Loading...
HomeMy WebLinkAboutT12N R3W SEC 15 LT 5612N R3W EC ON �-15 #015-052-27 Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSPXXXXXX PID Number: 015-052-27 Dwelling: RE Single Family (SF) F-1 with ADU F] Duplex (D) El Two Single Family Project: El New RN Upgrade Name Earl W & Cheri D Ford ABSORPTION FIELD RN Deep Trench R Wide Trench R Bed El Mound Site Address 9441 Elmore Road El Other Phone Number of Bedrooms Soil Rating Total depth from original grade 13 10.8 GPD/SF 15.5-17.8 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 10.0-12.3 FL Gravel depth beneath pipe 5.5 Ft. Subdivision Block Lot T12N R3W SECTION 15 56 Fill added above original grade 0 Ft. Gravel length 52 Ft. Township Range Section 12N 3W 15 Gravel width 3.0 Ft. Beds: Number of Lines n/a Distance between lines n/a Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 572 Ft� 1 n/a Ft. Well 100'+ 100'+ NA NA 25'+ TANK El Septic [I S.T.E.P. El Holding El Other Manufacturer Capacity Gal. Surface Water 100'+ 100'+ NA NA Material Number of compartments Lot Line 51+ 10'+ NA NA NA Foundation 10 1+ 10 NA NA LIFT STATION Manufacturer Capacity Gal. Remarks See attached letter. Alarm location Electrical installed by PIPE MATERIAL House to tank Tankto 3034 drainfield Installer — Contractor/Owner Install Drainfield 3034 CO/MT 3034 inspector PES BENCH MARK (Assumed elevation) 102.95 ft Inspection r 07/09/24 Location and description dates: nd 2 See Site Plan, top of concrete support for barn porch rd 3 4t h ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date ....... .. . . ..... OVA...... . A ........ Steven R. Pcnnar-)e C E 814 Aw `lie oell,31-2# "W 4W Septic Y stem Approv d Date Note: this approval does not include well permit requirements. (Rev 05/02/18) Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska Subject: T12N R3W Section 15 Lot 56 Septic System Documentation & Additional Information The purpose of this letter is to provide the Department with additional information regarding the supplied record drawing to document an existing drain field which was installed without a permit. The conventional on-site wastewater treatment system on this lot serves an existing three (3) bedroom house. The treatment system consists of a steel 1250-gallon septic tank (installed in 2004 under permit no. SW030246) and a deep trench absorption field. The subject absorption field was installed as an upgrade to the previously existing drain field without a permit –by the owner of the property. PES was contracted by the owner to document the drain field and provide record drawings for MOA documentation. The attached record drawing reflects data collected in the field by PES and owner/contractor provided documentation. The owner was informed by the Onsite Department that a test hole would be required to document the system. The test hole was performed by Ground Breakers, LLC. without PES present. The soils log for this test hole is attached. No groundwater was observed in the test hole monitor tube o f the test hole conducted by Ground Breakers, LLC. on 06/2524 and 07/02/2024, with PES verification on 07/09/2024. A test hole was previously performed on this lot by Jim Mack on 10/13/1976. Groundwater and bedrock were not encountered during the excavation of this test hole. No groundwater was observed in this test hole monitor tube after 7-days. PES performed an additional test hole on 08/07/2024. Groundwater and bedrock were not encountered during the excavation of this test hole. The test hole performed by PES and corresponding sieve analysis results appear to support the test hole and percolation test performed by Jim Mack on 10/13/1976. Disclaimer: PES verified the above noted information to the maximum extent feasible. PES did not conduct percolation tests on this property. The test hole conducted by Ground Breakers, LLC. may verify separation distances to groundwater and bedrock. The application rates used for the design of the wastewater treatment system were based on Jim Mack’s 10/13/1976 percolation test and verified by surrounding soils. The system has been operating for some time with no reported issues. The owner of the property hired PES to document the wastewater treatment system installed on the property in order to obtain an MOA approval to operate. PES shall not be held liable by this or any other subsequent owner of the property, the Municipality of Anchorage, the State of Alaska, or the Environmental Protection Agency for any components of the wastewater treatment system on this property which might violate State or Federal laws. Sincerely, SRP Steven R. Pannone, P.E. F. ASCE Owner/Civil Engineer 23 August 2024 PROFILE PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) COMMENTS: Test hole excavated by Ground Breakers, LLC. PERFORMED BY: PANNONE ENGINEERING SERVICES, LLC. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. SOILS LOG 040.002 Crowther Associates 1632 Bellevue Circle / Anchorage, Alaska 99515 Telephone (907) 349-2198 / E mail: 907crowther@gmail.com Date:August 13, 2024 Client:Pannone Engineering Services, Steve and Dan Project:4991 Elmore Road Anchorge, Alaska Particle Size Distribution Table (percent passing subject sieve size) Sample Source 14’17’ Moisture Content 10.4%12.1% Sieve Size Percent Finer Percent Finer Percent Finer Percent Finer 3 inch 100 100 1-1/2 inch 100 100 ¾ inch 90 92 #4 83 61 #10 80 76 #40 69 66 #100 47 44 #200 44 38 0.02 mm xx xx Classification Silty Sand (SM) Silty Sandy Gravel (GM) Invoice 220 // / // / // / // / // / // / // / ///X X X X X X X X X X X X X X X X OH E OH E OH E OH E OH E OH E 50'50' 50'50' WORK ORDER No:DATE:SCALE: DRAWN: CB CHECKED: ME/RL ZONING: 1"=50'Apr 26,2024 R6 GRID No:FB BOOK/PAGE: SW2436 167/59 SURVEY CERTIFICATION: FARPOINT has conducted a physical survey of the subject property, the improvements situated thereon are within the property lines as shown. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the Plat used for this survey. NOTE: Under no circumstances should any data hereon be used for construction or for the establishing of property lines. PREPARED FOR: Earl Ford ASBUILT SURVEY OF: BLM Lot 56, T12N R3W Section 15, Anchorage, Alaska Found Rebar Cleanout Well Elec Meter Farpoint Land Services, LLC SURVEYING, MAPPING, LAND PLANNING, GIS 1131 E. 76th Ave., Suite 101 Anchorage, Alaska 99518 FarpointAK.com (907) 522-7770 survey@farpointak.com Robert O. Lumpkin No. 10459 R E GIST EREDPROFESSIO N A L L A N D S URVEYOR SERVI N G A L A SKA SI N C E 1 9 8 2 1.Bearings and distances derived from recorded plats unless otherwise noted. 2.Not all monumentation for this survey may be shown on this document. 3.Excepting for gross negligence, the liability for this survey shall not exceed the cost of preparing this survey. Found Almon Gas Meter Power Pole 4/26/24 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241233 Work Type: Septic Upgrade Tax Code Number: 01505227000 Site Legal Address: T12N R3W SEC 15 LT 56 G:2436 Site Mailing Address: 9441 Abbott Loop RD, Dupl 000002, Anchorage Owner: FORD EARL W & CHERI D Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: 0 Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 8/23/2024 8/23/2025 46228 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: ( S :5 �� % I % -5 Date: Issued By: �� 9' Date: 3 ON -SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 01505227 Property owner(s) Earl Ford Mailing address Site address 9441 Elmore Rd Day phone Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) T1 2N R3W SEcl 5 L56 Lot Size - Sq. Ft. Number of Bedrooms APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (Z all that apply) Absorption Field nx Initial ❑ Single Family (SF) nx (w/wo ADU) Septic Tank nx❑Upgrade Duplex (D) E] Holding Tank ❑ Renewal El Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. SRP (Signature of property owner or authorized agent) After the fact permit to provide documentation of bootlegged systen Permit/Rush Fees: Waiver Fees: Date of Payment: Receipt Number: Permit No. 2- 1 S 3 Date of Payment: Receipt Number: Waiver No Permit App-'-'- : - "-.,:c , Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program, 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 •Alww.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 Onsite Wastewater Disposal System and/or Well Inspection Report SW030246 PID Number. 015-052-27 Permit Number. Name: Wastewater System: ❑ New ■ Upgrade EARL & SHERRY FORD Address: 9441 ABBOTT LOOP RD * ANCHORAGE, AK 99507 ABSORPTION FIELD Phone: No. of Bedroom; 3 O Deep Trench O Shallow Trench O Bed D Mound Dot D (907) 346-2588 Mang Total Depth fowl onpinal LEGAL DESCRIPTION WD/54. R /° Block: Lot: Subdivision: Depth to pipe bottom from 90910W goat arasel "M a eau pee: — 56 Ft. R Township: 12N Range. 3W Section: 15 FM oeded above e,lglnoi eras.: R or" *Wm: Number of Wise: Distance bbasn Nee WELL: ❑ New ❑ Upgrade R R Ck" catch ",C): cased T®�;p TeW ebs rpitm Pee nwtww: R R SO. R -installer Dale blebRed: DraNn Dob DrIINd: SWb Wafer Level: SONSHINE ENTERPRISE 6/1/2004 R „.N: pomp Set At as ft Neght Jkbaee cmww: TANK VM R R SEPARATION DISTANCES ■Septic 0Holding DS.T.E.P. bother To septic Meption Utt Molding bpe/PrlvaN Nasufoatu,ef: capo r in plbne: ANCHORAGE TANK 1250 From Tonk Fold station Tonk saver tis as uab�b Nlanber of ,"mparb a w: Well too'+ — — — 25'+ STEEL 2 — — — LIFT STATION Surface water 100'+ — Sias In gonwo: tlanufacb ere Lot Line 5'+ — — — as Neel at amp r Worm et• Foundation 5'+ — — — — Purrq Wb a bepeoaaoe gr/ermed bY: Curtain Drain NONE KNOW BENCH MARK Remarks: teasDen ownpw. TOP OF CONCRETE SLAB BY FRONT DOOR "s"ue"d ElnnDon. 100.00 R ENGINEER'S SEAL d0 o� OF. V Cl) *ooh GEGe Inspections performed by: Ltd. Dates: 1st 6/1/2004 . . 2nd — 3rd — O.� '....e Go ess: ` Development ervices Department Approval Ap+\ ' by Date: A F°v Op"�'rofesgtooao7 Reviewed and approved �OO�000� (RW. 1/00 PERMIT NUMBER: AS -BUILT DRAWING PAR°��-NUMBER: SWO30246 015-052-27 [SEPTIC ARE�D \\ / j /----------- --- �------�T---- � sNED °fes""; \ isnNG 2 BEDROOM ••1 ?'ri HOUSE pafi' / C / GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS S GENERAL CONTRACTORS"^ 5701 E. TUDOR ROAD SUITE 101 • AMC RAGE, AK 99507 • FNONE (907)M-61" PREPARED FOR: PHONE NUMBER: SHERRY FORD 346-2588 LEGAL DESCRIPTION: T12N, R3W, SECTION 15; LOT 56 TYPE OF WORK: AS—BUILT DRAWING OF SEPTIC TANK UPGRADE SEPTIC TANK R.A.L. 1 " = 40' NUMBER: 2 OF 3 Arm FCO 27.80 39.00 Sit 39.85 47.80 Sit 47.20 53.80 DBL1 50.80 58.30 DBL2 51.20 58.90 J A G�ss: e ` — 953 :< PERMR NUMBER: AS -BUILT DRAWING PARCEL NUMBER: SWO30246 015-052-27 -103.11-103.69 ST2 OF TOP OF TANK INLET - 94: n U NEW 1250 GALLON INVERT OF SUNG SEPTIC TANK AT INLET - 93.69 TOP OF TANK AT OUTLEr - 94.46 VERT OF BUNG AT OUTLET - 93.73 R.A.L. GARNESS ENGINEERING GROUP, Ltd. * : 4 9* sGA�: CONSULTANTS S GENERAL CONTRACTORS �+�---�- N.T.S. •.. "' . "' '•"" 5701 L NDOR ROAD. SURE 101 ANCHORAGE, AK "307 • F110NE -6170 41 PHONE NUMBER: PAGE NUMBER: PREPARED FOR: 346-2588 3 OF 3 •', ffr, . r) y . or ss:' SHERRY FORD O a 79 ; d LEGAL DESCRIPTION: Tl 2N, R3W, SECTION 15; LOT 56 ` 4 ^sd O�Ob000�� 9�F rofeoslot, TWE OF WORK: PROFILE AS -BUILT OF SEPTIC TANK UPGRADE MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Renewal Permit Number: SW030246 Legal Description:Q 2N123W`SEC t5'CT" 56^ Design Engineer: 0041 AK Water & Wastewater Consultant Owner Name: Cheri Ford Owner Address: 9441 ABBOTT LOOP RD ANCHORAGE, AK 99507-4221 Date Issued: Jul 15, 2003 Expiration Date: Jul 14, 2004 Parcel ID: 015-052-27 Site Address: 009441 ABBOTT LOOP RD Lot Size: 46228 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: ❑ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ El Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By. Issued By. Date: 7 -t5 -o3 Date: — Q I Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. s "' P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 _ ON-SITESEWERMELL PERMIT APPLICATION.. FOR A SINGLE FAMILY DWELLING Parcel I.D. o, cz�--n S Z —Zl Permit Number SWO3024L Property Mailing address (1 ) k6VD6W Day phone t Z a Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) �� Zw 3 VJ S (-C 15 - Legal 5 Legal description (Section, Township & Range) Lot Size Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms 3 Sewer Only ❑ Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Waiver Fees: i Date of Payment:__))Q3 QDate of Payment: Receipt Number: ' "i Receipt Number: (Rev. 12/00) �X pima- 7�s%3 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW020255 Legal Description: T1 2N R3W SEC 15 LT 56 Design Engineer: 0041 AK Water & Wastewater Consultarc Owner Name: Cheri Ford Owner Address: 9441 ABBOTT LOOP RD ANCHORAGE. AK 99507-4221 Date Issued: Jul 30, 2002 Expiration Date: Jul 30, 2003 Parcel ID: 015-052-27 Site Address: 009441 ABBOTT LOOP RD Lot Size: 46228 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: ❑ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage Al construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: i Date:I r Municipality of Anchorage y` Development Services Department Building Safety Division a On -Site Water & Wastewater Program 4700 South Bragaw St, P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. _ 01 S—OS — 7 Permit Number SLv0202SS Property owner(s) SHERRY FORD Day phone _ 346—"AR Mailing address (1) 9.441 ABBOT LOOP ROAD + ANCHORAGE AK 99sn7 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) N/A Legal description (Section, Township & Range) SECTION 15- Tt N. R3W: LOT ss Lot Size_ Ll 622, $ Acre q.Ft. Number of Bedrooms THIS APPLICATION IS FOR: Sewer only ❑ Well Only ❑ Sewer and Well \ ❑ Water Storage ❑ Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Cl Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ i I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. ALASKA WATER dt WASTEWATER CONSULTANTS INC. Permit Date of Payment: Waiver Fees Date of Payment: Receipt Number. I Receipt Number: ALASKA WATER WASTEWATER CONSULTANTS, INC. ft July 24, 2002 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragraw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Septic Tank Upgrade for Lot 56; T12N, R3W, Section 15 To whom it may concern: The existing 2 bedroom house is currently being upgraded to a 3 bedroom house. The existing 3 bedroom septic system contains a 1250 gallon septic tank and is currently in the area of the proposed addition. We are proposing that the existing 1250 gallon septic tank be abandoned per UPC code and be replaced with a 1000 gallon septic tank. 1. SURFACE WATERS: There are no surface waters within 100 feet of the proposed upgrade. 2. TOPOGRAPHY: There are no slope concerns. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your NOTE: Attached is a site plan drawing, a design drawing„ and a S page construction specification letter which are all part of the design package for this septic system. 6901 Debaa Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 • Fax: (907) 338-3246 * Website: akwwc.com' 2 BEDROOM I HOUSE I I iI I 1 1 I I I 1 I I I , I I 1 LILLESTON —'----7---------- ---------------- I I TI A, RX, SECTION 15 LOT 49E STREET 0 T12N, RX SECTION 15 LOT 50 � T12N, RSW, SECTION 15 LOT 54A I ` SHED � .--•-- i i DATE 7/24/2002 IXISTING SEPTIC SYSTEM 41rPROPOSED / j 772N, R3W, SECTION 15 DRAWN BY: NUPGRADEC LOT SS Z.T.G. P.• (:a& tD 4 SCALE, 6901 DEBARR ROAD, SUITE 26 • ANCHORAGE, AK 99504 • PHONE (907)3374179 • FM (907)338-3246 1"= 100' PROPOSED NEW I 1 PACE NUMBER: ADDITION 1 Or 1A `•••••••.. e Garn sl ° •. —7 3 � � �aa�r 1 T12N, R3W, SECNON 15 T12N, R3W, SECTION 15; LOT 56 LOT 55 ' • , \ a °�° • .. • . • Y`P1� �Vjt°pr)/sssiolla TYPE OF WORK: SITE PLAN ONUS SECTION 15 T12N, RXLOT 57 2� //, 111 6 1 I\. 6j1�� � T12N, RSW, SECTION 15 LOT 54A I I �� DATE 7/24/2002 r S�a� DRAWN BY: ALASKA WATER & WASTEWATER Z.T.G. P.• CONSULTANTS, INC. 4 SCALE, 6901 DEBARR ROAD, SUITE 26 • ANCHORAGE, AK 99504 • PHONE (907)3374179 • FM (907)338-3246 1"= 100' • " ""' •` .. PREPARED FOR PHONE NUMBER: SHERRY FORD 346-2588 PACE NUMBER: 1 Or 1A `•••••••.. e Garn sl ° •. —7 3 � � �aa�r LEGAL DESCRIP710N: T12N, R3W, SECTION 15; LOT 56 ' • , \ a °�° • .. • . • Y`P1� �Vjt°pr)/sssiolla TYPE OF WORK: SITE PLAN \ A [SEPTIC \ ARE�D / ----------- �--- -------- ---J INSTALL CLEAN OUT E7(ISTINC 1250 SEPNC TANK \ SHED TO BE ABANDONED PER UPC TIE INTO \ LATERAL EXISTING DRAINFlELD ' INSTALL DOUBLE CLEANOUTS 1 EXISTING ' PROPOSED NEW 1000 2 BEDROOM GALLON SEPTIC TANK HOUSE / INSTALLTION CLEANOUT / HOUSE BEING UPGRADED FROM 2 BEDROOMS TO 3 BEDROOMS E�� DATE: 7/24/2002 ... DRAWN BY: ALASKA WATER & WASTEWATER Z.T.G. �:. ' s�LE 1" — 40• CONSULTANTS,iNC. TA .,t 4 ...... 6901 DEBARR ROAD, SUITE 28 NCHORAGE. AN 99504 •PHONE (907)557-0179 • FAX (907)538-3246 PREPARED FOR: PHONE NUMBER: PACE NUMBER:- UMBER:SHERRY SHERRYFORD 346-25882 OF 2 .••"•• of A. U S.,. a 7953 a . ' • �a� ��n°tee ' • .......olp Y4000000Lol`� LEGAL DESCRIPTION: T12N, R3W, SECTION 15; LOT 56 TYPE OF WORK: PROPOSEC NEW SEPTIC TANK UPGRADE GRED.. L�R ANCHORAGE AREA BOR.. JGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM__ y _ 1 NAME__._.-/-%%+� !��—'�— MAILING ADDRESS_ JI PHONE G / LEGAL DESCRIPTION— SEPTIC TANK: DISTANCE NUMBER OF _ FROM WELL_ _— MANUFACTURER _ZAP�— MATERIAL _ __. COMPARTMENTS -7 -- INSIDE LENGTH %' / __ INSIDE WIDTH-- LIQUID DEPTH _______ LIQUID CAPACITY,---- GALLONS. TILE DRAIN FIELD: _/ _ TOTAL LENGTH � � DISTANCE FROM WELL _10e) FOUNDATION NEAREST LOT LINE__) OF LINES .V__ NUMBER OF LINES—DISTANCE BETWEEN LINES __ TRENCH WIDTH _-'�__/IN. TOTAL. EFFECTIVE ABSORPTION AREA SQ. FT. LENGTH OF EACH LINE— //L� n J DEPTH OF FILTER DEPTH: TOP OP TILE r0 FINISH GRADE MATERIAL BENEATH TILE _e? .�- IN. ABOVE TILE ✓—_—IN. WELL: TYPE- —_"`-P _-_ CONST RUCT ION— �� _.-. —.--DEPTH_ DISTANCE FROM: BUILDING NEAREST NEAREST SEPTIC SEEPAGE ! FOUNDATION_— LOT LINE__, SEWER LINE, TANK SYSTEM���NJ CESSPOOL OTHER SOURCES APPROVED DISA..PPP/ROVED DISTANCES: G---' INSTALLED BY: SEWER LINE DEPTH: PIPE MATERIAL: REMARKS 1 (6a n/I o) LOT SLOPE: _._ . __— -- _ Ale- 1 / REMARKS: -- DATE—/" Fbnn EQ -032 DIAGRAM OF SYSTEM 04 ROVED FA G.A.A.B. �P9Ati iv HKY ILA 1: L; A. I" VAL. 1. U "e Ls &_ Ps rA L. pi=v< ro uN rn DEPARTMENT ' HEALTH AND ENVIRONMENTAL ?OTECTION � 2516 E. iUDOR RD./ ANCHORAGE, HK t/507 276-2221 ���][-8-��� �����8^U����� ��El FAU�11U�-�a/ �/�',/'/� woo - PERMIT NO.^'' --- APPLICANT y' ROB RTIN 3126 EAST 72ND F|V[i: 344-2911 '---- L(}[l�lTI[|�| F|BB(T|'TL�OOP LEGAL L56 SEC 15 T12N R]W LOT SIZE 108000 SQUARE FEET TYPE OF SOIL HBSORBTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS = ] SOIL RATING (SQ FT/BR)= 150 / THE REQUIRED SIZE OF THE SOIL HBSDR SYSTEM IS: �7 YL21 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRHINFIELD. THE DEPTH OF H TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). l"K&ulwk.j 1: X K0 154p4p, 131 421KEE... "r hi CA < 12: :E PA K F> K C_ F :.I(: (Di Fq K EE �����FR K E_:�, BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN 8 WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR H PRIVATE WELL OR 200 FEET FOR H PUBLIC WELL. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. ���R w H 1 1" L 1 IE::::,, 0-- PA FE Ne EE FA Ff I" Fwi!! 'C.H 11 �S�1�; 11 j �-7.-.: I CERTIFY THAI 1: I HM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. ]: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN ] BEDROOMS. SIGNEP: ISSUED B / Y URLAI LI( /11Vl,IRAMM:. hCL/\ EADMUU11 Di rtment of ❑IvironmenLaI (lua1iL 3330 "C' Strect Anchorage, Alaska 9 03 !!/l" t1 SOILS �L/OC I'I;ROI,ATION 'I FST Performed al Dem repoion.. 7 T/ /L-'----1— --- Percolation test Pcrfor:1 Legal Description..- /N._ 3!�_._FGLS __¢07_�5:_�..;-'L1--------- This-- -- p g---------- es t Dep th Feet 1 - o S 2- 3 - Sc ` IV Ava 50' aOu 05�) q_ w 4M' L e N. s/Ha d LeNS&S ��lrvouT dpnAA 5- 13 - Slot, - w- e- - - 1A JAJ 71 ----------�° X13--- ---��-s"'-�------.�4_.GJ�_ --- ------ ----------- 1Q - ��� e TtoM a (pS)t Ae Was ground water encountered? A10 __ if yes, at what depth? No Bedl�ocll< heading I Date I Gross Time .; , —,S. 111 Net Time Depth to Water ------------ Net Drop Perforincd (iy:__.T<tb_ z_!< Certified [iy: ��i� - ��ate:__�(�_-/3-7( EQ -040 (6/74) 1A JAJ 71 ----------�° X13--- ---��-s"'-�------.�4_.GJ�_ --- ------ ----------- Percolation Percolation rate d__ 6 -Proposed installation: __ininuteS Seepage Pit Drain Field Depth of f,OPih1ENTS:A1�%�__,}�t4_.__e._.__._ Inlet Depth to bottom of pit or trench Perforincd (iy:__.T<tb_ z_!< Certified [iy: ��i� - ��ate:__�(�_-/3-7( EQ -040 (6/74) C) a) T VJ CD I- [�- O O CY) CY) W o LL M V CL CL �Q {.L O 2 V Z Q J � Q � U E cn U L� Z o � U •L /o/'� 06 V) L E O t:: > (/) 00 co O Q Q Q U) N U) CO ra) v ) O O N m U N O N ci N d' N M 0 C O c Q x w 0 0 0 1 ti N 1 N Q ' 1 Y J C) W U ca d ti 0 LO rn Q LO (U J O Lr) U U Q W 3: w CY) 0� 0� O Z W H d' C O Q) U In a) 0 ca c0 J (n ri I� X W m O U) "D (D O C: (T) N O U) U) O 0 N 00 r 0 E N Q m O N V m L- 0 O v) O c m � E CD E O O U U IZZIN O N CD N 00 ill co Q) ca U a) U c Al M. 0 0 0 0 m 1 +• ' n. �� L 4 CL O 3 � •C) u)V N L CO C ~ O ~CD ca (D U >` d c O O V 0CD C .N N iC N 0 C _a LO Q > >, o 4+ v C N Q T '> > -0 fq Q .U) C < U Q N ocn L0 a0) C/)c 0 3 0 ° O_ .N z Q U E +, N > i O O O O CL Q. CL N v v O C a) L X x c " (j M O to CD o 0 +, An 1 v� E C 'a . > O Q Q O O 2 (1) y L N u) v- O L > Q ++ O U IL o c in v) O (1) L� U CL a) Q _ Z < r^ VJ 0 U Q O N �+ CL H Q L a a a) X a) 06 U E O m a) c 00 o LL rW V � O Z U z Q LL O 1 U U) J � a) (D E U) _V �L Z U a) 06 U E O m a) c 00 LL I 0 U U) � Q Wl 11 c N 3 U a) i O N U G. C 0) L ❑ C U i O O O O CDL O (n C N Ca) O Q U c D E U O O O O U) tiU 0 ❑ a) a) a a)a) Q L > W ❑ O a) � U W ❑ ❑ o a o le ,� u LO > C ❑ Q O U L � H a) J Q � a 0) a) m 0 N j m N S - v Q O 0LL — �, 0) >, �, 0 0 a-_ > N U)QLU a� o ElU N o CL CL M w U V m (BEl El Q p MI L .> M U) U i U) �+ a a ►- w E o W O LL ®❑❑ .- z qW Cl } p ❑ N Q ❑ _ O o a w U) U P: U, N ❑p tv 4- Q a cNLU dN p LO w U ao w : H cja� Z O Q � Q Q Z W o ? U J O U)Q Oz U) Q a) — 0- W LL W F– (� H — C: O �—W U a a) m W Z O L a E m N v) W E' N O W C� c6 O O I- D Z a } a } W CA CO a) 'O Q i a U U O (n Q Q > C> n r" cV M a L6 co W m 0 LL I 0 COSA Checklist.docx COSA Checklist Legal Description: T12N R3W SEC 15 LOT 56 Parcel ID: 015-052-27 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled CIRCA 1975 Total depth *230 ft Cased to *40+ ft (ASSUMED) Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) 12+ in. Date of flow test for COSA 4/29/2024 Static water level at beginning of test 127 ft. Well production at time of test 4.5 gpm Water storage tank volume NA gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate 0.612 mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date 4/23/24 Comments *Depths assumed per MOA record documents. B. TANK DATA Measured operating fluid level in septic tank 48” Date of pumping 4/26/2024 Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) *CIRCA 2004 ALL standpipes present per record drawing Total measured depth from existing grade 17.8 ft (max) Measured depth to pipe invert from grade 12.4 ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes (MT) go to bottom of effective. (ED) If not, state depth into effective 5.4’ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date 4/29/24 Results Pass Fluid depth prior to test 51 in Water added 650 gal New fluid depth 63 in Elapsed time 1440 min Final fluid depth 50 in (Missing 1” of ED) Absorption rate 450 gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) 66 in (MOA 5.5’ ED)* Effective depth used 51 in (Final Fluid Depth + Missing ED) Effective depth (ED) remaining 15 in Comments/Deficiencies: Approximate total measured depths from existing grade. ED per elevation measured shots & appears approximate 0.1’ or 1” of ED is not measurable per PES documentation. *This is a very deep absorption system that was recently documented by Pannone Engineering Services (PES). System is operating in the top portion of the ED. COSA Checklist.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 8/26/2024 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 8/26//24 -cl, r` 0 0) Cl) m t\ � ru M M M M � X O M LL �LLI V a I.i O 2 V Z a J aZ C a w � 5; u V F -CC N z o3 N � r w 2 U � O F' C N C O tw Z L L w +�+ � m 'E a � � O aj E w N 3 LU N3: O 0 ro > O L Q Q ci +-j N T Ln 4 M L a ~ t Q N r0 co Ov1 L O O 0O O co L c O 0 O Lr) O N 4-J ro (U OO rlj r -I N V) 0 ro 0ro L CL CL Q N Eu a N >, a +, N L L- p -: U o m Lr) m Z0 tko ro a ro QJ O ro >- O .N >` La a o Q- a-' L a rp N N u }' a a L _u Q L C o rl4w N Y ro 4. N L o Ln QJ J 1 bA 4- Q a O � % L N en E a a a U N a p a Q o c v O +, a u ro O rq C: +� a Ln oA a 7 O ai ro 41 ci U O M '0 -0 cn +co' Q N a H N aa+ N a CD OO v _0ON C 4- C > m N H ro > O L Q Q ci +-j N T Ln // / // / // / // / // / // / // / ///X X X X X X X X X X X X X X X X OH E OH E OH E OH E OH E OH E 50'50' 50'50' WORK ORDER No:DATE:SCALE: DRAWN: CB CHECKED: ME/RL ZONING: 1"=50'Apr 26,2024 R6 GRID No:FB BOOK/PAGE: SW2436 167/59 SURVEY CERTIFICATION: FARPOINT has conducted a physical survey of the subject property, the improvements situated thereon are within the property lines as shown. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the Plat used for this survey. NOTE: Under no circumstances should any data hereon be used for construction or for the establishing of property lines. PREPARED FOR: Earl Ford ASBUILT SURVEY OF: BLM Lot 56, T12N R3W Section 15, Anchorage, Alaska Found Rebar Cleanout Well Elec Meter Farpoint Land Services, LLC SURVEYING, MAPPING, LAND PLANNING, GIS 1131 E. 76th Ave., Suite 101 Anchorage, Alaska 99518 FarpointAK.com (907) 522-7770 survey@farpointak.com Robert O. Lumpkin No. 10459 R E GIST EREDPROFESSIO N A L L A N D S URVEYOR SERVI N G A L A SKA SI N C E 1 9 8 2 1.Bearings and distances derived from recorded plats unless otherwise noted. 2.Not all monumentation for this survey may be shown on this document. 3.Excepting for gross negligence, the liability for this survey shall not exceed the cost of preparing this survey. Found Almon Gas Meter Power Pole 4/26/24 F,l.UvJI( Wid,.I I OF AVICI;OtI A (Cjl- EWPAl" I 9rh-1_I OF t-ILAL I H AND ENVIH )N VIFft! MAL W O i Mtis" ITIvlSION OF: LPdt IRONMCi[elIM.!1P.M.;I CER (1IFICATC Of INSPF_CI ON 1-011 HLACH I FUJI HOHI I'( APPROVAL OL ON SII1.SLWLRANI) VIA ILHFACILITY MOM Applicaiion Date 1. 16E NEI1P.f_ 1 N O'ttl1l1['. (l0jr'! (a) Legal Doscnption (Include lot, block, subdlvisimi, section, township, range] 1 ,11 i.. t Location (address or dirociions) 0q Apoico t Name "' ,._t. �5 ___ _ telephona Horne C ".- I usiness ApMwmt AdWu;s (c) Appdcant,s (chock one)_ Lending Institution CI Oviner owwor (1.; w yei I I ; 00wi L. (e; nlwrl); (d)-iclophonc Adurosc _.,. 1. .'_:-_ t"tic (u many and Agenl --E .K_ Aa ( s [I) FViail the HAA tt; the follewrgg MUMS Number of Bedrooms Individual Well HI Community LI Public (_") Note: If communitywolf system, must havewritten confirmation from T ile S1=1eDepai wni o1 Fiiviwnmenttl Conservation attesting to the legality and status. }•EV°JAG[. DIISPOSAL Onsite U Public ❑ Community Ll Holding lank CJ Note- If community welt system, must have written confirmation from the Shho Doparlmont of L_nvu onmental Conservation attesting to the legality and status. Page 1 of 2 5_ fctVC3INi_(:RiNG Fif,SrP PfiC�'l/I(Jib..� IfJS{'pC:7lC)f�'., I'E.(S, FI!f� S"clilzC!-i, UF�.f f1 (1f=JL INP�_1fl'PfIA TION As certified by my seal affixed Hereto and as of the validation elate shovju hclow, I verify that my investigation of this Health Authority Approval shows Ihat rainon-site water supply and Or d;sposal system is safe, functional and ade(juate for the nurnber of bedrooms and type of structure indicated hNun I further vet dy that based on the information obtaurnrI from the Municipafty of Anchorage files and from my investigation and ingxChon, the on-site water supply anchor wastewator disposal systmn is in conipliance with all Municipal and State codes, ordinances, and reyulatlons in effect on Me date of this inspecOon. i Namcofl=irm_.,'•'re-_._Telephone Adore. HN k- -- - < <:_; _>:> 'A Date / :-:. alible Cl t< Sol l/ i\ppro I^c ror b:,droonts by - --/' - ` , _ . Daly • -.' : _ ---- ---- Approved _ —. __.__ 'unapproved _ __- _-- _- conditional -i-cans of C•oncin diel Approv;a CAN! 4 tl'r'd The MuncipaIdy of Anchorage Department of Health and Environmental MateAhn 0 Ali 11) issues Health Authority Approval certificates based solely upon the representations given in paragrMA 5 above by an Independent professional engineer regimored In Me SW of Alaska. The DFiEP does this as a courtesy to purchasers of homes and their lending Institutions in order to satisfy certain federal and stefo requirements. Dnployoes of )HEP do hat conduct inspections or analyze data before a certificate is issuod. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 "ME 0101) MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE (MOA, DEPT, Pa ENVIP.ONMENTAI. PRO"rECTIUN HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 ), O �gs� 264-4720 Legal Description: A. WELL DATA Well Classification ?rida�d 2P� iG�P��cC if A, B, C, D.E.C. Approved (Y/N) Well Log Present (Y/N) - N D to C mpl t , -- — Yield ts 5 c7pin Total Depth - 3 Cased to --- D th of Grouting / Static Water Level`r " na w-" more A64 50 / Pump Set At — G�ry���z"'�� � Jre LI Casing Height Above Ground —\//� — Sanitary Seal on Casing (Y/N) — Electrical Wiring in Conduit (Y/N) Depression Around Wellhead (Y/N) _ K10 Separation Distances from Well: To Septic/Holding Tank on Lot —_ oo On Adjoining Lots �jN/A I To Nearest Edge of Absorption Field on Lot _L("L9 ;On Adjoining Lots To Nearest Public Sewer Line .— WA To Nearest Public Sewer Cleanout/Manhole WA -- To Nearest Sewer Service Line on Lot 0 -- Water Sample Collected by _4,�kV l P�� z-1 /-� ; Date Water Sample Test Results Comments My B. SEPTIC/HOLDING TANK DATA 6ri i?- Date Installed b9 7(o Size _A�5o C�a"_ No. of Compartments _-- — Standpipes (Y/N) _ Y — Air -tight Caps (Y/N) �{ Foundation Cleanout (Y/N) —ytf-% S Depression over Tank (Y/N) —� Date Last Pumped, Pumping/Maintenance Contract on File (Y/N) Holding Tank High -Water Alarm (Y/N) _ Temporary Holding Tank Permit (Y/N) ;for Separation Distances from Septic/Holding Tank: To Water -Supply Well - To Building Foundation I To Property Line _ 1 To Disposal Field To Water Main/Service Line Course -- Comments _—— Page 1 of 2 72-026(11/94)- 3SI To Stream, Pond, Lake, or Major Drainage C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata ��V S0 Type of System Design 'I ng"Ck Date Installed /ri�7/P / / Length of Field �� Width of Field / Depth of Field 7/ ✓d/ / Gravel Bed Thickness & Square Feet of Absorption Area Standpipes Present (Y/N) y�5 Depression over Field (Y/N) P' -C2 Date of Last Adequacy Test Results of Last Adequacy Test 4X_llewl /Zd0 %-p/ 4 7 /lig• Separation Distance from Absorption Field: To Water -Supply Well )OGI To Property Line ?til To Building Foundation bsl To Existing or Abandoned System on Lot To Water Main/Service Line To Stream/Pond/Lake/or Major Drainage Course _ To Driveway, Parking Area, or Vehicle Storage Area Comments i$ a/'/� R' iclie efl D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at _ Tested for Electrical Codes (Y/N) Comments On Adjoining Lots IVF/F To Cutbank (if present) U/A Dimensions Manhole/Access (Y/N) "Pump Off" Level at — Vent(Y/N) Pumping Cycles during Adequacy Test. Meets MOA ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verifi or conformed to all MO/A a/qd HAA guidelines in effect on the date of this inspection. SignedC Date Company �� 4vt P 5",9 , MOA No. Receipt No. S9 q,43Q Date of Payment (o –�� Amount: $ 6 rva�l etC OF 4/ Wineer's Seal Page 2 of 2 72-026 (11/84) F. Charles Kel CE 6211 I0� SU IDT Jto GRE7ATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received _October 14, 1976 - Time of Inspection �%, 3 4(d - Date of Inspection REQUEST FOR APPROVAL 01 INDIVIDUAL SEWER & WATER FACILITIES FOR V. A. 1. Approval requested by: Coast Mortgage Company Mailing Address: Post office sox 7.200 --_ Phone: 279•-0665 -- 2. Property Owner: Herman R. Martin --- Phone: 344•-3G05 _- Mailing Address: 9441 Abbott Loop Road ---------_ 3. Legal Description: T12N R3W Section 15 Lot 56 --- --- 4. Location: 9441 Abbott Loop Road 5. Type of facility to be inspected single Family — No. of bedrooms 3 —_ 6. Well Data: Individual A. Type -- —_ B. Depth, ---- C. Construction ---_ D. Bacterial Analysis — —_ 7. Sewage Disposal System: Onsite system (i,pz,p,a,&71 190G) A. Installed _ 1975 —_ B. Installer C. Septic Tank: 1. Size —_ 2. Manufacturer _ D. Seepage Pit: 1. Absorption Area _ 2. Material E. Disposal Field: Total 'length of lines ----- 8. Distances: A. Well to: Septic tank _--_, Absorption area Sewer Lines Nearest lot line _--> Other contamination B. Foundation to septic tank _--_, Absorption area —_--+ C. Absorption area to nearest lot line EQ -034 (1/74) Page 1 of two pages Page 2 of two pages - Re st for Approval of Individual `' er & Water Facilities Legal Description T12N R3W Section 15 Lot 56 -- --- Comments --- -- �._ Approved (z _ Disapproved _ ----- Date 1OL�� -7 Approval ,Valid for one year from date signed Greater Anchorage Area Borough, Department: of Environmental Quality DIAGRAM OF SYSTEM accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED _— Date EQ -034 (1/74) UANOU&NIC:( ASTUNa_1.1 �.K KP_i August 14, 1986 L.C. Kenley, Y.L. 715 L Street, Suite 1 Anchorage, Alaska 99502 Subject: TUN 83W Section 15 Lot 56 Waiver Reuqest, WR86-015 Dear Mr. Kenley: Your request for a waiver of the 100 foot separation required between the septic tank and well on the subject property has been „ranted. This distance has been waived to 80 feet. This waiver is valid for the existing three bedroom single _Family dwelling only. Sincerely, 7 � Stephen S. Morris Civil_ Engineer On -sine Services SSM/ljw F. C. KENLEY ASSOCIATES CONSULTING ENGINEERS 715 L Street:, ;quite 1 Ariahorage,, Alaska 99501 (907) 276-3111 July 24, 1986 Mr. Earl Ford I ( % l 3w 9441 Abbott Loop Road Anchorage, Alaska Re: Adequacy Test for On -Site Sewage Disposal system. 9441 Abbott Loop Road Mr. Ford : Please submit this letter to the Municipality of Anchorage Department of Health and Environmental Protection as evidence that we concur with a previous waiver that: was granted by the Municipality for the on-site disposal system at the above mentioned address. The previous waiver which the Department has a copy of, allowed the septic tank to be less than the required distance from the single ;Family well. The actual distance is about 88 feet. We offer the following justification for the waiver. 1. The septic tank is in good condition and is operating properly. 2. The ground water table is not near 'the surface, as shown by the well static water level, thus there is less danger of contamination. 3. The soile in the area will provide for a medium rate of percolation. There is no evidence of poorly graded gravels with little or no fines that would allow rapid percolation of 'the waste water. For these reasons we recommend Please let us know if there is assistance with. Respectfully, 6251 ^� 1 that the waiver be continued. anything further that you need MUNICIPALITY Of ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION FJUL 2 4198E RECEIVED