HomeMy WebLinkAboutANOTHER LT 7
Rick Mystrom,
Mayor
Municipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
September 8, 1997
Donald W & Carol R Kipfer
16448 Chasewood Lane
Anchorage, Alaska 99516 4829
Subject: Lot 7 Another Subdivision
Permit #SW960284, PID #020-093-36
The subject permit, issued September 6, 1996 by this office for a
single family well and/or on-site wastewater system, has
expired as of September 6, 1997.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. All inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
rely,~/C
s, ~.E.
nager
On-site Services
enc: Copy of Permit
cc: .James Sizemore & Associates
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW960284
DESIGN ENGINEER:JAMES SIZEMOORE & ASSOCIATES
OWNER NAME: Kipfer Donald and Carol
OWNER ADDRESS: PO Box 111334
ANCHORAGE, ALASKA 99511
DATE ISSUED: 9/06/96
EXPIRATION DATE: 9/06/97
PARCEL ID:02009336
LEGAL DESCRIPTION:
k!~O~HER LT 7
LOT SIZE: 50065 (SQ. FT.)
NUMBER OF BEDROOMS: 5 THIS PERMIT:
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) .
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS
RECEIVED
ISSUED BY: ~/~ f
PROBABLE IMPACTS TO ADJACENT PROPERTIES
A) WELLS
The proposed wastewater disposal system is designed in accordance with current
Municapality of Anchorage Wastewater Disposal Regulations. The proposed drainfield
will be constructed in accordance with these regulations. The separation distance from
wells on adjacent properties is greater than 100 ft. Therefore no unacceptable impacts are
expected on the wells located on adjacent properties.
B) WASTEWATER SYSTEMS
The new drainfield will be constructed with good separation distance from systems
on adjacent lots. Soils tests have shown the soil where the system is to be constructed is
acceptable for and an on-site disposal system, therefore there should be no unacceptable
impacts on adjacent wastewater disposal systems.
C) RESERVED SPACE/SURFACE AND SUBSURFACE
The large lot that this system will be constructed on has ample space, both surface
and subsurface reserved for a replacement system. The proposed drainfield should not
affect adjacent properties.
D) DRAINAGE
The location of the drainfield will not interfere with any drainage. The area
disturbed during construction of the field will be graded and sloped so as to not pond
water. Therefore this system shouldn't adversely affect adjacent properties.
LOT 8
%'~--- EXISTING
~ WELL... ~i! LOT7 ~/~
'
~.....--~ -" ~_ _/5_4_5__27_ _ __, ,, .--. ~ "'''
7- .... ,,
~ / '" --..,. ,. /
/X ~,~opo!%n / / 9 /
/.~wL) FR!I~_~I / /k,,,.~ E Xl S T/t/NG
--_.. ~ PROPOSE~ / ~.f WE/I_/IZ
'"--... : 1500 G~,-C- 'xx/ "'~,C'O' /b~//
~ ~ SEPTIC'
REPLACEMENT xx ~ "': x--- /----/""- //
FIELD ~ ~--''--.
'""'"--~ ~ 5 x72 DISPOSAL
TH #1 'TH #2 / TRENCH, SEE SHT 2
/
/
LOT 6
LOT 7, ANOTHER SUBDIVISION
PROPOSED SEPTIC SYSTEM
SITE PLAN
JAMES SIZEMORE &: ASSOCIATES
ANCHORAGE, ALASKA
TEL: (907),345-1572 FAX: (907),345-9629
DRWN BY: VND CHKD BY: JFS DATE: 8-15-96
SCALE: 1"=50' P.N. SHT: 1 OF 2
C.O.
WASTE LINE FROM HOUSE
PROPOSED 1500 GAL
SEPTIC TANK
DOUBLE C.O.
5'x72.5' LONG DRAIN
FIELD TRENCH
C.O.
72.50'
PLAN
MONITOR TUBE
1"=10'
4-" DIA. PERF. ~..-C.O.
PIPE ~ TUBE
'" ' - II' Lo
SEWER '"IU '. ,, '~
_.----i~.. ,, I ~ FILTER
ROCK- llil I1'11'''''''l FABRIC
51111
SECTION
1"-5'
I, I IIrl I I I ti I I I t I~lfli t I~'11 t I I t
I~ ~ James F. Slzemore
I
~ · ~ ·
I vA FCX ce- eee
I v~ ~m~.........~
LOT 7, ANOTHER SUBDIVISION
PROPOSED SEPTIC SYSTEM
PLAN AND SECTION
JAMES SIZEMORE & ASSOCIATES
ANCHORAGE, ALASKA
TEL: (907)54-5-1572 FAX: (907)545-9629
DRWN BY: VND lCHKD BY: JFS ~DATE: 8-15-96
SCALE: I"=IO'IP.N. ~ SHT: 2 OF 2
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
2
3
4
Depth to Water After ~ ~ / ET',/C~./-
Monitoring? ,/, ,~,r~', Dar .e:e:~f'
WAS GROU.D WATER
E.COUNTERED?
IF YES, AT WHAT
DEPTH?
Reading Date Gross Net Depth to Net
Time Time Water Drop
~'/'~ ~o~,
I'~ ~ ~-~ f ~ ~ .,~
PERCOLATION RATE ~ ~ (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN ' L ~ FT AND FT
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
COMMENTS
- //~" '-"' ~ ~ ' ~ ,~n 7 /0 / ~f~
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINEi,,C~IN EFFECT ON TH/tS DATE. DATE: [ ~/~.. ' (-
72-008 (Rev, 4/85)
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L' Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION: ~-O'~' 7 4/~(~¢'hd~-~'~ ~ U~°4/V'~'ship' Range, Section:-'
~oW-, ~ol'c
SLOPE
S TE PLAN
WASGROUNDWATER ~0
ENCOU.TERED?
S
L
IF YES, AT WHAT O
DEPTH? p
Depth to Water Alter~ M.,,%"~ (~/
Monitoring? J'~'~"-:,,. Oate:/~'c'/ P /~
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
2O
Reading Date Gross Net Depth to Net
Time Time Water Drop
PERCOLATION RATE ~. ~ (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN ~ z' 5 FT AND ~ FT
PERFORMED BY:- ¢-~;'=~¢¢;< ~~*~~ERTIFY. THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WlTHALLSTATEANDMUNIOIPALGUIDELI~;;FFEOTON%ISDATE. DATE'.
72-008 (Rev. 4/85)
6410
(907)
Switzerland Drive
345-1572
James Sizemore & Associates
Civil Engineers &
Surveyors
Anchorage, AK 99516
WASTEWATER DISPOSAL SYSTEM SPECIFICATION
LOT 7, ANOTHER SUBDIVISION
1.0 GENERAL:
1.1 The scope of the project consist of installation of a 1500 gallon septic Tank
and a five foot wide by 72.5 feet long wide absorption trench containing 3.5 feet of sewer
gravel.
1.2 Construction shall be as shown on the approved site plan and design drawings.
Deviations from the approved design drawings shall be coordinated and approved by the
engineer conducting the inspections.
1.3 All construction procedures and material used to construct the system shall
comply with Municipal and State regulations.
1.4 Unless specifically agreed otherwise, the homeowner shall be responsible for
finish grading areas atter the system is constructed and soil is compacted and mounded
over the wide trench disposal field and the Septic Tank.
2.0 SEPTIC TANK
2.1 The 1500 gallon septic tank shall have two compartments and shall comply
with Municipality of Anchorage Requirements.
2.2 The septic tank shall be set level and shall be bedded as necessary to prevent
settling or shifting of the tank.
2.3 All pipe connections to the septic tank shall be made with waterproof
mechanical couplings. A cleanout shall be installed upstream of the tank within 5 feet of
the house foundation. A double cleanout shall be installed downstream, within 5 feet of
the septic tank.
3.0 SOIL ABSORPTION DRAINFIELD:
3.1 The soil absorption drainfield shall be a 5' x 72.5' x 6' deep trench with a
total of 3.5 fi. of sewer rock, 3.0 ft. beneath the perforated drain pipe.
3.2 The bottom of the excavation shall be level. Any compacted or smeared
surfaces shall be raked to allow for proper infiltration of effluent. This includes both the
sides and bottom of the trench.
3.3 Sewer rock shall be 0.5 - 2,5" screened gravel with less than 3% passing the
#200 sieve.
3.4 Cleanout pipes and monitor tubes shall be 4" diameter and installed as shown
on the plans. The portion of the monitor tube extending through the sewer rock shall be
perforated.
4.0 ENGINEERING INSPECTIONS
4.1 A minimum of four engineering inspections will be required during
construction of the system. One after the septic tank is set prior to its backfill, one after
excavation of the absorption trench prior to placement of sewer rock, one at~er the
distribution piping, cleanouts and monitoring tube are in place. The final inspection shall
be after filter fabric is placed and the final grading are complete.
4.2 The contractor shall coordinate with the engineer at least 24 hours prior to
start of construction. If the contractor desires, a site visit with the engineer prior to start
of construction can be arranged.