HomeMy WebLinkAboutBEACON HILL ESTATES LT 2  MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME ~ IPHONE ~'~'",~'~ E~d~rlEW MAILING ADDRESS ~L~ ~0. OF B[D~OOMS ~ Manufacturer ~ Material No, ofcompartments~ Liq.~ac~n gallons IF HOME.DE: Inside length Width Liquid depth  Well Dwelling PERMIT NO. DISTANCE TO: ~ ~ ~ Manufacturer Material Liquid capacity in gallons ~ Well Foundation Nearest lot line PERMIT NO, ~ ~ ~ ~o. of lines ken,th of each line Total I~n lines Trench ~ ~ Distance betmeen lines ~ ~ ~ inches Q ~ Topoftiletofinishgrade ~/ Materialbeneathtile ¢1 inches Totaleffe~sorptionarea Length Width Depth PERMIT NO. ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ Well Building foundation Nearest lot line m DISTANCE TO: ~ Class Depth Driller Distance to lot line PERMIT NO. ~ Building foundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: SOIL TEST RATING REMARKS / ~ DATE LEGAL APPROVED 72-013 (Rev. 3/78) PERMIT NO. APPLICANT LORNE COUSTINEAU 2217 VANDERBILT RNC. BK. LOCATION BEACON HILL DR. LEGAL L 2 BEACON HILL EST. ~ LOT SIZE TYPE OF SOIL 8BSORBTION SYSTEM IS' TRENCH~-~o ~ix~'~ MR×IMUM NUMBER Of BEDROOMS = 4 2748855 30000 SQUARE FEET SOIL RATING THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: [:,EPTH= :.1.2 LENGTH= ~8 GRAVEL [)EPTH= :3 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD. THE DEPTH OF R TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). REm;iU I RED SEPT I C TAI'-.II< S I .'~E= 1250 GRLL. L-,Iq$ PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. T~O ~2) I t~$PECTIO[~_c; ARE REC!L) IREC~ BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL. SYSTEM IS 100 FEEl' FOR A PRIVATE WELU OR 150 TO 200 FEET FROM 8 PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC NELL WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT [dlTHiN 30 DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. PEF~:r-! I T E×P I RES C~ECEr, IBEI;;.' I CERTIFY THAT l: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. 3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS. V .:::. 2 4040 "B" STREET ANCHORAGE, ALASKA 99503 (907) 278-1551 June 26, 1979 W.O.# A18948 Grid: '2440 Mr. Robert W. Sullivan P.O. Box 10-512 Anchoraqe, AK 99511 Subject: Percolation Test, Lot 2 Beacon }{ill Estates Gentlemen: At your request, we have completed a percolation test on Lot 2, Beacon Hill Estates Subdivision in the hillside area of Anchorage. The boring location is shown on Figure 1. It was drilled using a continuous flight solid stern auger drill rig mounted on a Nodwe!l carrier. The rig is owned and is operated by Denali Drilling, Znc. Drilling was supervised the test hole logged and percolation test performed by Mr. O.M. Hatch, Alaska Testlab geologist. The log of the test hole is included as Table A of this report. In interpreting the log, it would be helpful to utilize the explanatory information contained on Sheets 13 of the report. When drilling was completed, a 3/4" slotted PVC pipe was inserted in the hole to aid in determining the free water level. For the percolation test, the test hole was filled with water and left overnight to saturate. On returning the next day, the hole was refille~ with water and the water level carefully monitored, for the Dext 60 minutes. At the end of the test, water ~epth was 4 feet below the ground surface. Page 2 W.O.'A18948 This procedure is not a standardized percolation test, however, we understand the Municipality of Anchorage, Dept. of Health and Environmental Protection prefers performed in this manner to evaluate the site.for proposed onsite sewerage system. Using the above test, the observed minimum percolation rate for a ten minute period was 6.7 minutes per inch. We suggest that the onsite wastewater system be designed for an absorp- tion area of 150 square feet per bedroom. This recommendation is based on criteria in the "Manual of Septic Tank Practice" U.S. Dept. of Health Education and Welfare, Public Health Service. We recommend the absorption trenches be inspected prior to installing the system as the above recommendations are based on the result of the sixinch test hole. The seepage trench will provide a much clearer picture of the subsurface con- ditions than the test hole. If the soil conditions turn out to be more favorable than predicted, it may be possible to economize the system by reducing the length of the trench. Conversely, if the 'soil appears tighter than anticipated, then it may be necessary to enlarge the system. The chief value of the drill hole is in establishing the feasibility of onsite systems, while examination of the trench is ex= pected to provide better specific information. The following items are attached and complete this report: Figure Table A Sheets Location Sketch Test Boring Log Standard Explanatory Information We trust this report meets your present needs. If we can be of further service, please feel free to contact us. Sincerely, Approved: Nichols, PE Laboratory Manage.r RMH/ee Date: 6-21-79 Logged by: O.M. Hatch Lot 2, Beacon Hill Estates TABLE A WO #D1 8948 Depth in Feet From To 0.0 I .1 1.0 2.0 2.0 3.5 3.5 7.0 7.0 16.0 Soil Description Brown Peat (Pt), damp, soft. F4, Brown Sandy. Silt (ML), damp, stiff, NP. Fl, Brown Silty Sandy Gravel (GM), medium density, damp, subrounded particles to 3", all sand sizes. F2, Brown Silt~ Gravelly. Sand (SM), damp, medium density, fine and medium grained, subrounded particles to 3". Fl, Brown Very Silty Sandy Gravel (GM), damp, all sand sizes, medium density, subrounded particles to 3". · Bottom of Test Hole: Frost Line: Free Water Level: 16.0 ft. None Observed None Observed Sample Depth 1 5.0 2 10.0 3 15.0 Remarks: 1. 3. 4. 5. 6. M% Type of Dry 'Sample Strength Group Unified G SM G GM G SM Type of Sample, G=Grab, SP = Standard Penetration, U = Undisturbed. Dry Strength, N=None, L=Low, M=Medium, H=High. Group refers to similar material, this study only. General Information, see Sheet 1. Frost and Textural Classification, see Sheet 2. Unified Classification, see Sheet 3. BOX 1[;~6~}l, ~TAR ].~,OUTli:../~ ANCI:IOltA~iI~, ALASKA ~. DRILLED AT THE RATE OF ~19.00 PER FOOT. LOCATION Of DRILLER B~ ~ o~ ~ ~~ ~o~. LOG: COST INCLUDES ALL LABOR AND MATERIAL FOR COMPLETION OF SAID DRILLING. WRITE CHECK PaYablE TO rampart DrilliNg works fOr ThE SUM OF . $~783o00 DAT~ THANK YOU VERY MUCH. ~ 20.t.k, 1979 SERVICE CHARGEOF I~% PER MONTH WILL BE ASSESSED ON BERNI~AUS Of RAMPART DRIL~ING WORKS ' PAST DUE ACCOUNTS. 1(3-101 STA £ ALASKA D~PARTMENT OF NATURAL RESOURCES mWS~ON OF LANOS 323 E~ST 4m AWNU[ ANCHORAGE, ALASKA 99501 SUBJECT I ~ filing fee -water z. ights APPLICANT NAME ADDRESS Robert W. and Avalon W. Sullivan · P.O. Box 10-512 ~ Anchorage, Alaska 99511 IILING FEES 1784 $1Q- O0 PURPOSE ACCOUNTING ADVICE NUMBER 59455 FUND SYMBOL AMOUNTlq'~'''[ O0.. 1 REMARKS: SCDO TEMP ~ 4407 R~MI1 EE F OTHER THAN APPLICANI BY DATI 08-24-79 CUSTOMER RECEIPT 3. Alaska Statutes 46.15.180 states in part that a person who constructs works for an appropriation, or uses a significant amot[ht of water without a permit or certificate of appropriation is guilty of a misdemeanor. 4. Filing for water rights aids the I)epartment of Natural P, esourccs in obtaining valuable data concerning water use and consumption in Alaska. This data is vital in assessing present uses of water, protecting the rights of prior appropriators, and providing for proper management of this important resource. Further information about water rights and copies of the application form may be obtained from the nearest office of the: Southcentral District 3327 Fairbanks Street Anchorage, Alaska 99503 279-7691 DIVISION OF LAND AND WATER MANAGEMENT Southeastern District Pouch "M" llth Floor State Office Building Juneau, Alaska 99811 465-2415 Northcentral District 4420 Airport Way Fairbanks, Alaska 99701 479-2243 Approved 4/78 ~;:~? ~.!,~~ ~!,i\~:[~:~ ,~,u,,~u . .=-~' MUNICIPALITY OF.ANCHORAGE..~ .~ ~ :?., .~ ~ ~:~,~:~?,*;:'~ .:? :~ :, DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTiON~ . ~, :/~ ~ ~ ...... ~ DIVISION OF ENViRONMENTAL HEALTH ~ ' ~ ~ ~ CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 ' , A'pplJcation Date i i 'ii:i~ ;,1.' GENERAL INFORMATION (a) (b) Legal Description (include lot, block, subdivision, sect~on,:~ownsh~p, Location (address or directions) Applicant Name'~! Applicant Address Telephone: Home Business (c) Applicant is (check one): Lending Institution []; Owner/builder []; Buyer []; Other [] (explain); (d) Lending lnstitution /~¢,.~'~ '"~.~,LJ-4¢_ Telephone Address (e) Real Estate Company and Agent (f) Address Telephone Mail the HAA to the following address: TYPE OF RESIDENCE Single-Family ~ Multi-Family [] Number of Bedrooms '~ Other WATER SUPPLY Individual Wetl~( Community[] Public[] ,: .... ;',k,;; ;~i:~:.,,i!'~:,. · ? . Note: If community well system, must have written co nfirmation from the State Department of Environmental Conservation 'i ' ".' ~ attesting to the legality and status. Onsite~ [] [] Holding Tank [] ' ' 7" Department of Environmental Conservation - ..: ~ !?, ~ Note: ~'f community well system, must have written confirmation from the state ~ ,~ ....... ,~ ~, ,,:., ~ ~,..~,~ ~-.:,~'.,,':,?.,',,r ~',',', ,,'. ',:~':'[~.'L.:,,~'.}:~':attesting to the legality and status. '.;. ' :.' '-;.' :: ~" ::~ ~ '* '~" ' ';;' ';" ~ * :;' ..... *'~';7 ';" ~'''.' ~,',~{~"'~'%'."'',""' ,.,/*;'~'h*'*.:" .,.~.,,~.. 72-025'" '~'{11/84)~' ..... Page 1 of 2 ENGINEERING FIRM PROVIDII' NSPECTIONS, TESTS, FILE SEARCH, D, AND INFORMATION 'i~ As certified by my seal affixed hereto and as of the validation date shown below, I verify that my ~nvesbgat~on of th~s Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this in~ctio~ ~ ,~....-- __~2 Name of Firm Telephone ~ ' ~ ~ / ~ Address ~ ~ ~/~ Date Engineer's Seal DHEP APPROVAL Approved for '?Ec~'¢' ~'~,/~ bed roe m s by '~¢'~ ~'~ ' ~"~'~'"'- ;¢ Approved Disapproved Conditional Date Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection '(DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (11/84) MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST- FEBRUARY 1984 MUNICI?ALI"P( OF ANCHORAGe. DEPT. OF HE,'"',LTH & ENVIRONMENTAL PROTECTION WELL DATA Well Classification Well Log Present (Y/N) Total Depth /~-'~ Static Water Level Casing Height Above Ground Electrical Wiring in Conduit (Y/N) Cased to If A, B, C, D.E.C. Approved (Y/N) Date Completed 7/~ Yield Depth of Grouting Pump Set At ~ f~'-. Sanitary Seal on Casing (Y/N) Depression Around Wellhead (Y/N) Separation Distances from Well: / c~¢~,u,¢~,~, / To Septic/Holding Tank on Lot 9¢ ; On Adjoining Lots To Nearest Edge of Absorption Field on Lot ; On Adjoining Lots To Nearest Public Sewer Line Cleanout/Manhole Water Sample Collected by Water Sample Test Results Comments ,~//',~ To Nearest Public Sewer ~//~- TO Nearest Sewer Service Line on Lot ~ / . /'~- ~/~~ ; Date ~/~-~/~/- B. SEPTIC/HOLDING TANK DATA Air-tight Caps (Y/N) Y Date Installed Size Standpipes (Y/N) Depression over Tank (Y/N) //~ Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) Separation Distances from Septic/Holding Tank: To Water-Supply Well ---- / To Property Line '~/~'" To Water Main/Service Line ~--~/-- Course W/"~ Comments No. of Compartments Foundation Cleanou, t (Y/N) Date Last Pumped ~'.,~.,~/~'~' ;for Temporary Holding Tank Permit (Y/N) To Building Foundation . ~/2 ' To Disposal Field /// To Stream, Pond, Lake, or Major Drainage Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field Square Feet of AbsOrption Area Depression over Field (Y/N) ./V/ Results of Last Adequacy Test Separation Distance~from Absorption Field: To Water-Supply Well TO Building Foundation Lot To Water Main/Se~ice Line ~0 To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Type of System Design Length of Field '~*/'// Depth of Field //~' Gravel Bed Thickness Standpipes Present (Y/N) Date of Last Adequacy Test To Property Line To Existing or Abandoned System on · On Adjoining Lots ,,~'(~ / TO Cutbank (if present) , ,/~? Comments D. LIFT STATION Date Installed ~ Size in Gallons "Pump On" Level at Dimensions Manhole/Access (Y/N) High Water Alarm Level at Tested for Electrical Codes (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted BedroOm Rating Against HAA Request ** I certify that I have checked, verified.or conformed to____al[ MOA and HAA guidelines in effect on the date of this inspection. Signed ~' ~ Date Company MOA No. Receipt NO. q Date of Payment Amount: $ ~.e. ~" ~ Engineer's Seal Page 2 of 2 72-026 (11/84) APPLI( NT FILLS OUT UPPER HA[ ONLY Prorerly ¢~.,-~,r ' Robert W. and Avalon W. Sullivan Phone Mailing Ad~l'ress SRA Box 2298, Anchorage, AK z,pcoae. 99507 q44-6059 Buyer Address Zip Code Lending Institution Phone Address Zip Code Realty Co. & Agent Coldwell Banker Jack White Co. / Elliot Lawson Phone Address ~)~]_ "C" St.. gUitP_ I_~Cl. Anchnrao~. AK Zip Code gq.~Cl3 2_77-1~.~3 Legal Description LOT 2, BEACON HILL ESTATES Street Locatio~ NHN R~cnn Hill II~ivP Type of Residence X~ Single Family Multiple Family No. of B~dro°ms [] Other Water Supply Xl~ Individual ATTACH WELL LOG, A well log is required for all wells drilled since June 1975. Community For wells drilled prior to that date, give well depth (attach log if available), [] Public Utility Sewer Disposal  Individual Year Individual Installed: Public Utility When Connected to Public Utility: [] Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. Time Time Time Time Date Date Date Date Inspector Inspector Inspector Inspector ~5~ SE P 2 9 R E C E iV E D (¢) JPPROVEO BEDROOMS *CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL* (S~ ~- ~ - 7 $ WelltoTank ~ ~ Septic T~k Size 72-023 (3182) 203 W. 15th AVE "C" SUITE 203 ANCHORAGE, ALASKA 99501 TELEPHONE: (907) 279-3916 RESIDENTIAL WELL INSPECTION LEGAL: LOCATION: OWNER: TYPE OF WELL: WELL LOG AVAILABLE: LOT 2, BEACON HILL 7441 BEACON HILL BILL WESTOVER SINGLE FAMILY YES INSTALLATION REQUIREMENTS MET: YES WELL YIELD FROM WELL LOG: 10 GPM. PUMP YIELD: DATE OF INSPECTION: 6 GPM. JULY 25, 1986 PUMPED AT A CONSTANT RATE OF 6 PER MINUTE WHILE THE DRAWDOWN WAS TEST FOR COLIFORMS: WATER WAS TESTED FOR COLIFORM BACTERIA ON JULY 26, 1986. TEST WAS NEGATIVE. TEST RESULT: THIS WELL MEETS THE REQUIREMENTS OF THE MUNICIPALITY OF ANCHORAGE. The Municipal requirement for well flow is 150 gallons of water per bedroom per 24 hours.This well surpasses this requirement. The assessment of the condition of this well applies only to the conditions as of this date. The flow rate of the well may change due to subsurface conditions that may not be observed from the surface, and changes in land use and other factors that may impact the conditions of the aquifer feeding the well. ~ - '.? ~ TEST PROCEDURE: WELL WAS GALLONS MONITORED WITH AN ACOUSTIC PROBE. THE WELL WAS PUMPED TILL THE DRAWDOWN STABILIZED. STATIC WATER LEVEL WAS FOUND AT 169 FEET. TWO HOURS OF PUMPING AT 6 GPM CAUSED THE WATER LEVEL TO DROP ONE FOOT. 203 W. 15th AVE 'C" SUITE 203 ANCHORAGE, ALASKA 99501 TELEPHONE: (907) 279-3916 SEPTIC SYSTEM ADEQUACY TEST LEGAL: LOT 2, BEACON HILL ESTATE LOCATION: 7441 BEACON HILL OWNER: BILL WESTOVER RESIDENCE: SINGLE FAMILY, FOUR BEDROOMS WELL: PRIVATE ON SITE SEPTIC SYSTEM: FROM MUNICIPAL RECORDS: TANK: GREER STEEL, TWO COMP. 1250 GAL. ABSORPTION SYSTEM: TRENCH ABSORPTION AREA: 656 SQ. FT. SOIL RATING: 150 INSTALLATION DATE: AUGUST 1979 DATE OF PUMPING: JULY 26, 1986. ANCHORAGE CESSPOOL PUMPING DATE OF TEST: JULY 25, 1986 TEST PROCEDURE: SYSTEM WAS INSPECTED AND MEASURED. TANK WAS FOUND WITH 6.5 FEET OF COVER. LIQUID DEPT WAS 48 INCHES. CLEANOUT TO TRENCH WAS NOT FOUND. TRENCH SUMP WAS 12.5 FEET DEEP WITH 61 INCHES OF LIQUID. WATER WAS ADDED TO THE SUMP AT A CONSTANT RATE OF 6 GALLONS PER MINUTE. THE WATER LEVELS IN SUMP AND TANK WERE MONITORED. A TOTAL OF 700 GALLONS WERE ADDED. THIS CAUSED THE WATER LEVEL IN THE SUMP TO RISE 22 INCHES. INFILTRATION WAS MONITORED FOR 2 HOURS. WATER LEVEL DROPPED 6.25 INCHES. TEST RESULT: THIS SYSTEM MEETS THE CODE REQUIREMENTS OF THE MUNICIPALITY OF ANCHORAGE. The operational life of all septic systems depends on the local soil conditions, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this septic system. We can therefore not give any estimate of how long the system will continue to meet the operational requi- remeQ.t'~-~o;f, the ~Municipality and State. ~%,,;~'.. JUN% 25. 1971 and .!ivalo~ ;4. ;Sc~iiiw~n ALaska 99507 SuiJj,.:~Ct~ L, ot 2, !.~ctac<.,u hill Esthetes An adequacy' test needs to be performed on thc existing ieachin~ area. This test will determine i~ t~e sy~te~a is adeq{uate actor-ding to National Standard~. ,'~ listing o~ private fzrms performing the test is enclosed. Th~s re/~ort needs to be ~.}ubmitte~.i to thZs office for ou~ ~-eview. discrepancies i~.~ve 0~Jen corrected. A[ t~re ~.re ~iny questions, i?tease c,ail tLli~ o££icc ~t 2~,I-,~'720. Jim Ro~Jert$ Associ~ite ~nviron~.cnt,.~-~.i Speciaii~'.:;t ALASKA RonmenTAL COFITROL $1 RUICE$, IF1C. I~nqineermq $ (~nuJronmen~ol Sludies OCTOBER 20 1983 MRS. SULLIVAN SRA BOX 2298 ANCHORAGE AK 99507 SELLER - MRS. SULLIVAN BUYER - SUBDIVISION - BEACON HILLS ESTATES BLOCK - 0 LOT - 2 ADEQUAC~ TEST FOR SEWER SYSTEM THE TYPE OF ABSORPTION SYSTEM IS A TRENCH WITH AN AREA OF 656 SQFT. THE SYSTEM IS CAPABLE OF ACCEPTING 600 GALLONS OF WATER PER DAY. THE SURGE CAPACITY OF THE SYSTEM IS 1000 GALLONS. BASED UPON THE TEST DATA THE SYSTEM IS ACCEPTABLE FOR A 4 BEDROOM HOME. THE SEPTIC TANK WAS PUMPED ON 9/8/83 . SEPTIC TANK ADEQUACY THE EXISTING SEPTIC TANK VOLUME OF 1250 IS ADEQUATE FOR THIS 4 BEDROOM HOUSE. 12oo tUcs~ 33d Au~nu~, 5u,e B · Anchoroq~. Alaska 99503 · (907) 276-1361 DEPARTMENT OF HEALTH & HUMAN August 12, 1986 Tobben Spurkland, P.E. 203 West 15 Avenue "C" Suite 203 Anchorage, Alaska 99501 Subject: Lot 2 Beacon Hills Subdivision Waiver Request, WR86-113 Dear Mr. Spurkland: Your request for a waiver of the 100 foot separation required between the well and septic tank on the subject property has been granted. This distance has been waived to 94 feet. This waiver is valid for the existing four bedroom single family dwelling only. Sincerely, Stephen S. Morris Civil Engineer On-site Services SSM/ljw CONSULTING ENGINEER 203 W. 15th AVE "C" SUITE 203 ANCHORAGE, ALASKA 99501 TELEPHONE: (907) 279-3916 MUNICIPALITY OF ANCHORAGE DIVISION OF ENVIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 6-6650 ANCHORAGE, ALASKA 99501 SUBJECT: JULY 31, 1986 MUN~IPALI/Y OF ANCHOP. N3E DEFT, OF HEALTH & ENVIRONMENTAL PROTECTION 3 1. 1986 RECEIVED REQUEST FOR WAIVER OF SEPARATION DISTANCES FOR PRIVATE WELL. LOT 2, BEACON HILL BILL WESTOVER Gentlemen; We are resubmitting a request for waivers from the separation distances stated in Title 18, Alaska Administrative Code Chapter 80.020 This submittal follows the format outlined in a Memorandum dated January 3, 1985 on the subject of "Separation Distance Waiver Guidelines for SCRO", prepared by Mr. Bruce Erickson, District Office Coordinator. State of Alaska, Department of Environmental Conservation. This Memorandum outlines a procedure to be used in the evaluation of waiver requests by assigning number values to geological features addressed in the waiver request. In this request I have followed this procedure and assigned values to the pertinent features as follows: 1. Vertical Distance Between Sewage System and Ground Water. The well log for this property shows water bearing gravel at a depth of 197 feet. The septic system is 12 feet deep. Vertical distance is 185 feet. Point value assigned 7.50 2. Soil Absorption. The material on the well log shows hardpan and clay from 22 feet to 197 feet. Point value assigned 5.00 3. Permability: The material described in the well logs has rate larger than 50 min/inch. a percolation Point value assigned 3.0 Tobben Spurkland P.E. Waiver Request Lot 2, Beacon Hill July 31, 1986 page 2 4. Water Table Gradient. This is a confined aquifer with 30 feet of pressure head. At maximum drawdown the gradient of the water table will be 0%. At less than maximum drawdown the gradient will be positive. Point value assigned 3.0 5. Horizontal Separation From well to septic tank 94 ft. From well to leach field 108 ft. Point values assigned For septic tank 2.5 TOTAL POINTS For septic tank 21.00 This total shows that the well is almost sure to be free from any form of contamination from house hold sewage originating st this septic system. The well is up hill from the septic contamination of the well is impossible. system. Overland Cast iron was used in the construction of the system. Septic tank has water tight couplings. Water sample taken during the operation of the system have not shown any contamination. I request that a waiver be issued for this property. Yours obben Spurkiand P.E. 2