
PERFORMED BY: Cherie McCracken CERTIFIED BY:
J.M. Lambe
DATE:
72.008 (6/79) 3
J ~
SOIL AND MATERIALS
ENGINEERING
AND TESTING
John M. Lambe, P.E.
4101 Arctic Boulevard · Suite 205 * Anchorage, Alaska 99503
907-276-4113
March 17, 1982
Triad Engineering
6937 Old Seward Highway
Anchorage, AK 99502
Attention: Dave Grenier
Subject:
Soils Investigation Lots 168A & 168B in Eklutna, Alaska
Dear Sir,
This letter presents the results of the soils investigation
that we performed at your request on Lots 168A and 168B in the
Bi rchwood Loop Road area. This work was requested to be per-
formed to the minimum standards of the Department of Health and
Environmental Protection (D.H.E.P.). These standards include the
drilling of a soils boring to a depth of 20 feet and the visual
classification of the soil strata encountered by a field tech-
nician. No laboratory analyses are requested. In soils which
are visually classified to include more than 6% silt, {soil finer
than the #200 screen size), a ~percolation test is required to be
performed in the area most likely to be developed for the ab-
sorption system. Our procedure for performing the percol.ation
test is to drill an additional boring adjacent to the soils log
to the depth intended for percolation testing., Coarse gravel is
placed in the bottom of the boring. Four inch slotted and per-
forated PVC pipe is placed within the percolation test boring and
the annular space between the boring and the pipe is backfilled
with washed gravel. The percolation boring is filled with water
and allowed to saturate overnight. Percolation testing is per-
formed the following day according to the standards presented in
the E.P.A. publication "On Site Waste Water Treatment and Dis-
posal Systems," Page 41, Table 3-8.
All soils are visually classified in the field according to
the Unified Soils Classification System presented on Plate 5 and
the textural classsification system presented on Plate 6. Per-
forated 1-1/2 inch nominal standpipe was placed in the deep
borings to allow for observation of free water level after drill-
ing. In soils with a significant silt fraction, substantial
time, often several days, is required to allow the free water
level to stabilize. While no free water was observed in these
observation standpipes the days when the percolation testing was
performed, it should be noted that the free water level may
fluctuate seasonally and annually in response to seasonal runoff
or heavy rainfall.
The results of the field investigation and percolation test-
ing are presented on the attached plates. The soils logs are
presented on the standard D.H.E.P. form attached as Plates. 2 and
3. The locations of the borings are presented on Plate 1. The
results of the percolation testing are presented on our form,
P1 ate 4.
We were requested to perform this investigation to the
minimum standards required by the Department of Health and En-
vironmental Protection. It should be noted that, in accordance
with these standards, the classifications of the soils are visual
and performed by a soils technician. These classifications are
subject to change as they have not been verified by laboratory
analyses. This work was performed for the the sole purpose of
preliminary evaluation by the Department of Health and Environ-
mental Protection of the suitability of the lots for on site
sewer system development. Any extrapolation of this data for
other purposes is not within the intent of the investigation or
r. equested services. We trust the foregoing is sufficient to your
~mmediate needs and is comprehensive within its limited scope.
If questions arise or if we can be of any further service, please
feel free to call.
Very truly yours,
//John M. La~e, P.E.
Civil Engineer 4254-E
_ I Birchwood Loop Road
, /
t H 1 ' Test Hole 2
a /168-A 168-B/ :
.... ,/ / ,
~ I
I
'
I , I
i
~ I
Scale 1" = 100' Notes: 1. Test holes not located by survey methods.
2. Base drawing and contours from preliminary
plat provided by lriad Engineering.
,J L SITE PLAN PLATE
AMBE AND ASSOCIATES Triad Engineering
Soils Iaboratory and Geotechnical En§ineerin§ Birchwood Loop 1
Jobno. 87-341.02 Appr. dMk .Date 3/17/82 Eklutna, ^laska
f'~'4UNICIPALITY OF ANCHORAGE f~
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L. Street° Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
r"l SOILS LOG
[-I PERCOLATION
TEST
PERFORMEb' FOR: Trtad I~n_atneeri nq
LEGAL DEECRIPTION: Test Hole !
DATE PERFORMED:. 3/8/82
Birchwood Loop Road Lot 168A
PEAT, PT.
4
5
6
7
8
9
10
11-
13-
14-
17
18
19
20
SILTY GRAVELLY SAND, SM, TRACE
ORGANICS
Frozen to 2.5'
Tan SILTY GRAVELLY SAND, SM
moist
Few cobbles
SLOPE SITE PLAN
S~F ,TT~.HIFD !rTE PI'AN
FLAI E 1
WAS GROUND WATER
ENCOUNTERED? NO
P
IF YES. AT WHAT E
DEPTH?
Read;ng Data Gross Nat Depth 1o Net
Time Time Water Drop
SE' ATTACHED PLATE 4
TOTAL DEPTH OF
BORING 20.0' PERCOLATIONRATE ~4 (m;nut~linch)
No free water observed -
~l~/~ TEST RUN "ETWEEN ~-~ FT AND ~_n FT
COMMENTS
PERFORMED BY: Cherie McCracken CERTIFIED BY: O.H. Lambe
72-001 (6~9)
DATE:
2
PERFORMED FOR:,
LEGAl. DESCRIPTION:
(~'"~,'IUNICIPALITY OF ANCHORAGE t'~
· DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 g Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
Triad Engineering
DATE PERFORMED:
Test Hole 2 Birchwood Loop Road
SOILS LOG
PERCOLATION
TEST
3-8-82
1
2
5
6
7.
8
g
10
11,
12-
t3-
14-
· l
18'
CO['.IM ENTS
PEAT, PT
SILTY GRAVELLY SAND, SM
Frozenqto 2.5'
Tan SILTY SANI
GRAVEL
SLOPE SITE PLAN
SCl A'TA(HEI S TE PU q
A1 E I
MoiSt to wet
Larger gravel at
15.0'
ENCOUNTERED? ' HO
IF YES, ATWHAT ,, /
DEPTH?
TOTAL DEPTH OF
BORING 20.0' PE
No free water observe~c°tATl°N RATE
TEST RUN BETWEEN
SEE ATTAI NED PLATE 4
I
[m;nute$/inch)
5,5 FT AND 6.0 FT
PERFORMED BY:
Cherie HcCrack~n
CERTIFIED BY: JoH. Lambe
DATE:
~ 0 0o ev~
Triad Engineering
Soils La~ratory and Geotechnical En~tneerinD 8trch~ood Loop 4
Jobno.. 82-347.02 Appr. ~ML Da/e~ Eklutna Alaska
•
• PGt QG
• Municipality of Anchorage
On-Site Water and Wastewater Program ei 1
(907) 343-7904 SA [*.V
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
Parcel I.D. 051-153-47 Expiration Date: SP' —2&P.--/
1. GENERAL INFORMATION
Complete legal description CENTRAL BIRCHWOOD LOT 168B
Location (site address) 19961 BIRCHWOOD LOOP ROAD, CHUGIAK,AK 99567
Current Property owner(s) RICHARD &CRISTINA JENSEN Day phone
Mailing address 19961 BIRCHWOOD LOOP ROAD, CHUGIAK,AK 99567
Real Estate Agent Day phone _
2. TYPE OF DWELLING:
• Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well ® Individual
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community ❑
Public Water System ❑ Public Sewer ❑
WaiverNariance request for: Distance:
Received by: %2ee2 c "% ee/ L Date: ..V.,,/g//88
COSA to be released to the engineer,unless othe s r quested by the engineer.
COSA Fee $ 5-061 Waiver Fee $
Date of Payment -J -Ql Date of Payment
Receipt Number 6QQ9VO Receipt Number
COSA# 666/3/0100 Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm ARCTERRA CONSULTING,INC. Phone 868-3791
Address 20441 PTARMIGAN BLVD.,EAGLE RIVER,AK 99577
Engineer's Printed Name KENNETH M. DUFFUS Date 2/20/2018
Engineer's Comments:This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition
of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface
conditions that may not be observed from the surface,changes inland use,local soil characteristics,groundwater levels that may fluctuate
during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are
subject to these various and dynamic characteristics and are outside the control of the
evaluator of the well and septic system. Therefore,
ArcTerra can not give any estimate of how long a
system will function satisfactory for current or future
occupants or can ArcTerra guarantee that no unseen ,•• OF A
encroachments,deficiencies or discrepancies exist. 'cks
L/,‘) y
r * 4iTI-i .'
6. DSD SIGNATURE - AMY
KENN • M. 7 y System #1 Approved for bedrooms. � rra 7tt. 1 j
System #2 Approved for bedrooms. 1 o 2
&it)' SSto-�V
Disapproved. `•�`-��
Conditional approval for bedrooms, with the following stipulations/.
vai_to _PI6D c1-6 Q t- s 0,..:0**4 0L-0
'� SITE
ON- m,:
WATER AND
d
WASTEWATER oz
PROGRA �,
0441
`Ge<'gO
Original Certificate Date: 2' ^1
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other---moo
cosA blue sheet 10-1O-12.doc
If more than 1 septic system is on the lot:
COSA Checklist# of_
Structure served by this system _
Certificate of On-Site Systems Approval Checklist
Legal Description: CENTRAL BIRCHWOOD LOT 168B Parcel ID: 051.153.47
A. WELL DATA
Well type PRVT If A, B, or C provide PWSID#_ Well Log (Y/N) Y
Date completed 6/25/1983 Sanitary seal (Y/N)Y Wires properly protected (Y/N) Y
Total depth 76 ft. Cased to 75.5 ft. Casing height(above ground) 24 in.
FROM WELL LOG AT INSPECTION
Date of test 6-25-1983 2/15/2018
Static water level 64 ft. 67 ft.
Well production 5 g.p.m. 6.2 g.p.m.
WATER SAMPLE RESULTS:
Coliform A _1 colonies/100 mL Nitrate 5,79 mg/L
Arsenic: A ? ug/L Date of sample: 2/15/2018 Collected by: ARCTERRA
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material SEPTIC I STEEL Date installed 8.1983
Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout(Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N
Date of pumping1129H �/J 9/i& Pumper,JR< jet 1-a,Y ptA44 S
C. ABSORPTION FIELD DATA
Date installed 8/13/1983 Soil rating (g.p.d./ft2 or ft2/bdrm) 264 System type DEEP TRENCH
Length 88 ft. Width 3 ft. Gravel below pipe 8 ft.
Total depth 13*ft. (see comments) Eff. absorption area 1408 ft2 Monitoring tube Y Depression over field N
Date of adequacy test 1/30/2014 Results(Pass/Fail) PASS For 4 bedrooms
Fluid depth in absorption field before test 11.5 in. (Below Invert) Water added 790 gal. New depth 2 in. (Above Invert)
Elapsed Time: 1365 min. Final fluid depth 13.5 in. (Below Invert) Absorption rate >= 600 g.p.d.
Any rejuvenation treatment(past 12 mo.) (Y/N &type) N If yes, give date
D. LIFT STATION
Date installed Size in gallons Manhole/Access(Y/N)
"Pump on" level at_in. "Pump off' level at_in. High water alarm level at in.
Datum Cycles tested Meets alarm &circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot 100'+ On adjacent lots 100'+
Absorption field on lot 100'+ On adjacent lots 100'+
Public sewer main 75'+ Public sewer manhole/cleanout 100'+
Sewer/septic service line 25'+ Holding tank 100'+
Animal containment areas 50'+ Manure/animal excrete storage areas 100'+
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main 10'+ Water service line 10'+ Surface water 100'+
Wells on adjacent lots 100'+
ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main 10'+
Water Service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+
Curtain drain 50'+(NONE KNOWN) Wells on adjacent lots 100'+
F. COMMENTS
*System is 13'from existing grade based on recent measurements. 5'of the 8'effective depth is measurable from the sump invert with
5'of cover. The 1993 system is saturated. Subsequently,the 1983 system was pre-soaked per code then tested. The septic tank is 35
years of age and the 1983 field is operating in the upper reaches of the effective depth. It is unknown how long the system will continue
to operate satisfactorily for the users,based on these observations.
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in conformance
with MOA COSA guidelines in effect on this date. i'� ff,O 4 j4 '
Engineer's Printed Name KENNETH M.DUFFUS /
Date 2/20/2018 / * A 9 LI-1 . w: *
��w�i17/
COSA canary sheet_2-6-15.doc /
KENNE M.1 /' IS /
4 \ .
7 18\ „„.
'PE SS IOh '
in r0
14) In
BIRCHWOOD LOOP ROAD _
N89'44'05"W 148.84' M
(N89'49'53"W 148.32' R)
20' T&E ESMT J
PP
— —0/H— —0/H— r] 0 O FT=—O7 - =0/I4 —e/H! --0/I— 0/H— —0/H-e
ELEC
N-ELEC PAVED
METER D/W
in
a
rn
®WELL
` CEDRE....
RY0 PAVED
ift
38.9' .">'
44.0. 11111 D/W
LA
,z}- "= �` COVERED
14.0' ENTRY
EXISTING 49.o. 13.1' CC
0 N N SE HOU1..-x----x---
Zv 52.6' oi
i.
a - DECK • 79.0' IN c)
w LU x N
m uu •nnuuonn ll
LOT o rn �� LOT
168-A `V x° a) 167
rcoN
Q � Ior
mN "00
N I O
-Cr) SEPTIC• 12.0' i Z
O VENT
Oo (typ) • W I
z $• N I
II
1
x
LLI • i
N w
LOT .,
16.0• 168-B
8.0' ;
v
SHED
• :
•
‘k_— N89'41'16"W 148.74' r —�
(N89'49'13"W 148.60' R)
ANCHORAGE RECORDING DISTRICT,ALASKA
• =FND ALUMINUM MONUMENT
ASBUILT OF:
CENTRAL BIRCHWOOD SUBDIVISION O• =FND 5/8"REBAR
LOT 168-B PLAT 82-129 _`"\
SURVEY CERTIFICATE:I,John L.Schuller,Have conducted a g OF' .A�N` , . LA U411,-
..... ,4
physical survey of this property as shown on this drawing and that the / `� . .`Qs�1 4 N.° r„ f,
improvements situated hereon are within the property lines and no oir<S„!:.' 1 '�'k ,v,w� 1F'G,�t,,�,
enchroachments exist other than noted.Under no circumstance should / :' 49TH i\ %.Y 1w N ,0
any information on this drawing be used for construction of fences, % 0,
structures,improvements,or for establishing boundary lines. / / U
EXCLUSION NOTES:It is the owners responsibility to determine ,o .
�� tn. 9," 1:,, n
e (C.-
HN L. SCHULLER: °/ 1 ' .')
the existence of any easements,covenants,or restrictions which ,,p. �,�
do not appear on the recorded subdivision plat. 1'�'. LS-10408 . ..' .�._.,,.
WORK ORDER NUMBER: DATE: SCAM (-MA 1�e '' , g�j� 1831 Anchorage,Talkeetna Street
FEB 23, 2018 1"=40' 1�ap •;$• �a / Alaska 99508
18—010 KN BY:aIEOED en mno M soCK/PAOE: \�°fessionot 'P (907) 227-1455 office
JLS NW1256 180111 \\VIieglibill'" (907) 274-4992 fax
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
I . `f�,'�!' 907-343-7904
On-Site Water and Wastewater Section `� �� Fax: 343-7997
www.muni.org/onsite
OSC181060
Nitrate Advisory'
Certificate of On-Site Systems Approval # OSC181060
Subdivision: Central Birchwood, Block: , Lot: 168B
A water sample revealed a nitrate concentration of 5.19 milligrams per liter (mg/L).
The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. Please see the attached "Nitrate Fact Sheet" for important
information regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On-Site
Systems Approval.
Mailing Address: P.0. Box 196650 * Anchorage,Alaska 99519-6650 *www.muni.org
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Se[vices Section
P,O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
Parcel I.D. #
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
GENERAL INFORMATION
Complete legal description
g
Location (site address or directions)
19961 Birc/,~ood Loop Road
Chuqiak, AK
Property owner Jack Po,'~ex
Mailing address 19961 B~.c/~oood Loop Road
Day phone 688-2602
Chugiak, AK 99567
Lending agency
Mailing address
Day phone
Agent Mike Ga~st/MARSTON PROPERTIES
Address
Day phone 248-2804
Unless otherwise requested, HAA will be h.eld for pickup.
NUMBER OF BEDROOMS:
TYPE OF WATER SUPPLY:
Individual well
XY, X
Community well
Public water
NOTE:
TYPE OF WASTEWATER DISPOSAL:
Individual on-site Y, XX
Holding tank
Community on-site
Public sewer
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system. .
NOTE:
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. 1/91) Front MOA #21
Se
STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply'
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verifythat based on the information obtained from
the Municipality of Anchorage files and from my investigation. and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm
Address
Engineer's signature
DHHS SIGNATURE
~"' Approved for
~ Phone (~;~'Z/
S & $ ENGINEERING ~
bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
Additional Comments
The Municipality of AnChorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the p,'ofessional engineer's work..
72-025 (Rev. 1/91) Back MOA #21
Municipality of Anchorage
Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: ~.~o-~ 1 ~ ~ ~ ~'C~-~..t~ ~ ¢c~-,e~arcel I.D.
A. Well Data
Well type ~,,j ~..~
Log present~N) ~
Total depth -7 L.,'
Sanitary seal ~/N) ~
Date of test
Static water level
If A, B, or C, attach ADEC letter. ADEC water system number ~.
Date completed ~, ~ ~5'~- E,~ Driller t'~ - X~
Cased to -7 S~, ~"' Casing height 1 7-'('Ir'
Well flow
Pump level1
Wires properly protected (~N) ~
FROM WELL LOG AT INSPECTION
.._Z.-L'- .---- ¢.,~
~ o g.p.m. ~r' g.p.m. ,~ ~
; On adjacent lots
; On adjacent lots
Public sewer manhole/cleanout
Petroleum tank
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot
Absorption field on lot \
Public sewer main
Sewer service line ~-~'~'
tltt
WATER SAMPLE RESULTS:
Coliform
Date of sample:
Nitrate
Collected by:
Other bacteria
B. SEPTIC/HOLDING TANK DATA
Date installed ~:;)-~ ~'5 Tank size '~ '?-..~-'-,:~ Compartments
Cleanouts ~/N) ~ Foundation cleanout (~/N) ~ Oepression,(Y~;I.~
High water alarm ('~ J Alarm tested (Y/N) h'~[
Date of pumping ~ _~c_,[~ Pumper "~-~ ~..~..s.Spoo
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot \ ~?'7-~ ~ On adjacent lots
To property line \ ~ ~ '~ Absorption field
Surface water/drainage ~ ~ o
Foundation
Water main/service line
72-026 (3~3)* Front CONTINUED ON BACK PAGE
C. LIFT STATION
Manufacturer
Manhole/Access (Y/N) .----- ..---
~s tested
Date installed
Size in gallons
Vent (Y/N)
"Pump on" level at
High water alarm level
Meets MOA electrical codes (Y/N) ..~
SEPARATION~E FROM LIFT STATION TO:
Well on lot On adjacent lots
D. ABSORPTION FIELD DATA ~ l"~¢'-¢-- (-~{5 ~
Surface water
------- After test
If yes, give date
Date installed '7-~/~'~ ~-~ Soil rating (GPD/FF) ~, ~5"- System type
Length ,/~ ~ / Total depth /
Width ~ J Gravel thickness ~', ~ ~
Total absorption area ! ~ 5'~'~ ~ Cleanout present {~;/N) V Depression over field (Y~)
Date of adequacy test /~J/~ -~ ~l~J~ Results (pass/fail) ~ for Bedrooms
Water level in absorption field before test
Peroxide treatment (past 12 months) ~
1
Well on lot /
To building foundation
On adjacent lots
Surface water
Curtain drain
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
On adjacent lots /~ o / ~- Property line
~' ~ ~ To existing or abandoned system on lot
'~ ~ ! ~- Cutbank "¢'~/r- Water main/service line
! o ~ ~ ¥ Driveway, parking/vehicle storage area
E. ENGINEER'S CERTIFICATION
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect o~n. J¢e.. ,,, ~¢~te... ~,, of this inspection.
Signature $ & S ENGINEERI
17034 Eagle River I.~d No. 204
Engineer's Namea¢_~ R!,,e_.,
Date
HAA Fee $ ~:) - ~--~
Date of Payment
Receipt Number
Waiver Fee $
Date of Payment
Receipt Number
72-026 (3/93)* Back
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
GENERAL INFORMATION
Complete legal description
Location (site address or directions)
,/
Property owner
Mailing address
Lending agency
Mailing address
Agent
Ad dress
./¢¢ .¢ /
Day phone
Day phone
Day phone
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
NOTE:
Individual well
Community well
Public water
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
NOTE:
Individual on-site
Holding tank
Community on-site
Public sewer
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. 1/91) Front MOA #21
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm Phone
David R. Daytolt P.E.
Add ress 20210 Dona{ar-~t.
Chugiak,
Alaska
99567
Engineer's signature Date
DHHS SIGNATURE
~ Approved for J bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
Additional Comments
By: / ' Date ~ ,
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-025 (Rev. 1/91) Back MOA #21
( Municipality of Anchorage
Department of Health & Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: L~T//~'~ (_~o'.r/z,~._ g~C_z:~o Parcel I.D.
A. WELL DATA
Well type f2£~ t,,/tw-'~
Log present (Y/N)
Total depth
Sanitary seal (Y/N)
If A, B, or C, attach ADEC letter. ADEC water system number
Date completed ~,'/2~//~F'-5 Driller /~4:/
7 (-~ ' Cased to -/'~-~ ~5'~- ' Casing height A~?
Wires properly protected (Y/N) 'Y/
Date of test
Static water level
Well flow
Pump level
FROM WELL LOG AT INSPECTION
'"" -'~:~5:~' g.p.m. '~' --
~ g.p.m. ~
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot
Absorption field on lot
Public sewer main
Sewer service line
; On adjacent lots
; On adjacent lots
Public sewer manhole/cleanout
Petroleum tank
WATER SAMPLE RESULTS:
Coliform ~
Date of sample: ////Z-~'/'~'
Nitrate
Collected by:
bacteria
B. SEPTIC/HOLDING TANK DATA
Date installed ¢//~/~_-3
Cleanouts (Y/N) ~
High water alarm (Y/N)
Tank size /~ 5'~~Compartments ~__
Foundation cleanout (Y/N) /~Y,/ Depression (Y/N)
Alarm teSted (Y/N)
Date of pumping
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot
To property line
On adjacent lots I oc:~ ~ Foundation ~"0
Absorption field 2- ~ Water main/service line ~/'~
Surface water/drainage
72-026 (Rev. 7/91) Front CONTINUED ON BACK PAGE
C. LIFT STATION
Date installed
Size in gallons
Manufacturer
Manhole/Access (Y/N)
Vent (Y/N)
"Pump on" level at
"Pump off" level at
High water alarm level
Cycles tested
Meets MOA electrical codes (Y/N)
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot
On adjacent lots
Surface water
D. ABSORPTION FIELD DATA
Date installed 9//~)/
Length ~'~ '
Width
Total absorption area
Depression over field (Y/N)
Results (pass/fail)
Peroxide treatment (past 12 months) (Y/N)
Soil rating Z ~ ~ Z~£ System type
Gravel thickness .-~ / Total depth
Cleanouts present (Y/N) ~/
Date of adequacy test I/~/~,
for
~ If yes, give date
bedrooms
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot I ~) On adjacent lots ~ ~ -r- Property line
To building foundation ~ To existing or abandoned system on lot
On adjacent lots ;;~"P- Cutbank '~/'/~ Water main/service line
Surface water ? ~ ~ Driveway, parking/vehicle storage area ~c:>
Curtain drain /~J//~
E. ENGINEER'S CERTIFICATION
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signature
Engineer's Name
Date
David R. Dayton P.E.
~,-~i~ I:~nalar St.
Chugiak, Alaska ~567
HAA Fee $
Date of Payment
Receipt Number
72-026 (Rev. 3/91) Back MOA 21
Waiver Fee: $
Date of Payment
Receipt Number