No preview available
HomeMy WebLinkAboutT12N R3W SEC 27 LT 33 Municipality of Anchorage Page I of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVlRONMFNTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-.6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~uO o~ 0:~'5 Co PID Number: 017 o~ ~ ~ ,~m~: ~ ~O~ ~O~ Wastewater System: ~New D Upgrade Phone: ~' ~ ]No. of Bedrooms: ~ ~ Deep Trench ~ Shallow Trench D Bed D Mound D Other Soil Rating: Total Depth fro~riginal grade; LEGAL DESCRIPTION Lot: ~ ~ Block: Subdiv~ion:~ Depth to pipe bottom from original 9rode: Gravel depth heneath~ pipe  ~ Section: Fill added above original g~ade: Gravel length: WELL.: ~ New ~ Upgrade Gravelwidth: ~.5 ' Ft, Nu~beroflines:~ Distance between lines: Classification (Private, A,B,C): Total Depth: Cased ¢o: "' Total absorption area: Pipe material: Driller: Date Drilled: StaticWate, Level: Installer: Oateinstalled: q . Yield: [ Pump Set at: Casing Height Above Ground: SEPARATION DISTANCES gs.p,io o Ho,ai.g ~ S.T.S.P. TO Septic Absorption Lie Holding ~ublic/Pevate Manufacturer: Capacity in gallons: Well [Oo~ ~oo',~ ~ ~ ~ Material: %~-L Number of Compartments: ~ Surface Water ~0~ ~oo% ~ --- __ LIFT STATION Lot I I Size in gallons:~ Manufacturer: ~- , ~O~[~ ~d ~ ~ .~ ~ PumpM~de~Electricallnspectionsperformedby: Curtain Drain Location and Description: Assumed Elevation: ~ E N G I ~S SEAL Inspections performed ~ /~2/' Department of He, Ith and H at {t r ioe* appg,}l ',,,:.:,,, Reviewed and approved ~/~¢~VA I ~/~ C ~M~ate: q[~/]~ .... "., 72 013 (Rev 9/91) MOA 25 ~/ SW950230 2 2 Permit No, Page of Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report LOT 3,3, T12N RSW SEC 27 Legal DescriPtion: 01705125 PID No.: ST1 ST2 C01 C02 C03 ~-93.8' NEW 1000 GAl SEPTIC TANK / A ST g/.~ IPiNA 100' WE BDRM HOUSE CO2 GRADE MTI RADIUS LOT 33 ROW RESERVli N 1 )00 GAL TRENCH · 77.0' NO FOUND , . 872r-9 ROBERT C. COWAN CE - 8901 72-013 A (Rev. 9/91) MOA 25 STATE OF ALASKA DEPARTMENT OF NATUlL~L RESOURCES DIVISION OF MINING & WATER MGMT ,WATER WELL' RECORI~ ',: ," ' · LOCATION OF WI~LL BOROUGH LOCATION/SKETCH: DEPTHS MEASURED $0REHOLE DATA~ Material Type and Color ...... Dept. oasing top nground aUrlace WELL DEPTH: DATE OF COMPLETION Depth of holm /~/~ ft From To DEPTH TO STATIC WATER LEVEL; /~. ~' ft below ~' top of c:asing ground surface METHOD OF DRILLING: ~,air rotary [] cable tool [] other ,,, _ USE OF WELL: ~'!,domestic [] irrigation ~ monitor [] public supply [] other .... CASING STICK.UPI _~ ft. Oiam: ~ icl. tO/.~_~'t W~LL INTAK~ OP~NIN~ TYPE: ~ o~en end ~ ~areened ~ perfotsted ~ open hole DePt~ of openings: --~ to . tt SCREEN TYPE: % __ Diam= in. Slot/Mesh Size: ~ Length: .... ft GRAVEL PACK TYPE: Volume used: Depth to top; GROUT TYPE, ~.~c:> ~:~'..~_ Depth: from tt DEVELOPMENT METHOD! Duration: ~.~? PUMPING LEVEL AND YIELD: ft after ...~.~__~ _ hfs pumping_ ~ __gpm PUMP INTAKE DEPTH: ft Horsepower; ~-- WELL DISINFECTED UPON COMPLETION7 ~)('ES [] NO CONTRACTO~R ,NFORM~;: .~ ~. REMARKS, .~ ~& PLEASE MAIL WHITE COPY OF LOG TO: . DNR/DIVtSlON OF MINING & WATER MGMT Sioneture OtAUt~On 3601 C sg~ Suite 800 Anchorage, AA 99503-5936 PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW950230 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:COCKLIN TOMMY & TAMI OWNER ADDRESS:IS01 ATKINSON ANCHORAGE, AK 99504 DATE ISSUED: 8/21/95 EXPIRATION DATE: 8/21/96 PARCEL ID:01705125 LEGAL DESCRIPTION: T12N R3W SEC 27 LT 33 LOT SIZE: 108900 (SQ. FT.) NUMBER OP BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IH ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343 4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: DATE: DATE: HEALTH AUTHORITY APPROVALS SEWER &WATER INSRECTION ENGINEERING STUDIES ANDREPORfS WELt INSPECTION &FLOWTEST ROAD DESIGN SOJLTEST PERCOLATION TEST STRUCTURAL & MECHANICAl INSPECTIONS ROBERT C, COWAN, RE. ROBERT A. SHAFER, RE. August 7, 1995 CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 33, T12N, R3W, Section 27, S.M. Request you issue a permit to drill a well and install a septic system to serve thevthree bedroom house on the referenced property. P~f~D A test hole was excavated and a percolation test performed. The approximate location of the test hole is located on the attached site plan. At the time of excavation no water was encountered and after seven day ground water monitoring, the monitoring tube was found to be dry. This property has enough area for a future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. There are no points of contamination within the proposed well radius which can be seen on the attached site plan. If you require additional information, please contact us. Sincerely, Robert C. Cowan, RCC/gk Enclosure 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 Sll'E PLAN DESIGN 0 >~o ,c) Municipality of Anchorage DEPARTMEN'r OF HEALTH & HUMAN SERVICES .... 825 L Street, Anchorage, Alaska 99502-0650 ' LEGAL DESCRIPTION: Township, Range, Section: 1 2 3- 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19- 20~ /m L 'F .~ ,v y / c i~ fJ.O rt. WAS GROUND WATER ,k/ O ENCOUNTERED? SLOPE SITE PLAN g IF YES, AT WHAT /4 oL DEPTH? /¢ p E Monitoring7 . ~/~ "/ Dale: Reading Date Gross Net Depth to Net Time Time Water Drop fr/i/~s- 3:~3 3.,~ ,, _ PERCOLATION RATE [ (m~nutes/mch) PERC HOLE DIAMETER __ TEST RUN BETWEEN ~ __ FTAND ?~' FT ////J // PERFORMED By: Sg~5 ENGI NEER :¢~¢~.~'/%~' ~//~'7~O~fl,-,.-~- CERTIFY THAT/~HIS T,ST WAS PERFORMED IN 72-008 (Rev. 4/85) ROBER'¥C. COWAN, RE. ROBER'rA. SHAFER, RE. SEWER & WA1ER MAIN EXTENSIONS SEWER & WATER ~NSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOWTEST ROAD DESIGN PERCOLATION TEST STRUCTURAL & MECHANICAl INSPECTIONS ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 REFERENCE: Lot 33, T12N, R3W, Section 27, S.M. August 7, 1995 GENERAL: 1. The scope of this project includes the installation of a 1000 gallon septic tank and leachfield trench to serve the three bedroom residence located on the referenced property. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Ail standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 17034 NORTH EAGLE RIVER LOOP . SUITE 204 . 'EAGLE RIVER, ALASKA 99577 Page Two Lot 33, T12N, R3W, August 7r 1995 Section 27, S.M. Septic tanks installed with less than 4 ft. of cover shall be insulated. A foundation cleanout shall be installed one to four feet from 'the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate 'the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed--up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Page Three Lot 33, T12N, R3W, August 7, 1995 Section 27, S.M. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in theM ' ' 'unlclpallty of Anchorage: _Type of Pipe_ Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick burial polystyrene (Dow Chemical Company equal). extruded direct Styrofoam HI or Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. Ail leachfield grave]_ (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the ~200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. Page Four Lot 33, T12N, R3W, August 7, 1995 Section 27, S.M. INSPECTIONS: Typically there will be a minimum of three (3) .nspectlonsi required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of 'the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etco Thus, the inspecting engineer is 'to be contacted at least 24 hours prior to the start ofconstruction.' If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. Page Five Lot 33, T12N, R3W, August 7, 1995 Section 27, S.M. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER • • �-� Municipality of Anchorage °r i E (; On-Site Water and Wastewater Program (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 017-051-25 Expiration Date: 12—c 01. GENERAL INFORMATION Complete legal description _T12N R3W SEC 27 LT 33 Location (site address) _5055 NOGAARD ROAD Current Property owner(s) _JOHN MAIN Day phone Mailing address _SAME Real Estate Agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer 0 Waiver/Variance request for: Distance: Received by: /A ._ Date: 7/0/// I COSA to be released to the engineer,u ess otherwise requested by the engineer. COSA Fee $ 62C, — Waiver Fee $ Date of Payment 1(1 3 1 I( Ck10Vgo Date of Payment Receipt Number o;asf;)" .(r Receipt Number COSA# O`g_n 11-1Waiver# • 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm MIKE N ANDERSON, P.E. Phone 727-8864 Address 4661 NATRONA AVE. Engineer's Printed Name MIKE N ANDERSON, PE Date 8/28/18 may , ��;• o, ep • o `� �. i.J`- ` ` er,• a cVo o/ v e !'� N. c s P n 0 0 0 ., 6. DSD SIGNATURE Y ;=�� P.1icH,�El. q{.;p�R;;,;, ';� Ee•' ,J x System #1 Approved for bedrooms ( ` ' . ••� / System #2 Approved for bedrooms. E�`cd n: ;K,ly • Disapproved. Conditional approval for bedrooms, with the following stipulations: ON-SITE WATER AND -_ WASE RAMR c pROG Y (� Original Certificate Date: q - (C9 e The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 10.10.12 doc If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system _ Certificate of On-Site Systems Approval Checklist Legal Description: T12N R3W SEC 27 LT 33 Parcel ID:_017-051-25 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N)Y Date completed 3/29196 Sanitary seal (Y/N)Y Wires properly protected (YIN) Y Total depth 149 ft. Cased to 149 ft. Casing height (above ground) 12"+ FROM WELL LOG AT INSPECTION Date of test 3.29-96 6.29-2018 Static water level 129 ft. 130 ft. Well production 8 g.p.m. 4+ g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate 2.411 Omg/L Arsenic: ND ug/L Date of sample: 8-30.2018 Collected by: Mike Anderson B. SEPTIC/HOLDING TANK DATA Tank Type/Material STEEL Date installed 9.4-95 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N)Y Depression over tank (Y/N) N High water alarm (Y/N) Y Date of pumping 6-31-18 Pumper AROUND THE CLOCK C. ABSORPTION FIELD DATA Date installed 9-4-95 Soil rating (GPD/SF) 1.2 System type DEEP TRENCH Length 37 ft. Width 2.5 ft. Gravel below pipe 6.0 ft. Total depth 10 ft. Eff. absorption area 444 ft2 Monitoring tube Y Depression over field N Date of adequacy test 6.29-2018 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test 38 in. Water added 500+gal. new depth 55 in. Elapsed Time: 1440 min. Final fluid depth 41 in. Absorption rate >=_500+ g.p.d. Any rejuvenation treatment(past 12 mo.) (YIN &type) N If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off" level at in.High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main 100'+ Public sewer manhole/cleanout NA Sewer/septic service line 50'+ Holding tank 100'+ Animal containment areas 100'+ Manure/animal excrete storage areas 100'+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5' Water main NA Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10 Water main 10 Water Service line 50'+ Surface water 100'+ Driveway, parking/vehicle storage 50'+ Curtain drain NA Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION * ' •� 49TH !, I certify that I have determined through field inspections and review of Municipal records that the above systems are in �•• :MICHAEL N. Ah'DFRSCN conformance with MOA COSA guidelines in effect on this date. raGi•. C /9#69 •' `' sJ . Engineer's Printed Name MIKE N. ANDERSON, PE 'QFp � •'•�,��;,;'� Date 813112018 l``t\Nx ;N'%"-~ COSA canary sheet_2-6-15.doc