Loading...
HomeMy WebLinkAboutALYESKA #3 BLK 21 LT 14/ 0 M-W DRILLING, Inc. P.O. Box 10-378 · 10300 Old Seward Highway (907) 349-8535 ANCHORAGE, ALASKA 99511 DRILLING LOG Well Owner PETE1[ ~L~B~ ~~ Use of We]] ~om<;,~;~t.:k~' Location (address of: Township, Range, Section, if known; or distance main road LOW 14 glock 21 Alyeska Sub. 3rd Add. Size of casing ~," Depth of Hole 100~ feet Cased to 4o.60 feet Static water level ~¥,:, It. (above) (below) land surface. Finish of well (check one) Screen ( ); Perforated ( ), Describe screen or perforatio~ Iqmm Well pumping test at 1 gallons per (l~/m~) of drawdown from static level. Date of completion ~,]nv~,~h~. ~, . 1 q/t'~ Depth in feet from ground surface 0 TO. 2 2 .TO 12 12 TO 14 14 TO 24 24 .TO 32 32 TO 36 36 .TO i00 .TO .TO .TO .TO .TO __.TO. .TO .TO. open end ( k×k); (minute) for L hours with i00~ WELL LOG Give details of formations penetrate~i, size of material, color and hardness Casing atickup Backf~l~ Organic Silty gravel (damp) ~ravely ailt, hard Broken up bedrock Bedrock, varicolored small water aeeps in s~oradtc fractures "'"'a ~e lVo,~."8~Oatraetor 3 -- CONTRACTOR Department 825 P~ermit ~ ~plplicant: Location: MUNICIPALITY OF ANCHORAGE f Health and Environmenta3 Protection ~ Street, Anchorage, AK. ~501 264-4720 * * * HANDWRITTEN PERMIT * * WELL AND/OR C.~-"~:,T~'~'"'~--?, PERMIT Phone Number: L~gal Description: L~,.7~ /~._/. Lot Size: T~pe of Soil Absorption System Is: Trench: Drainfield: Seepage Bed: Holding Tank: Maximum Number of Bedrooms: '~ Soil Rating(sq.ft/br) ~/~, The Required Size of the Soil Absorption System Is: DEPTH .~'~7 . .. LENGTH ~ GRAVEL DEPTH (f~) WIDTH c"~ The length dimension is the length(in feet) of the trench or drainfield. The d~pth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall Pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = GALLONS * * P~rmit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number o'f~residences that the well will serve. * * * TWO(2)'INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection.and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet fOr a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is: 25 feet and to a community sewer line is 75 feet. Well logs are required an'd must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31, 1 9 8 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may r~ire enlargement if the residence ~-remodeled to include more that ~ ~edrooms. Signe~:~.'~', ~., ~,- ~/~/~~/ Issued by . ~pp~icant / ~ . Date: SWP/024 (1181) June 2, 1977 TO: Wh~m It May Concern SUBJECT~ Lot 14 Block 21 Alyeska Subdivision 3rd Addition This office has no objection to the construction of a cabin on the above cited lot that will utilize a chemical toilet and will not be wet plumbed until public sewer is availaB~e. When public sewer is available the cabin must be connected. If there are any furthmr questions, please contect this office at 279-2511, extension 224 or 225. Sincerely, Joseph $. Blair, R.S. Environmental Services Manager JSB/lJh F M ~g")" ,~ SUBJECT MEBBABE ® / / ~ SIGNED DATE J"~-'-~t~, 4S 472 SEND PARTS I AND 3 WITH CARBON INTACT - PART 3 WILL BE RETURNED WITH REPLY. pcx¥ DETACH AND FILE FOR FOLLOW-UP