Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ALPINE TERRACE BLK 4 LT 6
Alpine Terrace Block 4 Lot 6 #015-243-20 Inspection Re o 1-1-12.doc Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http:/Avww.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP141174 PID Number: 015-243-20 ❑ New ✓❑ Upgrade Name: Max & Ann Fernandez ABSORPTION FIELD ❑✓ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 11825 Circle Dr. Anchorage, AK ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 1.2 GPD/SF 10 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 5 Ft. Gravel depth beneath pipe 5.3 Ft. Subdivision 'Block Lot Alpine Terrace 4 6 Fill added above original grade 0 Ft Gravel length 52.5 Ft Township Range Section Gravel width 2.5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 556.5 Ft2 Ft. Well 102.6 124.1 N/A N/A N/A TANK O Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1250G,1. Surface Water 100+ 100+ N/A ! N/A Material Number of compartments Lot Line 22.7 6.2* N/A N/A Steel 2 NA Foundation 23.6+ 46.2 N/A j N/A LIFT STATION Manufacturer Capacity Gal. Curtain Drain N/A-- N/A N/A N/A Remarks *WR# OSP1411175 Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by - PIPE MATERIAL House to tank Tankto 3034 drainfield Installer A+ Home Services Drainfield 3034 Co/MT 3034 Inspector Pannone Engineering Services BENCH MARK (Assumed elevation) 100ft Inspdates: ec 16' 7/21/2014 - 7/22/2014 Location and description 2w House Finished Floor 3" 7/23/2014 e COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp OF k,gg,��1 Conditional Approval: Date '9*� i* r49 TH eve annorae E 814 Approve Date rrff �A :! Inspection Re o 1-1-12.doc —EXISTING TANK / ABANDONED PER CODE- -- �.� 1250 GAL TANK ((P)P)—,,�' WELL (E) / \ /4 BEDROOM / \ _HOUSE (c FIELD REMOVED AND FILLED WITH CLEAN FILL SEPTIC AREA (E) / IT] /M 4_� , RESERVE DRAIN FIELD (P) ya MT2� 10 LF x2.5"* x 5.0' E.D., 10.O'TD I PRIMARY DRAIN FIELD ! 52.5 LF X 2.5 WIDE, 5.0' - L WELL-. (E) L_ DRIVEWAY w_' CIRCLE DRIVE w�w�3.i°/ I .y SEPTIC AREA (E) COI &,2 �TH1 2 10.0' TD Zi I FC i 7.6 I j 28.2 - 25.4 43.7 T2 33.0 i 49.4 DC01 35.1 51.4 CCO2 36.1 52.1 M 1 54.4 80.8 COI 53.8 80.2 M2 53.3 5 3. 0 CO2 54.8 0 3. 2 NOTES: PANNONE ENG SVC, LLC Date RECORD DRAWINGS P.O. BOX 100217 ANCHORAGE, AK 99510 J �� " �qSj 12/15/201' PHONE (907) 272-8218 FAX (907) 272-8211 /%rj�p !y+�) Scale 50 W. ...... .. .. ..... P.I.D. NO ALPINE TERRACE BLK 4 LOT 6 .. ...... .. .. .. 015-243-20 MAX & ANN FERNANDEZ Steven R81 ennonee� PERMIT NOCE . F•�,, ..� 49 OSP741174 1825 CIRCLE DR _ PLAN ANCHORAGE, AK 99507 '1�tiFaPROFESs1�NP`��'r Sheet 2 of 3 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS AND ATTACHED PES SPECIAL PROVISIONS. 3. SCOPE OF WORK: ABANDONED OLD TANK AND REMOVED PIT. INSTALLED NEW 1250 GAL SEPTIC TANK AND SOIL ABSORPTION SYSTEM. 4. GROUNDWATER WAS ENCOUNTERED AT A DEPTH OF 18 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. NO WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18 FEET BELOW EXISTING GRADE. FILTER FABRIC 4" R PERF PIPE ALPINE TERRACE BLK 4 LOT 6 / F�DRAIN ROCK 6' ABOVE PIPE INV 1250 G SEPTIC TANK DESIGN PARAMETERS PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 4 (600 gpd) TANK SIZE: 1250g SEPTIC PERC RATE = 1.41 MPI SOIL RATING: 1.2 GPD/SF AREA RCD: 500 SF SYS. TYPE: DEEP TRENCH 5.O'ED RF: — MIN LENGTH: 50 LF USED: 52.5 LF X 2.5' WIDE, 5.3' E.D., 10.0' TD TOTAL AREA: 556.5 SF TRENCH SEE DESIGN PROFILE LEGEND W WATER LINE/ WELL RADIUS SS — NEW SEPTIC LBBREVIATIONS CU COPPER DIP DUCTILE IRON PIPE DRAIN ROCK JI TEST HOLE FC FOUNDATION CLEAN OUT T# < 1 B9 J Cn CLEAN OUT N0. m# MONITOR TUBE NO. SECTION RIGID INSULATION DCO DOUBLE CLEAN OUT DV GM/7_34 B! FS FLOW SPLITTER BFG - BELOW FINISH GRADE -160 E 826 ORIGINAL GRADE FG FINISH GRADE TS&V 190 z O FILTER FABRIC r a O O '0 � O z4' 4' o PERF PIPE p 411J z / z I II 1111 DRAIN n n i �/ `ABOVE PIPE 6INV 'n n U 1250 G SEPTIC TANK DESIGN PARAMETERS PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 4 (600 gpd) TANK SIZE: 1250g SEPTIC PERC RATE = 1.41 MPI SOIL RATING: 1.2 GPD/SF AREA RCD: 500 SF SYS. TYPE: DEEP TRENCH 5.O'ED RF: — MIN LENGTH: 50 LF USED: 52.5 LF X 2.5' WIDE, 5.3' E.D., 10.0' TD TOTAL AREA: 556.5 SF TRENCH SEE DESIGN PROFILE LEGEND W WATER LINE/ WELL RADIUS SS — NEW SEPTIC LBBREVIATIONS CU COPPER DIP DUCTILE IRON PIPE TH TEST HOLE FC FOUNDATION CLEAN OUT T# TANK CLEAN OUT N0, Cn CLEAN OUT N0. m# MONITOR TUBE NO. RI _ RIGID INSULATION DCO DOUBLE CLEAN OUT DV DIVERTER VALVE FS FLOW SPLITTER BFG - BELOW FINISH GRADE OG ORIGINAL GRADE FG FINISH GRADE TS&V TOPSOIL & VEGETATE NOTES: s�� ���\� Date NONE ENG SVC, LLC RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 995110 �gF.A�gs�1� 12/15/201A PHONE (907) 272-8218 FAX (907) 272-8211 �g�p �y�� Scale NTS ................ ..... P.I.D. NO ALPINE TERRACE ELK 4 LOT 6 015-243-20 MAX & ANN FERNANDEZ P 1'e'veCER B' 49 no '� PERMIT NO. 11825 CIRCLE DR �+ czs•, � OSP141174 DESIGN DETAILS ANCHORAGE, AK 99507 +��IFPF�a sso�P sheet 3 OF 3 Permit Number: Tax Code Number: On -Site Wastewater Disposal System Permit OSP141174 01524320000 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Work Type: Septic Upgrade Permit Effective Dates: June 24, 2014 to June 24, 2015 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: ALPINE TERRACE Site Legal Address: ALPINE TERRACE BLK 4 LT 6 G:2740 Owner/Address: FERNANDEZ MAX & ANN JOINT REVOCABLE TRUST FERNANDEZ M A & A K/TRUS 11825 CIRCLE DR ANCHORAGE AK 995070000 Site Mailing Address: 11825 CIRCLE DR, Anchorage This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Lot Size in Sq Ft: 23000 Total Bedrooms: 4 N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Receive Issued Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 hftp://www.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program enc �o P N Department **** VARIANCEIWAIVER REVIEW **** Waiver#: OSP141175 COSA#: Permit#:OSP141174 PID#: 015-243-20 Legal Description: Alpine Terrace, Block 4. Lot 6 Engineer: PES Applicant: Max & Ann Fernandez Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 4.2 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ® The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. ❑, Adjacent properties are not affected by this waiver. ............................................................................... Waiver is Granted: X Waiver is not Granted: Date: Approved . Name of Reviewer ..........................................V., ....... .......................... MUNICIPALITY OF ANCHORA JUN n � Community Development Department vy Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-243-20 Property owner(s) MAX & ANN FERNANDEZ Day phone Mailing address 11825 CIRCLE DR, ANCHORAGE, AK ,99507 Site address 11825 CIRCLE DR, ANCHORAGE, AK, 99507 Legal description (Sub's., Block & Lot) ALPINE TERRACE BLK 4 LOT 6 Legal description (Township, Range & Section) Lot Size 23000 Sp. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field x❑ Initial ❑ Single Family (SF) X❑ (w/wo ADU) Septic Tank ❑X Upgrade n Duplex ❑ (D) Holding Tank ElRenewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: LOT LINE Distance:5 I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 45vi — [ Waiver Fees: S Date of Payment: / `t r Date of Payment: (0 1611 q Receipt Number: 0 2'�s Receipt Number: plqOZG Permit No. iO`�em In LA Waiver No. ob 12i OSPIy117,S Permit App_.;:-;L,:c� Pannone Engineering Services «c Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com June 23, 2014 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road P. O. Box 196650 Anchorage, Alaska 99519 Subject: Alpine Terrace Blk 4 Lot 6 Septic System Permit Request Ladies and Gentlemen: I am writing to request a permit to install a new septic system be issued for this property. The proposed systems will serve a existing four (4) bedroom house. Currently the existing field and tank are in failure . The proposed system will utilize a 1250g septic tank and a conventional drain field. The surrounding developed lots are served by private wells. There are no wells on surrounding lots within 100 feet of this system. Soils. We performed one test hole on this lot, and groundwater was monitored on 5/22/2014 and ground water was observed at 18 feet below the ground elevation in the test hole monitor tube. From 0.5' to 11' was an course sandy gravel with small traces of silt with a 1.4 MPI perk rate, but after 11' there is silty sandy gravel. It is my opinion, based on the results of the soils tests, the use of a conventional system and overall soils appearance; an application rate of 1.2 gallons/day/square feet should be used for a conventional wastewater system. 1. Soil Absorption System Design. a. See Sheet 2 of the design package. 2. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 3. Topography: The existing topography slopes from the north to south at varying slopes from east to west but at approximately 6% in the area of the proposed drain field. There are no steep slopes within 50' of the proposed drain field. 4. Waiver Request: To ensure a separation distance of 10' from the existing seepage pit the Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-5213 FAX: (903) 272-8211 Page 2 of 2 proposed drain field, a lot line waiver will be required to 4.2'. The lot adjacent to this has a septic system at a distance of 70+ feet and a well at 160+ feet to the proposed system. The proposed installation should have no adverse effect to the property. 5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On -Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of the surrounding or existing lots. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Mailing: P.Q. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor Ave, Anchorage, AK 99501. Telephone: (907) 272-8218 FAX: (907) 272-8211 �AA L` � N Al EXISTING TANK TO BE ABANDO �.y 1250 GAL TANK (P) \4 BEDROOM �� 1 HOUSE ., 50 RESERVE RAIN FI LD (P) �- 10 LF x2. 'W x 5. ' E. D., 10.O'TD / PRIMARY DRAIN FIELD I 50 LF X 25' WIDE, 5.0 (E) L DRIVEWAY / X3'1 AN FIELD / J PER CODE ,- SEPTIC AREA (E) )12 —TH1 10.0' TO a \ SEPTIC AREA (E) NOTES: PAMONE ENG SVC, LLC ..-�'pF A(���� Date 014 FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 �� PHONE (9D7) 272-8218 FAX (907) 272-8211 /�g�Qy�t Scale 1"=50' �...... ... P.I.D. NO ALPINE TERRACE BLK 4 LOT 6 / 015-243-20 MAX & ANN FERNANDEZ Steven R: 'Pannone'% PERMIT No. P/. CE 8149 % 11825 CIRCLE DR trf s ., OSP141174 PLAN ANCHORAGE, AK 99507 Ili' \RpE"-�+ She etOF 4 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS AND ATTACHED PES SPECIAL PROVISIONS. 3. SCOPE OF WORK: ABANDON OLD TANK AND PIT. INSTALL NEW 1250 GAL SEPTIC TANK AND SOIL ABSORPTION SYSTEM. 4. GROUNDWATER WAS ENCOUNTERED AT A DEPTH OF 18 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE, IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. ALPINE TERRACE ELK 4 LOT 6 ILTER FABRIC 4" 0 PERF PIPE ROCK 6" ABOVE PIPE INV OSP DRAIN ROCK ' 5.0 1 2.5 '— GM/ 8.0 SECTION SM -19.0 w w D FILTER FABRIC j O o wo 0 0 m� z o 4" 0 PERF PIPE p z pUp pUp pDpUp Z Z II II IIII [I n fl- DABOVE PIPE 6INV n (I U 1250 g SEPTIC TANK (P) DESIGN PARAMETERS PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 4 (600 gpd) TANK SIZE: 1250g SEPTIC PERC RATE = 1.41 MPI SOIL RATING: 1.2 GPD/SF AREA ROD: 500 SF SYS. TYPE: DEEP TRENCH 5.0'ED RF: — MIN LENGTH: 50 LF USE: 50 LF X 2.5' WIDE, 5.0' E.D., 10.0' TD TOTAL AREA: 500 SF TRENCH SEE DESIGN PROFILE ABBREVIATIONS CU COPPER LEGEND DIP DUCTILE IRON PIPE W WATER LINE/ TH TEST HOLE FC FOUNDATION CLEAN OUT WELL RADIUS T# TANK CLEAN OUT NO. — SS NEW SEPTIC C# CLEAN OUT NO. M# MONITOR TUBE NO. R.I. RIGID INSULATION DCO DOUBLE CLEAN OUT DV DIVERTER VALVE FS FLOW SPLITTER BFG BELOW FINISH GRADE OG ORIGINAL GRADE FG FINISH GRADE TS&V TOPSOIL & VEGETATE NOTES: PANNONE ENG SVC, LLC ����•��� Date FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 (�QF.A�gS>t'�l06/23/2014 PHONE (907) 272-8218 FAX (907) 272-8211 r'G��Qy�r Scale NTS " ' • P.I.D. NO ALPINE TERRACE BLK 4 LOT 6015-243-20 MAX & ANN FERNANDEZ Steven Pannone' PERMIT NO �.•. CE 8149 '�-� OSP141174 11825 CIRCLE DR+qs.,_� DESIGN DETAILS ANCHORAGE, AK 99507 �l�gpSONP Sheet 2 OF 3 TEST HOLE 1 ORGANICS 2 3 4 5 COURSESANDY GW/SP GRAVEL WTH 6 SOME SILT 7 8 9 10 11 12 13 SOILS LOG - PERCOLATION TEST SLOPE X TH WAS GROUND WATER 14 ENCOUNTERED? N 15 SLIT SANDY IF YES, AT WHAT GM/SM GRAVEL 16 DEPTH? -- 17 DEPTH TO WATER AFTER MONITORING? -18.0'- 18 5122/2014 DATE: 5/22/2014 19 BOH 20 DATE PERFORMED: 5 /1 612 01 4 ' a0ll PLAN N �M �H M \4 BEDROOM y HOUSE 3 Wim_ ti,_ SLOPE TH X READING DATE CLOCK NET TIME WATERTIME LEVEL READING NETDROP 1 5/16/14 11:55 -- 2.14 -- 2 12:05 10 MIN 9.18 7.02 3 12:07 --- 2.26 --- 4 12:17 10 MIN 9.33 7.07 5 12:20 --- 2.42 --- 6 12:30 10 MIN 9.51 7.09 PEROLATION RATE _ 1.41 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 3 FT AND4 FT COMMENTS: Test hole excavated by DIGGER DAN'S BACKHOE. PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLIINEES IN EFFECT ON THE DATE OF THIS TEST. NOTES: PAMONE ENG SWC, LLC �1�Date FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 i ��•" ..... 6/23/2014 �) PHONE (907) 272-8218 FAX (907) 272-8211 /�aj�p !y}} Scale •.*r Nrs �....... .. .. ... P.I.D. NO ALPINE TERRACE BILK 4 LOT 6 ... 015-243-20 MAX & ANN FERNANDEZ Steven R. Panno e PERMIT NO. }P�/� CE 8149�� OSP141174 11825 CIRCLE DR } _ SOILS LOG ANCHORAGE, AK 99507 (�1 ......... sheet ,� ROFES � 3 OF 3 4" JIM 4° PUMP—OUT. SLIDE SECTION OF 6" PIPE OVER THIS CONNECTION TO PROVIDE SHEER PROTECTION— EXTEND TO BRIDGE EXCAVATION ADVANTEX DESIGN - RESERVE SYSTEM 2EA ADVANTEX 24" AX20 PODS INSULATED DESIGN PARAMETERS RESERVE SEPTIC SYSTEM NO. BEDROOM: 4 (600 gpd) TANK SIZE: 15008 S.T.E.P. W/ AX20 POD PERC RATE = 1.4 MPI SOIL RATING: 6 GPD/SF AREA ROD: 100 SF SYS. TYPE: DEEP TRENCH 5.0' E.D. MIN LENGTH: 10.0 LF USE: 10.0' LF X 2.5' WIDE, 5.0' E.D., 10.0' TD TOTAL AREA: 150 SF AUXILIARY PUMP BASH PASSIVE AIR NOTES:PAMONE ENG SVC, C LLC ' P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 ��` "�\� •� r '(��F .... � /�fiD�p'•�-9++ •* / W *m .. .... Steven R. Pannone / 0 I,+ ��• CE 8149 1/ it �A� • • • • • PVL Date s/23/zo14 FOR CONSTRUCTION FOR FUTURE CONSTRUCTION Scale NTS P.I.D. 0 5-243-20 RESERVE SYSTEM ALPINE TERRACE BLK 4 LOT 6 MAX &ANN FERNANDEZ 11825 CIRCLE DR ANCHORAGE, AK 99507 PERMIT No. OSP141174 SITE SECTION sheet 4 OF 4 GREA' R ANCHORAGE AREA BOR( `GH Department of Environmental Quality 3500 Tudor Road Anchorage, Alaska 99507 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM ,,JJ NAMELG X/ �f2/U.C1N-96Z- MAILING ADDRESS sold 1'10.3�5�,G� PHONE3y����7 LOCATION J LEGAL DESCRIPTION LST �" ��� `I/ SEPTIC TANK: DISTANCE/ / NUMBER OF FROM WELD,CI�TI�MANUFACTURER�Ti %C of Z' MATERIAL �� / COMPARTMENTS INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY �"2`� GALLONS. SEEPAGE PIT: NUIv1':',ER OF PITS DE ER �J OR WIDTH LENGTH—, DEPTH LINING MAT ERIALd�f /%' �l'�RIB SIZE: DIAMETER �/DEPTHDISTANCE FROM: WELL -� � fl /) TOTAL EFFECTIVE BUILDING FOUNDATION , NEAREST LOT LINE ABSORPTION AREA (WALL AREA) SQ. FT. ADDITIONAL ABSORPTION ^ V212 WELL: TYPE �/�'J�c �%�fo CONSTRUCTION .Of�i��CO�J� DEPTH v? / DISTANCE FROM: BUILDING / NEAREST %f NEAREST/ i f SEPTIC . SEEPAGE G/ FOUNDATION_, LOT LINE1�, SEWER LINE Z) TANK U., SYSTEM �O CESSPOOL /�`�% OTHER SOURCES-�/�Lu�i�-� APPROVED DISAPPROVED REMARKS DISTANCES: XzL5a c./ INSTALLED BY: EfC- PIPE MATERIAL: �i� sT a2w ' LOT SLOPE: Wit11o21&/; REMARKS: 7,V101- �i ?xelz nOo I_ `i Form PW -026 DIAGRAM OF SYSTEM GREA. ER ANCHORAGE AREA BOR jUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3500 TUDOR ROAD POUCH 6-650 ANCHORAGE, ALASKA 99502 TELEPHONE 279-8686 SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT NAME OF APPLICANT - -I :- INSTALLATION LOCATION LEGAL DESCRIPTION `' 6 / INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED PERMIT NO. _ MAILING ADDRESS '` �'" /� L- ! PHONE w! Z SEEPAGE PIT DR141N „FIELD A / /-'%/i !' 1 �f / OTHER ..7CSV% 1 FINANCED THROUGH TO BE INSTALLED BY L J SOIL TEST RESULTS �-5 NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE / -z' TYPE, G r ( SEEPAGE AREA SIZE TYPE MINIMUM DISTANCES, REQUIREMENTS DIAGRAM OF SYSTEM FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT , DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK , SEEPAGE PIT '� DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK `"� SEEPAGE PIT© , DRAIN FIELD ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK DRAIN FIELD SEEPAGE PIT SEPTIC TANK, , SEEPAGE PIT _ i , DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. C- I HEALTH AUTHORITY OR LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. DATF�� APPLICANT'S SIGNATURE DEPART f11E. 1-1 r 0f= EfF1 ii 1 R ON t' t_ Q 3500 TUDOR ROJAF) ANCHORAGE, ALASKA 99502 Performed For Max Fernandez -Oate Performed August. -IW-2 Legal Oescri nti on L o t B1 o c k xx u b d i v i s i on Alpine Terrace This Form Renorts Soils Log __Percolation Oenth Feet Soil Characteristics llop- The sediments were fairly Soil consistnat with a high sand. 2 -ANAL— and cobble content. There were some erratic sand and 3 pebble layers but these accounted for less than 5% of the total sediments. 5- 6 GW 7 9 n Was Ground Water Encountered? No If Yes, At what Depth? Readinq 1 Date I Gross Time `The l __1._._4--.F_._ 4-- _� i 1 -Thelot was flat. Ji - Net Time Tenth to H2O 11 Net Dron; Percolation Rate i n ,I t C-. P ro ro s e d Instal 1 a t i 11,) p. e.,- n I P -j t F) Depth of Inlet. 1) e n J-1 h To Rot. t om 0 f 11 i t T r e n c h 14.fs.et CnMMENTS:, Gw Test Performed Ry P a e r t. i F i e,,i r-) a t Au