HomeMy WebLinkAboutALYESKA #3 BLK 19 LT 6 GRE/ :R ANCHORAGE AREA BOF 'IGH Department of Environment Quality 3500 Tudor Road Anchorage, Alaska ggS07 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION 5EIZT-tC TAN K: MAILING ADDRESS~-~'~ DISTANCE .,/¢ FROM W E g t~¢//'"/.,~ MANUFACTURER INSIDE LENGTH. ~ INSIDE WIDTH MATERIAL ~.....~--.,¢, ? NUMBER OF COMPARTMENTS I.'IQUlD DEPTH ~ LIQUID CAPAClTY,¢'~.¢-'~"'?¢'~ GALLONS. TILE DRAIN FIELD: DISTANCE FR~ NUMBER OF LINES ,'-~UNUA, ,~r.,,~-~ NEAREST LOT LINE DISTANCE BETWEEN LINES _..~TRENCH WIDTH TOTAL LENGTH OF LINES iN. ~_~,~¢¢~,~:rIv E ABSORPTION AREA DEPTH: TOP OF TILE TO FINISH GRADE SQ. FT. LENGTH OF EACH LINE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE IN. WELL: TYPE~,~,~ CONSTRUCTION BUILDING FOUNDATION , NEAREST LOT LINE_ NEAREST ~ SEPTIC ~.~. SEWER LINE , TANK CESSPOOL OTHER SOURCES APPROVED DISAPPROVED REMARKS DEPTH SEEPAGE SYSTEM DISTANCE FROM: DISTANCES: (~' ~., , NSTALLED By: '///~-.~ ,,.~ SEWER LINE DEPTH: PIPE MATERIAL: LOT SLOPE: REMARKS: Form PW.027 DIAGRAM OF SYSTEM APPROVED ..... G.A.A.B. .~.~_. GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO, A!'4(THORAGE:. ALASKA 99502 t / ~ SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT INSTALLATION LOCATION ,_EGAL DESC.,,'T,ON. Z '/)19 INSTALLATION OFt" TYPE AND SIZE OF FACILITY TO BE SERVED SOIL TEST RESULTS · ~ _~M.,., .,~, ~ -- OTHER TO BE INSTALLED BY -- : ~''~'~ NOTE~ THI~ PER~ I~ NOT VALID WITHOUT ~IL ~T COMPLETION DATE ANTICIPATED PFRMIT VAI ID flNF YFAR FINAL INSPECTION, 24 HOUR NOTICE: REQUIRED, BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. DIAGRAM OF ~YSTEM MINIMUM DIBTANCE$. REQUIR-~'-u='"-~,,~ ' FOUNDATION TO FOUND'ATION TO SEEPAGE PIT'~"~ DRAIN FIELD /'SEPTIC ~NK TO~[ PIT WALL -- DRAIN F~~ . ALSO CONSIDER AREA WELLS. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. 4" £A.~T IRON .NIPfl0N · SE'PT1C PIPE WITII AIRTIGHT CRIB lA)H: ~../' CAPS I~lO <' .'" , required ~.~honevor l(ne crosses (CRIB 4' HINI~UH ABOYE' WATER under driveway, TABLE) 4 ]riCH SE:.tEfl CO~SI[;I~ AREA ~ELLS. S[[PAC[ Pil F. XCAVATIO¢t RASED 0N ~:LL~e SOII. TEbT. HOUSE CAST l~flH~ .q ~-'SEf'TIC · K I'I P[' S' If:TO UI;- / I'~'--"--~--,---,,~ 4 IHCH !?,[,L._~. DISTUR~£~/~'---'-~ r ~C.~T IRON SIPIION PIPE SOIL .,,~ PIT - 200' ~... I.. Grade: 2'.per or I/4' p.r font except 10' precrudir tank & the. shoutd eot exceed 7%, 6' per 100 on flat te~ains. CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. C ,': OR ~ . ~ ~ LICENSED DESIGNER ., ~ ' " ~ ' ':" / AM ~ ' ~ ' , CERTIFY ~:T ~MC ~~; THE REQUIREMENTS OF ~ R EATER ANCHORAGE D~S~RIB[D SYSTE~ IS IN A~CORDANC[ WITH SAID ~ODE, DATE '=~{ APPLICANT'J ~IGNATURE ' '"