HomeMy WebLinkAboutFAMILY SERVICE CENTER Tract A S-5135
MUNICIPALITY OF ANCHORAGE
DEPAR'FMENT C)F HEALTH & ENVIRONMENTAL PRO'FECTION
Environmental Health Division
CASE RIEVII"W WOFIKSHEI-'T
CASE NUMSER:
S-7448
DATE RECEIVED; COMMENTS DUE BY:
January 23, 1984 February 3, 1984
SUBDIVISION OR PROJECT TITLE:
Family Service Center Subdivision
~ (~ PUBL'O WATER AVA'LAB[E ~ ~ ' I (B/f/PUBL,CSEWER AVAILABLE
I )COMMUNITY WATER AVAILABLE
COMMENTS:
71-014 {Rev, 5153)
MUNICIPALITY OF ANCHORAGE
DEPAR'FMENT OF HEALTH & ENVIRONMENTAL PRO'FEC'TION
Environmental Health Division
CASE RIEVIFW WOI:IKSHEI"T
CASE NUMBER: DATE RECEIVED: COMMENTS DUE BY:
S-7289 Sep%ember 29, 1983 October 14, 1983
SUBDIVISION OR PROJP'CT TITLE:
Tract A Family Service Center Subdivision
( ?'~? i'FUBLIC WATER AVAILABLE (/l~ ~' PUBLIC SEWER AVAILABLE
( [,' ) COMMUNITY WATER AVAILABLE
COMMENTS:
71-014 (Rev. 5/83)
820 "L" STrtEET
ANLHOI~AG :, ALASKA 99501
(907) 264-4111
September 19, 1980
Douglas A. Stark & Associates
957 Westbury Drive
Anchorage, Alaska !)9503
Subject: Case #5135 - Family Service Center
A review of the subject case shows that: Tract A, the Baptist
Convention Building sewer system was approved June 10, 1974.
The as-builts on the Baptist Family Service Center on-site
sewer system was received September ].7, 1980.
This department can not address Tract B and review the soi]_s
test as submitted. Our concerns are 90% of the tract(50.0019 acres)
has a high water table with a marsh at the east end.
The only soils test submitted that can support an on-site septic
system are test holes #1 and #2 with the unified soils
classification rating of 225 to 250 square feet per bedroom.
The test also shows a water table in test hole #2 at thirteen(13)
feet.
Tile Family Service Center, Tract B; also noted as Parcel ~2 of
the Ew~ns Family Service Center, cannot be approved as a whole.
The recommended conditions of approval are; no development of
Tract ]3 or noted as Parcel It2(50.0019 acres) until public
sewer is available.
If there are any further questions, please ca].l this department
at 264--4720.
Sincerely,
John W. Lynn
Environmental Specialist
JwL/1 j w
cc: Jerry Weaver
Planning Department
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
PLATTING OB PLANNING AND ZONING CASE REVIEW
CASE NUMBER S-5135
PETITION FOR
DATE RECEIVED
REZONING
SPECIAL EXCEPTION
VACATION
RE6UBDIVISION
March 30, 1979
COMMENT TO PLANNING BY 4-18-79
OF PUD Family Service Center Sub.
FOR MEETING ()F
of - Cases
COMMENTS:
ENVIRONMI--NTAL SANITATION:
PUBLIC WATER NOT AVAILABLE
PUBLIC SEWER NOT AVAILABLE TO SERVICE PETITION ARFA,
7%014 (9/76)
M[JNICIPALITY 05' ANCHORAGE
PLANNING AND ZONING COdMI~SlON RESOLUTION
26- 791_,
A RESOLUTION APPROVING 'i'HE SUBDIViSiON OF A PLAHNEO UNIT
DEVELOPblEN~? IN TiIE R-6 ZONING DISTRICT 'LO~.~.~aO~'~"' .... ~OJ~-,Ao,.'~e -~- OF
WHEREAS, a petition has been received f~:om L~ma!d
B, }]off and Alaska Baptist Convention for approval of a
s. ubdivision of a 69.88 acre unsubdivided parcel to be known
as Family Service Center Subdivision, located in the NW ]/4,
NW 1/4 and NE 1/4, NW 1/4 of Section 20, T].2h
WHzREAS, notices were posted notices were raailed,
notices were publis.hed, and a public hearing was held, and
WHEREAS, the Commission has approved a
acreage of the PI. anneal Unit Development locahed
cel, and
reduction in
on the par--
WHEREAS, the proposed subdivision reflects the
reduced acreage and is consistent with the boundary of the
re,saShing parcel, and
WHEREAS, conditions of approval have been insti-
tuted to assure the appropriateness of the request.
NOW, THEREFORE, BE IT RESOLVED by the Municip~%l
Planning and Zoning Conlmission that the request on the
above described parcel be approved subject to tile following
conditions: ~-
1. Resolve utility easements. '~ '~ ~'~ /~/~'g~'~<~ ~7~:~/f~'
i~_l~-\~ Resolve access w~th 'lb:aff~c Engineering.
3~/ De. dication of 30 feet of right of %;ay to march existing
£ 30 feet: of Reader Road along east property line.
Resolve creek maintenance easement for Furrow Creek and,
prior to any development, erosion and sediment control
~ plan with Public Wor]<s Engineering,
~.~ /5. Reso~,ve soils" information with the Department of Healthh
~( and Environmental Protection prior to any development.
' ~:~ ~ '~'--~ PASSED AND APPROVED by the Municipal'Planning and /
Zoning Comfaission this 1].th day of June, 1979.
~Ifctyael ,J. bl~ha~/, Secretary
Grant G]esler, Chairman
RM/gh (P-79-21 Al)