Loading...
HomeMy WebLinkAboutSUN VALLEY HEIGHTS BLK 1 LT 9  MUNICIPALITY OF ANCttORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONIVIENTAL ENGINEERING DIVISION 825 L Street- Anchora§e, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT o,~ 7- {.~ *~)6/ []UPGRADE 7 LOCATION _ NO, OF BEDROOMS DISTANCE TO: I Well I Absorption area Dweging Material No. of compartments Width Liquid depth LB ty in gallons IF HOMEMADE: Inside length DISTANCE TO: Manufactul Dwelling PERMIT NO. No. of lines Length of ea ]ie Top of tile to finish grade Length Width Foundation Nearest J,(~ t~ I~.~ Total lengt~_f Trench width Material beneath tile Depth Distan~etween lin Total effective area PERMIT NO. Type of crib Crib diameter Crib depth Total effective absorption area Well Building foundation Nearest lot llne DISTANCE TO: Depth Driller Distance to lot line PERMIT NO. DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER SOIL TEST F~NTING INSTALLER REMARKS DATE LEGAL MUNICIPALITY OF ANCHORAGE~ Department ¢ Health and Environmenta. ~rotection ~ 825 ~ Street, Anchorage, AK. .3501 264-4720 O. ¢~%~ * * * HANDWRITTEN PERMIT * * *'*~'.~>-L_% ~O~' ' ~AND~OR ON-SITE SEWER PERMIT UL~_~J~~ Permit Location: Phone Nu~er: _{-g~ 'Y'--S' Legal Description: ~ [/~_~ ~ / ~ Lot Size: ' Type of Soil ~sorption System Is: /- Trench: ~/ Drainfield: Seepage Bedl Holding Tank: Max~um N~ber of Bedrooms: .~ ~ Soil Rating(sq.ft/br) / The Required Size of the Soil ~sorption System Is: ~T, /~ ~aaGTH ,~ GRAWL m~TH ~ The length 'dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minim~ depth of gravel between the outfall pipe and the bottom of the excavation(in feet). "" R~U~Ra~ SaPT~C<HOL~aS) TANK S~Za =~I~ALLONS "* Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. ~ ~ * TWO(2) INSPECTIONS ARE REQUIRED ~ ~ Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31~ 1 9 $ 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site t~ resideng~e is remodeled to Signe~l: ~ ' ,~ /l/~/~' ~p~. ~C~'~t - SWP/024 (1/81) as sewer system may require enlargement if include more that ~bedrooms.~ ~ssued by: Date: GREA'"'""? ANCHORAGE AREA BOR'C"' $H "-~j 3500 Tudor Road Anchorage, Alaska 99507 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME I'/C< ..... U/.'//i,'ll, D MAILING ADDRESS_ ~`' /''' /i,.?' ,~--~ ' s PHONE LOCAT ON___~'~-/'t/'t?'",'//;. ~,/. LEGAL DESCRIPTION ~,1(' ~';LL_ /~/( / . q~.l,,t,.' ,,'//~/[~ SEPTIC TANK: DISTANCE ~ , , NUMBER OF FROM WELL(I/~II/??I2'U, MANUFACTURER~/~/ /~' .MATERIAL ~J/ /I 1~:~,~ ~ COMPARTMENTS INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH ·LIQUID CAPACITY /~,(~'(.:' __GALLONS. SEEPAGE PIT: NUMBER OF PITS_ / . DIAMETER_ OR WIDTH · j~/i,,i, , LINING MA'I-ERIAL,~,~ CR B S ZE: DIAMETER_Z/ BUILDING FOUNDATION :~:) NEAREST LOT LINE -~ ADDITIONAL ABSORPTION LENGTH~, , DEPTFI DE PTH _, ~L~z .D ISTANC E FROM: TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) __,,~'~'J SQ. FT. WELL: TYPE BUILDING FOUNDATION CONSTRUCTIONS; z',~ Z,~ ,/( //~:,'),'DEPTI4 / NEAREST NEAREST SEPTIC LOT LINE SEWER LINE TANK CESSPOOL __ , OTHER SOURCES APPROVED____ DISAPPROVED __ REMARKS DISTANCE FROM: SEEPAGE SYSTEM DISTANCES: INSTALLED BY: '~"'? /'~'~ ~IPE MATERIAL: ~ LOT SLOPE: ~ REMARKS: }["¢'/ //(, /i / DIAGRAM OF SYSTEM E EFARII1Ei'JT OF HEALTH FIND EN',, IF..~NHENIFIL. PROTEC:TIOF~ ,. ~.,.10 E. TUDOR RD.., FINC:HORFIGE, FIK. 9950? PEFINIT NO, ( .... F PL .1.' CFINT LOCFIT I ON LEGFIL GEOROE L.~ B:I. SUN '¢FILL, EY SRFI BOX g72i',1 LEi]' SIZE 4.:1.,26:5 SO!LIRRE FEET T'¢PE OF' SOIL. RBSOFIBTION SYSI'EH IS: TRENCH f'IFIXIMUi'4 i'-,ILMBER OF BEDROOMS =: 4- SOIL RRTINO (SQ FT/BR>= tt0 I'HE F.EELIZI;.ED _IZE OF 1"HE SOIL RBSORF'TIOI'.,I S"r=,TEi'I IS: :1.0 THE L, ENf3TH DIMENSION IS THE LENGTH (IN FEET) O1-':' THE I.'RENCH OR DRFIINFIELD. THE DEF"rH OF FI TRENCH OR PIT IS THE DISTFINCE BE]'I.4b~EN THE E;URFFIC:E OF THE AROUND FIN[.., THE BOTTOF"I OF THE EXCRVFITION ,::IF,I FEET>, THEFIE IS NO SET 14IDTH FOR TFIENCHES. THE GFIRVEL DEPTH IS I"HE i',IlNIi'4UH DEPTH OF GRRVEL BETP.IEEN I.'HE OUTFRLL PIF'E FIND I'HE BOTTOr,1 OF THE: EXCFIVFIT~ON (IN FEET>. ~q~" F-_= [=..., LII 21.' ~:El{t, SEP'I- :[ C: 1-RNI<: ~_; I: ZEE= "'l...2~S E.l E, FIE, k,F ILL. If,,IG OF FINer' SYSTEM !4II'HOLIT FINFIL INSPECTION FIN[.., FIPPRDVRL E:'¢ THIS L"EPFIRTHENT [41LL BE ..,I..IBJ'Et.. f "['O PROSECIJT ! 0['4. MINIMUM DISTFINCE BETWEEN R NELL FIND RN"r' ON-SITE SE.t4ROE 1O, ISPOSRL SYSTEM IS ±00 FEEl'' FOR FI PFIIVRTE WELL. OR 200 FEET FOR FI PUBLIC NELL, SF'ECIFIC:RTIONS RN[> CONST'RUCTION D:I[FIGFIFIMS fiRE RVRIL. FIBLE TO INSUFIE PROPEF: I NSI.'FILLFIT I ON. I CERTIFY THRT t: I FIM FFIi"IILIFIFI WITH THE FIEQUIREI'IEN"I'S FOR ON-SITE SEWERS AND WELLS FIS SET FORTH 8"r' THE F1UNI. CIPFILI'T'Y OF FINCHOFIFIOE. 2: I NILL INSTALL THE S'r'STEi"I IN FICCORI)RNCE ~-,.IITH TFIE CODE:S. 3: I UNDERSTRND THFIT TFIE ON-SITE SEI.4ER S"?STEH HFI"r' REG).LIIRE ENLRFIGEi"IENT IF' THE RESIDENCE IS RErqOI)EL.,E.:[~ 1"O ~NCLUDE rdORE THRN 4 8ELbRCIOMS. ' .['l'~'.~i',lE. r.:' ~. __.-e/-~-~ :'~ · -=,m,.~ ............ RPPL :~C:RNT GErFIRGE GL FISSi'dRN I =,.=,U E:.[: El'.? ............. DFITE ....... GREA ~ ANCHORAGE! AREA BORr''$H Department of Environmental Quality 3500 Tudor Road Anchorage, Alaska 99507 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM N AM E,/L/E)L2,, LOCATION . MAILING ADDRESS c~D'¢(9 Z~/~/~Z' LEGAL DESCRIPTION /0,;""'/ ~/'/"'/ SEPTIC TANK: DISTANCE ) ~ NUMBER OF FROM WELL~:¢/~I/~(/4).. MANUFACTURER~_C~F.[ ~)~l~.~,,/ L/~¢3, MATERIAL ~Z~/, // f~2~¢b~' . COMPARTMENTS /¢] INSIDE LENGTH .INSIDE WIDTH _LIQUID DEPTH__ _LIQUID CAPACITY /',~<~ _GALLONS. SEEPAGE PIT: NUMBER OF PITS / . DIAMETER ____ OR WIDTH /~ LENGTH-."~":~,/ , DEPTH LINING MATERIAL~('-~/I//~t~[L' ' GRIM SIZE: DIAMETER z~ DEPTH:~.~2.DISTANCE FROM: TOTAL EFFECTIVE BUILDING FOUNDATION ~.~2 / NEAREST LOT LINE ~:~__4- z WELL ¢/*[?,¢~//?¢/A-~ /:-,L/. ABSORPTION AREA (WALL AREA) ~-~.r! SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE BUILDING FOUNDATION CESSPOOL APPROVED_ '7 NEAREST NEAREST SEPTIC LOT LINE SEWER LINE TANK. OTHER SOURCES · DISAPPROVED REMARKS DISTANCE FROM: SEEPAGE SYSTEM DISTANCES: INSTALLED BY: PIPE MATERIAL: LOT SLOPE: ~¢.tg:7' REMARKS: ':gC) //~/'¢ //;~ · / DIAGRAM OF SYSTEM DATE, ~¢,~,7; ~'~,,,/'('z~ Z'-~-_ APPROVED G.A.A.B. Form PW-026 GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL OUALITY SEWAGE DISPOSAL SYSTEM m APPLICATION AND PERMIT 'N"TAL,.A ',ON ,':'CAT,ON NOTE, THIS PERMIT IS NOT VALID WITHOUT ~,OIL TEST ~OIL TEST RESULTS '~¢~'~¢~'~t/_. d /'~,-~J COMPLETION DATE ANTICIPATED /~~. . PFB~AI ~ 8NF YFA~ ....... SEPTIC TANK SIZE /¢*~*'-q~ TYPE~f~-~fln(':*~,~;JgSEEPAGE A~EA SIZE TYPE MINIMUM DIB'rANcE$, REQUIREMENTS 5 FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAge PIT, 20 _~l , DR~[~ FIELD ].0 SEPTIC TANK TO SEEPAGE PIT WALL 1~ ~,~ ~EPTIC TANK ~ f~l SEEPAGE PIT ~0 f~ . DRAIN FIELD jO ~,L To N~REST ~OT UNE. ~m: WATER MAIN TO SEPTIC TANK ~0 ~9 ~EEPAGE PIT . 10 DRAIN FIELD BACKFILl. HEALTH AUTHORITY OR LICENSED DESIGNER GRJ&X~ER ANCHORAGE AREA BOROUG~P'~'x DEPA' ~ENT OF ENVIRONMENTAL QUAi. 3500 TUDOR ROAD ANCHORAGE, ALASKA 99502 CASE # ierformed For_, CowerdM T×caYa~ Date Performed 9/20/?2 ~al Description: Lot.~__ B~'~-~ 1Sub~i6~"'VaZZey Ht~,~'- n s Form Reports Soils-[~g 10 Depth ~_Feet Soil Characteristics Orsy Silt,v Grax~el (C~) Grsy~ Smnd~ Fine Gravel (C~.') w/Oravelll~ Sa~nd Se~ms ,,, Was If Yes, At What Depth? Reading Ground Water Encountered? No Date Gross Percolation R~te Proposed Insta~n: Depth Of Inlet COMMENTS: 110 ~r~. ~PF Time Net Time Seepage Pit ~ Depth to H20 Net Dro Drain Field Depth To Bottom Of Pit MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O, Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEAL'TH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING ~\'-~ - ~)ID~L -r'~,c~ . NAA# GENERAL INFORMATION Complete legal description Lot 9; B£Sbk'1; .San~,'Va~t~y~ He~Lghts' Location (site address or directions) 13240 F~ora~ Lan~. Property owner Mailing address A~aska Housln9 ¢1110904 Day phone 276-2001 C/O Dean Pa~ker 2600 Dena£i Street Suit~ 400, Anchorag~ AK Le id ng agency Mailing address__ 2001Rea£ty Day phone Dean Parker/ 2001 Agent Address _~o0 D¢.,a2~' S;,~r¢.¢.,¢: SuJ,¢¢. 400 Anchorage,, Unless otherwise requested, HAA will be held for pickup. XXX NUMBFR OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: Day phone_ ~76-9nn! AK 9950~ If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system, TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: XXX If community wast'ewater system, provide written confirmation from State ADEC attesting to the legality and status of system. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of tile validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein, I further verify that based on tile information obtained from the Municipality of Anchorage flies and from m~, investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm __S~.S_F~C.~4NF. r~R!N~ Phone ~¢-c/~'~ .~7 Address Engineer's signature . ./~..¢.~. ,, ,, ,, ,~ DHHS SIGNATURE Approved' for /~./.z, ('~)' Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments Date The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL cr.IECKLIST Legal Description: Lo'r- A, Well Data Parcel I.D. Well type A Log present (Y/N) '~ If A(A(A~B, or C, attach ADEC letter. ADEC water system number Date completed Driller Date of test Static water level Well flow Pump level1 FROM WELL LOG Total depth Cased to Casing height Sanitary seal (Y/N) Wires properly protected (Y/N) AT INSPECTION g.p.m, g.p.m. SEPARATION DISTANCES FROM WELL '¥O: Septic/holding tank on lot ~(~(_..b re_ Absorption field on lot ~EDC9 ~/-- Public sewer main Sewer service line ; On adjacent lots ; On adjacent lots ..~-'P~roleum tank Collected by: Other bacteria B. SEPTIC/HOLDING TANK DATA Date installed ~/~/ High water alarm (Y(~ .,/(~o Date of pumping Tank size /~ Compartments Foundation cleanout ~_J~) _ r~'~.~ Depression (Y/N) Alarm tested (Y,{~ C//O/~Y~ Pumper /f~¢' /7/O/-¢~" SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot .,Oo/.-'¢"/~'"'¢r~JeTJ~On adjacent lots To property line ~:D rTc~ Absorption field Surface water/drainage //o,,CE fc4.E. FdfiJ"j'- / ~649+ Foundation Water main/service line 72-026 (3/93)' Front CONTINUED ON BACK PAGE C. LIFT STATION/./o/~, E- /P/~  Manufacturer Size in gallons % Manhole/Access (Y/N) Vent (Y/N) "~ ;'~(ht sW a~eorAale~ r~ ;:cVa; lc o d e s (Y/N) SEPARATION TO: ~LerdDt On adjacent lots Surface water D. ABSORPTION FIELD DATA E. ENGINEER'S CERTIFICATION Date installed ~'/z.~./¢¢,¢~-/0~ Soil rating (GPD/Ft2) {.~./ /,;~(j2 Systemtype Length ~¢~G/ Width I~J ~' Gravelthickness ~'/ ~/ Totaldepth Total absorption area ~0~¢/~ Cleanout present'N) ~ Depression over field (Y~ Date of adequacy test ~//?/,' ~s;s ~fail)* *A; 3 for ~ ~) Bedrooms Water level in absorption field before test After test ~ Peroxide treatment (past 12 months) (Y/N) ~¢~ ~O~ If yes, give date SEPARATION DISTANCE FROM ABSORPTION FIELD TO: ~¢~ , ~ Well on lot ~ ¢~ On adjacent lots ~o cW Prope~y line Z~.~/0 To building foundation ~ ¢ / 1 ~ ~ / To existing or abandoned system on lot On adjacent lots ~0 ~ Cutbank ~o~ES~ Water main/so.ice line Sudace water ~¢ ¢~J~ Driveway, parkinCvehicle storage area ~ ~ Cudain drain ~6~ ~ ~A~ ~OTE; A~ U~p~¢EP THE ~, ~ con~e~h~U h~vo cn~c~od, o~ conformed to ~ MOA ~d H~ ~do~o~ ~ ~oc~o~ ~hff ?~ o~hi~ i~p~io~, Engineer's ~m~4 Eagle River Loop Roa~ No. 2~ ~ ~Eagie Ely;r, Alaska ~577 -- / /~ ~b~d HAA Fee $ Date of Payment Waiver Fee $ Date of Payment Receipt Number 72-026 (3/93)* Back N¥ld ]lis I WALTER J. HIOKEL, GOVERNOR ~EPT. O~ ENV~ONMEN'TA~, CONSERVATION ANCHORAGE DISTRICT OFFICE 800 E. DIMOND BLVD., SUITE 3-470 ANCHORAGE, ALASKA 99515 (907) 349-7755 May 13, 1993 Mr. Ray Shafer S & S Engineering SUBJECT: Lot 9, Block 1, Sun Valley Heights South Class "A" Public Water System, PWSID 213962 Dear Mr. Sharer: I have completed a review of this office's files concerning the monitoring status of the above-referenced Class "A" Public Water System and found the following: The last satisfactory Total Coliform Bacteria Sample results was submitted to this Department on April 28, 1993. This does meet the provisions of 18 AAC 80.200(a), of the State Drinking Water Regulations. The last inorganic Chemical Contaminants Sample results were submitted to this Department on July 8, 1991. This does meet the provisions of 18 AAC 80.200(a), of the State Drinking Water Regulations. The last Radioactive Contaminants Sample results were submitted to the Department on April 29, 1992. This does meet the provisions of 18 AAC 80.200(a), State Drinking Water Regulations. The last Organic Chemical Contaminants/Volatile Organic Chemical (VOC) were submitted to this Department on October 29, 1992. Based on analysis of the previous VOC samples results have been satisfactory. This does meet the provisions of 18 AAC 80.200(a), State Drinking Water Regulations. issuance of this letter does not imply that the above-referenced Class "A" Public Water System is in compliance with other provisions of the State Drinking Regulations. Unless otherwise noted, this letter is valid for 30 days and is for the specified legal description noted above only. If you have any questions on the above information, please do not hesitate to contact this office at 349-7755. Sincerely, Environmental Eng. Asst. II STATE OF ALASKA DEPARTMENT OF ENVIRONMENTAl. CONSERVATION APPROVAL OF ON-SITE RESIDENTIAL WATER AND SEWEr{ SYSTEMS PROPI--RTY DESCRIPTION Lot, Block & Subdivision or U,S. Su~ey Lot 9, Block 1 Sun Valley Heights South PWSID no. 213962 This approval does not constitute a guarantee of any kind, explicit or implied, as to the performance of the water supply and wastewater disposal systems. WATER SUPPLY A recent water sample was tested and found to meet Department of Environmental Conservation drink- ing water standards for total coliform bacteria. T~Ue Environmental oate 199]$ Eng. Asst. II May 12, WASTEWATER DISPOSAL The domestic"~.~ater system was: [] inspected by the D'ep. artment of Environmental Conservation an..d..f, dund to be in compliance with applicable requiremei~.~18 AAC 72; [] inspected by a Professional'E--~.gineer who certifiesJ~fi't the system complies with applicable re- quirements of 18 AAC 72; ~ ~ [] installed b~yst~plies with applicable requirements of 18 AAC 72; or [] tested by ~tthe performance of the system is satisfactory and that th~aration distances specified in 18 AAC 72. This appr~a [] single family ~ m ulti.family~ith a total of. bedrooms. 18.0404 (Rev. 8185) DISTRIBUTION: WHITE--BANK/LENDING INSTn'UTION; CANARY--APPLICAN~ PINK--DEPARTMENT .j APPLI( NT FILLS OUT UPPER HAl ONLY Address .-2 -~ Address %' ~ (~ )~ " Realty Co. & Agent ~,;~¢~ Legal Description ..~" ~ M¢ltlple Family No. of Bedrooms Zip Code Phone Phone Water Supply [~ Individual Community Sewer Disposal Individual E Publlc Utility [~ Holding Tank ATTACH WELL LOG. A well Icg Is required for all wells drilled sll~ce June 1975, For wells drilled prior to that date, give well depth (attach Icg if available), Year Individual Inslalled: C~F~, ~2 /) /9 /-/' .-~/.~/"~ When Connected to Public Utility: NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSIN(~;'CAN BE INITIATED. 07- Time Time Time Date Date Date Inspector Inspector Inspector Inspector Field Notes: - ) DONDITIONAL APPROVAL* "CONDITIONS OF APPROVAL Soils Rating J Date Sewer Inst~lled Well To Absorption Area Well to Tank Well Log Received Septic T&nk Size ARCTIC ENGINEERS, INC. August 19, 1983 AEII~ 83-013.-22 Terry Davis Floral Lane Anchorage, Alaska LEGAL: OWNER: HOUSE TYPE: WATER: SEPTIC SYSTEM: TEST DATE: PROCEDURE: SEPTIC SYSTEM ADEQUACY TEST Lot 9, Block 1, SunValley Heights Subdivision Terry and Patricia Davis 4-Bedroom, 2-Story, Single Family Community Well From MOA Records: Tank: Absorption System: ~fosorption Area: Approval Date: August 17, 1983 1250 gallon, 2 compartment, steel Seepage Pit, 2 concrete rings 504 sq. ft. SepteImber 26, 1972 House water use was not kept at a minimum on Aug. 17, prior to the adequacy test, which was started at 2 pm. Water from a tank truck was dumped into the pit in 100 gallon increments with liquid rise measured a~ter each increment. When 500 gallons had been added, the pit became full. At that time, addition of water was halted and the septic tank was pumped. Terry Davis Adequacy Test 83-013-22 --2-- PROCEDURE: RESULTS: The calculated rate of rise in the pit was 500 gallons per foot. Absorption monitoring was carried out for 73 minutes after pumping the septic tank. The resultant plot of absorption vs. time, with the extrapolated daily absorption capacity, is included. The plot of absorption vs. time yielded a daily absorption capacity of 410 gallons per day. The required absorption capacity for a 4-bedroom house is 600 gallons per day. The soil absorption system fails to meet the Municipality of ~chorage requirements.