HomeMy WebLinkAboutFAIRMOUNT LT 18
Se,, 10 20 04,50ri Vichorpga 'Nall YmPum.pSer 90724'x0742 p.1
. ... ....
75
n
"i -;r+
0 -5- r r cgr c r,
47,
0 x 19,6 6 5
Mark Beq,`ch
Archorcq�z, AV 9950-,
r
111ayor17
Pump Installation Log
Well Drilling Permit Numbet-:
SIV-- Date of Issue:
Parcel Identifficativn Yumber:
Leg21 Description
Property Owner Name Addmis:
Fo--(, r m Octet,
Pump Installation Date: CI '
,,18, /,Z6
Pufrip futake Depth Below Tot) of'kArelf Camng: Cejo feet
Painp Manufacrarer's Name: 10-12e.
- I
Pump Model: 64N S�V(
Pump Size hp
ftless Adapter SuriA Depth; feet
Phle-:S Adapter Installer-
WC11 Disinfected Upon Cout,pletiozi? "d �Yes i ! Nu
Method ol'Disinfution
Comments -
Pump Installer Name: Vvejj & Pump Service, L......
31 10 East 76th Avenue
Anchcrage, AK 99518
Phone: 907-21113.0740
F -,v! 907-243-0742.
ktteution: The pump installer sna!! picvidc a primp installadon log lo -,hL DSD wi�.-'tin. -30 :.,avS ofpu-m., instai'atio-n.
GAAB-HO- I
/,,- 2.
~,P""tER ANCHORAGE AREA BORG"
HEALTH DEPARTMENT ; Y -///
327 ~A~'LE ST. ANCHORAGE, ALASKA 99501 27~2511
NAME
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCATION
LEGAL DESCRIPTION
SEPTIC TANK:
DISTANCE FROM WELL
LIQUID CAPACITY_
GALLONS.
MAIERIAL (~"~ ~J'~"'/~''' NUMBER OF
COMPARTMENTS
INSIDE LENGTH ! INSIDE WIDTH '~' /
LIQUID
DEPTH ~"~'
SEEPAGE SYSTEM: SEEPAGE Pit:
NUMBER OF FITS ..... / OUTSIDE DIAMETER.
LINING MATERIAL__
NEAREST LOT LINE
o, W,DT, /5'"'"
DISTANCE FROM WELL /.~'~ O '/
TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA)
,LENGTH // ,
, DEPTH
, BUILDING FOUNDATION
so. ET.
TILE DRAIN FIELD:
DISTANCE FROM WELl
NUMBER OF LINES
ABSORPTION AREA
FOUNDATION.
DISTANCE BETWEEN LINES
SQ. FT. LENGTH OF EACH LINE
DEPTH: TOP OF TILE TO FINISH GRADE
TYPE DEPTH
NEAREST SEPTIC
LOT LINE , SEWER LINE , TANK
, NEAREST LOT LINE
'fRENCH WIDTH
TOTAL LENGTH
OF LINES
IN. TOTAL EFFECTIVE
DEPTH OF FILTER MATERIAL BENEATH TILE
IN. ABOVE TILE
WATER
SAMPLE
DISTANCE FROM
, BUILDING FOUNDATION
SEEPAGE
, SYSTEM , CESSPOOL
DIAGRAM OF SYSTEM
, NEAREST
OTHER
, SOURCES
DATE
APPROVED
HEALTH AUTHORITY
GAAB-HD-2
GREATEI
327 Eagle St.
,_NCHORAGE AREA
HEALTH DEPARTMENT
Anchorage, Alaska 99501
ROUGH
27%2511
Case N o.
SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT
APPLICATION TO INSTALL: SEPTIC TANK
TO SERVE THE FOLLOWING FACILITY
FINANCED THROUGH
PERCOLATION TEST RESULTS
~ MAILING ADD R ESS~,
NAME OF APPLICANT ~ · /
RESIDENCE ADDRESS--7/'~,'9 Z-~) /;'2' ';~:.~' LOCATION OF INSTALLATION
~ / LEGAL DESCRIPTION ~7~::./,~
~ , SEEPAGE PIT ~/ ,DRAIN FIELD
TO BE INSTALLED BY~
ANTICIPATED DATE OF COITION
PHONE NO.
,OTHER
BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT
THIS IS TO SERVE AS
AS DESCRIBED BELOW.
. SEPTIC TANK SIZE.
DISTANCES:
, PERMIT TO INSTALL A
SIZE OF UNIT TO BE SERVED
TYPE SEEPAGE AREA
DIAGRAM OF SYSTEM
TYPE
Health Authority
I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the
above described system is in accordance with said code.
DATE APPLICANTS SIGNATU RE
DAT~ RECEIVED
INSPECTION APPOINTMENTS
TIME TIME TIME
DATE DATE ~ / DATE
,NSPECTO ,NSPECTO ,NSPECT .
!
MUNICIPALITY OF ANCHORAGE ~UNIClPALI~ OF ANCHORAGE
825 L Street - Anchorage, Alaska 99501 "
ENVIRONMENTALSANITATION DIVISION JUN 1 9 1980
Telephone 264-4720
DIRECTIONS: Complete all parts on page 1. Incomplete requ~ will not be p~oce.ed, Please allow ten {10) days for processing.
1. PROPERTY OWNER I PHONE
MAILING A~DRESS
PROPERTY RESIDENT (If different from above) ~ PHONE
2. BUYER PHONE
MAILING ADDRESS
3. LENDING INSTITUTION ~ PHONE
I
MAILING ADDRESS
4. REALTOR/AGENT PHONE
MAI LING A~DR ESS
5. LEGAL DESCRIPTION
STREET LOCATION
6. TYPE OF RESIDENCE
~i~ SINGLE FAMILY
[] MULTIPLE FAMILY
NUMBER OF~BEDROOMS
[] One [] Four
[] Two [] Five
~ Three [] Six
[] Other
7, WATER SUPPLY
INDIVIDUAL*
[] COMMUNITY
[] PUBLIC UTILITY
8. SEWAGE DISPOSAL SYSTEM
INDIVIDUAL/ON-SITE**
[] PUBLIC UTILITY
* ATTACH WELL LOG. A well log is required for all wells drilled
since June 1975. For wells drilled prior to that date, give well
depth (attach log if available.)
YEAR ON-SITE SYSTEM WAS INSTALLED.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS
[] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2, WATER SUPPLY
[] INDIVIDUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[] I N DIVI DUAL/ON -SITE DATE INSTALLED
[]PUBLIC UTILITY
Connection Verified INSTALLER
[]Septic Tank or []Holding Tank
Size: / ~)(~)(~) If Tank is homemade SOILS RATING
give dimensions:
TYPE OF TANK MANUFACTURER
Absorption Area to nearest Lot Line
5, COMMENTS
[~//APPROV ED FOR -~ BEDROOMS
[] CONDITIONAL APPROVAL (letter must accompany certificate)
[] DISAPPROVED
DATE BY
72-010 (Rev. 6/79)
To/ ben Spurkland P.F..
8155 Cranberrv St.
Anchorage, Alaska 99502
Phone (907) 243-5302
Mrs Ginger Cassle
Busi Bee Realty
1401W 34th Ave
Anchorage, Akaska 99503
ADEQUACY
TEST
July 19,1980
MUNICiPALiTY OF ANCHORAGE
DEPT. OF I.F,\I.'?II &
ENVIRONMEN] AL D',LO I ECl'ION
,JUL g 8 1980
RECEIVED
Legal:
Residence:
Water:
Sewer:
Lot 18, Fairmount
3 Bedrooms, 2 Storey, Unfinished
On Site Well
From Municipal Records:
Constructed in 1969
Tank: Concrete, one compartment, 1OOO gal. capacity
Seepage Pit Concrete Rings
Absorption Area: 468 Sq.~%.
Date of Test: July 18, 1980
.~..' .
~e?;' ~ ..~..'~. taken:
~ · 0
Jl~;'.. ...;~';~ Absorption Rate
~2.45
ol.0o
4.45
Absorpt ion Rate:
Test Procedure: Tank Pumped on July 14, 1980
System inspected July 17.
Bottom of pit 7'-3" below ground
20 inches of water in crib
20 inches of water in tank.
Line between tank and crib 24 inches below ground. Cleanouts at
midp&int.
Crib was filled with water &n July 18 and the following readings
Depth In Crib Depth In Tank
24 24 "
50 24
70 24
¥
7O
54
41
29
24
O
REBAR
i
O
O
CD
02
0
0
LOT 17 �
Do
Do
�x
x
—x�
gg\� CREEK ONO
�
$�
ELECTRIC
O„ G LEJ TRANSFORMER
M
GRAVEL
RIVEWAY
WELL SEE
BUILDING
LOT 18
48,656 sq. ft.
SEPTIC
STANDPIPES
UTILITY
PEDESTALS
27.7'
T
O
O
0
O
m
O
O
m
w
rn
N
X�
Y
W
W
D_
U
Co
m
32.62'
S 84016'05" W gtio� M
�</��
�I/S 9
M
S 60001'41" W �o 7
9.37' 'co
Vol
LOT 28
NOTE
RABBIT CREEK MEANDER LINE REFLECTS
THE LOCATION OF THE ORDINARY HIGH
WATER ON JULY 5, 2026.
EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE
RECORDED SUBDIVISION PLAT (P-567) ARE NOT SHOWN HEREON.
THIS DOCUMENT DOES NOT CONSTITUTE A BOUNDARY SURVEYAND
IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT BOUNDARY
SURVEY MAY DISCLOSE.
UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE
USED FOR CONSTRUCTION OF FENCES, IMPROVEMENTS, OR FOR
ESTABLISHING PROPERTY BOUNDARIES.
bUILUIINO Ut I/HIL 1" = 1U'
0 25' 50,
AS -BUILT
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
FOLLOWING DESCRIBED PROPERTY:
LOT 18, FAIRMOUNT SUBDIVISION
ANCHORAGE RECORDING DISTRICT, ALASKAAND THAT
THE IMPROVEMENTSAS DEPICTED HEREON EXISTAS
SHOWN IN RELATION TO THE PROPERTY LINES.
DATED THIS 5th DAY OF JULY, 2026, ATANCHORAGE,
ALASKA.
FIXED HEIGHT, LLC C.O.A.122554
Land Surveying Services WWW.FIXEDHEIGHT.COM
600 W 41 st. Ave, Ste. C, Anchorage, AK 99503 907.290.8949
JOB # 26205 I NO CORNERS SET THIS DATE I SCALE 1" = 50'
MUNICIPALITY OF ANCHORAGE
Efwfmpqnfou!Tfswjdft!Efqbsunfou
Qipof;!!):18*454.8:15
Po.Tjuf!Xbufs!'!Xbtufxbufs!Tfdujpo
!!!!!Gby;!!):18*454.8::8
Dfsujgjdbuf!pg!Po.Tjuf!Tztufnt!Bqqspwbm
PTD37232:
603903138
Parcel ID 128!.222.21 Expiration Date:
Legal description GBJSNPVOU!MU!29
Site address
6751!SBCCJU!DSFFL!SE
Current property owner(s) !DVMLJO!UIPNBT!K
Y4
The On-site system(s) is/are approved for bedrooms
Conditional approval forbedrooms, with the following stipulations:
Comments or conditions:
Op!dpnnfout
Curtis Townsend
80803137
By:Original Certificate Date:
This Certificate of On-Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage,
Development Service Department (DSD) issues COSAs based upon representations provided by an
independent professional engineer. The Municipality of Anchorage is not responsible for errors or
omissions in the professional engineer's submittal.
ATTACHMENTS:
!!!!!!Y
COSA ChecklistWell Flow Advisory
Absorption Field AdvisoryNitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On-Site Water & Wastewater Section Fax: 907-343-7997
COSA Application_Apr2025.doc
Certificate of On-Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D.
Complete legal description
Location (site address)
Current property owner(s) Day phone
2. ON-SITE SYSTEMS SIZED FOR BEDROOMS
3. TYPE OF WATER SUPPLY: Private Well serving # dwelling units
Other Non-public well as regulated by MOA Water Storage
Community Well or Public
4. TYPE OF WASTEWATER DISPOSAL: Private Septic Private Septic serving 2 dwelling units
Holding Tank Community Septic or Public Sewer
5. SEPTIC TANK: Steel Plastic Concrete Fiberglass
Age ______ - See advisory if steel or fiberglass older than 20 years
6. ABSORPTION FIELD: AWWTS Bed Deep Trench Wide Trench Seepage Pit
Waiver request for: Distance:
Expedited review requested:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ Waiver Fee $
Date of Payment Date of Payment
COSA # Waiver #
COSA Checklist.docx
COSA Checklist
Legal Description: FAIRMOUNT LOT 18 Parcel ID: 017-111-10
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled UNKNOWN Total depth UNK ft
Cased to UNK ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 18 in.
Date of flow test for COSA 6/4/26
Static water level at beginning of test 18 ft.
Well production at time of test 0.58 gpm
Water storage tank volume None gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by Date 5/28/26
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank 59"
Date of pumping 5/29/26
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. DISPOSAL FIELD DATA
Which system tested (date installed) 6/25/1969
ALL standpipes present per record drawing
Total measured depth from grade 7.3 ft (max)
Measured depth to pipe invert from grade 2.6 ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective (ED).
If not, state depth into effective 4.7’
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced 2000 gallons 6/3/26 date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 6/4/26
Results Pass
Fluid depth prior to test 2 in
Water added 450 gal
New fluid depth 25 in
Elapsed time 1440 min
Final fluid depth 2 in
Absorption rate 450 gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 72 in (MOA 6’ ED)
Effective depth (ED) used 18 in (Final Fluid Depth + missing ED)
Effective depth remaining 54 in
Comments/Deficiencies: Approximate total measured depths from existing grade. Presoak of 2000 gal filled crib up to the
invert. After Presoak, the next day fluid levels were 2”. Per MOA doc Crib consists of two 3’ concrete rings. Measurable ED
is at 4.7’ the adequacy test of 7/17/1980 reflects these numbers as well.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Well on Lot to: (Please enter distances if less than required)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Disposal Field on Lot > 100’ Yes if No ft
Neighboring Disposal Fields > 100’
Yes if No ft
Sewer Line/Main > 100’ Yes if No ft
Sewer Manhole/Cleanout > 100’
Yes if No ft
Sewer Service/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required)
Tank to Foundation > 10’ Yes if No ft
Field to Foundation > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main/Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No *50+ ft
Wells on Adjacent Lots:
Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
*Per code at time of install & per discussions with Curtis Townsend, PE of the MOA.
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 06/30/2026
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
06/30/26