ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP191253 PID Number: 015-243-34
Dwelling: ❑i Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑■ Upgrade
Name
KELLY POSTON
ABSORPTION FIELD
❑ Deep Trench ❑■ Wide Trench El Bed ❑Mound
Site Address
11601 HILLSIDE DRIVE *ANCHORAGE, AK 99507
❑ Other
Phone
Number of Bedrooms
Soil Rating
depth from original grade
907-240-2319
4
1.2 GPD/SF
JTotal
8 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
SEE DWG. Ft.
Gravel depth beneath pipe
4.02 Ft.
Subdivision Block Lot
ALPINE TERRACE; BLOCK 1, LOT 10
Fill added above original grade
SEE DWG. Ft.
Gravel length
25+25=50 Ft.
Township Range Section
N/A
Gravel width
5 Ft.
Beds: Number of Lines
-
Distance between lines
- Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
500 Ftz
1
- Ft.
Well
100'+
100'+
N/A
N/A
25'+
TANK X Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer Capacity
INFILTRATOR 1530 Gal.
Surface Water
100' +
*80'+
N/A
N/A
Material
HDPE
Number of compartments
2
Lot Line
5'+
10'+
N/A
N/A
NA
Foundation
10'+
10'+
N/A
N/A
LIFT STATION
Manufacturer
N/A
Capacity
_ Gal.
1
1
I
Remarks OLD TANK DECOMMISSIONED PER UPC
PER CONTRACTOR *WR#OSV191059
Alarm location
Electrical installed by
PIPE MATERIAL House to tank D3034 drainfieldTank to
D3034
Installer
A+ HOME SERVICES
Drainfield D3034 CO/MTD3034
Inspector DAVID GARNESS & TIM ECKLUND
BENCH MARK (Assumed elevation) 99.73 ft
Inspection 151 7/8/2019 7/29/19
Location and description
2nd
OF MANHOLE
3`tl 7/29/19 4117/29/19
ITOP
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
OF.A����4
Conditional Approval: Date
QQ�P.. ..•,�40
T
oma. 4 00
........... .................
Septic System
O •.J A. ess:Q
00 E 7953 �QQ
Approved (/r(1L _ QC!UZ Date q 30
4p�� e '•. �� �o�Q
Note: this approval does not include well permit requirements.#nec1884
��Oo0o� c'
(Rev 05/02/18)
PERMIT NUMBER:
OSP191253
A I B I C
MH
33.7
14.5
36.8
ST1
25.6
15.3
46.8
DBL1
26.9
17.1
46.7
DBI -2
27.6
18.1
46.8
C01
68.4
55.6
47.0
MT1
66.6
54.5
47.5
CO2
37.3
26.7
44.1
MT2
1 35.7
1 25.1
44.3
MT3
1 54.5
1 34.8
25.6
I
I
I
I
I
I
I
I
I
RECORD DRAWING
NEW DRAINFIELD
��, :�, OM1. •
r <' v'•
PARCEL ID NUMBER:
015-243-34
NEW IM -1530 INFILTRATOR SEPTIC TANK
SHED
DBL182 0
/A
1 C T2\ I>.
T1 '� •,
H .B DECK
H.#1 \ FCO
C� EXISTING '� •,�..�•, •+•:
\ BEDROOM HOUSE
ENGINEERING o SALES o CONSULTING ---- --------
3701 E. TUDOR ROAD. SUITE 101 -ANCHORAGE. AK 99507 • PHONE (907) 337-6179 • FAX (907) 336-3246' WEBSITE: w+ rv/.gamessengineenng.cam
PREPARED FOR:
PHONE NUMBER:
PAGE NUMBER:
I
907-240-2319
W
•i` r' CO T
80'+ TO ROAD t '• a'\
I
u
DITCH/SURFACE WATERS
N
:� .,.:�•'• .,. -tom'{,. '` �; •"'r � SHE
0 I
W I
;•
% T
9/25/2019
-j. DRIVEWAY .•' •'. '•'
•f aa.••.••,.
_ a
(APPROXIMATE
LOCATION OF
_I WATER
LINE PER ONE STOP
_ SERVICES
LOCATE - SEE
ATTACHED PHOTOS
NEW DRAINFIELD
��, :�, OM1. •
r <' v'•
PARCEL ID NUMBER:
015-243-34
NEW IM -1530 INFILTRATOR SEPTIC TANK
SHED
DBL182 0
/A
1 C T2\ I>.
T1 '� •,
H .B DECK
H.#1 \ FCO
C� EXISTING '� •,�..�•, •+•:
\ BEDROOM HOUSE
e4v �
I
ya�v ALPINE TERRACE; BLOCK 1, LOT 9 /
d
/ CSEPTIC
I ARE�D
GARNESS ENGINEERING GROUP, Ltd
ENGINEERING o SALES o CONSULTING ---- --------
3701 E. TUDOR ROAD. SUITE 101 -ANCHORAGE. AK 99507 • PHONE (907) 337-6179 • FAX (907) 336-3246' WEBSITE: w+ rv/.gamessengineenng.cam
PREPARED FOR:
PHONE NUMBER:
PAGE NUMBER:
KELLY POSTON
907-240-2319
2 OF 3
LEGAL DESCRIPTION:
DRAWN BY:
ALPINE TERRACE; BLOCK 1, LOT 10
D.J.G.
:� .,.:�•'• .,. -tom'{,. '` �; •"'r � SHE
I
SEPTIC SYSTEM RECORD DRAWINGS
9/25/2019
-j. DRIVEWAY .•' •'. '•'
•f aa.••.••,.
_ a
e4v �
I
ya�v ALPINE TERRACE; BLOCK 1, LOT 9 /
d
/ CSEPTIC
I ARE�D
GARNESS ENGINEERING GROUP, Ltd
ENGINEERING o SALES o CONSULTING ---- --------
3701 E. TUDOR ROAD. SUITE 101 -ANCHORAGE. AK 99507 • PHONE (907) 337-6179 • FAX (907) 336-3246' WEBSITE: w+ rv/.gamessengineenng.cam
PREPARED FOR:
PHONE NUMBER:
PAGE NUMBER:
KELLY POSTON
907-240-2319
2 OF 3
LEGAL DESCRIPTION:
DRAWN BY:
ALPINE TERRACE; BLOCK 1, LOT 10
D.J.G.
TYPE OF WORK:
DATE:
SEPTIC SYSTEM RECORD DRAWINGS
9/25/2019
Ql
V=40'
Ar
� c :
AV te •• ;
rey A. W i
# CE -795 i
.q.,N e17, 417
LICENSE #141k J%6FES"�.,.,�
#AECC884 i
PERMIT NUMBER:
OSP191253
RECORD DRAWING
TOP OF MH = 99.73
TOP OF TANK
AT INLET = 96.67
INVERT OF BUNG
AT INLET = 96.08
TH#1 ORIGINAL GRADE AT
HIGHEST POINT= 99.50
FINAL GRADE = 99.27-99.45
IM -1530 TWO-COMPARTMENT
INFILTRATOR SEPTIC TANK
�v►sje;p
PARCEL ID NUMBER:
015-243-34
2" HIGH DENSITY INSULATION
(PER CONTRACTOR)
— TOP OF TANK
AT OUTLET = 96.60
MT CO f— FINAL GRADE= 98.63-99.81
INVERT OF BUNG
AT OUTLET = 95.63
INSULATION OVER "WEST LEG' OF TRENCH PER CONTRACTOR
- FILTER FABRIC
RELATIVE ELEVATION OF BOTTOM OF T.H. = 83.0
(GW AT 14.1' BELOW GRADE ON 7/29/2017)
INVERT OF PIPE THROUGHOUT
DRAINFIELD = 95.52
BOTTOM OF TRENCH = 91.50
•��\\\\ 11,
41
--- -- - – — - --
AN
* • 4 ski
GARNESS ENGINEERING GROUP, Ltd(.O ............. .
- ---- -- -- - ---- - ENGINEERING o SALES CONSULTING ------------ -- - s
3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507' PHONE (907) 3376179' FAX (907)338-3246 ' WEBSITE: vrvrvi.gamessengineenng.com . . . . ...............•• ••., . 0
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ;•, rey . Games4-1 AV
KELLY POSTON 907-240-2319 3 OF 3 �Off
s�.- ' CE -79 :°
LEGAL DESCRIPTION: DRAWN BY: S.f AV
ALPINE TERRACE; BLOCK 1, LOT 10 D.J.G. Sj Fp p..l......... 48•
TYPE OF WORK: DATE: LICENSE 11 � :S`S` w��•
� SEPTIC TANK AND DRAINFIELD PROFILE 9/25/2019 #AECC884 i
SGS Ref.#
1194277001
Client Name
Garness Engineering Group, Ltd (GEG)
Printed Date/Time
08/07/2019 16:03
Project Name/if
Alpine Terrace B 1 L10
Collected Date/Time
07/31/2019 15:19
Client Sample ID
Alpine Terrace B1 L10
Received Dateirime
07/31/2019 16:15
Matrix
Drinking Water
Technical Director
Stephen C. Ede
Sample Remarks
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date Init
Metals by ICP/MS
Arsenic ND 5.00 ug/L EP200.8 B (<10) 08/05/19 08/05/19 DSH
Waters Department
Total Nitrate/Nitrite-N
Microbioloav Laboratory
E. Coli
Total Coliform
3.09
Negative
Negative
0.200 mg/L SM21450ONO3-F C (<10)
1 100mL SM219223B A
1 100ml- SM219223B A
08/02/19 EWW
07/31/19 VDL
07/31/19 VDL
i
is � - _. - _ _ .. - ._ •
+
•' t
Y.. i,rn i$ ter _ • ,dy,' •5 .
r. - - � �„' � � ,..�/.d' - y. +• r,_ ..tib �
CL
_ � r r�j •, • rX'.v ' = .. _ � 7 7 � _ .. Ir. r '•A S• r ,� .• NI
' y •. ii p'
IV
1 •� V
f.
'•1 5 g. i e � � 1 _
r t'r ti 1 ♦..
y, _ L' • r '1 1 F Y 4 _
�. '• � ,,. tr� � m � i�• r - .. ; -q t` 't � r S u n , re. L �, 3�{ r •
r ` s r tires-�_• r r. ��,,. r '� � _ ; r y. _ x m � f • -� - 'S + r •' F r i •� -
�— . _ _ _�.. .. �.___ ..l.__. _.�...__ �. _� r��._ �.__ .��=YyS"y'- _ __.a �..._�C i— _�_ _ ._-..J�� _ t...4 M t�=`._ a•W�_ __._.._ _."• _— •p.
OF ... �0
�., 49 TH �G
o a
s� SHANE A. HOLT a
ld� LS -6914
6pA'ofession?A
S 89 58' E 210.00
N 89 58' E 2 10. 00
THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY
CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS
NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES.
EASEMENTS OF RECORD, OTHER THAN THOSE APPEARING ON THE RECORD PLAT , ARE NOT SHOWN
HEREON ( UNLESS INDICATED)
NOTE: FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE
PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS.
ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE.
AS -BUIL T SURVEY i " = 30,
NO CORNERS SET THIS DATE
SURVEY ORDERED SY:
DAR ✓ILDE„
YELLER Mi LUAMS
I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY
OF THE FOLLOWING DESCRIBED PROPERTY
LOT 10, BLOCK 1, ALPINE TERRACE SUB.
ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE
VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN
THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS
EXIST OTHER THAN NOTED.
DATED AT ANCHORAGE, ALASKA THIS _6 TH DAY OF
_AUGUST , 2019
25C'5, lc2_40'
HOLT LAND SURVEY/NG
9309 GROVER DRIVE
ANCHORAGE,AK 99507
907223.8615
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP191253
Work Type: Septic . Upgrade
Tax Code Number: 01524334000
Site Legal Address: ALPINE TERRACE BLK 1 LT 10 G:2740
Site Mailing Address: 11601 HILLSIDE DR, Anchorage
Owner: POSTON MICHAEL R & KELLY E
Design Engineer: GARNESS ENGINEERING GROUP LTD
This permit is for the construction of:
R� Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy
Effective Date:
Expiration Date:
moment
O
De 1)a rtinent
Lot Size in Sq Ft:
Total Bedrooms:
6/26/2019
6/25/2020
44000
❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received B)
Issued By:
Date: 61 -?-4o
Date: b 611 %
TTI,unicipality of Anchorage-
P.O. Box 196650 ® 4700 Elmore Road
Anchorage, Alaska 99519-6650 0 (907) 343-7904 ® Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Department
On -Site Water and Wastewater Section
11�� Il t
A
L)cp:u•rment
x x x x VALIANCE/WAIVER REVIEW x x x x
Waiver#: OSV191059 COSA#: Permit#:OSP191253
PID#: 015-243-34
Legal Description: Alpine Terrace Block 1 Lot 10
Engineer: Garness Engineering Group
Applicant: Michael & Kelly Poston
Your request for a waiver of the required 100 feet horizontal separation from the absorption field
to the surface water has been approved. The approved separation distance is 80.0 feet. See
engineer's waiver request for j ustifications.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater- disposal system will require all separation distances be met or another
approval from this department.
■.............................................. ■ ....... t ..................... ■ 1
Waiver is Granted: X Waiver is not Granted:
Date:7 [,,/)I Approved by:�1.&nu
' Name of Reviewer
................... a ........................... ■ ............................. ■ 1
**** VARIAN C EMAIVE R REVIEW ****
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services
On -Site Water & Wastewater Program
Mayor Dan Sullivan
On -Site Sewer/Well Permit Application
For A Single Family Dwelling
Parcel I.D. 015-243-34
Property owner(s) KELLY POSTON
Mailing address 11601 HILLSIDE DRIVE "ANCHORAGE, AK 99507
Site address 11601 HILLSIDE DRIVE 'ANCHORAGE, AK 99507
Legal description (Sub'd, Block & Lot) ALPINE TERRACE; BLOCK 1, LOT 10
Legal description (Township, Section & Range)
Lot Size
APPLICATION IS FOR:
(Z all that apply)
Absorption Field
Septic Tank
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
56788
Phone: 907-343-7904
Fax: 907- 343-7997
Day phone 240-2319
Sq.Ft. Number of Bedrooms 4
APPLICATION IS AN:
Initial ❑
Upgrade
Renewal ❑
THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR:
DRAINFIELD TO SURFACE WATERS
TYPE OF DEWELLING:
Single Family (SF)
(w/wo ADU)
Duplex (D) ❑
Multiple Dwellings ❑
(SF and/or D)
Distance: 80 FEET
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees: o(2 Waiver Fees: 390 t q06
Date of Payment: % Date of Payment:
Receipt Number: _ OS 3�G Receipt Number: 69 -36
Permit No. Ospf f 2 3 Waiver No. V% A 10
(Rev. 01 /11)
GARNESS ENGINEERING GROUP, Ltd
— - - – ----- ENGINEERING SALES -CONSULTING =- -_ --- -
July 16th, 2019
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Proposed Septic System Upgrade for Alpine Terrace; Block 1, Lot 10
To whom it may concern:
Qual cs
____
AdvanCcd T.-ca[mcnt System de
O
The existing 4 -bedroom house is served by a private well and septic system. A tank permit was issued on 6/26/2019.
Per the approved permit, the drainfield was to be exposed and new C/O's and MT's were to be installed during the
septic tank replacement. During the tank install, it was noted that the existing drainfield did not have drainrock and the
distribution line was structurally unsound "Orangeburg pipe". Do to this fact, the MOA employee present (Tim Eklund)
determined that the drainfield would not be accepted and must be replaced. A testhole was excavated and the
drainfield was designed around its 30 -foot radius. Comments regarding the design are summarized as follows:
1. SOILS: See attached 2019 testhole by Garness Engineering Group, Ltd. which shows, soil classification,
percolation test and groundwater monitoring.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: See waiver request.
4. TOPOGRAPHY: There are no topography concerns.
5. WAIVERS: There is surface water approximately 85' west of the proposed drainfield. We are requesting that your
department issue a variance from drainfield to surface waters of 80 feet. Justification for granting this waiver is as
follows:
• The existing drainfield was installed in 1978. It is likely that the drainfield has always encroached upon this
"surface water".
• The surface waters may be intermittent.
• The driveway is located between the proposed drainfield and the surface waters. If effluent were to overflow,
it would be noted by the homeowner and corrective action taken.
• The home has a "daylight" basement. It is plausible that effluent would surface in the home, prior to
surfacing from the top of the cleanouts and/or monitoring tubes.
We are unaware of
any questions, plea
Ztffre�A.�C�arne P.E., M
Presi ent //
rse impacts this installation would have on adjacent wells or septic systems. If you have
t us at 337-6179. Thank you for your assistance.
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
CROMWELL HEIGHTS; / \
BLOCK 2, LOT 1 I /
w ❑ CARR; LOT 3A
li I I
VACANT PER MOA fy p�
RECORDS
Q o
_I r� :1si S9•L
ALPINE TERRACE;
BLOCK 1, LOT 5
THE SUMMIT;
\ 10 'WELL DIUS
I
\\ // (SEPTIC
ALPNE TERRA AREn
-131_00-rLOT9
/ ALPINE TERRACE;
BLOCK 1, LOT 6 - -
I I
I
THE SUMMIT; \
TRACT Al /
GARNESS ENGINEERING GROUP, Ltd
-- ENGINEERING � SALES CONSULTING ------ —
3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507 • PH(apE (907) 337-6179 -FAX (907) 338-3246 - WEBSITE: w .gamessengineering.com
PREPARED FOR:
KELLY POSTON
PROJECT/LEGAL DESCRIPTION:
ALPINE TERRACE; BLOCK 1, LOT 10
TYPE OF WORK:
SEPTIC SYSTEM DESIGN UPGRADE
PHONE NUMBER:
907-240-2319
PAGE NUMBER:
1 OF 2
DRAWN BY:
D.J.G.
DATE:
7/15/2019
1" =1100'
OF
. �P...........
E......... ...... .....v
O
♦♦♦ �=. ff Garn ss
♦ •'sl CE -79 •'
-7/h
LICENSE 1111O\\SS\Ok�' •
#AECC884 /
DESIGN CRITERIA:
NUMBER OF BEDROOMS: 4
GALLONS PER DAY (GPD): 600
PERCOLATION RATE/S: 1.33 MIN/INCH
PROPOSED APPLICATION RATE: 1.2 GPD/FT'
MINIMUM DRAINFIELD SQ.FT.: 500 FT'
DRAINFIELD DESIGN:
MAXIMUM DEPTH: 8 FEET
WIDTH: 5 FEET
LENGTH: 50 FEET
EFFECTIVE: 4 FEET
REDUCTION FACTOR: 0.5
ACTUAL SQ.FT.: 500 FT'
GEG, Ltd. HAS AN 8 PAGE SPECIFICATION LETTER
'_� . •„: _” APPROXIMATE LOCATION OF NEW
'•°%' •
PROPOSED DRAINFIELD
; IM 1530 INFILTRATOR SEPTIC TANK
THAT PERTAINS TO THIS DESIGN. BY PROCEEDING
�.... �(
NOTE: THE CONTRACTOR
............................ 0
FORWARD WITH THIS INSTALLATION, THE
SHED
SHALL HAVE THE WELL RADII
CE -79 AV
AV
ENGINEER, WELL DRILLER, CONTRACTOR AND
r; i9••.• 4v
FLAGGED BY A REGISTERED
PROPERTY OWNER AGREE THAT THEY HAVE
/
�':�•
READ THESE SPECIFICATIONS AND AGREE TO
LAND SURVEYOR PRIOR TO
ACCEPT THE TERMS AND CONDITIONS OUTLINED.
CONSTRUCTION.
THE PROPOSED DRAINFIELD IS PLACED
SURFACE WATER WAIVERST CARPORT :
OVER/THROUGH THE EXISTING
/
�j� M � °•�...,
\
DRAINFIELD, WHICH DID NOT CONTAIN
T.H.#1 � CF' •� �.':.
DRAINROCK PER GEG INSPECTION
\
CARR; LOT 3A
10' UTILITY EASEMENT
I- — — — — — — — ----- — — — — — — — — — — — — — — —— �I
APPROXIMATE (ASSUMED) LOCATION OF SUBSURFACE
DRIVEWAY DRAIN PER MOA RECORDS; NO C/O'S WERE FOUND
APPROXIMATE LOCATION OF AS SHOWN ON THE 7/1993 DRAWING BY TED MORE, P.E. ! \
/ SURFACE WATERS IN ROAD DITCH \
Ad
GARNESS ENGINEERING GROUP, Ltd
--_ — -- __ ENGINEERING o SALES,,) CONSULTING =---
3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 • PHONE (907) 337-6179' FAX (907) 338-3246' WEBSITE: w .gamessengineedng.com
PREPARED FOR:
KELLY POSTON
PROJECT/LEGAL DESCRIPTION:
ALPINE TERRACE; BLOCK 1, LOT 10
TYPE OF WORK:
11 DESIGN OF SEPTIC TANK UPGRADE
PHONE NUMBER: PAGE NUMBER:
907-240-2319 2 OF 2
DRAWN BY:
D.J.G.
DATE:
7/15/2019
T :
(AN
'_� . •„: _” APPROXIMATE LOCATION OF NEW
'•°%' •
PROPOSED DRAINFIELD
; IM 1530 INFILTRATOR SEPTIC TANK
•.....�
�.... �(
..
............................ 0
SHED
CE -79 AV
AV
�� ,,
r; i9••.• 4v
pROFESS1�Pi��'
LOCATE DRAIN OUTLET •�" • • '
/
�':�•
_�.
4.
SURFACE WATER WAIVERST CARPORT :
•{
coo -
/
�j� M � °•�...,
o
1
T.H.#1 � CF' •� �.':.
,,•
m
m
\ EXISTING 4 GRAVEL
BEDROOM HOUSE i : `' DRIVEWAY •%
z
i
GRAVEL
DRIVEWAY '
•` : J4. �..
'� •.
,.; �i. HE
. ,.}..:�•:.:��s.
f '
'. ` :..•.: • :+ `�
DRIVEWAY
Ad
GARNESS ENGINEERING GROUP, Ltd
--_ — -- __ ENGINEERING o SALES,,) CONSULTING =---
3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 • PHONE (907) 337-6179' FAX (907) 338-3246' WEBSITE: w .gamessengineedng.com
PREPARED FOR:
KELLY POSTON
PROJECT/LEGAL DESCRIPTION:
ALPINE TERRACE; BLOCK 1, LOT 10
TYPE OF WORK:
11 DESIGN OF SEPTIC TANK UPGRADE
PHONE NUMBER: PAGE NUMBER:
907-240-2319 2 OF 2
DRAWN BY:
D.J.G.
DATE:
7/15/2019
T :
(AN
•�
■.....:.....4
•.....�
�.... �(
..
............................ 0
Gar ess .- -Q M
CE -79 AV
AV
�� ,,
r; i9••.• 4v
pROFESS1�Pi��'
LICENSElI%k1%
#AECC884
/
GA,l,R'.Nl,v,.:jSS SEN GEN EERING GROUP, Lt: ENGINEERING SALES CONSd
3101 E. TUDOR ROAD. SUITE 101 'ANCHORAGE. AK 99507' PHONE (907) 337-6179' FAX (907)33"246 - WEBSITE: vnnv.game engineenng.cam
SOIL LOG - PERCOLATION TEST
LEGAL DESCRIPTION: ALPINE TERRACE; BLOCK 1, LOT 10
PERFORMED FOR: KELLY POSTON DATE: 7/8/2019
DEPTH
(feet) ORGANICS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
GM
SP
TEST HOLE #1
SOIL CLASSIFICATIONS
'
1111"111
NET TIME
(MINUTES)
WATER LEVEL
READING
112111w'I
i//iI
0:00
%��/%
MEN
•
wY,YY
111111111
6:42
'Rilm1
6"
3
0:00
�iZZ000A
l/�
•
-
4
7:38
DEPTH TO DATE
GROUNDWATER
16' 7/8/2019
14' 7/15/2019
SITE PLAN
DATE READING
CLOCK
TIME
NET TIME
(MINUTES)
WATER LEVEL
READING
NET DROP
(INCHES)
7/8/2019 1
0:00
-
6"
-
2
6:42
6:42
0"
6"
3
0:00
-
6"
-
4
7:38
7:38
0..
61,
5
0:00
-
6"
-
6
7:42
7:42
0"
6"
7
0:00
-
6"
-
8
7:58
7:58
0"
6"
9
0:00
-
6"
-
10
8:02
8:02
0"
6"
11
0:00
6"
-
12
8:05
8:05
0"
6"
19 PERCOLATION RATE 1.3 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 4 FT. AND 5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES NO
SOILS LOGGED BY: DAVID GARNESS PERCOLATION TEST PERFORMED BY: DAVID GARNESS
COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH.; PERK WAS PERFORMED WITH MOA ONSITE EMPLOYEE TIM ECKLUND OVERSIGHT
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PER OR�/ ED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: �// c/
/ V
t. __ Quanics
GARNESS ENGINEERING GROUP, Ltd AdvancedTreatment System
ENGINEERING SALES CONSULTING
Dealer
June 19, 2019
Municipality of Anchorage
Development Service Department
On-Site Water &Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Proposed Septic Tank Upgrade for Alpine Terrace; Block 1, Lot 10
To whom it may concern:
The subject lot is served by a private well and septic system. Per MOA memorandum, a steel
septic tank over 30 years of age must be physically inspected and/or replaced. Based upon this
fact, we are proposing to install a new septic tank. We are proposing to decommission the
existing septic tank per UPC and install a new IM-1530 infiltrator septic tank. See attached
design drawings for tank location and other MOA requirements.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact us at 337-6179. Thank you for your
assistance.
Sincerely,
Jeffr A. came '.E., M.S.
President
3701 East Tudor Road, Suite 101 *Anchorage,Alaska 99507-1259
Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com
i 1 1
I 1
GEG,Ltd.HAS AN 8 PAGE SPECIFICATION LETTER I
THAT PERTAINS TO THIS DESIGN.BY PROCEEDING NOTE:THE CONTRACTOR SHALL HAVE THE
FORWARD WITH THIS INSTALLATION,THE
ENGINEER,WELL DRILLER,CONTRACTOR AND WELL RADII FLAGGED BY A REGISTEREDI
PROPERTY OWNER AGREE THAT THEY HAVE LAND SURVEYOR PRIOR TO CONSTRUCTION.
READ THESE SPECIFICATIONS AND AGREE TO I
ACCEPT THE TERMS AND CONDITIONS OUTLINED.
CARR;LOT 3A \
TRENCH ORIENTATIONS AND LOCATIONS ARE
UNKOWN;SOUTHEAST PORTION OF ALL THREE
TRENCHES TO BE LOCATED TO CONFIRM 5'
10'UTILITY EASEMENT SEPARATION DISTANCE OF PROPOSED TANK
SOUTHEAST PORTION OF BED TO BE EXPOSED;
INSTALL CLEANOUT AND MT IN SE CORNER
•%••'i•
PROPOSED IM-1530 INFILTRATOR SEPTIC
••• ',..."•••••• ?••':' ....4 TANK;EXISTING SEPTIC TANK TO BE
•! DECOMMISSIONED PER UPC.
�.. • • '• •
•
"...'e•
"�':'' -...7.i.• • SHED
EXISTING MT;INSTALLC/O AND FUNCTIONAL MT •\ •
• • +•f•: :r
i AT BEGINNING OF TRENCH.GEG TO BE .y.
/ PRESENT DURING C/O INSTALLATION •
•; CARPORT o
c•:- O
\ S— 1 :r r_
F�<� :•::•' \ EXISTING4 GRAVEL m
\ BEDROOM HOUSE ••`y DRIVEWAY z
{J.
GRAVEL ';%• �' ;
DRIVEWAY ' •`4 '�I. :..
..•.., .•; :.. .. • : ?: ..:•�: ..+' SHED
•4 `'~ .
il(\1
•' .4% �J DRIVEWAY :.•+ ".*•••• •:.•••••"./...;. ,• . '"-,-.
"•''• }}hht SCALE:
1"=40'
.616\\\ . ..
..x
�j•
GARNESS ENGINEERING GROUP, Ltd ; •
ENGINEERING SALES.CONSULTING or
3701 E.TUDOR ROAD,SUITE 101•ANCHORAGE.AK 99507•PHONE(907)337.6179•FAX(907)338-3246•WEBSITE:www.gemessengneering.00m • • ;
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ,0 ••/•• I: '. Garne s /W:
KELLY POSTON 907-240-2319 1 OF 1 ts�J, CE-\.53 *=
PROJECT/LEGAL DESCRIPTION: DRAWN BY:
ALPINE TERRACE; BLOCK 1, LOT 10 D.J.G. ., IFI ...4./242. �(' �P�,.'•.
TYPE OF WORK: DATE: LICENSE.4
,. ESS
JJ\� ��•
DESIGN OF SEPTIC TANK UPGRADE 6/20/2019 #AECC884 ������
! /IUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME IPHONE
MAILING ADDRESS
LEGAL DESCfllPTION
LOGATION NO. OF BEDROOMS--
JWeU I Absorption area Dwelling PERMIT NO.
~ DISTANCE TO: i ~.~ [~ t
~< Manufacturer ~ r~_ ~r M~te~ 7~ , No. of compartments ~
~ Liq. capamty in g~lons IF HOmE,DE: Inside length Widt~ Liquid depth ~
~ ~ Well Dwelling PERMIT NO.
~ ~ Z DISTANGE TO:
O ~ ~ Manufacturer Material Liquid capacitV in gallons
= Well Foundation Nearest lot line PERMIT NO.
DISTANCE
TO:
~ ~ ~o. of lines ken,th of each line Total length of lines Trench ~idth ~istance between lines
inches
~ ~ Top of tile to finish ~rade Material beneath tile Total effective absorotion area
~ inches
Length Width Depth PERMIT NO,
~ ~ Type of crib Crib diameter Crib depth Total effective absorption area
~ Well Building foundation Nearest lot line
~ DISTANCE TO:
~ Class Depth Driller Distance to lot line PERMIT NO.
~ DISTANCE TO: Building foundation Sewer line Septic tank ~ (~: (~.~ Absorption area(s)
OTHER
.~P. MATEmALS ~ NJ~
SOIL TEST RATING
INSTALLER
REMARKS
()
72-013 (Rev. 3/78)
GRE '-:R ANCHORAGE AREA BO', IGH
Del)lrtment of Environment Quality
3500 Tudor RoKI
Anchor~. Alaska 99S07
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCATION
MAILING Al)DRESS ?'f/~- /J~/ g-.2~'7 ~ ,,.
SEPTIC TANI~ ,~t~' H
NUMBER OF
WM ~ ~ INSI~ WIDTH ~ LIQU~ ~ ~ , LI~ CN~I
DIAGRAM OF SYSTEM
/ ·
· b/eL/-
DAT~~ APPROVED
GRE,_.ER ANCHOragE AREA Bo~ugh
DEPARTMENT OF ENVIRONMENTAL QUALITY
:3500 TUDOR ROAD POUCH 6-6§O
ANCHORAGE, ALASKA 99502
TELEPHONE 279-8686
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
. ~_ ., / MAILING
INSTALLATION OF: SEPTIC TANK ~ SEEPAGE PiT
PERMIT NO. -
PHONE
DRAIN FIELD
OTHER
DRAIN FIELD
SEPTIC TANK TO SEEPAGE PiT WALL I
SEPTIC TANK . SEEPAGE PIT ,
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK
DRAIN FIELD
WATER MAIN TO SEPTIC TAN_~K
DRAIN FIELD /~"~/:
SEPTIC TANK, I . SEEPAGE PIT
TO RIVER. LAKE. STREAM.
DRAIN FIELD
SEEPAGE PIT
ALSO CONSIDER AREA WELLS.
SEEPAGE PIT., /~r~
/
, DRAIN FIELD
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION S FEET INTO UNDISTURBED SOIL,
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PiT
FIT'TED WITH AIRTIGHT REMOVABLE CAPS,
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
OR
LICENSED DESIGNER
FOUNDATION TO SEEPAGE PIT
_ _ TYPE
MINIMUM DISTANCES, REQUIREMENT~
FOUNDATION TO SEPTIC TANK '~
/
DIAGRAM OF SYSTEM
I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
DATE~' ~[~ / ¢ 7 ~-~''''DE$CRISED SYSTEM'S IN ACCORDANCE WITH SAID CODE.__ APPLICANT'S SIGNATURE ~'"~L ~"~ 0' ~' J'~~_
PINAI. IN~PEC. TION~ 14 HOUR NOTICE RIQUlRED. B&CKPILLING OF' ANY SYSTEM WITHOUT FINAl., INSPECTION IBY 'rHIE
HEALTN DWPARTMENT AUTHORITY ~II.L BE SUBJ~'I=T TO PROSW~UTION.
TO BE IN T L'~
S A LED BY
/
~'~--)'~l~/ ~ / NOTE: THIS PERMIT IS NOT VALID WITHOUT ~,OIL TEST
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
GRE,,,, ,.-:R ANCHORAGE AREA BOF.<,...JGH
DEPARTMENT OF ENVIRONMENTAL QUALITY
350(') TUL')OR ROAD F'C}UCH 6-650
ArqCHO~AGE ALASKA 99502
TELEPHOTO[ 279-8686
PERMIT NO,
N^ME OF ^PPL~CANT
INSTALLATION LOCATION
PHONE
INSTALLATION OF: SEPTIC TANK ~ SEEPAGE PIT DRAIN FIELD OTHER
SOIL TEST RESULTS ~P ~//~"; ~ NOTE~ THI~ PERMIT IS NOT VALID WITHOUT ~IL ~ST
PFRMTT VAI ID ~NF YFAR
FINAL INSPEGTION~ 24 HOUR NOTI~ REGUIRED. BACKFILLING OF ANY ~Y~M WITHOUT FINAL IN~E~TION BY THE
H~A~TH D~PARTM~NT AUTHORI~ WILL BE ~U~J~CT TO PROSECUTION.
SEPTIC TANK SIZE /('~¢)L¢~ TYPE~te~-] Ol' ct~ncTR[eSEEPAGE AREA SIZE TYPE
MINIMUM DIBTANCES, REQUIREMENTS
5 ft.
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGE PIT 20 f~e DRAIN FIELD 10
SEPTIC TANK TO SEEPAGE PIT WALL [.5
SEPTIC TANK 5 fg, , SEEPAGE PIT 20 fi' . DRAIN FIELD TO NEAREST LOT LINE.
WELL TO SE.lC TANK~'~ ~ ' SEEPAGE Pli /~ '
WATER MAIN TO SEPTIC TANK l0 ft~ . SEEPAGE PIT [0
DRAIN FIELD [0 rte
SEPTIC TANK, 25 ft. SEEPAGE PIT 100 fi,, Oe*,N F,ELD 50 ft.
TO RIVER, LAKE. STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF .........
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL.
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
OR ( ~"
LICENSED DESIGNER
DIAGRAM OF SYSTEM
4" CAf:T iRON SIPUON
· $~PTIC PIPC .lT. AIRTIGHT CRIB
IMJt: / CAPS ~ .
,.,.~".=,: ....... - ........... . ...... n .....
CAS~ ],o, I.'::":'.q- .... 1.:;'::.. I
· JaTo I;..:{'VL-: ~ :.
' ' ~RAVEL
C J required Ml~n~ver line crosses (CRIB 4~ HINI~U~ A~0~'[ ~ATER:
undcr dr~ve~'ay. IABLE)
i ' -~ Grade; ;.'.per ICO'
/ or 1/4" p r foot
! except 10' prec~udin.
HOUSE ! tank & fha. s~uld
not exceed
/ 6~ per 100 on f)at
J terrains.
(,AST ]~rflfh .-~ /SEPTIC
PI?/ 5' ~ ...... /~TAN~ /
Ir;To u~- I I~1 4 ]r~cH
~ISTL~E~ ~ [ CAST IRO~ SIPHON PIPE
I CERTIFY THAT IAM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 2S-68 AND THAT THE ABOVE
DATE __ ' ?' ? APPLICANT'S SIGNATURE ~'
EATER ANCHNRAGE AREA BOROI,
DEPARTMENT OF ENVIRONMENTAL QUALITY
3500 TUDOR ROAD
ANCHORAGE, ALASKA 99502
CASE #
Performed For Joh~ /~-mm~-o~ Date Performed ?/29/72
Lemal Description: Lot 10 Block 1 Subdivision ~lme Terrace
This Form Reports Soils Log x Percolation Test
qeoth
Feet
5
6__
7--
8
9__
Soil Characteristics
Well graded sand & gravel
(~2~)
Was Ground Water Encountered?.^
I~ Yes, At what Depth?
Readinq
Date
Gross Time
Net Time
Depth to H20
Net Drool
Percolation Rate Hinute
Proposed Installation: Seeoaae Pit x Drain Field
Deoth of Inlet Deoth To Bottom Of Pit Or Trench
C~M!~ENTS· 125 f~ sqper~6'~;~t~.
Data Certified By:
Date ·
$850 Runarnuck Place
ANCHORAGE, ALASKA 99502
' 3~.9692
Mr.. Gary Seese
409 Taylor Str.eet
Anahorage, Alaska
PLEASE DETACH AND RETURN WITH YOUR REMITTANCE
DATE
June 21, 1978
NUMBER
Hillside Drive.
5/23
tank
lot
5/24
6/12
6/17
CHARGES AND CREDITS BALANCE
BALANCE FORWARD ~ (2500 00)
8 hrs. Drott 40 move septic system & dig for new
8 hrs. labor
3 hrs..Drott 40 dig on basement
B hrs';, labor
46 ft. sew. er pipe 1-22½ & 1-45 degree
Septic. Tank
3½ hrs. truck pick up tank deliver &'move 850 to
3 hrs. 850 dozer push out hole
8 hrs. Drott 40 dig out fdtn. & driveway
8 hrs. labor
7 hrs. truck haul off
1 hr. truck move loader to lot
3 hrs. loader backfilling
5½ hrs. dozer baokfill
5 hrs. Dr-ott 40 complete sewer service
5 hrs.. labor
110 ft. sewer .pipe
60 ft. perforated pipe
4½ hrs..dozer backfill drain ditch & grade
i id. washed rock
Ziegler Excavating Company
Thank You
680 00
180 00
255 00
67 50
ll7 59
695 00
136 50
150 O0
680 00
180 O0
27B O0
39 O0
165 00
247 50
425 00
112 50
222 20
75 00
202 50
!39 00
$2497~ 29
PAY LAST AMOUNT
IN THIS COLUMN
Ge
Municipality of Anchorage �.".
-
On -Site Water and Wastewater Program
(907)343-7904 5 'A F E T Y
Certificate of On -Site Systems Approval .
Parcel 1.D.015-243-34 Expiration Date:
1. GENERAL INFORMATION:
Complete legal description ALPINE TERRACE; BLOCK 1 LOT 10
Location (site address) 11601 HILLSIDE DRIVE *ANCHORAGE, 99507
Current Property owner(s) KELLY POSTON Day phone 240-2319
Mailing address
Real Estate Agent BETH SIMPSON Day phone
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well; ® Individual
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community FJ
Public Water System ❑ Public Sewer ❑
WaiverNariance request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ Jed Waiver Fee ' $` `
Date of Payment o1.jILIbpbAo Date of Payment
Receipt Number 0`53 Receipt Number
COSA# Q�Gy1053-
VVaiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179
Address: 3701 East Tudor Road Suite 101- Anchorage, Alaska 99507
Engineer's Printed Name: Jeffrey A. Garness Date: 7i�1 ilZ�
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system
in accordance with the guidelines and regulations established by the Municipality of Anchorage and
industry practices. The reported results describe the condition of the system/s on the date/s of the
evaluation. Separation distances were measured to readily identifiable features. Hidden defects or
encroachments may exist that were not identified during the evaluation. The operational life of all wells
and septic systems depend upon a variety of variables, including but not limited to, soil conditions,
groundwater levels (that may fluctuate during the year), quality of construction (materials and
workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and
are outside the control of GEG. Satisfactory test results do not guarantee future performance of the
system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of
the well or septic system. GEG makes no representation whether an alternative well or septic system
can be installed on the property in the event either of the current systems fail to perform adequately in
the future. The content of this report is for the sole benefit of the person/party that retained GEG to
perform the evaluation. Reliance upon the information provided in this report by any other person or
party (including subsequent property purchasers) is not authorized, nor will it confer any legal right
whatsoever.
6. DSD SIGNATURE
0 System #1 Approved for Y__ bedrooms
System #2 Approved for
Disapproved
Conditional approval for
bedrooms
bedrooms, with the foll
OF
T*�
.... . ....... ...........
f A. G ness•:
�a
49, • •, CE- •' � �
0os cG
e -2�.)31:�b
4�Pa P� o f e s slo'°ao
��00000��
OF
OIC -SITE
WATER AND
> silk R`V
STERlS.m
moi, n
9'
�)tP1tP11�
By: '�, tom/ �"' Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory '� fW
Arsenic Advi4ory'�`
Other
c <.. ,.
COSA Checklist
Legal Description: ALPINE TERRACE; BLOCK 1, LOT 0
If more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA I *PER 1972 INSPECTION REPORT l
❑ Well log is filed with Onsite (or attached)
Date drilled 1172(?)
Total depth *47 ft
Cased to LINK ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground)12+ in.
Date of flow test for COSA 6114/19
Static water level at beginning of test 12.3 ft.
Comments
B. TANK DATA
Age of tank(s) NEW years
Tank type/material HDPE
Measured operating fluid level in septic tank -
0 Standpipes/foundation cleanout per record drawing
Date of pumping N/A
'.D. ABSORPTION FIELD DATA __ -
Which system tested (date installed)
0 ALL standpipes present per record drawing
Total measured depth from grade 8.3 ft (max)
Measured depth to pipe invert from grade 3.1 ft (min)
❑ N/A — pressurized field
Al Monitor tubes go to bottom of effective. If not, state
depth into effective
❑® Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced N/A gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
Parcel ID: 015-243-34
Structure served by this system
Well production at time of test 6.2+ gpm
Water storage tank volume N/A gallons
Well disinfected for coliform test? ❑ Yes ❑ Nc
[JQ16—oliform bacteria is Negative
Nitrate 3,5 V mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L rsenic less than MRL (ND)
Collected by GEG, LTD
Date of Sample 2/5120
C. LIFT STATION
❑ Required maintenance
Age of lift station
Lift station mate
Comme .
Adequacy test date N/A
Results ❑✓ Pass For 4 bedrooms
Fluid depth prior to test - in
Water added - gal
New depth - in
Elapsed time - min
Final fluid depth - in
Absorption rate - gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date -
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
Yes
if No
Community Sewer Manhole/Cleanout > 100'
❑✓ Yes
if No
ft
✓❑ Yes
if No
Neighboring Tank > 100' 0 Yes
if No
ft
Private Sewer/Septic Line > 25' Q Yes
if No
Absorption Field on Lot > 100' E] Yes
if No
ft
Holding Tank > 100' Yes
if No
Neighboring Absorption Fields > 100'
Animal Containment > 50' Yes
if No
0 Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' 21 Yes
if No
ft
R] Yes
if No
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10' ❑✓ Yes if No ft Surface Water > 100'
ft
ft
ft
ft
M
❑✓ Yes if No ft
Property Line > 5'✓❑
Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
✓❑ Yes
if No
ft
Private Wells > 100'✓❑ Yes if No
Water Main > 10'
✓❑ Yes
if No
ft
Community Wells > 200'✓❑ Yes if No
Water Service Line > 10'
❑✓ Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' ✓❑ Yes if No ft If absorption field is under driveway comment below
Property Line > 10'
0 Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
0 Yes
if No
ft
Private Wells > 100' 0 Yes if No
Water Service Line > 10'
0 Yes
if No
ft
Community Wells > 200' 0 Yes if No
Surface Water > 100'
❑ Yes
if No
*80'+ ft
F. ENGINEER'S COMMENTS
*WR#OSV191059
G. ENGINEER'S CERTIFICATION
l certify that 1 have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
0
9
�Oe fr A. Go ness.••
Q�
(�E-79 � �
Z11, :_-
LD �Ao
0
�Dea
or f e s"'00
#AECC884
ft
ft
ft
ft
c
r:
49 49 THW .'.7
D O
N� SHANE A. HOLT .' G
�pe LS -6914 v O
44ap... �a v�
essio�a�
S 89 58' E 2 10. 00
........... .. ,%, GRAVEL PARKING AREA
S a{
-------------------------------
`G
�I
00 00 �O
1
01.1 K CARP117
I O
m:
ry.
1
t '.3
E FPM���SE
INOL ENO
UD<LK
49.8
WELL �
j 1v1
ASPHALT .^DRIVEWAY
Al 89 58' E 2 10. 00
AS-BU/LTSURVEY 1 " =30'
NO CORNERS SET THIS DATE
SURVEY ORDLFREO SK
LIAR !'.^.LDEN C
iKELLER .h lLUfi:.fS
I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY
OF THE FOLLOWING DESCRIBED PROPERTY
LOT 10, BLOCK 1, ALPINE TERRACE SUB.
ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE
VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN
THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS
CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS EXIST OTHER THAN NOTED.
NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES. DATED AT ANCHORAGE ALASKA THIS 6 TH DAY OF
EASEMENTS OF RECORD, OTHER THAN THOSE APPEARING ON THE RECORD PLAT , ARE NOT SHOWN —
HEREON ( UNLESS INDICATED) _AUGUST , 2019
NOTE: FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE
PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS. HOLTLANDSURVEYING
ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE. 9309 GROVER DRIVE
ANCHORAGE,AK 99507
12505, FE 162-40, 198-67 907223.8615
Parcel I.D. #
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
(907) 343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILLY DWELLING
015-243-34
1. GENERAL INFORMATION
complete legal descriPtion
ALPINE TERRACE SUBDIVISION:
LOT 10. BLOCK 11
Location (site address or directions)
11601 HILLSIDE DRIVE
ANCHORAGE AK, 99516
Property owner VICKI AND LELAND CliO
Mailing address 11601 HILLSIDE DRIVE
Lending agency.
Mailing address
Agent REAGAN RUSSEY - REAL'P¢ EXECUTIVES
Address
Day phone` (907) 545'1283
Day phone
Day phone (907) 244-0225
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual well xx
Community well
Public water
NOTE: If community well system, provide written qonfirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding Tank
Community on-site
Public sewer
NOTE:
xx
If community wastewater system, provide written confirmation from State ADEC
lng to th~ legality and status of system.
72q325 (Rev. 1191) Front MOA#21 Computer Version
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown bel°w, I verity that my
investigation of this Health Authority Approval application shows that the on-site water supply and/or
wastawater disposal system is safe, functional and adequate for the number of bedrooms and type of
structure indicated herein. I further verity that based on the information obtained from the Municipality of
Anchorage files and from my investigatior{ and inspection, the on-site water supply and/or wastewater
disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect
on the date of this !nspection.
NameofFirm ALASKA WATER & WASTEWATER CONSULTANTS, INC. Phone (907)337-6179
Address 6901 DEBARR ROAD, SUITE 2B ANCHORAGE. ALASKA 99504 :. / /
Date
Engineer's signature
ALASKA WATER & WASTEWATER
CONSULTANTS, !NC. SHALL BE
PAID $250:00 AT, OR
PRIOR TO, CLOSING FOR THE
ENGINEERING SERVICES PROVIDED.
6. DHHS SIGNATURE
X Approved for 4
Disapproved
Conditional approval for
bedrooms
bedrooms, with the following stipulations:
Additional Comments
Date
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of
homes and their lending institutions in order to satisty certain federal and state requirements. Employees of
DHHS do not conduct inspections or analyze data before a certificate is isSUed. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
72-025 (Rev. 1/91) Back MOA 1/21 Computer Version
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
Environmental Services Division
825 "L" Street, Rm 502 Anchorage, Alaska 99501 (907) 343-4744
Health Authority Approval Checklist
Legal Description: ALPINE TERRACE; LOT 10, BLOCK 1 Parcel I.D.:
015-245-34
A. WELL DATA
Well Type~ PRIVATE If A, B, or C, attach ADEC letter. ADEC water system number
LOg present (Y/N) NO Date completed 1972
Total depth 47' (PER 1972 AS-BUILT) Cased to ¢0% Casing height (above ground)
N/A
2`3"
Sanitary seal (Y/N) YES
Wires pmperiy protected (Y/N)
YES
Date of test
Static Water level
Well production
FROM WELL LOG
AT INSPECTION
10/29/99
25'
g.p.m. 2.87 g.p.m.
WATER SAMPLE RESULTS:
Coliform ~
Date of sample:
`3/8/2000
Nitrate
_~, ~'~ /"~C~ /.~., Other bacteria.
Collected by: A.W.W.C., INC.
B. SEPTIC/HOLDING TANK DATA
Date installed 4-/78 Tank size
Foundation cleanout (Y/N).
Date of Pumping 10/29/99
C. ABSORPTION FIELD DATA
Date installed 8/72
YES Depression (y/N); NO
Pumper NORTHLAND PUMPING
1500 Number of Compartments 2 Cleanouts (y/N) YES
High water alarm (Y/N) N/A
Soil rating (g.p.d./ff2 or fl2/bdrm) 125
* WATER DID NOT BACK UP J
INTO THE SEPTIC TANK. NOJ
CLEAN-OUTS IN TRENCHES.
SEE A1TACHED LETTER.
SHALLOW
System type DRAINFIELB
Length 11.3' .Width 4' Gravel thickness below pipe 0.5' Total depth 6.7' BGL
Effective absorption area
Date of adequacy test 10/29/99 Results (Pass/Fail) PASS For
Fluid depth in absorption field before test (in.); 0 Immediately after 644-
Fluid depth 0 (ins) Minutes later: 95 Absorption rate =
452 SQ Fl' Monitoring Tube present (Y/N) YES Depression over field (Y/N) NO
4 Bedrooms
gal. water added (in.): 19.5'
600+
Peroxide treatment (past 12 months) (Y/N) NONE KNOWN If yes, give date
72-026 (Rev. 3196) ComputerVerslon
D. LIFT STATION
Date installed ~
Manhole/Access [Y/N) ~P~m~on" level at*
High water alarm level..e~ .*Datum
"Pump off' level at*
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic/holding tank on lot
Absorption field on lot
Public sewer main
Sewer/septic service line
100'+
100'+
N/A
25'+
On adjacent lots 100'+
On adjacent lots 100'+
Public sewer manhole/cleanout
Lift station
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Foundation 7' TO CO Property line 5'+
Water main/service line 10'+ Surface water/drainage *85'
SEPARATION DISTANCES FROM ABSORPTION FIELD ON LOT TO:
Property line 10% Building foundation 10'+
*65'
N/A
**36' PER ORIGINAL INSPECTION.
UNKNOWN AFTER UPGRADE.
Absorption field
Wells on adjacent lots
* SEE WAIVER LETTER
(AUGUST 26, 1995)
Surface water
Curtain drain
F. ENGINEER'S/~I
I certify that I/ha~
of Munic/pal/rec~
with MOA I~AA
Signature ~
Engineer's Naml
Date
Water main/service line
Driveway, parking/vehicle storage area
Wells on adjacent lots 100'+
~ field inspections and review
,e systems are in conformance
~t on this date.
*'51'+
JEFFREY A. GARNESS
100'+
10'+
10'+
HAA Fee $
Date of Payment
Receipt Number
72-026 (Rev. 3/96)* Computer Version
Waiver Fee $
Date of Payment
Receipt Number
Alaska Water & Wastewat :r Consultants, Inc.
6901 Debarr Road, Suite 2-B - Am orage ~ Alaska 99504
Phone (907) 337.6179 ~ Fan 907) 338-3246
Consulting Engi~ ers
November 9, 1999
Municipality of Anchorage
Department of Health & Human Services
Division of Environmental Services
On-Site Services Section
P.O. Box 196650
Anchorage, Alaska 99519-6650
Subject: Septic System Test at Lot 10, Bk 1, Alpine ierrace S/D.
To whom it may concern:
Attached is the HAA "brown sheet" for the subject pro ,erty. It should be noted that there are no
clean-outs in the trenches and only one monitoring tul ':. The effective depth of the system is 6
inches per the 1972 inspection report. Water was intr ~duced into the monitoring tube (the only
pipe available) at a rate of 2.87 gpm for 231 minutes. 'l'his caused the liquid level to rise in the
MT to 19.5 inches. It is assumed that the majority of i!~e rise was due to a build-up of hydraulic
head in the monitoring tube and that the liquid level ':~'~ the trenches was not 19.5 inches. The
monitoring tube was dry 95 minutes after we stopl d introducing water. If you have any
questions, please call us 337-6179.
h.s.
MUNICIPALITY Of ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6660
343-4744
Parcel I.D. #
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
015-243'-34;
1. GENERAL INFORMATION
Complete legal description
Lot 10; Block 1; Alpine Terrace Subdivision
Location (site address or directions)
Property owner
Mailing address
Lending agency
Mailin. g address
Agent
Address
11601 Hillside Drive
Anchoraqe~ AK
Vicki & Leland Cho Dayph0ne
345-1283
11601 Hillside Drive Anchoraqe, AK 99516
Day phone
Reaqan Russey/~k--~l~i-k~t .
Day phone
244-0225
Unless otherwise requested, HAA will be held for pickup.
4
NUMBER OF BEDROOMS:
TYPE OF WATER SUPPLY:
××
Individual well
Community well
Public water
NOTE:
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL.-
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE:
XX
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025(Ray. I/91) Front MOA~21
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect~stJ~~ (~c~is inspection.
Name of Firm W~$fm~v; , Cnn~n~t~rits; /n~ Phone
Address ~0~[ ~r/~FSuit! 2B
ncnee seignature Date
Wastewater Consultants, Inc.
Shall be PAID ,$ IlOO~'-
or prior to, closing for tho
Engineerin~ So.ices Provided.
6. DHHS SIGNATURE
X
A?proved for
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
Additional Comments
Date ///-/¢ -//
The MuniciPality of Anchorage Department of Health and Human Services (DHt4S) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to pumhasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work,
Municipality of Anchorage NOV 0
DEPARTMENT OF HEALTH & HUMAN SERVlC,~,_,.
Environmental Services Division ENViRONM~-N'~A~ S~kv,L.~.S Di
825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744
Health Authority Approval Checklist
Legal Description: ~ PlNF TFRRA~F'; I OT 10. BLOCK 1 Parcel I.D.:
-O15-243-34
A. WELL DATA
Well type PRIVATF' If A, B, or C, attach ADEC letter. ADEC water system number
N/A
Log present (Y/N) NO Date completed
Total depth ~-7' (PER 1972 AS-BUiLT) Cased to
1972
Casing height (above ground) 25"
Sanitary seal (Y/N)
YES Wires properly protected (Y/N) YES
Date of test
Static water level
Well production
WATER SAMPLE RESULTS:
FROM WELL LOG AT INSPECTION
J g.p.m. 2 87
g.p.m.
Coliform ~3 Nitrate
3.05 mq/L Other bacteria
Date of sample:
10/29/99 Collected by: A.W.W.C., INC.
B. SEPTIC/HOLDING TANK DATA
Date installed 4/7~ Tank size
Foundation cleanout (Y/N) YES
1500 Number of Compartments 2 Cleanouts (Y/N).__
Depression (Y/N) NO High water alarm (Y/N) N/A
YES
Date of Pumping 10/29/99
C. ABSORPTION FIELD DATA
Date installed Fi/7?
Pumper NORTHLAND
I
* WATER DID NOT BACK UP INTO THE SEPTIC TANK. J
NO CLEAN-OUTS IN TRENCHES.
1
Soil rating (g.p.d./ft2 or ff2/bdrm) 1 ?5 System type
SHALLOW
DRAINFIELD
Length 11 ~' Width
4' Gravel thickness below pipe R.5' Total depth 6.7' BGL
Effective absorption area 452 SO FT Monitoring Tube present (y/N) YFS Depression over field (y/N) NO
Date of adequacy test 10/29/99 Results (Pass/Fail) PASS For
bedrooms
Fluid depth in absorption field before test (in.);
Fluid depth 0 (ins) Minutes later:
0 Immediately after 64-~ga1. water added (in.): 19.5'
95 Absorption rate = 600+ ~.p.d.
Peroxide treatment (past 12 months) (y/N) NONE KNnWN If yes, give date
72-026 (Rev. 3/96)*
D. LIFT STATION ., _ ~
Date installed ~
..~ Manhole/Access (Y/N). ~t* "Pump off" level at*
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic/holding tank on lot 100'+ On adjacent lots
Absorption field on lot 100'+ On adjacent lots
Public sewer main N/A Public sewer manhole/cleanout
Sewer/septic service line 25'+ Lift station
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO:
Foundation 7' TO CO Property line 10'+ Absorption field
Water main/service line 25'+ Surface water/drainage ~85' Wells on adjacent lots
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO:
10'+
50'+ Building foundation
Property line
Surface water
Curtain drain
100'+
100'+
N/^
N/A
*'51 '+
100'+
25'+
Water main/service line
30'+ TO CARPORT
* 65' Driveway, parking/vehicle storage area
100'+
'5' - 10' Wells on adjacent lots
F. ENGINEER'S CERTIFICATION
If
A. GARNESS
Date
HAA Fee $.
Date of Payment
Receipt Number
72-026 (Rev, 3/96)*
Waiver Fee $
Date of Payment
Receipt Number
Alaska Water & Wastewater Consultants, Inc.
6901 Debarr Road, Suite 2-B - Anchorage - Alaska 99504
Phone (907) 337-6179 ~ Fax (907) 338-3246
Consulting Engineers
November 9, 1999
Municipality of Anchorage
Department of Health & Human Services
Division of Environmental Services
On-Site Services Section
P.O. Box 196650
Anchorage, Alaska 99519-6650
Subject: Septic System Test at Lot 10, Bk 1, Alpine Terrace S/D.
To whom it may concern:
Attached is the HAA "brown sheet" for the subject property. It should be noted that there are no
clean-outs in the trenches and only one monitoring tube. The effective depth of the system is 6
inches per the 1972 inspection report. Water was introduced into the monitoring tube (the only
pipe available) at a rate of 2.87 gpm for 231 minutes. This caused the liquid level to rise in the
MT to 19.5 inches. It is assumed that the majority of the rise was due to a build-up of hydraulic
head in the monitoring tube and that the liquid level in the trenches was not 19.5 inches. The
monitoring tube was dry 95 minutes a~er we stopped introducing water. If you have any
questions, please call us !: 337-6179.
S' ely,l~
me ,P.E., .S.
NOV 09 1999
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
Parcel I.D. #
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
GENERAL INFORMATION
Completelegaldescription _Z.o'/-(0/ ~/c,c/~ .~'~ ,,4/~,,,~ 7-'¢r,",~¢e -~/~
Location (site address or directions) II ~'o ! /-/-~ lis/c.~'e ~r't u ~.
Property owner
Mailing address
Lending agency
Mailing address
Day phone '~.5'7 -
Day phone
Agent .~,.~jc~,o d'~z~/~, b~l( ) "~O01 R¢-.~I I~..s~/"~_
Address ~gO0 P~/~I;
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS:
Day phone '~.'7~' - ~ /
TYPE OF WATER SUPPLY:
Individual well
Community well
Public water
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. 1/91) Front MOA #21
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection, u./~,~,,,r
Phone
Name of Firm
Address
engineer's signature
DHHS SIGNATURE
/~, Approved for
Date ~7-~,
bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
Additional Comments
Date ~ -2 ~- ~'~
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-O25 (Rev. 1/91) Back MOA#21
Municipality of Anchorage
Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: LoT I0 1~_1< [, r~L?//,l{ 7£/~,~ACE Parcel I.D.
A. Well Data
Well type
Log present (Y/N)
Total depth
Sanitary seal (Y/N)
Date of test
Static water level
Well flow
Pump level1
¥
If A, B, or C, attach ADEC letter. ADEC water system number
Date completed l 'J-/2 Driller
I
Cased to ~'~ H '7 Casing height
Wires properly protected (Y/N) Y
FROM WELL LOG
AT INSPECTION
MUNiCIPALiTY OF ANCHORAGE
Et,,W'IRONMENTAL SERVICES DIVISION
1995
g.p.m.
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot
Absorption field on lot
Public sewer main N.
Sewer service line 12 o
; On adjacent lots '>./o o
; On adjacent lots ~. /o o
Public sewer manhole/cleanout N./},
Petroleum tank NONE
WATER SAMPLE RESULTS:
Coliform 0 ¢o! //Or2 r,', ~
Date of sample: 7J-//~q :~
Nitrate
I.-II ~,j~' /"-~ Other bacteria
Collected by: ~-/_,4 T'rO? TECfl
B. SEPTIC/HOLDING TANK DATA
Date installed
Cleanouts (Y/N)
High water alarm (Y/N)
Date of pumping
Foundation cleanout (Y/N)
Tank size I $ o O G 4z. Compartments 2
7' Depression (Y/N)
Alarm tested (Y/N) I'q,~ ·
Pumper /
N
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot 12 o On adjacent lots
To property line c/5' ' Absorption field
Surfacewater/drainage ~ ~'5" (_£~(~
Foundation '7
Water main/service line
72-026 (3/93)* Front CONTINUED ON BACK PAGE
C. LIFT STATION
Date installed
Manufacturer
Size in gallons
Vent (Y/N) "Pump on" level at
High water alarm level
Meets MOA electrical codes (Y/N)
Manhole/Access (Y/N)
"Pump off" Level at
Cycles tested
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot
On adjacent lots
Surface water
D. ABSORPTION FIELD DATA
Date installed ~/72
Length I 13 ~ Width
Total absorption area ~.52_
Date of adequacy test
Water level in absorption field before test
Peroxide treatment (past 12 months) (Y/N)
Soil rating (GPD/FF)
Gravel thickness
Cleanout present (Y/N)
Results (pass/fail) ~',~5 $
~'PD/F~~ System type
Total depth
Depression over field (Y/N)
for
After test
If yes, give date
N o N~- k'No
Bedrooms
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot I oo' On adjacent lots '~/oo ' Property line
I
To building foundation [ '7, To existing or abandoned system on lot
On adjacent lots ~>/oo ' Cutbank N. A · water maiwsewi~ line
Sudace water ~ d3" ~ c~F ~~ Driveway, parkin~ehicle storage area
Cu~aindrain 0~1~ h'~ ~ ~ ~,'~ ~ ~o' o~ ~;~ ~ -
E. ENGINEER'S CERTIFICATION
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signature J~ ~ ~ - *
Waiver Fee $
HAA Fee $ /~70) o o
Date of Payment ~-~0- ~)-%
Receipt Number c~4c~ ~
Date of Payment
Receipt Number
72-026 (3/93)* Back
Munk ality of Anch ra e
Department of Health and Human Services
Tom Fink, 825 "L" Street
Mayor P.O, Box 196650 Anchorage, Alaska 99519-6650
343-4744
August 26, 1993
Ted Moore, P.E.
Flattop Technical Services
14530 Echo Street
Anchorage, Alaska 99516
Subject: Waiver Request for Lot 10 Block 1 Alpine Terrace S/D
Waiver Request #WR930043, PID #015-243-34, HA930412
Dear Mr. Moore:
Your request for a waiver(s) of the required 100 foot horizontal
separation of a septic system to the surface water has been
approved. The approved separation distance(s) are 65 feet.
This waiver approval applies to the existing septic system to
surface water separation only. Any future upgrade to the septic
system will require all separation distances be met or another
approval from this department. Should the operation of the
subject wastewater disposal system cause any contamination or
degradation of the subject surface water, this waiver will
become void.
Sincerely,
Daniel J. Roth
Civil Engineer
On-site Services
anager
On-site Services
ljm:#5
MUNICIPALITY OF ANCHORAGL
Department of Health and Human Services
On-site Services Section
Waiver Review Worksheet
WR9 WR930043 PID# 015-243-34 HA# HA930412 Permit 9
Date Received: July 20, 1993
Legal Description: Lot 10 Block 1 Alpine Terrace Subdivision
Engineer: Ted Moore, P.E., Flattop Technical Services
14530 Echo street Anchoraqe, Alaska 99516
Applicant: Randy Taylor
Waiver Requested: Drainfield to surface water of 65 feet (to two road
ditches)
Criteria: 1. Geology: Points:
A. Water Table
B. Soil Sorption
C. Permeability
D. Water Table Gradient
E. Horizontal Separation
TOTAL:
2. Special Conditions:
3. Other:
Waiver is Granted: ~ Waiver is NOT Granted:
List Conditions or Reasons for above:
Rec #: 24948/9077
BY' ~~of Reviewer
Amount: $ 590.00
Date Paid: July 20, 1993
J/VhIV~R /~E~ u£~T
'E
CIVIL & ENVIRONMENTAL ENGINEERING * ENERGY CONSERVATION & ANALYSIS
THEODORE F. MOORE, P.E. ~:Tul~"...,1~, 1993 14530 ECHO ST.
PH: (907) 345-1355 ANCHORAGE, ALASKA 99516
M.O.A. DHHS
P.O. Box 19-6650
Anchorage, AK 99519
Dear Sirs:
By means of this letter we are requesting issuance of a waiver allowing the closest portion of the
existing wastewater disposal system serving the residence on Lot 10, Block 1, Alpine Terrace S/D to be as
close as 65 feet from two roadside ditches, both of which still contain small amounts of surface water. A
site plan and other relevant backup documents are enclosed to assist you in your review of this waiver
request.
According to the as-built inspection report on file at DHHS the original wastewater disposal system
was installed in September of 1972, and consisted of a 1000 gallon septic tank followed by a soil
absorption bed with an effective absorption area of 452 square feet. An inspection report dated April,
1978 documents the fact that a 1500 gallon septic tank had been installed, and approved the system for 4
bedrooms. The system was tested and reapproved for 4 bedrooms in June of 1990. On July 7, 1993 we
conducted adequacy tests of the water supply and wastewater disposal systems serving this lot. Since the
residence had been unoccupied for a couple of weeks prior to our adequacy test, we arranged for a water
truck to pre-soak the system with 3000 gallons of water added through the second compartment of the
septic tank. The monitor tube in the drainfleld was dry at the start of the test, and while the presoak water
was being added at a rapid rate the fluid level in the monitor tube rose a maximum of 19.5 inches. Thirty
f~ve minutes later, after the septic tank had been pumped, the monitor tube was again dry. We then ran
another 724 gallons of water from the well directly into the monitor tube. This caused a maximum fluid
buildup of 30 inches in the monitor tube as the water was being added, but the monitor tube was again dry
1.5 hours after the water had been added. (Since the monitor tube is not plumbed directly into the
horizontal distribution pipe network, we believe that the maximum fluid depth measured in the monitor
tube is not reflective of the actual fluid depth in the field, but rather was a result of the attenuated rate of
flow through the sewer gravel from the monitor tube into the distribution pipe network.) Based on the
demonstrated surge capacity being over 6 times the design daily demand of a 4 bedroom residence, we
concluded on the basis of our test data that the drainfield continues to function adequately for a 4 bedroom
residence.
We conducted a previous adequacy test of this system in June of 1990 in conjunction with an earlier
sale. At that time the presence of a small amount of water in the roadside ditches was also noted, but after
several discussions with DHHS, it was decided that a separation distance waiver to surface water was not
necessary. This decision was based on the assumption that the small flow of water observed in the
roadside ditch would probably not be present during most of the year. The fact that a small flow of
surface water was again found during July of this year means that it now is necessary to go through a
formal waiver process. As was the case at the time of the 1990 adequacy test, the discharge pipe from
the sub-surface driveway drain which passes close to the drainfield was dry at the time of our test.
Because of it's relatively shallow burial depth relative to the drainfield, there does not appear to be cause
for concern over this drain collecting and transporting effluent from the drainfield.
Based on visual observation, we estimated the flow of surface water to be approximately 5 gpm, both
in the westward trending ditch parallel to the north property line and in the the north sloping roadside ditch
along the east side of Hillside Drive. Both ditches are heavily overgrown, and the presence of any water
is not apparent unless one walks in the immediate area. In our opinion, the presence of water in these
ditches is attributable to a shallow water table perched on a relatively impermeable substratum. Surface
water is present in these locations only because deep ditches were cut to improve the runoff characteristics
along Hillside Drive and the driveway accessing Lot 3 of Carr S/D. The ditch depth is sufficient that the
bottoms of the ditches penetrate into the top of the groundwater table. On July 14, 1993 we measured the
elevation of the bottom of the monitor tube in the drainfield to be 12.4 feet higher than the water level in
the ditch midway along the north property line. These measurements indicate that there is more than the
required 4 foot vertical separation between the bottom of the soil absorption system and groundwater.
The exact underground configuration of the soil absorption system serving this lot and the discharge
pipe from the subsurface driveway drain is unknown. The configuration plotted on the site plan is based
on the locations of standpipes coupled with information from DHHS files indicating the lengths of the
various laterals and that the closest drainfield lateral is 100 feet from the well. The 65' separation distance
to the water in the ditch along the north property line is a slightly conservative figure based on the locations
of the system components as plotted on the site plan.
In the event that effluent were to overflow from one of the standpipes as a result of the system being
unable to function adequately, the flow path to surface water would be over 100 feet due to the
northwesterly trending slope of the topography. The potential of effluent daylighting in this manner is
negligible, because it would back up into the residence before this could happen, forcing the property
owner to repair the problem.
In consideration of the above information, it is our opinion that the requested waiver can be safely
granted without concern as to the potential for contamination of the surface water in the roadside ditches by
effluent originating in this wastewater disposal system.
Please give me a call if you have further questions on this analysis.
CC.'
Dr. Randy Taylor
Susan Campbell, 2001 Real Estate
Sincerely,
Ted Moore, P.E.
DITCId
LoT :~
C/t~R SUB.
~ CLE~N OUt~ Su~ - ~v~F~C~
I
o~a '~-.,.
1
1
q BDR~ .. 1
HouSE C~.
~ELL ~
I
2.10'
UT IL IT~t
LoT ~
BI_~ I
~L~INE
?£RRACE
Lot ct BLK I
AL PtNE TERR4c~,latt0P
~- Technical Services
e.-- ..s~,r,~.. "' .... ~:' 14530 Echo Street
~,sT~-~ /~r]chorage, -Alaska 99518
LOT
lO, BLK 1, ALPINE TERRACE
SITE PLAN
--cCFJL£: I"-- .5'0 '
DATE: -7 J q S
NOTE: THIs Is NoT
~u~Vs: YED PLAT.
ALL LOCATIoN~
ARE APPI~ox ~MATE.
A
MUNICIPALITY OF ANCHORAGE
Department of Health & Human Services
DIVISION OF ENVIRONMENTAL SERVICES
343-4744
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF
ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING
1. GENERAL INFORMATION (Must be completed prior to submittal)
(a) Legal Description (include lot, block, subdivision, section, township, range)
Location (address or directions)
II~ool ~ lL~ $1o~ DR
(b) Property owner
Mailing Address
Telephone'(home) 3qS'-3zl.¢ Business
(c) Lending Institution
Mailing Address
Telephone
(d) Real Estate Company and Agent
Address J2~O0 CoRDOCfJ
qqs-o
Telephone 27/~- 2-7(,/
(e) Mail the HAA to the following address: (or check here ~, if hold for pick up.)
List contact person and day phone number below:
2. TYPE OF RESIDENCE
Single-Family~ Number of bedrooms ~
3. WATER SUPPLY
Individual Well 15¢ Community [] Public []
Note: If community well system, must have written confirmation from the Staie Department of Environmental
Conservation attesting to th legality and status.
4. SEWAGE DISPOSAL
On-site J:~ Public [] Community [] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to the legality and status.
72-025 (Rev. 7/88) Page 1 of 2
5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this
Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe,
functional .and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and
State codes, ordinances, and regulations in effect on the date of this inspection.
Name of Firm ~'Z. Pr TTO P "T'E ¢'/~ · ~,"C$ Telephone
Address 1~ 5 3o ECl-fo ST, /~,~cl~ . r~l<
Engineer's Seal
6. DHHS APPROVAL
Approved for/~(/¢-~,~oedrooms by
Approved ~ Disapproved Conditional
Terms of Conditional Approval
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval
cerificated based only upon the representations given in paragraph ,5 above by an independent professional engineer
registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections
or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions
in the professional engineer's work.
72-025 (Rev. 7/88) Back
Page 2 of 2
~ MUNICIPALITY Of ANCHORAGE (MOA)
MUNIC~ALII~.~I. fO Health Authority Approval (HAA)
RAGE CHECKLIST. FEBRUARY 1984
ENVIRONMENt. s DIVISION
N 4 1990
R£C£1V D
A. WELL DATA
Well Classification P[~ I V~TE
343-4744
Legal Description: L
Well Log Present (Y/N) No Date Completed 1972
Total Depth ¥7' Cased to ~ ~'~ Depth of Grouting
Static Water Level ,~ $ /
Casing Height Above Ground ,~, I"
Electrical Wiring in Conduit (Y/N)
/O
Tgli' RAc E'
SEPARATION DISTANCES FROM WELL:
To Septic/Holding Tank on Lot J ~O
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line ~ 100'
To Nearest Sewer Service Line on Lot
; On Adjoining Lots '~/00
1 O0 ' ; On Adjoining Lots ~'
To Nearest Public Sewer Cleanout/Manhole
12o
Water Sample Collected by ~'/. ltl-roe 'T'£cd. ~vc~' ; Date
WaterSampleTestResults ~/tT~$FFtCTORY - 0 CoztFoR~ ///oo
Comments Dc,RiNG ~./El.c. FLOC,,./ TEST O~ G/z't/clO ~TEAb¥
B. SEPTIC/HOLDING TANK DATA
Date Installed Z/'/7~ Size~No. of Compartments '2_
Standpipes (Y/N) yEg Air-tight Caps (Y/N) ¥£$ Foundation Cleanout (Y/N)
Depression over Tank (Y/N)
Pumping/Maintenance Contact on File (Y/N)
Holding Tank High-Water Alarm (Y/N) N/A
!
too
'7 /00 /
18 '71 G,4l
I.E.V'E& To
Date Last Pumped
Temporary Holding Tank Permit (Y/N)
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK:
To Water-Supply Well [ 2. ID To Building Foundation -~. 2 F'RoPt
To Property Line ~JS' ~ To Disposal Field ~ ~ ~
To Water Main/Service Line
To Stream, Pond, Lake or Major Drainage Course
Comments
'TANK ~v'H~C~ W'~r~ C_AR,~ Y cNG
;:;
~EPTIC
014 THE I)t~T6 oF THE "['EST.
72-026 (Rev. 7/88) Front
~)iT¢~ c~o NORTH oF THE'
"T'ms ~$ P'~oc3,~Bz ¥ bRY Mo~T oF THE
Page 1 of 2
'727 '
Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
Pump Set At
Yield ~' 7.g GPM
If A, B, C, D.E.C. Approved (Y/N)
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed I~/'~ 2
Width of Field z~ '
!
Square Feet of Absortion Area
Depression over Field (Y/N) No
Results of Last Adequacy Test
SEPARATION DISTANCE FROM ABSORPTION FIELD:
To Water-Supply Well /OO
17.5-
To Building Foundation
Lot HONE'
To Water Main/Service Line
'/BD$1~ Type of System Design DRAt
Length of Field I I~
I
Depth of Field
Gravel Bed Thickness {o
Statndpipes Present (Y/N)
Date of Last Adequacy Test
To Stream, Pond, Lake, or Major Drainage Course ~ /oo '
To Driveway, Parking Area, or Vehicle Storage Area (¢ ! '
Comments * DdR~NG ~bE4:)uAc¥ TE57/ 5Y'~T6/'4
To Property Line ~O /
To Existing or Abandoned System on
; On Adjoining Lots '~/Oo '
To Cutback (if present)
( 5~£ Coe~m
Date Installed
size in Gallons
"Pump on" Level at
High water Alarm Level at
Tested for
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test.
Meets MOA Electrical Codes (Y/N)
I certify that I have checked, verified, or conformed to all MOA and HAA g~~fect
~ ....... ~2 ~
inspection.
signe
~5' '::': ':' :¢ ~5.~ Engineer's Seal
Date ~n
~o~o~ ~. ,4o0~ .
Receipt No. ~-
Date of Payment
Amount: $
Receipt No.
Waiver Fee: $
Date of Payment
72-026 (Rev. 7/88) Back Page 2 of 2
~INICIPALITY OF ANCHORAGE --
'~EPARTMENT _. HEALTH AND ENVIRONMENTAL .ROTECTION
825 L Street, Anchoraa~, Alaska 99501
264-4720
Date Received: April 19, 1978
#1: Time i;';~ ~ #2: Time #3: Time
Date
Date Date
Insp Insp
REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES
1. Lending Institution Request:
Mailing Address:
2. Property Owner: James H. Patterson
Mailing Address: 3500 La Touche 99504
Phone:
Phone:
274-2252
3. Legal Description: Lot 10 Block 1 Alpine Terrace Subdivision
4:
Single Family Residence: (~
Multiple Family Residence: ( )
Number of Bedrooms: Four
Number of Bedrooms:
5. Well System: Individual well (~ Community/Public System ( )
Permit # Depth of Well
C o n s t r u c t i o n__ __
Well Log on File ( )
Bacterial Analysis ~
Sewage Disposal System: On-site System
Public Utility
Permit # Installed 1972
Installer
Septic Tank Size tOOQ Manufacturer ~C.~-. ~
Absorption Are~~ /~
Soils Rate ~2- Material
7. Distances: Well to Septic Tank
to Absorption Area
to Sewer Line
Nearest Lot line
Absorption Area
to Nearest Lot Line
Page Two '
Department of Health'and Environmental Protection
Request for Approval of Individual Sewer and Water Facilities
Legal Description: Lot 10 Block 1 Alpine Terrace Subdivision
Comments:
Affadavit Attached: ( )
Approved: ~
Disapproved:
Letter Attached: ( )
Date:
Date:
Department Worksheet:
MUNICIPALITY OF ANCHORAGE
//~~""i~'~ 825 L Street, Anchorage, Alaska 99501
~~equest for Approval of Individual Sewer
and
Water
Facilities
Property Owner: James ![. Patters~ TM B
I~.~ouco_e ;.rchora~e: ;lc. 99501,~
Mailing Address: 3500 m ,
Phone: 27A-72%? I
Name of Buyer:
Mailing Address:
Phone:
I.endJ_ng Institution:
Mailing Address:
Phone:
Realtor/Agent:
Mailing Address:
Phone:
5. Legal Description: Lot 10 ]tloe] 1 M?:~e Terr.~ee
Street Location: /'l~!~lde [)rivc
Single Family Residence: (,~
Multiple Family Residence: ( )
3 present
Number of Bedrooms: p~3~Qse tc~d 1
Number of Bedrooms:
Water Supply:. *Individual Well ( )
If Individual Well, well depth
If Community System, name of system
Public/Community System ( )
Sewage Disposal System: *~n-site System (]:~)
If On-site System, date of installation:
Public System ( )
*NOTE:
A well log is required on ALL wells drilled since 6/75.
** If on-site sewer system is over two(2) years old, an adequacy
test is required by this department.
A fee of $25.00 must accompany each request before processing
'can be initiated.
3/77
Apr±l 24, 1978 R&M No. 851519
Mr, James Patterson
3500 LaTouche, Suite 250 '
Anchorage, Alaska 99504
Subject: Adequacy Test on Existing Sanitary Sewer System; Lot 10, Block 1,
Alpine Terrace Subdivision, Anchorage, Alaska
Dear Mr. Patterson:
At your request of April 21, 1978, we conducted a test of the septic system
on the above described property.
During this test the liquid level in the septic tank was monitored as water
was added to the system.
table:
The measurements are summarized in the following
Liquid Level Below Top Total Gallons
Time of Standpipe Added
1:35 6.2 0
1:42 6.2 25
1:46 6.2 50
1:55 6.1 100
2:04 6.1 150
2:13 6.1 200
2:35 6.2 200
The meter used during the test was a Rockwell 5/8" standard water meter which
had previously been calibrated by R&M Consultants, Inc.
If the proposed 4 bedroom residence on the property is to house 8 people, the
average load on the system can be expected to be 600 gallons per day or .41
gallons per minute. During the test, the system accepted 200 gallons in 60
minutes. This indicates an average effluent acceptance rate of approximately
3.4 gallons per minute at the time of the test.
April 24, 1978
Mr. James Patterson
Pa§e -2-
Because the house on the lot is occupied, we assume that the leach field was
at its normal degree of saturation. We can therefore conclude that the
system is disposing of effluent' at an adequate rate for a 4 bedroom resi-
dence.
We appreciate this opportunity to be of service to you. Please contact us if
you have any questions concerning this test or if we can be of additional
service.