HomeMy WebLinkAboutBERNARD BLK 4 LT H-1BBernard
Block 4
Lot H-iB
#060-321-25
SU WELLS
Domestic - Commercial - Geothermal
Phone 9117.888-2159
www.sueivanwaterweac.cem
Well Log
Permit Number: #SW 090096 Date of Issue 612612009 Parcel Identification Number: 080-321-25
Date Started: 911412009 Date Completed: 9/15/2009 Is well located at approved permit location? X iYes 1No
Property Description
BERNARD Lot H -1B Block 4
Property Owner Name & Address:
RUSS & JOYCE OLIN
PO BOX 771441 EAGLE RIVER, AK 99577
Section: Town: Range:
76
Borehole Data: Depth
Soil Type, Thickness & Water Strata From To
Casing Stickup 0 2
Overburden 2 8
Sand Gravel Silt 6 12
Gray Bedrock 12 28
Brown Bedrock Brokena 28 _ 49
Gray Bedrock 49 187
Gray & White Bedrock 187 280
Method of Drilling [X1 air rotary [1 cable tool
Casing type:
Wall thickness 0.25 inches
Diameter 6 inches Totai: 44 feet
Liner type:
Diameter inches Depth: feet
Casing stick-up above ground: 2 feet
Static Water:Level(from top of casing) 23 feet
Pumping Level: feet after
1 hours pumping _ gpm
Recovery Rate 5 gpm
Method of Testing: Air
Well Intake Opening Type
[ � Open End lX C Open Ho1e
n,. Screened Start feet Stopped feet
1 Perforations Start feet Stopped feet
Grout Type: Bentonite dry granular. Volume: 250 Pounds
Depth 44Start 0 feet Stopped 44 feet
Pump Intake Depth: feet
Pump size: HP brand name
Well disinfected upon Completion? [X Yes J No
Method of disinfection CHLORINE 50 PPM.
a
Water Sample Results:
Arsenic: ug1
Comments: WELL COMPLETION IN ACCORDANCE WITH
CURRENT MOA STANDARDS.
Well Driller:
Cole. Sullivan
Sullivan Water Walls:
P.O. Boz 670272
Chuglak, AK 99567'.
(9 07) 688-2759
Nitrates mg/l
Total Coliform Bacteria coloniesl100ml,
Other bacteria: col/100m1.
Attention: The property owner shall provide this log to DSD (onsite) and DNR within 30 daysof completion.
iii
cliria
s
ARCTIC PUMP & WELL INC.
jun Sullivan
PO Box 770197
Eagle River, AK 99577
(907) 688-2510
(907) 243-2282
iimaataLenomusna
Pump Installation Log
Well Drilling Permit Number: SW090096
Parcel Identification Number:
060-321-25
Date Of Issue: 6/26/2009
Legal Description Bernard
Lot:
Block:
H -1B
4
Property Owner Name Address:
Russ Olin
PO BX 771441
Eagle river AK
99577
Pump Installaion Date: 9/25/2009
Pump Intake Depth Below Top of Well Casing: 241
Pump Manufacturer's Name
Pump Model:
Pump Size:
Franklin
Constant Pressure System: 10-420
1.5HP
Pitless Adapter Burial Depth: 10
Pitless Adapter Manufacturer's Name Baker
Pitless Adapter Installer: U/K
Well Disinfected Upon Completion?
Method of Disinfection:
Comments:
Yes
Chlorine
Pump Installer Name:
Arctic Pump & Well, Inc.
Wednesday, August 13, 2014
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WATER SUPPLY PERMIT
Initial
Permit Number: SW090096
Legal Description: BERNARD BLK 4 LT H -1B
Design Engineer: 0855 GARNESS ENGINEERING GROUF
Owner Name: RUSS & JOYCE OLIN
Owner Address: PO BOX 771441
EAGLE RIVER , AK 99577-1441
Date Issued: Jun 26, 2009
Expiration Date: Jun 26, 2010
Parcel ID: 060-321-25
Site Address: 019090 ELNORA LN
Lot Size: 47792 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ).
g, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
A. Permit includes waiver WR090032 allowing an 88 foot well to septic system separation distance.
8/14/09 JC: Waiver revised to include permitted but not constructed septic system on Bernard Block 4 Lot H1A.
Received By:
Issued By. apvtP/4141 7
Municipality of Anchorage
P.O. Box 196650 • 4700 Elmore Road
Anchorage. Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997
http://www.muni.org/Onslte
Development Services Department
On -Site Water and Wastewater Program
• **** VARIANCE/WAIVER REVIEW ****
W R#: 090032 HA#: _ Permit#: 090096
PID#: 060-321-25
Legal Description: Bernard: Block 4: Lot H -1B
Engineer. GEG
Applicant: Russ & Joyce Olin
Your request for a waiver of the required 100 feet horizontal separation from the absorption
fields to the private well has been approved. The approved separation distance is 88 feet.
This waiver approval applies to the existing absorption fields to private well separation only.
Any future upgrade to the on-site wastewater disposal system will require all separation
distances be met or another approval from this department.
Waiver Is Granted: X Waiver is not Gra •� d:
Date: 8/14/2009 Approved b .6
Name of Reviewer
Rec#: 60224 Amount: $1.050.00 Date Paid: 8/14/09
**** VARIANCE/WAIVER REVIEW ****
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
wvrw.muni.orglonsite
(907) 343-7904
ON-SITE SEPTIC/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 212 <25 -
Ed-'-9�}3
Propertyowner(s)gCtSS � �/rO�/Cl' CN Day IYl V Phone
Mailing address�O•U. 7114 t F_.g.) AK Zip Code Tin
Site address 19040 E(y ovn )-.fit Cit Zip Code
t 9957i
71
Legal description (Sub'd, Block & Lot) Loi- i -A II- � See- Eine-Am/a CSL1.lIX'tI V(,� i QYI
Legal description (Township, Section & Range) 7V Y� .IR) 7T1`i.N) eS/cO AK
Lot Size 1-1ZYPSq. Ft. Number of Bedrooms
THIS APPLICATION IS FOR (®all that apply): THIS APPLICATION IS AN:
Absorption Field 0 Initial
Septic Tank 0 Upgrade
Holding Tank 0 Renewal
Privy 0
Private Well
Water Storage ❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Si.tu
L� J
of property owner or authorized agent)
Permit/Rush Fees: 1'15- Waiver Fees: -Y SOS()
Date of Payment: S I a D lob' Date of Payment: s 1 /041
41
Receipt Number: 9 t43tn Receipt Number: 06 0 Pa Y
(Rev. 11/05)
—piatagibr
GARNESS ENGINEERING GROUP, Ltd.
.a.Q+ CONSULTANTS & GENERAL CONTRACTORS rR
August 13, 2009 (REVISED)
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Attention: Jay Crewdson
Ref: Proposed Well and Waiver Request for Bernard Subdivision; Block 4, Lot HI -13.
Mr. Crewdson,
The existing 4 bedroom house is served by a community water system and a private septic
system. The community water system is scheduled to be decommissioned and all properties are
being required to have their own well drilled. It is our understanding that all the neighboring
properties past the referenced property, that are on the community water system, have drilled
their own wells and are no longer connected to the water system. It is also our understanding that
the owner originally submitted for a well permit and paid the MOA fee, but was directed to hire
an engineer to perform a site plan for the proposed well location due to the complexities
associated with his property. Per the request of the owner, we have prepared a site plan and
design drawing for a proposed well location.
As can be seen on the attached site plan and design drawings, we are proposing that the well be
drilled near the north property line and that we are requesting an 88 foot waiver from the
proposed well to his own drainfield and the proposed neighboring drainfield. Once the well is
drilled and water service is connected to the house, we are proposing that the community water
service line be decommissioned and abandoned in place by shutting off the water line with the
key box located in the northwest corner of the property. It is our understanding that the two
properties past the referenced property (north/northeast) have drilled their own wells and are no
longer connected to this water system. The well location was chosen after much discussion with
the owner and the well driller, Sullivan Water Wells, about existing site and soils conditions. The
area on the south side of the driveway was deemed to have very poor soils conditions in regards
to drilling the well and installing a water line/pitless. In short, this area was deemed to be
unsuitable for a well due to multiple factors. There are multiple undocumented foundations,
french, and curtain drains in this area which may be damaged by drilling in this area, potentially
causing surfacing of groundwater. Based upon this information, we have chose a well site to
minimize the risk of disturbing underground drains, undermining the garage foundation, and
potentially causing surfacing of groundwater. We have made a requirement for the owner and/or
well driller to have the well location staked to insure the well is drilled on property and meet the
88 feet from his own drainfield and the proposed neighboring drainfield (waiver requested).
3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259
Ph: (907) 337-6179 • Fax: (907) 338-3246 • Website: www.garnessengineering.com
We request you grant an 88 feet separation distance waiver from the proposed well to the
drainfield on the referenced property and the proposed drainfield on Lot H1 -A, Block 4; Bernard
S/D. The following items are justification for the waivers:
• The lot generally slopes from south to north. There is heavily vegetated between the well on
and the drainfield. If the septic systems were to overflow, it effluent would not travel toward
the well head.
• The location of the septic systems are or will be in a very visible area so that if any effluent
was to surface, it would be noticed and the problem corrected.
The other path of contamination is subsurface migration wastewater. As can be seen on the
attached well logs from neighboring wells, the well depth range from 240 to 340 feet deep and
there is approximately 40 feet of silty gravel and hardpan soils above the bedrock that have
served to inhibit the migration of untreated wastewater into the aquifer. Attached is a water
sample results from a neighboring well that is downhill from the septic system, which indicates
that there are no issues regarding nitrates or coliform bacteria. Based upon the aforementioned
facts, it appears that there is minimal risk associated with granting the request of a 88 feet
separation distance waiver.
If you have any qu= ions, please contact us at 337-6179. Thank you for your assistance.
Preside
M.S.
3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259
Ph: (907) 337-6179 • Fax: (907) 338-3246 • Website: www.gamessengineering.com
100' WELL RADIUS \�
1 BERNARD S/D:
/
BLOCK 2, LOT C2
PROPOSED WELL
•
BERNARD 5/D:
BLOCK 4, LOT 6
1
00• WELL RADIUS 1`—SEPTIC ARj
(APPROX. LOCATION) I
/
ISTINC COMMUNITY WATER UNE
BERNARD 5/D:
BLOCK 4, LOT SA
%ISTING SEPTIC SYSTEM
�i---�\ OPTIC ARES
BERNARD 5/0:
BLOCK 4, LOT H -1A
•
WELL
ARE
& SEPTIC ON LOT
PROPOSED AS OF
5/2/08
/
1'- —
- 100' WELL RADIUS — — —
/
BERNARD S/D:
BLOCK 3, LOT 17A
1
100' WELL RADIUS 1
EXISTING 4 BEDROOM HOUSE
BERNARD 5/1:0;
BLOCK 3, LOT 18A
BERNARD 5/0:
BLOCK 3, LOT ISA
5
E:
1' - 100
L-_
r--
"F—
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
701 [. 7000 0300. OUR 101 • Y40011/41. M OHO' • I10o[ (007).337-0171 • I4 (07)334-314 • RfSOT'. wow ,rsons.. 10
PREPARED FOR:
RUSS OLIN
PHONE NUMBER:
227-4943
LEGAL DESCRPTION:
BERNARD S/D; BLOCK 4. LOT H1 -B
PACE NUMBER:
1 OF 2
DRAWN 8Y:
J.L.M.
TYPE OF WORK:
SITE PLAN FOR PROPOSED WELL LOCATION
DATE; REVISED
8/13/2009
(Rev.0I4 5)
1 I
1 __- 1 / 1
I EXISTING COMMUNITY WATER UNE. I
1...,' WATER UNE TO BE DECOMMISSIONED
NOTE: THE OWNER OR WELL DRILLER ISAND ABANDONED IN PLACE UPON
COMPLETION OF THE WELL AND
REQUIRED TO HAVE THE WELL STAKED BY A NEW WATESERVICE UNE TO THE OUSE
REGISTERED LAND SURVEYOR PRIOR TO
DRILLING TO INSURE WELL IS DRILLED ON NOTE: THE FINAL GRADE WITHIN 10
PROPERTY ANO OUTSIDE OF THE DRAINAGE FEET OF THE WELL IS TO BE SLOPED
EASEMENT. AWAY FROM THE WELL CASINO 1
/ /
SN�
iP• PRWELL } r--k-'"-J
I
1
11
•
\ 1 LKEY BOX
vDOCUMENTED WATER UNE '
LOCATION (PER OWNER)
1
PROPOSED DRAINFIELOS FOR
LOT H -1A, BLK 4; BERNARD S/D
MULTIPLE FOUNDATION.
FRENCH. AND CURTAIN
DRAINS IN THESE LOCATION
(PER OWNER)
DO-
S1E� FRi
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
3701 G TUDOR 110.0. SAE IDI • YDOPMCL r W,01 • /41d[ 001)317.4I77 • FAX NO1)370-714 • 1071t11.110•0770nM. M
PREPARED FOR:
RUSS OLIN
PHONE NUMBER:
227-4943
LEGAL DESCRIPTION:
BERNARD 5/D; BLOCK 4, LOT H1 -B
PACE NUMBER:
2 OF 2
1•.40'
TYPE OF WORK:
DESIGN OF PROPOSED WELL AND WAIVER REQUEST
DATE: REVISED
8/13/2009
(Rev. 01/X1)
Municipality of Anchorage Page /of S
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: 5-W 9510 3 4Z- PID Number. oe0O3Z4Z-C-
Name:
� 0 Y LC. A4 , TJ ons cs
Wastewater System: Lew ❑ Upgrade
Y
Address:
ABSORPTION FIELD
Rua—Phone: No. of Bedrooms:
0 Deep Trench 0 Shallow Trench llred 0 Mound 0 Other
LEGAL DESCRIPTION
Soil Rating:
• . .
7GPD/SqFt
Total Depth from original grade:
2
Lot: Block: Sub/division:
/ ' /�.�,1i7=-.4
Depth to pipe bottom from original grade:
l 5" Ft.
Gravel depth beneath pipe
Ft.
Township:
Range:
Section:
Fill added above original grade:
1..S Z. S—Ft.
Gravel length:
Ft.
WELL: Pry. S. ❑ New ❑ Upgrade
Gravel width:Number
/13 Ft.
of lines:
.3
Distance between lines:
` Ft.
Classification (Private, A.B.C):
Total Dept •
Cased To:
Ft.
Total absorption area:
f#—o SQ. Ft.
Pipe material: ;t'7`rf U—S 133 ¥
f--8 "O
Driller:
• - - •
Static Water Level:
Ft.
Installer:,4‘"msc,41-
haTNI
Date i stalled:
2.."- 30 ,!l -
Yield:
PM
mp Set at:
Ft.
Casing Height Above Ground:
Ft.
TANK
K
SEPARATION DISTANCES
)(Septic 0 Holding
0 S.T.E.P.
To
From
Septic
Tank
Absorption
Field
Litt
Station
Holding
Tank
Public/Private
Sewer Linea
Manufacturer:��'
/-AJ�. / 17/ k
Capacity in gallons: �!
• O
/COO
Well
1 7,177)°
> )4/0 t
N/A.--N/fr-
> xve,
Material: Szr
Number of Compartments:
Watere
SurfacLot
>, ro '
>, SO'
N/,a—
--
LIFT STATION
^(i
Line
N
3%'
_
i7'
/
,4-
//h
t.-- JO'
Size in gallons:
Manufacturer:
Foundation
.
"Pump on" level at:
"P •• " evel
at:
High water alarm at:
Curtain/Pump
Drain
4/4---
N/J.-
4—
/V �fr
N ,N
Mak . •
Elec rical Inspections
performed by:
Remarks: 4ovrcxt-, F/kr3lLtc, 4-4et AlroVi
BENCH
MARK
10P t.r4yGA— OF 5a'n c.. nom_ Fare,—
Location and Description:
T of Ir l
00x. •
s/4-.44 fZ. 2QUrtLiz, b U G FAST PALM -
�iO,J ,ta- OF uND nt ' IJ c, 6?
Assumed Elevation: !ab o
Ft
-1 s s u, P L t.72 Is 6,,,44-C,,Lct-��. 54 -Ni+ 64-4V a L , ,u
ENGINEER'S SEAL
J SiL.(.A4. HOvsx au,4'io'J Is ,v07 i,4sr4c.c,�G.
.{1' .
t,
Inspections by: 1f. Dates:1st st �X 7, 2 $'-.1,/')':2-
performed
2nd 9/L,, 3 C7 t , ,m oo n
on eS^
d:!bl E
Department of Hea nd,Human rvices approval
•.
lH...)e1
„\.a��'
�, , 1 r'Y',;,;
�� 7- /s'- 9B
by: Date: � �,,; fi �,�m
Reviewed and approved
72-013 (Rev. 9/91) MOA 25
Permit No. 5 UJ '19 O36 L
Page
c- of
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: DoT fel 8, g rout. 441 8a12,,J M1,6
•
OMNI. .1015
vcZ
.73
PID No.: OW 3Z1 LS
00
.0 r%
.,
to
r►
ur
tn
IC,
,—��OI
IN
%
O
o
4=�0
4:='i l - L
•
Permit No 5u-) q4 °
Page of
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: 6,1—/43 . to a 46 1ff--" A42-0
4,11
\O
—0V
PIDN0.: •
°60
$1
ok
•
la it, • v1P A
,cir•
404--61
ft
10'
... . ...... •
--.Vo",.•\61\-./e.rAY \V‘v•elf..%*
'2?
w'
........
..... ...... . .
...
662M'
01b
"Al
.c"- • -:.\ '
,.. i
'
,. .
" fi,..,.. , • , _ , , ,
„,lirelf.)f
-',''.,,e_ •,,, PV,A.1,c2,,,.! 1,i, . ,: 0 ''' '''. tr'.
,.,-.,,,70.Y1 ,?,1.: j. i.,',
ar,ne
)" -•• , 4 • .
t.;v''''.72,. ,,,,,,'"",- ,,-. -...7,0. • ;', ,,. '..'; ,,,/ '
/...‘,. 4 .
'a .',•„..' ' ' OP- ' '''I''.' ''' "1....!:'
'''''0=,.''•-..e.,,,..,,....;.^.,
ODUCT 21I SAO snotty 2t,11C401 /1/71IflC.. Gmort Mau 01471 74 Order PHONE MI PEE • • i00 221 11414
ATTAC F- To
October 19, 1995
Municipality of Anchorage
Department of Health and Human Services
Onsite Services Section
P.O. Box 196650
Anchorage, AK 99519-6650
Attention: Jim Williams
RECEIVED
OCT 191995
Municipality of Anchorage
Dept. Health & Human Services
Subject: Lot H1B, Block 4, Bernard Subdivision
Septic System As -Built
Dear Jim:
The owner of Lot H1B, Block 4, Bernard Subdivision recently replaced the
monitor tube on the west end of the absorption bed. The perforations in
the monitor tube now extend only through the drainfield rock in the bed. I
verified the acceptability of the monitor tube by visiting the site on
October 19, 1995. The bed is now in conformance with Municipal
requirements and can be certified.
Please let me know if you have any questions.
Sincerely,
Michael E. Anderson, P.E.
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: oli44c'k4 & C L4' I ov snua S
LEGAL DESCRIPTION: <A// -P-
2-
5-
6-
7-
8-
9-
10
oC-
-
0-
0
c
0 0
0
o
•b .
o '
I'
D
11 -
12 -
13-
14-
15-
16-
17-
18-
19-
20 -
pt;,
bt,ici,ae! E. Anti rsun •
tews NEi'S SEAL)
DATE PERF04IADI
Township, Range, Section:
SLOPE
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
SITE PLAN
N
S
L
/C 0
P
E
Depth to Water Atter
Monitoring? — 7 ' Date /o /f" P`/
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
,/L'i/i/
/r7:/
P, 7S
/2 %'S 3
/ r
/7.,,31
.7 . (a
/J - 35-.., c
,),.,.,-,/
"`
_
0 <:7s—
/ IT , r,
13,7- Lf°-
1'7, Z7
PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER
--�-� TEST RUN BETWEEN
COMMENTS ��' %�-i� t: f / Solk�•1c�D PMOA.
GV rNo 1.0C
L. CAArI--1) In) ECO AIWA
4 r 4 u.CP I G SOL "UMW– rz444 ..
PERFORMED BY: A • 1-101141 I ry/r""� -1 IFY THAT TI -IIS T ST WAS PERFORMED IN
IG19s'
r
3 /l
FT AND FT
f -O
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE.
72-008 (Rev. 4/85)
August 15, 1995
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
563-7155 563-5389 (FAX)
Rr' r'\/ ED
Municipality of Anchorage
Department of Health and Human Services AUG 1 51935
Onsite Services Section Munk ;norage
P.O. Box 196650 Dept. Heu:., ,. , tuman Services
Anchorage, AK 99519-6650
Attention: Jim Williams
Subject: Lot H1 B, Block 4, Bernard Subdivision
Permit No. SW 930085
Dear Jim:
The design of the septic system for the subject lot was originally
completed by Gary Bock of Bock Engineers. His design was based on soils
tests conducted by himself and David Dayton. Mr. Dayton's soil test
indicated poorly graded gravels with a rapid percolation rate. He
therefore recommended a 2' sand filter be placed to slow the percolation
of septic effluent into the surrounding soils. Mr. Bock's percolation tests
indicated soils with slower percolation characteristics, but he chose to
include the filter sand anyway.
The original design was based on an absorption rate of .8 GPD/SF. This is
apparently an error because when a sand filter is placed the design
absorption rate should be .7 GPD/SF. The design, however, was approved
by the Municipality. The system was not constructed within one year of
issuance of the permit and the permit expired.
The owner of the property asked that I renew the permit and extend the
size of the absorption bed to accomodate a four bedroom home. I then
modified the original design extending the bed an additional 10' and
increased the septic tank capacity to 1,250 gallons. All other features of
the original design remained in tact. The Municipality then reissued the
permit for a four bedroom home.
During the construction of the absorption bed we found the underlying
soils to be very similar to those found by David Dayton with percolation
rates under 5 minutes per inch. We then recalculated the size of the bed
Lot H1 B, Block 4, Bernard Subdivision
August 10, 1995
Page Two
required using an application rate of .7 GPD/SF due to the requirement for
the filter sand. The length of the bed was then extended to 50 feet for a
total absorption area of 900 SF. A four bedroom home requires 857 SF of
absorption area with an application rate of .7 GPD/SF. The bed is
therefore acceptable for a four bedroom home.
The excavator on this project, Alaska General Industries, is scheduled to
attend the certification class on Monday, August 14. Once his attendance
is verified he will become a certified installer.
I have enclosed a gradation and certification letter concerning the filter
sand used on this project. It was delivered to the site by Gate Creek Sand
and Gravel and acquired from Quality Sand and Gravel. It appears to
conform to specifications required by A.D.E.C. I have also enclosed a
testhole log performed during the construction of the absorption bed.
Please review the aforementioned information and advise if you have any
questions or comments. I can be reached at 563-7155.
Sincerely,
Michael E. Anderson, P.E.
Attachments
AUG -09-95 WED 13:47 QUALITY4-SAND+AND4-GRAVEL 3737979
MARK HA.NSEN P.E.
Cnnitlhing Engineers Toiling Lnbnrafory
HCO2 BoX 7387, PAI.MF;R, MC 99645 (907) 746.4721 FAX (907) 746.4721
Quality Sand and Gravel
P.Q. Box 1456
Palmer, AK 99645
Fax: 373..7979
Project: 1995 aggregate testing
Subject: Sieve Analysis, Hyer Road
Gentlemen:
May 20, 1995
Project No: 9524
The following is the sieve analysis of the sand sampled on 5/18/95
Sieve % Passing % Required for DEC Septic Filter Sand
Group A • Group B
1 1/2" 100%
1" 99%
3/4" 98%
3/8" 96%
#4 95%
#10 93% 85-100 85-100
#20 84% 60-90
#40 33% 25-50
#60 8% 0-15 -
#100 1% - -
0200 0.3% 0.5 0-5
Coefficient. of Uniformity Cu
Coefficient. of Curvature Cc
2.2
0.99
4 max
1 Max
The sample conforms to group A and B specifications.
If you have any questions, please do not hesitate to call.
Sincerely,
Mark Hansen
P.01
AUG -09-95 WED 13:52 QUALITY-SANDE-ANDfGRAVEL 3737979 P.01
If TO E (0) ur /LA\
% WALTER J. HICKEL, GOVCRNOR
. fAT-SU DISTRICT OFFICE
DEPT. OF ENVIRONMENTAL CONSERVATION
P.O. Box 871064
Wasilla, Alaska 99687
(907) 376-5038
(907) 376-2382 Fax
June 2, 1995
Mr. John Waters
Quality Sand and Gravel
I.O. Box 1456
Palmer, Alaska 99645
RE: Sieve Analysis for Sand Filter Material; Specification Review
Dear Mr. Waters:
This letter is in response to your letter, received in this office by facsimile on May 22, 1995,
which enclosed the results of a sieve analysis. The analysis was done by Mr. Mark Hansen, P.E..
Based upon your letter, the analysis is for sands from your pit, that are to be used for sand filters
for soil absorption systems (SAS).
After review of the required specification for filter sand, issued by the Department and the
results of your sieve analysis, 1 find that the sample of sand meets the requirements of the
Department.
Therefore, the Department hus no objection to the use of this sand as material for SAS. In order
to retain the Department's non -objection, a sieve analysis on a representative sample, taken frorn
your stockpile will need to be submitted to this office for every 1000 cubic yards stockpiled.
A similar submittal will need to be made next year, by May 1, 1996, if you intend to obtain the
Department's non -objection on your sand. This non -objection is for use in sand liners, which are
constructed in the Mat -Su Borough. It is emphasized that this letter of non -objection is for sand
used in wastewater disposal systems, which are less than or equal to 1000 square feet in size.
Systems larger than 1000 square feet may require A separate sieve analysis, every 1000 ecluarc
feet; however, this is the concern of the owner/developer, not the supplier/source of the material.
Thank you for you cooperation with this Department. If you have any questions, please do not
hesitate to contact me.
Sincerely,
Robert A. Fultz
Environmental Specialist
RAF: gp
cc: Mark Hansen, P.E.
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
To) c.0
TAy Toy
LEGAL DESCRIPTION: ter 1-1f8 &Lock. L7
3G-12,4 SU8.
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16 l
17 1ii,�%C ,O.4
DEPTH
(FEET)
j:›T /DL
GP
BO,r0 M oF 140
18
19
20
COMMENTS
lE
'�w
f,
O© `
a
DATE RERFORI`ti)%()r7
niICllGt'+I E. l-",Ild•:P9otl
d:�h) -E
Township, Range, Section:
SLOPE
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
tQD
SITE PLAN
T
N
S
L
0
P
E
Depth to Water Atter
Monitoring? pate:
P
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
yyam�
01
Qfj (fie
/(1.(i
/01•15"
.—
♦� h."
w
--/-1yU
/0t Z-1
3 f 4
ID' LE.
5'
t 314 "
3t/ ,.
+HzJ
/0t L.7
4,/A•,
/0: 3Z..
? %"
318 .1
(mmutesiinch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND J FT
4"i -J A'L. S eft) f Oa- Tr) ?'moi' L'Ti
7)44 ,.0 7)ayTo NJ *3190
PERFORMED BY A . / ARA LA I
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE'
72-008 (Rev. 4/85)
PERCOLATION RATE
1 N -TV Wv cc
4
IFY THAT THI TE SfT WAS PERFORMED IN
g
is" 95
57YLE NO. 46-6P
P.O. BOX 607638 - ORLANDO, FL 32860 • (407) 886-3100
o /o /Ts -
1) / ALS r E•rir -p
w,g2�/t� Lrnl�
(-am- l f-4. i r. .71)
itowetiox
(OT tt c3 �
V.tyy i3
Oal\ 06\ct
STYLE NO. 46-6P
P.O. BOX 607638 - ORLANDO, FL 32860 • (407) 886-3100
_
r •
•mir. _
Municipality of Anchorage Page of
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: sw 95 (0 3 6'7-- PID Number: 04,C34 -
-/2
Name: r
An -WO
Wastewater System:
y Ly'New ❑Upgrade
Address:
_, )(--3Q -1) V kz t\ 0 01_,L_ -Z./ °I.,--\-
ABSORPTION FIELD
Phone:
No. of Bedrooms:
1 (70,
ElDeep Trench ❑ Shallow Trench CiKed 0 Mound 0 Other
LEGAL DESCRIPTION
Soil Rating:
7 GPD/Sq. Ft.
Total Depth from original grade:
- 2
Lot: / Block Sub/division:
/ ,, e ie -l1
Depth to pipe bottom from original grade:
/ 5- Ft.
Gravel depth beneath pipe
' r- Ft.
Township:
1 Range:
l Section:
Fill added above original grade:
S-z.SFt.
Gravel length:
.-C-Z) Ft.
WELL: AvS ❑ New E Upgrade
Gravel width:
/B Ft.
Number of lines:
3
Distance between lines:
G Ft.
Classification (Private, A,B,C):
,-------..---
TotaLBC
Ft.
Cased To:
Ft.
Total absorption area:
90-0 SQ. Ft.
Pipe material: , t Tr -I /J-3 p3 SC
F—,/,' /o
Driller: '
Date Drilled:
Installer:,/[,, f-5�i-
�NOcQTR/€,
Date installed:
a/3YiC-7VF.xe..4-L
?/z_, - 34./314 -
Yield:
eld:
GPM
Pump Set at:
Ft.
Casing Height Above Ground:
Ft.
TANK
SEPARATION DISTANCES
L9'Septic ❑ Holding 0 S.T.E.P.
To
From
Septic
Tank
Absorption
Field
Lift
Station
Holding
Tank
Public/Private
Sewer Lines
Manufacturer:
,/ YU/�-- T�►/k"
Capacity in gallons:
4 Sl%`$
Well
r
>Zirn
/
�?oo
N/_-
/1/.4.----n
> x -a/
Material:
.sr��
./
Number of Com artments:
p
2—
Surfac
Water
>/ra'
>/SO'
/1/4-
/
-.-----'
LIFT STATION //4_
Lot
Line
— 3 //
i
= Z% '
,v4-
/I/
/
JO
Size in gallons:
Manufacturer:
Foundation
"Pump on" level at:
"Pu level at:
High water alarm at:
Curtain
Drain
A/ /
/
N ,Y111.4F-'/V-
-
N,/,# -•
Pump Make & Mod
Electrical Inspections performed by:
Remarks: 7.�_,,7-----, �/.� 4 ;L /'�r
BENCH MARK
41-1," C...- /� 7 /
- A51.a../' ati /L /�4 44.
Location and Description:
/<� 7b/'.
fMet .5Pr�,•• Sr/e-r /S
.e-_.- t -�e-,A S,. ,.../ , C,-./� /
Assumed Elevation:
/,---.Ft
/�
ISS/%. /�/�c ..0 d....-• //I- t_ . /S ,r.3 // / t. /� /1,
-.ENGINEER'S SEAL
Inspections performed by: /f Dates: 1st'/ 7, z 8
`1 %�-1'/t41, f� C t4 ------
2nd ,/y,, 3
Department of Health and Human Services approval
Reviewed and approved by: Date.
-013 (Rev. 9/91) MOA 25
Permit No SW 9 `f'0 34- 2 _
Page of
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: 1-"c r /411; 13i -v CA- 44) Qa1Znf
PID No.: 0/0032-- I2.5—
Permit No.
Page
of
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: LX
g c- E L -S7? -do AP -CI
PID No •
0L00 S
9,1?
17
t‘:
11 cy jef
9.
5'74
;t4i5f
11 If?'
I
L}ij1 -LV A-51,14
PRODUCT 204.1 (510918 Sheets) 205.1 (PaddecO /Nanife,. Inc., Grown, Mass, 01471. To Order PHONE TOLL FREE 1.4007n 4180
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW940362
DESIGN ENGINEER:ANDERSON ENGINEERING
OWNER NAME:JONES JOYCE M
OWNER ADDRESS:PO BOX 771441
EAGLE RIVER, AK 99577
PARCEL ID:06032125
LEGAL DESCRIPTION: BERNARD BLK 4 LT H1B
LOT SIZE: 47792 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
Si
PAGE 1 OF 1
DATE ISSUED: 9/23/94
EXPIRATION DATE: 9/23/95
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3 THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 (24 HOURS)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL
RECEIVED
PROVISIONS:
BY : rti .C,
ISSUED BY:
•
DATE:
DATE:
4�
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, ALASKA 99524
September 23, 1994
Municipality of Anchorage
Department of Heath & Human Services
825 "L" Street
Anchorage, AK 99502-0650
Attention: Robbie Robinson
Subject: Lot HIB, Block 4, Bernard Subdivision
Permit No. SW930085
Dear Robbie:
The permit for the septic system on the subject lot has expired. The
owner wishes to renew the permit and extend the size of the
absorption bed to accomodate a 4 bedroom home. 1 have modified the
site plan to include the additional bed size and have included the
backup calculations.
The gravel soils found on the lot are excellent for an onsite system and
increasing the size of the bed appears to pose no problems. Please
amend this permit to allow placement of a system to accomodate a four
bedroom home.
Sincerely,
Michael E. Anderson, P.E.
SITEPLAN FOR ON-SITE SEPTIC SYSTEM
LEGAL: LOT IF -1B BLOCK 4 STEWART SUBDIVISION PLAT 181-245
NIA 1 J rAid 10'
Sap a.44 -r-7 (70 Elz-orA
P▪ P▪ M
0'
Lot H -1B, Block 4, Bernard Subdivision
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom Home Shallow Bed System
Perc. Rate: 5.7 , Min./Inch 1,250 Gal. Septic Tank
Application Rate: ? .8 GPD/SF 2' Filter Sand
4 Bdrms. X 150 GPD / .8 GPD/SF' = 750 SF
750 SF / 18' Wide = 42' LF of Bed
Therefore: Construct a Shallow Bed System 18' Wide X 42' Long.
Two Feet of Filter Sand Must Be Placed Beneath the Drainfield
Rock.
0
GLrcAt3 4`rT
3, VZ.." 5'��t'ti� hoc ; -To-P
IT
NOTE: Maintain 4' Separation from Bottom of System to
Groundwater.
Grade Area Over Trenches to Drain Away From Field.
BOCK ENGINEERS
SEPTIC SYSTEM DESIGN
LOT H -1B, BL 4 BERNARD SUBD. PLAT #81-245
OWNER: Tom Stoltine
3 BEDROOM: - use 1000 gallon tank
SOILS: - GP with water table at 7 to 8 ft. depth - use sand filter
@ 150 square feet per bedroom.
SEEPAGE AREA: - 3 x 150 / 0.8 = 563 SF.
USE: 18' x 32' bed
41-
......4,W111)
s��
• •• �•� t
aco. •
f _'49TH
r
3ary R.90S� w%
CE 4200 :
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR: c,.j JVIA. (/)J !L(. -A -71.—f)
LEGAL DESCRIPTION: LLThil /3 Lcx/f
e .i44
/ ,7f
Datil R. I7ayt+sMLP,
• MO. 2203-E ,t 4
DATE PERFORMED:
Township, Range, Section:
S'1Na5'
c.
6? 6,-4-yac -
COMMENTS 14/, rt
PERFORMED 8Y: D 2ial v )
SLOPE
WAS GROUND WATER
ENCOUNTERED? Yc'S
IF YES, AT WHAT
DEPTH?
Depth to Water Alter.
Monitoring? 7 =L2
7,
Dale: 8/30/90
S
L
0
P
E
SITE PLAN
N
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
PERCOLATION RATE
TEST RUN BETWEEN
Id
(minutes/inch) PERC HOLE DIAMETER
FT AND FT
izr,r.. IFS
e/S"u7 Ste?' ,,• i g '7z- - Z /" C? /76--c'175/z—
_
7Sl /z -
y CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE. L 3j .? f�1YC/
72-008 (Rev. 4/85)
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG —• PERCOLATION TEST
PERFORMED FOR lO"t' \.
DATE
11�� ` \ 1 -• , f .p, Range, t4 :
LEGAL DESCRIPTION: i ,�,., ownshlp, Range, Section:
DEPTH
(FEET)
2-
3-
4-
5-
6-
7-
9 -
11 —
12-
13-
14-
15-
16-
17-
18-
19-
20 —
. OMMENTS
SLOPE
0
WAS GROUND WATER \/ ..,
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Depth to Water Atter a/
Monitoring? Dale:
s
L
0
P
E
r �: '1( 4_
,r$7'V,'�ENGINEER'
#0,C7..
'
4 • • .r.QTk-1
r,
3ary it ck • ,
CE 4200
.•• -
tL •
PERFORMED:
SITE PLAN
N
7
A
A,
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
8
z
,
0
4 /Z.
3)44
,I -G
?0
1f, /i
17/9
/g
'•PIL_t-»
S
; s1 .b
'AD
1 /4
SIG
1,
, S
4-0
t7 iz.
/
3
•I C
S 0
\ S S✓ek
1 'V
�t 1
Q0
\� •/4)
`"/
I
PERCOLATION RATE
TEST RUN BETWEEN
j,.7)c&mt-rt .1%•,\ R(11
PERFORMED BY Z:1I ��' 1 G.1A N CERTIFY THAT TS TEST WA PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE 4/
72-008 (Rev. 4/85)
(minutes/inch) PERC HOLE DIAMETER
FT AND FT
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:70 t4. 1°O L-1-
LEGAL
1
LEGAL DESCRIPTION:
DEPTH
(FEET)
1-
* '49?!i
r...
d
Gary R � • iv
CE 4200 r�
i
DATE PERFORMED: `I
\ O To ns 'Range,'TectZip
ion:fjL
e-
2-
3-4
4-
5 -
6-
7-
L�� L����
8-
9-
10 -
11 -
12-
13-
14 -
15-
16-
17-
18-
19 -
20 -
;OMMENTS
SLOPE SITE PLAN
WAS GROUND WATER 1 0
ENCOUNTERED? lJ
S
IF YES, AT WHAT L
O
DEPTH? P
Depth to Water Atter __
Monitoring? Date:
N
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
c;1} if 427
1.5 /ice
-;
1)) ', 0
.. U
1 '7 �/ 4•
7/�
1 0 ', t Q
eS
1 4 1 j
---, T-
10'.\$-,
1�a 'J '
{ V/Q
(�
10',
-4b
1,(0) / _
1 1 /i
-7
I D •_�
<Q
1 5/A,
t 1/58
I o' •=1-
(o 0
\rt 5/ 14,
"11(c)
f
PERCOLATION RATE 14-' (minutes/inch) PERC HOLE DIAMETER ''
TEST RUN BETWEEN drFT AND 5 FT
PERFORMED BY: L -)(?) 1 �.3 "F e... CERTIFY THAT THIS TEST WAS� PERFORMED IN
ACCORDANCE WITH ALL STATE ANO MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: -4/ -2.7
f / {,3
72-008 (Rev. 4/85)
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: Lot H-1 B, Block 4, Bernard Subdivision
GENERAL:
1. The scope of this project includes the procurement and
installation of a 1,250 gallon septic tank and the
construction of a shallow seepage bed to serve the proposed
four bedroom home.
2. Construction shall be in accordance with the approved site
plan, design drawings, Municipal Permit with any special
provisions or conditions, and all applicable State and
Municipal Wastewater Disposal Regulations.
3. The Contractor shall be responsible for obtaining all
underground utility locates.
4. Unless specifically agreed otherwise, the property owner
shall be responsible for final grading areas subsequently
depressed from soil settling. Property owner shall also be
responsible for revegetation of affected areas unless
specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must
be certified by the Municipal Department of Health and
Human Services for system installations. Owners installing
their own systems must receive prior approval from D.H.H.S.
before beginning system installation.
SEPTIC TANK INSTALLATION
1. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts
for pumping access.
2. The septic tank shall be sufficiently bedded to prevent
settling or shifting of the tank.
Lot H-1 B, Block 4, Bernard Subdivision
September 24, 1994
Page Two
3. All standpipes on the septic tank shall extend a minimum of
12 inches above final grade.
4. Septic tanks installed without 4' of cover shall have a
minimum of 2" of direct burial insulation.
5. A foundation cleanout shall be installed one to four feet
from the building foundation. Two cleanouts shall be
installed between the tank and the drainfield. The first
cleanout shall be located on undisturbed soil not more than
10' from the tank. The first cleanout shall be to clean
toward the drainfield. The second cleanout shall be to clean
toward the tank.
6. Final grading over the septic tank shall be such that a
positive slope exists away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The seepage bed shall be constructed to the dimensions
shown on the design. The bottom of the bed shall be within
2" of level. The bottom of the bed must be raked before
gravel placement.
2. Distribution piping must be placed level with perforations
down atop a level bed of drainfield rock. Rock should then
be placed over the pipe to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between
the drainfield rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the
locations shown on the design. The portion below ground
must be perforated.
Lot H-1 B, Block 4, Bernard Subdivision
September 24, 1994
Page Three
5. Direct bury insulation must be placed over the distribution
system when less than 3' of backfill depth is available.
Finish grade over the bed must be mounded to prevent
settlement or depressions.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a Municipally approved
septic tank manufacturer.
2. The following pipe materials are approved for use in septic
system installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C.
(perforated and solid), ASTM F810 or H.D.P.E. (perforated, but
not solid) and ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial
polystyrene (Dow Chemical Co. Styrofoam HI or equalL.
4. Septic tank inlets and outlets shall be fitted with
watertight couplings (Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must
be installed between the final drain rock layer and the
native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than
3% passing the #200 seive.
INSPECTIONS:
A minimum of two inspections are required by Municipal
Ordinance. These inspections must be conducted under the
supervision of a professional engineer registered in the State
of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation
of any gravel. A septic tank may be set in place, but may not
be backfilled.
Lot H-1 B, Block 4, Bernard Subdivision
September 24, 1994
Page Four
The second inspection must be conducted after the placement
of the geotextile fabric, gravel, distribution piping,
standpipes, cleanouts and insulation. No backfill should be in
place at the time of inspection.
Tom Fink,
Mayor
Municipality of Anchorage
May 5, 1994
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
Thomas & Arlene Stoelting
PO Box 241368
Anchorage, Alaska 99524 1368
Subject: Lot I11B Block 4 Bernard Subdivision
Permit #SW930085, PID #060-321-25
The subject permit, issued May 5, 1993 by this office for a
single family well and/or on-site wastewater system, has
expired as of May 5, 1994.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as -built inspection report must be sent to this office for
review, approval and documentation. All inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
Sincerely,
n Smi rf , P.
Program Manager
On-site Services
enc: Copy of Permit
cc: Bock Engineering
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON—SITE WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW930085
DESIGN ENGINEER:DUMMY COMPANY
OWNER NAME:STOELTING THOMAS II & ARLENE
OWNER ADDRESS:P.O.BOX 549688
FT. RICH, AK 99505
PARCEL ID:06032125
LEGAL DESCRIPTION: BERNARD BLK 4 LT H1B
LOT SIZE: 47792 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
PAGE 1 OF 1
DATE ISSUED: 5/05/93
EXPIRATION DATE: 5/05/94
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4329 OR 343-4681 AFTER BUSINESS HOURS
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY: { ) r' , / DATE:
ISSUED BY: �;; c i DATE:
1
THOMAS STOELTING, II
PO BOX 5496
FORT RICHARDSON, AK 99505-0496
(907) 561-5982
May 5, 1993
RE: Permit for H1B
TO WHOM IT MAY CONCERN:
I, Thomas Stoelting, II, would like approval to do my own
excavating on the septic system for the property at II1B.
I feel confident in my ability to accomplish this as I have
17 years of experience working heavy equipment through Local
302 Operating Engineers.
Thank you.
Sincerely,
/1/4-'e
Thomas Stoelting, II
id
C.: \'4
If\yet f? ItJ
0
BOCK ENGINEERS
April 27, 1993
John Smith, P.E.
Manager, On -Site Services
Municipality of Anchorage
P.O. Box 196650
Anchorage, AK 99519
Re: Lot H -1B Bernard Subdivision (MOA PLAT #81-245)
SEPTIC SYSTEM NARRATIVE
Dear Mr. Smith:
I have tested and investigated the above lot for installation of a
septic system and offer the following findings regarding its
adequacy to support the proposed system:
The immediate area is served by the private Bernard Water
System rather than individual wells.
The area has large lots and generally good absorption
capacities thus allowing sufficient room for septic sites
and reserve areas.
Immediate neighboring septic systems are all +50'
distant.
Drainage will not be affected. I have set the system
back 100 ft. from the drainage easement on the lot. The
easement does not contain any evidence of being an active
watercourse even during spring runoff.
For any questions, I can be reached at 696-5735.
Very truly yours,
P.O. BOX 874662 WASILLA, AK 99687 PH:(907)696-5735
BOCK ENGINEERS
SITEPLAN FOR ON-SITE SEPTIC SYSTEM
LEGAL: LOT H=1B BLOCK 4 STEWART SUBDIVISION PLAT #81245
�, `
OF ..
a es....a..
off 'F9j1t
r..
to', ",,'
o Gory R. [ o
C.C: 4200
K _I130x
1«., :Box
C\N IA'Tr
V--",
w\\ � i\La,rc-
P.O. BOX 874662 WASILLA, AK 99687 PH:(907)696-5735
BOCK ENGINEERS
SEPTIC SYSTEM DESIGN
LOT H -1B, BL 4 BERNARD SUED. PLAT #81-245
OWNER: Tom Stoltine
3 BEDROOM: - use 1000 gallon tank
SOILS: - GP with water table at 7 to 8 ft. depth- use sand filter
@ 150 square feet per bedroom.
SEEPAGE AREA: - 3 x 150 / 0.8 = 563 SF.
USE: 18' x 32' bed
:-(1 y P. floc,
CE 4200 ^'
S-- 1 c R
FIELD NOTES:
Bottom of bed 4 ft. below natural ground on uphill side
of bed.
See attached specifications next page.
P.O. BOX 874662 WAS:LLLA, AK 99687 PH:(907)696-5735
BOCK ENGINEERS
BED DETAIL FOR ON-SITE SEPTIC SYSTEM
LEGAL: LOT H -1B BLOCK 4 STEWART SUBDIVISION PLAT #81-245
3 yI
z
c)
C)
P.O. BOX 874662 WASILLA, AK 99687 PH:(907)696-5735
BOCK ENGINEERS
SPECIFICATIONS FOR ON --SITE SEPTIC SYSTEM
LEGAL: LOT H -1B BLOCK 4 STEWART SUBDIVISION PLAT #81-245
A. General
1. The septic plan is for a single family residence only.
2. The site plan and design shall be a part of this
specification.
3. All materials and workmanship shall meet the requirements
of the Anchorage Department of Health and the state D.E.C.
4. All soil tests are advisory to the design and are to be
verified or modified in the field by the engineer.
5. All excavations and depths are advisory and are to be
verified or modified in the field to meet Municipality of
Anchorage and state D.E.C. requirements.
6. It is the responsibility of the owner to obtain all
necessary permits and or easements.
7. The excavation is to be exactly in the area shown on the
site plan, any deviation requires engineer approval.
8. It is always recommended that a surveyor locate the
nearest lot line position and the location of any
easements.
B. BED
1. The bed is to follow the natural land contour to maintain
uniform total depth of the bed bottom.
2. The bottom of the bed shall be level, plus or minus 2.0"
3. The total depth of the bed excavation shall not exceed 4
feet at any point.
4. The bed gravel is to be covered with a geotextile filter
fabric material.
5. Soil or a combination of soil and extruded board
insulation to an equivalent depth of 4 feet is to be
placed over the absorption bed.
6. The area over the bed is to be finish graded to prevent
ponding of surface water runoff.
F.O. BOX 874662 WASILLA, AK 99687
PH:(907)696-5735
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOU — PERCOLATION TEST
PERFORMED FUR! %1'i,t (/V it- (-r'VA-1)
64t3"1ZvOnfLcvl3,
LEGAL DESCRIPTION:LQTNf/9 6 Coc e:
2—
z -s'
3-
4-
6-
7 -
8-
10--
11 -
12 --
13-
14-
DEPTH
(FEET)
>r�rY, .S'7ivy
15-
16-
17-
18-
19-
20 -
CSP %/l✓p✓vt
;E'NGINEp'S'' 1t
9;x"11
1k
Dcrvk1 R. Lrory ttlr
tri.% MO. 22(15-E
•cc,
�o . "*"4
DATE PERFORMED:
Township, Flange, Section:
SLOPE
WAS GROUND WATER _
ENCOUNTERED? YG--5
IF YES, AT WI IAT
DEFIB?
E
Depth to Water Aller
Monitoring? _7 s? Date: a4o,//i--)
•
SITE PLAN
N
Reacting
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
PERCOLATION RAI E
(minutes/inch) FERC HOLE DIAMETER
1 EST RUN BETWEEN ET AND FT
COMMENTS J T 1), i5/ /L = /1-,-_i?S>L- _27C-57
7-
f?
PERFORMED BY' 19/¢ r� V/ '/�/ LVA,'I :4-u"� CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT UN DOS DALE. DA1 E:
72-008 (Rev. 4/85)
L z '
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
LEGAL DESCRIPTION:
DEPTH
(FEET)
1 —
2 -
3 -
4 -
5 -
6 -
7 -
8 -
9 -
10 -
11 -
12 -
13
14
15 -
16 -
17
18 -
19
20 -
;OMMENTS
. ,
•
DATE PERFORMED:
•
ToWnship, Range, Section:
)
SLOPE
•
iy
1
WAS GROUND WATER \
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?P
Depth to Water Afterilia/
Monitoring? ) Date. 4
s
L
0
E
SITE PLAN
1111111111111111111
11111111111111111111111111
1111E111111111111111110111
111111111111111.131111111111
1111111M11111111111111111
11111111111111111111111111
11111111111111111111111111111
1111111111111111111111111111
11111111111111111111111111111111111
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
''' /:!...,
1 '
"
1 e 4 '
t
/ ...)..,
1 1
" •
•
../ , /Al-
-A I' l
\
-- •
ii, - _,..
1
i ( )1
)
''
i r
c-,1";1
—/ - .
.
!
\
I
,
I
)
k
PERCOLATION RATE- ' •
(/1
(minutes/inch) PERC HOLE DIAMETER
. -
TEST RUN BETWEEN " FT AND I FT
•
o
PERFORMED BY:
e X 1 (,1, CERTIFY THAT TH S TEST WA(PERFORMED IN
4/
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
e
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
DATE PERFORMED:'
LEGAL DESCRIPTION: 1 j
DEPTH
(FEET)
1 —
2-
3-
4 -
5-
6-
7-
8-
9--
10-
11 -
12-
13-
14
15-
16-
17-
18-
19-
20 -
o nsfftp, Range, Section:` F
SLOPE
SITE PLAN
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
S
L
0
P
Depth to Water Alter
Monitoring? Date.
■■■■■.■■■■
MIIMERIEMEEN
mmom== N■■
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
', .
10
r , ,,,-
I A \ l \
:__x .. ,
r (-)
1'
�'
1
i1
`1 Vii`''
> � `t�;
,
71(1)
10-
PERCOLATION RATE
TEST RUN BETWEEN
(minutes/inch) PERC HOLE DIAMETER
FT AND FT
;OMMENTS
PERFORMED BY'
CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE
72-008 (Rev. 4/85)
Municipality of Anchorage
On -Site Water & Wastewater Program
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
Parcel I.D. 060-321-25
1. GENERAL INFORMATION •
Complete legal description BERNARD; BLOCK 4, LOT H -1B
Location (site address)
Expiration Date: / L79. / 7 - / q
19090 ELNORA LANE *EAGLE RIVER, AK 99577
Current Property owner(s) RUSS OLIN
Mailing address
Real Estate Agent
Day phone 441-5301
19090 ELNORA LANE *EAGLE RIVER, AK 99577
2. TYPE OF DWELLING:
▪ Single Family (wlwo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
4. TYPE OF WATER SUPPLY: ,
Individual Well
Individual Water Storage
Community Class Well
Public Water System
WaiverNariance request for:
n/a
•
n
4
Day phone
CCEP E
In Per AlC23,10.1“.12.1119
SEP 1 © 2014
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
Community On-site
Public Sewer
•
C
Distance: —
Received by:
COSA to be released to the engineer, unless otherwise requested by the engineer.
Date:
COSA Fee $ S2- --
Date
Date of Payment a. I) I)1'1 cJ
030-14 I Lilt
Receipt Number
COSA #
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179
Address
3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, GEG, LtD. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features, The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
6. DSD SIGNATURE
System #1 Approved for 1' bedrooms.
System #2 Approved for bedrooms.
Disapproved.
Conditional approval for,
Date gig lice.
000600444
o°
ss:' 0
CE/ -775 m�p0
'3rofessio(
44444
\ �-0 tOFt (ANC, ??(%
ON SITE ��
�� WATER AND
bedrooms, with the following stipulations d O1
WASTEWATER
PROGRAM
���lJJpp��NISF'�G��O,��
By:
Original Certificate Date: 1 - / / '/ 4"
The 7f9u pal/r" , ' 'bhorage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.
The Municipality of Anchorage is riot responsible for errors or omissions in the professional engineer's work.
7. ATTCHMENTS:
COSA Checklist
Septic System Advisory
Well Flow Advisory
(Ppv 11/R51
Nitrate Advisory
Arsenic Advisory
Other
*BELOW EXISTING GRADEI
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: BERNARD; BLOCK 4, LOT H -1B Parcel ID: 060-321-25
A. WELL DATA
Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) YES
Date completed 6/26/09 Sanitary seal (Y/N) YES Wiresro erl
p p y protected (Y/N) YES
Total depth 280 ft. Cased to 44 ft. Casing height (above ground) 18+ in.
FROM WELL LOG AT INSPECTION
Date of test 6/26/09 8/12/14
Static water level 23 ft. 37 ft
Well production 5 g.p.m. 2.65 g.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 ml. Nitrate 1.32 mg./L. Collected by: GEG. Ltd.
Arsenic: ND ug./L. Date of sample: 8/8/14
*NO FCO — HOWEVER, THERE IS A PRE—TANK CLEANOUT AND
B. SEPTICIHOLDING TANK DATA
OTHER C/O'S LOCATED INSIDE THE HOUSE. (91 y ra
Tank Type/Material SEPTIC/STEEL Date installed 9/27-30/1995
Tank size 1500 gal. Number of Compartments E Cleanouts (YIN) YES
Foundation cleanout (Y/N) *YES Depression over tank (Y/N)NE High water alarm (Y/N)
N/A
Date of pumping 7/28/14 Pumper JR'S PUMPING
C. ABSORPTION FIELD DATA
Date installed 9/27-3o/4s95- Soil rating ..f
Length 50 ft. Width
Total depth *8.17 ft. Eff. absorption area
r ft2/bdrm) 0_7 System type BED
18 ft. Gravel below pipe 0.5 ft.
900 ft2
Monitoring tube **YES
Date of adequacy test 8/12/14 Results (Pass/Fail) PASS
Fluid depth in absorption field before test E in. Water added 684 gal.
Elapsed Time: 115 min. Final fluid depth D in.
Depression over field NO
For 4 bedrooms
New depth 2 in.
Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date —
THERE IS A BELLY IN THE SEWER LINE FROM THE HOUSE TO THE TANK. SEE ATTACHED RECEIPT
FROM MW SEWER & DRAIN.
**THE MONITORING TUBE ON THE EAST SIDE OF THE DRAINFIELD IS NON—FUNCTIONAL.
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N
"Pump on" level at in. "Pump off" level : ' . High water alarm level at in.
Datu Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'+ On adjacent lots 100'+
Absorption field on lot
Public sewer main
*88'+
N/A
On adjacent lots 100'+
Public sewer manhole/cleanout N/A
Sewer /septic service line 25'+ Holding tank N/A
Animal containment areas 50'+ Manure/animal excrete storage areas 100'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main N/A Water service line 10'+ Surface water 1001+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main N/A
Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 0'
Curtain drain 50'+ Wells on adjacent lots 100'+
F. COMMENTS
*WR#090032 Rohl Acis ins.te` the( -c frtvtot- vtt,Ji {vc{i'c LvLt_set/ft systc*-
THERE IS NO MOA DOCUMENTATION REGARDING ABANDONMENT OF OLD WATER SERVICE LINE.
G. ENGINEER'S CERTIFICATION
9 °1 /y
I certify that I have determined through field inspections and i * : q -'S T ..-7* 61
review of Municipal records that the above systems am in
conformance with MOA COSA guidelines in effect on this
date. p....: _ . vAD
SS o
Engineer's Printed Name JEFFREY A. GARNESS Q s, . — 95 t/
g iy� �p4f 9 cla4>
v
dRndProfessio0Gao
40p000�
Date
(Rev. 11/05)
% `
40'1:00° .704:\ . \
1
|s
(lips)
Vis' -
�ct
,N
■
0
Sewer and Drain
Anchorage: (907) 575-9915
17713 N. Juanita Loop • Eagle River, Alaska 99577
INVOICE NO.
CUSTOMER'S #
DATE
NAME g�
ADDRESS
(7C &d orc tri,
CITY, STATE, ZIP
i
/r � A k py 77
DwSCRIPTIQN
CE".
AMt; Lit
ys Ki�3v51 •, -�s *L.c e.
�� -4t
.
,s . tt�
'
1 t , .,. 4 L
t.. c.0 & A
II
e_ LO L r3 oec
C a n ti- e: C- S © A- L.. e._
eff CVL •
fka4.e 5QtyriLe- �
(3s.-ao
..� d
❑ Cash ❑ Check#
❑CC#
CKJ
13C .....--
Authorized Signature (Open Acct. Only)
OPEN ACCOUNTS ONLY
By signing this invoice the above named account agrees to pay this invoice based on the following terms. Payment
receipt of statement. My invoice unpaid 30 days after statement date will be considered delinquent and account
maybe accrued at L5% per month. In the event that payment is not made, all reasonable collection fees, attorneys
collection cots wilt be assessed as permitted bylaw. Returned checks charged a 525.00 fee.
isdue lnhill upon
suspended. Interest
fees, court or other
GARNESS ENGINEERING GROUP, Ltd
=_mss
September 16, 2014
CIVIL & ENVIRONMENTAL ENGINEERS
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
REF: Additional Non -Functional Monitoring Tube in Bed for Bernard; Block 4, Lot 111-B
To whom it may concern:
We have submitted a Certificate of On -Site Systems Package requesting approval from your department. It was noted
in the package that there are two (2) monitoring tubes in the drainfield and one (I) was functional and the other was
non-functional (did not extend down into the effective). During the review process a "comment sheet" was provided
to stating that the non-functional monitoring tube must be functional. GEG appealed this requirement citing MOA
regulation 15.65.060 Subsurface Disposal Fields, E. "General Construction Standards", item 13. It states, "A
subsurface disposal field must have vertical monitoring pipes installed. At least one monitoring pipe with a minimum
diameter of four inches shall be installed in each disposal field if the field is not continuous. The monitor pipe is to be
perforated to allow liquid level measurement to the bottom of the trench excavation. Non -perforated monitor pipe
shall extend from the distribution pipe invert to above ground level." Even though one (1) of the monitoring tubes in
the drainfield is non-functional, the other is functional and meets the above stated regulation. In short, the drainfield
meets the intent of the code and we request approval of the COSA without being required to do any repairs to the
second monitoring tube.
Please contact myself at 337-6179 if you have any questions or concerns regarding this project.
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com