HomeMy WebLinkAboutSUNDI LAKE BLK 2 LT 12 Municipality of Anchorage
Development Services Department
Building Safety Division '.-'~
On-Site Water & Wastewater Program, 4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650 ~'~
www.ci.anchorage.ak.us (907) 343-7904 Page 1 of
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: SW0501 41 PID Number:. 011-131-20
Name:
ERMA MCMILLAN Wastewater System: [] New [] Upgrade
Address:
8056 ENDICO'rT ST. * ANCHORAGE, AK * 99502 ABSORPTION FIELD
Ph°ne:(907) 248-4225 No. cf Bedrooms:
`3 · Deep Trench D Shallow Trench I-I Bed nMound r'lOther
LEGAL DESCRIPTION ,o,, .~.,: ,otc, o.pth ,,~m o.ol.o,
1.2 aPO/Sq. ~12.0 (MAX)
Block: I.~t: Subdivision: Depth to pipe bottom from original grade: Cmvel depth beneath pipe:
2 12 SUNDI LAKE SEE DWG ~ 8.0
Township: Range: Section: fl, added above original grade: Grovel length:
- - - SEE DWG. n. 30
Grovel wldth: Number of lin°a: IDi~t~nce between lin°I:
WELL: [] New [] Upgrade 2.5 ~ 1I -
Clo~iflc~on (Private, A.B.C): . Total Depth.' Cased To: Total abeoq~flon °m~: P~pe material:
PRIVATE 594 r~ 594 n. 480 so. n. D ,3034/ F-810
Ddllec Data Drilled: Static Water Level: In.to,er: Date In~lled~/
ALPINE DRILLING 11/12/03 152 ~ SMALL POTATOES CON. 11/2005
'lleld: Pump Sat At: I C~slng Ha;ght Above Ground:
50 =p. UNKNOWN ~1 2 ~ TANK
SEPARATION DISTANCES ·septic I-i Holding ri S.T.E.P. El 0that
T~To Septic Absorption Uft Holding Pubfic/Prlv~te Manufacturer: Copeclt~ In gallon~:
Tank Field Station Tank S,,or Un,, ANCHORAGE TANK 1 000
Matadal: Number of eompmtment~:
Well 100'+ 100'+ - - 25'+ STEEL 2
Su~oce Wote~ 100'+ ~00'+ - - - LIFT STATION
Lot Line 5'+ 10'+ _ _ _ Size in gallon°: / I~
Foundation 5'+ 1 o'+ -- -- -- 'Pump on' ,,vel · ~at: IHigh wat,r ak~rm et;
I
Curtain Drain NONE KNOWN · Pump Uok~l: jrlec, fl'~al InJpecflon. performed by:.
Remarks: LINE UNDER DRIVEWAY BURIED 10+ FEET BENCH MARK
Location and DeecdpUon:
BOTI'OM OF TANK @ ST1
J*..u,, ~,.,~Uon: 95.71
. z
Inspections performed by: AKWWC, INC. Dates: 2nd~St 9/19/11/200~1/200,3 ~"~":'~'"ii'i /'~/~ ~"" ....
3rd 9/11/200,3 ~)^ '-.,~'~ ~'~,
Development ~ervi.ces Department Approval ~j, '...,~ ~ --=..'
(,,,. R(~viewed and approved 12/01) b.~'-- ! JiL/~ Date: //~/~/ "1~;'~'" ~:'~.~.~ [['" "'~J of_ss'
t
.PERMIT ~/UMBER:
wo o, AS - BUILT
011-131-20
- /
X. WEST 80TH AVENUE
--~ ~ ~N~ D~N~ /BRODIE P.E.
~ B~ .~ ...... s~c ~K
~ / ¥-'.2-'.:~.:..::-- .-~~.~ ~.~
A B
~ ss.o ~o~.o /
m s,.s ~o,.o /
OBL~ ~.o ~o,.s
MT1 87,0 109,0
C02 67,0 101,5
MT2 67,5 101,0
~SI~ B~TER & B~STE~5~TER
5701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK ~9507 · PHONE (q07~7-6179 * F~ (907)5~8-52~6 1 ~ ~ 40~ '
I
PREPPED FOR: PHONE NUMBER: PAGE NUMBER: ~.~ .........
SUNDI ~KE SUBDIVISION; LOT 12, BLOCK 2 4~,~, 'i .... J ..... '~
AS-BUILT DRAWING OF NEW SEPTIC SYSTEM
.PERMIT ~IUIdBER:
~wo~o~, AS- BUILT D lgAWIN G
011-131-20
~FINAL GRADE =
/104.30 (AVG.)
.
gTCO
AK~C, INC. FINAL G~DE =a ~ ~ ~ORIGINAL G~DE =
,[s~ Howl ~2 ~o~.ss (AV~) ~ H ~0.00 ~ H~H ~O~N~
=
-+ RE.lIVE EL~ATION OF BOSOM OF
TEST HOLE = 81.00 (TEST HOLE DRY) DA~:
............. D~WN ~:
~SI~ ~TER & 55,ASTE~5~TER c.o.o. ~:'" 4
................. CONSULTANTS, ~NC.~ .............. s~:
~,o, ~. ,u~o~ .o~. su,,~ ,o,- ~.o..~. ~ ,oso, · ..o.~ <,o~m,~,~o - r~ <,o~m,-~, 1" = 40'
ERMA McMIL~N (907) ~48-4225 ~ Of ~
SUNDI ~KE SUBDIVISION; LOT 12, BLOCK 2 ~"/.... ....."~
PROFILE AS-BUILT DRAWING OF NEW SEPTIC SYSTEM
Rick Mystrom hffn'lA~n~ ~i ~nr~hnr~cl~ ~' II~: ..
Mayor
'ermit Number: #SW 030141 Date of Issue: 5-20-03 Parcel Identification Number[ 011:131:'20'
fate Started: 11-10-03 Date Completed:. 11-12-03 Is well located at approved P~'/fi~it location? [] Yes [] No
·-gal Description: Sundi Lake BIk 2 Lt 12
'roperty Owner Name & Address: Erma McMillian
8056 Endicott Street
Anchora~le, Alaska 99502
Iorehole Data: Depth (ft)
~il Type, Thickness & Water Strata From To
~tick-up 0 2
randy silt ............... 2 178
rilty sandy gravel 178 185
randy gravelly silt H20 185 220
silt 220 265
';lay 265 382
silty sandy gravel H20 382 394
Method of Drilling [] ail, rotary [] cable tool
Casing type: steel
Wall Thickness: .250 inches
Diameter: _6 inches Depth: 394 feet
Liner Type: __
Diameter: ~ inches Depth: feet
Casing stickup above ground: _2 feet
Static water level (from ground level): 132 feet
Pumping level: 147 feet after
_.2 hours pumping 50 gpm
Recovery Rate: 5__0.0 gpm
Method of Testing~i~/r lift:' "': "": :" "7 .... ':"
· . , .. · ..-...,. ';'~'~'C
Well Intake Opening Type:
[] Open End [] Open Hole
[] Screened Start __ feet
[] Perforations Start ~ feet
Stopped ........ feet
Stopped i.:".'.;".i ' :~f:e~t
Grout Type: bentonite granules Volume: /
Depth: Start O feet Stopped .9 feet
Pump: Intake Depth __ feet
Pump size hp Brand Name
Well Disinfected Upon Completion? [~] Yes I"-] No
Method of Disinfection: __
Comments:
Well Driller:
Alpine Drilling & Enterprises
PO Box 110496
Anchorage Alaska 99511
Attention: The well driller shall provide a well 'log to the property owner within 30 days of completion and the property
MUNICIPALITY OF ANCHORAGE
Development Sen/ices Department
On-Site Water & WaStewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchoragel AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Initial
Date Issued: May 20, 2003
Expiration Date: May 19, 2004
!Permit Number: SW030141
Legal Description:.'SUNDI LAKE BLK 2 LT 12
=:Design Engineer: 0041 AK Water & Wastewater Consultan'
Owner Name: Erma McMillian
Owner Address: 8056 Endicott ST.
Anchorage, AK 99502-
Parcel ID: 011-131-20
Site Address: 005022 80TH AVE W Lot Size: 41334 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
[] Disposal Field r~ Septic Tank E~] Holding Tank ~-] Privy
Private Well
[--] Water Storage
All construction must be in accordance with:
The attached approved design.
All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
The engineer must notify DSD at least 2 hours prior t° each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
.Received By:
Issued By:
Date: ~.=__~__~~,~
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 01 1-131-20
Permit Number S~D~O 14/
Properly owner(s)
Mailing address (1)
Mailing address (2)
Legal description (Lot, Block & Sub'd.)
Legal description (Section, Township & Range)
ERMA McMILLIAN
'8056 ENDICOTT STREET
Lot Size ~ I~_'~ "~4.[
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
* ANCHORAGE, AK
LOT 12. BLOCK
N/^
Acre~
2: SUNDI
Day phone 248-4225
Zip Code 99502
LAKE SUI~DIVI$10N
Number of Bedrooms
Well Only
Water Storage
[~ Jacuzzi [~
E] water Softening unit r-]
I certify that the 'above information is correct. I further certify that this application is being made for a
Single Family Dwelling ahd is in accordance with applicable Municipal codes.
ALASKA WATER &: WASTE'WATER CONSULTANTS, INC.
Permit Fees: ;~
Date of Payment:
Receipt Number:.
Waiver Fees;
Date of Payment:
Receipt Number:
ALASKA WATER & WASTEWATER
August 14, 2003
Municipality of Anchorage
Development Service Department
Building Safety Division
On-Site Water & Wastewater Program
P.O. Box 196650
Anchorage, Alaska 99519-6650
REVISED DESIGN: SW030141
Reft Proposed Well and Septic System for Lot 12, Block 2, Sundi Lake Subdivision
To whom it may concem:
A permit was issued on 5/20/2003. At the time of construction unsuitable soil conditions were
encountered. A new test hole was excavated and better soils were found. The drainfield will be
designed around the 30 foot radius of this test hole. We are proposing that a new 1000 gallon
septic tank and deep trench type drainfield be installed. Comments regarding the design, are
summarized as follows:
1. SOILS: See the attached log which shows the soil classifications, groundwater monitoring,
and the percolation test results. It is our opinion that due to the overall appearance of the soils, an
application rate of 1.0 gallons/day/fie should be used.
2. TRENCH DESIGN:
a. Percolation Rate: 2.5 minutes/inch
b. Proposed Application Rate: 1.0 gallons/day/ti2
c. NumberofBedrooms: 3
d. Design Flow: 450 gallons per day
e. Minimum Absorption Area: 450 fl2
f. Total Depth: 12 feet (max.)
g. Effective Depth: 8 feet
h. Width: 2.5 feet
i. Reduction Factor: N/A
j. Minimum Length: 30 feet long
k. Effective absorption area = 480 ft2
3. SURFACE WATERS: There is no surface water within 100+ feet from the proposed septic
system. In short there are no concerns.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.eom
4. TOPOGRAPHY: As can be seen on the attached topography site plan, the average
topography in the area of the proposed drainfield is a 10-15 percent slope running approximately
southwest to northeast. In short, there are no slope concerns.
I am unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact us at 337-6179. Thank you for your
assistance.
· ere , ~I~.E.,
M.S.
NOTE: Attached is a site plan drawing, a design draw#tg,, a soils log, and a 7page constntction
specification letter which are all part of the design package for this septic system.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com
-'"'"--T"-, ~ IREVISED DESIGNI
I i / ' '" x ~"'""""~
'v/ ~ .~ 'x I~ ~ ~. x · ~ ~. ~m ~ ~ ---~ ...... ~---
I -S~C ~ -' ~C ~ ....
..... 22-2~E~ /..~7~,~. ..'
I~ ..... x~/.~.-' -- 'i~'¢ .o~ ~m / WEST 80TH AVENUE
~ ....... F~UF~ ~11~ ~1~ .... ~ ..... 4 ..... ~-- ................
%_ (S~ D~IGN PAGE 2 OF 2)~ ~ INC. ~ / %. ~MIC~ BRODIE P.~
6¢? / i X ..-- .... --..
.~1%%~ x ~;~ '~.~ %, /~ SUND' ~E SUBDMSlONX
I
~D ~e S/D f2; I x r .......... ~ ................ ¢ ..... ~ ,.~ k. ~
LOT 2:, .~CK
/~
~o~ ~o. eLOCOn.
.,,' __,~, , ,,
i ~ ~ I~ L '' ........ ~ .....................
I~T l~, ~CK 1, ] --x Ill ............ ~ / /
~lx/ -- .... ~i -,FmF ................................. Z / /
tOT 17 ~CK 1 ' z~ I '~ ' ~T ~ BL~K 2, ~T BB$CK 2, ~ / I
~ '-, '
SUNDI ~K~ SUBDIVISION; LOT 12, BLOCK 2, ~,,~" · .'""~
,,.. ~ ....... ~'
~E OF WORK: ~[~,~
SITE P~N FOR PROPOSED WELL LOCATION AND SEPTIC SYSTEM ~ ~:~-
t
I I REVISED DESIGNI
] C-~SEPTIC ~ NOTE: THE CONTRACTOR SHALL HAVE THE NORTH LO~
AR..~_~ ~ UNE AND ALL WELL RADII FLAGGED BY A REGISTERED
! ~ ~ -- -- I_AND SURVEYOR PRIOR TO CONSTRUCTION
I
\ WEST 80TH AVENUE
FIEI...B VERIFY % AKV¢#C. ~NC.
INSTALL DOUBLE
,~ SEPARATION TO ALI ,. CLEANOUTS ~
~ SEPTICS PRIOR TO ~V~ \ \ / ~ALTE:RNATE S~E
. C.N. LO N MICHAEL B
oPosED ..oPosED lOOO \
PRwELL~ SEPTIC TANK % X\, / / _/'ITEsT HOLE ,5
~, / FOUNDATION \ /N~ /~ ! Ak'WWC INC
't} ~ CLE~Om% % :\ c~ /\~ / ~ ~.;h '
~ ~ .:, .~ ,-..%::.,,;..., .-..,., .-_; .:
ZPROPOSED DRNNFIELD, EX~
TRENCH THAT IS 12 FEET DEEP
MAXIMUM BY 2.5 FEEt WIDE BY ,30
FEET LONO. ADD 8 FEET OF
CLEAN, WASHED SEWER DRNNROCK.
C SEP C
/'" ,-. s/~/2oos
~:: , ',%
DRAWN BY.' , ..
c.,,.o.
~-~ ..... CONSULTANTS. INC., .......... 1" = 40' ..... ~ ......... :'"'~
6qOI DEB~RR ROAD. SUITE 2~ · ANCHORAGE. AK qqSO~- ° PHONE (q0~)557-617¢ ° FAX (qO?)5.~8-5Z&6
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
ERMA McMILUAN 24B-4225 2 OF 2 ¢~.~ '..y~ff ~y/, .'C~sT"'~
SUNDI LAKE SUBDIVISION; LOT 12, BLOCK 2,
1YPE OF WORK:
DESIGN FOR PROPOSED WELL LOCATION AND SEPTIC SYSTEM
ALASI~ WATF-R & WASTEWATER ~,r,: '..:~!
...... ---- CONSULTANTS, INC.,~ .... . ..............
LEG~ DESCRIPTION: SUNDI ~E SUBD~SION; LOT 12. BLOCK 2 ] ~-~
PERFOR~ED FOR: ER~ M~MI~N DATE: 1/~/2002 qO~'" I-7~ '""
~;~'",l.~ ........ "¢~
(PAGE ~ 0F 2) 4 e
~EPTH ~
--~ ITEST HOLE
(feeO ~ ORGANICS
~ 6P~ HL ~ ~ ~
~ GH ~ CL WEST 80TH AVENUE
GO OL ~--~
MIC~L BRODIE -
~c.~.c. ~ /
DEPTH TO DATE ~c~ aROSE ~ .~C~ aROSE
GROUNDWATER
P.~ ~ HO~ ¢2 P.B ~ HOLE ¢1~
8~:] DRY 11/7/2002 / SU,D, ~E SUaDMS,O,
~ LOT 11. BLOCK 2.
~'~" 1/14/2002 ~c I .o~mu~
I.~re. DRY ~ I
~','g~ , I
I'~ ~ '
,
~'~" READING!
I'~', CLOCK NET TIME WATER LEVEL NET DROP
"" TIME (MINUTES) READING (INCHES)
~;~' 1/9/2002 1 11:10 - 6" -
2 11:20 10 3"
4 11:30 10 3 1/4" 2
F~;,2, s ~1:~0 10 ~ ~/2" 2 ~/2"
· ~ I,~ ~ 11:40 - 6" -
I'~~', 8 11:50 10 ~ 3/4" 2 1/4"
I&, ¢~' 9 11:50 - 6" -
,~ ~'~'~' 10 12:00 10 4" 2"
~:~': 11 12:00 - 6" -
~n~'¢' 12 12:10 10 4" 2"
""[" PERCOLATION RATE *5.0 (HIN./INCH) PERC. HOLE DIA. 6 (INCHES)
1~ TEST RUN BETWEEN 9.5 FT. AND 10.0 FT.
20~ A FOUR HOUR PRESOAK WAS PERFORHED: ~ YES ~ NO
SOILS LOGGED BY: CALEB GA~ PERCOLATION TEST PERFORHED BY: CALEB GA~
COHHENTS: *RECOMMEND USING A 0.8 APPLICATION ~TE FOR THE SP SOILS.
PERFORMED BY A.W.W.C., INC, I, dEFFR~ A. GARNESS, CERTI~ THAT THIS WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
DEPTH TO DATE
GROUNDWATER
DRY 1/7/2002
DRY 1/14/2002
~.A$I(A WATER & '~VASTEWATER
,=,..~ = CONSULTANTS, INC.-
.,o,.~,,~.su~aa.~o~.~e....~,n(-,)~,-.,,e'r~(.o,)3~4a~'~.'-.-..... ~jSOiL LO0 - PERCOLATION TESTJ
LEGAL
DESCRIPTION:
PERFORMED FOR: ERMA McMI~ DATE: 1/7/2002 ~h~e~ "'..[ ......... "¢~
DEPTH 2 OF 2)
'~ro f ess~O~
SOIL O~SSIFICATIONS
~,GP ~ ML
3--I ~ '~lgM CL
4-- ~ GC OL
~ SW I MH
0 ~' "SP ~ CH
5-- ~ SM OH SEE SITE P~N
sc (PAGE ~ OF 2)
7-- ~ DEPTH TO
GROUNDWATER DATE ,
~o-- O
11 ~ DATE READING CLOCK NET TINE WATER LEVEL NET DROP
-- ~ TIME (MINUTES) READING (INCHES)
~2- ~ ~/B/2003 ~ 4:50 - 6- _
~ 2 5:20 30 5 7/8" 1/8"'
13~~ 3 5:20 - 6" -
4 5:50 30 5 7/8" 1/8"
14~ ~. 5 5:50 - 6- -
~ ~ 6 6:20 30 5 7/8" 1/8"
lg- 0
16~
~7--
18--i
PERCOLATION RATE 120+ (HIN./INCH) PERC. HOLE DIA. 6 (INCHES)
19~
TEST RUN BETWEEN 6.5 FT. AND 7.0 FT.
20 A FOUR HOUR PRESOAK WAS PERFORHED: ~ YES ~ NO
SOILS LOGGED BY: CA~B GALL PERCOLATION TEST PERFORHED BY: ~CH GALL
COHHENTS:
PERFORMED BY AK~C, INC. I, JEFFR~ A. GARNESS, CERTI~ THAT THIS ~S P~RFORMED IN ACCORDANCE
WffH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
DEPTH TO
GROUNDWATER DATE
ALASKA WATER & WASTEWATER 9 r! '""
........... CONSULTANTS, INC., ......
agO1 DEBARR ROag, SUITE 2B ' ANCHORAG~iSOiL LOG- ~ ""~ ' ..o.~-PERCOLATiON(gO7~7-617g. F~TESTj(~2. · ~,~
LEG~ DESCRIP~ON: SUNDI ~E SUBD~SION: LOT 12, BLOCK 2
PERFORMED FOR: ER~ McMI~ DA~: 7/28/2003 vOh~ "" ) C~- 1953 .-"~-~
f TEST HOLE ~2
~ .... ~ GW ..... ORG
"' ~'"~ GP HL ~
GH CL WE~ 80~ AVENUE
GC OL -
~SW HH --C,,NC'
'~ ~' SP CH i~, HO~ ,2~~ . ,.
S~
'~' HO~ ~1~
7 DEPTH TO DATE MIC~L BRODIE
GROUNDWATER
P.E. ~ ~o~ ~2~ P.~
8~IH: DRY 7/28/2003
DRY ~/5/200~ ~o
11 ~[~II DATE READING CLOCK NET TIME WATER LEVEL NET DROP
J TIME (MINUTES) READING (INCHES)
12 7/29/2005 1 8:0~ - 6- -
2 8:13 10 1" .5"
13~ltl: ~ 8:15 - 6- -
4 8:25 10 1" 5"
14~]~: 5 8:25 - 6- -
6 8:33 10 1
15 ~: 7 8:34 - 6- _
16~' 8 '8:44 10 2" 4"
[ 9 8:44 - 6- _
17~1~[, 10 8:54 10 2' 4"
11 8:55 - 6- _
18~ 12 9:05 10 2" 4"
I-'-
PERCOLATION RATE 2.5 (HIN./INCH) PERC. HOLE DIA. 6 (INCHES)
19~~ TEST RUN BETWEEN 8.0 FT. AND 8.5 FT.
20~ A FOUR HOUR PRESOAK WAS PERFORHED: ~ YES ~ NO
SOILS LOGGED BY: SU~N O~ALT PERCOLATION TEST PERFORHED BY: SU~N OSWALT
COHHENTS:
PERFORMED BY A.W.W.C., INC. I, JEFFR~ A. GARNESS, CER~ THAT THIS WAS_ --_P~RFORMED IN ACCORDANCE
WI~ A~ ~ATE AND MUNICIPAL GUIDEUNES IN EFFECT ON THIS DATE:
DEPTH TO DATE
GROUNDWATER
DRY 7/28/2003
DRY 8/5/2003
Rick Mystrom,
Mayor
Municipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519~6650
343-4744
November 14, i994
Ms.. Patricia Randlett
833 W. 22nd Avenue
Anchorage, AK 99503
Subject: Lot #12 Block #2 Sundi Lake
Permit #SW930273, Parcel ID #011-131-20
Dear Ms.. Randlett:
The subject permit, issued August 10, 1993 by this office for a single family well and/or on-site
wastewater system, has expired as of August 10, 1994.
A new permit must be obtained from this office for a well and/or on-site wastewater system NOT
installed by the expiration date.
If you have drilled the well, a well log must be sent to this office for documentation of the
installation and to close the permit.
If the on-site wastewater system has been completed and a licensed Professional Engineer has
inspected the installation of the on-site wastewater system, the original as-built inspection report
must be sent to this office for review, approval and documentation. All inspection reports must
be submitted within 30 days of consu:uction completion.
When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00
for a well permit and $440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
Sincerely,
James Cross, P.E.
Program Manager
On-Site Services
JC/kb
cc: Michael Brodie, P.E.
PAGE
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW930273
DESIGN ENGINEER:MICHAEL BRODIE, P.
OWNER NAME:PATRICIA RANDLETT
OWNER ADDRESS:833 W. 22ND AVE.
ANCHORAGE, AK 99503
DATE ISSUED: 8/10/93
E. EXPIRATION DATE:
PARCEL ID:01113120
LEGAL DESCRIPTION: SUNDI LAKE BLK 2 LT 12
1 OF
8/10/94
1
LOT SIZE: 40074 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72} AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4329 OR 343-4681 AFTER BUSINESS HOURS
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
'TEST HOLE #3 SHALL BE EXCAVATED TO A TOTAL DEPTH OF 18 FEET
TO INSURE NO BEDROCK IS PRESENT PRIOR TO THE INSTALLATION
OF THIS SYSTEM. , // ~ ~
RECEIVED BY: /~ .
August 7, 1993
RECEIVED
AUG 9 1993
tV~un[cjpalit¥ of Anchorage
Dept. HeaJth & Human Services
Mr. James Cross
Municipality of Anchorage
Department of Health and Human Services
900 L Street
Anchorage, Alaska 99502
Subject:
Lot 12, Block 2, Sundi Lake Subdivision
Well/Septic Permit
Dear Mr. Cross:
Enclosed yon will find the proposed on-site sewer design and well location for Lot 12, Block 2, Stmdi
Lake Subdivision. The on-site sewer design has been revised to account for the redi~ction factor needed
when dosignln$ a shallow trench system Please review and approve the enclosed design and issne the
well and sewer permits.
I spoke with you on Thnrsday, 8/5/93, by telephone regarding the maximum on-site sewer system depth.
The test hole locations were excavated to a depth of 16 feet which will determines the maximum depth
of the system to be i0 feet below grade. The enclosed design has located the bottom of the system at 12
feet below grade. In our conversation you stated that the Department of Health and Human Services
would conditionally issue the well and septic permits with the stipulation that the test holes be excavated
to a depth 6 feet below the bottom of the systen~ In the case of this on-site sewer system it would mean
excavating to a depth of 18 feet below finish grade.
If you have any questions concerning the information contained in this letter, please contact me. (562-
2000)
Sincerely,
Michael Brodie, P.E.
Probable Impact Narrative
Legal Description: Lot 12, Block 2, Stmdi Lake Subdivision
Well Impacts
The 100 foot radius will arc into Lot 11 approximately 12 feet at the deepest
penetration point. This should have minimal impact as Lot 11 has been previously
developed with a septic and well sites.
Subsurface Disposal System Imoacts
Lots 3, 4, and 5 of Sand Lake Subdivision, to the north of Lot 12, will not be able to
place a well within 20 feet of the southern property line. This does not appear to be a
significant impact as Lots 4 and 5 have wells located on the northern portion.
The placement of the on-site wastewater disposal system on Lot 12 does not render any
of the adjacent parcels undevelopable.
2.
O0'Og
'k.
O0
o \n o_
TA : t'~q) ~,~b ('~/ j~oe,oo~). ~ ?5---O~.rz
LOT 12, BLOCK ,~, SUNDI LAKE SUBDIVISION
~ 7
7~ ~
LOT 12, BLOCK 2, SUNDI LAKE SUBDIVISION
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L' Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
LEGAL DESCRIPTION:
1
2
3
4-
5
6
7
8
9.
11
12
14.
15-
16
17
18
19-
20-
Township, Range, Section:
WAS GROUND WATER
ENCOUNTERED?
IF YES. AT WHAT
DEPTH?
Oeplh Io Waler After
°'*:~ ~ MonilorJng?
Reading
SLOPE SITE PLAN
Net Depth to Net
Time Water Drop
PERCOLATION RATE __ (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND FT
COMMENTS '-T~LH <~ L~ ~A-~ ,.5 ~3 ~.7~ ~ ~o~ ~ ~ ~o
PERFORMED BY; /~i~ t~:>~o 0,~ ~ I CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 7/~- ~/q ~
72-008 trey. 4/85)
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L' Street. Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED EOR: ~t I-'~-~ I C//~- ~,¢,~E~ ¢.-~z~JT'"'~
LEGAL DESCRIPTION: Zo.'rlZ , ~_~ Z
Township, Range, Section:
3
4
5
6-
7
8
9
10
11
12
13
14
15
16-
17-
18
19
20
COMMENTS
SLOPE
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Monil0ring? ~'~
Reading I Date Gross
z
PERCOLATION RATE
TEST RUN BETWEEN
SITE PLAN
I Net
Net Lt~, t~~ Depth to
Time Water Drop
(rnmutes/~nch) PERC HOLE DIAMETER ~ /t
FTAND . ~' ~ FT
CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE; -~-- '~ ''~ ~ ~ ~
PERFORMED FOR:
Municipalily of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L' Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION:
Township, Range, Section:
2
3
4
5
6
7-
~0
17
~8
20
WASGROUNDWATER
ENCOUNTERED?
SLOPE
COMMENTS
SITE PLAN
s
tF YES, AT WHAT /~ L
DEPTH? ~.~,.. ~0
Oeplh to Water After '?/Z /
Adoflitoring? P-~,~'~'°/,'T'~Oale: ~ ~T.~
Time Water Drop
1
PERCOLATION RATE ~'/ (m~nutes/,nch) PERC HOLE DIAMETER
TEST RUN BETWEEN 7'~' FTAND g'~' FT
PERFORMED BY: J~ II(~'~ ~;;~.~'~ ~.~_
I CERT'FY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THiS DATE. DATE:
72-008 {Rev. 4/~1
MUNICIPALITY OF ANCHORAGF
s
Development Services Department phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 011-131-20
Legal description SUNDI LAKE BLK 2 LT 12
Site address 8008 SUNDI WAY Anchorage AK
Current property owner(s) ELDER &MACMILLAN
Expiration Date:
X The On -site system(s) is/are approved for 3 bedrooms
Conditional approval for
Comments or advisories:
9/9/2025
bedrooms, with the following stipulations:
Original Certificate Date:
10/16/2024
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist
Absorption Field Advisory
Tank Age Advisory
Other
X Well Flow Advisory
Nitrate Advisory
x Arsenic Advisory
x
COSA Approval June 2022
R11
MUNICIPALITY OF
Development Services Department
On -Site Water & Wastewater Section
Phone: 907-343-7904
Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcell.D. 011-131-20
Complete legal description Sundi Lake Block 2 Lot 12
Location (site address) 8008 Sundi Way, Anchorage, AK 99502
Current property owner(s) Sean Elder & Erma MacMillan Day phone (907)204-8783
2. ON -SITE SYSTEMS SIZED FOR BEDROOMS
3. TYPE OF WATER SUPPLY: F0_1 Private Well R Private Well serving 2 dwelling units
R Private Well serving 3+ dwelling units R Community Well or Public
F-1 Water Storage
4. TYPE OF WASTEWATER DISPOSAL: X Private Septic n Private Septic serving 2 dwelling units
El Holding Tank F-1 Community Septic or Public Sewer
5. SEPTIC TANK: RN Steel E] Plastic F] Concrete Fj Fiberglass
Age 21 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: R AWWTS E] Bed RN Deep Trench E] Wide Trench R Seepage Pit
Waiver request for:
Expedited review requested: R
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On -site staff
to verify the accuracy of the information provided.
COSA Fee$ Waiver Fee $
Date of Payment Aa; f_z_
COSA # 0sG 2 q) 37
Date of Payment
Waiver #
COSA Application —June 2022
56.5
Forge Engineering
10/11/24 A+
N/A N/A
N/A
Benjamin Schiller, P.E.
(907) 522-7773
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT '�`'� 907-343-7904
On -site Water and Wastewater Section Fax: 343-7997
www.muni.org/onsite
Septic Tank Advisory
Certificate of On -Site Systems Approval # OSC241371
Subdivision: SUNDI LAKE Block:2, Lot: 12
The septic tank for this property is 21 years old. The average life of an asphalt
coated steel septic tank is 20 years. Typical replacement costs are $15,000 or more,
not including engineering, surveying, MOA permitting fees or site restoration.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.
This is an example of what the metal of a 30 year old steel tank MAY look like.
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT i ;\) � 907-343-7904
On -Site water and wastewater Section/ Fax: 343-7997
www.muni.org/onsite
Arsenic Advisory
Certificate of On -Site Systems Approval # OSC241371
Subdivision: SUNDI LAKE, Block: 2, Lot: 12
A water sample revealed an arsenic concentration of 56.5 micrograms per liter
(ug/L). The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. information on arsenic is available from the On -Site Water and
Wastewater Program website (www.muni.org/onsite) or at 343-7904.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.