BENITO BLK 3 LT 7
0~o \l 0o0 oGREAT · ANCHORAGE AREA BOR0"';H Department of Environmental Quality 3500 Tudor Road Anchorage, Alaska gg$07 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE NUMBER OF FROM WELL ~'~'"z7 / MANUFACTURER~~,~f MATERIALc~-~/~'~',~OO COMPARTMENTS INSIDE LENGTH INSIDE WIDTH --' LIQUID DEPTH ~- .LIQUID CAPACITY /~2,~~:~ GALLONS. SEEPAGE PIT: NUMBER OF PITS ./ DIAMETER MATERIAL /----~.~ CRIB SIZE: LINING BUILDING FOUNDATION OR WIDTH/~-/, LENGTH/___~f DEPTH DIAMETER~.a~_DEPTH ~/ DISTANCE FROM: WELL TOTAL EFFECTIVE NEAREST LOT LINE. O / ABSORPTION AREA (WALL AREA) ~.~"~-"~ SQ. FT. ADDITIONAL ABSORPTION BUILDING NEAREST FOUNDATION ~' , LOT LINE CESSPOOL ~' , OTHER SOURCES APPROVED DISAPPROVED NEAREST SEWER LINE DEPTH ~-- DISTANCE FROM: SEPTIC / SEEPAGE , TANK ~'7 SYSTEM /-~ ! REMARKS INSTALLED BY: PIPE MATERIAL: LOT SLOPE: REMARKS: Form PW-026 DIAGRAM OF SYSTEM DATE GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3500 TDD©R ROAD POUCH 6-650 ANCHORAGE. ALASKA 99'502 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT NAME OF APPLICANT INSTALLATION LOCATION INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED SOIL TEST RESULTS /---'""-- OTHER SEEPAGE PiT DRAIN FIELD NOTE~ THIS PEH~IT lB HOT VALID WITHOUT COMPLETION DATE ANTICIPATED pFRHTT VAI TD ('}NF YFAR FINAL INSPECTION~ 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL IN~PE~¥iON BY TH~- HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE TYPE~] O~ crtrtc'~eSEEPAGE AREA SIZE TYPE MINIMUM DISTANCES, Rw'QUIREMwNTS FOUNDATION TO SEPTIC TANK 20 f~e DRAIN FIELD _ ].0 FOUNDATION TO SEEPAGE PIT SEPTIC TANK TO SEEPAGE PIT WALL _ 15 f'['' f SEPTIC TANK 5 f~. , SEEPAGE PIT 20 f~. DRAI~ FIELD ~ TO ~EAE[ST LOT LINE. WELL TO SEPTIC TANK , DRAIN FIELD //~ / WATER MAIN TO SEPTIC TANK 10 f~t ' DRAIN FIELD [0 TO RIVER, LAKE. STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF ............. lI~FI V H1UM. * ALSO CONSIDER AREA WELLS. /~ c-~ EXCAVATION S FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL ]BACKFILL, CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION· HEALTH AUTHORITY OR LICENSED DESIGNER DIAGRAM OF SYSTEM ' ~" £A~T IRON .~IPIION · St-PT1C PIPE I~llll AIRTI6HT CRIB .~/' ~ (I ~7 ........ ~z~ .... l:::::.'~ t~,~. ~ N /' ','::;:',t:~-:~-1~::5:1 . i~ o I...~., I: ..... h ;:. ~'H fl ] P,U;' ' II]fll HUH I' "". % ,, C I requ~rc, d i.~lleflcver line crosses (CRIB 4' HINI~UH A801'[' LATER.; undcr dr~ ve~'~y. TABLE) 60fiSI[HR AREA ~ELtS, SEEf'/~6E Pi1 E~CAVATIOII BASED ON '~}:LL SOIL f I*' I",'; f;X-' '~70' io PIT- 100' "tO T/~!;K- P,O" TO FJ'I- 4{)'-fiO' 0HL'f I. 1'(I ~A~fK- 200' Ill PiT - 200' J er 114" pr fuoz " I except I0' prec~udir .... I tank & tha. should J 6" per 100 on flat CAST l~Otl~ ~/SEPT1C DISTL!PD£D/"--'"'~'~ LEAST IRON $1PtION PIPE I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF (~REATER ANCHORAGE /~REA BOROUGH ORDINANCE NO. 2B.SS AND THAT THE ABOVE DESCRIBED SYSTEM lB IN ACCORDANCE WITH SAID CODE. DATE, /~-~/~'~.~-? APPLICANT'S SIGNATURE ~ #1: Time Date Insp MUNICIPALITY OF ANCHORAGE OF HEALTH AND ENVIRONMEN L Street, Anchorao~, AlasKa 264-4720 Date Received: #2: Time Date / Insp / PROTECTION 99501 March 22, 1978 #3: Time Date Insp REQUEST FOR APPROVAL OF IND] :R AND WATER FACILITIES / 1. Lending Institution Request: Fi] ,,.:ion Mailing Address: 207 Phone: 276-0117 Property Addres~ [ones Phone: 688-3014 3. Legal Lot 7 3 Benito Subdivision,, Resi~nce: Number 4: Single Fam ( ) o~/=~rooms: Multi dence: (x) ooms: Four 5. Well Syst~m~/ .Individual Well (x~~y/Public System() t/ ~epth °~/~11 // Well Log on File ( ) Permit # /~ /~ 'n /} I ~ _/"/~'~// Constructid~ Bacterial Analysis 6. Sewage Disposal /y t~~ On-siLe System ( ) Public Utility (x) Permit # l _~~alled Installer Septic Tank Size Manufacturer Absorption Area Soils Rate Material Distances: Well to Septic Tank to Sewer Line Nearest Lot line to Nearest Lot Line to Absorption Area Absorption Area Page Two Department of Health and Environmental Protection Request for Approval of Individual Sewer and Water Facilities Legal Description: Lot 7 Block 3 Benito Subdivision Comments: Affadavit Attached: ( ) Letter Attached' Approved: Date: Disapproved: Date: ( ) Department Worksheet: MUNICIPALITY OF ANCHORAGL of Health and Environmental Protection . Department 825 L Street, Anchorage, Alaska 264-4720 99501 ~ ~equest for Approval of Individual Sewer and Water Facilities 1. Property Owner: Peter & Mary Jones Mailing Address: Box 832 Eagle River~ AK 99577 Phone: 68~-3014 Name of Buyer: WOODS, William L. & Carole (Jr.) Mailing Address: 1633 Wickersham Anchorage, AK 99507 Phone: -_~__ Lending Institution: Alaska 1st Mortgage Corp. Mailing Address: 207 E. Northern Lts Blvd Phone: 276-0117 Realtor/Agent: John Russell Executive Realty Mailing Address: Eagle River, AK Phone: 694-3053 Legal Description: Lot 7, Blk 3~ Benito Subdivision Street Location: NHN Bearpaw Circle Single Family Residence: ( ) Number of Bedrooms: Multiple Family Residence: (X) Number of Bedrooms: 4 Water Supply: *Individual Well ~ If Individual Well, well depth If Community System, name of system Public/Community System ~ ) Sewage Disposal System: *~n-site System ( ) If On-site System, date of installation: Public System ( ) *NOTE: A well log is required on ALL wells drilled since 6/75. ** If on-site sewer system is over two(2) years old, an adequacy test is required by this department. A fee of $25.00 must accompany each request before processing can be initiated. 3/77 / / / / / / / ~L // T° Florence I AT Fifth Floor suBJEcT Ref~d: Lot ? Block 3 ~enito The attache~ paperwork is being submitte~ for a refund. I DATE March 31' I978 The bank Ca11~ this morning, March 31, 1978, for a cancellation. Pleaee process the neueSsary request and refund the money to the lending agency. Thank you. DuPLiCATE DATE I SIGNED gedi~orm O SEND PARTS I AND 3 WITH CARBON INTACT 4S 469 PAR~ 3 WILL BE RETURNED WITH REPLY · Poly Pak (50 sets) 4P469 DETACH AND FILE FOR FOLLOW-UP GREATE ,{ ANCHORAGE AREA B( .',OUGH 3330 C STREET, ANCHORAGE, ALASKA 99503 DEPARTMENT OF ENVIRONMENTAL QUALITY 274-456 ! March 25, 1975 File No.: 4-1 Mr. Peter Jones P.O. Box 832 Eagle River', Alaska Dear Mr. Jones: 99577 It has been brought to our attention that public sewer is available to Block 3, Lot 7, Benito Subdivision. According to Greater Anchorage Area Borough Ordinance, Chapter 16, Article 16.45, Section 16.45.050: "Septic tank-seepage system sewage disposal facilities shall not be installed.or used on any premises where sanitary sewers are available within seventy (70) feet of the nearest lot line of said premises ...". The Greater Anchorage Area Borough Public Works Department has checked their records and they indicate that your structure (s) is not connected to the sanitary sewer. Would you please check your records to verify that the structure (s) is or is not connected and notify us immediately if your records indicate that a connection has been made. If we do not hear from you within seven (7) days, we will.assume that our records are correct. We, therefore, request you connect any and all structures located on the subject property to public sewer during the 1975 construction season. You must apply for a connection permit from the permit officer for the Greater Anchorage Area Borough, 3500 East Tudor Road. If you have any questions regarding the above, please do not hesitate to contact the permit officer at 279-8686, extension 259, or the Department of Environmental Quality at 274-4561, extension 141. Eagle River District Sanitarian JL/lw RECEIPT FOR CERTIFIED MAIL--30(~ (plus postage) SENT TO POSTMARK OR DATE STREET AND NO. P.O,, STATE AND ZIP CODE '- __ OPTI_ONAL~S_E~RVICE_S_FOR ADDITIONAL FEES RETURN ~, 1. Shows to whom and date delivered ........... With delivery to addressee only ............ 65¢ RECEIPT p 2. Shows to whom date and where delivered .. 35¢ SERVICES With delivery to addressee on y ............ 85¢ -D ELI V_E R- *~O--AD DR ESS E E ONLY .... :.:..: :....::~._~..,_.._::::.:.._,:.._...:.. SPECIAL DELIVERY (extra fee required) .................................... PS Form NO INSURANCE COVERAGE PROVIDED-- (See other side) Apr. 1971 3800 NOT FOR INTERNATIONAL MAIL ~ GPO: 19'72 0 - 460-743