Loading...
HomeMy WebLinkAboutGLACIER VIEW HEIGHTS #4 BLK 2 LT 6ier View Heights #4 #050-501-40 Municipality of Anchorage On -Site Water and Wastewater Program < (907) 343-7904 Page 1 of 4 ON-SITE WASTEWATER INSPECTION REPORT Permit Number. OSP151128 PID Number: 050 -- ,0 1 - 14c) Dwelling: ❑ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑ Upgrade Name: Carl & Christine Lundgren ABSORPTION FIELD ❑Deep Trench FIM Shallow Trench ❑ Bed ❑Mound Address 22743 Eagle Glacier Loop, Eagle. River..., El Other Phone Number of Bedrooms Soil Rating Total depth from original grade 5 0.6 GPD/sF 3.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 1.0 Ft. Gravel depth beneath pipe 2.0 FL Subdivision Block Lot Glacier View Heights #4 2 6 Fill added above original grade 2.0 FL Gravel length 32 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES Tol Septic Absorptionj Holding Lift Station I Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 228.6 Added Ftz 1 added 10+ to exist Ft. Well 116.4 131.8 I 125.7 1 N/A 100-{- TANK ❑ Septic ® S.T.E.P. ❑ Holding Other g E3 Manufacturer Anchorage Tank Capacity 12000 Gal, i Surface Water 100+ 100+100+ I N/A Material Number of compartments Lot Line 65.0 37.7 75+ I N/ANA Steel 2 Foundation 8.0 30.5 19.8 N/A LIFT STATION Manufacturer Capacity I Curtain Drain i 50+ 50+ N/A i N/A Anchorage Tank/ Orenco 250 Gal. Remarks Combined total area is 125Qsf. Pump on level at 43 in. Pump off level at 40 in. High water alarm at 5 in. NZt. 1. ( i ti l I, Pump make and model P2005 Electrical Inspections performed by J ELECTRIC LLC Installer PIPE MATERIAL House to tank PVC Tank to drainfield PVC Alaska Divers & Underwater Salvage Drainfield PVC CO/MT V Inspector Pannone Engineering Services BENCHMARK (Assumed elevation) 100 ft Inspection 1�` 9/11 /15 1/25/16 Location and description 2^d 3"' .41h Bottom of trim at 'A' COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Q( tkj Conditional Approval: Date C0 iteven f$. *99 norae CE Lux Approved'�Utol Date 1,1 q/lg 11 Q1JJC000I I MZPUI t_tl- 1- 14.UUU WELL (E) / r A.�/� \ COLLAPSED 12508 SEPTIC TANK & \ G DECOMMISSIONED PER CODE x INSTALLED 2000g S.T.E.P. TANK (P)\ \ \ O 6 5BR SEE FIELD CONNECTION DETAIL \ w-HOUSE"w __._ -__ _ _DRAIN FIELD (E) T ADD 5'W x 32LF x 2.0'ED x 3.0'TD \\ AT\ 4. \ MT1 1 " LATERAL W/ 3/6" HOLES 36" O.C. WITH MONITOR TUBE AT EACH END " MH \ \-• �/ 108 e MT TH-PES 104 '� S \ Fp�o TH-1984 - LSEPTIC ARE'k(E) 100 RESERVE DRAIN FIELD (P) 26.25LF x 5'W x 2.0'ED x 3.0'TD - es - I \ \\ BASED ON CAT III � 92- 84. z- - WELL (E)\ DESIGN PARAMETERS DESIGN PARAMETERS UPGRADE SEPTIC SYSTEM RESERVE SEPTIC SYSTEM NO. BEDROOM: 5 (750 gpd) NO. BEDROOM: 5 (750 gpd) TANK SIZE: 2000g S.T.E.P. 'TANK SIZE: 2000g ADVANTEX TANK PERC RATE: 16-30 MPI WITH (2EA) AX20 PODS SOIL RATING -0.6 GPD/SF PERC RATE: 16-30 MPI AREA RQD: 1250 SF SOIL RATING: 4 GPD/SF SYS. TYPE: WIDE TRENCH 2.0'ED AREA RQD: 187.5 SF RF: 0.70 SYS. TYPE: WIDE TRENCH 2.0'ED MIN LENGTH: 175 LF RF: 0.70 MIN LENGTH: 26.25 LF USE: EXISTING 1 43L x 5.0'W x 2.0'ED x 3.5'TD USE: ADD 32 LFx5'Wx2.0' E.D., 3.0' TD 26.25LF x 5.0'W x 2.0'ED x 3.5'TD TOTAL AREA: 1250 SF TOTAL AREA: 187.5 SF 0 NOTES: A B FC 17.3 14.10 T1 14.5 23.6 T2 18.3 . 35.0 MH 19.8 37.2 MT1 33.0 55.4 MT2 60.0 73.40 NOTES: PANNONE ENCS SVC LLC P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-821149 *� 49 TMy*� . .. ... . .... ... .. .... �� SteveCER8149 no��' RECORD DRAWING GLACIER VIEW HEIGHTS #4, BLOCK 2, LOT 6 CARL & CHRISTINE LUNDGREN 22743EAGLE ARI VERGLACIER AK 1995770P �,tl>1i�`�/�?0�SS10NP��� PLAN Date 01/26/16 Scale 1"=50' P.I.D. NO -050-501-40 PERMIT NO. OSP151128 Sheet 2OF5 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS AND ATTACHED SPECIAL PROVISIONS. ASB 2. SCOPE OF WORK: INSTALL NEW 2000g S.T.E.P. TANK AND VERIFY SOIL ABSORPTION SYSTEM. IF SYSTEM IS IN FAILURE PERFORM TEST HOLE FOR FIELD UPGRADE, IF FIELD IS OPERATING ADEQUATELY ADD FLOW SPLITTER AND ADDITIONAL ABSORPTION AREA. ASB 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 7.5 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 7.55 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. ASB 4. THE CONTRACTOR PROVIDED DATA (UPON WHICH THIS RECORD DRAWING IS BASED) APPEARS TO REPRESENT THE PROJECT AS CONSTRUCTED. THIS DATA 1N CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE ENGINEER (OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN DEFECTS BY THE CONTRACTOR. ASB LFILTER BRIC TOPSOILERF PIPE `t! 3 16" HOLES DRILLED 36" O.C. AND VEGATATE / /OCK 6" ABOVE PIPE INV TH-1 •5 b4P0 EL, 104.0 —1.0 OR OL v 0f N 0.5 x.: -1 GM 50— .1 1. — .,1 t. —9.5 94.5 SECTION N �w R.I. wm DRY 9/18/15 FILTER FABRIC 12 p 1.0" m PERF PIPE 4'd/ x 6" TOPSOIL z Z 3/16" HOLES DRILLED 36" O.C. t= AND VEGATATE z �= ~_ DRAIN ROCK 6" ABOVE PIPE INV g r 0 0 O C) 3 SRX 3'7 a"4 EL.t04.0 EL. 100-0 r a....1 ji < .101. 2000g S.T.E.P.F EL.95.4 TANK (P) ILE NOTES: �"t ' LLC�"a� Dote RECORD DRAWING �l �F AC q>� 01/26/16 P.O. BOX 100217 ANCHORAGE, AK 99510 s� !F- Scale PHONE (907) 272-8218 FAX (907) 272-8211 NTS 49 P.I.D. NO GLACIER VIEW HEIGHTS #4, BLOCK 2, LOT 6 050-501-40 CARL & CHRISTINE LUNDGREN Sievers R Ponnone PERMIT NO. CE 8149 05P151128 22743 EAGLE GLACIER LOOP + cs•. SECTION/PROFILE EAGLE RIVER, AK 99577PROfESS10NP�Sheet � � • Q'�� 3OF5 SPECIAL PROVISIONS TO SPECIFICATIONS 1 . ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS AND ATTACHED SPECIAL PROVISIONS. 2. SCOPE OF WORK: INSTALL NEW 2000g S.T.E.P. TANK AND VERIFY SOIL ABSORPTION SYSTEM. IF SYSTEM IS IN FAILURE PERFORM TEST HOLE FOR FIELD UPGRADE, IF FIELD IS OPERATING ADEQUATELY ADD FLOW SPLITTER AND ADDITIONAL ABSORPTION AREA. 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 7.5 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 7.55 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 4. THE CONTRACTOR PROVIDED DATA (UPON WHICH THIS RECORD DRAWING IS BASED) APPEARS TO REPRESENT THE -PROJECT AS -CONSTRUCTED THIS -DATA IN -CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE ENGINEER (OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN DEFECTS BY THE CONTRACTOR. 1" PIPE TO PF 1.5" PIPE FROM LIFT STATION 1.25" PIPE LEGEND W WATER LINE/ WELL RADIUS SS NEW SEPTIC ABBREVIATIONS 7 TH TEST HOLE FIELD CONNECTION DETAIL FC FOUNDATION CLEAN OUT T# TANK CLEAN OUT NO. C# CLEAN OUT NO. M# MONITOR TUBE NO. R.I. RIGID INSULATION DCO DOUBLE CLEAN OUT DV DIVERTER VALVE FS FLOW SPLITTER NOTES: PANNONE ENG SVC, LLC P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 -�`� �� ���F A�q�lj �,`Q-. ' S,� j C-) y �O *: * F, Date 01/26/16 RECORD DRAWING scale NTS GLACIER VIEW HEIGHTS #4, BLOCK 2, LOT 6 _aolOao CARL & CHRISTINE LUNDGREN 22743 EAGLE GLACIER LOOP EAGLE RIVER, AK 99577 Steven R. I'annorie / c . CE 8149 +� sr ORFSQOA- . PERMIT NO. 05P15t 128 DESIGN DETAILS Sheet 4 OF 5 1 2 3 4 5 6 7 8 9 TH-PES ORGANICS/ ORGANIC SILTS LOOSE SILTY SAND AND GRAVEL BOH DATE PERFORMED:09/11/15 SOILS LOG - PERCOLATION TEST SLOPE TH WAS GROUND WATEF ENCOUNTERED? N IF YES, AT WHAT DEPTH? 0' DEPTH TO WATER AF MONITORING? DRY DATE: 09/18/ READING DATE CLOCK TIME NET TIME WATER LEVEL READING NET DROP 1 11SEP15 1055 --- 4.96 --- 2 1105 10 MIN 9.01 4.05 2.46 3 1105 --- 4.94 --- 4 1115 10 MIN 8.07 3.13 3.19 5 1115 -- 4.95 --- 6 1125 10 MIN 8.02 3.07 3.25 PEROLATION RATE 3.25 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 2 FT AND 3 FT COMMENTS: Test hole excavated by SPINELL HOMES. Prec hole was presoaked. Test run for at least one hour. Last 3 readings reported PERFORMED BY: Dan Moran. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. NOTES: PAMONE ENG SVC, LLCq�\alt cite 16 RECORD DRAWING P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 W.-.4 TH * Scale +�� NTS ....... ... P.I.D. NO GLACIER VIEW HEIGHTS #4, BLOCK 2, LOT 6 .... .. / 050-071-17 Steven R. Pannone PERMIT NO. CARL & CHRISTINE LUNDGREN �,'. CE 8149 Fri/ OSP151097 22743 EAGLE GLACIER LOOP �� ' _ SOILS LOG EAGLE RIVER, AK 99577 �lli��ossl=i�?� Sheet 5e0F 5 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151128 Tax Code Number: 05050140000 Work Type: Septic Upgrade Permit Effective Dates: August 25, 2015 to August 24, 2016 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: GLACIER VIEW HEIGHTS #4 Site Legal Address: GLACIER VIEW HEIGHTS #4 BLK 2 LT 6 G:0159 Owner/Address: LUNDGREN CARL E JR & CHRISTINE M 22743 EAGLE GLACIER LP EAGLE RIVER AK 995770000 Site Mailing Address: 22743 EAGLE GLACIER LOOP, Eagle River This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy All construction must be in accordance with: Lot Size in Sq Ft: 43560 Total Bedrooms: 5 N Private Well N Water Storage 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: 1. The testhole location does not match the location shown on the 1984 soils log. For the northernmost trench, the Engineer needs to do an additional test hole, minimum 6' deeper than the proposed field, prior to the construction of the septic field. Construction may proceed at your own risk before the 7 day water monitoring is complete. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. 2. A squirt test is to be done to show adequate distribution between the two sections of the field prior to backfilling. The test is to be observed by MOA staff. Received Issued By: Qslaais Date: g Z✓r /5 MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division QD Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 050-501-40 SUS "TTA MAY 15 2015 Gretchen Stupe, - Property owner(s) Carl & Christine Lundgren - Day phone None Available Mailing address 22743 Eagle Glacier Loop, Eagle River, AK 99577 Site address 22743 Eagle Glacier Loop Legal description (Sub'd., Block & Lot) Glacier View Heights #4, Block 2, Lot 6 Legal description (Township, Range & Section) Lot Size 43,560 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (E all that apply) Absorption Field �( Initial F-1 Single Family (SF) (w/wo ADU) Septic Tank Upgrade ❑x Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: 354 Distance: Zti I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner. or authorized agent) Permit/Rush Fees: 02/5 Date of Payment: Receipt Number: Permit No. QSYlJ�/�e�g IP -3.5q 0601,36 7//30/s Permit App__ :-:L�c, Waiver Fees: Date of Payment: Receipt Number: Waiver No. _ Pannone Engineering Services Lac Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve(d)Daneneak.com August 14, 2015 Subject: Glacier View Heights #4, Block 2, Lot 6 Septic System Permit Request Design Narrative This is a design narrative for a permit to install a septic system to be issued for this property. The proposed systems will serve an existing five (5) bedroom house. The existing system was designed and installed for a four (4) bedroom house and will be expanded to accommodate five. The existing field is currently dry and operating adequately. Currently the lot is developed. This lot is served by a private well. The surrounding developed lots are served by private wells. There are no wells within 100' of the proposed septic system. 1. Soils. One test hole was performed in the vicinity of this system by Lee Reed in May of 1984, and groundwater was monitored for at least seven days. Ground water was observed at a depth of 7.5' below thesurfacein the test holemonitor tube in May of 1984. Bedrock was not encountered in the test hole. Based on the results of the percolation tests and overall soils appearance; an application rate of 0.6 gallons/day/square feet was used for a conventional wastewater system in the area of these test holes. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The existing topography slopes from the northeast to the southwest at approximately 16% in the area of the septic system. There are no steep slopes within 50' of the proposed drain field. The proposed drain field will maintain 50' separation all steep slopes. S. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification t15at the review is complete and that there are no further comments is received from MoA On -Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 m "?o v \ v W-41- (E) _ • _ A \ A \ LQ Zt + COLLAPSING 12509 SEPTIC TANK (E) "WELL (E) DECOMMISSION PER CODE \ INSTALL 20008 S.T.E.P. TANK (P) 17.6 \ /� SEE FIELD CONNECTION DETAIL SBR iy W- HOUSE \ DRAIN FIELD (E) \ (E). \ ADD 5'W x 32LF x 2.0"ED x 3.0'TD fy \ 34 j 5.7 1" LATERAL W/ 3/6" HOLES 36" O.C. WITH MONITOR TUBE AT EACH END ol - 4b FR \ \ TH-1984 ! LSEPTIC AREA,(E) 10.0 \ v A 100.0 \ RESERVE DRAIN FIELD (P) \/2— \ � � �• 26.25LF x 5'W x 0'ED x 3.0'TD _ BASED ON CAT III I A � WELL (E) NOTES: _���� \\ Date -- CHANGE ORDER Ip�ONgp Oj ONO2E1{7 ENG ORA�SGEV, CK 99JL0 c�°F... g-d l� 7/28/2015 PHONE (907) 272-8218 FAX (907) 272-8211%g�p —01 Scale �.... .. .. .. ... I 49 P.I.D. NO GLACIER VIEW HEIGHTS #4, BLOCK 2, LOT ........... 050-501-40 CARL & CHRISTINE LUNDGREN S'te'ven R.'. on'none' j PERMIT No. 22743 EAGLE GLACIER LOOP ��'Pc E 81 ag, \��/ SOSPI hee61128 PLAN EAGLE RIVER, AK 99577 1klla, p sheet \\ "�� 1 OF 2 SPECIAL PROVISIONS TO SPECIFICATIONS 1, ALL CONSTRUCTION SHALL. BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS AND ATTACHED SPECIAL PROVISIONS. 2. SCOPE OF WORK: INSTALL NEW 20009 S.T.E.P. TANK AND VERIFY SOIL ABSORPTION SYSTEM. IF SYSTEM IS IN FAILURE PERFORM TEST HOLE FOR FIELD UPGRADE, IF FIELD IS OPERATING ADEQUATELY ADD FLOW SPLITTER AND ADDITIONAL ABSORPTION AREA. 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 7.5 FEET BELOW EXISTING GRADE AS EVIDENCED BY .THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 7.55 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 1" PIPE TO PROPOSED LEG OF FIELD 32' LEG (P) 1.5" PIPE FROM LIFT STATION— II F — 1.25" PIPE TO EXISTING FIELD I I I I I I I 1 .25 x 4" REDUCER I )11 I EXISTING FIELD L I I FIELD CONNECTION DETAIL DESIGN PARAMETERS UPGRADE SEPTIC SYSTEM NO. BEDROOM:5 (750 gpd) TANK SIZE: 20008 S.T.E.P. PERC RATE: 16-30 MPI SOIL RATING: 0.6 GPD/SF AREA ROD. 1250 SF SYS. TYPE: WIDE TRENCH 2.0'ED RF: 0.70 MIN LENGTH: 175 LF DESIGN PARAMETERS RESERVE SEPTIC SYSTEM NO. BEDROOM: 5 (750 gpd) TANK SIZE: 20009 ADVANTEX TANK WITH (2EA) AX20 PODS PERC RATE: 16-30 MPI SOIL RATING: 4 GPD/SF AREA ROD: 187.5 SF SYS. TYPE: WIDE TRENCH 2.0'ED RF: 0.70 MIN LENGTH: 26.25 LF USE: EXISTING 143LF x 5.0'W x 2.0'ED x 3.5'TD USE: ADD 32 LFx5'Wx2.0' E.D., 3.0' TO 26.25LF x 5.0'W x 2.0'ED x 3.5'TD TOTAL AREA: 1250 SF TOTAL AREA: 187.5 SF NOTES: PANNONE ENG SVC, LLC CHANGE ORDER P,O, BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 GLACIER VIEW HEIGHTS #4, BLOCK 2, LOT 6 - CARL & CHRISTINE LUNDGREN 22743 EAGLE GLACIER LOOP DESIGN DETAILS EAGLE RIVER, AN 99577 LEGEND W WATER -LINE/ WELL RADIUS — SS — NEW SEPTIC ABBREVIATIONS CU COPPER DIP DUCTILE IRON PIPE TH TEST HOLE FC FOUNDATION CLEAN OUT T# TANK CLEAN OUT NO. C# CLEAN OUT NO. M#. MONITOR TUBE NO. R.I. RIGID INSULATION DCO DOUBLE CLEAN OUT DV DIVERTER VALVE FS - FLOW SPLITTER BFG BELOW FINISH GRADE OG ORIGINAL GRADE FG FINISH GRADE - TS&V TOPSOIL AND VEGETATE NIC NOT IN CONTRACT OF A/ ---I )ll 8/14/2015 Scale NTS *: Fi 49 T 6 P.LD. NO ........� Steven R. Pannone / 050-501-40 IPS CE 8149 �� PERMIT N0. OSPI51128 Sheet (�1'1�F��DIONpV�` ROFESFESS ' 2 OF 2 Glacier View Heights SRP 150911 NOMINAL PIPE SIZE (in) PVC Plastic (in) Pipe Length (ft) Pipe Length (miles) Kinematic viscosity (ft%) Smoothness (a) (in) Flow in gpm Volumetric Flow Rate (Q)= Velocity (v) Reynolds number (RE) Ratio (e1D) f (from Moody diagram) Headless (4) Headless (h) Number of 90 Bends Long Sweep Elbe Coefficient, K Bends Headloss (q) - Bends Headless (YI) Total Headless (q) Total Headless (hr) Check: Hazen Williams Coefficient, On Hydraulic Radius Head Loss (4) Headless (h) Total Headless (h) Total Headless (hf) Static Suction Head (hR>1 Static Suction Head (t5!s>1 Static Discharge Head (111 Static Discharge Head (11t,$) Data for Pump Head Loss calculations ENTERJDATA'INBLUE' CELLS 01 IN - gpm Suction Discharge .1.25 50 `' 37 , 1.24 ---0-.013 - - 17 -=U311 - 0.003219E 'ff= _`-0•= _0 �;� _- 1.66E-05- 1.66E-05 1.66E-05 1.66E-05 -1.66€ 05 - - 0 0 #DIV/Or gpm 6 89 _55 50 `' 37 , (ft3/s) ---0-.013 -0x98 -_=0.123 -=U311 4—"0:082 R4.. (fus) 9.59- :=;='#DIV/0r - -#DIV/0! :;#DIV10Y #DylOr (ft) (psi) 2 =4.90€+03 -::_ #DIV/01 .'#DIV/OL '-#DIV/01 - #DIY/O{- --::-0.0:- -•-0.00000 #DIV/01 `IDIV/OY #DIVIO17#DIV/Or 71Ctlf . r #DIV10l =.#DIV/Dr -#DIVIOt- -,12 ._ 0.0320 0.0170 .- 0.0170 1 0.0170 1 0.0170 - (psi) ,.-: 0.1 ::#DIV/OL #DIV/Or I --#DIV/O! #DIV10r (ft) r 0.2'_ -:e-_#DIV/01 --#DIVIOr :-#DIVfOt --#DIV/Or _ (psi) '•0:1:.- :'#DIV/OF <'. 0.1 - `-.-#D#DIN/0! ---- --#DIV/01 _ =#DIVJOE -:#ONlOr (ft) (psi) 2 2 2 0.6 0.6 0.6 - - --::-0.0:- -- #DIVrot _.- :-#DIV/O! - ,-#DIV/0r-#DIVIOr 7ED- _ '-0.0. --:#DN/O(- s r #DIV10l =.#DIV/Dr -#DIVIOt- -,12 ._ (ft) - -0.3 - #DN/0! #D1VI01 r:#DIVIOt -#DIV/Or Dk17. ._. (psi)-...0.1_-#DIVI01 -- -#D!M-#DIV101 -=#DISI/OL �fQL (ft) 1 4.0 (psi) -,-.1.7 - - (psi) NPSHA NPSHA NPSHR NPSHR Total Headless Total Headloss 135 135 135 150 - (ft) 0.03 -"0.00 =r- -.::-0.00 (ft) _: 0.2: - -- --#DIV/01 -<#DIV/O! =-#DIV/OL (psi) ,.-: 0.1 ::#DIV/OL #DIV/Or I --#DIV/O! #DIV10r (ft) - =-0.2 -=V101. - --#DIV/Or _ _ 11DIVI01 (psi) <'. 0.1 - `-.-#D#DIN/0! ---- --#DIV/01 _ =#DIVJOE -:#ONlOr ,#D11- - (ft) 1 4.0 (psi) -,-.1.7 - - (psi) NPSHA NPSHA NPSHR NPSHR Total Headless Total Headloss (ft) (psi) (ft) (psi) (ft) (psi) 3.5 ---1:5-:- 4.3 -=-4:6.- �' external piping is copper Temperature @ 40 F raze=62.4 Ib/ft' Volumetric Flow Rate (Q): Reynolds number (RE): f: Headless (h): Headless, Bends (11): g=32.2 ft?/s Q=gpm/6017.48 - RE=DvN from Moody diagram h,=f`UD`V12g hr -K` 129 Pump Selection for a Pressurized System -Single Family Residence Project Parameters Discharge Assembly Size 1.00 inches Transport Length 25 feel Transport Pipe Class 40 gpm Transport Line Size 1.00 inches Distributing Valve Modd None Transport Velocity Max Elevation Lift 6 feet Manifold Length 0 feet Manifold Pipe Class 40 Manifold Pipe Size 1.00 inches Numberof Laterals per Cel I 1 Lateral Length 32 feet Lateral Pipe Class 40 Lateral Pipe Size 1.00 inches Orifice Size 3116 inches Office Spacing 3 feet Residual Head 4 feet Flow Meter - None inches 'Add-on' Friction Losses 5 feet Calculations Minimum Flow Rate per Office 9.87 gpm _ Numberof Orifices per Zone 11 feet Total Flow Rate per Zone 9.8 gpm Numberof Laterals per Zone - 1 feet Row Differential lst(Last Office 6.3 0.7 Transport Velocity 3.6 fps Frictional Head Losses Lossthrough Discharge 3.1 feet Loss in Transport 1.3 feet Loss through Valve 0.0 feet Loss in Manifold 0.0 feet Loss in Laterals - 0.7 feet Loss through Flowmeter 0.0 feet 'Addon' Friction Losses 5.0 feet Pipe Volumes Vol of Transport Line 1.1 gals Vol of Manifold 0.0 gals Vol of Laterals per Zone 1.4 gals Total Volume 2.6 gals Minimum Pump Requirements Design Flow Rate 9.8 gpm Total Dynamic Head 20.1 feet M Ore co Systema° lwnmowad f'rgdre l&n rAe lta./dDee leum�mm' a F Pu Net Discharge (gpm) System Curve: Pump Cum:,— Pump Optimal Rahge� Operating -Point Design Pointo Pump Selection for a Pressurized System - single Family Residence Project Parameters Discharge Assembly Size 1.25 inches Transport Length 10 feet Transport Pipe Class 40 feet Transport Line Size 1.25 inches Distributing Va the Model None feet Max Elevation Lift 0 feet Manifold Length 0 feet Manifold Pipe Class 40 Manifold Pipe Size 1.00 inches Number of Laterals per Cell 1 Lateral Length 32 feet Lateral Pipe Class 40 Lateral Pipe Size 1.00 inches Orifice Size 1/8 inches Orifice Spacing 2 feet Residual Head 4 feet Flow Meter None inches 'Add-on' Friction Losses 0 feel Calculations Minimum Flow Rate per Onfics 0.39 gpm Numberof Orifices per Zone 17 Total Flow Rate per Zone 6.6 gpm Number of Laterals per Zone 1 Flow Differential lsULast Orifice 3.4 TAnsport Velocity 1.4 - fps Frictional Head Losses Lossthrough Discharge 0.3 feet Loss in Transport 0.1 feet Lossthrough Valve 0.0 feet Loss in Manifold 0.0 feet Loss in Laterals 0.3 feet Lossthrough Rowmeter 0.0 feet 'Add-on'Fdcdon Losses 0.0 feet Pipe Volumes Vol of Transport Line 0.8 gals Vol of Manifold 0.0 gals Vol of Laterals per Zone 1.4 gals Total Volume 2.2 gals Minimum Pump Requirements Design Flow Rate 6.6 gpm Total Dynamic Head 4.7 feet. cis Oreeeo syat e Incarrmra Cbang�gok Wgrbe World Lb Wmmxxr" 2 12 Pu Net Discharge {gpm) System Curve: Pump Curve: Pump Optimal Ranger Operating Point Design Pointo / MUNICIPALITY OF ANCHOHAL~E DEPARTr IT OF HEALTH & ENVIRONMENTAL PieD' TION ..VIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska ~501 Telephone ~720 ' ON~ITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECT'ION REPORT MAILING ADDRESS LEGAL DESCRIPTION ~ Liq, capacity in ~llons I Inside length Width Liquid depth /~ IF HOME.DE: 6OM DISTANCE TO: Well Dwelling PERMIT NO~ -J Z OZ~ ~ 3: -- ~ Manufacturer Material Liquid ~pacity in gallons Q Well Near~t lot line ~ DISTANCE TO: ~7~ ~ lq/ 37/ .~ ~ ~ No. of lines Length of ea~ line ~ Total length of Jines T~nch ~dth ~ Distance ~t~en lines ~ Top of ti,e to finish ~/~' ' .teria, ~neath the . Total eff~tive absorption area Length Width ~th PERMIT ~.~  Ty~ of crib Crib diameter ~ib depth Total ~ti~ absorption area ~ Well Building foun~tion N~r~t lot line DISTANC~ TO: .~ CI.&~__~ ,~ Depth Driller Di~tan~ to lot '~e PERMI~ Building foundation ~r line ~pfic tank Absorption area(s) OTHER ~,PE MATERIALS SOIL TEST RATING ~NSTALLER ~EMARKS , 72-013 (Rev. 3/781 PERMIT DEPTH TC PiF~. ~OTTOF (':T.) GRAVEL DFpTH (FT.) TOTAL OLPIH (FT.) GfiAVEL WiNTh (FT.) GRAVxL LENGTH (FT.) GRAYEL ~OLUf,'L (CU.VO].) SOZL RATikG -'-(1, '~ lZ; 0 *¢, 1,,750.0 ~ !.,259.0 ** =* ~RAVEL LENGTh > 75 F~, RE'~bI~'ES PULTIUL~ PUNS i C~RTIFY THAI: " 1, I AM F.a)I!Li'~ ',~fH TPE RZqUiHE~',E~TS FOf~ Ch-Sl~'r S':bE~S Ak) W~LLS .;~S SET . _. ¢OFTh EY T~.{ -IUS~ICIP?~LI'FY CF NNCHO~&EC (FCA) ,~N) '"H;: ST&X'~ OF ALASKA, ~. I WTM * GUL~T']C ], i NZLL. A~Ht~c TO ALL MCA AND ST~T~ 3F AL~SKq N~.aU~iN'~NT~ FOE SEkEfiAEE SY~'F=~- CH TH;S CR AhY AOJACF'~T C" ~'~;;A~Y LOT, 4. I bNOEGSIAND .THA1 T'JIS P~RMZT ZS VALi') FC? ~, '~AX~IU''~ OF ~F A LIFT ,; AIiCN .'S I,~,:ST~L.L~'P. IN AN /~:~ COVE'~ .... ~ ' WiLL NO1 BF AFPFOV=D ~[T~ICUT ~?,1 CL';:CT.q~C:~. ZXS-)F-'CTTC','~ ~['~C?~; q~,;b ('¢) THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L, Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SOILS LOG PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 2 3 4 7 8 10 12 15- ~7 ~8 SITE PLAN I+ WAS GROUND WATER S ENCOUNTERED? 7,(~ ~ L 0 / P IF YES, AT WHAT ~ E / DEPTH? />, :. Gross Net Depth to Net Reading Date Time Time Water Drop .... l ¢/¢m ~.?~.:..,iiD . :-.' b',//I 0 ~..,.?--,:?,,. I I .:~ ~: ~_.: .... ,7o %..: PERCOLATION RATE I~//,~ (mi TEST RUN BETWEEN . FT AND ,,,=.--~-,,~-,.-~ FT 72-008 (6~79) MUNICIPALITY OF ANCHORAG~ Df!PT. OF HE,z',I.1H & ENVIRON,MEN fAL PRO I EC FION LOCATION OF WELL AUG 2 !984. Ri::C, EIVED Anoh i~DISTA"C~ Street Addrese end Area of Well Location WELL Material Type Topsoil ---~rave!, si~$~, soi~-- Gr~vel, si!~, ! wa~er Gravel, clay silk Gravel, sand, sil't, water Section No, A"O 0,R~CT,O. "RO~ .O^O ,.TERSECT,O.S Well # 1: WATER WELL RECORD STATE Of ALASKA DEPARTMENT OF NATURAL RESOURES Division of Geological I~ Geophysical Surveys OrllHng Permit No, A.D.L; No. 35 -'-'F,'TO--' 140 148 M=rldlon ~. OWNER or WELL: M~' Ray Pel!etier shasta .co'ns~ruct ton Add~e,,: :67 i iQ'ii!;E ;,. ~:1 6t~ i' '. ' ~ d'hb:z'age'; Ak. 99504 ,,.("""" ,' 4_ ?. UB~:~omelfle : El Public 'Aapply [] Indue/fy [] .,rlw.en [] n.~e*o. []Co~,n,e~[col [] T.e,w.,, [] O,h.,: __ Diameter:. Longlh: fl, end Gravel pock ft. g. FINISH OF WELL: Type: Slot/Mash Size Sol bolween Baokfllllng STATIC WATER LEVEL'~_ 55 fl. 5 ~.0 / Dote [] Above or ~ Below land surface Equipment us.d: II,PUMPING LEVEL below land surface and YIELD __ft. after hfs, pumping g.p,m. ft. after ~hrs. pumping ~l.p.m. I:).GROUTING Well {3routed: ~ Yes [] No Material: []Neat Cemenl [] Other: I~, PUMP= (if available) HP Length of Drop Pipe ft. capacity ~4'REMARK~Sroduotion of 3 GPM WATER WELL CONTRACTOR'S CERTIFICATION: This wall Wal drilled ~nde~"my lurlsdlollon and lhls raper1 I$ Iruo to the besl of my knowledge end belief; Magnuson':~Drilllng AA 5385 .0. ~ox.v'./UpU~ Eagle River, ~. Addre~: 1984 POuQ,~ ~ 6-650 ANGIiORAGE, ALA',}KA 99502 0650 (907') 2{;,i-411 I DEPARTMEN'I'OF HEALTItAND ENVIRONMEN]AL PI~OTECTION Permit ~: 840371 January 31, 1985 TO: Permit Applicant SUBJECT: Lot 6 Block 2 Glacier View Heights Subdivision #4 A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1984. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site sewer system, the original as-built inspection report and the yellow copy must be sent to this office for review and approval, and for documentation. If there are any further questions, please call this office at 264-4720. Sincerely, Environmental Engineering Program KEB/ljw enc: Copy of Permit SWP/057 1 Municipality of Anchorage • Development Services Department Building Safety Division e On-Sfte Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. o a -o Y-ei yo HAA #711 (� 2 Expiration Date: ��TZ 1 GENERAL INFORMATION v fi.Ompferte fega{ description /'���,f� !/.f,,, ,yi.,r9,vzs 10'y JBG,er .4 en Location (site address ar directions) dig ;ryS oc Current Property ownelr(s) ,"� ja" E;w re . Day phone '7;t9- 1-%50 Mailing address Lending agency Mailing address ZZ7g3 z azir -c t r"P Day phone Real Estate Agent BE" %t"f Day phone 241— 760o Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the . Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and,State codes, ordinances, and regulations in effect at the time of installation. p Name of Firm .froze .hersPhone Fr `�q-6.7 Address io+rsri dir/ .P.e seg r& toi Engineer's Printed Name ,I' le.is(co S. DSD SIGNATURE Approved for Disapproved. _ bedrooms. Conditional approval for bedrooms, with the following stipulations: Attachments: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By: t M Original Certificate Date: (Rev. OV7q Municipality of Anchorage bF ' Development Services Department Building Safety Division On -Site Water & Wastewater Program ' " E T ` n 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: z5f_4a,,W.r !/ems //r, �y 744-- 2 Ar 6 Parcel ID: oSB 3'0/ yp A. WELL DATA Well type �' &"y.— if A. B, or C provide PWSID # _ Date completed Sxlrolv y, Sanitary seal d9N) � Total depth _ /�Yy ft. Cased to ✓yy ft. FROM WELL LOG Date of test Sz.90 Ary Static water level S3 ft. Well production 3 g.p.m. WATER SAMPLE RESULTS: Coliform _Qcolonies/100 mi. Nitrate <644 mg./I. Arsenio 6 mg./I. Date of sample: 104YI y B. SEPTIC/HOLDING TANK DATA Tank Type/Material Tank gize 1.?S- gal Number of Compartments 0 Well LogC/N) .A i Wires properly protected ON) y o:I Casing height (above ground) 3 Z in. AT INSPECTION', LVf .z/ a y 3. I g.p.m. Other bacteriaO colonies/100m]. Collected by: L.q t4 R- )( ) ad b Date installed Y/t m. /irV Cleanouts (P)N) ym, Foundation cleanout (94 _y&�o Depression over tank (YS? .aD High water alarm (Yt0 ti/,s Date of pumping 9- /5 - DY Pumper Is C. ABSORPTION FIELD DATA Date installed t- as Soil rating (g.p.d./ft2 or ft2/bdrm) ,wiz System type T,e�,e�csr Length /H3 ft. Width ft. Gravel below pipe .2 ft. Total depth y ft. Eff. absorption area/yxi ft2 Monitoring tube�Z Depression over field .✓D Date of adequacy test._dtV?/ei Results Fail) A o For 1o' bedrooms e' Fluid depth in absorption field before test /.2 in. Water added rgmogai. New depth/ea in. Elapsed Time: _e,4;' Final fluid depth /0- in. Absorption rate >_ Gmo g.p.d. Any rejuvenation treatment (past 12 mo.) (Y4ZPL type) .✓ If yes, give date Date installed Size in gallons 7 anhole/Access (Y/N) "Pump on" level at _in. Pump o " Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO Septic tank/lift station on lot f too' Absorption field on lot 4100, Public sewer main f Vtr, Sewer/septic service line ► P-5- in. High water alarm level at in. Meets alarm & circuit requirements? On adjacent lots -F /do ) On adjacent lots -r 100' Public sewer manhole/cleanout +i u o' Holding tank t toe, SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation /D' Property line to- ' Absorption field c' Water main +/o' Water service line -c 1 u 0 Surface water t 0 " Wells on adjacent lots -r., 400' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line /v' Building foundation .?S " Water main +to' Water Service line Y iDSurface water '► 1400 , Driveway, parking/vehicle storage 3y, Curtain drain -SSV Wells on adjacent lots re D' w A -'"a Mn,aw. ' F. COMMENTS G. ENGINEER'S CERTIFICATION 1 certify that I have determined through field inspections and �yr� w_ vD+ review of Municipal records that the above systems are in ss CHRISTOPHER R WOOD conformance with MOA HAA guidelines in effect on this date. + �� Engineer's Printed Name e.ary orcz .� ic%w.a ...,P*..�� Date 1(!) HAA Fee $ nb • oo Waiver Fee $ Date of Payment II Date of Payment Receipt Number INIC)Z9 -IPt Cllr Receipt Number (Rev. 12/01) THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTMUTIONSSPECIFICALLYTO SHOW ANYCONFUCTS BETWEEN EXISTING STRUCTURES AND PUTTED LOT UNES OR EASEMENTSAND IS NOTTO BE USED FOR POSITKININOADDITIONAL STRUCTURES OR FENCEUNES EASEMENTS OF RECORD, OTHER THAN THOSE SHOMM ON THE RECORDED PUT, ARE NOT SHOWN HEREON. NOTE ANY FENCEUNES SHO" ARE LOCATED APPROXIMATELY AND ARE NOT TO BE USED TO DETERMINE PROPERTY LINE OR LOCATESTRUCTURES. ANY PAWINGSHOAN MAY SEAPPRO)UMATE DUETO SNOW CONDITIONS. ASBUILTSURVEY SCALE: 1' a 10' I HEREBY CERTIFY THAT 1 HAVE PERFORMED A MORTGAGEES INSPECTION OF THE FOLLOWING DESCRIBED PROPERTY. LOT B, BLOCK 2, GLACIER VIEW HEIGHTS 140.1 ANCHORAGE RECORDING DISTRICT, ALASKA AND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND THAT NO VISIBLE ENCROACHMENTS E)UST OTHER THAN NOTED. DATED AT ANCHORAGE, ALASKA THIS iBTH- DAY OF OCTOBER 1001 HOLT LAID SURVEYING 3381, FB 31 -,, 1472 TEL. 315-9513 MUNICIPALITY OF ANCHORAGE DIVISION OF ENVIRONbLENTAL tLEALTH DEPAR~IENT OF HF~kLTH AND ENVIRONMENTAL PROTECTION APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE 1 General Information ~cation Date ,h'~/~ b/?~j (a) Legal Description (include lot, block, sub~%~i~_., section, township, range) (b) Applicants Name Applicants Address (c) Applicant is (check one) Lending Institution Buyer ~ ; Other ~--'-. [ (explain); (d) Lending Institution Address .~-o>~ %~, ~ Telej2hone -- Home Business ............ T___ele~p~one (e) Real Estate Co. & Agent Address Telephone (f) Mail the HAA to the following address: 2..T~y_pe of Residence Single-Family [~i ~ Number o£ Bedrooms 3. Water Sul0p17 Individual We].~.~'---~ . Multi-Family Other (describe) Note: If community well system, must have written co[~firmation from the State Department of Environmental Conservation attesting to the legality and status. 4. S e wa~._e __D i_.~p.o s a 1 Note: If community well system, must have written confirmation from the State Department of Envirorm~ental Conservation attesting to the legality and status.. [Page 1 of 21 5. En__g. ineering Firn Providing Inspections; Tests, File Searchz Data and Infotnnation. As certified by my seal affixed hereto and as of the validation date shown below, I verify that ny investigation of this Health Authority ApprovaI'shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedroons and type of structure indicated herein. I further verify that, based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal systen is in compliance with all Municipal and State codes, ordinances, and regula~ tions in effect on the date of this inspection. blame of Firm Date (ENGINEER SEAL) Approved for bedrooms Approved "." Di sappr oved Cond i t ~ onal 6. DHEP A~roval I..--' . "-~, By .'. " ' ' CAUTION THE MUNICIPALITY OF ANCIIORAGE DEPARTMENT OF HEALTH AND EiWIRONMENTAL PROTECTIO~I (DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON TIlE REPRESE,hU.~ ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIO~kL ENGINEER R~,GIS~ERED IN T~IE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND THEIR IJ~NDING INSTITUTIONS IN ORDER TO SATISFY CLR1A.[N FEDEILAJ., AND STATE REOUIRE- MENTSo EMPLOYEES OF DHEP t30 NOT CONDUCT INSPECT. IO?~5 OR ANALYZE DATA BEFORE A CERTIFICATE IS ISSUED. TIlE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIOMS IN THE PROFESSIONAL ENGINEER'S WORK. (DHEP $EzkL) RR4/ej/D1.8 [Page 2 of 2] 7-'1 9-8z~ WELL DATA MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 Legal Description: 1984 Well Classification Well Log Present (Y/N) Total Depth / L/~- Cased to Static Water Level Casing Height Abov~ Ground ~l / Electrical Wiring in Conduit (Y/N) Separation Distances from Well: To Septic/Holding Tank on Lot_. If A, C, /~/~/ Depth of Grouting Pump. Set At / Sanitary Seal on Casing (Y~__~_~_ Depression A~ound Wellhead (Y/N) ~.~ ; On Adjoining Lots To Nearest Edge of Absorption Field on Lot. /o~ '~ ; On Adjoining Lots To Nearest Public Sews. r Line /~/~x¢~ To Nearest Public Sewer Cleanout/Manhole /L/~ To Nearest Sewer Service Line on LOt Water Sample Collected By /~'~ ; Date Water Sample Test P~sults ~'~-~ Cor~rents --~ ~3 ~-~/~r .. SEPTIC/HOLDING TANK DATA Date Installed ~/l ~/~ ~ Size / ~ Standpipes (Y/N) y Air-tight Caps (Y/N) Depression over Tank .(Y/N) /L7 Date Last Pumped ~/~ Pumping/Maintenano~ Contract on File (Y/N) ~,. ; for .... Holding Tank High-Water Alarm (Y/N) ./'~ Temporary Holding Tank Permit (Y/N) Separation Distances f~cm Septic/Holding Tank: To Water-Supply Well ?~z~ '~ To Building Foundation To Property Line /~ f- To Disposal Field_ To Water Main/Service Line ~ 7L Course No. of C~%~artmmnts 22_ Foundation Cleanout (Y/NJ To Stream, Pond, lake, o~ Major D~ainage [Page 1 of 2] 2-15-84 Ce ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field Square Feet of Absorption A~ea Depression over Field (Y/N) .%// Date .of Last Ac~quacy Test Type of System Design Length of Field -~ /L/~ / / Depth of Field ~/5- Gravel Bed Thickness ~ ~, ~ Standpipes P~esent (Y/N) Results of Last Adequacy Test /~/e~ ~_~,~ 2k~. (~ Separation Distance from Absorption Field: To Water-Supply Well /~ M To P~operty Line /~ p To Building Foundation ~ ~, 3- / To Existing or Abandoned System an Lot /b/~- ; On Adjoining Lots ~ :~ To Water Main/Service Line .~ '~ To'Cutbank(if present) /~w~ To St~eam/Pond/Lake/or Majo~ D~ainage Course /~_ To D~iveway, Parking A~ea, or Vehicle Storage A~ea ./~ ~- LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes(Y/N) Con~ents Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles du~ing Adequacy Test. Meets MOA ** Check Permitted Bedroom Rating Against HAA ~quest I certify that I have checked, verified, or conformed to all MOA HAA Guidelines in effect on the date of this inspection. ~;~, 4 9 ~I~G.~N~ERS KB1/d5/s ... 4~ .~. ~.~. ~'-" ,,-~; No. 2 2 ~ 5-/. ~t ~'. JUNE 25,