HomeMy WebLinkAboutFIRE LAKE LT 3 LT J2AOnsite File
Crib is only sized for 3 bedrooms. Prio
to f uture COSA approval, a 4-bedrool
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP191184
Work Type: SepticTank Upgrade
Tax Code Number: 05133344000
Site Legal Address: FIRE LAKE LT 3 LT J2A G:0554
Site Mailing Address: 18551 FISH HATCHERY RD, Eagle River
Owner: CHATMAN LEON J
Design Engineer: FORGE ENGINEERING
Effective Date
Expiration Date:
�i>>ent
. ii� IIS i
Dcpartmcnt
Lot Size in Sq Ft:
Total Bedrooms:
5/21/2019
5/20/2020
41746
This permit is for the construction of:
❑ Disposal Field IBJ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
4
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
rSpecial Provisions: The existing crib is only sized for 3 bedrooms. Prior to future COSA approval, a 4 -bedroom
drainfield will need to be provided or the bedroom count resolved with MOA property appraisal.
Received By:
J
Issued By:
Date:
Date: 51.2
A
;
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 051-333-44
Property owner(s) Leon & Tammy Chatman
Mailing address P.O. Box 770137 Eagle River, AK 99577
Site address 18551 Fish Hatchery Road Eagle River, AK
Day phone 701-580-2121
Legal description (Sub'd., Block & Lot) Fire Lake, Lo4-; 3, Lot J2A
Legal description (Township, Range & Section)
Lot Size 41,746 Sq. Ft. Number of Bedrooms Four
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF) ❑x
(w/wo ADU)
Septic Tank
1ZUpgrade
®
Duplex (D) ElHolding
Tank
❑
Renewal ElMultiple
Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
Water Storage
❑
❑
RIO
THIS APPLICATION INCLUDES
A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: & 3�6 Waiver Fees:
Date of Payment: ss� //9 Date of Payment:
Receipt Number: (1 J-d'g8D Receipt Number:
Permit No. 655 /9 /IN Waiver No.
Permit App__'- :-
PO BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
May 20, 2019
MOA Development Services Dept, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Fire Lake, Lot 3, Lot J2A – 18551 Fish Hatchery Road
Septic System Design
Dear On-Site Services Engineer:
The septic tank on the above lot has failed and is currently leaking onto the surface. The owner
is pumping on a regular basis to contain the effluent. We are submitting this permit application
for the construction of a new septic tank to serve the home. The attached site plan identifies the
location of the home and the existing well and septic system along with the proposed location of
the new tank. No conflicts exist between this proposed tank location and any other well or septic
system on this lot or adjacent lots.
The new tank will be placed outside the 100’ setback from the creek shown on the north side of
the lot. The tank will be the infiltrator tank supplied by Ferguson Company. It will be buried to a
depth of 6’ with the addition of Styrofoam blocks to limit the load atop the tank. The tank will
be 100’ from the well on this and adjacent lots.
Please refer to the site plan for the septic design. If this design is followed, there will be no
adverse impacts to adjacent properties.
Sincerely,
Michael E. Anderson, PE
5/20/19
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191184, Rebecca Carroll, 05/21/19
2CO
NOTE:
NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH
WELLS OR SEPTIC SYSTEMS.
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FD - FLOW DIVERTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
FISH HATCHERY ROAD
FIRE LAKE, LOT 3, LOT J-2A
1"=50'
FEET
0 50 100
4-BDRM HOME
5/20/19
20' POWERL
INE EASEME
N
T
25'
ST
R
E
AM
EA
S
E
M
E
N
T
STREAM CENTERLINE
20' DRAINAGE EASEMENT100' STREAM SETBACK
1,250 GALLON
SEPTIC TANK
w/20" MANWAY.
DECOMMISSION EXISTING
SEPTIC TANK PER MOA CODE
2CO
SV
MH
EXISTING ABSORPTION
CRIB
EXISTING WELL
EXISTING WELL
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191184, Rebecca Carroll, 05/21/19
sGRE
'"R ANCHORAGE AREA BO,. "SH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503 ._~.~.
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME
LOCATION
MAILING ADDRESS PHONE
SEPTIC TANK:
DISTANCE
FROM WELL
INSIDE LENGTH
MANUFACTURER
NUMBER OF
MATERIAL ~' ¢ ~--"~ ("'"" COMPARTMENTS
INSIDE WIDTH
LIQUID DEPTH_
LIQUID CAPACITY ,/~)~ GALLONS.
SEEPAGE PIT:
NUMBER OF PITS I DIAMETER ~" OR WIDTH 17', LENGTH HI, DEPTH l~I
LINING MATERIAL LO~. CRIB SIZE: DIAMETER ~' DEPTH ~' DISTANCE FROM: WELL
BUILDING FOUNDATION_'~..~',~ NEAREST LOT LINE ~--Ol TOTAL EFFECTIVE
ABSORPTION AREA (WALL AREA) 37
SQ. FT.
ADDITIONAL ABSORPTION
TYPE CONSTRUCTION
BUILDING NEAREST NEAREST
FOUNDATION_ LOT LINE SEWER LINE
CESSPOOL OTHER SOURCES
APPROVED DISAPPROVED REMARKS
DEPTH DISTANCE FROM:
SEPTIC SEEPAGE
TANK __ SYSTEM
DISTANCES:
INSTALLED BY:
fol t<o
0
PIPE MATERIAl ·
LOT SLOPE:
REMARKS:
Form No. LQ-031
DIAGRAM OF SYSTEM
DATE I~)//~ ~L/·~
I/
APP ROVE ,~~~G.~A.~' ~
GReATEr ANCHORAGE AREA Borough
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 "C" STREET ANCHORAGE, ALASKA 99503
TELEPHONE 274-4561
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
PERMIT NO.
MAILING ADDRESS
PHONE
INSTALLATION LOCATION
LEGAL DESCRIPTION
INSTALLATION OF: SEPTIC TANK
TYPE AND SIZE Of FACILITY TO BE SERVED
FINANCED THROUGH
SOIL TEST RESULTS
SEEPAGE PIT __, DRAIN FIELD , OTHER .
TOBE,NSTALLEDBY---
NOTE~ THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
COMPLETION DATE ANTICIPATED
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL iNSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TANK SIZe /~ TYPe ~t~/ SEEPAGE AREA SIZE ~~/~ TYPE ~-/~p
MINIMUM DISTANCES, REQUIREMENTS
FOUNDATION TO SEPTIC TANK
FOUNUATION TO SEEPAGE PIT , DRAIN FIELD
SEPTIC TANK TO SEEPAGE PIT WALL '~/
SEPTIC TANK
TO NEAREST LOT LINE.
WELL 'TO SEPTIC TANK
DRAIN FIELD--_
SEEPAGE PiT ~ ~
ALSO CONSIDER AREA WELLS.
WATER MAIN TO SEPTIC TANK SEEPAGE PIT
DRAIN FIELD
/oo'
SEPTIC TANK, SEEPAGE PIT DRAIN FIELD
TO RIVER, LAKE, STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OP'
EXCAVATION S FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
DIAGRAM OF SYSTEM
GRAVEL BACKFILL
CONFORM TO BOROUGH ~LATIONS REGARDING INSTALLATION.
LICENSED DESIGNER
THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ~RDINANCE NO. 28-68 AND THAT THE ABOVE
CERTIFY
DESCRIBED YSTEM IS IN ACCORDANCE WITH SAID CODE. /~d./~,.~ ~/~.),~ ~,~,j~
Performed
Legal
This
DEPARi,.,c.T OF E~iVIROii~iE~T.~L GUAI.)i. CASE #
3500 TUDOR ROAD I~ECE~
ANCHORAGE, ALASKA 99502
JUL
Fo r_.J. POlyetko (owner - Harold Abrams) Date P e r fo rm~~
Description: Lot I Block 3 Subdivision Fire Lake
Form Reports Soils Log ~ ..... V~'rcol~'tibn Test
De
2--
4~
8---
10--
i2--,
14.~/ ·
)th
t
Soil Characteristics
Tan clayey'silt
Gray gravelly sand
with gravel and
cobbles from 6.5
to 7.5'
ML
SW
W~s Ground Water Encountered?.,No
If ,Yes, At What Depth?
Reading
Date
Gross Time
Net Tima
Depth to H20
Proposed Insta~ Seepage Pit x~ Drain
Depth Of Inlet p~'h TolBottom Of
COMMENTS:~t. ofdraina~D/bedroom.
Net Dro
Field
Pit Or Trench
N
· Y:
ALASKA MINERAL & MATERIALS LAB,' INC. Date :~Juiy j, lv/;~