HomeMy WebLinkAboutALPINE VILLAGE BLK 4 LT 18 GAA~-HD-I Gll 'ER ANCHORAGE AREA BOROI, '! DEPARTMENT OF ENVIRONMENTAL OUALI'i ~' 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM · ~ ,,c, . ADDRESS~.._5(~t LOCATION ~- ~,'~-,~ ~'.4 /~'~ ~:' ~f;[-~,-~ LEGAL DESCRIPTION ¢":u/~ /'?-* ,,~/ '-Z~/~'~Z L~' '"~" SEPTIC TANK: ~ ~/~ ,,, DISTANCE FROM WELL/, LIQUID CAPACITY MATERIAL :~z/J~:,~',..%r"t~¢~_,~_~ ' NUMBER OF / , COMPA RTM ENTS ~------,' ._~__~ LIQUID GALLONS. INSIDE LENGTH INSIDE WIDTH DEPTH SEEPAGE SYSTEM: NUMBER OF PITS LINING MATERIAL_ NEAREST LOT LINE SEEPAGE PIT: / OUTSIDE DIAMETER OR WIDTH /x.Zj~.' , LENGTH //7/. , DEPTH DISTANCE FROM WELL /.>'_/2'(~'~'-~:],':;'~/' BUILDING FOUNDATION,~-'.~.;'.Z~--)/~:.~:'~ ' TOTAL. EFFECTIVE ABSORPTION AREA (WALL AREA) ',..-) ._D~ h.~ SQ. FT, TILE DRAIN FJ[LD: DISTANCE FROM WELL_ . FOUNDATION. NUMBER OF LINES DISTANCE BETWEEN NEAREST LOT LINE TRENCH WIDTH ABSORPTION AREA DEPTH: TOP OF TILE TO FINISH GRADE WELL: TYPE ,/-""..~.,~)'~'~C,'~"~ , DEPTH LOT LINE ~.~,?~.)l NEAREST /(_j~)/,~._ SEPTIC · SEWER LINE , TANK TOTAL LENGTH OF LINES IN. TOTAL EFFECTIVE SQ. FT. LENGTH OF EACH LINE~ · DEPTH OF FILTER MATERIA IN. ABOVE TILE DISTANCE FROM W A T E R~'""'~'~'~'.-.~,.~ BUILDING FOUNDATION. _SAMPLE , '"'t~E~EST ~__ ! SEEPAGE / OTHER ~ , SYSTEM / '"(-~ , CESSPOOL , SOURCES DISTANCES: DIAGRAM OF SYSTEM // DATE /'~ ¢~~,,~GE DISPOSAL SYSTEM- APPLICATION AND PERMIT NAME OF APPLICANT '~2 ~ MAILING ADDRESS Z~¢ P~' '~ pH~~~ INSTALLATION OF: SEPTIC TANK ~ SEEPAGE PIT ~ / , DRAIN FIELD OTHER TYPE AND SIZE OF FACILITY ,O BE SERVED ~ >~~ ~~~ ~ SOIL TEST RESULTS COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL SE SUBJECT TO PROSECUTION. DRAIN FIELD , DRAIN FIELD SEPTIC TANK SIZE ~ MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE Pit ~R SEPTIC TANK TO SeePaGE Pit WALL /~ SEPTIC TANK , SEEPAGE PIT ~0~ TO NEAREST LOT LINE. WELL TO SEPTIC TANK SEEPAGE PIT Drain FIELD /~01 ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK /0 ' , SEEPAGE PIT /Or DRAIN FIELD ,/O/ SEPTIC TANK, ~'~' P ,'kSEEPAGE PIT /00 ~ ., DRAIN FIELD DIAGRAM OF SYSTEM TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET into UNDISTURBED SOIl. 4 INCH DIAMETEr CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit Fitted WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFOrm TO BOROUGh REGULATIONS REGARDING iNSTAllATION. ALTH AUTHORiTYoR LICENSED DESIGNER I CERTIFY THAT I AM PAMILIAR WITH THE rEQUIREMENTS OF GReater aNCHORAGE AREA BOROUGh ORDINANCE NO. 28.68 AND THAT THE ABOVE DESCRIBED SYSTEM iS IN ACCORDANCE WITH SAID CODE. DATE , . APPLICANT'S SIGNATURE · TESTING · EXPLORATION · CHEMICAL · MATERIALS · INSPECTION 1940 POST ROAD ~ July 20 , 19 72 ANCHORAGE, ALASKA W.O. 11725 Mr. Jens Jenssen 5000 Abbott Road Anchorage, Alaska 99507 279-258! SUBJECT: Seepage pit requirements, proposed 2-bedroom house, Lots 17 & 18, Block 4 Alpine Village Subdivision, Anchorage, Alaska Dear Mr. Jenssen: In accordance with your request, we have made a soils log to determine the size requirements for a seepage pit to be located about 40 feet west of your proposed house at the above location. Our soils technician, Mr. John Weitz, logged the soils on July 19, 1972, as follows: Depth Description 0 to 1' 1 to 2-1/2' 2-1/2 to 4' 4 to 12' Peat Brown sandy gravelly silt Blue to grey fine sandy silt Tan sandy gravelly silt Ail soils were classified in accordance with the attached Soils Triangle. A value of 250 sq. ft. of wall area per bedroom has been assigned to the soils as a reasonable value because the silt content is estimated at 40 to 50 percent. By the Soils Triangle, 40 percent or more silt renders a soil to be classified a silt; however, by the Unified system, the material is SM. The sand-gravel components increase soil permeability to provide a higher seepage capability than with a silt (300 sq. ft. of wall area per bedroom). The water table was not encountered in the backhoe excavation at the time of exploration. Using an effective interval of 2 to 8 feet (2' cover, 4' above water table), a house with two bedrooms would require 84 feet of pit perimeter (21'x21' , for example) while a one-bedroom house would require 42 perimeter feet (10-1/2'x10-1/2') . Very truly yours, Staff Engineer PGH: id MEMBER 128 117 ~k 127 -<(~> 129 137 Al)bott Loop Area Reference Map-P11 August 16, 1972 David :'(el son 321'~0 Peterkin ~12 :~ubject: '.~el') oF~ Lots il, lJ3 Alpine Vtllat~e Subcitvision it i~as co~,~e tu our ~ttention that th~ well drilled for yo~(r residence o~) t~e suaject property is located only t~) s~wa?e disposal syste~ on Lot ~ D)Qck 4 Alpine Villa)c ~ubdivision. l'nis 7S fee~ Is 25 feet s~orC of t~)e requir~ ~ini~d;:~ ?rotec~ive radius between ~ scw~?c absor;.~tiun and a private uell. It should be also norad Chac y~L~L~r ,~eil is do~'lqrade fro~, the sa~,)e sewer syste~. 'F~.~is J~p~rc~:e:l~ coul:~ not :ran~ appro¢<~l 'to .ymur ~ny per?use b~Jcaus~ of its proxl~,~ity to Che n~i:jhbors ~ro~cec~i~n for your 1) i'~or soil conditions £) SysC~';~ in question is a drain fi~l~. 3) Adjoi~)in{) syste~,) lnsCalled in lSiT0 '.~,~ell drilled through i~:~pern'.eahle layers .~cause of the ~oor soil conditions i~. is 6ou~.cful Chat can penetrate a groat distance and because oB stow iL is doubtful bacceri~ could be curri~d throud;~ Che soil co any ~)reat extort:. Also the nuighborl~')~ sys'Ce~ ~as i~stalle~.~ i~ an~ it i~ li)<ely that bacteria fro~) that systat,:. ))~:~s ~-,~xi~lu~,'~ dtsCance. ~ocause the systc~ too clos(~ Co Ch(~ ~,~:ll is a dratnfield it has no way of overflowtn(j ~n~ cannot ru~'~ Uown o~') your property ~ow~rds your well. Also tf your well properly inst~lled ~nd passes through i~n?er)~e~ble ~a~erial such as clay, conta~ination is unlikely Co spre.~,.] co yo~ar ~qui fur. )~r. David Nelson August 16, 197~ Page two It is however, our recom~.~Jendation that the ~cll be ~J~oved to .~ lock 4 ot least log feet fro~) the seuer sys~e)~ on Lot l, ~ , Alpine Village Subdivision and that hook-up to public sewer be in~J~ as soon aS possible, which looks as thuu!~:h it wilt be ~t leas,~~ tt~,{,~ years in the future. Best Euck to you. Si nc~r~ly, Joi)n ~'~. Lee, ~.$. E:~vircnme~tal S~.~rvtces Supervisor MUNICIPALITY OF ANCHORAGE  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 825 L Street - Anchorage, Alaska 99501 6 / 23 / 7 $ ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) davs for processing. 1. PROPERTY OWNER PHONE DAVTD NELSON 344-9737 * MAILING ADDRESS * no one at home -wiii 2210 E. 74th Court, Anchorage, A~ be gone PROPERTY RESIDENT (If different from above) PHONE 2. BUYER PHONE na MAILING ADDRESS na 3'. LENDIr~G INSTITUTION PHONE First Federal Savings & Loan Association - Attn: Sondra Adams 274-6561 ext 2J MAILING ADDRESS P. O. Box 4-2200, Anchorage, AK 99509 4, REALTOR/AGENT PHONE na MAILING ADDRESS na 5. LEGALDESCRIPTION Lots ±7 ~ 18 Block 4, Alpine Vi±lage STREET LOCATION 22±0 E. 74th Court, Anchora~e~ AK 6o TYPE OF RESIDENCE [] SINGLE FAMILY [] MULTIPLE FAMILY NUMBER OF BEDROOMS [] One [] Four [] Two [] Five [] Three [] Six [] Other 7. WATER SUPPLY [] INDIVIDUAL* - [] COMMUNITY [] PUBLIC UTILITY 79' depth * ATTACH WELL LOG. A well Icg is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach Icg if available.) 8. SEWAGE DISPOSAL SYSTEM [] INDIVIDUAL/ON-SITE** [] PUBLIC UTILITY **If individual/on-site, give installation date 9/8/72 If system is over two (2) years old an adequacy test is required by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010(3/78) P_iease climb fence for access. Access to tap water in thru garage, THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR I NSP ECTOR DIRECTIONS: NUMBER OF BEDROOMS 1. TYPE OF RESIDENCE [] SINGLE FAMILY [] MULTIPLE FAMILY 2. WATER SUPPLY [] INDIVIDUAL [] COMMUNITY [] PUBLIC UTILITY Connection Verified 3. SEWAGE DISPOSAL SYSTEM [] INDIVIDUAL/ON -SITE []PUBLIC UTILITY Connection Verified [~ptic Ta_.q,k or [] Holding Tank Size: "~ ~ (--') If Tank is homemade give dimensions: TYPE OF TANK TOTAL ABSORPTIQ~- AR EA 4. DISTANCES WELL TO: Absorption Area to nearest Lot Line [] ONE [] THREE [] FIVE [] TWO [] FOUR [] SIX PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED PERMIT NUMBER DATE INSTALLED INSTALLER SOILS RATING MANUFACTURER MATERIAL Septic/Holding Tank IAbsorption Area I Sewer Line [] OTHER lNearest Lot Line 5. COMMENTS DATE LEGAL DESCRIPTION [] APPROVED FOR BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) []~ISAPPROVED BY (Title)~/~ 72-010 (Rev, 3/78) Date ALASY )EPARTMENT OF HEALTH AND SOCIAL ' VICES DIVISION OF PUBLIC HEALTH Lab. No. BACTERIOLOGICAL WATER ANALYSIS Office PLEASE MAIL RESULTS TO: NAME ADDRESS CITY ZIP CODE Sample collected by Phone No. Date Collected. Sampling Address Time Specific place of collection REASON FOR SAMPLE SUBMISSION: [] Hiness suspected [] Health Regulated Establishment [] Other WATER SAMPLE SOURCE [-'] Well Type of casing ~ [] Improved (Enclosed, Covered) Spring [] Surface (Reservoir, stream, lake) [] Holding Tank [] Other Analysis shows this WATER SAMPLE to be: [] Satisfactory [] Unsatisfactory [] Questionable [] submit other sample [] Sample too long in transit to indicate reliable results. Sample should not be over 48 hours old at time of examination. [] Bottle broken or leaked in transit. [] Other SANITARIAN'S REMARKS Sanitarian's Signature ~EAD INSTRUCTIONS BEFORE ,COLLECTING SAM PI-~E 06-1220 (b) Rev. 1978 BACTERIOLOGICAL WATER ANALYSIS RECORD Source __ Date Recelved~ ': ~ ~ ,; Time Received p.m, Lab. No. Presumptive 1Omi 1Omi 1Omi 1Omi 1Omi 1.0mi 0.1mi 24 Hours 48 Hours , Confirmatory 24 Hours 48 Hours EMB, Multiple Tube Report:,, Membrane Filter: Direct Count Verification: L.TB Final Membrane Filter Results Reported By ,. Broth 24 hours: , ~ , Broth 48 hours: , 10mi Tubes Positive/Total Z0ml Portions Coliform/100ml BGB __. Coliform/lOOml Date Time: a.mo