HomeMy WebLinkAboutALYESKA #3 BLK 21 LT 14/
0
M-W DRILLING, Inc.
P.O. Box 10-378 · 10300 Old Seward Highway
(907) 349-8535
ANCHORAGE, ALASKA 99511
DRILLING LOG
Well Owner PETE1[ ~L~B~ ~~ Use of We]] ~om<;,~;~t.:k~'
Location (address of: Township, Range, Section, if known; or distance main road
LOW 14 glock 21 Alyeska Sub. 3rd Add.
Size of casing ~," Depth of Hole 100~ feet Cased to 4o.60 feet
Static water level ~¥,:, It. (above) (below) land surface. Finish of well (check one)
Screen ( ); Perforated ( ),
Describe screen or perforatio~ Iqmm
Well pumping test at 1 gallons per (l~/m~)
of drawdown from static level.
Date of completion ~,]nv~,~h~. ~, . 1 q/t'~
Depth in feet from
ground surface
0 TO. 2
2 .TO 12
12 TO 14
14 TO 24
24 .TO 32
32 TO 36
36 .TO i00
.TO
.TO
.TO
.TO
.TO
__.TO.
.TO
.TO.
open end ( k×k);
(minute) for L hours with i00~
WELL LOG
Give details of formations penetrate~i, size of material, color and hardness
Casing atickup
Backf~l~
Organic
Silty gravel (damp)
~ravely ailt, hard
Broken up bedrock
Bedrock, varicolored small water aeeps in s~oradtc fractures
"'"'a ~e lVo,~."8~Oatraetor
3 -- CONTRACTOR
Department
825
P~ermit ~
~plplicant:
Location:
MUNICIPALITY OF ANCHORAGE
f Health and Environmenta3 Protection
~ Street, Anchorage, AK. ~501
264-4720
* * * HANDWRITTEN PERMIT * *
WELL AND/OR C.~-"~:,T~'~'"'~--?, PERMIT
Phone Number:
L~gal Description: L~,.7~ /~._/. Lot Size:
T~pe of Soil Absorption System Is:
Trench: Drainfield: Seepage Bed: Holding Tank:
Maximum Number of Bedrooms: '~ Soil Rating(sq.ft/br) ~/~,
The Required Size of the Soil Absorption System Is:
DEPTH .~'~7 . .. LENGTH ~ GRAVEL DEPTH (f~) WIDTH c"~
The length dimension is the length(in feet) of the trench or drainfield. The
d~pth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in feet). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall Pipe and
the bottom of the excavation(in feet).
* * REQUIRED SEPTIC(HOLDING) TANK SIZE = GALLONS * *
P~rmit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
o'f~residences that the well will serve.
* * * TWO(2)'INSPECTIONS ARE REQUIRED * * *
Backfilling of any system without final inspection.and approval by this department
will be subject to prosecution.
Minimum distance between a well and any on-site sewage disposal system is 100 feet
fOr a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance from a private well to a private sewer line
is: 25 feet and to a community sewer line is 75 feet. Well logs are required
an'd must be returned to this department within 30 days of the well completion.
Other requirements may apply. Specifications and construction diagrams are
available to insure proper installation.
* * * PERMIT EXPIRES DECEMBER 31, 1 9 8 3 * * *
I certify that:
(1) I am familiar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site sewer system may r~ire enlargement if
the residence ~-remodeled to include more that ~ ~edrooms.
Signe~:~.'~', ~., ~,- ~/~/~~/ Issued by .
~pp~icant / ~
. Date:
SWP/024 (1181)
June 2, 1977
TO: Wh~m It May Concern
SUBJECT~ Lot 14 Block 21 Alyeska Subdivision
3rd Addition
This office has no objection to the construction of
a cabin on the above cited lot that will utilize a
chemical toilet and will not be wet plumbed until
public sewer is availaB~e. When public sewer is
available the cabin must be connected.
If there are any furthmr questions, please contect
this office at 279-2511, extension 224 or 225.
Sincerely,
Joseph $. Blair, R.S.
Environmental Services Manager
JSB/lJh
F
M ~g")" ,~
SUBJECT
MEBBABE
® / /
~ SIGNED DATE
J"~-'-~t~, 4S 472 SEND PARTS I AND 3 WITH CARBON INTACT -
PART 3 WILL BE RETURNED WITH REPLY. pcx¥
DETACH AND FILE FOR FOLLOW-UP