HomeMy WebLinkAboutALYESKA #3 BLK 22 LT 8AAlyeskct #3
Block 22
Lot 8A
#076 - 022 - 47
Data Drilled! ;-7-R4
WELL LOG
T' 8
'K. 22
+,ivpskL 5'0)(1.
Static Water Level feet Gallons Per Minute
Draw Down N/A feet Total Feet of Casing_ 20
Tyre Material Drilled!
0 feet
19 re,,,t
to 18 Sand, gavel
to 65 Porirnck
65 feet to 106 Fractune bedrock w/water
to
to
to
Hefty Drilling
S.R.A. Box 1553 H
A nchorage,Alaska
99507
MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
APR log;
RECEIVED
Date Dril1edA__ _7�8�i-----
WELD LOG
s
Do9hL MAeR
dot 8
Bik. 22
Alyeska Subd.
Jtatio Water Level 13-1 feet • Gallon Per Minute
Draw Down feet Total Feet of Casing la
N/A
Type Material Drilled*
0 feet to 1tl SAnd o rravw t
65 faat
t0WI•itajillt•dlota•••••••••••••••••••••••••••••••••••••••••••••IMM•MM11•••••••••••!...•e{c
t0 IAA F.iP tyrn hoAreirl( ri/srw par
to
to
to
Hefty Drilling
S.R.A. Box 1553 H
Anehorage,Alaska
99507
P. 01
MUNICIPALITY OF ANCHORAGE
Department . Health and Environmenta" 'rotection L,4C AW
825 L Street, Anchorage, AK. 9501
264-4720
* * *
Permit # HANDWRITTEN PERMIT # * *
WELL PERMIT +
Applicant :)`, t .E L% 4 1�1_ Mailing Address : 3 , t t.�' `,1'co-,`
Location: Phone Number: 5 Vg -.-"T"7 L4
Legal Description: C - s r3 - 1 Q-A Ly42,5 kA a•J Lot Size:
Type of Soil Absorption System Is:
Trench: Drainfield: Seepage Bed: Holding Tank:
Maximum Number of Bedrooms: Soil Rating(sq.ft/br)
The Required Size of the Soil Absorption System Is:
DEPTH LENGTH GRAVEL DEPTH WIDTH
The length dimension is the length(in feet) of the trench or drainfield. The
depth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in feet). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall pipe and
the bottom of the excavation(in feet).
* #REQUIRED SEPTIC(HOLDING) TANK SIZE = GALLONS #
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
of residences that the well will serve.
* * * TWO(2) INSPECTIONS ARE REQUIRED * *
Backfilling of any system without final inspection and approval by this department
will be subject to prosecution.
Minimum distance between a well and any on-site sewage disposal system is 100 feet
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance from a private well to a private sewer line
is 25 feet and to a community sewer line is 75 feet. Well logs are required
and must be returned to this department within 30 days of the well completion.
Other requirements may apply. Specifications and construction diagrams are
available to insure proper installation.
* * PERMIT EXPIRES DECEMBER 31, 1 9 O
I certify that:
(1) I am familiar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I wi i stall the system in accordance with codes.
(3) I u der-�-d that e on-site sewer system may require enlargement if
the re �S:;ace is' modeled to include more that 3 :-drooms.
Signed:
SWP/024(1/81)
Issued by:
Date:
oo
0
J
SUBDIVISION:
1 ho�Se
S•}e
V
F -
w
w
r
U)
1--
O
z
W
J
U
(75
U w
wo
(/) Z
a
W 2
Z
J O
wCC
U F,.
5 z
O
wU
w
cc
z
wO
U
sn,6 0
0
1
;fib Yep 4:4Cc
w
F-
a F"
c.) cc
EO
z z
L
11:1Od38 NO1103dSN1 1:13/v13S
SIZE MAIN:
w
Q
0
INSPECTED BY:
'2?
CONNECT :':)U
~ `' Do[u //
--.__—'-- /ei/
nspocLnr
�.ui'(ivisio/
(Tine_ ,�f>^�i�\4��
_--_-__��-~'~�._�~ ---''_—
'
AdcrcS S
-- ?AZ . -- ----—-----
�
'..;oter SiZ� Pennit Y�� No �
_--_-
/�°
�ewe r Si7c `~- P8rn|it Yes H0 x ii _-__-
LOCATION SKETCH \10
`
-
\/
q
r
�
,,�M�� ~'
n ,//�,'� 'r
. . � �.'��~
''�.�~i�7_^-
r.-----1��.
,-- ~
/
.'.
n
(
/.-
^'
��
\
��
./�
-x�v
' >`'� V
��� �U' /�
. / �
c�� /
�(�� '*
`«. `
'i-
(1'
Municipality of Anchorage
On -Site Water and Wastewater Program
(907) 343-7904
Certificate of On -Site Systems Approval
Parcel I.D. 076-022-47
1. GENERAL INFORMATION
Expiration Date: / 0 / 7 - / 3
Complete legal description Alyeska #3, Block 22, Lot 8A
Location (site address) 246 Higher Terrace Girdwood, AK 99587
Current Property owner(s) James & Julie Doepken Day phone
P.O. Box 994 Girdwood, AK 99587
Mailing address
Real Estate Agent Day phone
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
4. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
Three
TYPE OF WASTEWATER DISPOSAL:
Individual
❑ Holding Tank
❑ Community
❑ Public Sewer
WaiverNariance request for: Distance:
/ I5 l
Received by: l,2 ` 0 .2 T2 9
COSA to be rete sed to the ebgineer, unless otherwise requested by the engineer.
Date: 71. °'
COSA Fee $
Date of Payment
Receipt Number
COSA #
'l /11113
oariNG
05r✓t313 iq
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
6. DSD SIGNATURE
System #1 Approved for bedrooms
System #2 Approved for
Disapproved
Conditional approval for
bedrooms
Phone 522-7773
Date 7/10/2013
*; 49TH av ,
•
7
;A cHAEL E. ANDERpj
# •, CE -4381 e 4':
�RLOs o 0
bedrooms, with the following stipulation®�1s=®®ApFES5Ssea®®
BBy:
fir AP-
T = unic,':•lity And/age Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
0`OP �C/y,pi
�(�
.. ON-SITE 0
g WATER ANn "' -
a WASTEWATER o1
PROGRAM S`
�JiJJj), ! SER ��,,�
Original Certificate Date: 7 - / 7 -1-
7. ATTACHMENTS:
COSA Checklist X _
Septic System Advisory
Well Flow Advisory
COSA blue sheet t
Nitrate Advisory. ;
Arsenic Advisory
Other
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: Alyeska #3, Block 22, Lot 8A
A. WELL DATA
Well type Private If A, B, or C provide PWSID #
Date completed 5/7/84 Sanitary seal (Y/N)
Total depth 106 ft. Cased to 18 ft.
Date of test
Static water level 15 ft.
Well production 6 g.p.m.
FROM WELL LOG
5/7/84
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL Nitrate N/D mg/L
Arsenic N/D ug/L Date of sample: 6/26/13
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material
Tank size gal. Number of Compartments
Foundation cleanout (Y/N)
Date of pumping
Parcel ID: 076-022-47
Well Log (Y/N)
Wires properly protected (Y/N)
Casing height (above ground) >12 in.
AT INSPECTION
6/26/13
26.9 ft.
6.7
g.p.m.
Collected by: Anderson Eng.
AWWU Sewer
Date installed
Cleanouts (Y/N)
Depression over tank (Y/N) High water alarm (Y/N)
Pumper
C. ABSORPTION FIELD DATA AWWU Sewer
Date installed Soil rating (g.p.d./ft2 orft2/bdrm)
Length ft. Width
Total depth ft. Eff. absorption area ft2
System type
ft. Gravel below pipe
Monitoring tube Depression over field
Date of adequacy test Results (Pass/Fail) For bedrooms
Fluid depth in absorption field before test in. Water added gal. New depth in.
Elapsed Time: • min. Final fluid depth in. Absorption rate >= g.p.d.
ft.
Any rejuvenation treatment (past 12 mo.) (Y/N & type)
If yes, give date
D. LIFT STATION
Date installed
"Pump on" level at in. "Pump off" level at
Datum Cycles tested
AWWU Sewer
Size in gallons
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
>25'
Animal containment areas >50'
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation Property line
Water main Water service line
Wells on adjacent lots
ABSORPTION FIELD ON LOT TO: AWWU Sewer
N/A
N/A
19'*
Sewer /septic service line
in.
Property line Building foundation
Water Service line Surface water
Curtain drain Wells on adjacent lots
Manhole/Access (Y/N)
High water alarm level at
Meets alarm & circuit requirements?
On adjacent lots
On adjacent lots N/A
96'**
N/A
in.
Public sewer manhole/cleanout
N/A
Holding tank
Manure/animal excrete storage areas
>100'
Absorption field
Surface water
Water main
Driveway, parking/vehicle storage
F. COMMENTS
**Separation Distance Waiver Issued 6/18/96. Lot is Served by AWWU Sewer.
G. ENGINEER'S CERTIFICATION
I certify that 1 have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date • 7/10/2013
COSA brown sheet_1 D-1412.doc
i >& rT: #
oli MICHAEL E. ANDERSON •(� re
s s: GE -4381 •
a 1 • •E*d
f›'••••1Ioa �`
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 156650 Anchorage, AK 99519-6650
vnvw.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 076 022 —Afc/7
/30
to/Ji'F1ld3
I
F1AA # 1)40300/5
Expiration Date: Ve fi?
1. GENERAL INFORMATION
Complete legal description L.oI-Bf}r eloek 22 A1ynka• S/b -rt3
Location (site address or directions) 14 f, if Terr'aer Roc 6,rdo cue€C
Current Property owner(s) R e,o<ar Tenn ere" Day phone 787 - 00 yr
Mailing address ` ' P.G. So>c 23(, irrrcfwaoot', ',4k 99 6-87
Lending agency . an k Day phone
Mailing address
Real Estate Agent IX n k . Day phone
Mailing Address• Q} vs 3 -ooYS
Unless otherwise requested, NAA will be held by DSD for pickup. Pleo�e carf own trf or Q r %an
Walt @ 33T -817t Ar /� ekg/ wAm
2. NUMBER OF BEDROOMS: _L ready . - Tir-m
3. ' TYPE OF, WATER SUPPLY:' TYPE OF WASTEWATER DISPOSAL:
•
Individual Well
Individual Water Storage
Community Class Well
Public Water System
Individual On-site •
• Individual Holding tank
Community On-site
• Public Sewer ••
0
0.
airoimonmarassarrne
• The Municipality of Anchorage Development Services Department (DSD) Issues. Certificates of Health Authority
Approval' (HAA) based'only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title ,(except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system.' DSO' also issues HAAs upon request to homeowners."Certificates of Health Authority Approval are
valid for 90 days from the'date of issue for, properties served by a private or Class C well and may be reissued with
new water sample' results.'(Certificates may berreissued fora period of up to one year with valid water samples.)
Certificates are valid for one year forproperties served by.Class.A orB wells or a public water system. The
Municipality of Anchorage isnot responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined In the Health Authority Approval Guidelines for this application, shows that the on-
site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
Name of Firm F(cr/Fop TecAn;ca/ Ser:ac•,
Phone 3 5'6'- syn.-
Address
3SrAddress Iygao Echo 9.j 14, Acro •' Atc 99s-
Engineer's
9sEngineer's printed Name Theo ceore F t-fct 0 't• - Date Jan 7, 2003
5. DSD SIGNATURE
Approved for "/ bedrooms.
' Disapproved. .
=Conditional approval for
e: 1,
•
i;.•
«'s. ra •o•., .hv .
.:
(F �THECDCRE F. LtOOF„
' '.:. ••. CE 3589 ..t •rq
.. -6:1)::%9.• ****** •
y.,,...r*• ••• n\fl
bedrooms, with the following stipulations:; '_,.••
Additional Comments
Attachments: -
. HAA Checklist X Maintenance Agreements
Septic,System Advisory, • 'Supplem
` ental Engineer's Report
Well Flow Advisory Other '
Yam
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519.6650
www.ci.anchorage.ak.us
(907) 343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: / 0 f 6 Q/vc k 2 1 A l yv itm Sib # 3
A. WELL DATA
Well type Pvt
Date completed S/7/6y
Parcel ID: O r6-0
If A, B, or C provide PWSID # N. A. Well Log (Y/N) Y
Sanitary seal (Y/N)
Total depth 10 6 ft. Cased to 1 G ft.
FROM WELL LOG
Date of test 5 / ? 16 Y
Static water level 1 S
Well production 6
WATER SAMPLE RESULTS:
Coliform O colonies/100 ml.
Arsenic.
mg.A.
Wires properly protected (Y/N) i
Casing height (above ground) 2 N
AT INSPECTION
12./6/0z
fL 12'-Z''
ft. s.
g.p.m. .9. 1 g.p.m. »
wt Il flow frrf con ducPee/ 4Y
W,lta a.f Aare u• Pc( kit /1
in
%rv,c G
Nitrate < 0.2. mg./I. Other bacteria <J colonies/100 mI.
Date of sample:1? /Y /o Z Collected by: Aa re w PK..p sic eueli
B. SEPTICIHOLDING TANK DATA N. A. C A w wtt
Tank Type/Material
Tank size gal. Number of Compartments
Foundation cleanout (Y/N) _ Depression over tank (Y/N)
Date of pumping Pumper
C. ABSORPTION FIELD DATA N.A. (AwLc 4 Sea/<r)
Pe.- 1-elnonw. T.,.. Croi PSA
SILv<r• W,I/ cocci./ tMet /fall fs.•ysr
Date installed
Cleanouts (Y/N)
High water alarm (YIN)
Date installed
Length ft.
Total depth ft. Eff. absorption area
Date of adequacy test
Fluid depth in absorption field before test _
Soil rating (g.p.d./ft2 or ft2/bdrm)
Width ft.
ft2
System type
Gravel below pipe
Monitoring tube _ Depression over field
Results (Pass/Fail)
in. Water added_ gal.
Elapsed Time: _ min. Final fluid depth _ In. Absorption rate >=
Any rejuvenation treatment (past 12 mo.) (YIN & type)
ft.
For _ bedrooms
New depth_ in.
g.p.d.
If yes, give date
D. LIFT STATION N•A-• Chlei it- c SICAO ,er)
Date installed Size in gallons Manhole/Access (Y/N)
-Pump on' level at _ in. 'Pump off- level at _ in. High water alarm level at
Datum Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot u. A On adjacent lots N. A.
Absorption field on lot ti/ . A. On adjacent lots k/ • A .
Public sewer main 19' * i»
Public sewer manhole/cleanout
Sewer /septic service line 2 5 ' Holding tank M. A.
in.
96' V S -
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: W.A. ( Alva.
Sewerl
Building foundation Property line _ Absorption field l
Water main Water service line Surface water
Wells on adjacent lots
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: N• A. C A- w wac S ccuerj
Property line Building foundation
Water Service line Surface water
Curtain drain Wells on adjacent lots
F. COMMENTS
i-* S4, a roe hen .96171.4 nee Gciorver- urr'•s(
G. ENGINEER'S CERTIFICATION
1 certify that 1 have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA HAA guidelines in effect on this date.
Engineer's Printed Name They 41c:re
Date Yarn ua•-).7 2003
Water main
Driveway, parking/vehicle storage
6/18/90 wr39G0006
c A4 tt 1H,
J,4. a�•.,`'-
,r: * t- II y,f�1((T �NN te�r,;. . ,. .
�r1.... avlq+r{_r: • � 'E
e'.� K
f .?1t OD3?C r. tccgr
I., a•35 9 s
.• .
HAA Fee $ 3 '7.1 Waiver Fee $
Date of Payment
Receipt Number
(Rev. 12/01)
1/7/o?
z,fEcid4.J
Date of Payment
Receipt Number
G
r
Zan
Boz
to s
zx
J tif7
r `^ z
!' w z
N
(04
D Nzfl
X "
4
1.1
VI
I
r
r
n
r
N
z
0
z
P1
N
O
0;0
ifl
0
0
r
m
r
r
Rick Mystrom,
Mayor
Municipality of Anchorage
June 18, 1996
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
Chuck Eggener, P.E.
Chuck Eggener Consulting Engineers
PO Box 232946
Anchorage, Alaska 99523 2946
Subject: Waiver Request for Lot 8 Block 22 Alyeska Subdivision
Waiver #WR960006, PID #076-022-15, SW950377, HA950051
Dear Mr. Eggener:
Your request for waivers of the required 75 foot separation to a public sewer line and a
100 foot separation to a public sewer manhole have been approved. The approved
separation distances are the private well to the public sewer line of 19 feet and the private
well to the public sewer manhole of 96 feet.
This waiver approval applies to the existing well and public sewer line and manhole only.
Any future upgrade will require all separation distances be met or another approval from
this department.
If there are any concerns or questions regarding this matter, please call our office at 343-
4744.
E
Sincerely,
L'llc+.
7
Daniel J. Roth
Civil Engineer
On-site Services
DJR/ljm: waiver/miller
WR# Le` ethartnr4 c
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-site Services Section
Waiver Review Worksheet
PID# (l' _rn z -\A HA# Permit #
Date Received: (''1r1 -,(VN a1r 1c1`1ls /1
Legal Description: h4-.19 Q-A.,r r Pr) Al • -,4'r, ; ()
Engineer: Oh", r,, e S,r-a no., P 9 C h t,rn t_r-Pnf n ��nSt.�r�l,rt
(
t Mx4OtQ
Applicant:
******
Waiver Requested: 1 ,1 t t ,n 4t t , vt QQ 4 O
Mr L, -NS 1
/7
Criteria: 1. Geology:
A.
B.
C.
D.
E.
Water Table
Soil Sorption
Permeability
Water Table Gradient
Horizontal Separation
TOTAL:
2. Special Conditions:
Points:
3. Other:
Waiver is Granted:
Waiver is NOT Granted:
List Conditions or Reasons for above:
W/lnr t-iti. PE PONE To L.ELL ! fFt..ER
%NE C/IMICE Fat' eAvrAMntrar,ut, tam PSE
(ti 11GMEEinevr t-ory Una/14a OF r///s
Date: 4 -3- 9'4
SEE
Eacl/,vEfRS ADfiCaeP L ETTER DESCRtt/d'6
['AVE nS H/T/&g7/.yf neinuery Tv ExCLuPE
'UAW( ss.-Ete Leat. A.O. E: f, (flats fl twC,t‘) is
t..,t, ujif.
By: D/4V
Name of Reviewer
Rec #: (MI 1,CthrL011 Amount: $C\ l,4l
Date Paid: 2, -.etc -°tn
Chuck Eggener Consulting Engineers
June 14, 1996
Mr. Jim Cross
Program Manager - On -Site Services
DHHS
825 L Street
Anchorage, Ak 99503
RE: Asbuilt Drawing and Driller's Certification of Compliance for the Sleeving of the
Miller Well - Lot 8, Block 22, Alyeska 3rd Addition
Dear Jim:
In accordance with our telephone conversation of June 4, 1996 we have now completed
the sleeving of the Miller Well.
The work was performed by Dave Harper of Alpine Drilling on June 8, 1996.
The asbuilt drawing and driller's certification of compliance with the project specifications
are attached. The asbuilt drawing bears my original stamp.
All required fees have been paid.
We believe we have now complied with all of the conditions stipulated by your department
for grant of the well radius waiver. Those conditions were given to me by you on March 14,
1996 and restated in my letter to you on March 20, 1996. A copy of that letter is also attached.
Please review the enclosed materials and issue the waiver or call me if additional
information is required.
Thank you for working with us to bring this matter to closure.
Very truly yours,
7
Chuck Eggener, P.E.
P.O. Box 232946 • Anchorage, AK 99523-2946 • (907) 349-1010 • Fax: (907) 349-1015
From ALPINE DRILL- 907 345 0202
Tn: Doyle Miller
Re: rdwond property, Int 8, Mock 22 AIynsks Subdivision
Well at the above named property has been sealed with all materials and using the design
method as prescribed by Chuck Eggner. The work was completed on June 9, 1996.
D vid L. h1arper.,
Alpine Drilling & Enw
P.O. Box 110496
Anchorage, AK 99511=0496
FRACTURED BEDROCK
W/ WATER
v
2
immumininimmim
"el "/\/\/\/\/
n
n
0
z
y
c
z �
C)m
90
z
z
m
m
7,
Chuck Eggener Consulting Engineers
May 16, 1996
Mr. Jim Cross
Program Manager - On -Site Services
DHHS
825 L Street
Anchorage, AK 99503
RE: May 14, 1996 Video Tape of Sewer Main Inspection In Higher Terrace Adjacent
to the Doyle Miller Well on Lot 8, Block 22, Alyeska 3rd Addition
Dear Jim:
In accordance with conditions stipulated by your Department for grant of a well radius waiver
for the Doyle Miller well (Lot 8, Block 22, Alyeska 3rd Addition), which were recapped in our letter
to you dated March 20, 1996 (copy attached) - AWWU performed a video inspection of the sewer
main adjacent to the well on May 14, 1996. A copy of the video tape from that inspection is enclosed
along with the written inspection record prepared by the AWWU personnel who performed the work.
I have reviewed the video tape and the inspection report and concur with AWWU Manager
Bob Fuge's letter to Doyle Miller dated December 14, 1995 (copy attached) wherein he stated that
based on a similar TV inspection made on November 30, 1995 the sewer main was found to be "in
excellent condition" with "no anticipated problems in the foreseeable future".
We are assuming that the transmittal of this evaluation along with the accompanying video
constitutes compliance with condition #2 for grant of the waiver as stated in our March 20, 1996
letter. If after review of the enclosed information you have additional concerns about the integrity
of the sewer please contact us prior to May 31, 1996. Otherwise we will assume that sewer main
integrity has been satisfactorily confirmed and we will proceed with sleeving the well in accordance
with the drawing previously approved by your department.
Very truly yours,
Chuck Eggener, P.E.
P.O. Box 232946 • Anchorage, AK 99523-2946 • (907) 349-1010 • Fax: (907) 349-1015
Chuck Eggener Consulting Engineers
March 20, 1996
Mr. Jim Cross
Program Manager - On -Site Services
DHHS
825 L Street
Anchorage, AK 99503
RECEIVED
MAR 2 6 1996
Municipality of Anchorage
Dept. Health & Human Services
Formal Request for Well Radius Waiver
(Well to Public Sewer)
Lot 8 Block 22 Alyeska Subdivision
Doyle and Christie Miller
Dear Jim:
Thank you for your phone call of March 14, 1996 advising me that after your review of the
technical information I provided (during our meeting on January 5, 1996 and by fax on February 14,
1996) your department will grant a waiver request for the Miller Well subject to certain conditions.
We understand those conditions to be as follows:
1. The well will be sleeved in accordance with the attached drawing.
2. The structural integrity of the reach of sewer line adjacent to the Miller Well will be
confirmed by television inspection with a copy of the videotape to be provided to the
Department. The subject segment of sewer is the 8" ductile iron main between
manhole 619 and manhole 618 on Higher Terrace - 1980 Sanitary Sewer
Improvements Girdwood/Alyeska LID 60-1 Schedule 1.
Please consider this letter, supported by the information we presented earlier and other
information you already have in your file, to be our formal request for the well radius waiver subject
to the conditions stated above. Attached find our check in the amount of $920.00 for the waiver fee.
Based on our March 14, 1996 conversation the Millers are proceeding with the work required
to clear the waiver conditions. Please advise if you would like to have a representative present during
either the sewer main television inspection or the well sleeving operation.
I appreciate your extra effort in working with us to find an acceptable solution to this
problem.
Very truly yours
Chuck Eggener, P.E.
P.O. Box 232946 • Anchorage, AJC 99523-2946 • (907) 349-1010 • Fax: (907) 349-1015
C�r� l`lQls IaLVC'1 d -o P vt'JL,(_ ��kn
rck Mystrom.
Mayor
Municipality of Anchorage At k
Department of Health and Human Services 41-Wi
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
March 1, 1995
Wayne Henderson, P.E.
Peninsula Engineering
440 W. Benson Blvd.
Anchorage, AK 99503
Re: Waiver request for Lot 8, Block 22, Alyeska Subdivision, Addition #3.
Dear Mr. Henderson:
The On -Site Services Section has reviewed your request for a separation distance
waiver for the private well on the above mentioned lot. This request was for a
waiver to 21.1 ft. of the required 75 ft. separation between the well and the public
sewer line located in Higher Terrace. The submittal also requested a waiver to 96
ft. of the required 100 ft. separation distance between the well and a public sewer
manhole located in Higher Terrace.
The determination for the issuance of waivers is made according to guidelines
established by the Alaska Department of Environmental Conservation. Following
these guidelines, the On -Site Services Section has determined that this property
does not qualify for the waiver to 21.1 ft. from the well to the public sewer line.
As I mentioned previously, the fee for this waiver will be refunded at your request.
If you have any further comments or questions on this matter, please call me at
343-4360.
Sincerely,
hi/kirSL/iewf
ames Cross, P.E.
Program Manager
On -Site Water Quality
Parcel I.D. #
MUNICIPALITY OF ANCHORAGE • '
DEPARTMENT OF HEALTH & HUMAN SERVICES
•
Division of Environmental Services
On -Site Services.Section
P.O. Box 196650. 'Anchorage,'Alaska '-99519-6650
•' 343-4744 i; : i <
K ,- CERTIFICATE OF HEALTH AUTHORITY.,, , ,,
APPROVAL FOR A SINGLE FAMILY DWELLING
e,74. 02z —/S
•
1. GENERAL INFORMATION
HAA # r4 A q 5005
Complete legal description Lo 74-0 -BLoc 2�J ' -!' • �u-�
41d1,
Location (site address or directions) NklN / C -1e/e 7 R,4c E
A- L Yclrr4 ;4-K:
Property owner � YL -4— m t 4.1—E -
Mailing address
Lending agency
Mailing address
Agent
Address
Day phone 34'1"--'63/
Day phone
Day phone
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: '¢
3. TYPE OF WATER SUPPLY:
Individual well }�
Community well
Public water
rrrri
rn
rn
C7
7OZ
-11C1
rn
C.#4m
73
D
Lo ricz,
CON =
to,o
•0
z
S
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to
ttest
ingto the legality and status of system,14,
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
•
Community on-site
IA.
•
Public sewer
••;\, ..
i•• ;:�
- ,re ..
X '•'C)
NOTE: If community wastewater system, provide written confirmation from State ADEC-
•
attesting to the legality and status'of system.
72-025 (Rev. 1/91) Front MOA 821
•
5. STATEMENT OF INSPECTION ,BY, ENGINEER
As certified by my seal affixed hereto 'and as of the validation date shown below, 1 verify that my
• y:,,
investigation 'of this Health Authority,Approval,application shows that the on-site water supply
and/or wastewater disposal system is safe,, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further„ verify that based on the information obtained from
the Municipality 'of Anchorage files and from 'my investigation and inspection, the on-site water
supply and/or wastewater'disposal'system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm
N/ NiJ 1 4 'E,A)soti tt/M Phone
Address -4-40 W, S NSdA ) 3
%Engineer's signature
, :441114 44
Ctz_”. I ,)
tti14.1VeJ' f
!►'ta.n r1
. 0
�
o
0
T *y.•4.9zw • `'•�
•
6. DHHS SIGNATURE
.1 �I'..
^-�•
B
�Y�
droved for
Disapproved.
v
..' bedrooms.
Conditional approval for
••. g.AYNE N•i ON e Q
• CE -4488 .° f.A,, ,.A,,a
1et? ig
4 kvt, • • s., •. • g LI `cc$1
' bedrooms, with the following stipulations:
Additional Comments
N-
lei w _ .,• r.,.ftYJrr .:n, w ,;�•.... il<l •I lr.+", n... ^,+ ^v s: },{ -},,, Sd, 14• t.
r-...,ri a Municipan of Anchorage Department of Healthand Human Services (DHHS) issues Health Authority
:.'moi,. Approval,Cer ificates based only upon the representations given in paragraph 5 above by an independent
.� "' professfQrtat"erigineer registered in the State of Alaska: The DHHS does this as a courtesy to purchasers of homes
^",., '' 7.; find their lending institutions in orderto'satisfy certainfederal and state requirements. Employees of DHHS do not
�f'.•conduct.inspections or Aanalyze' data before a. certificate Is issued. The Municipality, of, Anchorage is not
' “I , :. ig',"..i': I.IMY..r - Glt 1.111+.M4I II 1(0.W L • . . ..5. ..
responsible for errors or omissions in the professional engineer's work.
Date
CAUTION
72-025 (Rev. 1/91) Back MOA 821
•
Municipality of Anchorage
Department of Health & Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: 2'f p Blcir zz) /'lcleSkt Parcel I D
Sit, &c -d. #*
074--0ZZ—/'
A. WELL DATA
Well type PrZ l✓*TE If A, B, or C, attach ADEC letter. ADEC water system number
/ f r 7:)r-
,
�r.� I
Log present (Y/N) � Date completed ©=/0778. Driller ,/71 7/ �` l)rc
Total depth /0 6 Cased to Casing height z--/
Sanitary seal (Y/N)
Wires properly protected (Y/N)
FROM WELL LOG AT INSPECTION
Date of test 0 /c)7/ 8 `fT //3 //75
l i
Static water level f Z
Well flow g p m 3.
Pump level /moo T REPoere,A rwt n.wcwl .
g p m 7_o ictect. cbw,.)
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot /1/4.-- ; On adjacent lots /k//t-
Absorption field on lot /V/ 41. ; On adjacent lots 41/ if
Public sewer main 2 ". / / Public sewer manhole/cleanout Ma -n /to /e- g6 /
Public sewer service line2 Petroleum tank
ND n/,�
WATER SAMPLE RESULTS:
Nitrate
cc' , 3//
Coliform
Date of sample:
PTIC/HOLDING TANK DATA
Date insta
a• /0 m IS– Other bacteria
Collected by. 1./"'
Tank size Compartments
Cleanouts (Y/N)
High water alarm (Y/N)
Date of pumping
�z
r r, E 'o
Foundation cleanout (Y/N) Depression (Y/N71
Alarm tested (Y/N) < >
ti
SEPARATION DISTANCES FROM SEPTIC/HOLDING TA
C
o"'
z
Well(s) on lot On adjacent lots • undation
To property line Absorption field Water main/sery - ine
Surface water/drainage
72-026 (Rev. 3/91) Front MOA 21
CONTINUED ON BACK PAG
. LIFT STATION
D. e installed Manufacturer
Size in •allons Manhole/Access (Y/N)
Vent (Y/N) "Pump on" level at "Pump off" level at
High water alar evel Cycles tested
Meets MOA electrica odes (Y/N)
SEPARATION DISTANCE ' OM LIFT STATION TO:
Well on lot On adjacent lots rface water
D. ABSORPTION FIELD DATA
Date installed oil rating System type
Length Width -vel ickness Total depth
Total absorption area leanouts present (Y/N)
Depression over field (Y/N) ti gate of adequacy test
Results (pass/fail) for bedrooms
Peroxide treatment (past 12 months) /N) yes, give date
SEPARATION DISTANCE ' OM ABSORPTION FIELD TO:
Well on lot On adjacent lots Prope line
To building fou ation To existing or abandoned system o of
On adjace ots
Surf
Cutbank Water main/service line
water Driveway, parking/vehicle storage area
urtain drain
E. ENGINEER'S CERTIFICATION
1 certify that I have checked, verified, or conformed to all MOA and HAA guidelines in,fI ct o tge date of this inspection.
i Al 7 ph
a�;): In 1A \\\
0,4.... .. ,
Signature
Engineer's Name W4Yit/C deN/>.5/2vA-1
Date 2/f3/9-5
"fro
NENC ON 0
CE -4483
s
0°
o°.s
0 °
° 0
0...0.0
... 0 ° 0 'E�' 4-7
HAA Fee $ 260 •
Date of Payment ("2//./
Receipt Number
72-026 (Rev. 3/91) Back MOA 21
Waiver Fee. $
Date of Payment c%c// �✓�'
Receipt Number 06?) - (i/
S
CT&E Environmental Services Inc
Laboratory Division r
CTLE Ref.$
Matrix
Client Sample ID
Client Name
Ordered By
Project Name
Project$
PWSID
95.3751-1
WATER
L8 BLK22 ALYESKA S/D $3 -DOWNSTAIRS BATH
Laboratory Analysis Report
FLATTOP TECHNICAL SRV
TED MOORE
DA
WORK Order
Printed Date
Collected Date
Received Date
17652
09/06/95
09/01/95
09/01/95
at
15:26
11:30
15:10
Technical Director STEPHEN C. EDE
Released By..., -744 -
hrs.
hrs.
hrs.
Sample Remarks: SAMPLE COLLECTED BY: T.F. MOORE.
Parameter
QC
Results Qual Units Method
Allowable Ext.
Limits Date
Anal
Date Init
Nitrate -N
0.10 U mg/L EPA 353.2
10.
09/02/95 BMW
• See Special Instructions Above
e• See Sample Remarks Above
Q . Undetected, Reported value is the practical quantification limit.
D'. Secondary dilution.
tJA . Unavailable
NA . Not Analyzed
LT . Less Than
GT . Greater Than
200 W. Potter Drive, Anchorage, AK 99518-1605 — Tel: (907) 562-2343 Fax: (907) 561-5301
ENVIRONMENTAL FACILITIES IN ALASKA. CALIFORNIA. FLORIDA. ILLINOIS, MARYLAND, MICHIGAN. MISSOURI, NEW JERSEY, OHIO. WEST VIRGINIA
Client:
WELL FLOW TEST DATA
�
112- wt's i (-
Peninsula Engineering
440 W. Benson Blvd.
561-5107,561-5077 FAX
Date of test: o(/3//15
Location of well (legal) 4071 3 B/cc/ zZ-�, /y25kC b�
5cc. !k1� i 3
Depth of well: /t'(, r Casing depth: 2.0 Tested by: lamer Qtrsai✓
Date drilling completed:
TEST DATA:
4Driller: /e 1'i
Clock
Time
Depth to
Water (ft
Drawdown
(ft)
Pumping
Rate (gpm)
Remarks
//`:,3v
/2.
0
0
Rr,`o.- 7C Ye.vt 5711t.r"7
//:3f..5-
/2-•
o
4-
ge....vci, --9 w%eiV 'f -,e -f 4eagt,v
11 t5o
/9
7
4
4,-s C, -•2f- .,/o�v.
iz:off
2d
/4
cdr-a.w dot, -s-lab /, c/
/ : zo
^2--B
/ 4
-4-
s¢�, + 424,a
/ z ; 36-
7_15?
/6
4
e( cr
/7_.'6P
2.-6
/ 4
3.7
-742/c, u r c cfu.c_. -L s /t' LI I'/
�d
: 05-
-2-8
/ d
3- 3
� on. s `iaw-f --14'/0“)c -Q w cin 1.;:N.
/ . Zo
7-7
/5
3- 3
/ `36
3Z
20
3.3
}} `�
V'urvKP cle,/i,v.1 Go.%411n,H1 a.`� I.srr1/1✓
/ . 60
30
/8
3.3
f..., -le,- vqv/s . 2),a d(©a ,r v&ries
Z : o6
3 3
z./
3.3
.4?-' f '.a gee' AO Z $ ' 40 33' cis pump cy.4S
Z : Zo
a3
Z-/
3.3
ci.-a..wdvu•.is, 2/b��.S '/v 33f
Z $ 36
33
Z./
3,3
%Zed
a, .w1 a c4.sT b€.4re.. p4.M. r -ki.imirr.
2. '. 5-e)
2$
/4
3,3
Re_a-cr'- j 5
be.Are- pa.rnp st r ,:
3 : os
3/
/ 7
:3
*Nik,yt
d.-atvdois3 /'- 3E)'
3 : 2.0
31
ZZ-
3.3
'4 3-2-i- 3 Y-'
-3 : 3'J
-32.-
Z©
3. 3
..E. -cd -f'/c 7 67'
3 r.-1-0
ZS`
13
to
3 :4.5-
Z/
9
0
( /
�'.1iv?c c �.QvC� 1 re cover) Al
"3 : 5-0
/ 9
7
0
r,f i ci /A `to O r i ea e_.-/
1,1s4
MISC. DATA: Casing height :_ Z/ it Sanitary seal? ! eeS
Wires in conduit YaS Grading 0.K? Ye- 5
Date bacteria & nitrate samples collected: 0//3//95-
RESULTS:
//3//95-
RESULTS: Well currently produces: .3.3 GPM with a Z0,4vE Drawdown
FLOW RATE NOT GUARANTEED -SUBSEQUENT VARIATIONS CAN OCCUR!
A67' e :
Ak
CT&E Ref.#
Client Sample ID
Matrix
Client Name
Ordered By
Project Name
Project#
PWSID
CT&E Environmental Services Inc.
Laboratory Division P.iiioiiiiiiiiiiiiisiAwdmi iii FArA won 2,4i®®iir�
95.0409-1 Laboratory Analysis Report
L8 BLK22 ALYESKA #3
WATER
PENINSULA ENGINEERING
UA
WORK Order
Printed Date
Collected Date
Received Date
12345
02/06/95
01/31/95
02/01/95
@ 14:16
@ 12:15
@ 08:30
Technical Director STEPHEN C. EDE
hrs.
hrs.
hrs.
Released By_
Sample Remarks: SAMPLE COLLECTED BY: W. HENDERSON.
QC
Parameter Results Qual Units
Method
Allowable
Limits
Ext.
Date
Anal
Date
Init
Nitrate -N
0.10 U mg/L
EPA 353.2
10. 02/01/95 CMR
* See Special Instructions Above
** See Sample Remarks Above
>3'= Undetected, Reported value is the practical quantification limit.
= Secondary dilution.
UA =
NA =
LT =
GT =
Unavailable
Not Analyzed
Less Than
Greater Than
200 W. Potter Drive, Anchorage, AK 99518-1605 — Tel: (907) 562-2343 Fax: (907) 561-5301
ENVIRONMENTAL FACILITIES IN ALASKA, CALIFORNIA, FLORIDA, ILLINOIS, MARYLAND, MICHIGAN, MISSOURI, NEW JERSEY, OHIO, WEST VIRGINIA
MUNICIPALITY OF ANCHORAGE
MEMORANDUM
Date: March 15, 1995
To: DHHS Accounting & Budget
From: On -Site Services, DHHS
Subject: Request for Refund - Account #2570-9426
Please make the necessary arrangements for the following refund. This property does not
qualify for the waiver of 21.1 feet from the well to the public sewer line. Please refund the
$920.00 waiver fee and send it to the address listed below.
Peninsula Engineering
Attn: Wayne Henderson
440 West Benson Blvd, Suite 206
Anchorage, AK 99503
Recept # 00685
Amount: $920.00
Account # 2570-9426
Legal Property Description: Lot 8, Block 22, Alyeska Subdivision Addition #3
W6u4-
Kathy Bouschor
On -Site Services
cc: File
MUNICIPALITY OF ANCHORAt.:
Department of Health and Human Services
On-site Services Section
Waiver Review Worksheet
WR# WR950006 PID# 076-022-15 HA# HA950051 Permit #
Date Received: 2-13-95
Legal Description: Lt 8, Blk 22, Alyeska #3
Engineer: B. Wayne Henderson
440 W. Benson Blvd.
Anchorage, AK 99503
Applicant: Doyle Miller
Waiver Requested: Well to Public Sewer Line - 21.1'
Well to Public Sewer Manhole - 96'
Criteria: 1. Geology: Points:
A. Water Table
B. Soil Sorption
C. Permeability
D. Water Table Gradient
E. Horizontal Separation
TOTAL:
2. Special Conditions:
3. Other:
Waiver is Granted: Waiver is NOT Granted:
x
List Conditions or Reasons for above: SEF AtITACREQ GETTER ATTED
/1/tR%/( 1, /997 BY Tim cAO5 . P. f quer To BE PRP-it/50,e°
Date: 1.1-95 By:
Rec #: 00685 (659)
Amount: $920.00
ame of eifewer ` 1
Date Paid:
02-13-95
S` off}. D. C. S.
DATER 7-4.9LE
SEw FIP L/4'E DEnne 8'
/8 ' (, $h.d (&EtW#cn)
q .2
X=.23t /
5011. Soiemriov
$ 4wO Y 6)?p vEL /. S
5AAioY 6F21evEL
wgre' TPt5LE 6/if}P/,ENT
86dnout si.oPe ld%
}/OR/Ze"ML SEPAR 61T/oN
21'.
2i
8'.: /o'
1'014/TS
/.2
6.0
6/p,bj2 TorAL
/0.3
W
z
W�
M
z
Z 0
0
SCALE= NOT TO SCALE
EXISTING GROUND SURFACE
" T= EXISTING PffLE55 ADAPTER 'e
110 FT. TOP OF 4 IN. SLEEVE •
°' . ► h ►'
//
qo~y
/ v
`
/i....to-7---1 /
CENTERING GLADES TYP. C10 FT. O.C.
\
\
\
SAV; SLOT BOTTOM
15 FT.
\
w
.t9
O
E>
'
\/\
/
4 IN. FLUSH JOINT THREADED SOH. 40
PVC WELL CASING CASTM F480-81)
MONTORNG PIPE C4.50 K 0.D. X 4.026 N. 1
SOLID FROM 10 FT. TO 90 FT.. SLOTTE;
FROM 90 FT. TO 106 FT. _.
(/
>>
[BENTONITE SLURRY PLACED BY` TREMIE Mf
LCM AT 100# BENTONITE TO 18 GAL. OF W
\
\
\
HAYES MODEL 4—KM FORMATION PACKER
C2 EA. SET AT 60 FT. + 65 FT.)
\,
A
'
O
0
d a '
i \//\///\�//��//��//v//.
\0.-\ \\\ \\\ \\\ \\\ \\\
4'0 .1 : moie2 : AV <
k, ..,(/
.„., /4-/ /
t� Q
/\/\/\/\/\/
N
14-
�-1
a
'a
ao,
• 13/(V21010 \\\�\\/�\\,\\�
aNV aNVs /\/� NOO?JQ39 CUIOs. /�/
. o• /, ,,,,,,,,,,,\,/,,,,/,..4 �/, /i
ao
a/\//\//\//\//\//\/•
/�
c0
Lo
i\moi\moi\\i\\i\moi\�iS9._
r
212/VM /M n
io021a39 a321nioV21.4
11 k 1 1 1
PROPOSED
BOTTOM OF WELL
•
'\ t =" g
.... \ - \ \ e +06‘ no
- \ \ ,
q 60
Sheet 24 of 29
LOT
! NO.
5
'
B
NO.
22
SADDLE 9
STATION
5+24.5
6
22
6 + 22.5
7
22
6 + 84.7
8
22
7 + 64
9
22
$ + 76
10
22
9 + 99
11
22
11 + 44
12
22
12 + 04
1
21
3+30.5
2
21
.2 + 70
12
21
11 + 58
3
L
2.1
11 + 0 5___�
14
_ 21
10 + 54
4
20
. 3 + 26.5
5
20
2+70
tq)
W
MANHOLE CONDITION — No. & Depth/ .0..1.) -7f„ rI
MANHOLE CONDITION — No. & Depth ‘ig -(5i) -7 y �f
•
L
44 k
O
a�
Z
❑ PAVED STREET GRAVEL STREET ❑ EASEMENT _ SAMPLE TAKEN? ❑ YES 'mss} NO
REMARKS
)
If)
o
EttN
C7
1
W
O
Q
I II
Q��
1
w
CC
MI. No. M.H. No.
• MUNICIPALITY OF ANCHORAGE
f t► DEPARTMENT OF ENTERPRISE ACTIVITIES-
-
SEWER UTILITY
• TV INSPECTION REPORT
Water Temperature
DATE
REPAIRED
DESCRIPTION OF DEFECT
I
:
k
‘k
P\
l
�
tc'kw;t
:‘1
,k
Ci
Type of Pipe
Depth of Flow t/ f'
Pg. otithi
PHOTO
NUMBER
Quadrant
1 2 3 4
DISTANCE
READING
14
tq)
>Peg (6L/t) S90—t£
NOTES
'6
‘
DISTANCE
READING
Quadrant
1 2 3 4
,
ell
=
1
,
PHOTO
NUMBER
r
9f-.1
Nik
c,.
,
(b/ ;•/W ,o-v/7/oi) fr
k
...
11
,
tN
r•.•
Q)
.,‘
'
•
4Ik
ZOO /5 4PPIOXIA14-7E POber 41,0
-.e..te
I • - q
0N
ri
,
'.
. ,
...4
1•
.
• %,
- • - DESCRIPTION OF DEFECT
.
\341,
L'I‘l
VI
•
1
•
DATE
REPAIRED
Ilt
.
N
...
t
"I
,
'
.
›
=
tn
DATE JACKET MADE OUT
DATE INSTALLED SIZE OF 119
M.H.11 / PAVEMENT,ta
EASEMENT_
TYPE OF PIPE otntctloll ,,0
�j/
SIZE OF PIPE ;J OF FLOW w v -
GRID K 77 gc
TYPE #1 ALLEY,
SIZE OF M.II. STREET
SUB, INpPECTOR / PI
DEPTH OF M.H. / 7 DEPTII OF F,t OW !$ �PanIf%1
tyrt uP hey
SIZE or7sr1
GRADE RINGS
LADDER RUNGS 3 ti YES
4., 6"
NO
NOTEs170,g/
TYPE OF PI�i
SIZE OF PtPC
TYPE OF PIPE
SIZE OP PIPE •
INSPECTED DATE COMMENTS
/f r
71'.�ti llE 11!
'�J
h
DATE JACKET MADE OUT
DATE INSTALLED SIZE OF LID e14-.
M.H.N Ai PAVEMENT
GRID IS 77 57 EASEMENT
TYPE r{ ALLEY
SIZE OF M.11 � 0 STREETX
SUB. INpPECTOII f3�/�/5
r
DEPTH OF M.H. 75/7DEPTII OF FLOW / aczoi
GRADE RINGS : 2" 4" ....L— s"
LADDER 11UNGS ;YES SI NO O•
N OTE: r H// l l %a '
,W 'w G/3�di"
3,•,,,,,. IIT
TYPE OF PIPE
SIZE OF PIPE
maw two zfre
OF FLOW (I
TYPE OF 11Pr r
Iit or PTP!
TYPE OF PIPE -
SIZE OF PIPC
TYPE OF PIPE _
SIZE OF PIPE':
INSPECTED DATE COMMENTS
dit
n
1
4 MAINTENANCE DIVISION
A
E• P
0 U
I W
as
.4
w
u
H
H
V C•
Z w
W
0 0
w>.
•TW
. W
0 4
H
0
H
0
W
as
o.
Z
W
3
/;/4::/,;/ $;T4i
'///
REASON FOR
EMERGENCY
EMPLOYEE NAME A4Z REFUSING OVERTIME /477CJ PROJECT/JOB
i
1
sN)
.„1
Cr
-N1
ti
)
w
Z
H
H
4
0
M_
\r
Ws
w
H
4
0
TOTAL HOUR
SUPERINTENDENT:
PS
w
0
tnH
0
W
0
Ix
a
DISAPPROVED
as
0
W
0
oa
a
DISAPPROVED
a0
rIVAO 1ddl
12
0
Y
1
•
NM
W
5
w
w
s
5
w
vi
F '
2 C 14
y W w
SUPERVISOR
APPROVED
as
w
DIVISION
DISAPPROVED
0 0
CHUCK EGGENER EGRS. ID:907-349-1015 FEB 14'96 13:22 No.010 P.01
CHUCK EGGENER CONSULTING ENGINEERS
FACSIMILE COVER SHEET
VOICE ��PHONE: (907) 349-1010
TO: .�.1la1 C. /ss
FROM:
PAX .343-4784
Chuck Eggcner Consulting Engineers
P.Q. Box 232946
Anchorage,sAlaska 99523-2946 C�
Contact: v
FACSIMILE: (907) 349-1015
PAGE' / of
DATE: 2//4/96
livasev
_2u5r 1zo,ti —
/�ccrz. cvezc.
,Car,, Eck zz, 4L''95J,3
************sack**************************
MESSAGE:
Ifracovsz, fiNo �� 8,Vd otC / j ,Cf%tt%!/11 o 5diewbo,
4.40450%)l.�l lG' TIO�c%5' TD i f " /%llLlrc C1 ZG . fv
19-0 tp?ezitz 74 Awe- Awalpiamalus To ooripAi
CPE?.G 2&P1i)5 /Vi P40/1( Vali l?grxidy
T 22, W6 tea l s /11,477-4/44. Sl ip/C477Oty
eozz ciOt) v/ Ts , .27f yo ' wove
LIICG� m7P/TZPvie14. ivfig 2n4 -rt W eavewor wak,
26-91/6-W, 19467W doir.)r r 416- t¢T 39-/o/
MEMO
To: Keven Kleweno
From: James Barndt
Subject: Waivers for Sewer line and Well separation distances in Girdwood
Date: December 5, 1995
There were many waivers found for sewer line and well separation distances along the Alyeska
Road in the area you requested. These waivers were found from the records in the office only,
and a brief summary of each is given below:
Lot 11 of U.S.S. 3043 Private well to sewer separation distance waived to 65ft.
Reason for granting waiver: "specially constructed" sewer
Lot 131, 13G, and 13H of U.S.S. 3043 Class C well to sewer separation distance waived to 90ft.
Reason for granting waiver : Not given
Lot 12A Ramstad Subdivision Private well to sewer separation distance waived to 63ft..
Reason for granting waiver: Special construction was done (outlined in attached folder).
Lot 13A of U.S.S. 3043 Private well to sewer separation distance waived to 53ft.
Reason for granting waiver: Special construction was done (outlined in attached folder).
Lot 13B1 of U.S.S. 3043 Private well to sewer separation distance waived to 93ft.
Reason for granting waiver: Special construction was done (outlined in attached folder).
Lot 13F of U.S.S. 3043 Private well to sewer separation distance waived to 47ft. and 65ft.
Reason for granting waiver: Special construction was done (outlined in attached folder).
Lot 71 of U.S.S. 3042 Class C well to sewer separation distance waived to 43ft. and 121ft.
Reason for granting waiver: Special construction was done (outlined in attached folder).
Lot 103-2 of Ellis Green Sub. Private well to sewer separation distance waived to 77ft.
Reason for granting waiver: Special construction was done (outlined in attached folder).
Lot 103-4 of Ellis Green Sub. Private well to sewer separation distance waived to 65ft. & 77 ft.
Reason for granting waiver: Special construction was done (outlined in attached folder).
Lot 13 part 6 of U.S.S. 3043 Private well to sewer separation distance waived to 53 ft.
Reason for granting waiver: Specially constructed sewer line.
Lot 25 of U.S.S. 3043 Four waivers were granted on this property. This looks to be a Class C
well that has been changed to a Class B well:
Well to manhole distance waived to 168ft.
Well to sewer line along road, distance waived to 165ft.
Well to sewer line along the southwest property line, distance waived to 125ft.
Well to sewer line along the northeast property line, distance waived to 175ft.
Reason for granting waiver: Special construction was done (outlined in attached folder).
Lot 3 of 65A, U.S.S. 3044 Class C well to Community Sewer distance waived to 35ft.
Reason for granting waiver: Location of well in strata, and a stipulation that a Total
Coliform Bacteria test be submitted semi-annually to the department.
Lot 68-1 of U.S.S. 3043 Class C well to sewer line separation waived to 66ft. and well to privy
Keven Kleweno
Page 2
December 5, 1995
separation waived to 88ft.
Reason for granting waiver: Waiver only valid for 2 -bedroom duplex residence only.
Snow Valley Subdivision. Well serves 8 lots, given a waiver for well to sewer line separation
distance of 140ft.
Reason for granting waiver: Not given, but possible grandfather clause.
Lot 102A, 102B, and 102C U.S.S. 3042 Well to Sewer cleanout separation distance waived to
144ft.
Reason for granting waiver: Contamination not feared in this case.
Copies of the above waivers and other information pertaining to them can be found in the
attached folder. If there is any questions, please don't hesitate to ask.
The Alaska Department of Environmental Conservation
AnchoragelWestern District Office Telephone: (907)-269-7505
555 Cordova Street Fax (907)-269-7506
Anchorage, Alaska 99501
File Record (circle one:) Name: even K. Kiewer�
Telephone conversation
Meeting notes
Notes to file
Site visit notes
Date: l/3//g6
Present:
ce.( abl c.
17p6,),
ski, s) + �`�C►)
50 s)
S�6
/ q,
ROMAC
pig
INDUSTRIES,
INC.
INA 1-800-426-9341
N
O`
co
V'
0
Q
C/
o'
.L,
0ccs'
2
RNP • March 1, 1995
Style "516" Bell Joint Leak Clamps
(For use on Cast Iron, Ductile Iron & AWWA C-900 PVC Pipe)
Bell and Spigot Ring: Ductile iron per
ASTM A 536, Grade 65-45-12.
Gasket: Virgin SBR per ASTM D 2000 MBA
710, compounded for water and sewer service.
Other compounds available on request.
Bolts: Trackhead, UNC rolled thread, high
strength, low alloy steel per AWWA C111.
Nuts: UNC rolled thread, heavy hex, high
strength, low alloy steel per AWWA C111,
with black finish.
Use: Romac's 516 Bell Joint Leak Clamps
provide a fast, economical means of repairing
or preventing leaks in cast iron bells, caulked
or rubber ring joints. Our unique gasket and
ring design enables a single clamp to fit both
caulked and rubber ring joints for most classes
of cast iron and ductile iron pipe within a
nominal size. They also can be used on
AWWA C900 PVC pipe'.
6" Bell Joint Leak Clamp
Ductile iron poured
in U.S.A.
NOMINAL
PIPE SIZE
O.D. SIZES
(inches)
CATALOG
NUMBER
BOLTS
APPROX.
WEIGHT (lbs.)
NUMBER
DIA. x LENGTH
4"
4.80 & 5.00
516 - 5.00
4
5/8" X 10 1/2"
17 #
6"
6.90&7.10
516-7.10
4
5/8"x101/2"
19#
8"
9.05 & 9.30
516-9.30
6
5/8"x101/2"
29 #
10"
11.10&11.40
516-11.402
8
5/e"x14"
58#
12"
13.20, 13.50 & 13.65
516 - 13.65 2
8
5/8" x 17"
100 #
14"
15.30&15.65
516-15.652
8
5/8"x17"
110#
To Order: Specify catalog number.
Note: BJLC can be provided with double
gasket and spigot halves for repairs on in-
line couplings. Please provide coupling
O.D. and length. All prices on application.
' Special length bolts are available for D.I.
sized PVC pipe with extended bells.
Please provide bell length when ordering.
Larger sizes of fabricated steel BJLC
available P.O.A.
2 The 10", 12" and 14" sizes have stainless
steel armors molded into the gasket to
bridge the gap between castings.
1-18
01/04/96 11:54
$9078494686
BAUGH CONST ANCH 121001/001
96-01-05 08:02 IN
Please Deliver FAX To: Laura, Onsite Services, DHHS 343-4786
January 4, 1996
Howard Holten, Chair
Anchorage Onsite Water & Wastewater Review Board
Department of Health and Human Services
Muncipality of Anchorage
RE: Lot 8, Blk. 22, Alyeska Subdivision Add #3 Well-AWWU Sewer Separation Waiver
Dear Mr. Holten and Board Members:
We respectfully request a continuance of the Board review of our waiver request for
separation distance between our well and the AWWU sewer. The completion oFour
engineering analysis has been delayed during the Christmas Holidays.
We will contact Mr. Cross to reschedule a future meeti 'me with the Board. Thank
you for your consideration of this request.
cc: Jim Cross
Sincerel
Doyle ler (34 -1531 wk.)
Christy Miller (269-4567 wk.)
/J.1/C6e71. L D<UT 7ij
*/4- 7/6/14!ir-Pit'..- ,114106: e0-46 04)12t-4, Pit- 1 //OS -
>,111(14 Poly c$x r k5e-z, , Y i Z7E(. 45m4Lk
•�5‘'- 2
-5GC?Y 5A)2y G/ •.
41/
Fiekre,S77
crMaX, T Le• - wig/ ,sore/&- 77/-&---- 04'TW4 .
/5 56' (a10,4t D15 re e) I -c.c.s -y
!WO P L477N6 412e . 743 (r7?Hi1 v?- -
L4: /'DI GT �lfi�t
4 �.� cQ 5-4; USE 5.4 pi
,S / 3/77 54%),D`/ GRIFVEZ. 0/.5 "7 )
5-1/ 54tio aerv.oe 6.0 n
5015) f5/(6•o) 576
670
0 tivioteitify
5'%5/LTV s 44)DY , -1-- (/ 5 f3)
5/' „so4,? tEP, oCX (3.0 Pi)
/V V /ed¢ -W.0s -- Gk= /eve' Scopes
iO win uJ6-4. efr /Oro o/G-Atoi1
•
osr 5:4 .P73
vim- 2.? /73
G Z Z76/C ,/ZOF/
L07`8 eeocie Z2 4,Lyt-51479. ,504D
77 /AD 4 p/770
Roo
772,Ebeti -1
77o,()
--6/4/46
wf—
. 0
0/ef
a/95
toad -
v
s7*T7C
Lg.-VC L.
Z
D� CVs 51 LTY t'huD y
> 25% se61-) ...
e)477vn of CA -51 AJc
G,QgVO1fr ,
7E-61 Pe pD/u6
Mee flu
e„ )//1 5a,- 7)0 p3 .
w T AT 3.6
PLUME -- -�,
/5
7t 6t 7 P/ mE"
45-
----` L/V ,Oc,A
00/
,vsr Mole' 73o60A)
sGD,o�-
LOT &, hoc./G 22 "WW1 - so./5.0
2T7-/ 150v { 5 6-e770 /0AT Pir &Jr - L
"2ox 5( ~rf /t'f _ I/ (v i )
ANCHORAGE WATER & WASTEWAIIR UTILITY
Aloe325 East 94th Court
Anchorage, Alaska 99515-2111
Telephone: (907) 267-4500
Fax: (907) 344-7325
Rick Mystrom,
Mayor
December 14, 1995
Mr. Doyle Miller
Anchorage, Ak
LOT 8, BLOCK 22, ALYESKA THIRD ADDITION
,I
Owned by the
Municipality of Anchorage
The ductile iron pipe fronting your property at Lot 8, Block 22, Alyeska Subdivision Third
Addition was cleaned in June of 1995 as part of the Utility's preventive maintenance
program. At your request, it was re -inspected November 30, 1995. This sewer main was
found to be in excellent condition on both occasions and we don't anticipate any problems
in the foreseeable future.
If I can be of any further help, please feel free to call me at 267-4506.
ROBERT G. F ' E, Manager
Operations & Maintenance Division
Anchorage Water & Wastewater Utility
m:\fuge\letter\m i I ler.doc
ta�rer �t
an Far
11.1 asawS000r)
GREY SILTY GRAVELLY SAND (SR)
ver dense. Moist
2x
20
LOG OF GORING 52
yr EO M"' R• Helier Stew Aneor
•
Merinos 3195 Data 411/77
i
1
10-
15
20
'P010Y/SATZ7)
AK moornAre
119 /Cr
GREY VERY SILTY SANDY GRAVEL (GM)
very dense. exist. with
cobbles and boulders
�7.W•era vS,Fccr/
LOG OF BORING 53
E44140it R' Hn11ew Ston Rune,-
co▪ o
uner
o▪ ao Elevation 233.4 Data4 J, f 77
O GREY SANDY GRAVEL (GP)
BROWN -GREY SILTt SANDY f Wt I
GRAVEL (GM) c BROWN PERT (PT)
medium dense. wet. soft. wet
...r% Row rnhhlee
15
20
Mater Level 4/4/77
Becowlnt blue -grey. dense.
saturated. with cobbles and
boulders at 3.5
pis aowS/faorl
bece.ine Breen -brown. medium
dense. with layers of sandy
gravel (GP -G4) at 4.5
Becoming Grey. very dense.
with layers of cobbles and
boulders at 6.5
5-
*cM vO,) 10
Drilling recusal at 108
15•
20
soft. wet
L
J
1
GREY SWALE
switch to solid flight
auger with rock bit. No
change in drilling to 4.0
Moved 4.5'West - sane
conditions
No free water observed
very dense. satu
10 :MSE with cobbles and
/3S.7X PASS/NO.2A
so• 01.060/50001"
15
20
LIGHT GREY SILTY SA
very dense. .ois
with cobbles and
//23 B[OrVS#3w77
LOG OF 001
Eguipment
6• Se11A F
• Elevation 332.4 c
0
10-
I5
20
GREY SANDY GRAVEL
-En.lv2 ^-4T (DT )» v
BRO!'M SA!DY SILT ('
GREY SHALE
Note: Boring inten
probe for ro
BASIS OF
VERTICAL CONTRO'.
—
DATE -
IT
DATE
AT
r
w.,,a..w. Moe.
AM/LT
SAN ERR
•-----Ej11111
..sou et s. o•.
IMAM MEI
'-1-17-110
.LATER
D a
REVISED FOR 1990 CONTRACT.
ace...
3-25-n
DM
GAS
2- 1 - 79
.6-29-79
GK
CK
REVESED FOR 1979 C P4 TRIICTK�N
TEL ANOE
CHANGED YULE SUL DUE 101971
REVISIONS
Cw1c1"C
4-25-77
BOK
ELECTNtlC
DATE
6T
1
21 \ \.
\
Aid
\ 13
e�
11
452
Sl I
,1
345.1
18
; 1
•
6 *354
Sh• et
/1
r
•
0
�-5T oLE -l7
at�a.ctie�
CbL
SEWER SEKVICE SWI:+
SWING TIE NO. 1
DESCRIPTION
5 + 24.5 SE to 19" Pine
6 + 22.5 C L MH 6.17
7 Y2 6 + 84.7 N to 19 Pine
8 22 7 + 64 C L 111 618
9 Y2 , 8 + 76 • E to Power Pole
10 22 9 + 99 C L MB 619
11 + 44 • NW Corner House
Nouse
3/ / ' 11 22
12 22 112+04
1 21 3 + 30.5
2 21 2 + 70
12 21 11 + 58
13 21 11 + 05
4
21 310 14 20 13 + 26.5
4
NE Corner
SW Corner House L2 821
NW Corner House
N to Power Pole
SW Corner House
SW Corner Nouse
C/L NH 621
L11 822
5 20 2 + 70 NUI Corner House
22 4 + 61.5 NW Corner Houue
30
300
SIM EL. 31676 3/7. /
W. INV. 309.23
S. INV. 3099, 309.9
29
RIM EL 303* 3o'..,2,
W. I N V. 296.06
E. INV. $96 -•?4 -291./9
�»c
1-4
0
743
EXIST.
SOUTH t
NORTH t ---1
FAX TRANSMITTAL SHEET
Date: lit fr Time: 2 : IS- 11) Total Pages:
To: 1) i%yLE' r#(/ L" L -
Company: 8
Fax Number: 3 '4/ q� - �� Phone Number: '54/ " is 3 '
From:
ji *1 CoSS
Company: %'tel n /4- PM/S.
Fax Number: 343- VI D Phone Number: t.i3 - Y560
Comments:
Horizontal Separation Distance Waiver Calculation
Lot 8, Block 22, Alyeska Subdivision #3
Parcel I.D. 076-022015
Doyle and Cristie Miller
1. Basic Information.
This waiver was requested for a horizontal separation distance of 21.1 feet from a
private well to a public sewer line. The well was installed in 1984. The sewer line
was constructed in 1979. The horizontal separation distance required at the time of
the well installation was 75 feet.
2. Well Data.
The well was drilled on 5/7/84 to a total depth of 106 feet. The static water level in
the well casing on 1/31/95 was 12 ft.
3. ADEC Point Calculation.
Top of bedrock at 18 ft.
Total depth of 106 ft.
Static water level on 1/31/95 was 12 ft.
a. Water Table (Static Water Level in Well at 12 ft.) 1.5 pt.
b. Soil Type (Sand and Gravel - use sand value for no clay present) 1.5 pt.
c. Permeability (Sand and Gravel - use value for fine sand, for won't
qualify for next highest value of soil with perc rate > 50 min./inch.) 1.5 pt.
d. Gradient (use +5%) 4.5 pt.
e. Horizontal separation (use 21 feet.) 0.6 pt
Total points awarded 9.6 pt.
Points required to award waiver per guidelines is 16. Deficiency is 6.4 points, or
40% of total points required. Extenuating circumstances are not deemed to be
worth 40% of waiver value. Waiver denied.
/ MEMORANDUM State of Alaska
TO: District Office Engineers
FROM: Bruce Erickson
District Office C 5ordinator
DATE:
FILE NO:
TELEPHONE NO:
SUBJECT:
January 3, 1985
Waivers
274-2533
Separation Distance
Waiver Guidelines
for SCRO
Since many of the engineering firms operate in two or more districts
the following guidelines for waiver requests are offered to provide
consistency and continuity during the.review process within the Region.
A. All waiver requests should be submitted by a registered engineer
in accordance with 18 AAC 80.020(e) and 18 AAC 72.021(a). Con-
sideration of exception should be referred to me.
B. The district office engineer should evaluate and sign all waiver
approvals and denials.
C. To comply with 18 AAC 80.020 and 18 AAC 72.021(a), the following
format is offered to use as a review guide in reaching a decision
as to whether a waiver will be granted in a specific instance.
It should be noted that separation waivers are specific and
unique to a site and specific set of conditions. The waiver
should in no way be alluded to as being precedent setting or
that the waiver represents a new standard for specific geographic
area or geological conditions. This guide is offered to assist
in determining if a lesser separation distance will meet the
intent of the regulation and protect public health. It is also
recommended that a short written evaluation be made in each of
the categories. If the engineering report does not address a
specific category, the worst case condition should be assumed.
1. Geological.
a) Where green or non -fractured bedrock is between the system
bottom and the water table one must consider the slope of
the rock formation with respect to the water source (i.e. does
it slope to or away from the source).
b) The attached charts may be used to assign number values to
the following geological conditions.
Distance from the sewage system bottom to groundwater
Soil sorbtion below the sewage system
Soil permeability below the'system
Water table gradiant
Horizontal separation
District 0
ffice Engineers Page 2
The sum of the above number values could equate to tne following
conditions:
0-8 Pollution is imminent from both chemical and bacteria
8-12 Contamination is unlikely from bacteria but could be
possible from chemicals or virus.
12-16 No bacteriological pollution possible but chemical
pollution possible but unlikely from household
chemicals.
Almost sure to be free from any form of contamination
from household sewage.
No contamination possible.
16-5
25-45
It should be remembered that this is only a guide but that numbers of
16 or les for a continuous source of contamination such as a leach
field sho ld not be waived, unless other 75ti4 measures are
noted or special construction techniques which can mitagate some of
the geolo ical concerns are taken. Also, where the well penetrates
bedrock c lculate the values of the soil and the vertical separation
above the bedrock only.
2. Secial Construction:
a
u
Weigh any unusual materials or constructicn techniques
sed to (medigate)geological concerns.
b) Weigh material changes, design changes or special con-
struction techniques, which allow the waiver and sill meet
the intent of the regulations. Two examples are; sealing of
septic tanks to allow waivers to holding tank separation
distances, or to harden manholes (IAW the detail shown in
attachment B) to allow manhole separation to be waived to a
sewer line separation.
3. €ther
a) Consider how much of a waiver is requested (what % of the
Separation needs to be waived)
) Consider population density in the area or lot density,
ow many square fee t/bedroom? A good density is 10,000
t2/bedroom.
C) Consider lot shape and possible structural barriers.
i) Consider population at risk, normally water sources
Serving populations greater'than 100 people should not be
slued.
BEE:clh
DISTANCE FROM THE
THE SYSTEM TO THE
WATER TABLE IN FEE
7
OTTOM OF
IGHEST
0
8
17
24
30
40
85
100
290
1000
36/
ATTACHMENT A
WATER TABLE
POINT VALUE
0
1
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
Straight line interpollation is permitted between any two values.
SOIL SORBTION
SOIL TY
PE
POINT VALUE
Clean Gavel 0
Fractured Rock 1
Course Clean Sand 1.5
Sand with Small Amounts of Clay 2.5
Silt 3.5
Clay and Sand Equal 4.5
Clay 6.0
Use the predomineltt soil type but values can be averaged for a mixture,
for example; If the soil is stratified one may average each segments per-
cent value of th whole; for example, if the vertical distance to the
water table is 10 feet and there is a total 25 feet gravel, 25 feet of
course sand, 25 eet of fractured rock and 25 feet of silt point value
would be (0.25 x 0) + (0.25 x 1.5) + (0.25 x x 1) + (0.25 x 3.5) = 1.5.
C
ATTACHMENT A Page 2
PERMEABILITY
SOIL TYPE POINT VALUE
Clay (will channel)
Silt or Sandy Clay
Clayey Sand or Soil with a Perk Rate
of 50 min/inch or higher
Fine Sand
Sandy Gravel
Fractured Rock
Course Sand (30 grit or river run)
Clean Gravel
0.0
2
3
1.5
1.0
0.9
0.4
0.0
Use the predominent soil type.
If the soil is stratified one may average each segment soil value as a
percent of the whole, for example; 100 feet to water table with 50 feet
course and and 50 feet fractured rock (.5 x 0.4) + (.5 x 0.9) = 0.65.
WATER TABLE GRADIENT
+ Slopes Away from the Water Source
Slopes Toward the Water Source
% Slope Point Value
- 60% 0
- 30% 0.3
- 20% 0.7
- 10% 1.2
- 5% 2.0
0% 2.9
+ 5% 4.5
+ 10% 6.0
+ 60% 7.0
If the gradient is not known, assume the worst case.
If there are no hydrological maps showing gradients one method which may be
used is shown:
Wt4TER -rM3c.
-sv r l�BT�@tet
jta x%vsum
DrawDvct)& Zj
-er '%14:
%4
ATTACHMENT A Page 3
HORIZONTAL SEPARATION
HORIZONTAL SEPARATION
IN FEET POINT VALUE
0 0
25
50 1
75 2
100 3
150 5
200 6
300 7
•
7
v
Linear interpollation between to point values is acceptable.
Horizontal means straight line distance to the well not the contaminent
travel distance to water table which may be greater.
DEC 07 '95 12:23 FR RADISSON BUSINESS CTR703 845 7662 TO 919073434786 P.01
Th44a.m-vet- (907) 3/3-9'5
ft:ke.gyvs.\-Ay• t7)
Sewvicg._s
00,5d.e. ....W —600.6*-021er fi'evietz
4/ye,11.(cet.34/0c/4.41.like/pi 142/4dI3 SelocA'api WO.Attlya
ZOO-kra fY)...12:YYNN5124.6.1.
Aii_oe.4.7/217.1 /000._/.47 260ctroIls
-g"kice 401E404/ re,542/004,0:7, cxce_Pfut
irkfreled;calel aoriA'reneof vge, we•Arc-- avcif ir?
'nee,* 4.4.1/11-) dro3.5 cot he. dx:m _ Occeri.T. 'For t.i..!..anvve4
04 A-Va.)/ Aftrenoc, Oec, rrir, aro* 4
. otern:e tAS he__ wai -41A.Yvi r% ,141LWI
) _
_ . OtA vs Neet.i.egst rnacs...stk.v.e..s (i4
fro.p05ece.... \Ale cindiltev' copRee14040-..4...e- hichfiv--
3octrd. . i.S.44V5ScAlAry..*
/0/414- . *Az__ culla Ice -Pcn, c.4.6 4-1:) te
- --f
resi4gdfu. Act4g-t- �y bectra; ac,ikariejeci -Fo.r
red_c.,dayIy.
k.."V;In le* 11/1 _CYR +1,42 1.3 oc4. eel. •
.01. in cesre, )
T,7 IA))
f4e.. Md41,- 6.3119*-- 6-31
R-ECEIVED
—" DEC 7 1995
Muniolpahty of Anchorage
Deptd-fealth & 171.uman Services
** TOTAL PAGE.01 **
3 /Met—
•% _
Amir
/2o/4 //O- c.--)
/ OG
/"Aze'v �� /p)
eve- 72 ,A4 /
1
SM,13770A)
620 /ENj t-ri o
451 jo- i .I < a (/r
IMMIL
3
if
A-P-A-17A31-tv D t s ,¢,tic-aF z I. I fr elbr-vv\
P 2 I vi4-rt- vo
A- D v 6 L.. t C 54-0e4_ L__ i /vE ,
cfi 5 ria-U,r9 g 4 s tw-ec_A_ e/4041- V wAj
C-6nJ S rRAl 9 -1-9 • 5 F -P A -R -A --07/9+v
c /L -t te--0 A -a- T / M E arc--
01
rc--r N 5 6 ---rt e-oJ WAS
weU1/4-
iN� w,�S OR i LL Go 041S/7-1
8
1-
ro A- re -t -74--L /L., 714- cr-F-- /0 b reer(
t5.70 /1-tvi 3r, (?W
Z EC...07v " P�
17 A)CQ 041 rE-40 -- /8
64'( r14 -.x-41 t Az.) ro �D
w4-Prele_ L‘4 57
NCEdo
3 r l % -- / i v \C -ALC- "L L
2 tArt,e /14/ii CO--N5Tg-f4Grt4j fAl c)
rA/ /IgD
NOLL) /()L -
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW950377
DESIGN ENGINEER:DUMMY COMPANY
OWNER NAME:MILLER DOYLE C & CHRISTY L
OWNER ADDRESS:1400 SHORE DRIVE
ANCHORAGE, ALASKA 99515
PARCEL ID:07602215
LEGAL DESCRIPTION:
ALYESKA #3 BLK 22 LT 8
LOT SIZE: 13500 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONSTRUCTION OF:
WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
PAGE 1 OF 1
DATE ISSUED:11/06/95
EXPIRATION DATE:11/06/96
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
THE EXIXTING WELL SHALL BE ABANDONED PROPERLY.
RECEIVED BY:
ISSUED BY:
C, b5e-a/ rn,/(A
DATE: //-&-9:j
DATE:
• r
00z
0
0rk°
°• O
71
m cn
> Z —I
r01
D OC
U) Z
> 010
rz
co 0W
o' c
o 7j
w cm
o�
c40
cyrrn
N
I
U� r
N >
(0 Z
- Z
m
Q (/)
X �
m
z
z
m
m
LANTECN
* cn O D n * O'1 I (,4 01
yZpWW
-1 V -0 n Z N
An m >7, O 2m R, - A.
W
* U) 1 -I M Z -I r
rz 1 I r S O Y
z
A
❑•o
o „
K
z al.
m
m
z
0
01
m
- n
Z
0
MUNICIPALITY OF ANCHORAGE
ENVIRONMENTAL SERVICES DIVISION
OCT 25 1995
RECEIVED
October 51, 1995
Mr. James Cross, P.E.
Program Manager
On -Site Water Quality
Dept. of Health and Human Services
Municipality of Anchorage
PO Box 196550
Anchorage, AK 99519-6650
RE: Waiver request for Lot 8, Bk. 22 Alyeska Subdivision, Addition /4.
Dear Mr. Cross:
Thank you for again agreeing to review the punitive impacts both in
financial and environmental consequences of your March 1, 1995 turn -down
of our request for a separation distance waiver for our private well.
To review the facts briefly: our 2/1/95 request was for a waiver of the
required 75' separation between the well and the public sewer line (our well
is 21.1' on the 20+% uphill slope side of the sewer); and waiver to 96' of the
required 100' separation distance between the well and the public sewer
manhole located down the hill from our well.
Our well has produced potable water for 12 years with no contamination
We understand there are basically two issues of concern to the MOA, DH&H5:
1. Safe water for the residence:
0-1
L.
Protection of the aquifer from contamination thru the AWWL1 sewer
via the well.
in response to your requested remediation to drill a new well that meets the
required setbacks, we have obtained cost estimates (copies attached) and
i lr Cross
October 31. 1995
summarized as follows:
New Well
$6,248 Site preparation/removal of old growth trees/excavation
removal of soils and native top soil; install 120' new copper.
water tubing; contour access to finish grade,
$7,250 Alpine Drilling- drill new well ($25/1f <1600';
$35/1f> 1600');Excess setup for access ; transfer pump;
abandon existing well
$ 120 MOA Permit Fees
$13,618 Estimate for new well (does not include anticipated cost. for
gabion retaining wall to retain slope est. $1500-$2000)
This alternative, with the exception of complying with standard code
practice for separation distances, does not provide additional assurances
for your concerns for adequate/safe drinking water, or protection of the
aquifer.
We propose to install a Bentonite Grout Seal for our existing well (similar
to those used in HazMat monitoring wells) to further minimize the remote
possibility of contamination of the aquifer via the existing well. Cost
estimates for this Grout and Seal proposal are as follows:
$1,500 Engineering development, review and approvals
$3,000 Alpine Grilling - Grouting and Sealing
$800-$1.000 MOA Variance Fees
$5,300 to $4,100
This alternative will need waiver from the standard code practice for
separation distances but will provide PE certified assurances for your
concerns for adequate or safe drinking water, and protection of the aquifer
We do not make this request for reconsideration of the separation distance
waiver by putting our families health, or the health of the aquifer at risk,
We believe this is the most equitable solution, providing safeguards to the
hillside environment and that of the groundwater aquifer. Your immediate
response to this request would be appreciated.
Sincerely,
Christy and Doyle Ni r 0-- -� `/ 6 7 (1
'f 6-0
cc: Bill Lamoureux and Michael Lou, ADEC
0
rt
SD
V.
Q1
Ln .b. W N F-+
004,4 00
ztntnt.r)
o (D 0, a w
'd ood G
N ft O H• H.
O r• rt rt
r.0 0 w
F✓ W n ri
rtwwt'<
• w G tr H
tn
tn Y th O (D (D
N O N N
b r• (D In hi ti
rtN (D
r•(D£'V55
o w rtH•H•
• Hrt H.
N 0 H• H.
H ort 55
N o N N d 5
rt
(D + p S 0 0
5 r
N - � H
£
Ln rt H. I-, Co
H•O0
rt H• -
7 W £ H.
P. w a G hF G
• Nrt n
H(D- O a
J0 ti H.
LF1 tl w
- rt TJ £
baroam
o (D b• til rt rt
1-F1 11 F-' n (D fD
(D H hi hi
a Cr- F -t
N < 5
0 amtTJw M
G 1i - H- =i
rt 0 0 G "i
O rta-
M
tY 0 H n
w O M
• a O CO '' J
D1bID.M-'i<
rD0aX0t~i
k (D 0 HHC-+
(D WY-JCt"
N - W ti
a Cr •
J a TJ 0 co
w tiro r�
o ti k
0100 H
- H NLO
N H co 01
• < 01
fD t'i
H• tl F
(.0 ''d0 01
`r hi 0 In
rt t>i H 01
nO •
Cc,
t1HLTJ
TJCx1
hJ r1i
tri
H roJ
H d W
< H •
trlr
ro�
yJJ
H
•
01
f"
ld
O
0
ID
0
J
to
J
01
N
01
N
to
VD
CO
N
F-• N N
C. 0 C.
000
F-+ Ni NN
Fn O O. O
O000
F-' Ni N F-
1 n 0 0 0
00Oo
F•' Ni Ni F-,
0000
O o 0 0
H.,N!NJ
01 O O
000
N r
J O O
in o 0
Ht
J O O
(n o 0
it)
r•
01
J
J
N
F. Ni Ni H
01 O 0 0
O o 0 0
F-• N N F-'
1n O O0
0 0 0 C.
F-' Ni Ni F-,
Ln OOO
O O O O
£L6T :D
0
rn
VD
J
(
N
Co01
VD
0to�troi ntba� i oaiytroi
C < C
ID w P1
ID ID m
N N F-'
J O O O
000
N N F,
J O O O
000
H
r
0
£ O
(D rt
a
H H., N F-'
N 0100
0000
n
0
w z
• 0
W
N
1-
•n CO o H
0 0 0 0
1--• N
W N O 01
O o 0 0
H N
ONO V1
0 0 o O
0
G
x
G
0
G
F., N
CO N O 01
0000
F- N
CO N O 01
0000
F, N N F,
Ni 01 OO
0000
tIl
O Ft1
w H
m0
rt
r•
fD
H+ lD
w H
N N
fn
n�
o
1•C
rt
w
H to
CD
rl-
P-
0
ni
H• 0
(D to
H 0
a0
H x
w 0
77' 0,
H.
G
• (n
H w (D
(D G £
w 0m
• 0 ti
G H
G (D
rt
• (n
H. (D 0
N O
Fi G
to ro
mti
£ H.
fD <
hi w
H rt
r• (D
G
(D
ro
to
Hrtrt
w 0 hi
• ti0
`r+ a H�
O fD
(D G
5
rt
0ro0
hi P. hi
H•
rta
O 1A
m
Water Regulations History
NJ.7JNv7
1
o
z X
W
O
X®
W®,o
� a
0
0 < 0
W Q w i
() 1r' m zw
J un Nj = LI_ O
tine
a
0
I 0 1
0 1
0 � Fl I VI 5
W� <
(.) x < cL
0 0 a a 0
0 o ci)< cr.O w �
3 U ¢ C9 c/) 3
0)
0
J
N
1--
0
J
J
JJj^
L
`Jr
0
0
LEGAL DESCRIPTION
LL
0
1--
J
m
c
0
tv
N "
-0 =6
o;a
N N
v7 c
0 O
E
0 X
a
oEc
N
vt
0
0 O
O
.t U
0
uvv
L 0' C
•o 0
W O O
F -0 N
z N
< N c
J t -
O 0 n
Q C O
O
t_ L
Q N
d N w
W C
r
yIX 0 41
a
Z
0
0
0
S
1-
co
W
>--
J
qN
m�-
so
-co
V) ID
W [ND LLJ
W [O m
Z
o �t
Z S
W _
I x
v) 0
w
z
z rn
< N
J U)
n-
I N
f u
O V)
wo
>�0
*Ln
D rn
V) o rn
om <
1= Y
Do <
CYZ<
V) W
Z LD 1
OQ
O
o
U
Qh z
rn
0)
O
z
a�
0
K)
M
-J
0)
O
UMP -115-9:5 MON 01:31 H.R.REDMOND
1L, Pedmond Co,, Inc.
General Contractor
P.O. Box 488
Glydwood, Alaska 99587
Phone (907) 783-2373
September 18, 1095
Doyle Miller
RE: Higher Terrace Lot
2 P.01
Well site preparation and new waterline installation.
1. Haul off excavation (300 YDS).
$2,288.00
2. Tree removal. 800.00
3. Install 120ft 3/4" Type K copper water tubing with new
pitless adapter and control wire. 2,560.00
4. Contour access to finish grade. 600.00
Total $6,248.00
Does not include permits.
Robert A. Redmond
FIRM
BY
PHONE
CITY DATE
BID PROPOSA,rc JOB
BID ITEM
We -a.
DIVISION ADDENDA
INCLUDES
F•
u�iceiu5v7v,z
2 fe,c,-0
e;$s i-6e�ieooda dy 0174A48
7ZIARrervet Wm, sr -r)
dn/ /s7T�z /e -da
__4770-0/65
E CLUDES PER PLANS & SPECS BY
INSTALLED FURNISHED ONLY
F. 0. B. TRUCK JOB
NEAREST RAIL
PENINSULA ENGINEERING
440 W. BENSON BLVD.
ANCHORAGE ALASKA 99503
561-5107,561-5077 FAX
February 1, 1995
Municipality of Anchorage
Health Department
PO Box 196650
825 L Street
Anchorage AK 99503
Attn.: Daniel Roth
Re: Waiver request for Lot 8 Block 22 Alyeska Subd.Addition #3.
95-E-101
Dear Dan,
RECEIVED
FEB 1 31995
Mu., ,;q.J.t;iy of Anchorage
Dept. Health & Human Services
I have performed a site investigation and well flow test along with a health authority approval for the above
reference property for the current owner Mr. Doyle Miller on 1/31/95. Please consider this a formal request
for waiver of the separation distances from the public sewer line adjacent to the property in Higher Terrace
Street right of way. The subject well is currently located 21.1' from the main 8" ductile iron sewer line and
96' from the closest manhole #618 and 6.5' west and 11.1' south of the property lines. See location maps
attached for details.
The history of this property is as follows. The sewer main was constructed in 1979 and as -built in 1980 and
the well permit was issued in 1984 and the well drilled on 05/07/84 in its present location by Hefty
Drilling. This property is located on the most southerly portion of the Alyeska subdivision on the upper
hillside of a very steep mountain side with slopes of 35-40% from the street to the rear south side of the lot.
All of the lots along this street have a very similar problem with very steep slopes which make it very
difficult if not impossible to construct a home with normal setbacks from the street and still maintain an
accessible driveway to the property and feasible utility (sewer service) to the buildings. Almost all of the
existing homes have well encroachment problems relative the sewer line for the same reason. Lots 15 and
16 of block 21 on the lower side of the street currently have approved waivers that I am aware of.
I have enclosed the location maps showing the physical location to the subject well in relation to the
surrounding lots as well as the soils logs available from the adjacent sewer line construction and a copy of
the logs from the adjacent wells along the same street on both sides. Copies of the sewer service line for the
subject installed in 1984 along with the sewer main line plan and profile have also been included for your
review. The information provide on the initial well log by the driller in 1984 is somewhat incomplete, but
my recent flow test indicates that the well draws water at a continuous rate of 3.3 gpm at a level ranging
from 28' to 34', which is well within the solid bedrock level and above the fractured rock strata. Since the
well is uphill from the sewer line with the surface ground slope and slope of the subsurface bedrock
generally very steep in this area, the possibility of contamination of the well from any possible sewer line
leaks is reduced. The steep grade of the ductile iron sewer main along the street in this area is also a
positive factor allowing little time for the effluent to stand in the pipe and thus minimize the chance of any
possible leakage with the manhole #618 being significantly lower in elevation. The water analysis tests for
the subjects well in 1989 provided by the owner and recently test results show no sign of excess
contamination, indicating that the well has been performing adequately at least since 1989
page 2
Lot 8 block 22, Alyeska #3
95-E-101
If there is any further information you need please call.
Sincerely,
Wayne enderson,PE
Attachments: Flow test, water quality analysis, location and map, site plan, surrounding properties map,
permit, well logs of subject and adjoining properties, test hole logs, sewer service as-builts.
NORTHERN TESTING LABORATORIES, INC.
600 UNIVERSITY PLAZA WEST. SUITE A
2505 FAIRBANKS STREET
FAIRBANKS, ALASKA 99709
ANCHORAGE. ALASKA 99503
907-479.3115
907277-8378
Christy Miller
3601 West 42nd Avenue
Anchorage, AK. 99517
Source: Tap Water
Sample ID#: A060289-1
/-6/'
(iu
Date Arrived:
Time Arrived:
Date Sampled:
Time Sampled:
Date Completed:
06/02/89
1608
06/02/89
0530
06/09/89
Parameter
Units
A060289-1
Sample
Standard
Detection
Limits
Volatile Aromatic Hydrocarbons - EPA Method 602
Benzene
Chlorobenzene
1,2 -Dichlorobenzene
1,3 -Dichlorobenzene
1,4 -Dichlorobenzene
Ethylbenzene
Toluene
Xylenes
Note: Sample run in
Reported By:
ug/1
ug/1
ug/1
ug/1
ug/1
ug/1
ug/1
ug/1
<DL
<DL
<DL
<DL
<DL
<DL
<DL
<DL
duplicate, ►ro other compounds
detected.
Date: 06/12/89
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.6
Francois Rodigari, Anchorage Operations Manager
NORTHERN TESTING LABORATORIES, INC.
600 UNIVERSITY PLAZA WEST, SUITE A
2505 FAIRBANKS STREET
FAIRBANKS, ALASKA 99709
ANCHORAGE. ALASKA 99503
907.470.31 15
907-277-8378
Quality Control Report
Client: Christy Miller
ID#: A060289-1
Listed below are quality control assurance reference samples with a known
concentration prior to analysis. The acceptable limits represent
a 95% confidence interval established by the Environmental Protection
Agency or by our laboratory through repetitive analyses of the
reference sample. The reference samples indicated below were analyzed
at the same time as your sample, ensuring the accuracy of your results.
Standard ID# Parameter Unit Result Acceptable Limit
NTL CCC5
Reported By:
Benzene ug/1 9.2 6.5 - 9.8
Toluene ug/1 6.7 6.2 - 9.3
Ethylbenzene ug/1 7.7 6.3 - 9.5
Chlorobenzene ug/1 8.5 7.2 - 10.9
p,m-Xylene ug/1 11.2 8.9 - 13.8
o -Xylene ug/1 5.9 5.4 - 8.1
1,3 -Dichlorobenzene ug/1 9.2 8.4 - 12.6
1,4 -Dichlorobenzene ug/1 7.9 7.8 - 11.7
1,2 -Dichlorobenzene ug/1 9.6 8.5 - 12.9
Date: 06/12/89
Francois Rodigari, Anchorage Operations Manager
nit
'Td Pp y AP__
L 2.01170
IA
L ?..0104,4
!3/4.kwitAta. cirr4 Am ;w.41: •
... .�.�w....4R�S �.Me•ar�a it.J iOf. • :jft 4� f s%^t';.r \. y'':hl"'"'•i6�:Et3t�T'7i4'�' •Lrt._e
1 ?1 U/ r E IA1CL2- 4 N i* 7EST HO L4 -
__".
G__". ocA-T/o Ai card S'v,8 7-c 7 A- nit!.
3 A-1)'1-0/ Iv la c:= pRo P -R' '/4
UJ L. L.
v� m�,0d
\ \
.\ l:
r // \ \. \
\
\
2/
\
\ \\
452
\ 13
SI.5
18
E131 AMML
12"x 23 1 F. e
REM •�
41.677
643
• K ro i Pr, .o'o
7
N
0
rte/
/ / c
i ��•
V'
3
310
30
30
SIM E L. 33676 3: 7. /
W. INV. 309.23
5. INV. 3094, 369.9
RIM EL 303:
W. INV. 296.06
E. INV. 1964 .29/.Ig
INSTALL 2OLF OF INSULATION
PER MUNICIPAL STANDARD DETAIL 235
'IM EL 280.0
J. INV. 271.50
•Mb/ *IV 1 C
+rw9.2 -Sri,2
29
28
280 15
27 10
11
'LL
t.ac, a+111,CU.
L
5T a .407
See, a f a c HCl
Sysj-Ecr 'AL.
Sh• et 2/+ of 29 SEWER SEKVICE SUING
LOT '.ELOCKi SADDLE
NO. /NO. STATION
22 5+/4 5
SWING TIE NO. 1
DESCRIPTION I
tt
C• 22
C;..�
6+ 22.5 1 C/L MH 617
i
7 22
6+ 84.7 i N to 19" Pine
1
8 ' 22
7 + 64 ' C/L MH 618
9 22
8+ 76 1 E to Power Pole
E
10
22
9 + 99 ; C/L MH 619
11
22
11 + 44 • NW Corner House
1
12
22
12 + 04NE Corner House,
L11,822
i
1
21
3 + 30.5 . SW Corner House,
L2,821
2
21
2 + 70 ' NW Corner House
12
21
11 + 58 • N to Power Pole
13
21
11 + 05 SW Corner House
1
14
21
10 + 54
SW Corner House
4
20
3 + 26.5
C/L MH 621
5
20
2 + 70
NW Corner House
4
22
4 + 61.5
NW Corner House
1-1
z
Tit
� J
J
N
Z
EXIST. q
SOUTH t
NORTH 1
1i 110
rep •.7.2Go
Oi-6' LP.
RIM EL 346.6 3/7./
W. INV. 309.23
e • u:. •f nn n.
350
0a 3d5
"naimommalliffer_ _10
F
-- Irrrqt
• ,rep 3'C.of I �
7 IA
MEM
UNIMEMMUM
rig
•
111W.Agoril
FEO
■Ii Asn ME
ism,
84-00
• 1
;9.7 .70
.,
NO.1sssa 6
9*00
!0 *00
UNWIN • SCHEBEN • KORYNTA
Consulting Engineers and Surveyors
103 E 26th Avenue
Anchorage , Alaska 99503
CFSl:'iN . 111:S
NO. 1
SWING T11 NO. ')
DESCRIPTIO' DISC .
7.7 N to 17" Pine 3fl.G
-s crjt DU LC-I-
-rae-T-+t4-5-1+rs-c-ew;a4
N
:
mil= L rt' Mani
Immo,
M
.aimmaimaMM11141111M111111 J
+r�w�r*i��MIIIIIIIM
MI= flr . MIIIIIMIE
Micl+�
1!lG�.CEMa iGl9 M
WWI 11.1.
{,
wpm
7.
tIliS 111=1111411111011111
IN1111111111111FAIr
i V4 Nom
// NENE
IMO MR1141111111111111101111•1111111111111•111/AMA NS MN
'[�►MO MIN= ►" its
Meglarimmuor
moo
ism
Fr
IC 1 MN
in ■�imra.rrm1mo ilk I��
• Minel
MN Ilia
MI IMO Mr MINI MI I_
IIIII NW AMP' 1111111111.111/A
111 1111111
11111MMI /AA 1111111111111111111
�r�■etieesi.
1
+w
AN(;I1ORA(JI;'WATER. Nr WASTI;IVA'I'I;Ir' L1'I'II,I'FY
Engiiicci'liig Division
.Alaskii 1)9O.3-I)H1g1
F,i>; ,Niiuihc r (907) Fi(i;'-O0"-'1.
I'ick Myst nuts,
,Uuyur
February 2, 1995
()Inlet! by the
Municipality of.1nc/z nrtyc
Ken Dreyer
Lantech, Inc.
440 W. Benson Blvd., Suite 103
Anchorage, Alaska 99503
SUBJECT: VACATION RFJJEST - Alyeska Subdivision Third Addition, Block 22, Lot 8
The Anchorage Water & Wastewater Utility has reviewed your request for vacation
of the 10' utility easements paralleling the northwest and northeast property
lines of referenced property.
The existing house, cantilever overhangs, eaves and well are shown on the
asbuilt drawing dated January 27, 1995, and are encroaching into the referenced
easements. The well which is located on the northern corner of the lot is
within 20' of the AWWU sanitary sewer mainline. Petitioner will need to resolve
the location of the well with Jim Cross at the Department of Health and Human
Services. Mr. Cross can be reached at 343-4708.
AWWU water mainlines are not available to the referenced lot. AWWU sanitary
sewer mainline is located within the Higher Terrace right-of-way, 10' from and
parallel to the northwest property line. AWWU requires a 30' easement or
right-of-way centered over mainlines. Under this requirement, for the
northwestern utility easement, AWWU must retain the northwest 5' while allowing
the vacation of southeast 5' of the subject easement. For the utility easement
located on the northeast 10' of the referenced lot, AWWU is not using this
easement and will not object to the proposed vacation of this easement.
This letter of non -objection is being issued to supplement your application to
the MOA Department of Economic Development and Planning per Title 21.15.130.d
of the Anchorage Municipal Code regarding vacation and replatting of the
subject property.
Should you have any questions, please call Hallie Morrison at 564-2721.
`42 -,Donald C. Keefer, P.E.
Planning Supervisor
Engineering Division
Anchorage Water & Wastewater Utility
cc. Jim Cross
Health and Human Services
P. 0. Box 196650
Anchorage, Alaska 99519-6650
GRID 4916
[wwhmm.wp.easement]72
1
1
W
n
R
ta it
. 1,
O9
0.1
«
X
r
p MWp
.Virg
N yl 0
2s
1 >t
y 0
u1
r11
STA. 4+4.3 1 STA M.N.616/77.9S.'j' )1�
1
a ,A
B to
I
MCI
3
ZZmIPS `<T
r
g
(Al
p.j W
N .�
V
• 4 'k
•
STA. 7+341
\ INSTALL M. H. 611/:'.' 5•.'/
1.14.32
OM
I
\ LI\
\ >'..
\ . 0'
STA. JO_ • 3L1
INSTALL N..H.619
(,Al/sul.HH. 7786.-.22
t W
t
A
W
N
N N
14
N
O
N
N
14
N
V
N N
N N
4.4
.0
U
W O
++
ON P
W
r
Eter. t112
00 0
O 0 P 4 2
'1 H P•1'1
00 ~ O O
0
n0 m4 0 m
IW- 0
WV,
N N Y
W".4 VI
ni.l((AINII
41411
irirr
ise
O 0 0 0
C
P4NW Y
t 00 V V.
'440 W O
W
O
•
II M
41 4
F
tb
31f1a3HDS
H
v
0
(z�
ISP \OW. OM
•
\
1 OM
N
+
Z
O
'O
0
N
N
N W N
V
O
N
I~+
'O
00
V
0'
NN
P
+ + + + + +
WO P
P it
V O'Oe NN
OAA t"DNt�
V V ,n
EMVZm
nro r0 „
ti N 3. 0 N 1
'O'1 0''d V
'0 0 w
0 0 0
0 01
0 tl
0In A
10
N
Y
W
0'
N
N
tol
t•
O 5-
W
N
W
N
U
OJ W
O O r
T. H. 17
N
O'
L.,
WN
WO,
NW
t.
W
M
O
N
0' V
6",
0 O
F
W2
41S
N 5'
0 11 0 0
0'A
P
A
5
7788
0
H
ti
V'
/
/
12 +11.3
IN At .0. 620
` ,(A/KJUl1
3lfla3HDS
H
I
D
v
NOIIJ(1I1SNOJ
V
/
GGGGGGG
W'0540NW W
Y'ON
VNrwOWN
OO VOO I, OP
O V 054 VNV
00E0 t� O .O V V1 00th
N
0
J
M
00.
017
7
N
N
1-
0
J
N
2
UD
N
W CO
W (0
Z 1
C5
Z
W
1 x
(/) a
W
Z
Z 0)
< N
J to
� 1
1 N
(1 o
CC Oto
ro_
40
(Po0)
om <
,0<
Ctz<
cn UJ
omw
UIQ
�W 0
O
U
O Z
0
II
M
1))
Of
0
January 27, 1995
ATTN: Utility Companies
RE: Easement vacation request
Lot 8, Block 22, Alyeska Subd. Third Addition
MOA grid #4916
No house number
Owner: Doyle Miller
Mr. Millers house, well, cantilever overhangs, eaves, and well were inadvertently
constructed into the 10' platted utility easements along the Northwest and Northeast
property lines as shown on the attached asbuilt. Since these easements appear to be
surplus to present and future needs, we are proposing to eliminate those easements
through the platting process. We would leave the 10' easements along the Southwest and
Southeast property lines.
We are requesting a written statement from each utility approving our proposed vacation.
If we receive approval for this vacation from all utility companies, we will then initiate a
preliminary plat.
If you have any questions or need further information please contact Ken or Tom Dreyer.
Thank you,
en Dreyer, RLS
0.
'WM.( M 11 616/77w'•..7
Au .K 617.77d7•a9
1
3\
O
to F;
ra
0,0
•
7
3
a
1
•
•
C
i
s
8
•
•
R
2
x
r
•
•
C
n
G
1
r.
f
3
2
a
F
w
'f
1
n
IP
•• • , L . • _
n n •
•
• • .
• 0 " n 3"
P A_
P
IP r
P
a
0
ta
0
4
.•o
1 N 17
17
Higher Terrace, Alyeska Subdivision Add'3
BLOCK 22
Lot. 4. Bk 22 65' to sewerline
75' to manhole DUPLEX
Lot 7, Bk. 22
Lot 8. Bk 22
(APPLICANT'S)
Lot 9, Bk. 22
Lot 10, Bk 22
Lot 11.61<22
Lot 12, 6k 22
Lot 13, Bk 22
BLOCK 21
Lot 11, 6k 21
Lot 12, Bk 21
Lot 13,Ek21
Lot 14.Bk21
Lot 15, 6k 21
Lot 16, Bk 21
Lot 17, Bk 21
Lot 18, Bk 21
19' to manhole
12' to sewerline
96' to manhole
21' to Sewer
Well 5/7/84
Single Fmly Residence
35' to Sewer Well 8/16/79
60' to manhole
Sewer stops 2 lots downhill
more than 75' to sewer
more than100' to manhole
WAIVER DEC 5/27/87
Well predates sewer/
No Well Log on File
Waiver Reouested 2/1/95
Undeveloped
No Well
Deemed Waived
Undeveloped
Well Drilled 8/22/84
127' to manhole 4 plxtlultifmly WAI VER D.E.C. 6/28/85
Well 8/14/79 Deemed Waived
53' to sewer well 8/13/79 Deemed Waived
manhole over 100'
41' to Sewer well 11/4/83 WAIVER
63' to manhole
40' to Sewer well 8/13/79 WAIVER
94' to manhole
47' to Sewerline well 8/10/79 WAIVER
over 100' to manhole
Residence No Well
10/2/84
10/28/87
10/25/85
48' to manhole Well 5/9/84
48' to sewerline WAI VER 1 1/25/87
0 to \(1 a - R
• �: ° / § i Ni /
• cc, R { \
4 \ r $ k
It; :#se;
/ }0
{
/-0
k{
Ri!
Lt
/07
.r°k3
�o•»
:5 Zti
g
/
.N
0
dsin £
£
0
/
0
/
0 0 CO
1- 0 ®
CO <
5
oCi
2
< / <
4
»
@,
/
i;
in to 0
tO
\ 7/
§ k
k\o.;
(Q� /
��Q b—
vi
Oa4
Dr • OC <
• §<1
3 0
){ )
)g¥ ?
N
•
•
•
P.01
HEFTY D ' IILLI G
Wall Weser .. Iti nat ;rally betted
3540 AKULA DRIVE
ANCHORAGE, ALASKA 99516
TELEPHONE:
(907) 345.0593
r
atm/ . 44 died/ A
&Mkc Lid Foto i D.
_pop P 4y_lei..LJ1. ! 40".eIJcJ.
a u c CLxcLc c(__/ w iG !/s 4 £J
°" _EJL_A ° Ate A4JI 'tonal dRDcZ
. 11
Ql��...._.QfSSGs/A0J et 414 •CAL
1 ---Lc gswy .
7� ato _ uta 4- ae,S uids
64 r. hiriT
•
row 4f'S Cio
0-9 .a yA &icw 11..4
sy$i-HS
• :HEFTY D ILLIr4G
W.0 Water - hl no
Y'cny betted
ul ,Q • :-
_1
•� J
sseo AKULA DRIVE
ANCHORAGE, ALASKA 9951
TELEPHONE:
(907) 345-0593
mitig
J... -AS. 950
Yi. it ali
--_ --- ASStS�,uit.
Ste— _aeti2.161az" &1s
HIT -
P.. 0 2
•
TTOP -TECHNICAL SE�R��,iVI.CES
CIVIL& ENVIRONMENTAL ENGNEERNG • ENERGY CONSERVATION & ANALYSIS
THEODORE F. MOORE, P.E.
PH: (907) 345-1355
November 6, 1995
Doyle and Christy Miller
1400 Shore Drive
Anchorage, AK 99515
Dear Mr. and Mrs. Miller:
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
Per your request I have reviewed the situation with respect to the well serving the residence
you own on Lot 8, Block 22, Alyeska S/D, located on Higher Terrace Road in Girdwood.
According to records on file at the Municipal Health Department a well permit was issued on
1/17/84. The driller's log indicates that the well was drilled on 5/7/84 and has a total depth of 106
feet, of which all but the uppermost 18 feet are drilled through bedrock. The well production is
reported to be 6 gpm coming in through fractures in the bedrock below a depth of 65 feet.
Because the lot is characterized by extreme slopes in the vicinity of 35%, the well was
drilled near the front of the lot, at a location only 21 feet away from a public sanitary sewer which
runs along Higher Terrace Road. This is much less than the 75 feet separation which was
specified on the permit for a private well serving a single family residence. The well is also only
96 feet from a sewer manhole, instead of the normally required 100 feet. I understand that your
recent request for a separation distance waiver has been denied by the Municipal Health Dep't.
On September 1, 1995 I collected water samples from the water supply system serving this
lot. The enclosed lab test reports show that the water quality was satisfactory, with 0 coliform or
other bacteria per 100 ml., and non-detectable nitrates. I also spoke with a well driller with regard
to providing additional source protection by sealing the well with grout, in order to justify issuance
of a separation distance waiver allowing the well to be formally approved in its present location.
Basically, this would involve installing a 4" diameter PVC liner inside the well with a shale packer
set ata depth of 65 feet between the outside of the liner and the inside of the bore hole. The driller
„would then use a Tremie tube to completely fill the annular space between the PVC liner and the
bedrock with a slurry_of expansive bentonite grout -This bentonite seal would extend up from the
shale packer -at 65 feet to just below the level of the pitless adapter. Once installed, this seal should
eliminate the possibility of contaminants from a leaky sewer line from making their way into the
bore hole through fissures in the bedrock. The well is partially artesian, indicating that the aquifer
is confined and not susceptible to contamination originating directly above. •
In my opinion, the proposed grouting remedy should be sufficient to justify issuance of a
r separation distance waiver allowing the well to be approved. In the event additional source
protection were felt to be justified, a IJV filter could also be installed inside the residence which
would guarantee that any pathogens which somehow made their way into the water system were
killed. Please feel free to give me a call if you have any questions on this letter.
Sincerely,
0J
Ted Moore, P.E.
Ex/ t377/1-1
G241b E
S'6-
Gt
-��
ote
all- 4
6 -44 -IDE