Loading...
HomeMy WebLinkAboutBERNARD BLK 3 LT 18AOnsite File IM Lot A's ;WU OW 4M 0 dAgmhI =a i Atf AMOS A 'Time r ''; Conf both use. confirm sev%aration WITn survey.0 . 2 Certified Drilling Log OWNER OF LAND: Kim & Martin Bassett ADDRESS: 7850 Stewart Mountain Drive Eagle River, AK Bore Hole Data Depth From To LEGAL DESCRIPTION Bernard Block 3 Lot 18A DATE: 5-29-19 0 2 PERMIT NUMBER: OSP191034 DATE OF ISSUE: 2-27-19 TAX IDENTIFICATION NUMBER 06032128000 Is well located at approved permit location: ❑Yes ❑No Method of Drilling: Mair rotary Ficable tool Depth of Well: 260' Casing Type: Steel wall thickness .250 inches Diameter: 6 inches, depth 44 feet Liner type Static Water Level: 70 feet Recovery Rate 7 ® gpm gph Method of Testing Air Well Intake Opening Type: 1-1open end ®open hole ❑ Screened Start feet Stopped ❑ Perforations Start feet Stopped Grout Type: Bentonite Volume: 50 lbs Depth: from 2 feet, to 42 feet Well Disinfected Upon Completion: ®yes ❑ no Method of Disinfection: Chlorine 50 PPM Comments: 2 4 4 21 21 39 39 47 47 202 202 224 224 237 237 249 249 260 Casing Stickup Overburden Tight Silty Sand & Gravel Heavily Broken/Weathered Bedrock Broken Bedrock Bedrock Gray Bedrock Gray w/ Quartz Bedrock Gray Bedrock Gray Mostly Quartz Bedrock Gray w/ Quartz Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Humah Services and/or Department of Environmental Conservation. Matsu Borough: Department of Environmental Conservation. DOC s .. ,? 1 �c . 6ti. `� x4 � ,� *,. ,makE� ULLIVAN F, M� �' �` '�a PO.Box670269,Chugiak,AK99567 888-2759 Pump Installation Log Well Drilling Permit Number: SW OSPI91034of Parcel Identification•' 06032128000 Legal Description Bernard Block 3 Lot 18A 11 Pump Installation Date: 6-5-19 11 Pump Intake Depth Below Top of Well Casing: 230 11 Pump manufacturer's Name: F&W 11 Pump Model: 4F07P07301S 11 Pump Size: 3/4 11 Pitless Adapter Burial Depth: 10 Pitless Adapter Installer: Northern Excavating Disinfected Upon Completion? ® yes ❑ no Method of Disinfection: Chlorine 50 PPM II Comments: Pitless Manufacturer: Martinson 11 Pump Installers Name: Sullivan Water Wells Property Owner Name & Address Kim & Martin Bassett feet hp feet Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. "T� MUNICIPALITY OF ANCHORAGE JN O,e ,,`�1 l n ��� On-Site Water&Wastewater Program c•,` (.^"``5(:. PO Box 196650 4700 Elmore Road ` '. Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax (907)343-7997 y • �; MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water& Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 060-321-28 Property owner(s) Martin and Kimberly Bassett Day phone 907-694-3917 Mailing address 7850 Stewart Mountain Dr., Eagle River, AK 99577 Site address same Legal description (Sub'd., Block & Lot) Bernard, Block 3. Lot 18A Legal description (Township, Range & Section) Lot Size 66.081 Sq. Ft. Number of Bedrooms 6 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (M all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) El (w/wo ADU) Septic Tank ❑ Upgrade ® Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well Water Storage U THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above inform 'on is correct. I further certify that this is in accordance with applicable Municipal Codes. '6 m C. 66 -1P--- (Si n. u - of property_,..rner •r authorized agent) Permit/Rush Fees: yF usnOD Waiver Fees: Date of Payment: 046)1 161 Date of Payment: Receipt Number: (lea-4 24 I Receipt Number: Permit No. Of P 1411 034 Waiver No. G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc . - Municipality of Anchorage Page 2 of 3 DEVEOPMENT SERVICES DEPARTMENT. 4700 South Bragaw Street Anchorage,AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report PID No. 060-321-28 Permit Number: SW020091 oad) 1 rd� , pc\a .,......-;.... ..;::„.-!,;.,.a.--..,117.?..,.,„. ra::: C4 `�:'�• ® // S1 =a.. M 1 .a-•#:��• t.,d:rt(• ...,-.-9,:, ,R<rl.. N A B7.4 w r S 1 62.7 78.9 . "`'::',41i S2 69.9 87.3 (11/4:•?''‘'I::.:llt////////////////i: l x Be • ;3µi;, ZNi C4 101.3 90.7 Hom C5 150.5 1 17.5 u) • • • M 1 101 .0 89.8 " "'�_ C3 79.88� ® ,'��;t` :s'�'�:.,.t..;`,: ��xti�;:4 ^ Well ..Se =tti tti� :„ ,• ,Itc5,12.4* 41 A i�( YY Pro P �� :.:N•_ 41 T,.. f 1,,,t �r. •t: 1.. tib.:,+:.''_1:.. :r!,�,"`....::.?. L. /Qrp. -:t ti' JYt:.:7;•*r (:'::,,..;.:4-!...,•-•�� StIQ'a . 1 8A ... • • , O.00 - ,7 , , f roroSed trlo.l will me€.4 cI( er.�r.I yid 5e 'a�0.1,15 15i1nc ) we.11 ut\( be ei-her' PLAN AS-BUILT decbml or u til $el(n and StAb . SCALE 1 " = 40' • own3tr1y‘c1-0n 441 ho-wit , g'l o c k.. 5, Loo- (gA 6;yy►trec* 60 2 ! � sem . y • z� =41' ;` `. y 5A ,,1.. : „ +`..� tTi :: "'E"tyi+ JLC. a> 1e� ♦, �`,' • 1 • x t t., 1037...-' '**1- !nie, .-.1. ,Y,•42�" r^ Onoa', c x� . 4s.°° 1 1 Community Water S tea a „all / $i(ti, in s/ 0 / La 6�7 / 'L Y, i a `. Y o B i§g;S �(Y Cvl..>.. ia'tJll. ti.� •i JO. ``f` O��// / d "fFf,3" '.,�F ,l."...'- ff" '4it int :'%sem i0,{> N� .hr�v's: ,w.‘,..,,,,.. ...,„,41,..,,,r*H. ,,r,..,,,,,,,, ..,,,,,,,,,,,f. ,..,...., SS • 237.02 f�� " Wit+ 19A . :•, ..' ±, m vt 2 ; Vacant . ,; It3i ... riiii r4 I Is�v W�+1►- ."�"'� ••ti, s: e� •,PY^* _.'rL, tt.,1,o °'�i. 1:'': ', 7 1. 'r`gi;.1,1,. u�j 4 •... '� ,�...4.,., fS/tits 14,�/h_i�— 's- �'r ,^h• : "' •ti,'"l• x.,1�4�'; tri � `�rg.%.T� 'i: "hitt.•� ,� ° ;•• •••tri, ' „7,':' s -,1, �' A r L ',ii,' f_irJ=, ":11;0111/1.7a- •yfefti '. ‘''''10,' rt"' R °' e• .i'` 1 13`10,. 5 -1-Qrss4 r Armin i••••a' -r1 ''> k'.. _ •; � h� "'°t: 4.:t r(. t',,�' :• i I�'. � i� , �: A.:i '`L� ��"� fi L.y.�• �� a �c2������. a•1 , i - .c'. f .��` prail , d .S <,,,. ,�,{ � .' '� �{it.�ia. >~T F1 � r > ', '.� •'1"� '��.of�+� '" .� y, Q� •,a" :� 35 )- %"�'.k .111130 1M;;/ga:li1/: 9, ,. f -Jj+}Rfn ;11. ut G i •14 `-'` 0.- -.1' .Aitwa y '4 , .#" s 'S:'. ' ,",,,F. '' 11will111IIfro'' ;s1.1• : : .4. ` M1 ..,..‘,,,,,of., o b:' 1' ,a. 1.-?4,- ',;',..V., ,'t, 1i.vsem,,. 4, "na a . . . ..,,....„0,,,4,,.......,e,..0,� � I . :''.. 4:44,.v.";- r e .� �� ISd ��^ t t�1` ' • ri ';Sz'`44"!'M•. i 11 9.*Y 4'T 4'...,tai r .. .4. Y.o i," 7,.. •a.�"U..o., , drlf r 7 �",, x.., 1 " Y. X � • s . . .'.11„, . �ih. ..,;'> '�..` +„ .a �,.Y s,1,,,;����. ,-.�znswa. . r. I Municipality of Anchorage Page i of 3 Development Services Department Onsite Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW020091 PID Number: 060-321-28 Name: Martin Bassett Wastewater System: New ®Upgrade Address: HC85 Box 9204 Eagle River AK 99577 ABSORPTION FIELD Phone: Number of Bedrooms: Deep Trench 694-3917 SIX 6 LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: 11 •8 GPD/Fl= Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 3 18A Bernard 3.5 R. 7.5 Ft. Township: Range: Section: Fill added above original grade: Gravel Length: - 1 Ft. 75 Ft. Well: Existing Gravel width: 3 Number of lines: 1 Distance between lines: N/A Ft. Ft. Gassification (Private, A. B. C): Total Depth: Cased to: Total absorption area: - Pipe Material: Ft. Ft. 1,125 n' ASTM D3034 PVC Driller: Date Drilled: Static Water Level: Installer: Date Installed: Ft. Tweed Excavating 6/13-14/2002 Yield: Pump Set al: Casing eight Above Ground: TANK GPM Fl. Ft. SEPARATION DISTANCES ® Septic' ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift - Holding ublic/Private anuac rer: paciny in sons: Fromil Tank Field Station Tank Sewer Line Anchorage Tank 2,000 well >100' >100' N/A N/A >25' Material: Steel N TwTwo (2)o (2) mens: Surface Water >100' >100' N/A N/A LIFT STATION — NONE ON LOT Lot Line >5' 1' N/A N/A ize: anu ac urer. Gal. >5' >10' N/A N/A 'Pump on' level at:in. 'Pump off" level at: High water alarm at: Foundation in. in. Make & Model Electrical Inspections performed by: Curtain Grain iNone lNotedPump Remarks:BENCH MARK ExistingSeptic Tank and Absorption Crib Pumped, 10.110n arm Description: Crushed, Backfilled and Abandoned On Site. See Lot Lower Level Slab. Line Waiver for Absorption Trench. Assumed Elevation: 100.0 Ft. - Engineer's Stamp It O�P.�' �F"�q i O Inspections performed by: Alan Harala Dates: let 6/13/02 : ` 49th 2nd 6/13,14/02 ................ Department of Health afld Human Services approval C MICHAEL F:. ANDERSON' ��. 0•• NO. CE-4381 ; �_- ��i��F'• Reviewed and approved by: P4zf Date: 3 -30'1 ,,w��: Municipality of Anchorage Page of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SW020091 PID No.: 060-321-28 House Lower Level TBM EI. 100.0 N i 4 PROFILE AS—BUILT 's�R . -Scale: V= 10' .6` MICHAEL E. ANDERSON 1. No. CE -4381 April 28, 2003 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 18B, Block 3, Bernard Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The absorption trench recently constructed on Lot 18B, Block 3, Bernard Subdivision was placed within 1' of the west lot line to increase separation distance between the trench and the cut slope to the north. Sufficient area exists on the property to the west for placement of an original and replacement absorption system. In addition, soils in the area consist of silty sand and gravel, which absorb water at rates considered good for absorption of septic effluent. No conflicts exist between the absorption trench and the well on the property or with the proposed well to the west. All required separation distances can be met between the new trench location and all wells and septic systems in the area. We therefore recommend a waiver be issued allowing the new trench to be located 1' from the west property line. Sincerely, /� n Michael E. Anderson, P.E. .c�).,• i. 49th � ••''s*1 MICHAEL E. ANDERSON No. CE -4381 4 George P. Wuerch, Mayor 5/21/2003 Anchorage Municipality of Anchorage All -America Building Safety Division ' I 1111 2002 Anderson Engineering Anchorage, Ak 99524 Subject: Waiver Request for Bernard Block 3 Lot 18A Waiver Request #WR030038 Parcel ID #060-321-28 SW020091 Dear Mr. Anderson: Your request for a waiver of the required 10 feet horizontal separation from the absorption field to property line has been approved. The approved separation distance is 1.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, hoz T C'ooja`� Joe Goodall Civil Engineer On -Site Water & Wastewater Program P.O. Box 196650 • Anchorage, Alaska. 99519-6650 • Telephone: (907) 343-8301 • Fax: (907) 343-8200 4700 South Bragaw Street • Anchorage, Alaska 99507 http://ww ,.ci.anehorage.ali.us Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw, Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 Waiver Review Worksheet WR#: 030038 PID#: 060-321-28 HAM Permit#: sw020091 Date Received: 5/21103 Legal Description: Bernard Block 3 Lot 18A Engineer: Anderson Engineering Applicant: Martin Bassett Waiver Requested: 1' Lot Line Waiver Criteria: Geology A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: Points: ..............................................................................� Waiver is Granted: Waiver is not Granted., List Conditions or Reasons for above: Date: 3 �% _ ! By: ....................................... Rec#:03 7 / 7GAmount: $150.00 Date Paid: V� • 3 ............................., MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW020091 Legal Description: BERNARD BLK 3 LT 18A Design Engineer: 0014 Anderson Engineering Owner Name: Martin Bassett Owner Address: HC85 Box 9204 Eagle River , AK 99577 - /Z1SOP a' 7'2�r� Date Issued: May 06, 2002 Expiration Date: May 06, 2003 Parcel ID: 060-321-28 Site Address: Lot Size: 66081 SQ. FT. Total Bedrooms: 6 Permit Bedrooms: 6 This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank Holding Tank ❑Privy All construction must be in accordance with: 1. The attached approved design. ❑ Private Well ❑ Water Storage 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: �—Q 2 - Date: 6 0 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 060-321-28 Permit Number SW07-00 91 Property owner(s) Martin Bassett Day phone 694.3917 Mailing address (1) HC85 Box 9204 Eaple River, AK 99577 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 18A, Block 3, Bernard Subdivision Legal description (Section, Township & Range) Lot Size b&) a / Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms Six (6) Sewer Only ❑ Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. El (Signature of property owner or authorized agent) so Permit Fees: Waiver Fees: Date of Payment: IL[- M --0 f__ Date of Payment: Receipt Number: 0/ go q bt Receipt Number: (Rev. 12/00) April 29, 2002 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 18A, Block 3, Bernard Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 18A, Block 3, Bernard Subdivision intends to upgrade the existing home on the lot to six bedrooms. The existing septic system, constructed in 1976 was only designed to serve a three-bedroom home. We are therefore requesting a permit be issued for the construction of a new septic system to serve the much larger home. The attached Site Plan and backup documentation identify the location and configuration of the new septic system and the parameters used in the design. Also identified on the plans are the location of the well on the lot, test hole locations and the location of the existing septic tank and absorption crib. Only the lot to the east of this property is developed, but the well and septic system do not conflict with the improvements planned for this lot. Existing drainage patterns are shown and will not be altered by the development of the lot. The test holes placed near the location of the proposed absorption trench indicate silty gravel with some sand. The percolation tests completed in the material resulted in rates of 10 to 11 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. We are therefore proposing to place a 3' wide deep absorption trench system with 7.5' of gravel beneath the distribution pipe. The total depth of the trench will be 12.5'. The distribution pipe will be placed at 5' below the ground surface to provide sufficient drop from the septic tank to the absorption trench. The ground surface on the lot slopes as shown on the attached Site Plan with an approximate 20% to 30% slope from south to north. It is necessary, therefore, to place the distribution pipe 5' below the surface. Extending the 25% line from 2' above the distribution pipe it will not daylight with less than 40' of clearance from the trench. The new absorption trench will be constructed in conformance with Municipal requirements and parallel to ground contours where possible. All components of the new septic system will be constructed a minimum of 100' from the well on the lot and 10' from the service line from the well to the house. Lot 18A, Block 3, Bernard Subdivision April 29, 2002 Page Two If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincery, (f a'—J, Michael E. Anderson, P.E. Attachments 49th GV 'i MICHAEL E. ANDERSON M, Cr -alai , !'ROFESS���i rel � I �I I I I I i I --I �I----------- J THIS PROJECT O Q AREA SYSTEM PLAN SCALE 1" =100' 49th ............ . ...... MICHAEL E. ANDERSON No. CE -4351 M6 w H w yy5* h �.✓S. IzzzL;7 a Dov 1 138.04-j s> MP, � Y n N zrz o EI Y I THIS PROJECT O Q AREA SYSTEM PLAN SCALE 1" =100' 49th ............ . ...... MICHAEL E. ANDERSON No. CE -4351 AREA SYSTEM PLAN SCALE 1" =100' 49th ............ . ...... MICHAEL E. ANDERSON No. CE -4351 LOT 18A, BLOCK 3, BERNARD SUBDIVISION SCOPE OF WORK: ROAD Exi.sti n _ - - - - 280.00 1. Pump and Remove Existing Septic Tank. 2. Pump, Crush and Backfill Existing Absorption Crib. 3. Intercept Existing Sewer Service Line at Foundation. Place Foundation Cleanout. 4. Place New 2,000 Gallon Septic Tank. 5. Construct New 75' Long X 3' Wide X 7.5' Effective Depth Absorption Trench. 6. Flatten Slope Downhill From New Trench. 7. Regrade All Disturbed Areas. 8. Revegetate Area As Required. SITE PLAN SCALE 11' = 40' j 49th MICHAEL E. ANDERSON No. CE -4381. LOT 18A, BLOCK 3, BERNARD SUBDIVISION DESIGN FACTORS: Six Bedroom Home Perc. Rate: 10 MinJlnch Avg. Application Rate: .8 GPD/SF SYSTEM REQUIREMENTS: Deep Trench System 2,000 Gallon Septic Tank 7.5' Drain Field Rock 6 Bedrooms X 150 GPD /.8 GPD/SF = 1,125 SF of Absorption Area 1,125 SF/15 SF/LF = 75 LF Trench Length Therefore: Construct An Absorption Trench 75' in Length by 3' Wide With 7.5' of Drainfield Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 5' Below Existing Ground. Total Depth of Trench to Be 12.5' Below Existing Surface. Mound Over Trench to Provide a Minimum of 3' of Cover for Frost Protection. 4. 5' .5' 7.5' -� Natural f Backfill ti r i 111 Geotextile Fabric 4" Perforated PVC Schedule 40 �o Drainfield Rock 3 F ' TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 10' From Lot Line. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 10' Separation From Water Service Line. a: 49th MICHAEL E. ANDERSON No. CE -4381 i MEMORANDUM DATE: May 5, 2002 TO: Dan Roth �nn FROM: Mike Anderson, P.E. 6` 1 SUBJECT: Lot 18A, Block 3, Bernard Subdivision Septic System Upgrade Design and Permit Application The toe of the cut slope at the driveway serving Lot 18A, Block 3, Bernard Subdivision is approximately 3'-5' outside the property line. The top of the cut slope is 5'-6' above the toe and slightly outside the property line. The ground surface from the top of the cut bank to the location of Test Hole No. 2 was measured at 20% to 22%. A drawing showing the cross section of the slope at Test Hole No. 2 and the proposed absorption trench is attached. This drawing shows the elevations and distances at strategic points on the slope. This data further implies that it is possible to construct the absorption trench as designed and still maintain a separation distance of 50' from any 25% break in grade. We are therefore confident the absorption trench meets all the requirements of the Municipal ordinance. We have left the total depth of the absorption trench at 12.5' as measured from the uphill side of the trench. The ground surface at the top of the trench will be approximately 9" lower on the downhill side of the trench and the total depth on that side will be 11.5'. This depth will more than satisfy the requirements for separation from a break in grade greater than 25%. -ANDERSON ENGINEERING P.O. Box 240773 ANCHORAGE, AK 99524 (907) 522-7773 Cell (907) 441-4000 JOB �a"r Igii 1i uL. 3,.$6w Avw SHEET OF CALCULATED BV / ✓ 1 DATE 57-6-107- CHECKED -S10ZCHECKED BY DATE 11 Municipality of Anchorage Development Services Department/Building Safety Division Onsite Water and Wastewater Program 4700 South Bragaw Street Anch., AK 99519 SOILS LOG - PERCOLATION TEST Performed For: Martin Bassett Date Performed: 4/18/02 Legal Description: LQJ 18A Block 3. Bernard Subdivision SLOPE SITE PLAN 1 2 11 12 13 14 17 18 21 OG/OL TESTHOLE NO.1 GM Tan/Olive 12%-18% Silt South Was Groundwater Encountered? No GP Lenses If Yes, What Depth? Depth to Water Cobbles After Monitoring 1.5"-7" Date: Some 12" Bottom of Test Hole Perc. Rate: 10 Min./Inch Pere. Hole Diameter. 6" Test Run Between 5 Ft. and 6 Ft. Comments: Pem. Cavity Presoaked Prior to Test. Performed By: Alan Harala, I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 4/28/02 See Site Plan - 49 IAEL E. ANDERSON NO. CE -4381 Reading Date Gross Time Net Time Depth To Net Water Drop 1 18 -Apr 2:08 2.25" 2 2:38 30 5.375" 3.12- 3 2:39 2.25" 4 3:09 30 5.25" 3" 5 3:10 -2- 6 3:40 1 30 5" 3" r} Municipality of Anchorage Development Services Department/Building Safety Division Onsite Water and Wastewater Program 4700 South Bragaw Street Anch., AK 99519 SOILS LOG - PERCOLATION TEST Performed For: Martin Bassett Date Performed: Legal Description: Lot 18A Block 3 Bernard Subdivision SLOPE SITE PLAN 1 3 4 5 6 7 15 16 17 21 OG/OL TESTHOLE NO 2 GM Rust/Brown 15%-18% Silt South Was Groundwater Encountered? No GP Lenses If Yes, What Depth? Depth to Water Cobbles After Monitoring 1.5"-8" Date: 5�ANow4E Some 12" Bottom of Test Hole Perc. Rate: 10 MinJlnch Perc. Hole Diameter. 6" Test Run Between 5 Ft. and 6 Ft. Comments: Perc. Cavity Presoaked Prior to Test. Performed By: Alan Harala, I, Michael E Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 4/28/02 See Site Plan 4/181( Reading Date Gross Time Net Time Depth To Water Net Drop 1 18 -Apr 3:46 7.5" 2 4:16 30 10.63" 3.12" 3 4:17 7.56 4 4:47 30 10.63" 3.07" 5 4:48 7.5" 6 5:18 30 10.5" 3" 0 Municipality of Anchorage Development Services Department/Building Safety Division Onsite Water and Wastewater Program 4700 South Bragaw Street Anch., AK 99519 SOILS LOG - PERCOLATION TEST Performed For: Martin Bassett Date Performed: 4118/02 Legal Description: Lot 18A. Block 3. Bernard Subdivision SLOPE SITE PLAN 1 10 11 12 13 21 OG/OL Fill Debris TESTHOLE NO. 3 GM Rust/Brown 15%-18% Silt North South Was Groundwater Encountered? No S GP Lenses If Yes, What Depth? L Depth to Water O Cobbles After Monitoring S QZ P 1.5'-8" Date: AW&K E Some 12" Bottom of Test Hole Perc. Rate: 10 Min./Inch Pere. Hole Diameter. 6" Test Run Between 6 Ft. and 7 Ft. Comments: Perc. Cavity Presoaked Prior to Test. Performed By: Alan Harala, 1, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 4128102 See Site Plan MICHAEL E. ANDERSON " NO. CE -4381 j Reading Date Gross Time Net Time Depth To Net Water Drop 1 18 -Apr 3:50 4.38" 2 4:20 30 7.5" 3.12" 3 4:21 4.5" 4 4:51 30 7.5" 3" 5 4:52 4.38" 6 5:22 30 7.38" 3" Otm GREOR ANCHORAGE AREA BOAGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 SEPTIC TANK: DISTANCE q FROM WELL NUMBER OF MANUFACTURER MATERIAL COMPARTMENTS d C INSIDE LENGTH I WIDTH LIQUID DEPTH LIQUID �CAPAC ITY P GALLONS. a DISTANCE FROM WELL / 6e) FOUNDATION NEAREST LOT LINE NUMBER OF LINES DISTANCE BETWEEN LINES TRENCH WIDTH ABSORPTION AREA P DEPTH: TOP OF TILE TO FINISH GRADE SQ. FT. LENGTH OF EACH LINE — DEPTH OF FILTER MATERIAL BENEATH TILE TOTAL LENGTH OF LINES IN. TOTAL EFFECTIVE IN. ABOVE TILE IN. WELL: TYPE_ 1LC3;C CONSTRUCTION L' -i -?6- DEPTHT DISTANCE FROM: BUILDING NEAREST NEAREST SEPTIC SEEPAGE FOUNDATION LOT LINE , SEWER LINE , TANK , SYSTEM CESSPOOL , OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCES: DIAGRAM OF SYSTEM INSTALLED BY: � glylif �� SEWER LINE DEPTH: 0 (I PIPE MATERIAL: PL'd LOT SLOPE: REMARKS: DATE APPROVED.-_ / Form EQ -032 INNS-PECTIION REPORT ON-SITE DISPOSAL SYSTEM NAME-�'"'!'� LOCATION 'J`^'-' J1Y.�. .(i' /SEWAGE MAILING ADDRESS �'C G ✓r-Jr?%C 2_6 �n PHONE✓��'� - J� LEGAL DESCRIPTION +'7`Y� jO d� �iz-Pt /a'C� SEPTIC TANK: DISTANCE q FROM WELL NUMBER OF MANUFACTURER MATERIAL COMPARTMENTS d C INSIDE LENGTH I WIDTH LIQUID DEPTH LIQUID �CAPAC ITY P GALLONS. a DISTANCE FROM WELL / 6e) FOUNDATION NEAREST LOT LINE NUMBER OF LINES DISTANCE BETWEEN LINES TRENCH WIDTH ABSORPTION AREA P DEPTH: TOP OF TILE TO FINISH GRADE SQ. FT. LENGTH OF EACH LINE — DEPTH OF FILTER MATERIAL BENEATH TILE TOTAL LENGTH OF LINES IN. TOTAL EFFECTIVE IN. ABOVE TILE IN. WELL: TYPE_ 1LC3;C CONSTRUCTION L' -i -?6- DEPTHT DISTANCE FROM: BUILDING NEAREST NEAREST SEPTIC SEEPAGE FOUNDATION LOT LINE , SEWER LINE , TANK , SYSTEM CESSPOOL , OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCES: DIAGRAM OF SYSTEM INSTALLED BY: � glylif �� SEWER LINE DEPTH: 0 (I PIPE MATERIAL: PL'd LOT SLOPE: REMARKS: DATE APPROVED.-_ / Form EQ -032 No u. NAME OF APPLICANT INSTALLATION LOCATION LEGAL DESCRIPTION GREOR ANCHORAGE AREA BOIOGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH SOIL TEST RESULTS COMPLETION DATE ANTICIPATED PERMIT NO. MAILING ADDRESS L �4 PHC 7 I� I SEEPAGE PIT,DRAIN FIELD OTHER TO BE INSTALLED BY NOTEI THIS PERMIT 15 NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE TYPE SEEPAGE AREA SIZE MINIMUM DISTANCES, REQUIREMENTS_ FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT SEPTIC TANK TO SEEPAGE PIT WALL DRAIN FIELD SEPTIC TANK , SEEPAGE PIT DRAIN FIELD TO NEAREST LOT LINE. l �/'/1 WELL TO SEPTIC TANK. SEEPAGE PIT �'" `� + DRAIN FIELD ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK DRAIN FIELD SEEPAGE PIT SEPTIC TANK, , SEEPAGE PIT , DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL, 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. G.A.A.S. OR LICENSED DESIGNER TYPE DIAGRAM OF SYSTEM I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH O INANCE NO. 28.66 AND THAT THE ABOVE DESCRIBED SYSTEM II IN CGOORDANCE WITH SAID CODE. DATE �" 1 !—'? APPLICANT'S SIGNATURE EQ -016(3-75) LTJ 5. LEGAL DESCRIPTION /00 STREET LOCA/T�IjON I�7 1' MUNICIPALITY OF NUMBER OF BEDROOMS DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ❑ One ❑ Four ❑ Other 825 L Street - Anchorage, Alaska 99501 ❑ MULTIPLE FAMILY ENVIRONMENTAL ENGINEERING DIVISION 7. WATER SUPPLY Telephone 264-4720 *ATTACH WELL LOG. A well log is required for all wells drilled REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete requests will not he processed. Please allow ten (10) days for processing. 1. PROPERTY OWNER I ,JL( - PHONE MAILING AD RESS aex individual/on-site, give installation date LA ❑ PUBLIC UTILITY If If system is over two (2) years old an ade acy est is required by this Department. PROPERTY RESIDENT (If different from au ve) PHONE 2. BUYERPHONE ��S'Sc77- i<7 /!f MAILING ADDRESS 3. LENDING INSTITUT ON 1 �. �p PHONE MAILING ADDRESS�v/ 4. REALTO T PHONE MAILINGADDRASS LTJ 5. LEGAL DESCRIPTION /00 STREET LOCA/T�IjON I�7 ,t 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS SINGLE FAMILY ❑ One ❑ Four ❑ Other ❑ Two ❑ Five ❑ MULTIPLE FAMILY -�K Three ❑ Six 7. WATER SUPPLY ;E< INDIVIDUAL* *ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if. available.) 8. SEWAGE DISPOSAL SYSTEM INDIVIDUAL/ON-SITE" individual/on-site, give installation date LA ❑ PUBLIC UTILITY If If system is over two (2) years old an ade acy est is required by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. ,cviuwuw rM THIS SIDE FOR OFFICIAL USE ONLY INSPECTION APPOINTMENTS DATE RECEIVED TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE ❑ SINGLEFAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE ❑ OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON-SITE ❑PUBLIC UTILITY Connection Verified PERMIT NUMBER DATEINSTALLED INSTALLER ❑Septic Tank or ❑ Holding Tank Size: 00 If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER . -e " TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL T0: Septic/Holding Tank AbsorArea ption Li Sewer ne Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS ,[D- APPROVED FOR BEDROOMS Li CONDITIONAL APPROVAL (letter must accompany certificate) ❑ DISAPPROVED DATE r� \y - BY (Title) LEGAL DESCRIPTION 72-010 (Rev. 3/78) UNICIPALITY OF ANCHORAG )EPARTMEMWF HEALTH AND ENVIRONMENIISPROTECTION 825 L Street, Anchorage, Alaska 99501 279-2511, ext. 224 or 225 #1: Time 1 -10.00 a.m. Date Received: April 21, 1977 #2: Time #3: Time Date 4-22-77 Fri. Date Date Insp Dixson Insp Insp REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES 1. Lending Institution Request: First National Bank of Anchorage Mailing Address: Post Office Box 720 99510 Phone: 276-6300/491 2. Property Owner: Alvin/Violet Trihub Mailing Address: Star Route Box 9204 99577 3. Legal Description: 4: Single Family Residence: 'V_� 5 6. 7 Multiple Family Residence: ( ) Phone: 694-2673 Bernard Subdivision Number of Bedrooms: Number of Bedrooms: Well System: Public/Community System: ( ) Individual Well: Permit # Depth of Well J/ %% / Well Log on File Construction .�- Bacterial Analysis 7, le, Sewage Disposal System: On-site /System Public Utility ( ) Permit # / Installed (9 rl 126 Installer / Septic Tank Size Manufacturer Absorption AreaSoils Rate Material IA Distances: Well to Septic Tank p p U to Absorption Area to Sewer Line tX Nearest Lot line cf7 Absorption Area to Nearest Lot Line--f=— MUNICIPALITY OF ANCHORAGE �? AGR DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L Street, Anchorage, Alaska 99501 279-2511, ext. 224, 225 =� REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES 1. Type of Inspection: VA_.. _FHA____CONV xxxxx___ TRIHUB ALVIN 2. Property Owner:_____..__ Star Route Box 9204 Eagle River, AK 99577 Mailing Address: - Day Phone:... ------ S9_4-2673 _____. 3. Name of Buyer: Mailing Address: Day Phone 4. Name of Lending Institution:_k_'IRST NATIQ_KAL Mailing Address: P,.Q_,_Hox 720_ An_cl-Qr-age_AK-9J51CPhone:127.6--Ea4D—Ext_491__-_—... 5. Name of Realtor or Agent: Mailing Address: 6. Legal Description: Lots .17A-& 18A, Block 3, BERNARD SUBDIVISION Location: Stewart_ Road off_ Highland_D rive, Eaele_River Alaska _____ 7. Type of Facility to be 1 8. Water Supply Type of Supply: Public Uti If Individual, number of dwellings presently served If Individual, depth of well 9. Sewage Disposal System Type of System: Public Utility If Individual, date of installation 72-003(3/76) No. Bdrrns. Individual (on-site) Page Two ' Department of Health and Environmental Protection Request for Approval of Individual Sewer and Water Facilities Legal Description: Lot 17A and 18A Block 3 Bernard Subdivision Comments: Affadavit Attached: ( ) Approved: Disapproved: Department Worksheet: Letter Attached: ( ) Date: 441��26/% Date: GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received May 10, 1976 Time of :Inspection Sioo Pm PERCOLATION TEST Date of Inspection �, J%-�/ l/'iIts REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR c3i� P./VL. 1. Approval requested by: Mailing Address: Phone: _ 2. Property Owner: A - Phone: Mailing Address: 3. Legal Description: Lot 18A Block 3 Bernard Subdivison 4. Location: South Fork Road, off the MAE% Glenn Highway 5. Type of facility to be inspected Single Family No. of bedrooms 6. Well Data: A. Type B. Depth C. Construction D. Bacterial Analysis 7. Sewage Disposal System: R On-site system A. Installed B. Installer . C. Septic Tank: 1. Size 2. Manufacturer D. Seepage Pit: 1. Absorption Area 2. Material E. Disposal Field: Total length of lines 8. Distances: A. Well to: Septic tank Absorption area Sewer Lines , Nearest lot line Other contamination B. Foundation to septic tank , Absorption area C. Absorption area to nearest lot line EQ -034 (1/74) Page 1 of two pages ( Rage'2 of `two pages - Ret for Approval of Individual r &Water Facilities •wC®q scri pti¢;n Lot 18A Block 3 Bernard Subdivision Comment , -)fix_.rr Approved _ ... no Approval,Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM I certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ -034 (1/74) Glenn Highway, past weigh station, lst right turn (Ice Palace Road) about 2 1/10 miles in, South Fork Road; go about 100 yards past the road/sign that marks the Ice Palace, the road takes an incline, turn there, a green 64' trailer and he will be watching for you, told him what kind of car you had. The same guy you spoke to in the office on Monday morning.