Loading...
HomeMy WebLinkAboutT12N R3W SEC 15 LT 111 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241383 Work Type: Septic Upgrade Tax Code Number: 01548305000 Site Legal Address: T12N R3W SEC 15 LT 111 G:2536 Site Mailing Address: 10100 OUR RD, Anchorage Owner: METROKIN DENNIS W & Design Engineer: FIRST WATER CONSULTING This permit is for the construction of: Effective Date: Expiration Date: y„t�t�r �J 01, f� ('1 r -.., t)<l�rtttte�ttt Lot Size in Sq Ft: Total Bedrooms: 11 /26/2024 11 /26/2025 37950 2 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 4 Received By:'7_0 L✓ (- Date: Issued By: Date: ON -SITE SEPTICIWELL PERMIT APPLICATION Parcel I.D. 015-483-05 Property owner(s) METROKIN DENNIS & ERNESTINE Day phone Mailinq address 10100 OUR ROAD, ANCHORAGE, ALASKA 99516 Site address 10100 OUR ROAD, ANCHORAGE, ALASKA 99516 Legal description (Sub'd., Block & Lot) T1 2N R3W SEC 15 LOT 111 Legal description (Township, Range & Section) Lot Size 37,950 Sq. Ft. Number of Bedrooms M APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (Z all that apply) Absorption Field E& Initial 0 Single Family (SF) Gi (w/wo, ADU) Septic Tank ER Upgrade Gi Duplex (D) M Holding Tank El Renewal F] Multiple Dwellings ❑ Privy D (SF and/or D) Private Well D Water Storage M THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Sig natu're'of:'p'e6berty owner or authorized agent) Permit/Rush Fees: 015q5- Date of Payment: I Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / FirstWaterAK@gmail.com ! !! November 20, 2024 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC SYSTEM UPGRADE PERMIT LEGAL: T12N R3W SEC 15 LOT 111 – (10100 OUR ROAD, ANCHORAGE) The property owner has requested we obtain a permit to upgrade the failed septic system of the above referenced lot. We propose to install one deep trench and a 1500-gallon deep-burial septic tank to serve the existing 3 -bedroom residence with an existing 4-bedroom septic system. The design is based on the recent test hole conducted on November 8, 2024. No groundwater was observed at test hole excavation or monitoring. The proposed trench is to be installed as high as possible on the slope as designed. All biomat material of the existing absorption field within 18’ of the proposed trench will be removed and replaced with insitu GM/sm soils or MOA sand. The slopes are 13 -18% at the proposed upgrade location. The lot and area are served by private water. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241383, Curtis Townsend, 11/26/24 3B R HO U S E LOT 111 SHED CA N T. DECK ASPHALT DRIVEWAY UTILITY PEDESTALS GRAVE L D RIVEWA Y OU R RO A D REBAR REBAR W/CAP WELL N 0 0 ° 0 6 ' 1 5" W 3 3 0. 1 3 ' S 0 0 °0 6 ' 0 0 " E 3 3 0 . 0 7 ' N 90°00'00" E 165.01' LOT 110 LOT 1A-2 GAZEBO 50' 50' 40 . 0' 28.0' 21 .0 ' 4.0'5. 0 ' 12.0' 24 .0 ' 44.0'---21.5'--- ---99.4'--- VACANT LOT 2 LOT 1 LOT 3 WELL APPORX. LOC. WELL APPORX. LOC. FIRST WATER CONSULTING T12N R3W SEC 15 LOT 111 DESIGN CALCS: NO WELLS WITHIN 100' OF PROPOSED SEPTIC SYSTEM Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241383, Curtis Townsend, 11/26/24 3B R HO U S E LOT 111 CA N T . DECK ASPHALT DRIVEWAY GRAVE L D R I V E W A Y WELL N 0 0 ° 0 6 ' 1 5 " W 3 3 0 . 1 3 ' LOT 110 GAZEBO 40 . 0' 28.0' 21 . 0 ' 4.0'5. 0 ' 12.0' 24 . 0 ' ---99.4'--- FIRST WATER CONSULTING T12N R3W SEC 15 LOT 111 DESIGN DETAILS: Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241383, Curtis Townsend, 11/26/24 13030 Sues Way - Anchorage, Alaska 99516 Tel. 907-350-9566 FirstWaterAK@gmail.com SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: T12N R3W SEC15 LOT 111 – 10100 OUR ROAD OFF O’MALLEY PERFORMED BY: FWCS / FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 11/15/24 DEPTH FEET OG SOILS 1 ORG/OL 2 3 4 5 6 7 8 GM/sm 9 10 11 12 13 14 15 16 17 BOH 18 19 20 Reading Date Gross Time Net Time Depth to Water Net Drop 11/09/24 30 min 6” 3 2/16” 30 min 6” 3 2/16” 30 min 6” 3 2/16” PERCOLATION RATE 9.6 (MIN / INCH) TEST RUN BEWTWEEN 5 & 6 FT PERC HOLE DIAMETER 6” PRE-SOAKED PRIOR TO TEST & ALL READINGS TO THE 1/16TH. GROUND WATER ENCOUNTERED: NO IF YES, AT WHAT DEPTH: NA DEPTH TO WATER AT MONITORING: DRY DATE: 11/15/2024 TESTHOLE # 24-1 DATE PERFORMED: 11/8/2024 SEE SITE PLAN FOR SLOPE & LOCATION COMMENTS: VERIFY GROUNDWATER MT AT TIME OF CONSTRUCTION PERFORMED FOR: DENNIS & ERNESTINE METROKIN 11/15/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241383, Curtis Townsend, 11/26/24 LOT 1A-2 N 90000'00" E 165.01' UTILITY REBAR PEDESTALS I LOT 111 54,470 sq. ft 2-STORY SHED FRAME HOUSE 21.5' 44.0' D N z ,p 4.0'�„ A O � 12.0' o_ 28.0' z _ CD O DECK 0 CD (7) LOT 110 SEPTIC STANDPIPES w W O W WELL vE�OR\V��P� G� I I GAZEBO -0- 50' ROADWAYAND UTILITY RIGHT-OF-WAY REBAR W/CAP ASPHALT DRIVEWAY 50' 0 O 0') O O C O �13 70 m o w � W O O v *: 49 rH ................ ............ N 90000'00" W 165.00' 2o�z6�2� .................., i B u Saliz : _�o r LOT 112 j s� LS-14837 J fit F� 0 20' 40' EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED SUBDIVISION PLATAND PATENTARE NOT SHOWN HEREON. THIS DOCUMENT DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE USED FOR CONSTRUCTION OF FENCES, IMPROVEMENTS, OR FOR ESTABLISHING PROPERTY BOUNDARIES. AS -BUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: GOVERNMENT LOT 111, SECTION 15, TOWNSHIP 12 NORTH, RANGE 3 WEST, SEWERD MERIDIAN ANCHORAGE RECORDING DISTRICT, ALASKAAND THAT THE IMPROVEMENTS AS DEPICTED HEREON EXIST AS SHOWN IN RELATION TO THE PROPERTY LINES. DATED THIS 14th DAY OF OCTOBER, 2024, AT ANCHORAGE,ALASKA. FIXED HEIGHT, LLC C.O.A.122554 Land Surveying Services WWW.FIXEDHEIGHT.COM 600 W 41 st. Ave, Ste. C, Anchorage, AK 99503 907.290.8949 JOB # 24248 NO CORNERS SET THIS DATE I SCALE 1" = 40' ,,~--~O~,y~,,~,,,~,,~..,~,~ MU NI CI PA LI TYOF ANCHO RAGE DEPARTMENT OF HEAl.TH & ENVIRONMENTAl. PROTECTION ~ ENVIRONMENTAl. ENGINEERING DIVISION 825 L Street - Anchorage, A as (a 99501 Telepl~one 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WEI.L INSPECTION REPORT NAME ...................................................... PHONE ~EW MAILING ADDRESS Po ~,z /o.-3~'7 LEGAL DESCRIPTION LO A ,O DISTANCE TO:I~DO ~/ t~/ No. of lines / Top of tile to firdsh gra( e / Length Width Total length of I'nes Material beneath tile Depth Type of crib Crib diameter Cdb depth Well DISTANCE TO: PERM,T NO. ~? O i No. of compartments Total effectiveabsorpti n area PERMIT NO. Total effective absorption area Building foundation Nearest lot line Distance to : line DISTANCE TO: OTHER PIPE MATERIALS SOIL TEST RATING ' INSTALLER REMARKS PFRMIT NO. IAbSorption area(s) APPROVED DATE LEGAL I 1"HE [.!:N[}~i'H E',;EHEN;::;T. ON ;I;¢~; 'tHEE L. ENG'i'H C ;EN FqEE-f II'-ll:Z DE;!:::'t'H L)F F:i TI::EF,IE:Fi orr f;:';[ I" J;:!.:.; FHE: DZ:5'r'Fli'.,!E:!:.; (!il:;;%ll.l?-,JE:, F:ff.!E:, 'l"J.l[!; E',EFt'f'Ot',~ OF' q"!-.1E; 1~;:4CI::f,,,'FFt'ZEd'.,I ,:;];I'.4 'FF'IF:: GRFI',,,'EL J::,ii~:f:"Jl~l :[:.'; !"HE J"l:[ht:[I"fl~ll"t I::'EI::"t'H Ell::' F!HD FI'IE ii?.EI¥!'E~H Ed::' 'THE- EXCI:::f,,,'I:IT[Ed'.4 ,::)ZN !::'iEE'I"? [::,I .iF;;: ]: NJ3 THE: "FILE: I'"! ]: !'-,t I_ HI .tt'"J I) ['_:;:'! FtNCEZ Ei~E"J'!,.ti;{t:~('t F:I t,.fE:LJ_. FIN[:', t::tN"r' EtI',!--.':_:;:ETE 'iil;tif:[,lf::l(]iE: ::U:'3EI F'EE'T' I:::0[;: FI F'F::];","FI'¢!:: I'!ELL O1::;: :j_~;i~:l 'l'O ;2EIEt I:::'EE:I" F'F:OH F:I F'LIE',L];E: HELL E:'IEPIZN!)[hIEi IJF'OI"~ THE 7"¢F'E OF' F'I..tE:t..).C H:[N.[HI..th! [::';I:'E;'iF!NCE F'F;:OH I:;l F'F:~:","FIT'E: !,.IiEL.I. -FEi FI F'I:;:[",,'FI"i'E :5i:!,t[:;F:: L]:NE: I:~:~; ;;~::~ F:E:t~}:~' F:IF.IC, "FO FI CO!"!HU!"~:[T'r' ':;E:HE.I:;;: L]:I"~E ]:E; ';:"~5 FEET t,.!I.~!.L t_[)G~; FtF:E: F:I:E(:iI.i:[F;:I:~%, FINI::' I'llJ'.~:~' E:F.': ~rE:TU[(:!",IEI) TO THE: DE:F'I::t~:T'[fiEN'F ElF 't't'1~ tqEEL.L.. Ci3HF'LE:T':[Eff.,1. O'FFtEF;: F~:I:E[:!LI :[ f4:EHEN"t :~; r, tFl? FfF'F'I .?. 'sr:'EC ~ F' ]; Cl::f'¢ [ Ed'.}~; F!NI:::, COH:ET! !::I*,:,'FI ;[ L.t::II:ILI: "f'(3 [ J'.,i~;!..l~;i:~: F'f;;:I::)PI]{I:;~: :[ J'.l:~; J"F:II .L FI-I ); E;i'.,IL.F:!I:~:(:iii:H~:{N'r iZ F: 'i'HE: ~;~:-?'"~'~:'""('_~U'JV'~ "C~:¢' - MUNICIPALITY OF ANCHORAGE ~:~. ,. - ....,~, ~ LEGAL DESCRIPTION: ~/¢'YJ//~ ,-~:'~'~: /~"~ .~4~',"'~ ,~° 3Y~y ~'~,d,~',~ ~;~¢~, ~,~,~ ~.,~. SLOPE WAS GROUND WATER ENCOUN'FERED? _'~ P E IF YES, AT WHAT DEPTH? / SITE PLAN 9- 12 19 20 Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (907) 243-7893 KEN JOHNSON WATER WELL DRILLING PUMP SALES & SERVICE 3163 LINDEN DRIVE ANCHORAGE, ALASKA 99502 tvb~Y 2~, 1982 P & P PRUDUCTIORS Larry H. Neas OUR RO~D ~NCHORAGE, REI 'dater well Lot ~21 Sect° 1~ T 12 N R3W Slvl WATER WELL LOG Frozen brown Course gray and bt, own silt Corse gr. ava %r~y silt ( tight ) ~,ied. gray and bro~a'~ silt Sand & brn silt weeps 8'..dj. try Sandy brown silt Sand.. H2o.. Heaves 5'.. 15' head,.dir'ty Sand & brn silt Clean course f~ravel and ~and wa~er bearing 52 ft static water level Test bailed at 1~ No drawdown Clearing rapidly MUNICIPALITY OF ANCHORAGE DIVISION OF ENVIRONMEbr£AL HEA3~TH DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE General Information (a) Legal Description (include lot, block, subdivision, section, tovmship, range) Location (address or directions) (b) Applicants Name~ ..... Tele~J!pne - Home Business Applicants Address (f) biail the HAA to the follovrlng address: l.T.~i[p.~2 f Residence Single-Family I~[ Number of Bedrooms Wa~t e r~S=upp ~y Individual Well ~ Multi-Family E~ Other (describe) Community ~__~. Public [~[ Note: If community well system, must have written cenfirmation from the State Department of Environmental Conservation attesting to the legality and status~ 4. ~osal Onsite ~ Public ~ Community [~ Holding Tank Note: If community well system, must have written confim~ation from the State Department of Environmental Conservation attesting to the legality and status. [Page 1 of 2] 5. E__n~i. neerinfu_Firm Providing Inspections. Tests- File Search ~ -~ .z~--~_u.z ......... ~_.~_~ and Info~rma~tio~n As certified by my seal affixed hereto and as ot! the validation date shown below~ I verify that'. ~y investigation of this Health Authority Approval shows that the on-site water supply and/or wastewatar disposal system is safe, functienal and adequate for the number of bedrooms and type of structure indicated herein.- I further verify that~ based on the information obtained from the Municipality of Anchorage file~ and from my investigation and inspection, the on-.site water supply and/or ~¢as~ewater disposal system is in compliance ~rlth all Municipal and State codes, ordinances, a~ regula-~ tions in effect on the date of this inspection° Approved for ~?>//~_ bedrooms Approved >~_ Disapproved Terms of Conditional Approval ........ Telephone CAUTION THE MUNICIPALITY OF ANCHORAGE I~']PARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION (DHEP) ]iSSUES HEALTH AlYfHORITY APPROVAL 6%RTIFICATES BASED SOLELY UPON T~IE ILEPRESENT~ ATIONS GIVEN IN PARAGI~kPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF ALASKA° THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE- MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A CERTIFICATE IS ISSUED° THE MUNICIPALII~f OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK. (DHEP SEAL) RR4/eJ/DI8 [Page 2 of 2] 7-19-84 ae WELL DATA MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 Legal Description: Well Classification Well Leg Present (_Y/N) Total Dapt~... ~ 7 Cased to ~' Static Water Level ..~ ~ Casing I~ight A~ G~nd Elee~ical Wi~ing in ~nduit !~) ~p~ation Distends ~ ~11: To ~ptie~olding Ta~ ~ ~t I01' To ~a~st ~ge of ~so~ption Field on Lot ~' _ To Ne~sst ~blie ~ Line _ Pump Set At · Depth of Grouting Sanitary Seal on Casing (Y/N) Depression A~ound Wellhead _(Y/N) C].eancut/Manhole_ 61./L To Ne~est Sewe~ Service Line on Lot Wate~ Sample Collected Bi; '/'/=~/~ ; Date Water Sample Test Results Co~t~(~nts ; On Adjoining Lots ; (An Adjoining Lots__~.~oo ' To Nearest Publi~ Sewe~ ~,,4, B. .S.E. PTIC/HOLDING TANK DATA Date Installed '~/~/~ ~_ Si?~ 1 9_~'~ No. of CQ,~a~tm~nts Standpipes .(.~/N) ~ Air-tight Caps (Y/N) ~' Foundation Cleanout (Y/N) Depression over Tark (Y/N) N __ Date Last P[mt~ed 5'/E ! /~ Pumping/Maintenanos Contract on File (Y/N) ~l,/~. ! for ~,~. Holding Tank High-Wate~ Alarm (Y/N) N,~', %%mt~Dra~y Holdirx3 Tank Permit .(Y/N) Separation Distances f~.cm Septic/Holding Tank: To Water-Supply Well ~ To Building Foundation ~ ' To Property Line _ ~-~ Iff ' To Disl~Dsal Field To Water Main/Servic~ Lir~ . Course _~ ~, To Stream, Pond, Lake, c~ Majo~ D~.ainage Comments [Page 1 of 2] Receipt :~ Date Paid: 2-15-84 C. ABSORPTION FIELD DATA Soils l~ating in Absorption Strata Date Installed 7 ./_~; /~ ~ Width of Field ~" Square Feet of Absorption Area Depression over Field (Y/N) Results of Last Adequacy Test ~'7~' m'/l~r,~ Type of System Eesign Length of Field ?8' Depth of Field 6 ~/z Gravel Bed Thickness _ ~ ~ Standpipes Present (Y/N) Date of Last Adequacy Test Separation Distance from A~sorption Field: To Water-Supply Wall ~6; 3 To Property Line -~ To Building Foundation 3 ~' To Existing or Abandoned System cn Lot N~. ; On Adjoining Lots ~ To Water Main/Be~vice Line ~,~. To Cutbank(if present) To Stream/Pond/Lake/ct Major D~ainage Course ~, To Driveway, Parking Area, c~ Vehicle Storage Area ~' CcmTents D, LIFT STATION Date Installed Size in Gallons "Pump Oa" Level at High Water Alarm Level at Tested for Electrical Codes(Y/N) Comrents Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA ** Check Permitted Bedroom Rating Against HAA Request I certify that I have checked, verified, or conformed to all MOA HAA Guidelines in effect on the date of this inspection. [Page 2 of 2] · '~=R ' ~' - 2-15-84 APPLIC , IT FILLS OUT UPPER HAL ONLY Address Zip Code Lending Institution Phone Address Zip Code ~treet Locati~ f-'~ ( ) ~ 0~ ~. Type of Resl~nce ~gle Family Water S~pply ~divldual WELL LOG, A well is for all wags since June 1975. ATTACH log driJled ~ Community For wells drilled prior to that date, give well depth (altech IoW'if available). ~ Public Ulility Sewer D~sposal blic Year Individual Installed: , Utility When Connecled to Public Utility: NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST REFORE ~OCESSING CAN BE INITIATED. Time Time Time Date Date Date Inspector Inspector Inspector Field Notes: .f~) Time /4/ ) APPROVED BEDROOMS ) DISAPPROVED ) CONDITIONAL APPBOVAL' DATE ~'- ~//--' 'CONDITIONS OF APPROVAL Soils Rating Date~werlnstalled Well To Absorption Area Well to Tank Well Log Received Septic Tank Size Novembo.~; 23~ 1982 Subject: I,ot lll Sec, 15 T12H R3W Approval for the (nd:iv(dual ,qcnmr and wa/et~ ..t(.~.li'hies cannot ~)e JLdnt. cd II,Ifil tho. fei. lowing :Ltenh~-3 have beeY~ completed~ £h~ top of tho well water tiqht. ,<~,,~L (hu~l)idi. ty). The well should be f. lushec'l clear by turning Please notify this Depar.tm(Hlt ~o~? a reinspoction when the ~loted f]i.~c're...~}anci[~s have J3(!e~ correct(HI, .[f ~['lere arq any " O~.L further qttestions, })lease (.all this '~ :ice at 264-4720. ricer.(..J.y ~ RP 2 3 3 /p/l.::[I Robert. C. Pratt A;mociahe l,nvit~on(lenhL1 S ~',cJal Jst