Loading...
HomeMy WebLinkAboutFIRE LAKE BLK 3 LT 9AFire Lake Block 3 Lot 7A & 9A #015-361-20 015-361-27 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP251233 Work Type: Septic Upgrade Tax Code Number: 05136127000 Site Legal Address: FIRE LAKE BLK 3 LT 9A G:0453 Site Mailing Address: 18034 MACLAREN ST, Eagle River Owner: ALBA RESTORATION LLC Design Engineer: FORGE ENGINEERING This permit is for the construction of: Z Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date: 7/29/2025 7/29/2026 Lot Size in Sq Ft: 31450 Total Bedrooms: 10 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1. This property recently sold without the benefit of a COSA. Please apply for a COSA for this property per 15.55 and 15.65 in order to close out this permit. 2. Confirm location of water well on FIRE LAKE BLK 3 LT 7A prior to construction. 3. A test hole is required prior to construction of the absorption field, in the location shown on the site plan, to confirm minimum separation to impermeable soil and seasonal high groundwater, as well as percolation rate. Construction may proceed at your own risk prior to 7-day groundwater monitoring. If results require a design change, construction shall stop pending approval of a change order. Please submit results with the inspection report (or change order, if required). Received By: Date: j Issued By: i/ Date: MUNICIPALITY OF Development Services Department On -Site Water & Wastewater Section C* ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051-361-27 Phone: 907-343-7904 Property owners) Alba Restoration LLC Day phone 907-521-9777 Mailing address 741 West 75th Ave #3, Anchorage, AK 99518 Site address 18045 Mendenhall St Legal description Fire Lake, Block 3 Lot 9A Number of Bedrooms 10 Engineering Firm Forge Engineering Building Permit Number Not Applicable ❑ APPLICATION IS FOR: APPLICATION IS AN: (Z all that apply) Absorption Field 0 Initial ❑ Septic Tank El Upgrade Holding Tank ❑ Renewal ❑ Privy ❑ Well ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: Permit/Rush Fees: t Sq S Waiver Fees: Date of Payment: 71141 Date of Payment: Permit No. 02fl)33 Waiver No. July 28, 2025 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Fire Lake, Block 3 Lot 9A – 18045 Mendenhall St Septic system design Dear On-Site Services Engineer: The owner of the above lot owns an 8-bedroom and a 2-bedroom house on this lot. The existing septic system is too small to serve the bedroom count, so we are submitting this permit application for the construction of a new septic system. The attached site plan identifies the location of the home as well as the proposed septic location. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot has a mild slope from the east to the west. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. The existing plot plan shows the gravel driveway in the area where the new septic system will go. Although it’s possible that the drive will be shifted away from the septic in the future, we have specified 4” of insulation over the trench while under the driveway. Typically, 1” of insulation is considered to provide the same frost protection as 1’ of soil. With 4” of insulation, and 3’ of cover, the lateral for the trench will have the same frost protection as minimally required for a public sewer line (6’ of cover). This will be sufficient to prevent freezing under the driveway. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251233, Curtis Townsend, 07/29/25 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND FIRE LAKE, BLOCK 3 LOT 9A FEET 0 50 100 8-BDRM DUPLEX SEPTIC PLAN 7/8/25 MENDENHALL ST 10' UTILITY EASEMENT 438 436 434 432 430428 426 424 422 FIRE LAKE ELEMENTARY SCHOOL HARRY J MCDONALD MEMORIAL CENTER VACANT ALL NEARBY WELLS SHOWN WITH 100' RADIUS DECOMMISSION EXISTING TANKS 3000-GAL STEP TANK (2) 65' LONG X 5' WIDE, 4' EFFECTIVE DEPTH TRENCHES 2- B D R M INSTALL FCO TH#1 MTMT MT MT FCO ENSURE 100' SEPARATION FROM EXISTING WELL EXCAVATE TRENCH, REMOVE ALL ROCK AND BACKFILL WITH IN-SITU MATERIAL FCO ENSURE 10' SEPARATION FROM FOUNDATION TO TANK CONFIRMATION TEST HOLE TO BE DUG PRIOR TO INSTALLATION ADD DRIVEABLE CAPS OVER MT'S WHERE IN DRIVEWAY Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251233, Curtis Townsend, 07/29/25 FIRE LAKE, BLOCK 3 LOT 9A TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER DESIGN FACTORS:SYSTEM REQUIREMENTS: 1500 GPD PEAK FLOW PERK RATE: 5.0 MIN/IN APPLICATION RATE: 1.2 GPD/SF 5' WIDE TRENCH SYSTEM 3000-GAL STEP TANK BOTTOM OF TRENCH: 7.5' BELOW GRADE (8.0' MAX) FLOW LINE ELEVATION: 3.5' BELOW GRADE 1500 GPD / 1.2 GPD/SF / 5' WIDE * 0.5 RED FACTOR [4.0 DEEP] = 125.0 LF TRENCH REQUIRED (130.0 LF SPECIFIED) 7/8/25 4' 6" 3' GEOTEXTILE FABRIC w/ 4" INSULATION UNDER DRIVEWAY DRAINFIELD ROCK 1 1 4 PVC w/ 1 8" ORIFICES SPACED 6.5' OC PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251233, Curtis Townsend, 07/29/25 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING DEPTH TO WATER AFTER MONITORING 5.0 6/25/25 1 2 3 4 5 6SM (SILTY SANDY GRAVEL) Professional Engineers Stamp: FIRE LAKE, BLOCK 3 LOT 9A 6/25/25 051-361-27 JANI QOSJA 159 8 16 OB 10 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: JUSTIN EARLS 165 8 16 NONE 7/2/25 COMMENTS: SITE PLAN 2 3 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 7/8/25 MOISTURE NOTED AT TIME OF DIGGING?NO 2 2 16 2 2 16 2 1 16 2 2 159 8 1610 165 8 16 159 8 1610 165 8 16 159 8 1610 165 8 16 159 8 1610 165 8 16 159 8 1610 165 8 16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251233, Curtis Townsend, 07/29/25 MUNICIPALITY OF ANCHORAGE K�l Development Services Department �� % Phone: 907-343-7904 On -Site Water & Wastewater Section May 7, 2025 ALBA RESTORATION LLC 741 WEST 75TH AVE. #3 ANCHORAGE, AK 99518 Subject: Legal Description: FIRE LAKE BLK 3 LT 9A Dear Owner: Our records show that this property recently transferred ownership without the benefit of a Certificate of On - Site System Approval (COSA). This means the systems involved are out of compliance with Anchorage Municipal Code 15.55 and 15.65 (AMC). A COSA is now required to be obtained for this property. It is our understanding that a private well serves this structure and is located on lot 7A and a septic system is located on this lot 9A. Please contact our office within 30 days to inquire how to obtain a COSA. The Onsite Water and Wastewater Section will do what we can to help you make the private water and septic system approved to operate. Sincerely, Curtis Townsend On -Site Water and Wastewater Section MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE [] NEW R~_.~.~./' ~[~'-~"---~ ~'~'--~'~;~'~/ I~'UPGRADE LOCATION NO, OF BEDROOMS Well l. Absorption area Dwelling PERMIT NO, '" ~ ~, DISTANCE TO: ] /~O ~ '/] /~ / ~ / / ~ Z Manufacturer Material No, of compartments ~ [Liq. capacity in gationsV ' ~ I Insid~length ]~¢th Liquid depth ~ ~ ] D STAN-E T~ Well ' [Dwelling %} PERMIT NO. ~z ' ~ ~: I ~ ~ ~ Manufacturer ] Material Liquid capacitv in gallons Q I Well ~ /' Foundation ¢ I Nearest lot line ~ PERMIT NO,~ .~,~ ~ ~ [ DISTANCE TO: I /~ / ~0 ] /~ ~ ~ ~ Z I No, of lines Lenoth of each kine Total length of ines ¢~rench width Distance between i~es ~ ~ ~e to finish grade Material beneath tile .. Total effective absorption area ~ I ~gth Width Depth PERMIT NO. ~ I Ty~ ¢ crib Crib diameter Crib depth I Total effective absorption area ~ ] Well Buildingfoundation t Nearestlotline I TO: I ~ ]Class u ~ ~' Depth ~ Driller ~ d Di~t~.ee to lot line PERMIT NO. ~ J ~NCE TO Building foundation Se~er line / Septic t~nk Absorption ~re~(s) / OTHER PIPE MATERIALS SOIL TEST RATING INSTALLER REMARKS APPROVED 72-013 (Rev. 3 MUNICIPALI DATE LEG~[ ,:,,.-. ..... , .... ,.,T,,.E., ....... lq,~., I _. t,:." .~E~., I,,..'"'"" ....... "'l'::Lw, :~"[ ~'" ..... ~" ' -' -' :': ':'4' ,:....L_:..:L : ,_.t ,,.~ .... '.,.'£F-.'. 2;:i;4" 4?20 : ,, .,, .... . '-'" ?" ~'"-"" F"[ ........ ,~'., ...... ~Z-~; 3[ F .~:::,.. EL-. E: IL,,.t EiE I~:;~;-~ F> E." l~.". I"I X 'T PERM I T lq:EL ""'"~"'" ...... ,. ............. , II ,I, . I?f" P,I E:FITEC PI'IfL'INE: u uc,- _..,., , i,....~......~ .......... DO',::; '....ub ," [ilql]iL,,E F..'.:. I",.';E'F'_ ':.,, FII':( .... ~ ~ '[ ..... ~,.,.~ ...I..II ..... 4 .... E LFII'":K · ' ...... ~..~., .~_,.~ ........ t, , E,... FIRE LFII(E ._ L.. ,_L, ~ E; I Z.E "~ ':?' ~' "-"~' ' ~ ......,. , ,. TOI4N:3HI P: i._ N RFtNI3E: ;2H SECTION: ...,,-,,.., .~ ~..,, ,,.., ~ ~- r.,,=. ~, OF DE'.E:,RI3111M'.S = C', fi;C I L RFIT I NG = '='~i ':"~ ':'5 .... ' I ,, ,,-., ~., ,,...,, , ,, ' ,:,~ .................. ,:: S~;L FT. , E R.., LIE;TEE[:, m'i='~ '""' ' ........ ~"' ~''' ~. ........ u.,E:,I JNINJ "r'- ~' - ...... ' .... ~,,~,. ~,,..., IlL:i_ ,,I,_ OF'"FII"gI"~':;~; FI,,'-T' '~'" ~" TO ','OU IN '"='- " .. :,EF '.~','2'T'[]"t. - I'-IF F ,r' F "~" '"- ""='"' ¥ '-'" '~' ' ......... ' .... .............. I, ,,hi, E,E..,T FITS -'"' ~UNICIPALITY OF ANCHORAGE Department Health and Environmental rotection 825 L Street, Anchorage, AK. ~J501 264-4720 ?O ?) ~: HANDWRITTEN PERMIT * * * Z~~ ~-SITE SEWER PERMIT Permit Applicant: .~','~ L~"]'-J~---~ Mailing Address:._. ~)~_~7 .~2~"~.,. Location: Phone Number: Legal Description: ~' ~ ~ ' ~t Size: Type of Soil Absorption System Is: Trench: /Drainfield: _ S_~_eepage Bed~ Holding Tank: Maximum Number of Bedrooms: ..~~ Soil Rating(sq.ft/br) The Required Size of t~e Soil Absorption System Is: DEPTH ~?'' '~ ~ LENGTH . GRAVEL DEPTH ~' WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). ~X~5~ · * REQUIRED SEPTIC(HOLDING) TANK SIZE TM /~--'~f]) GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. · * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this departme~ will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 fe~ for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. · * * PERMIT EXPIRES DECEMBER 31, 1 9 $ 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as (2) (3) S igne~: set forth by the Municipality of Anchorage. I will install the system in accordance with codes. sewer system may require enlargement if I understand that the on-site include more th~ bedrooms. the mesideEce,i~ remodeled to Applicant / SWP/024(1/81) FFLI_.HN F SHAi'"IFIN CONST INC i'"iLII'-.I :[ C: ]: F"RL_ I T"'r' '_-iF= RI'-.IC:HEqF.:Rm3E [:,EF'RF.:TMENT i.- HERLTH RNE:, ENVIRONf'IENTRL .)TECTION 825 "' L STREET., RNC:HORIRGE., Ri,::. 995~-.:..'H 264-4720 SElL. lEE: F"EF-: I".1 I T SR'I BOX 3465 KLONDIKE ST 9_'9.567 688--2658 L 0 iS: FI T I 0 N LEGRL L9R E:~:-'~IGY'i~F: FIRE LRKE TYF'E IZIF qlalL HE,_-,U~.FTION -,T_,TEM IS: [:"RRINFIELD LOT SIZE 9999'~9 SO!UFIRE FEET I1H,.,IIIJtl NUMBER i3F BE[:,ROOf'IS = .$ SOIL RRTING ,::S6! FT,,"BR)= '14Ct THE RE.::qJIRE[:, SIZE OF THE SOIL HE,=,_F. FTIUN S"r'STEM IS: E::" E F" 'lr' FI = .'~1: L E I%i mZi-F H= 82 G E:R'..." E L E:,EPTH= 'THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR [:'RRINFIELD. THE DEPTH OF' R TRENCH OR PIT IS THE [:,ISTRNCE BETWEEN THE SURFRI_-:E OF THE GROUND RN[:, THE BOTTOM OF THE EXCRVRTION (IN FEET). T H E T F-: E ~-,! mS: H L.J I [:, T H I S 5. L__.'~ E'~ ~3 F E E 'IF .. 'THE GRFtVEL DEPTH 'IS THE MINIMUM DEPTH OF ORFt',,,'EL BETWEEN THE OUTFFtLL F'IPE FIN[:, THE BOTTOM OF' THE EXCFfv'RTION ,:.'IN FEET.'.',. Y.:"~;k--:'!mJ I I-~:FE) 2';EF'T I ~:: T FtI'-.Ik--'. $ I ZE= :.IL 5 v:~ ¢.::~ PEF.:MIT RF'PLICRNT HRS THE RE_,FUN:,IE, ILIT¢ TO INFORt'I THIS E:,EF'RF.:ThlENT [,_RINI3 THE IN=,THLLMTIUN IN-',FEE. TIUN=, OF RNY WELLS R[:,..TRCENT TO THIS ' '¢ ' ' FRJPEF..T~ FINE:, THE NIJMBER OF RE=,I[.EHL. E=, THFIT THE WELL WILL SERYE. ........ T I-.-I I_-). ':: '; ::, F; Z I I'-.ISF"EC:T I m_-m[-,IS F-:E F-:Em_--!LI I F~-"EE:, ........ BRIZ:KFILLINI3 OF RNY SY'-'iTEM WITHOLIT FINRL IN_-,FEUTIF~N AND RFFF._ ~L BY THIS [:,EF'FtRTMENT WILL E:E SUBJECT TO PR. OSEZ_TI_'N. PIlNII'"IUM DISTRNCE BETWEEN R WELL RND ANY ON-SITE SEWRGE DISF'OSRL SYSTEH IS · '100 FEET FOR R F'RIVRTE WELL OR 150 TO 2E~0 FEET FROM R PUBLIC WELL [:,EPENDING UPON THE TYPE OF PUBLIC WELL HINIMUH DISTRNCE FROM R PRIVRTE WELL TO R PRIYRTE SEWER LINE IS 25 FEET' FIN[:, TO R COHr,IUNITY SEWER LINE IS 75 FEET. OTHER REC..!UIREMENTS WRY RPPLY. SPECIFICRTIONS RN[.', CONSTRUCTION [:,IRGRRMS RRE RVRILRBLE TO INSURE PROPER INSTRLLRTION. F"EF~:I',I I T' E:-::P T F~E$ E:,,Em-:EI"IBEF;~: ---=:::L.. I CERTIFY THRT ±: I FII"I FRMILIRR WITH THE REO!UIREMENTS FOR ON-SITE SEWEF.:S RN[:', WELLS RS SET FORTH BY 'THE I"IUNIC:IF'RLITY OF RNCHORRGE. 2: I HILL INS'TFILL THE SYSTEM IN RCCORDRNCE WITH THE CODES. 2:: I UNDERSTRN[:, THRT THE ON-SITE SEWER SYSTEM MFIY REQUIRE ENLFIRGEMENT IF' 'THE RESIDENCE IS REPIO[:,ELE[:, TO INCLUDE MORE THRN 5 BEDROOMS. · '"~kISSUE[:' BY ~/ ._[:,RTE_ M b,~e-T ~.) 1 L) ?-/~ 'v'4. 7125 0Id Seward I-~.. Anchorage, Alaska 99502 · · 349-B561 ;. SOILS LOG -- PERCOLATION .TEST ~/ SOILS LOG PERCOLATION TEST PERFORMED FOR: '~'~, {~ ~'~ LEGAL DESCRIPTION: O-0,5 ! 2 4 5 6 .7 9 SLOPE SITE PLAN 1 10 11 12 13 14 15 16 17 18 19 6~/~V~-'"/... /~U/7'h/ ..~/~-'T Z4~..~UNTERED? IF YES, AT WHAT OF 1834,.E Reading Date Time Time Depth to Water Net Drop 20 COMMENTS PERCOLATION RATE TEST RUN BETWEEN FT AND -- FT PERFORMEDBY:~jI ~, ~,l'~Jl~ ,"~ CERTIFIEDS¥: DATE: SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST PERCOLATION TEST .EREORMED EOR: V LEGAL DESCRIPTION: [.0~ qA j IC~LOC,(~. ~, L)PPiZ/~ I=I/2E L,q,~.E %dtT. 1 2 3 4 6 7 '-----8 9 10 11 12 13 14 15 16 17 18 19 20 5 I L:-F ToP SLOPE WAS GROUND WATER S ~-;IOTY C~ Pr~4b ENCOUNTERED? /Jo L O E IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE TEST RUN BETWEEN A/ o ) COMMENTS '~L~?E ,~7' ,Pi?- ~ ~% (minutes/inch) FT AND __ FT PERFORMED BY: 72-008 (6/79) DATE: G~CATER ANCHORAGE AREA BOROI'~H HEALTH DEPARTMENT 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511 614 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE FROM WELL LIQUID CAPACITY ADDREssMAILING .~.3/./~_~/.../../..~_~.~.....;.~_. ~..~,~_.. PHONE~..~_~_..~,~ LEGAL DESCRIPTION /~-~'-~-~-' .~'~_~-; ,.,"~,~- ~..~..-J~/,~= GALLONS. NUMBER OF MATERIAL ~ ~')~7 '-~-c~"~/-~ '~ c'~-;-~' COMPARTMENTS INSIDE LENGTH //&J INSIDE WIDTH ~ /' LIQUID DEPTH SEEPAGE SYSTEM: NUMBER OF PITS / _OUTSIDE DIAMETER ~ OR WIDTH L,N,NG MATER,A, ;1 .O,S ANCE FROM NEAREST LOT LINE (~ ~ / TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) LENGTH/~/: , DEPTH ~ BUILDING FOUNDATION SQ. FT. TILE DRAIN FIELD'. /'~_//'/,/~' DISTANCE FROM WELL ~ , F~I~O DATION , NEAREST LOT LINE - \ TOTAL LENGTH OF LINES IN~F ECTIVE DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE W E L L: TYPE ~,~/~-~-Z' , DEPTH ~ i LOT LINE /~ /~ NEAREST SEPTIC SEWER LINE~ ~ . , . TANK DISTANCE FROM , BUILDING FOUNDATION./'~') /7/~ WATER SAMPLE //~'~ , NEAREST ~'/ / SEEPAGE / ---'(-~/~/~/~. OTHER.~dZ/~..~'. , SYSTEM /z/)~/~ , CESSPOOL ~/ , SOURCES~J~ DISTANCES: DIAGRAM OF SYSTEM DATE APPROVED~"~-------~'~'"~'~'~ ~' HEALTH AUTHORIIY ' GREATEI ANCHORAGE AREA ' DROUGH HEALTH DEPARTMENT 327 Eagle St. Anchorage, Alaska 99501 279-2511 SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT Case No. ,~ o NAME OF APPLICANT RESIDENCE ADDRESS LEGAL DESCRIPTION APPLICATION TO INSTALL: SEPTIC TANK ~ /~ ~¢~r~'~- MA,,,NG AOORESS ?~,~~ . PHONE NO u~", SEEPAGE PIT ~, DRAIN FIELD , OTHER TO SERVE THE FO~LOW,NG FAC, L?[ ~_T ~Z£~ ~ FINANCEO THROUGH ~-~,/t~ TO BE INSTALLED BY PERCOLATION TEST RESULTS ['~ C'~/~''~ ANTICIPATEB DATE OF COMPLETION' --c"~ ,~,..~2.~..¢.2~./~.~d. BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT THIS IS TO SERVE AS ¢;~'~7-'2, /(~:"~/~--~ , PERMIT TO INSTALL A AsDEscRIRED B Lo~b-~W. SIZE OF UNIT TO BE/SERVED · SEPT,C TAN. S,ZE /'~7~'> TYPE ~'~,~'.~SSEEPAGE AR~A DIAGRAM OF SYSTEM DISTANCES: ~/~./ Health Authority ]~certi£y that I am £amilia~ with the requ~¢ments of G~eater Anchorage A~ea Borough O~dJ~ance No. 28-68 and that the above described system is in accordance with said code. DATE APPLICANTS SIGNATURE /- ~,~ Y- ........................ / ..: / : ~ lit ....... I Al %'< ¢.~.-. ...... q, , I / A~¢ ~;-, ~L%~ ?; ~ /, / '.' ~/ 'h~',' 3'/ ~.~,' ,' ~ ~ ~ ,~: ,' , i ~ ~ / 2_~~-. - ' "< ~ -"~ -t ~ - Wthq Sed~ ~ Townsh,p 5 N~th Range~2 West DTI000333 106-12 I ] _ ~-~?,- ~"~ .... ~ i L S¢cton 36 T0w~hn 5Xorth Range 2 Wes Seward Mend~ Area: 35 69 Acres (l~,ng Tract A ) ~re Lake, Alaska D'Tt000335 r , I I