Loading...
HomeMy WebLinkAboutGLACIER VIEW HEIGHTS #4 BLK 3 LT 2 Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/Or Well Inspection Report Permit Number: SWq~ooz-I PIDNumber: %me'~'r-/Z/C/,~.,, ,4~. /~¢a,~-~ Wastewater System: [] New [] Upgrade "~ddress: ABSORPTION FIELD ~he~e~ No. of Bedrooms: ~/~O~ .I O~ ~ ~ Deep Trench ~ Shallow Trench ~ Bed ~ Mound ~ Other_ LEGAL DESCRIPTION soi, Rating: Total Depth from original grad~: ~, ~ GPD/Sq. Ft. Lot: Block: , ~ Subdiv~ion: ~ Depth lo pipe boltom from original grade: Gravel depth beneath pipe -I Section: Township: ~ Range: Fill added above original grade: Gravel length: WELL:~ New ~ Upgrade Grave~ width: Number of lines: Dista.ce between lines: G Ft. / ~/~ Ft, ~lassiflcation (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: ~¢/~ _ ~lV~ /0( Ft. /6/ Ft. '~SQ. Ft. ~5~ /~203~ ~ V,C. -- Driller: Date Drilled: Static Water Level: Installer: Date installed: Yield: Pump Set at: Casing Height Above Ground:! /~ GPM Vk~~t, z .t. TANK _ SEPARATION DISTANCES ~Septio U Holding ~ S.T.E.P. To Septic Absorption Lift Holding Public/Private Manufacturer: Capacity in gallons: From Tank Field Station Tank Sewer Lines ~C~ ~J ~ WelV //~ / it~t ~ Material: Number of Compartments: su,~o~ '+ '+ LIFT STATION Water / ¢ ~ ~~ Manufacturer: Lot Line /O /O '+ ~ "~' ump on"/~level at: "Pump~ Foundation / ~ / / ~ / ... o~~~terl Hioh wa alarm at: Curlain Pump Make & Model I Electrical Inspections pedormed by: Drain ~0~¢ ~0~ , Remarks: BENCH MARK Location ~nd Description: FO O~P~T/om~ -- Assumed Elevation: /oo .~ Fl, ENGI~EE~ SEAL 17034 Eagle River ~,.;c,p , .,,.., Inspections performed by: Eagle RIver, Alaska 995~7 Dates: 1st ~ -z ~ ~~ces a~al Department of He__~~um~~ ~ Reviewed and approved b~~~ Da~~ Permit No.S'W940°21 2 2 Page of Municipality of Anchorage DEPAR'rMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report GLACIER VIEW HEIGHTS SUBDIVISION //4, 05050126 Legal Description: BLOCK 3, LOT 2 PID No.: ~0) 98.~' ~2 FINAL GRADE ~ ............................... ~......~F,~ .......... ~ ................... ~ ................ ..~ ........ 9~.9~ ~ ~50 GA~ ~947, N.T.S. MT~ 91.0'~/ ¢/~- 97.5' 94.0' C04 · 83.0' WATDI{ FOUND 1-17-94 A B FCO g.0 10.0 CO1 11.0 16.5 C02 19.0 23.0 CO~ C04 89.0 89.0 MTi 23.5 34.0 MT2 89.5 88.5 HOUSE/ N i0F LOWEST SECTION OF [~OU NDAT~ON 1250 GAL. SEPTIC TANK BL CO SCALE l" = 40' TR[ NCH EN6 SEAL 72-013 A (1/93) · rtifiei rill ng b) DOC Co. SULLIVAN WATER WELLS P.O. BOX 670272, CHUGIAK, ALASKA 99567 · TELEPHONE 688.2759 OWNER OF LAND r~L ~ESCm~ON DATE-Started Ended PERMIT NUMBER KIND OF FORMATION: From~ Ft. to a~ Ft. (~'t44''t'~1~ '~r"~"ff~'~d~ From Ft, to From~ Ft. toq , Ft. ~ 0~ ~Oe~ From~Ft. to~ From ~ Ft. to~ Et ~/(.~ f~/~ ~' ~O~ From~_Ft. to~__ From_~ ~ Ft. From '7 ~:~ Ft. From_~t ~"Ft. From___Ft. to Ft. From__Ft. to Ft. From~ _Ft. to Ft.. From_ Ft. to Ft. From ,,Ft. to Ft. From Ft. to Ft. From Ft. to. Ft From_ Ft. to Ft __ From .Ft. to Ft. From , ..Ft. to Ft. From Ft. to , Ft. to 7~ Ft. ,o q,5 Ft. to / ~a'~',Ft. From From _ From From From From __Ft. Ft. Ft. Fi Ft Ft. Fl. Ft. __Fl, Ft. Ft. to Fl _Ft. to Ft, _ _Ft. to___Ft, F' '0 ~'t': r L' I V ED .... __Ft. to____Ft. Ft. to FdUL .2 5 1994 Ft to M uqJf2~y_ot Anchorage ' ' -q-v~-~;~'~gTvF;~-Human Serviuus' Mil,mC L. INFORMATION: PAGE 1 OF MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW940021 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:MORGAN PATRICIA M OWNER ADDRESS:38470 GRIGGS88 LEBANON, OREGON 97355 DATE ISSUED: 2/04/94 EXPIRATION DATE: 2/04/95 PARCEL ID:05050126 LEGAL DESCRIPTION: GLACIER VIEW HEIGHTS #4 BLK 3 LT 2 LOT SIZE: 44952 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: · " ~>-- ROBERT SHAFER1 P.E. ROGER SHAFER, P.E. January 28, 1994 CIVIL ENGINEERS (907) 694-2979 FAX 694-1211 HEALTH AUTHORITY APPROVALS SEWER & WATER MAIN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SiTE PLANS ROAD DESIGN SOIL TEST Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 'L' Street P.O. Box 196650 Anchorage, Alaska 99519-6650 REFERENCE: Lot 2; Block 3; Glacier View Heights Subdivision Request you issue a permit to drill a well and install a septic system to serve l'~heproposed four[~oo~houseon'bhe referenced pro~y. Test holes were excavated and percolation tests performed. The approximate location of the test holes are located on the attached site plan. At the time of excavation water was encountered in test hole #1 at 13 feet and in test hole 92 at 13 feet. After seven day ground water monitoring water was found at 13 feet and 14 feet, respectively. This property has enough area for a future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring properties by the installation of the proposed septic system. If you have any questions, or require additional information for your review, please contact us. PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS A. Shafer, P.E. ./LSU/jk Ref: MOASINGLET ON SITE WASTE WATER DISPOSAL SYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 o \ \ NVqd 3ils o om~O oom~ x ~×~$ ~z ~0~o ]qVO8 NVqd Ills ,Og = ,,[ ON-SITE WAST~ATER DISPOSAL CONb~IRRUCT ION PRACTICES MATERIAL SPFX]IFICATIONS ~CZ: Lot 2; Block 3; Glacier View Heights Subdivision 1. The scope of this project includes the installation of a 1250 gallon septic tank and five foot wide drainfields to serve the proposed four bedroom residence for the referenced property. 2. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The contractor shall be responsible for obtaining any necessary underground utility locates. 4. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEP~ICTANK INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 4. Septic tanks installed with less than 4' of cover shall be insulated. Page Two Lot 2; Block 3: Glacier View Heights Subdivision January 28, 1994 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10' from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENC]]/DRAINFIELD INSTALLATION: 1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (roughed-up) before gravel (sewer rock) placement. 2. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitor tubes shall be of four (4) inch diameter and installed approximately in the locations shown on the design. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 5. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. MINIMUM MATERIAL SPMC]i~ICATIONS: 1. Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Page Three Lot 2; Block 3; Glacier View Heights Subdivision January 28, 1994 T~pe of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be ~pproved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140/N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. Ail leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2o The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required, especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction Page Four Lot 2~ Block 3: Glacier View Heights Subdivision January 28, 1994 meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractor's activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit, there will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractor's activities. Final acceptance of the contractor's work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER Municipality of Anchorage DEPARTMENT (DF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST ENGINEER'S SEAL) ' ' LEGAL DESCRIPTION: ('~L/:I~,~J% dlEY~//~.. ~2., ~?('?,) Township, Range, Section: / SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? I F YES, AT WHAT ~?~:~[/"'~ DEPTH? ~ [3' 1 2 3 4 5 6 7 8 9 10 11 12 13- 14 15 16 17 18 19 2O OepthtoWaterAilermonilorin9? /,'~ f Date: ~'"(l~.~ Gross Net Depth to Net Reading Date Time Time Water Drop .51/o -- 5 ,/.~ ,, - !ad to~,¢ 6%" COMMENTS ~ - -- S & S ENGINEERING ,.'"" // ,/u,se ~agm myer t. oop aoac~ No,204 r,~'--~ PERFORMED BY' I=adle Iilv,r Al~lr3 ~77 ,,/-""- /1~ .¢-' ' CERTIFY TNA~ THIS TEST WA8 PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL 6UI~ELI~¢~E~T ON THIS DATE. DATE: 72-008 JRev. 4/85) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13 14- 15 16 17, 18 ( E.,N..-GI NB E P~'~ SEAL) DATE PERFORMED': (.Jll.~.a ~T5/ /_.~2, ~_.~) Township, Range, Section: SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, ATWHAT DEPTH? Deplh to Waler Aft~r I Reading 19 SITE PLAN Date Gross Time ~ . Net Time lO II Depth to Water 6 %1" ""¢ t/B Drop PERCOLATION RATE ~ ~m d'u9 inch) PERC HOLE DIAME ER _ _ 'TEST RUN BETWEEN COMMENTS // PERFORMED BY: ~Je ~iveF. Alack. ~q~7~ i ~' ~ ~ .... OERTIFY THAT TEllS TEST WAS PER ORMED /1~/ I I :~-,THI DA~E DATE ACCORDANCE WI~H ALL S~ATE AND MUNICIPAL GU DELNE¢ '~F~T / 72-008 (Rev. 4/85) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES. Division of Environmental Services On-Site Services Section P.O. Box196650 Anchorage,'Alaska 99519-6650 · 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # 1. GENERAL INFORMATION Complete legal description Location (site address or directions) Property owner' Mailing address Mile 4.5 Eagle Rivet Rd. Ea~le Glacier Loop & Columbia Gla~i~r Loop EAGLE VENTURES Day phone 696-5534 P.O. Box 771822 Eaqle River, AK 99577 Lending agency Mailing address Day phone Agent Address Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: 4 TYPE OF WATER SUPPLY: Individual well Community well Public water XXX NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. , ~',~' .:.. '. ; ~,, ' ,' /~ ',. .~.. Community on-site - · . , ., ,/~ .~ .. ~,~. <-. ., , Public sewer .... . ...... ?, ,,, ,,,,- t ,,..-~,~.:. .... -.. NOTE: If community, wastewater system, provide written confirmation from Sta~e. ADEc attesting to the legality and status of system. 72-025 {Rev, 1/91) Front MOA#21 4. TYPE OF WASI'EWATER DISPOSAL: Individual on-site XXX · ." · ' Holding~a'nk .,-- '. ~, ' : ' - 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Muhicipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance ,with all Municipal and State codes, ordinances a.nd,regu,lations,., in effect ¢ his i~spection.,.,.. :, , .. :~ - S & S ENGINEERING Name of Firm Address Engineer's signature DHHS SIGNATURE ? Approved for ¢ Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations:..',: · Additional Comments "- The Municipality of,~(~horage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work...!:,~ : ,,:: i., : ':: ' ; ' 72-025(Rev. 1/91) Back MOAtY'Zl ' : . ,':: '' ' Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description' ----c,¢'Z-- Parcel I.D. · A. Well Data Well type Log present ~N) Total depth / o / / Sanitary seal ({~) / If A, B, or C, attach ADEC letter. ADEC water system number Date of test Static water level -~/--¢ J Well flow / '~"- FROM WELL LOG Pump level1 UJ IZ_ SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot / / ~ ~ Absorption field on lot / ~ ~ ~ Public sewer main Sewer service line '~,~- ~ ~ Date completed Driller Cased to ~O /~ Casing height Wires properly protected ~N) / AT INSPECTION ; On adjacent lots ; On adjacent lots Public sewer manhole/cleanout Petroleum tank WATER SAMPLE RESULTS: Coliform ~ Date of sample: Nitrate Collected by: Other bacteria El. SEPTIC/HOLDING TANK DATA Date installed ~ - & ~ ?/¢¢ Cleanouts (~N) ¢ High water alarm (Y/.~ Date of pumping Tank size / 2--~ Compartments Foundation cleanout {~N) / Depressiop (Y~ /d' Alarm tested (Y/N) "[//~- /'//,4- Pumper Z.~: ~;_s ~--,~/.,~--~ ( ///~, SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot / I ~ ~ On adjacent lots To property line /O Absorption field Surface water/drainage / O 0 / 4- Foundation /0 ~ Water main/service line 72-026 (3/93)' Front CONTINUED ON BACK PAGE C. LIFT STATION Date installed Manufacturer Size in gallons Manhole/Access (Y/N) Vent (Y/N) "Pump on" level at "Puj.r~:~-e~vel at High water alarm level ~~ Meets MOA electrical codes (Y/N) SEPARATION DIS%~SE'F~ROM UFT STATION TO: ~ lot On adjacent lots Surface water D, ABSORPTION FIELD DATA Date installed Length ~ / Total absorption area Date of adequacy test Water level in absorption field before test Peroxide treatment (past 12 months) (Y~ Soil rating (GPD/FF) z~, Width ~" / Gravel thickness 75~B /¢ Cleanout present ~'4) ~¢/ ~_.¢I- ~/''/E~,--/ Results~/fail) f¢',4¢ 5' System type ~,'/,¢¢~--~ 3 · Total depth Depression over field (Y/.._~ for '/7/ Bedrooms After test If yes, give date SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot / / ~ ! On adjacent lots To building foundation /~ ~ On adjacent lots -~ ~' / ~- Cutbank Surface water /O o f w- Curtain drain 'U/,,~ Propertyline To existing or abandoned system on lot / Water main/service line Driveway, parking/vehicle storage area E. ENGINEER'S CERTIFICATION Signature ~ ?&~ r~Sa~N,G. I~ ~ :E..~ .'. ,N _/_/_/~ 2~ HAA Fee $ k._~' O0' '~¢- Date of Payment ~' ~ "~ ~ ), ~. Receipt Number ~.L.,_2-~ ~.~ ~--k..~7 72-026 (3/93)' Back Waiver Fee $ Date of Payment Receipt Number