HomeMy WebLinkAboutSUN VALLEY HEIGHTS BLK 5 LT 9
GR~ ~,TER ANCHORAGE ARI.:A BOROV'-"H
D,,.ARTME~T 0F ENVIRONMENTAL QUALi ,
3500 TUT)OR ROAD ANCHORAGE, ALASKA 99507 279-8686
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
MAILING
.... ADDRESS
PHONE
SEPTIC TANK:
DISTANCE FROM WELL
LIQUID CAPACITY /~-~-' Z') GALLONS.
_~¢ NUMBER OF
MATERIAL ,-¢ '~';~'~"' - .COMPARTMENIS
INSIDE LENGTH ~ INSIDE WIDTH.
LIQUID 4 ....
DEPTH __
SEEPAGE SYSTEM: SEEPAGE PIT:
NUMBER OF PITS / OUTSIDE DIAMETER_
LINING MATERIALrJ"',~
DISTANCE FROM WELL
, LENGTH~~ ~ __, DEPTH
BUILDING FOUNDATION
NEAREST LOT LINE~,;~,~' ~?~?~-'~?~TO[AL EFFECTIVE ABSORPTION AREA (WALL AREAl ~;~¢'" '"~
SQ. FT.
TILE DRAIN FIELD:
DEPTH OF FILTER MATERIAL BENEATli TILE
ABSORPT~ .SQ, FT. LENGTH OF EACH LINE
DEPTH: TOP OF TILE TO FINISH GRADE
WELL: TYPE ,~,~/~-~z:,"~'~ _, DEPTH .._,..~ DISTANCE FROM
., BUILDING FOUNDATION.
/ NEAREST c.~.~ SEPTIC c._._~ SEEPAGE
LOT LINE , SEWER LINE ., TANK , SYSTEM___
DIAGRAM OF SYSTEM
DISTANCES:
TOTAL LENGTH
OF LINES
IN, TOTAL EFFECTIVE
IN. ABOVE TILE
WATER
, CESSPOOL_~-~-~ , SOURCES
-- G.A.A,B. -'-'
DATE
GREAl'ER ANCHORAGE"' AREA BOROUGH
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
PERMIT NO,
INSTALLATION OF: SEPTIC TANK
TYPE AND SIZE OF FACILITY TO BE SERVED
, DRAIN FIELD .
, OTHER
SOIL TEST RESULTS ~/// '~'"~ /27 ,/~.~U ..~/~':/'/?../~.~-':,¢~2-"¢ NOTE, THIS PERMIT iS NOT VALID WITHOIJT SOIL TEST
COMPLETION DATE ANTICIPATED ~.,/
FINAL IN,~PECTION: 24 HOLIR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL IN~PEGTION BY THE
HEALTH DEPARTMENT AUTHORITY WILL BI". SUBJECT TO PROSECUTION.
SEPTIC TANK SIZE /'~'~r-~) TYPE :h'//' I~/~ SEEPAGE AREA SIZE :/--~7///~¢ TYP/E ~/
MINIMUM DISTANCE~, REQUIREMENTS
FOUNDATION TO SEPTIC TANK ~I--
FOUNDATION TO SEEPAGE PIT
SEPTIC TANI'( TO SEEPAGE PIT WALL
SEPTIC TANK · SEEPAGE PIT
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK
DRAIN FIELD
WATER MAIN TO SEPTIC TANK [ ~'!
DRAIN FIELD .....
, DRAIN FIELD
DRAIN FIELD
SEEPAGE PIT ·
ALSO CONSIDER AREA WELLS.
£
SEPTIC TANK, -- --, SEEPAGE PIT , DRAIN FIELD -
TO RIVER, LAKE, STREAM,
.CAS~T IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
4 INCH D]AMETER CAST IRON SIPHON PiPeS ON SEPTIC TANK AND SEEPAGE Pit
FITTED WITH A}R'['iGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BORO ULATIONS REGARDING INSTALLATION. //~
HEALTH AUTHORITY
OR
LICENSED DESIGNER
I CERTIFY T~T I AM FAMILIAR With THE REQUIREMENTS OF GReater ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND That THE ABOVE
GRI:ATER ANCHORAGE AREA BOROUG~~
DEPi 'MENT OF ENVIRORMFNTAL QUA
3500 IUDOR ROAD
ANCHORAGE, ALASKA 99502
CASE #
Performed For Fred wilkes
Legal Descrip~: Lot_~.Block_
This Form Reports Soils Log x
Date Performed 4/17/72
Subdivision Sun Valley~s
P-~-~-~-6-Ta'tiO'~ Test
Depth
Fe~ t
Soil Characteristics
Gray sandy gravel (GW)
with silty gravel seams from
6 to 8'
Was Ground Water Encountered? no
If Yes, At What Depth?
7
Reading Date Gross Time Net Time Depth to Net Drop
e~ o~61-fil-6'~ Rate
Proposed Insta~T~F~on: Seepage P~t x
Depth Of Inlet Depth To
COMMENTS:
ll0_~quare feet of drainage area is required~r bedroom.
Drain Fie'Id
Bottom Of Pit ~ Tr~
Y~'st Perform~F-Br~..
P~ E. carlim]Le__, -
Oa-"t~--C~-F~-~i~ BY:National Testin~_~S~vs. Inc.
Date'.
(-
MUNICIPALITY OF ANCHORA 3E
i DEPA.TMENT OF HEALTH · ENVmONMENTAL PROTECTION
~ ~ 825 LStre.t-Anshorage Alaska 99501
ENV RONMENTAL ENGINEERING DIVISION
Telephone 264-4720
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILI'rlES
DIRECTIONS: Complete all parts on psge 1. Incomplete requests will not be proc~sed. PJease allow ten H0) days for processing.
1. PROPERTYOWNER ' PHONE~
M~LING ADDRESS
PROPERTYRESIDENTJifd~ffere~tJro~above) J PHONE
~Ai L[ NG AD~
3' LENDING INSTITUTION -- ~ ~ , ~ ~. I PHONE
4, REAL,OH/AGENT ~ PHONE
STHEET L~OATIO~ ' J
6, TYPE DF RESIDENCE
I
[] SINGLE FAMILY
?, WATi~R S~up,MLUyLTIPLE FAMILY
OOMMUN"'Y
PUBLIC UTILITY
8. ~EWAGE DI~POSAE ~YaTEM
INDIVl DUAL/ON-SITE
~Bkl¢ ~TIUTY
NUMSER OF BEDROOMS '
One ~ Four []
Other_
[] Two L_J Five
[] Three [] Six
ATTACH WELL LOG. A well log is required for ell wells drilled
since June 1975. For wells drilled arIor to that date. q ve we
depth (attach log if available.)
"if individual/on-site, gwe instal etlon date J' ~-~.~.. .
[f system is over two [2) veers old an adequacy test is required
by this Departmen£.
72-010(3/7BI
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED
THIS SIDE FOR OFFICIAL USE ONL
DATE RECEIVED
INSPECTION APPOINTMENTS
TIME TIME TIME
DATE DATE DATE
INSPECTOR INSPECTOR INSPECTOR
DIRECTIONS:
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS
[] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER
[] MULTIPLE FAMILY {~ TWO [] FOUR [~] SiX
PERMIT NUMBER
2. WATER SUPPLY
[] INDIVIDUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[]INDIVIDUAL/ON -SITE DATE INSTALLED
E~]PU BLIC UTILITY L.~ ~"~ '~.~
Connection Verified _ INSTALLER
~ptic Tan,.~k ~r [~Holding Tan~:
Size: I ~'~''' If Tank is homemade SOILS RATING
give dimensions:
TYPE OF TANK MANUFACTURER
TOTAL ABSORPTION AREA MATERIAL
~k~i~ Sewer Line Nearest Lot
4. DISTANCES Septic/Holding Tan bsorption Area Line
WELL TO:
Absorption Area to nearest Lot Line
5, COMMENTS
[~/APPROVED FOR ~'~ BEDROOMS
//CONDITIONAL APPROVAL (letter must accompany certificate)
DISAPPROVED
72-010 (Rev, 3/78)
])ate
t I / ';-?
ALASV ' f · ~",~RTMENT OF IIEALTH AND SOCIAL ,~"9~' ~S
DIVISION OF PUBLIC HEALTH ' ~
Lab. No.
BACTERIOLOGICAL WATER ANALYSIS
;
Office
PLEASE MAIL RESULTS TO:
ADDRESS ' ~
CITY_ ' ':
Sample collected by__ i '.~
ZIP CODE__
Phone No.
Date Collected Time
Sampling Address / :' ~ · .
Specific place of collection
REASON FOR SAMPLE SUBMISSION:
[] Illness suspected
[] Health Regulated Establishment
[] Other , ] ~.
WATER SAMPLE SOURCE
[] Well Type of casing ":' '
[] hnproved (Enclosed, Covered) Spring
[] Surface (Reservoir, stream, lake)
[] Holding Tank
[] Other
Analysis shows this WATER SAMPLE to be:
~Satisfactory
[] Unsatisfactory'
[] Questionable [-] submit other sa~nple
[-] Sample too 10rig· in transit to indicate reliable results.
Sample should not be over 48 hours old at time of
examination.
[] Boitie broken or leaked in transit.
[] Other
SANiTARIAN'S RI~MARKS
Sanitarian's Signature:
I.R.. EA D INSTRUCTIONS
BEFORE
_COLLECTING SAMPLE
06-1220 (e) BA~TERIOLOG ICAL WATER ANALYSIS RECORD
Rev. 1978
July 24, 1978
851563
United Bank Alaska
2600 Denali Street
Anchorage, Alaska 99503
Attention: Jody Nardini
Re: Adequacy Test of Existing Sanitary Sewer System; Lot 9, Block 5, Sun
Valley Heights Subdivision, Anchorage, Alaska
Dear Ms. Nardini:
Per the request of Mr. Barry Brogan of Taylor Realty of July 17, 1978, we
conducted a test of the sanitary sewer system on the above described
property.
The septic tank was pumped prior to the performance of the test on the crib.
During the test the liquid level in the crib was measured, before and after
the addition of 1500 gallons of water. All liquid levels were measured below
the top of the standpipe and are summarized in the following table.
Liquid Level
Before Water Added
Liquid Level
After Water Added
Total Rise in
Liquid Level
5.0' 3.2' 1.8'
The water level rose 1.8' with the addition of 1500 gallons of water, indi-
cating an acceptance rate ef 69.4 gallons per inch in the crib. Twenty-four
hours later the liquid level was again measured and found to be 4.8'. It had
dropped 1.6 feet or 19.2 inches. This indicates an average effluent accept-
ance rate of 1332.5 ga]Ions per day for the surrounding soils. If the four-
plex on ~he property is to house 10 people the average load on the system can
be expected to be approximately 750 gallons per day. We can therefore con-
clude that the system is disposing of efflue~Lt at an adequate rate for a
four-plex housing 10 people.
July 24, 1978
United Bank Alaska
Page -2-
We appreciate thls opportunity to be of service to you. Please contact us if
you have any questions concerning this test or if we can be of additional
service.
Very truly yours,
R&M CONSULTANTS, INC. .-~ ~/~th
Edward Y'armak, Jrf
Geotechnical Engineer . Manager
EY/kah