ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP191526 . PID Number: 015-482-04
Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑N Upgrade
Name
Foxstinbaugh Living Trust
ABSORPTION FIELD
❑ Deep Trench A Wide Trench ❑ Bed ❑ Mound
Site Address
10230 Carlson Rd. Anchorage, AK 99507
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
242-8117
3
0.6 GPD/SF
9.5 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
5.0 Ft.
Gravel depth beneath pipe
4.5 Ft.
Subdivision Block Lot
124
Fill added above original grade
1.15 Ft.
Gravel length
78 Ft.
Township Range Section
12N 3W 15
Gravel width
5.0 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
780 Ft i
1
Ft.
Well
N/A
>1 00'
N/A
N/A
>25
TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Existing
Capacity
Gal.
Surface Water
N/A
>100'
N/A
N/A
Material
Number of compartments
Lot Line
N/A
> 10'
N/A
N/A
NA
Foundation
N/A
>10'
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Remarks
Gal.
Alarm location
Electrical installed by
PIPE MATERIAL House to tank Exist. Tank to
drainfield D3034
Installer
Denali Excavating
Drainfield D3034 CO/MT D3034
Inspector J. Williams
BENCH MARK (Assumed elevation) 100 ft
Inspection
1s` 12/21/19
Location and description
dates: 2�e
Threshold of back door.
3rd 4,h
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
Conditional Approval: Date
�"OF"'..qS��i
' 49th ♦�
7''v� C �ZZZ"T i
i .I............ ,
�f� ��•.�MICHAEL E. ANDERSON t�e
Septic System
r—
Approve - Date — Zo 2
♦ �� �, N o. CE -4381 �'' _=
%.. 1/10/20
Note: this does include
••o°•�c���
44 ;RO;;Sa;� �•s•
approval not well permit requirements.
kmuv UDiva i D/
T12N R3W SECTION 15, LOT 124
PERMIT # OSP191526 PID # 015-482-04
EAST 102ND AVENUE
EXISTING WELL \1
I
w i
LOT 125 3-BDRM HOME /
VACANT
\ / q
\ / Q
O
EXISTING ABSORPTION SYSTEM
PARTIALLY EXPOSED TO
ENSURE MINIMUM SEPARATION
OF 18' TO NEW TRENCH.
78' LONG x 5' WIDE x 4'
EFFECTIVE DEPTH
ABSORPTION TRENCH.
MAINTAIN 18' FROM /
EXISTING TRENCH. —/
/
i
i
EXISTING WELL
µ,E`_ ENGINEERING
49th •e. ��
'% It MICHAEL E. ANDERSON
�,p No. CE -4381
113120
%j°"ROFESS\ �'
Coe _ \
H#C�THffit ® MT7
TH- 81
LOT 424,\
10' UTILITY EASEMENT �—
LOT 131 1
PLAN AS -BUILT
0 50 100
ion ME �m FEET
V=50'
A B
FD 44.9 47.5
MT1
LL-
EXISTING
C01
z
SEPTIC TANK
MT2
O
FD
CO2
81.5
91.9
rill
2
, U
Coe _ \
H#C�THffit ® MT7
TH- 81
LOT 424,\
10' UTILITY EASEMENT �—
LOT 131 1
PLAN AS -BUILT
0 50 100
ion ME �m FEET
V=50'
A B
FD 44.9 47.5
MT1
102.9
92.65
C01
103.8
92.3
MT2
79.75
90.2
CO2
81.5
91.9
LEGEND
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FD - FLOW DIVERTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
T12N R3W SEC 15 LT 124
PERMIT # OSP191526
PID # 015-482-04
97.75 FINISH GRADE
Ove 96.6 ORIGINAL GRADE
91.6
DRAINFIE D, ROTSK•. ,
87.1 78' 87.1
NO GROUNDWATER 1/2/20
f
Trench only replaced under this permit.
PROFILE AS -BUILT
(NO SCALE)
91.6
SOILS LOG AND PERCOLATION TEST
ENGINEER 1 N G
LEGAL DESCRIPTION: T 12 N R 3 W SEC 15 L124
PERFORMEDFOR: FOXSTINEBAUGH TRUST
DATE: 12/21/19 PROJECT No.:
PARCEL ID#: 051-482-04 TECHNICIAN: J. WILLIAMS
DEPTH TEST HOLE #1
(feet)
1
2
3
4
5
6
7
8
9
1
11
12
13
14
15
16
17
18
19
2
OB
1 .
SANDY SILTY GRAVEL
GM
.f ..
SLOPE
SITE PLAN
SEE SITE PLAN figg,
�d
�' •
READING
WAS GROUND WATER ENCOUNTERED? NO
NET TIME
(MINUTES)
DEPTH To
WATER
(INCHES)
NET DROP
(INCHES)
rs
IF YES WHAT DEPTH? —
L
1
10:25
2
DEPTH OF WATER AFTER MONITORING: NONE
P
116
s
DATE OF MONITORING: I/2/20
11:00
01611
E
11:30
COMMENTS:
DATE
READING
GROSS TIME
(MINUTES)
NET TIME
(MINUTES)
DEPTH To
WATER
(INCHES)
NET DROP
(INCHES)
12/21
TEST HOLE PRESOAKED PRIOR TO TESTING:
1
10:25
016"
2
10:55
30
116
116"
3
11:00
01611
4
11:30
30
116"
116"
5
11:33
0161
6
12:03
30
116"
116"
PERCOLATION RATE: 24 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN: 4 FT. and 5 FT.
PO BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
December 16, 2019
MOA Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: T12N R3W Section 15, Lot 124 – 10230 Carlson Road
Septic System Design
Dear On-Site Services Engineer:
The absorption trench on the subject lot has failed and must be replaced before a COSA can be
issued for the property. We are submitting this permit application for the construction of a new
absorption trench to serve the three-bedroom home. The septic tank was replaced less than two
years ago. The attached site plan identifies the location of the home and the existing well and septic
system and the proposed trench location. No conflicts exist between this proposed system and any
other well or septic system on this lot or adjacent lots.
The ground surface on the lot is flat in the area of the proposed absorption trenches. There are no
slopes greater than 25% within 50 feet down slope of the proposed absorption trench. Drainage
arrows are shown on the site plan indicating the grade and direction of flow. Storm water drainage
will not impact this septic system. The new trench will be constructed parallel to the slope as much
as possible.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank.
Please refer to the attached test hole logs and plan and profile sheets for the septic design. If this
design is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Michael E. Anderson, PE
12/16/19
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191526, Deb Wockenfuss, 12/18/19
EXISTING WELL
10050 0
FEET
1"=50'
75' LONG x 5' WIDE x 4'
EFFECTIVE DEPTH
ABSORPTION TRENCH.
MAINTAIN 18' FROM
EXISTING TRENCH.
3-BDRM HOME
NOTE:
SLOPES >25% WITHIN 50', BUT ABSORPTION TRENCH CONSTRUCTION
MEETS THE DEEP SLOPE PROVISION. NO SURFACE WATER WITHIN
100' OF THE PROPOSED SEPTIC SYSTEM
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC
SYSTEMS.
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
T12N R3W SECTION 15, LOT 124
CARLSON ROAD12/17/19
10' UTILITY EASEMENT
EXISTING
SEPTIC TANK
ALTERNATE SITE
COMTEXISTING ABSORPTION SYSTEM.
EXACT LOCATION UNKNOWN.
LOCATE TRENCH AND MAINTAIN 18'
SEPARATION TO NEW TRENCH.
PROPOSED
TEST HOLE
CO
FD
EAST 102ND AVENUE
0
-
5%
0
-
5%
0
-
5%
0
-
5%
EXISTING WELL
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191526, Deb Wockenfuss, 12/18/19
T12N R3W SECTION 15, LOT 124
DESIGN FACTORS: SYSTEM REQUIREMENTS:
450 GPD PEAK FLOW
PERK RATE: 16-30 MIN/IN
APPLICATION RATE: .6 GPD/SF
5' WIDE TRENCH SYSTEM
EXISTING 1,250-GAL SEPTIC TANK
TYPICAL TRENCH SECTION
(NO SCALE)
4" PERFORATED PVC (HOLES DOWN)
DRAINFIELD ROCK
5'
6"
6"
3.5'
4'
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
BOTTOM OF TRENCH: 8.0' BELOW GRADE
FLOW LINE ELEVATION: 4.0' BELOW GRADE
TOP OF TRENCH: 0.5' ABOVE GRADE
450 GPD / .6 GPD/SF /5' WIDE * .5 (RED. FACTOR) = 75 LF TRENCH REQUIRED (75 LF SPECIFIED)
12/17/19
GEOTEXTILE FABRIC
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191526, Deb Wockenfuss, 12/18/19
Lot 98A _ _ Lot 99A Lot t 00A
E. 102nd AVENUE o
EAST 164.97'
n
/^ BLM
o / I
IF,
13.2'x11.6' S
DOG I
\12.2'02.0'
GREENHOUSE
w/ 4' DECK
WIRE FENCED GARDEN-
\ Z
\ e
Lot 125
W
C4
O
Lot 130
& R.O.W. RESERVATION
100' PROTECTIVE RADIU I
WELL
SEE HOUSE
DETAIL
SEPTIC
PIPES
Lot 124
54,455 S.F.
WEST 1
0
D
M
r
N
O
Z
Lot 123
' 2nd STORY ONL
— — —
4 --
50.0' 50.0'
Lot 131 I Lot 132
BLM UTILITY &
R.O.W. RESERVATIONS I
HOUSE DETAIL
Scale: 1" = 30'
2nd STORY ONLY
0
14.8' ml
C�L_____ DECK
74.2' o
24.0'
2 STORY
RESIDENCE
26.0' 16.4' 24.0'
20.0
DECK
PLOT PLAN AS BUILT _X_ SCALE _1" __60__ GRID __2k_25_36_ Project No.
11500 Daryl Avenue, Anchorage, Alaska 99515-3049
Lang & Associates, inc. (907) 522-6476 Phone 0000�ppp
(907) 522-4625 Fax oo F A p�4
Professional Land Surveyors kenOlongsurvey.com c
Y jonathanOlangsurvey.com 0� gS4�0
I hereby certify that I have surveyed the following described property: QO�:. 49TH COQ
BLM LOT 124, SECTION 15, T12N, R3W, SEWARD MERIDIAN, ALASKA O* Q
Anchorage Recording District, Alaska, and that the Improvements situated thereon are �' . . .
within the property lines and do not encroach onto the property adjacent thereto, that
no improvements on the property lying adjacent thereto encroach on the surveyed Q'a •.KENN H N
premises and that there are no roadways, transmission lines or other visible
easements on said property except as Indicated hereon.
F
00 �Fo ..Ls—szoz.•• 5°0�
Dated this the __Lc -e--_ Day of __ Lsr� '_�ae� ____, _l_���_, at Anchorage, Alaska 0 a �O 0
4X\4ROFfSSIONAV o�
It is the responsibility of the owner to determine the existence of any easements, �pppoo��
covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963
Municipality of Anchorage
Community Development Department Page 1 of 2
On -Site Water and Wastewater Program
4700 Elmore St. - P.O. Box 196650 Anchorage, AK 99519-6650 - http://www.muni.org/onsite - (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP171202 PID Number: 015-482-04 ❑ New 0 Upgrade
Name:
MIKE STINEBAUGH
ABSORPTION FIELD
❑ Deep Trench F-1 Shallow Trench F-1 Bed El Mound
Address
10320 CARLSON DRIVE
El Other
Phone
Number of Bedrooms
Soil Rating
depth from original grade
1 4
ITotal
GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
124
Fill added above original grade
Ft.
Gravel length
Ft.
Township Range Section
12N 3W 15
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station Tank
I Line
Ft'
1
Ft.
Well
104.5
NA
N/A N/A
25+
TANK Ej Septic 0 S.T.E.P. 171 Holding E] Other
Manufacturer
Anchorage Tank
Capacity
1250Ga1.
Surface Water
100+
NA
N/A N/A
Material
Number of compartments
Lot Line
28.9
NA
N/A N/A
STEEL
2
NA
Foundation
27.8
na
j N/AN/A
LIFT STATION
Manufacturer TCapacity
Curtain Drain
50+
na.
N/A N/A
Gal.
Remarks septic tank upgrade only
Pump on level at
in,
Pump off level at
in.
High water alarm at
in.
Pump make and model
Electrical Inspections performed by
Installer
PIPE MATERIAL Housetotank 3034 Tank to 3034
drainfield
flinstone ent.
Drainfield CO/MT 3034
Inspector Pannone Engineering Services
BENCHMARK (Assumed elevation) 365ft
Inspection est 9/8/17
dates: 2111 6/5/18
cation and description
LAT
d
3 4th
HOUSE POINT A
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
0 A�,
Conditional Approval: Date
even onnome
Approved fl�,04
8149
4,
50N
Date
I I 1byUUL1U[ I muputL—i- i- i/.doc
365
TRUE NOR SCALE 1"=
0'
3
104. BDR
SFD 1
A 8
INSTALLED NEW 1250
NI —SEPTIC TANK
126
II
, 365 1 DECOMMISSIONED EXISTING
1250g SEPTIC TANK PER MOA
I�
CODE
o
_ i
O
I
00
EXISTING DRAIN FIELD
N
124
A B
T1 29.7 39.1
T2 36.5 43.2
0 0
z z
a Q
Lu w
J
J
U OG. FG. U
365
360.4 1250 GAL 360.2
TANK
PROFILE SCALE: 1"=10'
NOTES:
PANNONE ENG SVC, LLC
P.O. BOX 102954 ANCHORAGE, AK 99510
Q'�•''
Date
6/8/18
RECORD DRAWING
PHONE (907) 272-8218 FAX (907) 272-8211.
.. ....
Scale
P.I.D. NO
T12N R3W SEC15 L124015-482-04
MIKE STINEBAUGH
10230 CARLSON ROADOSP171202
•• even.CpannORe.
`
PERMIT NO.
DRAWN ACP
Sheet
SITE PLAN
ANCHORAGE, AK 99507
2 OF 2
t4,
",0F MUNICIPALITY OF ANCHORAGE
On-Site Water&Wastewater Program
od
PO Box 196650 4700 Elmore Road
Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 ��
http:Uwww.muni.org/onsite
cluirtmut)t
On-Site Wastewater Disposal System Permit
Permit Number: OSP171202 Effective Date: 8/2/2017
Work Type: SepticTank Upgrade Expiration Date: 8/2/2018
Tax Code Number: 01548204000
Site Legal Address: T12N R3W SEC 15 LT 124 G:2536
Site Mailing Address: 10230 CARLSON RD, Anchorage
Owner: FOXSTINBAUGH LIVING TRUST Lot Size in Sq Ft: 32200
Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 4
This permit is for the construction of:
❑ Disposal Field 2 Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
ip
Received By: lf el ,4 ,0_,
� Date: ! /1 7-
Issued By: MIMI ,M1111Wi Date: 0/z..4 7
MUNICIPALITYOF ANCHORAGE
( ii.
Community Development Department �rPh• •• •9,,
Development Services Division : •9 -o.
On-Site Water & Wastewater Program
JUL 2 5 2017
ON-SITE SEWER/WELL PERMIT APPLICATION 1-
. • ti
Parcel I.D.
015-482-04 `i 01 6 8 9
Property owner(s) Foxstinbaugh Living Trust Day phone
Mailing address 10230 Carlson Rd. Anchorage, AK 99507
Site address 10230 Carlson Rd.
Legal description (Sub'd., Block & Lot) T12N R3W Sec 15 Lot 124
Legal description (Township, Range & Section)
Lot Size 32,200 Sq. Ft. Number of Bedrooms'' 9
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(®all that apply)
Absorption Field ❑ Initial ❑ Single Family (SF) ❑X
(w/wo ADU)
Septic Tank ❑X Upgrade ❑X
Duplex (D) ❑
Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
11P II qp
(Signature of property owner or authorized agent)
Permit/Rush Fees: a1Waiver Fees:
Date of Payment: 11 -(e(ti Date of Payment:
Receipt Number: Da1016% Receipt Number:
Permit No. OS1911 \102— Waiver No.
Permit App_ ::...:c
Pannone Engineering Services uc
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panengak.com
July 25, 2017
Subject: T12N R3W Sec 15 Lot 124
Tank Replace Permit Request
Design Narrative
This is a design narrative for a permit to install an upgrade 1,250g Septic Tank to replace an existing
1,250g Septic tank to be issued for this property. The existing tank has completely failed. It will be
decommissioned per code. Currently the lot is developed. The proposed system will utilize a replacement
1,250g septic tank that will be connected to the existing drain field. The existing tank is located
approximately 100'+ from the well. The proposed tank will be placed outside the existing well radius. All
required separation distances will be met.
1. Upgrade Tank Design.
A foundation clean out installed if needed.
The tank will be located: 5'+ from any property line or building foundation an GI, caay-fc fe(
10'+ from any water line iN/oal CA'elck. WruI
100'+ from any surface water 1,y. P.
100'+ from any private wells
200'+ from any public wells
The proposed installation will not affect the future development of the surrounding or existing lots.
If you have any questions or concerns, please contact me at 907.272.8218.
Sincerely,
•• l •• •M
pi f 's Steven R.Pannone g•
•-• :.a8149
Steven R. Pannone, P.E.
Owner/Civil Engineer
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchora(le, Alaska 99501 Telephone 2B4-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL, INSPECTION REPORT
~]UPGRADE
LEGAl. DESCRIPTION
Well Absorption area
~---
IF HOMEMADE:
DIS fANCE TO: Well
DISTANCE FO:
No. o1Hnes
Foundation ' Nearest lot line
Total len§[l~ of lines 'l'mnch width
Material beneath tile
Depth
PERMIT NO.
Liquid depth
PERMI F NO.
Liquid capacity in gallons
PERMI- NO. ,
PERMIT NO.
Well
DISTANCE FO:
Class Driller
DISTANCE TO: Building foundation Sewer line
OTHER
PIPE MATERIALS
SOIL TEST RAT,NG~/~
INSTALLER
REMARKS
APPROVED
72-013 (Rr~v. 3/78)
DATE
7-_1:
LEGAL
PERh'i~ T N0.
9F'F'L. I C:FlNT [::,F:l'v' I £:, I"1.
.OC:FtT I ON [:,EHFIF,:T RE:,
.EGFIL LOT ±2d.., SEC :tS
I_llI1- SIZE ,435~[E~ SQLIFlRE FEET
"CF'E: OF SOIL. F:IE:SOF::F'TII3N S'T'SI"EM I'_S: TRENCH
f:~',~.::II"ll,..It'l NI_IhlE:ER OF E:E:E)F;:OOP'IS': = d-
SOIL RFll'ING ,:iSIS! F'T,."BR>= J. 25
HE F,'EG!LIIF::EB, SIZE[ OF THE SOlE FIBSOF4:PTICli'J E;'T'~'S"I'[.::f'I I'=7:
TFIE [...ENGTF.I E:,IMENSIOI'.,I IS THE LENISTH (IN FEE'[':) OF THE TRENCH O1:?. DRFIINFIELE).
THE DEF'TH OF R I"re. ENCH OR [:'IT IS:; THE I::,ISTFII',IC:E BETP.IEEN THE LE;IJ[~:FFIL-:E OF THE
GF?.OtJND I=¢,IE:, TIDE: BO'f'"f'OH OF THE E::.::C:FFv'FtTICd',I ,::IN FEET).
"I'FIEF~:E IfS NO S;ET PlIDTH FOR TRENCHE:S.
THE GP. FI',,,'EL E)EF::'TH IS: THE MINIHIJH E:,EF'-FH OF GF,'FI'¢EL E:ETI.,.IEEN 'rile OIJTFFILL PIPE
FINE:, THE BOTTOH OF' THE E::.::C:FI'v'FITION (Ii'.,I F'EET>.
F'ERHI T FIPF:'LI CFtNT E-IRS TFIE: RESF'ONS]:BIL I T'¢ TO INFOI:RH 'FH ZS DEF'FIRTMENT f::,LIR ING ]'PIE
:I:N~;TFILLFITION INSF:'ECTIONS OF FIN"r' F.IELLS RDJFIC£:TNT "rE) THI:B PROPERT'T' FIND, -1.'HE
I'.&~P'IBER OF RESIDENC:ES I'HRT THE HELL IqILL SERVE.
................ T' ~.,-~ ~::~ ':: ~:~ ::' :[ I"-~ [='.'~ F> E::: CZ: l" I CZ[ f",~ ::':-:~ F:~ I';~: E: F: ES: G::.~ LI :[ FEI [:_7 [::: .................
E!:RCI<FILLING OF Fii",IV S'¢STEh'I P~ITHCIIJT F'INFIL_ INSF'EI:::TII:.IN I=tN[:, Flf:'F'F'.13'v'f:lL B"2 THIS;
DECF'F~I'4~:TMENT I.,.IILL BE SUB..IECT TO PROL::ECUTZON.
MINIMLIH E)ZE;'I"F~NC:E E:ETP.IEEiq FI P.IEL. L RND RN"r' ON-SI-FE SEHRGE E)ISPOSI=IL..S;'¢'=:;TEP1 IS
:I. EHZ1 FEE'T F'OF:: f:l PRI'v'FtTE NELL 01:~: ±DEl TO 2E:IEi FEET Ff;?.OH Ft F'I.IBLIC NELL [:,EF'ENE:,:[I'.,IL'~
UPON -H-iE T"r'PE OF F'UBLIC HELL.
HINIMLIH DISTFINCE FF:OM R F'RI',,,'FI-FE 1.4EI_L TO R PF:'.:['v'FiTE SEIqER LINE tS 25 FEET FINI::,
TO Fi COHHLINIT'.¢ '_:iEP.IER LINE IS 7'5 FEET.
NELL LOI"_'iS FIRE F:EI~:!I..1.IRED FIND HLIE:T BE RETURNE[:, TO THE DEPRRTHENT 1,1.ITHIN 7.::E~ DFI'T'S
OF THE HELL C:CIMPLETICIN.
OTHER REC.:!UIREHENTS MFi'T' FiPPL'T'. SF'ECIFII::FiTIONS FIND, iS:ON'="~TRUC:TIFiN DIFll3F?.FIH'.S FiRfE
FI',,,'F-/II_F:IBLE TO Ii".~SI..1.F~:E F'I~'.CIF'ER INSTFIL.LFtTIEff. L
]: E:ERTIF'"r' THFI'r
:L: I RH FIR1.,llLII~R H ITFi 'THE I;?.EQUIREHENTS FEll;.'. ON-.SITE SEP.IER5 19NE:, NELL.E; IRS SET
FORTH B'T' THE HLINIC:I PFILI-F'T' OF F:INCFIORFIC4E.
L:.:: I 1.4:[I..L IN'.S, TFILL THE 2;'¢STIZH IN FICCOR[::,FINCE HITH THE CODES.
:S: I UNDEFi::STFIN[> THFIT THE ON-.SITE :SEHER S'¢STEH Hl':¢r' REL::!IJIRE IENLFIRGEMENT IF' THE
I~?ES I [:,ENCE l S REMO[::,ELE1.> '1-0 I NC:LUDE MORE THF-IN d. BE[:,F'.OI31',IS.
PERFORMED FOR:
LEGAL DESCRIPTION:
THIS FORM REPORTS:
CONSTR
TEST
D~vid M~=
'J"~'~"~'~ ~// ~ ! NCHORAGE, ALASKA 99503
C)~'2'v ~ DATE PERFORMED:
Lot 124 & ]_2!5 Block__SW 1ZJ_,_SgQ_,E~J~bdivision_m]2N;~Wi SM
Visual Soils Examination ~ Percolnfion Tesl
DEPTH
FLEET
16'
SOIL
DESCRIP'I-ION
Peat
Gravelly, Silt
(Brown)
Sandy Silt
(brown)
(Brown)
BOTTOM OF HOLE
WAS GROUND WATER ENCOUNTERED
IF YES, WHAT DEPTH
LEd. E__ND
® - Perc zone
®S- Sample token
I~ -- Frozen zone
~ -- Water table
NOTES
Trace of
Sand
D amp
R E ADING DATE
PERCOLATION RATE: .__ 5
PROPOSED INSTALLATION
COMMENTS:
GROSS TiME
30
45
105
Kinney R, Baxter
3656 - E
NET TIME
15 min.
15 min,
15 min.
GENERAL SiTE SLOPE
min/inch
E] SEEPAGE PiT ~ [)RAIN
DRAINAGE REQUIREMENTS:
DEPTH TO H20
NET DRAINAGE
i7 i/4" i4 i/4"
28 1/2" ii ~4"
33 1/4" 4 ~/4"
36 " 3"
39 " 3"
125 sf/b_r ................
FIELD ~ OTHER
TEST PERFORMED 8~t__ I< R=~ ....... DATA CERTIFIED BY:_ Xinney ?l. Baxter
DATE:__~/~Z81 ..................
Location ...... ~ t,'~:( !/~ ~ b-r~:' ./.~: .......................................................
............ : .......
Date completed...
Depth of w~ll ~,,;~ z , .f. ...........................................
Size of casing .........
Distance to water ............ Ef ~ ...............................................................
Distance to water while pumping .......... '~P ~ ............... at rate
of .....................
........................... galloz~s per hour.
DELTA D[~ILL,~NG COF¢~PANV
P1
MUNICIPALITY OF ANCHORAGE
Development Services Department ``. 5�1'�vj Phone: 907-343-7904
On-Site Water & Wastewater Section -u`"
Fax: 907-343-7997
Parcel I.D. 015-482-04
Certificate of On -Site Systems Approval
Expiration Date: q-9-2-02-0
1. GENERAL INFORMATION
Complete legal description T1 2N R3W SECTION 15 LOT 124
Location (site address) 10230 Carlson Road Anchorage, AK
Current property owner(s) FOXSTINBAUGH LIVING TRUST Day phone (907) 242-8117
Mailing address 10230 Carlson Road, Anchorage, AK 99507
Real estate agent Jamie Harvey Day phone (907) 227-1059
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
0
Private Septic;
El
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community ;
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ o� Waiver Fee $
Date of Payment Date of Payment
Receipt Number Receipt Number
COSA # Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm Forge Engineering Phone 907-522-7773
Address 1399 W. 34th Ave Suite 101, Anchorage AK 99503
Engineer's Printed Name Michael E. Anderson, P.E. Date 1/4/2020
r'�11111u1tilh�'
Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
49th +
6. DSD SIGNATURE
�' r�""•' ,..0
10
System #1 Approved for
3 bedrooms % : MICR :� E. rnDERsoti ; - 4
♦¢�J%,
System #2 Approved for
No. CE -4381 •� o�aa
bedrooms ,##�F''•..• 1i4/2020 ..••'���'�!
Disapproved
� to°kRa Sa+ a+®��
Conditional approval for
bedrooms, with the following stipulations:
r'�11111u1tilh�'
Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
Legal Description: T12N R3W SECTION 15 LOT 124
If more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled 6/3/81
Total depth 237 ft
Cased to 237 ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) 12 in.
Date of flow test for COSA 12/10/19
Static water level at beginning of test 175.5 ft.
Comments
B. TANK DATA
Age of tank(s) 2 years
Tank type/material Septic/Steel
Measured operating fluid level in septic tank
❑ Standpipes/foundation cleanout per record drawing
Date of pumping A+ Home Services - 12/6/19
D. ABSORPTION FIELD DATA 5' Wide Trench
Which system tested (date installed) New Constructior
❑ ALL standpipes present per record drawing
Total measured depth from grade 10.65 ft (max)
Measured depth to pipe invert from grade 5.0 ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
❑ Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Comments/Deficiencies:
Parcel ID: 015-482-04
Structure served by this system
Well production at time of test 5.62 gpm
Water storage tank volume gallons
Well disinfected for coliform test? ❑ Yes ❑ No
❑ Coliform bacteria is Negative
Nitrate •313 mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by FORGE ENGINEERING
Date of Sample
12/4/19
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments:
Adequacy test date 12/22/19
Results ❑ Pass For bedrooms
Fluid depth prior to test in
Water added gal
New depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date
New Trench completed 12/22/2019. Flow Diverter Valve placed and connected to existing
trench.
COSA Checklist yellow sheet
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
1✓ Yes
if No
Community Sewer Manhole/Cleanout > 100'
0 Yes
if No
ft
0 Yes
if No ft
Neighboring Tank > 100' 0 Yes
if No
ft
Private Sewer/Septic Line > 25' 0 Yes
if No ft
Absorption Field on Lot > 100' 0 Yes
if No
ft
Holding Tank > 100' ❑✓ Yes
if No ft
Neighboring Absorption Fields > 100'
if No
ft
Animal Containment > 50' 0 Yes
if No ft
0 Yes
if No
ft
ft
If septic tank is under driveway comment below
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' 0✓ Yes
if No
ft
2] Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
1✓ Yes
if No
ft
Surface Water > 100'
0 Yes if No ft
Property Line > 5'
0 Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
0 Yes
if No
ft
Private Wells > 100'
Yes if No ft
Water Main > 10'
0 Yes
if No
ft
Community Wells > 200'
0 Yes if No ft
Water Service Line > 10'
0 Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' Yes if No ft
If absorption field is under driveway comment below
Property Line > 10' 0 Yes if No ft
Wells on Adjacent Lots:
Water Main > 10' 0 Yes if No ft
Private Wells > 100' 0 Yes if No
Water Service Line > 10' 0 Yes if No ft
Community Wells > 200' 0 Yes if No
Surface Water > 100' 1771 Yes if No ft
F. ENGINEER'S COMMENTS
New trench completed on 12/22/19 and placed
in service. Existing trench
connected to system with flow diverter valve.
G. ENGINEER'S CERTIFICATION4 QF � �
l certify that l have determined through field inspections and review a°a+aaaaaa+•a•Ra
of Municipal records that the above systems are in conformance with �+ ' 4
MOA COSA guidelines in effect on this date. ° 49th
0.—t
MICHAEL E. ANDERsar
O. CE -4381
1/6/2020
COSA Checklist yellow sheet .............
�� p""'a'+a'aa°,
it
ft
M
Lot 98A _ �_ Lot 99A I Lot 100A
E. 102nd AVENUE o
EAST 164.97'
/BLM UTILITY & R.O.W. RESERVATION
o
o
113.2'x11.6' SHED 100 PROTECTIVE
DOG RUN
WELL RADIO
\12.2'x 12.0'
GREENHOUSE L --
w/ 4' DECK 4.7'
\ SEE HOUSE
DETAIL
WIRE FENCED GARDEN 65. L i
Z
O C) X
r
01
o V?
Lot 125 ;, C ® z Lot 123
rrTW
W 3 I O
O
- SEPTIC- 4 [n
PIPES p > 4
41
I a
C
Lot 124
54,455 S.F.
2nd STORY ONLY
WEST 164.92'
I II I
50.0' 50.0'
Lot 130 Lot 131 I I Lot 132
I BLM UTILITY &
R.O.W. RESERVATIONS
HOUSE DETAIL
Scale: 1 " = 30'
2nd STORY ONLY
1
14.8' °' I
C�L____d
DECK
14.2'
24.0'
2 STORY
RESIDENCE
26.0___-{ 16.4' 24.0'
N
20.0' \-
DECK
PLOT PLAN ___ AS BUILT _X_ SCALE _?=_= 60=_ GRID _ SW 2536Project No. 19-6991A?_---
11500 Daryl Avenue, Anchorage, Alaska 99515-3049
Lang & Associates, n C, (907) 522-6476 Phone oQ.�ppp�4
(907) 522-4625 Fax o«
Professional Land Surveyors ken0langsurvey.com o O F A
jonathan®langsurvey.com �''
I hereby certify that I have surveyed the following described property:
BLM LOT 124, SECTION 15, T12N, R3W, SEWARD MERIDIAN, ALASKA
Anchorage Recording District, Alaska, and that the improvements situated thereon are
within the property lines and do not encroach onto the property adjacent thereto, that
no improvements on the property lying adjacent thereto encroach on the surveyed
premises and that there are no roadways, transmission lines or other visible
easements on said property except as indicated hereon. .
Dated this the _ Day T__ _ °2"
y of � ���.�y�_____, ____, at Anchorage, Alaska
It is the responsibility of the owner to__dete.r_mine._.the__exi_stence of any easements,
covenants, or restrictions which do not appear on the recorded subdivision plat.
49TH y*f
..........
KENNETH G. LAN o
�444�1 S-5202.
4�%R�F�SSIONA4 �Aa
11301*1461
MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIRONMENTAL I'IEALTH
DEPARTMENT OF ffEALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AUTHORITY AI>PROVAL CERTI]?ICA%]~
1. General Information Application Date ~/
(a) Legal Description (include lot~ block~ snbdivision~ section,
Location (address or
(c) Applicant is (check one) Landing Institution [--'] ; a.mer/bni~aer ~-- ·
(d) Lending Institution f~fl'$~ ~'~ ~;C~-h Telephone
Address
township, range)
(e) Real Estate Co. & Agent . _=~__.~/~t ...... 9~94_.. f__~,
Telephone ~ ~ · ~ 6 C~
(f) Mail the HAA to the following ~dress:
2. T__yj~e of Residence
Single-Family ~
Number of Bedrooms
3. Water _S~j!l_}i
Individual Well []'~
Other (describe)
Community l~--~ Public
Note: If community well system, must have w~itten confir~aation from the State
Department: of Environmental Conse~wation attesting to the legality and status°
S ewa~e D_i {~ a__l
Onsite [_~ Public [~..__~ Community r~-~ Itel. ding 'rank []]~.--~
Note: If c. ommunity well system, must have written confirmation from the State
Department: of Envirotnnental Conserw~tion attesting to the legality and status.
[Page 1 of 2]
_~_~.ineering Firm Providin~ln~ectious__.____~_~'Cesta _File· Search,.__ Data aud Information
Aa certified by my seal afflxed hereto and as of the validation date shown below, I
verify that my investigation of this Health Authority Approval shows thai: the on.-site
water supply and/or wastewa~er disposal system ia safe, functional and adequate for
the number of bedrooms and ~ype of structure indicated herein° I further varify that,
based on the information obtained from the Municipality of Anchorage files and from my
lnvemtigation and inepection~ the on-si. Ce vra~er supply and/or wastewater dispoeal
mystem is in compliance ~ri~h ali Municipal and State codes, ordinances, and regula-
tions in effect on the date of this inspection.
(ENGINEER SEAL)
DItEP ~roval / ~
~-, ,,~ ~ Y ..- ~
Approved ~/ Disapproved U Conditional
Terms of Cm~ition~ Approval
CAUTION
THE MUNICIPALITY OF 7~CHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(DHEP) ISSUES NEALTH AUTHORITY APPROVAL CERTIFICATF. S BASED SOIgLY UPON THE REPRESEbrf'-
ATIONS GIVEN IN FAtLAGILAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTEREI)
IN THE STATE OF ~SKAo THE DHEP DOES TI-IlS AS A COURTESY TO PURCHASERS OF HOMES AND
TIIEIR LENDING INSTITUTIONS IM ORDER TO SATISFY CERTAIN FEDERAL fuND STATE REQUIRE--
ME}ITSo EI4PLOYEES OF DIiEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A
CERTIFICATE IS ISSbUiD. q_~IE MUNICIPALITY OF ANCHORAGE IS NOT IIESPONSIBLE FOR ERRORS
OR OMISSIONS IN TItE PROFESSIObI~L ENGINEER'S WORK.
(DHEP SEAL)
RR4/eJ/D18
[Page 2 of 2]
7-.19-84
MUNiCIPAU~ OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
/\u0 0 8 t985'
RECEIVED
A. WELL DATA
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTFIORITY APPROVAL (HAA)
CHECKLIST- FEBRUARY 1984
264-4720
Legal DeacriptJon: ~.OT
Well Classification
Well Log Present (Y/N)
Total Depth _~ 7 Cased to
Static Water Level . J~'~
Casing Height Above Ground
Electrical Wiring in Conduit (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line t~o~
Cleanout/Manhole _ _t~O bi
If A, B, C, D.E.C. Approved (Y/N)
Date Completed . (¢'~-,~/ Yield
Depth of Grouting
Pump Set At __
Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
; On Adjoining Lots
; On Adjoining Lots
_ To Nearest Public Sewer
To Nearest Sewer Service Line on
Water Sample Collected by '~, ~". Dale __ ~/~,~'"
Water Sample Test Results _ -~'~'~'&F c'4/'~
Comments _ ~ ¢~ ~[-/~- ·· .
Da~ ~.~t.,e~ ~1/~/ Si~ 1~¢O ~o. of Compa~m.nts
Standpipes (Y/N) _ ~O Air-tight Caps (Y/N) _ ~ __ Foundation Cleanout (Y/N).
D~pre~ion ow~ T~n~ (Y/N) ~- bate L~t ¢.mp~d
Pumping/Maintenance Contract on File (YIN) ~ ; for
Holding Tank High-Water Alarm (YIN) _ ~ ' Temporary Holding Tank Permit (Y/N) ~/~ --.
Separation Distances from Septic/Hc~dln~Tank:
To Water-Supply Well J.O ~ To Building Foundation
To Property Line _ _~ ~ ~ To Disposal Field _
To Water Main/Service Line
Course
Comments
To Stream, Pond, Lake, or Major Drainage
Page 1 of 2
72-026tlt/84)
ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed
Width of Field
Square Feet of Absorption Area
Depression over Field (Y/N)
Results of Last Adequacy Test
Separation Distance from Absorption Field:
To Water-Supply Well . I I
To Building Foundation
Lot NO/'~
Type of System Design
Length of Field
Depth of Field
Gravel Bed Thickness
Standpipes Present (Y/N)
Date of Last Adequacy Test
To Property Line _
To Existing or Abandoned System on
; On Adjoining Lots
To Water Main/Service Line :.'~/O
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
Comments
To Cutbank (if present)
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
Comments
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verj, f.~d, or conformed to alI.M O.A and HAA guidelines in effect on the date of this inspection
Signed_ ~"%'~'. ~ Date ?'~'_ _,~¢'-~__~ '
Company ~~ MOA NO.
Receipt No, _~%~
Date of Payment
~ ~'/~ ~ · A · .~ ~ Engineer's Sea
MUNICIPALITY OF ANCHORAGE
' D]]VISICN OF ENVIltOF~.~ENTAL HEAI;H~
DEPARI~MENT OF HFAL~[~{ AND F~NVIRONMENTAL PROI'ECT]]ON
APPLICK~IfIN FOR HEALTh! A~$I'HOPdlTY APPROVAl., CEI~TIFI~TE
1~ C~.ne~al Infor~.ation Application Date
(a) r~gal Desr~iption (includa lot, block, subdivision, section, township, range)
(c) Applicant is (cho~) ~ndlng Institution I-~[ ~ O~r/bull~ ~,.7~ ;
Add, ess
(e) t~al Estate Co. & ~ent ........... ___ __.~
Address
Othe~ ( de scT.,ibe )
3. ~W~j.t~e._F _
Note: If ccn~aunity ¥~'.~11 system, must: have w~.~itt~n c~nfi~_,~tion f~.~ the State
Depat, i~,ent of ~]virorn~ental ~onse~vatzon attesting to the legality and status,
Is the well adequate fo~ the nunf0er of bedded]rs specified in this [{AA (Y/N)
4. ~_ej~j.~ Dis~. sal
the wastewater disposal s[stsm adequate for the ~r of bedrocms (_Y/N) ...................
[Page 1 of 21
2-15-84
5. _E_n~ineering__Fj~_rm_j?~ov_.i~d~i_n.g_I__r~l~gj2tio.ns~,' Tea. tis, I~ata and Infoumation
I certify that I have cl~oked, verified, o~ confo~'~d to all MOA HAA Guidelines in
effect on the date of this ins~tion.
Signed by
Da he
(ENGINEER SEAL)
6. DHLP Ap_p_r~ova].
Approved for__ ~_~.
Appr oved/~__~" Disapproved
Temps of Conditional Approval. _
%he Municipality of Anchorage Depa~nt of Ibalth and Environmental Protection dces
not guarantee the continued satisfactory p~fo~mn~ of the watel~ supply and/or the
wastewater disposal system° 'Enis approval indicates that, as of tl~e validation date
shc~vn above, hk3sed on the data and inforn~tion fun_nj, shed by ~] engineer regisi~red in
the State of Alaska, the water supply and wastewater disposal system is safe and func-
tional for the pnmber of beck~oc~fl and type of structure indicated°
( [~IEP SEAL)
7. Mail. the HAA to the foil.owing ad(k'ess~'
KS2/d5/s
[Page 2 of 2]
2-15-84
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
ae
Static Water I~vel ;~7 ~
Casing Height Abo~ Ground i ,I;
Electrical Wiz:ing in Conduit ~N)
Separation Distances f~cm Well:
, ..... W~ e~Sample Test~lllt~-" ~
Pump Set At
&3X3 t¢a30 a3/J _
Sanitary Seal on Casing ~)____
Depression A~tound Wellhead _(Y~
To Septic/Holding Tank on Lot IOI ; On Adjoining Lots_-)~.'~O-~'-
To Nearest Edge of Absorption Field on Lot~ //0! ; On Adjoining Lots_,~3~ff'~
TO Nearest Public Sew~ Line /(/,~ To Nearest Public Sewe~,
Cleancut/Manhole /L~,//4 To k~;a~est Sewer Service Line on Lot
Wate~ Sample Colleeted By ~..~,~t-£~ ; gate__ ?//7,/~
Be
S_~EPTIC/HOLDING TANK DATA
gate Installed -~'~/~//~-r--- - - ~ _ Size /Z~ ~__~)_ ~ No, of Ccmp~n~nt.~___~_~____
Standpipes ~/N) Ai~-tight CaDs _~N) Fo~und_a~9~lolnout.
Depression ove~ Tank (Y~ Date Last Pumped ~;~-'_~' i~
File (~N) ; fo~ '
Pumping/Maintenance
C~nt~aet
Holding Tank High-Wate'~ Alarm (.__Y/%l) ~/~ Tert~l~'ar~y ltolding Tank
~pa~ation Distan~s ~an ~ptie~oldin~ Tank:
To Water-Supply Well
To P~cpe~ty Line >/(3 ~
To, Wat~.. ~i%i n/Service Line
. . To Building Foundation ~0 I -~.
To DisPosal Field l lO'
To Stream, Pond, Lake, ca, Majb~ D~ainage
[Page ~11 of 2,],"
2-].5-..84
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed
Width of Field
Square Feet of Absorption A~ea
Depression over Field (Y/~
~_1~~' Type of System Design
Length of Field (~3!
Depth of Field
Gravel Bed Thickness
J Standpipes P~esent
Date of Last Adaquacy Test
Results of Last Adequacy Test ~/%ig/ld'tJR¢ Fd~ z/-
Separation Distance from Absorption Field:
To Water-Supply Well //Q/ To P~operty Line ~/6 /
To Building Foundation &ff~' ~ To Existing or Abandoned System on
Lot /b~//~ ; On Adjoiding Lots ~ 30 '
To Water Main/Service Line /~/~ To Cutbank(if present)
To Stream/Pond/Lake/o~ Major Drainage Course /LJ/~q
To D~iveway, Parking A~ea, or Vehicle Stc~age A~ea ~.~ ~
Comments AV ~%_q .,'W~:^~n,~/~,
D. LIFT STATION
Date Installed ~2/~
Size in Gallons /13//~
High Wate~Ala~m Level at
Tested for ff~;/l~
Electrical Codes(Y/N) ,~ ~
Counts
Dime ns ions ./t;//~
Manhole/Access (Y/N)
"Pump Off" Level at
Pumping Cycles du~ing Adequacy Test.
Vent (Y/N)
Meets MOA
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, o~ conformed to all MOA HAA Guidelines in effect
on the date of this inspection.
Signed ~---~ /A ) . ~.~ ~-~ Date ~,//./..~. ~
Cor~pany ~/')~-~-~/ /~[;~ · MOa No.
[Page 2 of 2]
2-15-84
ALASKA eI1UIROFImelqTAL COI1TROL $ RUIC S, InC.
~n§ineerinq 6 ~nuironmenlol $ludJes
JUNE 7 1984
DAVID MOOP~]
4336 102ND E AVENUE
ANCHORAGE AK 9950'7
SELLER - DAVID MOORE BUYER -
SUBDIVISION - T12N R3W SECTION 15
ADEQUACY T~T FOR SEWER SYSTEM
BDOCK - 0 IDT - 124
THE 'rfPE OF ABSORPTION SYSTf~4 IS A TR[~CH WIrl~ AN AREA OF 1134 SQFT.
THE SYSTf~4 IS (IAPABLE OF ACCEPTING 600 GALLONS OF WATER PER DAY.
THE SURGE CAPACITY OF 'IHE SYSTEM lis 9~0-G~NS.---,~-~3/~/~ ~. ,/ /, ,~.~ ......
BASED UPON THE TEST DATA THE SYS%~S4 IS ACCEPTABLE FOR A/.
3 BEDROCM I-IflNIE ......... ~
~ TEST UN WELL
THE WELL F[DW RATE WAS 4.0 GPM FOR 3.5 HOURS.
SEPTIC TANK ADEQUACY
THE EXISTING SEPTIC TANK 93LUME OF 1250 IS ADEQUATE FOR
THIS ~/BEDROCN HOUSE.
1200 ~Ucs~ 33rd Aucnu¢. $ui1¢ [~, Anchoroq¢. Aloska 99503 o[907) 561-50z10
--~.... )ATP RECEIVED
I INSPECTION APPOINTMENTS
iNSPeCTOR INSPECr~ ~- INSPECTOI~
MUNICIPALITY OF ANCHORAGE MUNICIPALITY
) DEPARTMENT OF HEALTH & ENV RONMENTALPROTECTION DEPf.
ENVIRONMENTAL SANITATION DIVISION ol ,;
Telephone 264-4720
~BUYER
~1 LING ADDRESS
E. LEGAL DESCRIPTIDN
STREET LOCATION
6, TYPE OF RESIDI-'NCE NUMBER OF,BEDROOMS
El One [] Cou¥
[] SINGLE FAMILY [] Two [] Five
[~] MULTIPLE FAMILY ~ Three [] Six
[] Other
7. WATER SUPPLY
INDIVIDUAL=
CC VlMUNITY
[] PUBLIC UTi LiTY
ATTACH WELL. LOG. A well Io§ is reauired for all well~ drilled
s~nce June 1975 =or wells drilled prior to that date, give we1
aepth (attach Io.a if available.)
SEWAGE DISPO,~;AL SYSTEM
[~ ' ~iDIVI DUAL/ON-SITE"
[] PUBLIC UTILITY
I cj~ YEAR ON-SITE SYSTEM WAS INSTALLED.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROC-=SSING CAN BE INITIATED.
72-010 {Rev. 6/79)
THIS SIDE FOR OFFICIAL USE ONLY
NUMBER OF BEDROOMS
[] ONE' [] THREE [] FIVE [] OTHER
[] TWO E; FOUR []
PERMIT NUMBER
1. TYPE OF RESIDENCE
[] SINGLE FAMILY
[] MULTIPLE FAMILY
2. WATER SUPPLY
E~'~NDIvIDUAL
[] COMMUNITY
[] PUBLIC UTILITY
Connection Verified
3. SEWAGE DISPOSAL SYSTEM
E~DIVIDUAL/oN -SITE
[]PUBLIC UTILITY
Connection Verified
[]Septic Tank or [] Holding Tank
Size: / ')~-_%'~'~ If Tank is homemade
give dimensions:
TYPE OF TANK
TOTAL ABSORPTION AREA
4. DISTANCES
WELL TO:
Absorption Ar0a to nearest Lot Line
DEPTH OF WELL
LOG RECEIVED
PERMIT NUMBER
DATE INSTALLED
MANUFACTURER
MATERIAL
Septic/Holding Tank Absorption Area
/ t~.~// ///' ~ Sewer Line
INearest Lot Line
5. COMMENTS
DATE
[] CONDITIONAL APPROVAL (letter must accompany certificate)
[] DISAPPROVED
72-010 (Rev. 6/79}