HomeMy WebLinkAboutBENBECCA BLK 1 LT 2A
' Municipality of Anchorage Page of_
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: .?A) ~O/~-~.. PID Number: D.~/- ~'Z- ~a~/''
Name: ~O/1,,t,'J'~ ~ Wastewater System: ~New ~ Upgrade
Address:
~q3 ~z ~s~ ~. ABSORPTION FIELD
Phone: [ NO. of Bedrooms: ~ ~ Deep Trench ~Shallow Trench ~ Bed D Mound D Other
Total Depth from original grade:
LEGAL DESCRIPTION SoilRating: ~ GPD/Sq. Ft. ~,~+
Subdiv~ion: Depth to pi~ bo~om from original grade: Gravel depth beneath pipe
Lot: ~ Block: / ~~ ~,?~ ~ ~ ~,f~+ Ft. ~' /~ ' '- - ~' ~ Ft.:
Township: ~ Range: ~ Section: Fill added above original grade: Gravel length:
2,5~ ' Z,~ ~t. ~'~ ~ ~.~ Ft.
Gravel width: Number of lines: ] Distan~ ~tween lines:
WELL: ~New D Upgrade E~, ~ ~ Ft. ~ I /~ Ft.
Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: ~ Pipe material:
Driller:~ ~ ~/ ~//~ ~ ~'~'~Date Drilled: Static/~Water~Level:Ft.Installer: ~ Date installed: ~-~
Pump Set at: I ~sing Height A~ve Ground: TAN K
Yield: ~ GPM ~~ Ft. ~ Ft.
SEPARATION DISTANCES ~Septic ~ Ho,ding ~ S.T.E.P.
From Tank Field Station Tank ~we, Lin~ ~
Well- /~ /~[~ ~ ~ ~/~ Material: 5~/ Num~rofCompa,ments:~
Sudace l~
w,ter /~ /p~ -- -- /0~/~ LIFT STATION
Line /~ /~ -- /~f ~ Sizein gallons: Manufacturer:
Foundation /~ fG /~ /~ .... "Pump °n" level at: ~evel at: I High water alarm at:
Cu~ai~Drai~ /~0 I~ /~0 ~ -- ~ -- ~ ~ Electrical Insp~tions pedormed by:
Remarks: ~ ~~ ~~ ~ BENCH MARK
Location and Description~ ~/~ ~ ~ ~
*m ~,~ation: /~ ~,
~,,~'~: ENGINEER'S SEAL
Inspections pedormed by: ~ ~/%~~Dates:lstO~-D3~~~
e,a.-en, o, u.an S s .a .ova,
Reviewed and approved by: (~~ ~' ~ ~ Date ~-~'q~
72-013 (Rev. 9/91} MOA 25
AS-BUILT SYSTFM DETAILS/SITE PLAN Per-ni~ swssoiaa
BENBECCA S/D, LOT aa, BLOCK 1 PID~O5i-O5a-64
LIT1
RESERVE SYS~N ~ ~ X///? //I ~~ .....
TH ~98-a I ~ ~ /~~ v ,, Y/AR ~
~ ~ ~ ///I ' ///~ la50 S,T,- ~
~~F PRIMARY SYSFEM
- C = 23,3' 5 / /..~6~$% / IDNITBR TU~E MONITOR TU~ nCLEANOUT
A-E=51,B' B-D=35.0' A-D=29,8' ~ ~~ '"- =.-- :.~~ . -- ~'~ ~'"'~ ~~ ~ ~ w~,~o~ ,,
A-F:~l,o'~ ~ ~ T~,C,,
B-F=80,7'
58,4'
CLK~NOUt ~ FINAL GRADE
~-~=80,8~
9-H=95,0' ~
~ TRENCH a
~ OF ~ ~ PREPARED FOR~
~ ~49 TH~ 7, ~ KING ~EaL ESTATE
243aa REESE RD,
*
ENGINEERING
~ ~. , /_ /~-~ .~ SEWARD KMD
' ~ ?~0 ~/~qq ~~ s,*x,.~: SEWARO CHECKED: KMD 80441 PTA.MIGAN BLVD.
· ~s~':: a. aOSNSO ~: 2/9/99 EAGLE ~IVE~, AK 99577-8?36
~?~°~ssm~x ~ l[ " ...'::: :. :.:. '.:::::.::]l
~ ~~ ~wo. r~E: o~m: NWl 5 61
,WEU. DEPT~T:, · , ' ' ' OAT~..OF<¢OMPLETION'
...,......... .,, , ,,; '~',i .... ... ,,
. ...... ..,...'., ..,.:. ,,,..,.......- -,,,,:',~. /~.'./.. ~ ;~.~r,'~ .. ". '.~ '.
: ']' ' ..... ,.' :.". '. ~..':"~'~.' v.;;.'...'... ',,:: ~ .... ~"" ; .~ . ,. ..... . .. ..... . ,, ,
,, .;.,:, ' ,'., .....~?: ..~ .,. .,........ .... .it.
:4. '" ~': E'VE£OPM..ENT METHO0:' :
.'.,.;
Permit Number: SW980122
Design Engineer: 0070 KND ENGINEERING
Owner Name: Bonnie King
Owner Address: 24322 Reese Rd.
Chugiak, AK 99567-
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM/WATER SUPPLY PERMIT ~L~:,~
Initial
Date Issued: May 19, 1998
Expirati~pate: May 19, 1999
Parcel ID: 051-052-64
Legal Description: BENBECCA BLK 1 LT 2A
Site Address:
Lot Size: 40128 SQ. FT.
Total Bedrooms: 4
Permit Bedrooms: 4
This permit is for the construction of:
[~ Disposal Field [] SepticTank
[~ Privy [~ Private Well
Holding Tank
Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
~N~ ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907)696-6111/FAX (907)696-8111
May 1,1998
Municipality of Anchorage
Dept. of Health & Human Services
On-Site Services Section
P. O. Box 196650
Anchorage, Alaska 99519-6650
Subject: New sewer/well permit - Benbecca S/D, Lot 2A, Block 1
Gentlemen:
On April 24, 1998, we excavated two testholes for the subject property. The results of
these tests and water monitoring are attached.
We propose to install a 5' wide shallow trench. There was no water observed after
monitoring for 9 days, however, due to the area we have designed the system in the
upper top four feet of the GM layer. Additional fill will be placed over the system to
provide a minimum of 3' of cover when complete. This lot slopes from east to west
at approximately 2-7% which is away from the proposed house and any surrounding
wells. The system will be placed at the base of a small fill slope in the insitu
material.
We propose to drill the well southeast of the house and septic area. There are no
public or private wells within 100' of our proposed system location. There is neither
surface water within 100' nor any known curtain drains within 50'. We do not
expect that there will be any adverse effect on adjacent lots by the development of
this system.
If you have any questions, please contact me at 696-6111/FAX 696-8111.
Respectfully submitted,
~I~[~) Engineering
attachments:
On-Site Well and Sewer Application
Wastewater Absorption System Details/Site Plan
Soils Log/Percolation Test
WELL
WASTEWATER DISPOSAL SYSTEM DFTAILS/SITE
BENBECCA S/D, LOT aA, BLOCK 1
I
(95-183)
lA
40,030 SF
T~
ROPOSE~ RESERVE
TH #9B-~
1850 GAL, S,Tr
SF
SYSTEN
r,,,i, u
r~;
VACANT
VACANT
NO PUBLIC ~/ELLS ;VITHIN 200' OF
PROPOSED SYSTEM,
NB PRIVATE ~/ELLS VITHIN EO0' I]F
PROPOSEI] SYSTEM EXCEPT AS NOTEB,
NO SEPTIC SYSTEMS ~/ITHIN EO0' OF
PRQPOSED ~/ELL EXCEPT AS NI]TEB.
PLAN
30 89
i SEPTIC
10' U'~IL
.__ X,:.:::,..17.:..,.~i .............................
31 38
~ SEPTIC
RACE DR,
::,, SEPT!C
VACANT
4A
DESIGN DETAILS
4 BDRM X 150 GPO = 600 GPO
600 GPD/O,6 GPO PER SQ, FT, = 1000 SQ, FT
(1000/(5')) X 0,58(RF) (3,0' GRAVEL) = 116 FT, TRENCH
USE 8 TRENCHES 58'(L) X 5'(W) X 3'(D)
Total depth o? system is 4,0' ?rOM original grade,
Total depth o? gravel below distribution pipe is 3,0' ,
NBTES~
1, USE 1850 GALLON SEPTIC TANK, INSULATE TANK IF <4' COVER,
8, INSULATE TRENCHES ~/ITH 8' HD BURIAL FOAN,,
3, CONTRACTOR WILL ENSURE NAXIHUH 8% SLOPE INTO SEPTIC TANK,
4, ADDITIONAL FILL ~/ILL :BE ADDED OVER SYSTEM TO ACHIEVE
MIN, 3' COVER IF REQUIRED,
PREPARED FOR~
BONNIE KING
KING REAL ESTATE
84388 REESE RD,
CHUGIAK, AK 99567
FIELD BOOKS COMPUTED:
BOUNDARY: SE~WAR[) DRAWN: KMD
s'rAKING: SE:WARD CHECKE~): KMD
...~','::L........~F,.w, .AF!P_ ............ '.~.F':".L ............ .~Z]..Z~. .................
Dwc. r~Le e~,~o: NWl 561
^CAD F~LE: 98051.DWG m, ,o.: 980,.51
Sco, Le~ 1'= 100'
SHEET 1/P
B, NGINB, EI~ING
E0441 PTAI~MIGAN BLVD.
" ''" ~' 99577-8736
EAGLE I~IVLR, AK
/9071696-6111/FAX /9071696-8111
WASTEWATER DISPBSAL
3ENBECCA S/D, LOT
SYSTEM
Pa, BLOCK
DETAILS
1
898-
1250 GAL, S,
S¸p
TTTER
SFI}
FC
RnPF1SED
PR
SYSTEM
0~145,16
SF
PREPARED FOR:
BONNIE KING
KING REAL ESTATE
84388 REESE RD,
CHUGIAK, AK 99567
FIELD BOOKS COMPUTED:
BOUNDARY: SEWARO DRAWN: KMD
.... ;:i';;~';;'~:'""-'~¥~-~- ...... ;',;~;¥<-E~ .......................
.... '~!.'::!L._.S.!L.WARjA .......... ? ~ ~j ........ ~_Z...! I ~_8... ..................
DW<;. rll.£: GRID; NWl 561
AC^P r'lL~:: 98051 .DWO ,~o. No.: 98051
ScaLe, 1"= 20'
SHEET 2/2
ENGINEERING
204.4.1 PTARMIGAN BLVD.
LA(~LE RIVER, AK 9go ? ?-8736
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L' Street, Anchorage, Alaska 99502-06,50
SOILS LOG -- PERCOLATION TEST
!
2
3
4
5
7
8
9
10
,11
12
13
14
15
16
17
18
19
20
COMMENTS
DATE PERFORMED:
WAS GROUND WATER
ENCOUNTERED?
S
L
IF YES, AT WHAT 0
DEPTH? P
E
SLOPE SITE PLAN
Depth Ia Walm' Alter
Moniloring?
/
Gross Net Depth to Net
Reading Dote Time Time Water Drop
PERCOLATION RATE 7°~z' Immures/tach) PERC HOLE DIAMETER
-- TEST. UN,ETWEEN ,T
AND
/ ~/
ACCORDANCE WITH ALL STATE ~D MUNICIPAL ~DELINES IN EFFECT ON THIS DATE. DATE:
72~ (R~. ~)
Municipality el Anchorage ,..
DEPARTMENT OF HEALTH & HUMAN SERVICES ,'~*"~"*,-.*.*.,,*~**
, ~
~25"L" S~,ee~, An~,orage, Am,~a ~9~02-0~50 [~~?.~~
SOILS LOG ~ PEHCOLATION TEST ~.~ -]..
PERFORMED FOR: ~D/~ DATE PERFORMED:
LEGAL DESCRIPTION: ~~~ ~/ ~/~Township, Range, Section: ~/~/
SLO.E S,TE PLAN
WAS GROUND WATER .~/
ENCOUNTERED?
! -
IF YES, AT WHAT
12
Oeplh to Walm' kJter
13 MonilorinD? ~'~£~
Reading Date Gross Net Depth to Net
Time Time Water Drop
14
16
17
18
19
2O
PERCOLATION RATE /"~' ?B tm,nutes/,nch) PERC HOLE DIAMETER ~ /''
/
COMMENTS
ACCORDANCE WITH ALL STATE A~D MUNICIPAL ~IDELINES IN EFFECT ON THIS DATE. DATE:
(Rev,