On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: _~14/ 95'0087 PIDNumber: 01~'1~'~3¥
Wastewater System: [] New [] Upgrade
Address:
Phone:
¢/o KZZ -,~-9 e"e" [No.
of
Bedrooms:
LEGAL DESCRIPTION
Lot: Block: Subdivision:
7 Chatet Terrac~
Township: [ Range: I Section:
WELL: [] New [] Upgrade
Classification (Private, A,B,C):
Driller:
Yield:
Total Depth:
ICased To:
Pt.
Date Drilled:
I
Pump Set at: I casing Height Above Ground:
GPM Ft. Ft.
SEPARATION DISTANCES
TO Absorption
Field
From
Well-
Surface
Water
Lot
Line
Foundation
Curtain
Drain
Remarks: t-,em
Deep Trench
Inspections performed by:
ABSORPTION FIELD
Soil Rating:
l, 0 GPD/Sq. Ft.
Depth to pipe bottom from original grade:
~.~' Ft.
Fill added above original grade:
O, ~ Ft.
iGravel width:
[] Shallow Trench [] Bed [] Mound [] Other
Total Depth from original grade:
Gravel depth beneath pipe
Gravel length:~
SQ. Ft.
Total absorption area:
Installar:
/8r~ FO leo..
Ft.
Ft.
Number of lines: Distance between lines:
J -- Ft.
Pipe material:
TANK
[] Septic [] Holding 61'S.T.E.P.
Manufacturer:
Material:
,~c £heel
Capacity in gallons:
Number of Cg.~partments:
LIFT STATION
Size in gallons: I Manufacturer:
"Pump on"~.~,level at: "Pump ¢,;,::.1 at: qHigh ;~e ~alarm at:
Pump Make & Model Electrical Inspections ~Hormed by:
'1~ k ~.0. ~. ~/ec
BENCH MARK
Location and Description:
O~ ~ ~"~ ' tO'( 'AV~" Assumed Elevation:
IOO. 0
~ ~t~ ~ n~ ENGINEER'S SEAL
Dates: 1st
2nd 6'/
Department of Health and Human Services approval
Reviewed and approved by: ~ ~' '"//)~'"~ Date: ~- 2~-
72-013 (Rev. 9/91) MOA 25
i ' PERMIT NO: SW950087
O: 01516334
I/ CLASS "A"
WELL
PAGE 2 OF 2
,' SWING TIES:
LOT 7 """~ : " .......
, FROM CORA COR B
TERRACECHALET I' TO:
'" ..... I FDN. C.C. "C" 2' 38'
.2 i;i"G" ~ S.T.C.C. "D" 28' 52'
-- I::'ZIRTIN~ i;I ~,, S.T.M.H. "E" 36' 57.5'
BB~'I~'~I'~ I!I TR. M.T. "F" 56' 78.5'
~j~ ,' ;I TR. u.m. "G" 58' 58.5'
NEW 39' LONG SOIL ABS TRENCH / ~ ....
WITH 6.4 SEWER GVL. BELOW PIPE ~ --
ROUGH GRADE OVER TRENCH 106.8'
.................................. B0 LONG SO L TRENCH W TH
:::f :::::::::::::::: =====================================================
~ ~ 03.4' ELEVATION 07.0' ~ 03.4'
LOT 7, CHALET TERRACE
SEPTIC SYSTEM UPGRADE
AS-BUILT INSPECTION REPORT
T.H. #1 M.T.
WATER @
85.4'
PROFILE VIEW
NOT TO SCALE
FLATTOP TECHNICAL SERVICES
14530 ECHO STREET
ANCHORAGE, ALASKA 99516
SCALE: AS-SHOWN
DRAWN BY TFM
JUNE, 1995
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
PAGE 1 OF 1
0N-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW950087
DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES
OWNER NAME:JANZEN EDWARD A
OWNER ADDRESS:7510 CHALET CT
ANCHORAGE, AK
DATE ISSUED: 5/24/95
EXPIRATION DATE: 5/24/96
PARCEL ID:01516334
LEGAL DESCRIPTION:
CHALET TERRACE LT
7
LOT SIZE: 14280 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT:
3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY: ,~~ ~
DATE: ~--/2- F/~--
DEPT. OF ENVIRONMENTAL CONSERVATION
TONY KNOWLES, GOVERNOR
ANCHORAGE/WESTERN DISTRICT OFFICE
800 E. DIMOND BLVD., SUITE 3-470
ANCHORAGE, ALASKA 99515
(907) 349-7755
May 22, 1995
Mr. Theodore F. Moore, P.E.
Flattop Technical Services
14530 Echo St.
Anchorage, AK 99516
RE:
Lot 7Chalet Terrace Subdivision. Horizontal Separation Distance Waiver Request
Between a Class "A" Well (Chalet Terrace PWSlD no. 211106) and Proposed
Replacement Septic System. ADEC project no. 9521-WV-130-040.
Dear Mr. Moore:
This letter is in reference to the materials received in this office May 10, 1995, requesting
a waiver from the minimum separation distance between a proposed replacement septic
system and the above referenced class "A" well. The Department has completed its
review of the submitted materials which included a cover letter with justification for
requested waiver, engineered plans of the septic system upgrade, and a well log. Based
upon this review it appears that a waiver may be granted in accordance with State
Drinking Water Regulations (18 AAC 80.030) subject to the following comments:
The proposed system is not expected to pose a greater contamination
source than the existing undocumented system. There are currently
several systems within the required 200 foot protective radius of the well
and analysis of nitrate levels while detectable have been steady.
o
Reconfirm the percolation soil rate during excavation of the on-site
wastewater disposal system. Trench designs require soils with a
percolation rate not less than 1 minute/inch.
Construction and installation activities must be monitored by a
professional engineer (P.E.).
Thank you for your cooperation with this Department, if there any additional questions
regarding the above please do not hesitate to call.
Sincerely,
Michael Lu, E.I.T.
Environmental Engineer
ML/pt
CIVIL & ENVIRONMENTAL ENGINEERING * ENERGY CONSERVATION & ANALYS~S
THEODORE F. MOORE, P.E. 14530 ECHO ST.
PH: (907) 345-1355 May 10, 1995 ANCHORAGE, AIJ~KA 99516
M.O.A. DHHS
P.O. Box 19-6650
Anchorage, AK 99519
Dear Sirs:
The purpose of this letter is to provide the required design narrative in support of our application for a
permit to upgrade the wastewater disposal facilities on Lot 7, Chalet Terrace S/D, located at 7510 Chalet
Court. The existing system, while still functional, includes an undocumented upgrade for which we
were unable to establish the required vertical separation from groundwater. Therefore, we propose to
abandon the existing system in its entirety and install a new STEP tank and soil absorption trench. A soil
log, perc test results, a site plan, design drawings and specifications are enclosed for your review. We
are also enclosing a copy of our application which we are concurrently submitting to D.E.C. for a
separation distance waiver from the Class "A" well which serves this subdivision.
The proposed system will be constructed in the vicinity of test hole # 1. As can be seen from the soil
log, the native material between 2' and 23' below ground level is a somewhat silty sandy gravel with a
measured perc rate of slightly faster than lminute per inch. Using a slightly conservative soil application
rate of 1.0 gpd/sq, ft., this 3 bedroom residence requires a total absorption area of (3 x 150)/1.0 = 450
square feet. The proposed 38 foot long soil absorption trench with 6.0 feet of sewer gravel beneath the
horizontal distribution pipe has a total absorption area of 456 square feet.
Despite the fact that the percolation rate is slightly less than 1 minute per inch, we feel that a soil
absorption trench is the best system for this lot. There is a very limited amount of space available and the
lot slopes at approximately 15% in this area, making a bed type system with an underlying sand filter
difficult to construct. Furthermore, it has been our experience that bed type systems in Alaska tend to fail
significantly more rapidly than trench type systems. We do not feel there is significant potential for
groundwater contamination because of the high sand and moderate silt content in the soil. The seasonal
high groundwater level, as determined by our monitoring during this year's breakup, is over 10 feet below
the bottom of the proposed trench. We are enclosing a copy of the lab results from a sieve analysis of a
sample of the material removed from the perc test hole. This shows that the sand and gravel fractions are
almost equal, which should provide excellent filtration of the septic tank effluent.
The proposed project will have no significant impact on present or future water supply and wastewater
disposal systems serving adjacent properties, nor will it have any significant impact on reserved space-
surface and subsurface, or on drainage.
Please give me a call at 345-1355 if you have any questions on this submittal.
Sincerely,
Ted Moore, P.E.
/ / ~ \
/ / T9 \ \ \
/ / \ \\ \
/ / \ ~ \
/ ~ / LOT 8
/ ~ \
/ \
'\
\
\ HOUSE
\
\
\
\
\SEPTIC
SYSTEM
o 'o..
SEPTIC
SYSTEM
HOUSE
CLASS "A"
WELL
LOT 6
LOT 7
/
/
SEPTIC TANK
EXISTING
~ ~ ~ L~I~ ~INSTAU
1250 GAL STEP TANK --
_ ---
UNDOCUMENTED
/ SEEPAGE PIT
1985
AECS
/_ .... ....
TEST HOLE ..-.-' ...-
/
LOT 1, CARR S/D / ~ ~'
O O
/
L__PRIVATE
/
/
/
/
/
I
I
I
\
\
\
\
HOUSE
\
\
WELL
POWER
POLE
/
/
/
/
//I
/ 1
/NEW 38' LONG
TRENCH
WITH 6' GRAVEL
\
\
\
/
/
/
/
/
/
LOT 7, CHALET TERRACE
WELL AND SEPTIC SYSTEM
SITE PLAN
FLATTOP TECHNICAL SERVICES I INCH = 50 FEET
14530 ECHO STREET DRAWN BY TFM
ANCHORAGE, ALASKA 99516 APRIL, 1995
NOTE: THIS IS NOT A SURVEYED PLAT.
ALL LOCATIONS SHOWN ARE APPROXIMATE.
HOUSE
NEW 38' LONG SOIL ABSORPTION TRENCH
WITH 6.5' GRAVEL (6.0' BELOW DIST. PIPE INV.)
I ~ INSTALL
× FDN. C.O.
ASTM D-3034
NEW 1250 GAL, ~
"STEP" TANK "A"~
1.25" DIA. SCHED 40 PVC
(NON-PERFORATED)
"A"
1,25" DIA SCHED 40 PVC
W. 3/16" DIA, HOLES SPACED 2.0' O.C.
PLAN VIEW
SCALE: 1" = 10'- 0"
M,T--
4" DIA. MONITOR TUBE
(PERFORATE PORTION
THRU SEWER GRAVEL)
RIGINAL GROUND
UNCLASSIFIED BACKFILL
(MOUND 12" ABOVE ORIG. GND.)
~___1.25" DIA SCHED. 40 PVC DIST. PIPE
(WITH 3/16" DIA. HOLES SPACED 2' O,C.)
1/2" - 2 1/2"
SEWER GRAVEL
BOTTOM OF
EXCAVATION
SECTION "A - A"
SCALE: 1" = 5' - 0"
LOT 7, CHALET TERRACE
SEPTIC SYSTEM UPGRADE
PLAN AND CROSS-SECTION
FLATTOP TECHNICAL SERVICES
14530 ECHO STREET
ANCHORAGE, AK, 99516
SCALE: AS SHOWN
DRAWN BY: TFM
DATE: MAY, 1995
Flattop Techn~al Services
14530 Echo Street, Anchorage, AK99516
Phone (907) 345-1355
Lot 7, Chalet Terrace
7510 Chalet Court
Wastewater disposal system installation
Specifications
1.0 General:
1.1 The scope of the project consists of abandoning an existing 1000 gallon septic tank and two
seepage pits, and installing a new 1250 gallon STEP tank which pumps effluent up into a new 38' long
soil absorption trench containing a total of 6.5 feet sewer gravel.
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
All construction procedures and material specifications shall conform with Municipal and State
requirements. All separation distances shall be in conformance with Municipal requirements, unless
specifically waived.
1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any
buried utilities.
1.4 The contractor shall provide adequate cover material and rough grading over all system
components to ensure that proper drainage is achieved after settlement and that there are no residual
depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas.
1.5 Unless specifically agreed otherwise, the homeowner shall arrange separately for finish grading
after the soil is compacted, as well as placement of any necessary topsoil and reseeding of areas disturbed
by the construction.
2.0 Septic Tank:
2.1 The existing septic tank must be properly abandoned by thoroughly pumping, removing the top
and backfilling with soil.
2.2 The new 1250 gallon, 2 compartment STEP tank shall be Municipally approved and shall be set
level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a 4"
cleanout. The STEP tank shall be fabricated of 10 gage steel and certified by the manufacturer as being
designed for burial up to 10 feet deep.
2.3 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The
waste line from the residence to the septic tank shall have a minimum slope of 1/4'" per foot. A cleanout
shall be installed within 5 feet of the building foundation.
3.0 Lift station:
3.1 The lift station shall be installed in the second compartment of the STEP tank. The lift station
package shall be an "Orenco" system as supplied by Anchorage Tank.
3.2 The contractor shall be responsible to obtain the necessary Municipal electric permit and
inspection, and shall provide a copy of the electrical inspector's report to the engineer overseeing the
construction of the wastewater disposal system.
3.3 The lift station shall be equipped with a watertight, insulated manhole riser and cover extending a
minimum of 6" above final grade with positive surface drainage away from the manhole. The contractor
shall be responsible for determining the necessary length of the manhole riser.
3.4 The on, off, and alarm floats shall be set at the elevations specified by the lift station supplier, and
their proper operations shall be verified by the contractor.
3.5 The discharge line from the lift station to the soil absorption system shall be 1.25" dia. Sched 40
PVC. Special care shall be taken in backfilling around the ends of the STEP tank to ensure that the
discharge line will not be sheared off as the backfill material stabilizes. All pipe connections in the
distribution system shall be glued, and the ends of all pipes capped.
4.0 Soil absorption system:
4.1 The soil absorption system shall be constructed by excavating a trench to a depth of 9 feet below
ground level in the approximate location shown on the site plan.
4.2 The bottom of the excavation shall be level. Any compacted or smeared surfaces shall be raked to
allow proper inffitration.
4.3 A total of 6.5 feet of approved sewer gravel shall be placed in the bottom of the excavation with
the perforated distribution pipes laid level such that the pipe inverts are no less than 6.0 feet above the
bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing
the #200 sieve. The horizontal distribution pipe shall be 1.25" diameter Schedule 40 PVC, with 3/16"
diameter holes drilled in the bottom on 2' centers, starting one foot from each end. The ends of the
horizontal distribution pipe shall be capped, and all PVC joints glued with solvent cement.
4.4 Monitor tubes shall be of 4" diameter and installed in the locations shown on the design drawings.
The portion of the monitor tube extending through the sewer gravel shall be perforated.
4.5 Approved f'flter fabric shall be placed over the entire top surface of the sewer gravel. A minimum
of 2 feet of soil cover is to be placed over the filter fabric. If the soil cover thickness is less than 3 feet,
two inches of rigid, burial type insulation is to be placed over the entire top surface of the gravel, in
addition to the filter fabric.
4.6 The top .surface of the cover material shall be raised a minimum of 12 inches higher than the
surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill
slopes shall be no steeper than 3:1.
4.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have the
site finish graded after the backfill material has stabilized, and for placement of any necessary topsoil and
seed to promote revegetation of areas disturbed by the construction.
5.0 Inspections:
5.1 A minimum of 4 engineering inspections will be required during the course of the project: (1)
initial stakeout with the contractor to establish the location of the system and to discuss the plans,
specifications and construction procedures, (2) after the native material has been excavated to expose the
inf'fltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test
information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected
up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and
grading is complete. The STEP tank requires one inspection after it is set level and the piping connected,
but prior to backfill. This inspection may be incorporated with any of the above inspections.
5.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in
advance to ensure the availability of the engineer.
TEST HOLE
LEGAL DESCRIPTION:
DATE PERFORMED:
PERFORMED FOR:
DEPTH --
(feet)
1
F.S
12-
FLATFOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
LOT 7, CHALET TERRACE
APRIL 26, 1995
ED JANZEN
Gravel fill for parking area
GP/GM or SP/SM
Somewhat silty
Sandy Gravel
(Dry)
Water
SP Medium Sand
SLOPE SITE PLAN
EXISTING
3 BDRM HOUSE~ii
HOLE
Depth to Groundwater Date
22' - 0" 4/?.6/95
20' - 0" 5/4/95
Clock Net Time Percometer Net Drop
Date Reading Time (minutes) Reading (inches)
4/2,6 12" Presoak (5 gal) 3:18:45 28
3:19:45 1 22 1/4 5 3/4
3:20:45 1 20 2 1/4
3:21:45 1 18 3/4 1 1/4
Add water & Start 3:29:25 23 1/2
#1 3:30:25 1 21 34 1 34
Add Water 3:31 23 5/8
#2 3:32 1 22 1 5[8
Add Water 3:32:20 23 3/8
#3 3:33:20 1 21 7/8 1 1/2
Add Water 3:33:45 23 1/2
#4 3:34:45 ! 22 1 1/2
Saturated
~ Impermeable Silt
B.H. 30.5' PERCOLATION RATE 1 (minutes/inch) PERC HOLE DIAMETER 8
TEST RUN BETWEEN 3.0 FT AND 3.5 FT
COMMENTS: Test Hole drilled by Discovery Drilling to assess vertical separation between bottom of undocumented seepage pit and groundwater.
Perc test conducted in separate hand dug hole located 20 feet east of test hole to determine perc rate of material encountered between 2' and 23'.
PERFORMED BY FLATTOP TECHNICAL SERVICES. I ~ ~ CERTIFY THAT THIS TEST WAS PERFORMED iN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: /~/~' ~Z /~-
uozu~z~o uu:u~ '~'uu? ~ZZ ~403 R~l CONS~T__AzNT$ ~002/002
CLIENT/PROJECT: Fl~t-top Technlca! Services
TEST ON: ~halet Tet~=.:-e field sample
SOURCE: Native soil
SAMPLED FROM: Chalet Terrace
LOCATION: Lot,#?
SUBMI E iF_O BY: _client
DATE SAMPLED: 4126/95'
DEPTH: -3.5'
R&M PROJECT: 551003
LAB NO.: 5041
FIELD NO.: 1
DATE REPORTED: 5/9/95
DATE RECEIVED: 514/95
GRAIN SIZE DI~FRIBUTI0N
sIEVE SPEC,
5'
4"
3'
2"
1 112"
1"
3/4' 80
112' 72
3/8"
#4
#8
#10 33
#16
#20
#30
#40 13
#50
#60 8.6
#8O
#100 6.5
#200 4.8
.02MM
.00$MM
.O02MM
+ 10
+3
GRAVEL
% SAND
% SILT
CLAY
CLASSIFICATION
UNIFIED AASHO
51
44.2
4.8
CLASS
~ 6o
I0
0
100
FAA
TOTAL WT. TESTED:
COMPACTION
OPTIMUM MOISTURE:
ORY DENSITY.
ORGANIC CONTENT %:
L.A. ABRASION LOSS:
REMARKS:
DRY DENSITY:
MAX. DRY DENSITY-'
% FRACTURE:
MrrHOD:
NATURAL DENSITY:
NATURAL MOISTURE:
WEIGHT LOOSE:
WEIGHT RODDED:
GRAIN SiZE OtSTRIBUTION CHART
I'0 1 0.1 0.0~
GRAIN SIZE {mm)
1.350 GMS.
MAT.
FR~ME#T$
i MG. OR ~,T.~.PT.
LUM~
~0~
6.8%
0 00~
Tested By: CLP Checked By: DKJ
C~ & EN~ON~NT~ ENG~EER~G · ENERGY CONSERVA~ON & ~YS~
TI~ODORE F. MOORE, P.E. 14550 ECHO ~T.
PH: (907) 345-1~5 ~CHORAGE, ~KA 9951~
May 10, 1995
Alaska Department of Environmental Conservation
Anchorage District Office
800 E. Dimond Blvd., Suite 3-470
Anchorage, AK 99515
RE: Separation Distance Waiver between Chalet Terrace Class "A" well & L7, Chalet Terrace
septic system.
Dear Sirs:
By means of this letter we are requesting a waiver allowing the proposed septic system
upgrade on Lot 7, Chalet Terrace S/D to be 150 feet, instead of the currently required 200 feet from
the Class "A" well which serves that subdivision. In addition to this narrative, a site plan,
proposed septic upgrade construction plans and specifications, soils log with perc test results,
sieve analysis, and copy of the driller's log for the Class "A" well are enclosed to assist you in
your evaluation of this waiver request.
The well serving this subdivision was completed in December of 1971. The water system
plans which were submitted to GAAB for approval prior to construction specified that minimum
separation distances of 80 feet from septic tanks and disposal fields and 120 feet from seepage pits
would be maintained from the well. These distances applied to a "semi-public" well category
which was in use at that time. The sewage disposal system permits for lots in this subdivision
reflected those minimum separation distances. The original septic system serving Lot 7 was
installed in January of 1972 in compliance with those minimum separation distance criteria.
Several years later the community well was reclassified as a Class "A" public water system.
This meant that the minimum separation distance requirement suddenly increased to 200 feet
between the well and both septic tanks and soil absorption systems. Because the well is located in
the center of'the cul-de-sac at the east end of Chalet Court, five of the lots in the subdivision
(including the subject lot) have little or no area outside the 200 foot well radius.
When the original septic system serving Lot 7 failed in June of 1985, AECS conducted a
soils test and submitted a waiver application to allow the system to be upgraded. I was unable to
find any correspondence indicating whether this specific application was approved or denied,
however later that month DEC sent a letter to the water system operator informing them that the
water system as a whole was not in compliance with State requirements. It appears that an
upgrade to Lot 7's septic system was installed anyway, however we were unable to find any
documentation describing the nature of the upgra~le. Two years later DEC re-reviewed the water
system plans and issued a Public Water System Operation Certificate for the water system.
In April of this year we were requested to conduct an adequacy test of the wastewater
disposal system serving the residence on Lot 7 as the first step towards applying for a Health
Authority Approval (HAA) certificate. The partially undocumented wastewater disposal system
passed its adequacy test, however in order to demonstrate the required vertical separation between
the bottom of the 23 foot deep undocumented seepage pit and seasonal high groundwater we then
had to drill a test hole and install a monitor tube. Unfortunately, this test hole demonstrated that
the present system does not have the required vertical separation, so it will be necessary to upgrade
the system. The enclosed design is being submitted to the Municipal Health Department for their
issuance of an upgrade permit, but concurrently with that we need to obtain your approval of a
separation distance waiver allowing the system to be installed as close as 150 feet from the well.
As is evident from the enclosed soils log, the shallow soils in this area consist of a
somewhat silty sandy gravel down to approximately 23 feet. This is underlain by 6 feet of
saturated sand above an impermeable silt confining layer. Based on groundwater monitoring
conducted through breakup of this year, we determined that the season high groundwater level is
approximately 20 feet below ground surface. The proposed upgrade will maintain a 10 foot
vertical separation between the bottom of the soil absorption trench and seasonal high groundwater
which should result in excellent filtration of the effluent before it encounters groundwater. We feel
that this added vertical separation should more than compensate for the fact that the soil percs a
little faster than 1 minute per inch. In light of recent experience in the Anchorage area, we expect
the proposed trench type system should function significantly better and longer than a shallow bed
or drainfield type system.
The driller's log for the Class "A" well indicates that there is an impermeable barrier
between 25 and 43 feet below ground level which should provide good protection for the water
bearing aquifer at 47 feet from any contamination introduced into the shallow soils above 25 feet.
The fact that the static water level in the well is reported as being 5 feet below ground surface
indicates that the aquiver is conf'med and artesian, and thus well protected from contamination.
The topography in the area of the proposed system slopes down from east to west at
approximately 15%. Further downhill the slope flattens and trends more towards the northwest.
The following is a breakdown of how waiver analysis points could be assigned using the 1985
"Separation Distance Waiver Guidelines for SCRO". Because the aquifer is confined, we have
used the 47 foot aquifer depth as the relevant water table to be considered.
Category Points
Depth to water table (47')
Soil sorption ((25' x 2.5) + (22' x 6))/47' --
Permeability ((25' x 1) + (22' x 3))/47' =
Water table gradient (- 10%)
Horizontal separation (l~O')
Total'
5.2
4.1
1.9
1.2
17.4
Based on the above point assignment, it appears that the requested waiver can be safely
granted without undue concern as to possible contamination of the well from the proposed
wastewater disposal system upgrade on the subject lot. In addition, it should be recognized that
the requested waiver is only 25% of the total distance, and that the proposed upgrade will optimize
the available separation distance on this lot, as well as being a significant improvement over the
original separation distance and separation distances on adjacent lots.
Please give me a call if you have any questions.
Sincerely,
Ted Moore, P.E.
JV~-'V~,/ DRILLING, inc.
P. O. Box 4-1728 e 2811 Dawson
A C 907-279-1741
Ai~CHORAGE, ALASIgJk 99509
DRILLING LOG
Chztet Terrace Subdivision Use of Well
Vgell O~vner
Location (address of: Township, Range, Section, if known; or distance main road
Hill!side ~i'i_ ye
Do_~
Size of casing 6 Depth of Hole
Static water levet 5 ft. (~'~.'~iy
~_.~eree~__~r_ .... ~.); Perforated (
feet Cased to '~ feet
(below) land surface. Finish of well (check one)
open end (
x );
Describe screen or perforation !~qs:
%Vell pumping test at 7Z~ gallons per (hour)
of drawdown from static level.
!8 Dec 71
Date of completion
(minute) for
hours with 10r"~
ft.
WELL LOG
Depth in feet from
~-ound surface
Give detnil~ of formations penetrated, size of material, color and hardness
O TO
?y .TO
~ .TO
~7 TO
,TO
TO
TO
.TO
TO
.TO
.TO'
TO
__.TO
~TO
_ r _~ring
1 -- CUSTObI]ER
GRLJ, TLR ANCHORAGE AREA BOROUGH
~epc~riment of Environmental Quality(~J~--~T[::R ANCHO~G In k[~[:k BOROJ3,~H
3500 Tudor Road -- Pouch 6-650
A~ncho'r~tge, Alc~ska 99502
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
N.o
968
NAME
LOCATION
SEPTIC TANK:
DISTANCE FROM WELL
LIQUID CAPACITY
MAILING
ADDRESS
LEGAL DESCRIPTION ~__~.7-' ~
PHON E~/~
GALLONS.
NUMBER OF
MATERIAL ~ ..,:~'--~-'-'- COMPARTMENTS
LIQUID
INSIDE LENGTH ~ INSIDE WIDTH ~ DEPTH
SEEPAGE SYSTEM:
NUMBER OF PITS /
LININg MATERIAL'~2~''
SEEPAGE PIT:
OUTSIDE DIAMETER
/ J
NEAREST LOT LINE
/ OR WIDTH /.~l~._~. , LENGTH /-~-~ , DEPTH
· DISTANCE FROM WELL ~--~;)/P~-/~'-~'~/~//-"~¢~ , BUILDING FOUNDATION
TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~ ¢"J~J/'~ ~' SQ. FT.
TILE DRAIN FIELD:
DISTANCE FROM WELL ~N N~ST LOT LINE
NUMBER OF LINES //~D STANCE BETWEEN LINES TRE~CHWIDTH
ABSORPTION ARE~ SQ.F,. LENGTH OF EACH LINE ~
DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE
TOTAL LENGTH
OF LINES
IN. TOTAL EFFECTIVE
IN. ABOVE TILE
WELL:
LOT LINE
~-DISTAN CE FROM
TYPE ~',,"~",.'~',~../~J-'~ ~ DEPTH ~ , BUILDING FOUNDATION
NEAREST SEPTIC SEEPAGE
/ SEWER LINE ,'*~F~I~NK ~ SYSTEM
WATER
SAMPLE
CESSPOOL
~ NEAREST
OTHER
~-~, SOURCES
DISTANCES:
[#
DIAGRAM OF SYSTEM
DATE
APPROVED~
· ' HEALTH AUTHORITY
ANCHOrAGe AReA BOr, OUGH
3500 TUDOR ROAD POUCH 6-6~O
ANCHORAGE, ALASKA 99502
TELEPHONE 279-8686 ~.~
SPOSAL SYSTEM ~ APPLICATION AND PERMIT
INSTALLATION Of: SEPTIC TANK ~/ SEEPAGE PJT Y
FINANCED THROUGH / TO BE INSTALLED BY
SOIL TEST RESULTS
/~RAI N FIELD
OTHER
NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
COMPLETION DATE ANTICIPATED
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TANK SIZE
MINIMUM DISTANCES, REQUIREMENTS
/
FOUNDATION TO SEPTIC TANK '~
FOUNDATION TO SEEPAGE PIT ~//{~'~
/~ /
SEPTIC TANK TO SEEPAGE PIT WALL
. SEEPAGE PIT
SEPTIC TANK ,/
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK
DRAIN FIELD
WATER MAiN TO SEPTIC TANK
DRAIN FIELD
DRAIN FIELD
, DRAIN FIELD
/
/ z~;
SEEPAGE PIT
ALSO CONSIDER AREA WELLS.
/~
SEEPAGE PIT
///;/:;
, DRAIN FIELD
/6 '
DIAGRAM OF SYSTEM
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INIT0 UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUG~I~EGULATIONS REGARDING INSTALLATION.
&
~ LICENSED DESIGNER
4
I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREA~AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
DESCRIB~) SYSTEM IS IN ACCORDANCE WITH SAID CODE. ~ ~~. ~)
DATE' .i'r ?/ APPL,CANT'S S,GNATURE ' .--
~
CASE
Performed~For x - '-: . .... Date Performed.
Legal Desuz'ip{~'bn -' "-" : ~' ~~ -
This Form Reports a: Soils Lo~: '--'--..__~ '~~t'T~,n
Depth
Feet
Soil Characteristics
Was gmound Wate~ Encountered?
if Yes, At What Depth_._~
Reading Date Gr.oss Time Net Time Depth To H20
Location Sketch
Net Drop
Fr°F°sed Instal~'~~SeepaKe Pit gPain Field
Depth Of' inlet ~ Depth '?o Bottom Of Pit Or, ']'penc~
f
'.':
,: ....... ', .... .~..~-, -~.,.,~'~,?~'.~?~
' - ' ~:~:7;'~CERTIFICATE 6E'H~LTHAUTHORI~
"~;~': ' ~':~':~'
~ ::: :ParCel I~:
Complete legal descr,pt,on.-
. ~': ';!i ~' .'.:~ ;:.-"q LocatiOn (site address; °rdirections):~'~'~ ''''75'/~ (---~ ~ ~
.....~,]* ../;. '...._,.~ ':' "~ ?'..L. _... ,: :.-..,:.~'...:~.~..~...~.: .......... ~,- ':~*'~)~'"A~;Z~A*''~ ~ ~ ~'~ ; ." .' '~:~. '*~'~ A'., -. ' · - ?.~,t., ~;.. Z..,-, ".~'*F~:¥~;;} :~[~.~F~(~i',;"' :-' ':'::- ' ""'
,::. : ~, .. -. Lending agency-.' ....... -~ ' ~-':-::':::':- ',:--:,:.:~:~'~,:,:.:.:",::"~;:' ':' Day phone .......
. , .- ~.~;~ ....... .. ....
.... ~ ~:i:~j?:,. ~~~ lnoiviOUal Well~~-~,-,~----~ ........................ .,. ~ .:.~
:: '-:t ~:. t ~::.:::~: ,~j',:; NOTE:/t:~: If cO~U~i~ well;system;?proVide wN~en* confirmation from- State ADECa~est- :~ '~;~.~ :~:=~'~:::
5. : STATEMENT OF INSPECTION BY ENGINEER:
As certified_by, my seal affixed hereto and as of the y; ~t datio~ below, I verify that my
inveStigation of this Health Authority Approval application shows that the.on-~site water supply
and/o r wastewater disposal system is safe, functional.and adequate for the nUmber of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the. Municipality of Anchorage fiie~'a"i~] fr'°~ i~iy in'Ws~i~a~i'~i' ~nd ins'~J°i~[-~:he On-site water
' supply and/or wast·Water disposal system is in compliance with all Municipal and State codes,
: '-rordinances, and regulations in effect on the date of this inspection'~~,~''~]' ~',~ -~'~'.~ .~"~,~.u,~(
SIGNATURE
"' '-::. '"~'~:'~'~'~':;'~: .... '~'.~'Date'~¢'~-~ ~7~ ~" .-.
Depa~ent of: H~lth .and Human Se~l~s (DHHS):~ues Health Authon~
only ~pon' the mp~n~tions give~..m p~p~fi~ve by an independent
~ in~itution, in omar to ~ti~ ~in f~ml ~nd ~mt~ i~mm~nB, fim~y~'Of ~HHS do not
.... ~; or anai~o dam ~toma ~fl~t~.~ ~u~.~TheMume~Pah~,o[.Anehom~ ~ not
- .~,?.~ ~!b~ lot ~om or omi~ion~ in th~ prot~ional ~n~in~e~ ~o~.~ ?z~,~:''~, .-':~ -4:~-~::-?:%::~:~.~-- ~::. ~ ~:- - '
, .:~g¢7-~ ,
Municipality of Anchorage
Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description:
A. Well Data
Well type
Log present (Y/N)
~o/~ 7~ CJ~/E/' 7~rc~c~, ParcelI.D.
If A, B, or C, attach ADEC letter. ADEC water system number
Date completed Driller
Total depth
Sanitary seal (Y/N)
Cased to
FROM WELL LOG
Nitrate
Tank size
Date of test
Static water level
Well flow
Pump level1
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot
Absorption field on lot
Public sewer main
Sewer service line
WATER SAMPLE RESULTS:
Coliform
Date of sample:
B. SEPTIC/HOLDING TANK DATA
Date installed
Casing height
Wires properly protected (Y/N)
AT INSPECTION
g.p.m.
g.p.m.
; On adjacent lots
; On adjacent lots
Public sewer manhole/cleanout
Petroleum tank
Collected by:
Other bacteria
Compartments
Cleanouts (Y/N) Y
High water alarm (Y/N)
Date of pumping N./4.
Foundation cleanout (Y/N)
Alarm tested (Y/N)
Pumper /q. 4.
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot -- On adjacent lots 15..5-'
To property line ?. "'/' I( '
Surface water/drainage ~
Depression (Y/N)
Foundation '~d' '
Water main/service line '~> I 0 '
Absorption field
72-026 (3/93). Front CONTINUED ON BACK PAGE
C. LIFT STATION
Date installed
Size in gallons
Vent (Y/N) Y
High water alarm level
Meets MOA electrical codes (Y/N)
df~c' /
"Pump on" level at
7'
Manufacturer /~c/,or~v~a -/'aol~ // ~Trva ¢ o
Manhole/Access (Y/N) Y'
" "Pump off" Level at 3~"
Cycles tested '/- ~ N. 4. (. N< ~)
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot - On adjacent lots
Surface water '~ too'
D. ABSORPTION FIELD DATA
Date installed d' / ;~o/9-'-
Length ~ ~'
Total absorption area
Date of adequacy test
Water level in absorption field before test
Peroxide treatment (past 12 months) (Y/N)
Soil rating (GPD/FF) h o
Width E~. .5-' Gravel thickness
ff ,~] Cleanout present (Y/N)
N.~4. ( N ~..~ Results (pass/fail)
.System type
0", Y' Total depth
)" ( ~, 7:.~.) Depression over field (Y/N)
Pc.o- for
After test
If yes, give date /,~. ,4
tv
Bedrooms
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot -
To building foundation
On adjacent lots '~> ,70'
Surface water ~ t co'
On adjacent lots I 0"O' Property line
To existing or abandoned system on lot t~'
Cutbank 5"~' Water main/service line > ~'
Driveway, parking/vehicle storage area ftC) '
Curtain drain
E. ENGINEER'S CERTIFICATION
I ce~'fy that I have checked, verified, or conformed to all MOA and HAA guidelines in effect ~Z~~_~Z this inspection.
Signature ~~ ~ ~ ~,,,,,, ..... ,,,,,,,,,,,~t~..~
Engineees Name ~ eo ~o r~ ~. ~oo~( · ~ . .: . ·
Date ~ f ~ / ~ ~:::;?"- -'" ~
HM Fee $ N, h.
Date of Payment
Receipt Number
Waiver Fee $
Date of Payment
Receipt Number
72-026 (3/93)* Back
,,.~, ? .. MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES -
Division of Environmental Services
· · :*~ ..... "' "*' ': On-Site Services Section
......... ~' ~ ~ r' -- '~'' P.O. Box 196650. Anchorage, Alaska 99519-6650
; .;., .'_.: ......... . .:_ ....... ~ ..'.. 343-4744, - - .
............. CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
1. GENERAL INFORMATION ....
Complete legar description /-o/- 7~
Location (site address or directions)
Day phone
Day phone
.... .!?A~ent.-/:.yn ~ ' .l~=cr~ ,. [?~z~ ~ 1=~,o., ~t ( ~ Day phone
Unle~ ot~e~ise ~quested~ HAA will be held for pickup. -~:- ~.,~:~ :~::~:.~u~..- ~ ;~:..._-~.~:-. '...--
....... NOTE: ....If communt~,ll *Y,~,m, provtdo ~i~o~ confirmation'from
'J ~ ing tO ~e' legality and status of system.
4.: ~E OF WASTEWATER DISPOSAL:' '.3 .... ~.-,.' ':~ , ,
IndiVidual on-site ~ ,:'
' ' ~ ....... ~'~' ' ,,'-~UDIICS~wer--' .... _ ' -:'~
'-NOTE: If commUnity Wastewater system, provide wri~en confirmatidn' fro~'Sta'te' ADEC
":'" ~" "::':"::~::':':' a~e~ti~g-~,..~ .~=.,.,~ -~"~an~ status of ~,~,,,~,,~*~. . ...... ~. ......... ~,~..z~-:,_??'
72~5(R~.1~1) Front MO~
STATEMENT OF INSPECTION BY ENGINEER ~ ~ ~..,-.
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances.' and r gulatipns in eff~ect_o_n_the d. ate~of this inspection. . ~,,~ ,~,A~,r!.
Address /y~ 3d' ~Ec~ ~F.~ ./)~c~,,',~..~/ /er-~< ~9,,5-/~'
Engineer's signature ~'~ ~'' ~ Date ~-/~-~'/
._. 6.;:'; DHHs _'SIGNATURE -
":':':--'- ~ :: cO-nditional approVal 'for
- ~r~oms, with the foli~wing~tipulations:
--~ :., .Additional Comments ~P~ /~
..' ,~(,I 9 >:".,, '"'
~- '~he Munie~ali~,~An~homge ~pa~ent of Health and Human Se~ic~ (DHH~) ~ues Health Authon~
'%Apprqval ~f~te~ b~ only u~n the mp~entatlons gwen m pamgmph 5 abo~ by an mde~ndent
~rof~i~al e~in~r r~iste~ in the State of Alaska. The DHHS d~s this ~ a ~u A~y to pumh~ of hom~
and their lending institutions in order to ~tis~ ceAain f~e~l and s~te r~uimmen~. Employ~ of DHHS do not
conduct inspections or anai~e data ~fom a ceAifi~te is i~u~. The Municipali~ o~, Anchorage is not
~pon~ible for e~o~ or omi~ions in the pmf~ional engine,s ~o~'~
~ (~. 1~) ~
Municipality of Anchorage
Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description:
A. Well Data
Well type
Log present (Y/N)
Total depth
Sanitary seal (Y/N)
If A, B, or C, attach ADEC letter. ADEC water system number
Date completed Driller
Cased to Casing height
Wires properly protected (Y/N)
FROM WELL LOG
Date of test
Static water level
Well flow
Pump level1
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot
Absorption field on lot
g.p.m.
AT INSPECTION
RECEIVED
g.~,~.Y 2 6 'i995
Municipality ol ^nct~o~ ~,ge
bep[. Health & Human Service~
; On adjacent lots
; On adjacent lots
Public sewer main
Sewer service line
WATER SAMPLE RESULTS:
Coliform
Date of sample:
B. SEPTIC/HOLDING TANK DATA
Date installed ?~ o_ro N
Cleanouts (Y/N) '/"
High water alarm (Y/N) ~'
Date of pumping /¥./~.
Public sewer manhole/cleanout
Nitrate
Petroleum tank
Collected by:
£ 7EP
Other bacteria
Tank size I ~5'~' ~t
Foundation cleanout (Y/N)
Compartments
Alarm tested (Y/N)
Pumper
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
On adjacent lots
Absorption field
Depression (Y/N) /v
Well(s) on lot ~,1. ,4
To property line '~ O
Surtace water/drainage
Foundation
Water main/service line
72-026 (3~3)* Front CONTINUED ON BACK PAGE
C. LIFT STATION
Date installed
Size in gallons m
Vent (Y/N) Y'
High water alarm level
"Pump on" level at /,pt r
Meets MOA electrical codes (Y/N) u~', i/ r"~'. ;,,~(p
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot N. ~4. On adjacent lots
D. ABSORPTION FIELD DATA
Date installed P ~o {~ ~c~
Length $ Z; ' Width
Total absorption area 5/ ~-d"
Date of adequacy test N./~.
Water level in absorption field before test
Peroxide treatment (past 12 months) (Y/N) --
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot ~, ,4. On adjacent lots
Manufacturer O
Manhole/Access (Y/N)
rh ~ ~ ~, ~¢/~ ~' ~'Pu mp off" Level at
Cycles tested N.A.
Surface water
Soil rating (GPD/FF) I, o System type "Tr'~,~ ¢/~
'~. 5"' Gravel thickness d', (2 Total depth ~ .~
Cleanout present (Y/N) Y' Depression over field (Y/N)
Results (pass/fail) for 3
-- After test -
If yes, give date -
I ~-0' Property line I 0 '
Bedrooms
To building foundation
On adjacent lots '> 3~"
Surface water ~> ~ c,o'
Curtain drain h/o~
To existing or abandoned system on lot
Cutbank /,4. ~4. Water main/service line
Driveway. parking/vehicle storage area '> 5-~ '
E. ENGINEER'S CERTIFICATION
, ce~'fy that I have checked, verified, or conformed to all MOA and HAA guidelines in effe~'~.~~,? inspection.
Signature o~~ ~. ~ ~~ii~'o~
Date t~ ~ ~ ~ /~ ~- ', ~;~_', .... ~ ~'
HAA Fee $
Date of Payment
Receipt Number
Waiver Fee $
Date of Payment
Receipt Number
72-026 (3/93)* Back
CIVIL & ENVIRONMENTAL ENGINEERING · ENERGY CONSERVATION & ANALYSIS
TIIEODORE F. MOORE, P.E. 14530 ECHO ST.
PH: (907)345-1355 ANCHORAGE, AL~KA 99516
RECEIVED
MAY 2 6 1995
Munic~pahty o~ A~chorage
Dept. Health & Human Services
TONY KNOWLES, GOVERNOR
DEPT. OF ENVIRONMENTAL CONSERVATION
ANCHORAGE/WESTERN DISTRICT OFFICE
800 E. DIMOND BLVD., SUITE 3-470
ANCHORAGE, ALASKA 99515
(907) 349-7755
May 22,1995
Mr. Theodore F. Moore, P.E.
Flattop Technical Se~ices
14530 Echo St.
Anchorage, AK 99516
RE:
Lot 7'Chalet Terrace Subdivision. Horizontal Separation Distance Waiver Request
Between a Class "A" Well (Chalet Terrace PWSID no. 211106) and Proposed
Replacement Septic System. ADEC project no. 9521-WV-130-040.
Dear Mr. Moore:
This letter is in reference to the materials received in this office May 10, 1995, requesting
a waiver from the minimum separation distance between a proposed replacement septic
system and the above referenced class "A" well. The Department has completed its
review of the submitted materials which included a cover letter with justification for
requested waiver, engineered plans of the septic system upgrade, and a well log. Based
upon this review it appears that a waiver may be granted in accordance with State
Drinking Water Regulations (18 AAC 80.030) subject to the following comments:
The proposed system is not expected to pose a greater contamination
source than the existing undocumented system. There are currently
several systems within the required 200 foot protective radius of the well
and analysis of nitrate levels while detectable have been steady.
Reconfirm the percolation soil rate during excavation of the on-site
wastewater disposal system. Trench designs require soils with a
percolation rate not less than 1 minute/inch.
3. Construction and installation activities must be monitored by a
professional engineer (P.E.)..
Thank you for your cooperation with this Department, if there any additional questions
regarding the above please do not hesitate to call.
ML/pt
Sincerely,
Michael Lu, E.I.T.
Environmental Engineer