Municipality of Anchorage ..;•` '•-,
Development Services Department
Building Safety Division .,...:
Onsite Water and Wastewater Program, 4700 S. Bragaw St.
P.O. Box 196650 Anchorage, AK 995196650 Paget of 3
www.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: Sal/ O 3 0 Z'y2 PID Number: 4 2.O -Y31- ZO
Name: To y RKbezrve 6�etb%
Wastewater System: [] New R Upgrade
Address: 93,11 Snow 6etrr Dom., M+Ch, P5761
I ABSORPTION FIELD
Phone: Number or Bedrooms:
3 YS'- Ya 95-
0 Deep Trench Q Shallow Trench [3 Bed t7 Mould C-) W 10m'b Other.
0 r?4-1" PrArt
LEGAL DESCRIPTION
BeAaaa 3,o
TatalDepdfromorrtivnalgrade:
1312
GPD(FP
Fl.
Diode Lot SubdMitiore
Depth to pipe bottom tram arigirW grade:
113
Gravel depth beneath pipe: SAN11
Ded'I I
H S- 6tar i-AettlRy
Ft.
t - "Ir F Ft.
Township: Flange: Section:
Fill added above original grade:
Gravel Lengft
2•S Ft.
6'O Ft.
Well: i5Xo F ❑New ❑ Upgrade
or"wwt
Nunberof finer.
/
Distance between lines:
—
.r Ft.
Ft
Classification (Private, A B. C):
Total Depth:
Cased to:
Total absorption arca r�
Pipe Material &�o Perf
FL
Ft
COO FP
_0 --?07Y NO,7 _ 00; F
Driller.
Date Drilled:
Stagc Water Levet
hummer. t
Date Installed:
� / D �
Ft
/A7
Yield:
Pump Set at
Casing Height Above Ground
TANK
GPM
FL
Ft
SEPARATION DISTANCES
[]Septic ❑ Holding ❑ S.T.E.P. /t K-Zo 19 Ot`r.
To
From
Septic
Tank
Absorption
Field
lift
Station
Holding
Tank
PubliclPrivat
Sewer Une
Maneladu'r"
© ren ro n k^
Capacity.
15-00 Gal.
Well
` /�
1. (j. -I
tH3
/DY
,725.
Material:
Fetter la.cf
Number of Compartments:
2
Surface Water
ter,
)fit
> je,'t
-
LIFT STATION
Size:
Manufacturer.
Lot Line
q40 t
IV s
e:0 r
1 Jam® Gal.
0 re17 Co
Foundation
'23,
7 2'
2 3 `
—
'Pump on' level at
l6 in.
'Pump air level at
25 In
High water alarm at:
I'Y . In.
Curtain Drain
Pump Make S Model
40 -Cl 112, hr
Electrical Inspections performed by. _
I lFa es . e l ec l-rYC
Remarks:
rner e4 hG Ire Is am ®r./
BENCH MARK
41
trouts✓ erwA"el F be4.^rrc/on c;l-e
Loatlon and Description
Co "am of -cirai earner v4,r
Gull 8#4t," PP((,,e /n1 %rltooe • & a1l6ca
Assumed Elevation:
/moo, O Ft
Akre rw4c4 back f6 or-� '061
-coil als:E hot Gerd, A,;,1V w o4 v4, leo( 1'r y' TSo
Engineer's Stamp
01: A Ohl .
(f er sctnoC a(er sew er rex eie /
r elerclioel 0n
e4 , f
dt,�� •• •• j#'%
0*IV
en tia� ccs 'rn Fel ham e
Inspections rto/-/Op TfC4 Dates: V1 7//7103�'�a
performed by: -f"e
e {�
2nd 7/6103...I�.....
eaeaa::N
�a
Development Services Department Approval
•a...... .::..�'.T:::1..
THEODORE F. AAOORE
Reviewed and approved by: Date: `� 2 034aa
j
,�•• CE - 3589 d =
•
a •,
I
PERMIT NO: SW030242
PID NO: 020-431-20
NEW 40 -FOOT LONG x 5 -FOOT WIDE
SOIL ABSORPTION DRAINFIELD w. 0.5
EFF. GVL AND 1.4' FILTER SAND
"BULL RUN" VALVE
T.H.
a..aaaa
ORIGINAL '
DRAINFIELD
SNOW BEAR DRIVE
I
PAGE 2OF3
NEW 1500 -GALLON
ADVANTEX Ax -20
MODE 1a TANK
T.H.
#2
-------- - - - - - -
1
i
WELL—
SWING TIES:
FROM: COR. "A" COR. "B" COR. "C"
TO:
�,ea�•�dy� TANK C.O. "0" 25.5' 49'
j°>Q, OF 4' TANK M.H. "E" 31' 59.5'
..
"�","• • • • <- P VALVE "F" 32' 62'
to FIELD y S.R.�� FIELD C.O. "G" 84' 77'
rt ; 497}1 FIELD M.T. "H" 88.5' 87'
..�". ". �....... •....N r.N. FIELD C.O. "1" 94' 97'
.,`THEODORE F. aapORE ; AV' LOT 5, BLOCK 4, BEAR VALLEY
w �
35s9p SEPTIC SYSTEM UPGRADE
A+ ••. ...".• .�. f
rv� 4f
4 AS -BUILT PLAN VIEW
"•^=sat Ey�,.�..a::f'='�'
PERMIT NO: SW030242 PAGE 3 OF 3
PID NO 020-431-20
RECIRC.
SPLITTER
VALVE (RSV)
rncrwan
INV. 95.5
; /- FINAL GRADE f M.T. C.O.-�
.._■i� '
• •
nu'
, PERF -7
"ADVANTEX" AX -20 MODE 1a
PRETREATMENT UNIT
INV. 85.7'
1.4' ISF FILTER SAND
ELEV. 85.2 t • •. • • ... .................
EX ...
.r
`�— BOTTOM C. ELEV. 83.8
INV. 85.T
RESIDUAL DISPOSAL
DRAINFIELD
BOTTOM T.H. #1
ELEV. 77.0
WATER 0 80.3'
Or At ',%
49TH
�w..{{{�N�{•�HH�bA4•H..Niew.�
F't a wTt'iODORE F. #ADORE
,<,.'. CE - 3589 4
JUL-21-2003 10:0'.#; FROM:A+ HOPE SERVICES, IN 907 -BW -67M TO: 3451355
P:1111
w
July 21, 2003
ED'S ELECTRIC INC. ""SAGE
P.O. Box 210767 1907) 2r2•4591
ANCHMAGE, AK 89521 Fax: (eon) 2n-4590
A !"come Services
1441" Avenue
Anchorage, AK 99516
Subject: Septic Lift Station. 9341 North Snow Bear, Anchorage, AK
Ed's Electric, Inc. installed alectrical on subject project, meeting all code
requirements of the National Electrical Code and all requirements of the
Municipality of Anchorage.
Thank you,
Dwayne R. t3runs -
Ed's Electric, Inc.
JUL•21-2@03 YON 08:S6AM IO:A+ HOME SERVICES, INC. PAGE:1
w MUNICIPALITY OF ANCHORAGE
Development Services Department tt
On -Site Water & Wastewater Program 1 C `O
4700 South Bragaw Street J 6 ii
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Jul 14, 2003
Expiration Date: Jul 13, 2004
Permit Number: SW030242
Legal Description^B:AR VALLEY f3LK = L`T
Design Engineer: 0019 Flattop Technical Services
Owner Name: Jo & Richard Gable
Owner Address: 9341 SNOWBEAR DR
ANCHORAGE. AK 99516-6913
Parcel ID: 020-431-20
Site Address:
Lot Size: 49756 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of.,
❑✓ Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy
All construction must be in accordance with:
1. The attached approved design.
❑ Private Well ❑ Water Storage
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3_ The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
System shall NOT be operated until a Maintenance Agreement is signed by owner.
Received By: .,,�... xc. lo� Date: % /
Issued By. ���r 4a' &±16-- Date: / "% 7 " 0 3
i
Municipality of Anchorage
• Development Services Department
Building Safety Division _•
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage:ak.us
(907)343-7904
ON-SITE SEWERNVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. - `� >) Z Q Permit Number SW 03 a 4 a
Property owner(s) cir rr� If' _ _ Day phone Y093—
Mailing address (1) 23Y/ N. ,.51)6 w beck'- D►�r•-e
Mailing address (2) AnCho ce f—e , A -k Zip Code 9ps/6;
Legal description (Lot, Block & Sub'd.) ke-,
Legal description (Section, Township & Range)
Lot Size_ Acres/Sq.Ft.
THIS APPLICATION IS FOR:
Number of Bedrooms Y
Sewer Only
❑
Well Only
❑
Sewer and Well
❑
Water Storage
❑
Sewer Upgrade
12
THIS PROPERTY CONTAINS:
Hot Tub
❑
Jacuzzi
❑
Swimming Pool
❑
Water Softening Unit
❑
Therapy Pool
❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes. A
(Signature of property owner or authorized agent)
Permit Fees: w0a 'Wo
Waiver Fees:
Date of Payment: 7 /3 /0 ? Date of Payment:
Receipt Number: _ Receipt Number:
(Rev. 12100) n .,
CIVIL k ENYMONMENTAL ENGINEERING • ENERGY CONSERVATION & ANALYSIS
THEODORE F. MOORE, P.E. 14S30 ECHO ST.
PH: (907) 34S-13SS ANCHORAGE, ALASKA 99516
July 2, 2003
M.O.A. DSD
P.O. Box 19-6650
Anchorage, AK 99519
Dear Sirs:
The purpose of this letter is to provide the required design narrative in support of our application for
a permit to upgrade the wastewater disposal facilities on Lot 5, Block 4, Bear Valley S/d, located at
9341 North Snowbear Drive. Soils logs, perc test results, a site plan, design drawings and specifications
are enclosed for your review.
Because of limited available space on the lot due to required separations from surface water, wells
and steep slopes, combined with a shallow water table and a slow percolation rate, we propose to install
an "Advantex" AX -20, Mode l a pretreatment unit that discharges effluent into a 5' wide soil absorption
drainfield. The proposed absorption system will be constructed in the vicinity of the west end of the
existing drainfield, and a `Bull Run" valve will allow subsequent diversion of effluent back into the
original drainfield as desired. As can be seen from the soil log for test hole #1, the native material
between 1 and 4 feet below ground level is a gravelly silt with a measured perc rate of 19 minutes per
inch between 3.5 and 4.0 feet below ground level. The material encountered in test hole #2 does perc a
little faster, however steeper slopes and proximity to surface water puddles makes this latter area less
desirable.
We feel the pert rate of 19 minutes per inch measured in T.H. #1 is representative of the soils that
will be encountered in the area of the residual drainfield, and the enclosed design is somewhat more
conservative than your guidelines allow for that percolation rate. It is my understanding that the
"Advantex" AX -20 Mode 1 a, has been granted DSD approval as a Category III Advanced wastewater
treatment system, which would allow a soil application rate of 4.0 gpd/sq. ft. in soils with a perc rate of
16 - 30 minutes per inch. In an effort to be somewhat conservative, we have actually based the design
on a soil application rate of 3.0 gpd/sq. ft. Thus, the required absorption area for this 4 -bedroom
residence is (4 x 150)/3 = 200 square feet, which is achieved by a 40 -foot long, 5 -foot wide drainfield
with an effective gravel depth of 0.5 feet. To further enhance the performance of the drainfield and
inhibit the formation of a clogging mat on the bottom, we plan to place 12" of M.O.A. filter sand under
the drainfield. We also propose to install a `Bull Run" diversion valve allowing the effluent from the
"Advantex" filter pod to be diverted back to the original drainfield after it has dried out and had a
chance to rejuvenate itself.
Because the proposed 4 -bedroom system represents an upgrade from the existing 3 -bedroom system
we have designated a site for a similarly sized residual disposal drainfield adjacent to the proposed one.
.f
The proposed project will have no significant impact on present or future water supply and
wastewater, disposal systems serving adjacent properties, nor will it have any significant impact on
reserved space -surface and subsurface, or on drainage.
I have requested the property owner to come into your office in order to execute the required
maintenance agreement. Please give me a call at 345-1355 if you have any questions on this submittal.
Sincerely,
Ted Moore, P.E.
UNSUBDIVIDED 25' CREEK
` EASEMENT
- \ \
CREEK—
------------------------------------------%
I116J1E.1
.i� 4e�.� t F jt A%. BLOCK 2 LOT 5, BLOCK 4, BEAR VALLEY SID
m, �..••••..• (VACANT)_ WELL AND SEPTIC SYSTEM
SITE PLAN
TH
/rrrirrrrrr•rrrrrrrrrr•:+:+� FLATTOP TECHNICAL SERVICES 1 INCH = 50 FEET
14530 ECHO STREET DRAWN BY TFM
rr.r•rrr �� ��rrrr���� ANCHORAGE, AK 99516
THEODORE I'. MOORE AF JUNE, 2003
'. CE - 3584 4b'
'•rrrrrr�•••••f � NOTE: THIS IS NOT A SURVEYED PLAT.
i[► _ ., V� ALL LOCATIONS SHOWN ARE APPROXIMATE.
--------
----------------------
LOT 5, BLOCK 4 PUDDLES
8'"' `»
C.O.
BEAR VALLEY S/D
- 28'
`
SITE FOR REPL.
DRAINFIELD
CONSTRUCT
DRAINFIELD
5' x 40'
DRAINFIELD
INSTALL
"ADVANTEX"
;
"REACTEX"`"
TRTMT. UNIT
as
T.H.
ADV. TRTMT.
VALVEI
#2 I
.i� 4e�.� t F jt A%. BLOCK 2 LOT 5, BLOCK 4, BEAR VALLEY SID
m, �..••••..• (VACANT)_ WELL AND SEPTIC SYSTEM
SITE PLAN
TH
/rrrirrrrrr•rrrrrrrrrr•:+:+� FLATTOP TECHNICAL SERVICES 1 INCH = 50 FEET
14530 ECHO STREET DRAWN BY TFM
rr.r•rrr �� ��rrrr���� ANCHORAGE, AK 99516
THEODORE I'. MOORE AF JUNE, 2003
'. CE - 3584 4b'
'•rrrrrr�•••••f � NOTE: THIS IS NOT A SURVEYED PLAT.
i[► _ ., V� ALL LOCATIONS SHOWN ARE APPROXIMATE.
--------
_ . #1
8'"' `»
C.O.
EXISTIN
- 28'
SEPTIC
EXISTING `'::::;
DRAINFIELD
TANK
HOUSE
;
"REACTEX"`"
as
ADV. TRTMT.
SYSTEM
WELL
,.
R 100'
R 100' WELL
SNOW BEAR DRIVE
a
a
a �
�
aaa
,
i
as '
a
a i
Yom—
�0/
- /
",Q
LOT 6
.i� 4e�.� t F jt A%. BLOCK 2 LOT 5, BLOCK 4, BEAR VALLEY SID
m, �..••••..• (VACANT)_ WELL AND SEPTIC SYSTEM
SITE PLAN
TH
/rrrirrrrrr•rrrrrrrrrr•:+:+� FLATTOP TECHNICAL SERVICES 1 INCH = 50 FEET
14530 ECHO STREET DRAWN BY TFM
rr.r•rrr �� ��rrrr���� ANCHORAGE, AK 99516
THEODORE I'. MOORE AF JUNE, 2003
'. CE - 3584 4b'
'•rrrrrr�•••••f � NOTE: THIS IS NOT A SURVEYED PLAT.
i[► _ ., V� ALL LOCATIONS SHOWN ARE APPROXIMATE.
ABANDON EXISTING TANK & CONSTRUCT 40 -FOOT LONG x 5 -FOOT WIDE
REPLACE WITH "ADVANTEX" AX -20 SOIL ABSORPTION DRAINFIELD w. 0.5 FEET —
Mode 1a TREATMENT UNIT _7 EFFECTIVE GRAVEL & 1.0 FOOT FILTER SAND
FROM HOUS TO ORIGINAL SOIL
ABS. DRAINFIELD
M.T. 40'
C.O.
�,•'��� ���`rpHNOR Y00 V'p00•NYI'•VpYNW blrM"YIrWbYWOOH
�\ IIYYp YN11tlMM9Y Yp YpppYN1YYODwpOY YJ1Y Yw YpDll
fY-w�.r W+wr W W.-• •Y W.rYI •YI-\F JMrw iw•rY
1 I i .rY'fY rY-YWiw N•v'Y-SYd•itiNV{1 WrIC•iYf W'►•-
\..� .\..�I 1/NYY•YY'•IYY.YV111MYYY..WYVN.YNOVNIIYNV
,'._• " ... �, •• �...-J Y•MYYfJ rpppppNYpppwY..ppYOp VwOwYYpYOp•Yp
YYYpYYV YW Ypp01\OYNYWRYY M•w1YWR1+Owp A14Y
C.O.
"BULL RUN" DIVERTER VALV "All
PLAN VIEW
SCALE: 1" =10'
4" D-3034
GRAVITY DISCHARGE LINE FROM
"ADVANTEX" FILTER POD
.j
"All
4" DIA. F-810 PERF. PIPE
C.O. /--- M.T. C.O.
3
�1
3'+ SOIL COVER
ORIGINAL
3'
,I.. GROUND
..
1c h+OA FILTER Y....
FILTER
ORIGINAL
49 FABRIC
GROUND
WASHED
GRAVEL
RESIDUAL DISPOSAL DRAINFIELD 4 DIA. F-810
PROFILE "A - A" PERF. PIPE
VERTICAL SCALE: 1" = 5' BOTTOM OF
EXCAVATION
N`L�
:•4✓THv`
••••/••_•.••••••••••••••%p16pp0
LOT 5, BLOCK 4, BEAR VALLEY S/D
��:..............
SEPTIC SYSTEM UPGRADE
:YiHE p Aeooae ; ATCE - 3584 a
:•• CE
PLAN AND CROSS-SECTION
�,�� t�
�`•••••••
FLATTOP TECHNICAL SERVICES SCALE: AS SHOWN
14530 ECHO STREET DRAWN BY: TFM
ANCHORAGE, AY,, 99516 JULY 2003
� �" 1 4
1 r
.Y'+4"�.V � aa."rurvq"YY�V1^!4a'SSy.
-
(� �_�
fl t # k..��:..
+ ..nw�ra....�r�.•••�•
Y
' ca����j
'w.,:w. ,«++raaew++ws�a
_—�
�
..
:fr��I�/�.:"'7rr
n`�. ws
w'�fi.vSm $4 $'vR
A
..�-
,
�� K � x ��=
x � * i x
� 1
��... �
=�
��
y
�
�x x � x �j
o � x
x x ■ xt
,.-.. . �
-_ � I
� 1
' �
�1�
`x
� X � 1f �
1* A�
ire
K �
�
"�
: r
�
�R � �
is
� i
�� -
M � ■ r
k� x' x ��
L
®_ s l
x � x � x
� � i
5 t
x i x t x
M� x � x ��
®
' i _
1
-f
n
x � �i i x
M� x i x '�
x w
�
1
i —
��
x�
M• is x ��
r l
a i � =
=�
,L� • r��u „ Jr
���� z ,_
�.
�si�
1'tl�
r
-
i��
���
:.
.-
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99518
TEST HOLE 0 1 SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION: Lot 5 Block 4 Bear Valley S/D
DATE PERFORMED: June 13. 2003
PERFORMED FOR: Je & Richard Gable
W E
(feet)
1'
2'
3.
4
5'
6'
7
tl'
9'
10'
11'
13
14
1
Pt.
MUGM Brown gravelly silt
Stratum thicker & cleaner io W end
ML Brown sift w. blue gray lens
Dense, cleaner & drier @ west end
SM Sand lens w. water seeps
ML Dense silt
B.H. f
"
.THEODORE F. AJOORE �' 1
e;t'' CE -3589
SITE PLAN
Depth to Groundwater Date
Se 0
" •.6
Date Reading
Clock
Tune
Net Time Percometer
(minutes) Reading
Net Drop
(inches)
13 " Pres ak
31
12" Resoak
31
Start
1 : 9
26314
25
Add r1:0915
27
02
1:39:15
30 /
1 /8
Add water
1:39:45
271/8
#3
2102A5
30 251121
5/8
L� PERCOLATION RATE 19 (minutestinch) PERC HOLE DIAMETER 8"
TEST RUN BETWEEN 3.5 FT AND 4.0 FT
COMMENTS:. This oerc test demonstrates that the upper portion of the ML stratum is able to accept water at an acceptable rate The
Overlying MUGM is cleaner and will perc at a faster rate. This nerc test was conducted near the west end of the test hole
PERFORMED BY FLATTOP TECHNICAL SERVICES. 1 15-.oe CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 7/ Z I 4:2-?
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
TEST HOLE # 2 SOILS LOG PERCOLATION TEST
LEGAL DESCRIPTION: Lot 5 Block 4 Bear Valley$/D
DATE PERFORMED: June 13, 2003
PERFORMED FOR: Jo & Richard Gable
nFPT14 cooezaooa SLOPE
6
7
8 ML Gray gravelly sift
Hard
g B.H.
10-
11-
12-
13-
14-
151
01112131415
18—
Is-
20—
PERFORMED
81920
10%
30%
150A
Depth to Groundwater I Date
OFar r,r •rr •••.•H••• HN►►�
At-
a C' - X39 .• ct
w3
It 6'
SITE PLAN
0%
E..
Date Reading
Clock
Time
Net Time Percometer
(minutes) Reading
Net Drop
(inches)
6/13 2" Pre-soak
271/2
12" Re -soak
271/2
start
231/8
/4
Add voter1:
723518
2
4
Add water
1:23
239/16
93
1738
is 19 518
316/16
PERCOLATION RATE 4 (minutes/inch) PERC HOLE DIAMETER e"
TEST RUN BETWEEN 3.25 FT AND 3.75 FT
COMMENTS: Small Quddles on ground surface 94' downslope from test hole.
PERFORMED BY FLATTOP TECHNICAL SERVICES. 1 ,J::� %?4s ►g CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 7 / Z / 15R�7
Flattop 7echnical'Seri*a
14530 Echo Stseet Andorage, AX 99516
('hone (907) 345-1355
Lot 5, Block 4, Bear Valley S/D
9341 North Snowbear Drive
Wastewater disposal system installation
Specifications
1.0 General:
1.1 The scope of the project consists of installing an "Advantex" AX -20, Mode 1 a treatment unit,
which discharges filtered effluent into a 40 -foot long by 5 -foot wide soil absorption drainfield that has
an effective gravel depth of 0.5 feet and is underlain by 12" of M.O.A. filter sand.
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
All construction procedures and material specifications shall conform to Municipal and State
requirements. All separation distances shall be in conformance with Municipal requirements, unless
specifically waived.
1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around
any buried utilities.
1.4 The contractor shall provide adequate cover material and rough grading over all system
components to ensure that proper drainage is achieved after settlement and that there are no residual
depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas.
1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading
after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the
construction.
2.0 "Advantex" AX -20 Mode la Treatment Unit:
2.1 The existing 1000 -gallon steel septic tank must be properly abandoned by thoroughly pumping,
removing the top and backfilling with soil.
2.2 The new 1500 -gallon, 2 compartment "Advantex" AX -20, Mode la treatment unit including
fiberglass septic tank and filter pod shall be Municipally approved and shall be set level on undisturbed
soil and backfilled in accordance with Municipal requirements as well as Orenco's and the supplier's
instructions.
2.3 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The
waste line from the residence to the septic tank shall have a minimum slope of 1/4"' per foot, and the
waste line between the filter pod and the soil absorption system shall have a minimum slope of 1/8" per
foot. A cleanout shall be installed 1 - 4 feet from the building foundation.
2.4 The contractor shall be responsible to obtain the necessary Municipal electric permit and
inspection, and shall provide a copy of the electrical inspector's report to the engineer overseeing the
construction of the wastewater disposal system.
2.3 The second compartment of the tank shall be equipped with a watertight, insulated manhole riser
and cover extending a minimum of 6" above final grade with positive surface drainage away from the
manhole. The contractor shall be responsible for determining the necessary length of the manhole riser,
and for properly positioning the Recirculating Splitter Valve (RSV) in the riser.
2.4 The control and alarm floats shall be set at the elevations specified by the supplier, and their
proper operations shall be verified by the contractor.
2.5 The treatment unit shall be set up with a "VeriComm" remote monitoring system as supplied by
the distributor, and the control panel for the unit shall be mounted on the side of the garage
3.0 Residual soil absorption system:
3.1 The soil absorption system shall be constructed by excavating a 5400t wide by 40 -foot long
drainfield to a depth of 3 feet below ground level, measured along the high side of the drainfield. The
long axis of the drainfield shall parallel a natural contour of the ground.
3.2 The bottom of the excavation shall be level. Any compacted or smeared surfaces shall be raked
to allow proper infiltration. A 12 inch thick layer of compacted M.O.A. approved filter sand (as
supplied by North Star Sand and Gravel — phone 745-1111) shall be placed in the bottom of the
excavation to promote desired infiltration and to reduce the tendency to form a biomat.
3.3 A total of 1.Ofeet of approved sewer gravel shall be placed on top of the filter sand with the
perforated distribution pipe laid level such that the pipe inverts are no less than 2.0 feet above the
bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing
the #200 sieve.
3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on
the design drawings. The portion of the monitor tube extending through the sewer gravel shall be
perforated.
3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. In lieu of
insulation, a minimum of 3 feet of soil cover is to be placed over the filter fabric.
3.6 The top surface of the cover material shall be raised a minimum of 6 inches higher than the
surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill
slopes shall be no steeper than 3:1.
3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have
the site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and
seed to promote rapid revegetation of all areas disturbed by the construction.
4.0 Inspections:
4.1 A minimum of 5 engineering inspections will be required during the course of the project: (1)
initial stakeout with the contractor to establish the location of the system and to discuss the plans,
specifications and construction procedures, (2) after the native material has been excavated to expose the
infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test
information, (3) after the filter material has been placed, (4) after the sewer gravel is in place and the
distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation
or filter fabric, and (5) after rough backfill and grading is complete. The "Advantex" treatment unit
requires one inspection after the tank is set level and the piping connected, but prior to backfill. This
inspection may be incorporated with any of the above inspections.
4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in
advance to ensure the availability of the engineer.
�,. MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
rr&
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME
PHONE
NEW
UPGRADE
MAILING ADDRESS
"t" �U
LEGAL DESCRIPTION
tti DIN,I�
LOCATION
NO.O BEDROOMS
11
Vr i
DISTANCE TO:
Well
f Q
Absorption area
' D
Dwelling
a�
PERMIT NO.
9-60170
Uy
aZQ
Manufacturer
Material
No. of compartments
LU <
k-
- L
N
Liq. capacity in gallons
r 0 0,®
I IF HOMEMADE:
Inside length
Width
Liquid depth
0 Y
DISTANCE TO:
Well
Dwelling
PERMIT NO.
J o Z
0ZFQ-
Manufacturer
Material
Liquid capacity in gallons
0
U,
DISTANCE TO:
Well
Foundation
�J
Nearest lot line
PERNUT NO.
5 D
J0 Z
No. of lines
Length of each line
Total len gt of lines
Trench width
Distance between lines
P Z w
b -
inches
_
HTop
to finish
Material beneath tile
Total
of tile grade
1
effective absorption area
0
;;5 5
/ ' inches
�a
Length
Width
Depth
PERMIT NO.
W
0
Q F-
Type of crib
Crib diameter
Crib depth
Total effective absorption area
as
w
W
Well
Building foundation
Nearest lot line
DISTANCE TO:
J
Class
'
Depth
D ' er
Distance tq lot
PERMIT 9N�.
-7
J
►(
K �
�_
l
C)' ICS
W
DISTANCE TO:
Building ;0),gdation
-
Sewer line
.__
Septic tank/�
Absorption area(s)
OTHER
PIPE MATERIALS
t45T-�4 D
SOIL TEST RATING
INSTALLER
� / ()�
K.� i W t'.
REMARKS
v
,e Or A
h 1
. rro
_
No 2225--E—`
JUKE 25, 1971
L
APPROVED DA E LEGAL
�� 4 —
- J�bw
72-013 (Rev. 3/78) �/
�l ~
( �
�1LJ 1"M 1: 1:1 1: 1W act a_z -1 ED F= ON PA ED hi ED FT fo U3 E�::
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L STREET, ANCHORAGE, AK 99501
264-4720
00_3 1 -I-EE E31EEh4EKFR in U41 Q L. L. 10" E7 1Fz 10 :1 -1
PERMIT NO: 850176
DATE ISSUED: 05/1`
APPLICANT: KINCAID & SON C/O T SPURKLAND
ADDRESS: 203 W 15TH'
ANCHORAGE, AK 99501
CONTACT PHONE: 279-3916
LEGAL DESCRIP: SUBDIVISION: BEAR VALLEY LOT: 5 BLOCK: 4
SECTION: 6 TOWNSHIP: 11N RANGE: 2W
LOT SIZE: 50800 (SQ.FT. OR ACRES)
MAX BEDROOMS: 3
Listed below are the options available to you in designing your septic
system. Choose the option that best fits your site.
J- lot ET 0A 171Vi~ 11 FT 1% AE 0,11
DEPTH TO PIPE BOTTOM (FT.)3.5 **
GRAVEL DEPTH (FT.) ' 1.0
TOTAL DEPTH (FT.) 11, 4.5
GRAVEL WIDTH (FT. 3.5 17 5.0
GRAVEL LENGTH (FT. 25 54 66.0
GRAVEL VOLUME ' 56 18.4
TANK SIZE (GALS) 1 0. 000. ** 1,000.0 **
SOIL RATING (SQ.FT. /BR) 40 J :3!;:3.;; 125
v ~
** DEPTH TO PIPE BOTTOM < QC FT. MAY REQUIRE A LIFT STATION
** TANK MUST HAVE AT LEAST =O COMPARTMENTS
_..... .... .....
______
I certify that: '
1. I am familiar with the requirements for on-site sewers and wells as set
forth by the Municipality of Anchorage (MMA) and the State of Alaska.
2^ I will install the system in accordance with all MOA codes and regulations,,
and in compliance with the design criteria of this-permit.
3. I will adhere to all MOA and State of Alaskarequirements for thc set back
distances from any existing well, wastewater disposal system or public
sewerage system on this or any adjacent or nearby lot.
4. I understand that this permit is valid for a maximum of 3 bedrooms and
�
� .
any enlargement will require an addition!! permit.
IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES,
THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS
WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3) THE
ELECTRICAL WORK MUST BE DONE BY LICENSED ELECTRICIAN.
** GRAVEL LENGTH > 75 FT QUIRES
** TANK MUST HAVE AT LEATWO COM
FT. EACH)
I certi[y that:
...... ....
���
�amiliar with the requirements
DEPARTMENT OF
HEALTH AND ENVIRONMENTAL PROTECTION
{orth b ' the Municipality o[
Anchorage (MOA)
825 L
STREET, ANCHORAGE, AK 99501
accordance with
all������c��-a � regulations,
and in compliance with the design
264-4720
'
3. Iill adhere to all MOA and
State o{ Alaska
requirements {or the set back
distances {rom any existing well,
PERMIT NO:
850176
adjacent or nearby
DATE ISSUED:
05/10/85
_
maximum o{ 3 bedrooms and
APPLICANT:
KINCAID & SON
C/O T SPURKLAND
^
IF A LIFT STATION IS INSTALLED IN
1::,
203 W 15TH
ANCHORAGE, AK
99501
CONTACT PHONE:
`
279-3916
REPORT; AND <3) THE
ELE:.CTRICAL WORK MUST BE DON� BY A
LEGAL DESCRIP:
SU�DIVISION:
BEAR VALL�Y LOT: 5
BLOCK: 4
DATE:
SECTION: 6
TOWNSHIP: 11N RANGE: 2W
---------------
LOT SIZE:
IM, (SQ.FT.
OR ACRES)
MAX BEDROOMS:
3
-
Listed belmw
are the options
available to you in designing your�
septic
system. Choose
the option that
best �its your site.
___
_..... ..... ..... _____...
..... ... ________..... ... ______
..... .....
If
DEPTH TO PIpE
BOTTQM
GRAVEL DEPTH
(FT.>
TOTAL DEPTH (FT.)
11.0 4.5
7.5
GRAVEL WIDTH
(FT.)
2.5 28.0
5.0
8RAVEL LENGTH
(FT.)
86 0 54.0
144.0 **
GRAVEL VOLUME
TANK SIZE (GALS)
1 .0 ** 00.O **
1,000.O **
SOIL RATINB (SQ.FT./BR)
/
^� 4O0 ��-~--� 330
445
** GRAVEL LENGTH > 75 FT QUIRES
** TANK MUST HAVE AT LEATWO COM
FT. EACH)
I certi[y that:
�amiliar with the requirements
�or on-site
ells as se�
{orth b ' the Municipality o[
Anchorage (MOA)
an o� Alaska.
2. I will install the system in
accordance with
all������c��-a � regulations,
and in compliance with the design
criteria o{
this permit.
3. Iill adhere to all MOA and
State o{ Alaska
requirements {or the set back
distances {rom any existing well,
wastewater
disposal system or public
sewerage system on this or any
adjacent or nearby
lot.
4. I understand that this permit
is valid {or a
maximum o{ 3 bedrooms and
any enlargement will require.an'
additional permit.
^
IF A LIFT STATION IS INSTALLED IN
AN AREA COVERED
BY MOA BUILDING CODES,
THEN (1) AN ELECTRICAL PERMIl' AND
INSPECTION MUST
BE OBTAINED; (2) AS-BUILTS
WILL NOT BE APPROVED WITHOUT AN ELECTRICAL
INSPECTION
REPORT; AND <3) THE
ELE:.CTRICAL WORK MUST BE DON� BY A
LICENSED ELECTRICIAN.
SIGNED
DATE:
-------------------------------------
APPLICANT: KINCAID & SON CVO T SPURKLAND
---------------
ISSUED BY
"
������������
BEAR
VALLEY
you in designing
DEPARTMENT
OF HEALTH AND
ENVIRONMENTAL
PROTECTION
TOWNSHIP:
your site.
11N
SECTION:
825
L STREET, ANCHORAGE,
AK
99501
OR
264-4720
DEPTH TO PIPE BOTTOM
(FT.)
_'E.:
c -n
.. ..... ....
�������,
PERMIT NO:
DATE ISSUED:
CONTACTPHONE:
LEGAL DESCRIP:
LOT SIZE:
MAX BEDROOMS:
850176
05/10/85
-
KINCAID & SON C/O T SPURKLAND
203 W 15TH
ANCHORAGE, AK 99501
279-3916
SUBDIVISION:
BEAR
VALLEY
you in designing
your septic
system. Choose the
6
TOWNSHIP:
your site.
11N
SECTION:
50000 (SQ.FT.
3
OR
ACRES)
DEPTH TO PIPE BOTTOM
~~ /
/ ^7
»~^u ( ~^ ~
LOT: 5 BLOCK: 4
RANGE: 2W
Li
ilable to
you in designing
your septic
system. Choose the
option that
best [its
..... .....
your site.
DEPTH TO PIPE BOTTOM
(FT.)
GRAVEL DEPTH (FT.)
TOTAL DEPTH (FT.)CD8.0
GRAVELWIDT[Al
GRAVEL
GRAVEL VOLUME(CU.YDS.>
10
TANK SIZE
SOIL RATING (SQ FT /BR)
/ ^/ 445
^^ 445
** GRAVEL LENGTH > 75 FT UIRES M / E RUNS (N[��E 5 FT. EACH)
** TANK MUST HAVE AT .... TWO COMPAR�4��NT�
____________... ^.______... ..... ..... .... ____..... ....
'....
_....
...
______
I certi[y that:
{amar with the requirements {or on-site sewer and wells `.amt. se�
If' orth by the Municipality o{ Anchorage (MOA) and the ate o� Alaska.
2. I will install the system in accordance with all MOA �odes and regulatiqns,
and in compliance with the design criteria o{ this permit.
3. I will adhere to all MOA and State o{ Alaska requirements {or the set back
distanc�s {rom any existing well; wastewater disposal system or public
sewerage system on this or any adjacent or nearby lot.
4. I understand that this permit is valid [or a maximum o� 3 bedrooms and
any enlargement will require an addi4iona1 permit.
-
IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOABUILDING CODES,
THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS�BUILTS
WILL NOT BE APPRO I AL INSPECTION REPORT; ..... (3) THE
ELECTRICAL WORK M D ELECTRICIAN.
SIGNED /� T.
..... �_��^..... ..... ~..... ..... _____..... _ ___..... .... ... ..... _..... ..... __..... .....
_
y°/�xn
APPLICANT: KINCAIDf� SON C/O T SPURKL�.'."
(n (.:,I BY DATE:
to,
IIl)zA �.V �.:. IDs: Tt t
1201 Ramona St. 99515 AN cn0RAc-�, ALasK x G
Z'0444-7724 r__,4 5 ) 7 / y
SIX INCH WATER WELL DRILLED ---------- OUT TO THE DEPTH OF 225 Teel,
DRILLED AT THE RATE OF $23.00 PER FOOT.
PROPERTY OWNER rilt- P.ich C 'Le 338-1394 aa � ���A
LOCATION OF WELL SITE 4. 5 B-lk.. 4 Sub: Beat Uatiec4 Sc�.(1T,[� L4 0)//xJ
DRILLR Be�vt.ie. C.tatte a Raait DA.f.GLln g lJv.tks. 5� i� � i'1 �2 G
7 /l� X �ejl 5m
WELL LOG: N✓ 4 _
0----17' s.i.l ic1 q&weL W,th 40% eta* binde. &let aia t"Aat.
17---49' T -tar- ghavcL wt th aeve.-mt z att bauLrr..a�t s. 15% ciaq.
49---74' R wet con. l oa3.e4a to 04 q lUWe- _ & hatdpan. Seue�ta.L bouide u.
74--225' Bed toc::. R aedLiraerit =,L toCA Rate✓%i.a.L. no wa.teA .412etd 4ho&b4 o¢ z4 n4-
.iccnce, =t -U 155 .to 162 A. About. 3/4 WIR. BA 195 .to 201 Av ptodactian..cLzp ued
.to C L04 e- .ta 1 1/2 CgPn, . R.� '.�: iue.Lq a.l.ow &eco ve4. at that depth. Ud.+'_Ltn ¢ �_cntZi u ed
.to 2Z A-' c- egad. ;wP-e PnA au o mtea4 o;L wa t.&t beating 4t,? , to 220 �.t.
1Jct.��t cyto n e„�avea c Mate a� 160 a 180 ,Lorl� pew hacuu. The uaGtPJt .ea
th,iid well. FuaAO-d cLarm. is 3 1/2 to 4 hound. The Vtel-d hoida good at- 2 112 .to 3 gPl"R.
Q:tai2 rr e'2=4 vew SLCute.cov�,.{� i4 bac L. up- to "th a 38 A a -G 4LVi�=c 1.6
ga. &z a._ uatvz. pee yt..in 4e sews aupp llt, Su. =v%4 -i &tr_ Awns ahautd lietn4 n.Ll e_d .ta
275-220 A. (3/4 HaA4e_) 4 3 A I 3 J 31
N01103103d 1VlN3WN0lIIAN3
T a tad. Cogs t o D:t i.GLinct vJ&j4&Vj"0=jjWvA-' 4 X 2-25 4: 55175.00
Ila 4et ,up on tiuuL4poAtat Lcn, codt.
COST INCLUDES ALL LABOR AND MATERIAL FOR COMPLETION OF SAID DRILLING.
WRITE CHECK PAYABLE TO RAMPART DRILLING WORKS FOR THE SUM OF S5175.0
THANK YOU VERY MUCH.— 7 Gc
BERME S OF RAMPART DRILLING WORKS
DATE "'aq- 27th,, 1985 '�
SOILS LOG
MUNICIPALITY OF ANCHORAGE
I' \ DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION
SII TEST
825 L. Street, Anchorage, Alaska 99501 264.4720
\\ SOILS LOG — PERCOLATION TEST
PERFORMED FOR: k I N C.At 1 > C�� DATE PERFORMED: �IC94S
LEGAL DESCRIPTION:
EP
SLOPE
(..+.. c.
SITE P
O RGA N I G B3 ,A v- r
1
2 T3 q -O /til C L
a G �t L"i �, S�N� V
0 P- AV C--- L jA)
4 0 l� W
5
I Tr
6-
7
V } O
9
10
WAS GROUND WATER j S C
11 ENCOUNTERED? _�V �J L
O
P
12 z. n ., s E
IF YES, AT WHAT
DEPTH?
13
14
15
16—
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
J
Cr A!��i�
_
o _
O . _
•4
J
18
.A .. ..
C2
1 1 O
'30
3%
�.2
a
Ll
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
J
_
o _
O . _
C,
C2
1 1 O
'30
3%
�.2
a
Ll
20
ill n t PERCOLATION RATE 611 (minutes/inch)
TEST RUN BETWEEN FT AND �' FT
COMMENTS Sy jl. [ A/ / 2.E- t4 C!4— W I b, I 13 E PtclkC /12 L/9 kE
q61,4 C -U' C)I -Flo Iq
�X10 �1.�
PERFORMED BY: CERTIFIED BY: DATE: 6
72-008 (6/79)
XSOILS LOG
MUNICIPALITY OF ANCHORAGE
j MUNICIPALITY OF AN©�LN�nEy�t�r,�)FNDArraWLLRRTppHEE&CCTTio��((
DEPARTMENT OF HEALTH AND EN�Xi�NIil1 ML PROTECT`IION PERCOLATION
TEST
�
825 L. Street, Anchorage, Alaska 9950 y6t42Qn�,)� SIA 1 ,. Ilyy
SOILS LOG - PERCOLATION TEST
RECEIVED•
S
PERFORMED FOR: � E +VI DATE PERFORMED: /
LEGAL DESCRIPTION: LOT 5 19 4 Y B ^Ak VALLEY, SRC- tbe T I / "'✓
R A
cl nOC SITE PI AN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
C�R6,ANIc-i SL ACK
s l i.Ty, SANDY, G 9-Arvtz"L
CMSM
t�-
✓.� oP,wrse...
WAS GROUND WATER
ENCOUNTERED? NID
COMMENTS 'eta.
PERFORMED BY:
72-008 (6/79)
IF YES, AT WHAT
DEPTH?
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
NA
7 �Xr
PERCOLATION RATE
� 6
CERTIFIED BY: i DATE:
H
---
Gross
Time
Net
Time
Depth to
Water
XJ} V.1�7Y,
4
i 1.1 t7 Y2 fa �4 A1► (� S 1 i—Ir
5
. , -m"j
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
Pouch 6850, Anchorage, Alaska 99502 276-2221
SOILS LOG — PERCOLATION TEST
SOILS LOG
❑ PERCOLATION
TEST
PERFORMED FOR: CG1Vti'"p V ~ 111�tl Z= 0DATE PERFORMED:
LEGAL DESCRIPTION: L B 1✓., '"7 135A?, \/Ik L»L.8 J S V JaD
SLOPE _ SITE PLAN
ON i C — -- II , --CS— ----
3
---
Gross
Time
Net
Time
Depth to
Water
L
4
i 1.1 t7 Y2 fa �4 A1► (� S 1 i—Ir
5
. , -m"j
I
6-
7 7
i
8-
t y
I
9
10
11 WAS GROUND WATER NI L
ENCOUNTERED?
O'
12 P�
IF YES, AT WHAT" E
13 DEPTH?
I
14
15
16
17
18
19
20
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
I
i
I
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
PERCOLATION RATE (minutes/inch)
I r1 TEST RUN BETWEEN FT AND FT ` /�
COMMENTS M L"r, 1G /boih watt 6-c-CJy.ocy— ai- IpI ! I">< � i++ICY 6^ed1rO!,i�
7 I`�i� 1� ®�1 ` �` I i C Y" 1+'J! % +r t Rc t' �' R�.*j't'rt�� ! _
PERFORMED BY: (� t) r �.—._ 1 ik.l�_ CERTIFIED BY: V .�3 {G� DATE: l'i /
72-008 (7/76) I y
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program : E,
4700 South Bragaw St
P.O. Box 196650 Anchorage, AK 99518-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 420 - Y3/- 20 HAA
Expiration Date: 10-;2,4 - 0
1. GENERAL INFORMATION
Complete legal description 1-vts Slag y, ��ir Ualla�i S /p
Location (site address or directions) 9 3 Yl Snow Seal' DrrLe
Current Property owner(s) Te ' OF fitG%Gtre/ 6a yle Day phone _3ys =Yo9s"
Mailing address 9 3Y1 Snow t eed' Dir�e10 An ef►�et 41c
Lending agency &"r itry -cvic% MO,'Asia4e Day phone
Mailing address _
Real Estate Agent Non FS CO Day phone
Mailing Address
Unless otherwise requested, HAA will be held by DSD for pickup. Pletwe call Clca rrr r 3 HS-�l09s
GuS L/� /,NFA r-le�y
2. NUMBER OF BEDROOMS: _
3. TYPE OF WATER SUPPLY:, TYPE OF WASTEWATER DISPOSAL:
Individual Well ® Individual On-site
Individual Water Storage ❑ Individual Holding tank ❑
Community Class Well ❑ Community On-site ❑
Public Water System ❑ Public Sewer ❑
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single -family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for go days from the date of issue for properties served by a private or Class C well and may be reissued with
new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.)
Certificates are valid for one year for properties served by Class A or 13 wells or a public water system. The
Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
d. STATEMENT OF INSPECTION BY ENGINEER',
As certified. by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-
site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality, of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
Name of Firm flce Tectinirc,! Ser��c� .
Address 1 yS30 Ectio Sf• /I�+chc�cpgP, � 4 99S
Engineer's Printed Name
r—.
Phone 3 VS--/X-Cr
Date fv/y Z2, 2au_7
'•�
".THEODORE F. MOORE NO J
5. DSD SIGNATURE , � •.. CE - 3589 i A
Approved for bedrooms.�� ��";"s `• ::
Disapproved.
X Conditional approval for 4 bedrooms, with the following stipulations:
At the time of title transfer the new property owner shall sign the attached
maintenance agreement which shall be returned to this pLUm before an uncon-
ditional approval is issued.
Additional Comments
Attachments:
HAA Checklist X
Septic System Advisory
Well Flow Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
By: _ Original Certificate Date: O 3
(Rev. 01102)
n
Municipality of Anchorage
Development Services Department
r Building Safety Division
On -Site Water & Wastewater Program S
4700 South Bragaw St
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907)343-7904
j
s HEALTH AUTHORITY APPROVAL CHECKLIST
i
Legal Description: -1,* f S, Bloc&- `f, i eetr 1/0/1'ey S/b Parcel ID: D 20 -y3/ -2p j
A. WELL DATA
Well type 'Pv 1� IfA, B, or Crovide PWSID #
P--N'-R', Well Log (YIN) Y i
Date completed -El 271S. Sanitary seal (Y/N) Y Wires properly protected (YM) Y
i
p Total depth 22- ft, Cased to Zft. Casing height (above ground) 2 Y in. j
E
FROM WELL LOG AT INSPECTION
Date of test -/ 27 / 85— 6- 3 /a 3
a Static water level 3 Fs ft. 3 ft.
Well production 2. S - 3 g.p.m• 2.3
9—
p.m-WATER SAMPLE RESULTS: I
Coliform 2 _colonies/100 mi, Nitrate 1,0 6mg•fl• Other bacteria a I
_ colonies/100 mi. I
Arsenic: mg./I. Date of sample: � /G3 Collected by: Ffermap T{moi See {
B. 'SEPTIC/HOLDING TANK DATA
s
Tank Type/Material _ lQdvcrrl 1-[x ,/r F lezu Date installed 714910?
Tank size 5"60 gal. Number of Compartments 2 Cieanouts (YIN) Y
r Foundation cleanout (Y/N) Y Depression over tank (YM) N High water alarm (Y/N)
E
Date of pumping ,y.,4. •( N-Icv) Pumper Al A.
C. ABSORPTION FIELD DATA
I s
I Date installed/7 ,s/03 Soil rating (g.p.d./frz orfta/bdrm) 3.0 System type S "-�tde e6rrin Xele(
f Length ti0 ft. Width -6 ft. Gravel below pipe 01 r
t 1, ti' rts� Sena(
Total depth AY. 3 ft. Eff. absorption area 20G f{' Monitoring tube ti" Depressionover field A/
,
Date of adequacy test N- A• ( Necy� Results (Pass/Fail) Pcb�r For 41 bedrooms
i
Fluid depth In absorption field before test _0 in. Water addedl� gal. New depths in.
Elapsed Time: _6� min. final fluid depth © In. Absorption rate >_ 6Gp g,p,d,
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date" Al-
3
Date installed 7 / 18/03 Size in gallons J_CQV Manhole/Access (Y/N) i
"Pump on" level at L6 in.
Datum lark of Bort ket
E. SEPARATION DISTANCES
"Pump off" level at ZS in. High water alarm level at 1A14 S in.
Cycles tested 1y A Meets alarm & circuit requirements? Y
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 101-1
Absorption field on lot r H 3'
Public sewer main N A
Sewer /septic service line 7 2S' �
On adjacent lots 7 106"
On adjacent lots > 1001
Public sewer manhole/cleanout N• k.
Holding tank N• A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 2 3' Property line `io Absorption field KOO
Water main N.A. Water service line > to' Surface water > 100 '
Wells on adjacent lots > !Go '
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 1 Z Building foundation 7 Z Water main N
Water Service line > 10' Surface water l 100 Driveway, parking/vehicle storage
Curtain drain 7 S-Z:P ` Wells on adjacent lots 14101+
F. COMMENTS
G. ENGINEER'S CERTIFICATION //}ter 4 ••� �,
1 certify that l have determined through field inspections and "'•'• sod ••••••••••••••_•»�
review of Municipal records that the above systems are inell
ill
,� ••••�••'••�•�•••••�
conformance with MOA HAA guidelines in effect on this date. �,l F. uooRE ;
tt . 358Q '
Engineer's Printed Name Th CCyCPG'1 F /-sc�a.,C,` �••••••••••••W
Tie r ,
.,
Date T �i -� ?a,, „•7
HAA Fee $ 3 7S �' Waiver Fee $
Date of Payment 7 Z 3� LDate of Payment
Receipt Number 3 T-1 `t Z C��_ Receipt Number
(Rev. 12/01)
7-22-03; 9:27AM; ;907 8615301 M 3/ 7'
w
SGS Ref0
1034174002
Client Name
Flattop Technical Srv.
Project NameH/
Various
Client Sample ID
L 5, B 4, Bear Valley SID
Idatrlx
Drinking Watts ,
Sample Remarks:
All DatesMmes are Alaska Standard Time
Printed Date/time 07/18/2003 16:41
Collected Daternwe 07/14/2003 14:00
Received Date/rine 07/14/2003 16:50
Technical Director �F Gcpj;cpC. Ede
Released �F--
Allowable
Parameter Qualifiers Results PQL Units Method Conte =]DLintits � E1 snit
Waters Department
Nitrate -N 1.06 0.100 mSIL EPA 300.0 B (<-10) 07/15/03 JS
microbiology Laboratory
Total Coliform
40B,NoColi ool/100ml, SM189222B A (<-I)
r,
io' arscrrr 6�+SEsyE7r��-_
2271
— - i7 `
-Ao' [.rr c z TN ES�•�T. � � `, �.os�.•»E,vr
1
i�
• itis
( to W s'1
4 U
NN
y Irl L,J
i 1 _J sy
AVERAGE SLOPE = 21% stvrrc va vrs I j i;
Cl• A
4�� Lo W
• i
/v/ it i � ... • .A. y1 �tr'1
`eve
00
0 0
B oo.vc. X ! • r b
• • •�•9iF 4- /•l GJ'.V(.S �•.��• Vi IfX/arNrj'STltup reR'
1. . tlOexllT JON e, 11r f • 3� W ti°
�, •., .• t:•' Co.vi. BL A• /1%tV AdAirpAl
t:„ rLfi!,�f+,r•. � 0 7EMR ' td�R.vv.po.vo
8.2 NJ
saf'3�'or t.v is'o,.y2 /oo�. Ptralvad0 `i�+isy
.S/VO W .� hZ4R �� A9R. fsoo'r e4ev. V q,? R
SURVEY TYPE`�---^--ISYMBOLS i
02 s.
®. AS - BUILT - NO CORNERS SET (Z) ASMZD ELEV. DRAINAGE
E3PLOT PLAN AS•BUILT :. LOT SURVEY -TOPOGRAP\ HY a"$"a" WOOD FENCE
s -+F-*-- CHAIN LINK FENCE,
❑ LOT SURVEY NOTE: Fences are shown in their approximate
❑ RECERTIFICATION AS -BUILT - NO CORNERS SET locations only.
It is the responsibility of the builder or owner, prior to LgGEND stub & tock -found 0 Set a
construction, to verify proposed building grade relative Iron rebor -fo=4 O set e
to finished grade and utility connections and to determine iron pipe -found set O
the existence of any easements, covenants or restrictions brass cap -found Set is
which do not appear on the recorded subdivision plat. alum. Cap found Set Q
Lot Survey Certificdtian Prepor d by
6 °F a�a°� • BENCIY li A n Pvc
I hereby certify that 1 have. e•
surveyed the property shown .���••""" •`••.,�tS`,f� Professional Lano Surve ots
&A dew.lbed hemons and Or Scales Orownb r
are improvements situated e'er. 1n$ r Y WAH
i es an within the property s .�+', � .�:" Date Surveyed t 5- Checked byr
linea and do not overlap or � 29.8E OGr4
encroach on adjacent property ! P' • r •i.� L:
oc�erenpopertyoverlthsnpor �l� 0.1K6ic� Dots Drowm 5-30-$5 Grid: W.O.
Oroencroach on the premises in t! r trete ,� 3234 85-06$
question ondIhot there art R�Fp�r99••re••.••'•� �,°' LegalOsearipiion,
no roadways, utility firms or RSI pA�E.S510NAt��
atherMOMeaasemsntson
Acid ex'itti•'� Lot 5, Block 4, Bear Valley
Subdivision
SIEa r° 2 os Wtrr Ft!c�.af�t^ Ctr/a,raf Cyt km
r Uy �� dCatwns of 2003 Acl van%+x
FrtedN Ar - bur M tnre. r7zrcre-7<
• MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIRONMENTAL HEALTH
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE
1. General Information Application Date
(a) Legal Description (include lot, block, subdivision, section, township, range)
Location (address or directions)
93q SNOWIlear. DatLvcW
aoQs
(b) Applicants blame PjCA4AV> C7AMIMLE Telephone - Home Business
Applicants Address Ld SNo vv 'f3 A.R.- 1�P t Y
(c) Applicant is (check one) Lending Institution; Owner/builder ;
Buyer � ; Other � (explain);
Act
M; kk, Askkpv
(d) Lending Institution µ®"E S4,vLNh5 a L,O&NS Telephone 2272-/qsj
Address NS® N
(e) Real Estate Co. & Agent N o w �
Address
Telephone
(f) Mail the HAA to the following address:
2. Type of Residence
Single -Family Multi -Family
Number of Bedrooms ,�
3. Water Supp
Other (describe)
Individual Well Community Public
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
4. Sewage Disposal
Onsite Public Community Holding Tank
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
5. Engineering Firm Providing Inspections, Tests, File Search, Data and Information
As certified by my seal affixed hereto and as of the validation date shown below, I
verify that my investigation of this Health Authority Approval shows that the on-site
water supply and/or wastewater disposal system is safe, functional and adequate for
the number of bedrooms and type of structure indicated herein. I further verify that,
f based on the information obtained from the Municipality of Anchorage files and from my
investigation and inspection, the on-site water supply and/or wastewater disposal
system is in compliance with all Municipal and State codes, ordinances, and regula-
tions in effect on the date of this inspection.
{r Name of
Address
Firm // 0 blo•C e-1 S; u r kLe,'� Telephone
P-0 --z> u�i J:
Date A!,
�« �� ."°" �0` Y' • ' �,e������
1 rr
f i Y
(ENGINEER SEAL)•:+�►•�•
�, • "o.
pia JW-. 2a• 1971
6. DHEP A roval �•
� S` pR"
Approved for �C � Verdrooms By Date"'
Approved liDisapproved Conditional _
'v
Terms of Conditional Approval _
CAUTION
THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE raPRESENT--
ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED
IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND
THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE-
MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A
CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS
OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK.
(DHEP SEAL)
RR4/ej/D18
[Page 2 of 21 T-199-84
A. WELL DATA
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
�JJG 3 0 94
RECEIVED
Legal Description: LOT 5 %V 4_A r.
V,JI•e.i Sec % . T//N. R0 L3 3 u!/
r
Well Classification "{ZES If A, B, or C, D.E.C. Approved(Y/N) N/A
Well Log Present (Y/N) YE --S Date Completed 51.2 71g-_6 YieldX. 5 1 Rj*7
Total Depth a95 Cased to 7V f Depth of Grouting NONE
Static Water Level 3 8 Pump Set At
Casing Height Above Ground a2 y f' Sanitary Seal on Casing (Y/N) .P
Electrical Wiring in Conduit (Y/N) y Depression Around Wellhead (Y )
Separation Distances from Well:
To Septic/Holding Tank on Lot ! O S v ; On Adjoining Lots > I v -,o
To Nearest Edge of Absorption Field on Lot 11b ; On Adjoining Lots >;o-�
To Nearest Public Sewer Line N ONE To Nearest Public Sewer
Cleanout/Manhole No 9 E To Nearest Sewer Service Line on Lot > to
Water Sample Collected By �'; S, / / //; Date gti9/mss
Water Sample Test -Results. Sa-4i -q l-aC'Z ry
Comments
B. SEPTIC/HOLDING TANK DATA
Date Installed C/,174_4 Size Iy-*- . No. of Ccmpartments
Standpipes (Y/N) y Air -tight Caps (Y/N) y Foundation Cleanout (Y/N) Y
Depression over Tank (Y/N) jet Date Last Pumped W 4Ajr' C~S�%---
Pumping/Maintenance Contract on File (Y/N) ; for ---
Holding Tank High -Water Alarm (Y/N) Temporary Holding Tank Permit (Y/N)
Separation Distances from Septic/Holding Tank:
To Water -Supply Well 103. To Building Foundation Z 2.
To Property Line 3 p f To Disposal Field 1 b
To Water Main/Service Line 40 To Stream, Pond, Lake, cr Major Drainage
Course N b N E
Comments
Receipt # '55= 0
Date Paid:-3�-�
Amount: 45
(Page 1of2]
2-15-84
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata Type of System Design Y& %ti4NeA
Date Installe 4/,q�g $ Length of Field
Width of Field S r T: S. Depth of Field f� j
3-15 Gravel Bed Thickness
Square Feet o Absorption Area�j--' Standpipes Present (Y/N) ON
Depression over Field (Y/N) N Date of Last Adequacy Test N%,er X•r/ CONS/; -
Results of Last Adequacy 'lest -
Separation Di�tance from Absorption Field:
To Water -Supply X11 Ilto To Property Line 3,0
To Building Foundation 3 j To Existing or Abandoned System on
Lot ; On Adjoining Lots 36 4
To Water Main Service Line Y,� If To Cutbank(if present) No N L
To Stream/Pond/Lake/or Major Drainage Course N 0 Nl=
To Driveway, Parking Area, or Vehicle Storage Area 3 O -f'
Comments
D. LIFT STATION I N o N
Date Installe Dimensions
Size in Gallons Manhole/Access (Y/N)
"Pump On" Le 1 at "Pump Off" Level at
High Water Alarm Level at Vent (Y/N)
Tested for Pumping Cycles during Adequacy Test. Meets MDA
Electrical Co s(Y/N)
Comments
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or, conformed to all MOA HAA Guidelines in effect
on the date of th s inspection,,.,
Signed _19,
Company
KBl /d5/s
(Page 2 of 21
Date
f C MOA No. 94r,% %O {
*II EES .
..
are ......... 0...
.Q o. 2225-E ;
�► JUNE 25. 1971iio
AW
2-15-84