HomeMy WebLinkAboutT12N R3W SEC 27 LT 55 REM?.."'7
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP221462
Work Type: Septic Upgrade
Tax Code Number: 01809247000
Site Legal Address: T1 2N R3W SEC 27 LT 55 REM G:2936
Site Mailing Address: 4301 DE ARMOUN RD, Anchorage
Owner: KRISTIANSEN ODD & VIRGINIA
DesignEngineer: P1AVAGNE E+4G N E Rivv
a
C 4-M
This permit is for the construction of:
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy
Effective Date
Expiration Date:
ent
J
Department
1/5/2023
1/5/2024
Lot Size in Sq Ft: 45164
Total Bedrooms: 1' 3
❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
4-17- Chan -S, W TOC"l CotAll-r,
f Ce��xed 5 Sit e U f0 r G 4-M
Issued By:
Date:
Date: Z 5
MUNICIPALITY OF ANCHORAGE
0.
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 018-092-47
Property owner(s) Virginia Odd Day phone
Mailing address 301 De Armoun Anchorage AK 99516
Site address 4301 De Armoun Anchorage AK 99516
Legal description (Sub'd., Block & Lot) T1 2N R3W SEC 27 L55 REM
Legal description (Township, Range & Section)
Lot Size 45,164 Sq. Ft. Number of Bedrooms
APPLICATION IS FOR:
APPLICATION IS AN: TYPE OF -DWELLING:
(® all that apply)
Absorption Field X❑
Initial El Single Family (SF) X❑
Septic Tank X❑
(w/wo ADU)
Upgrade X❑
Duplex (D) ❑
Holding Tank ❑
Renewal ❑
-
— Multiple Dwellings ❑
Privy ❑
(SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:—
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
0 "�'�
(Signature of property owner or authorized agent)
Permit/Rush Fees: '<_0r Waiver Fees:
Date of Payment: / (%9V_ Date of Payment:
Receipt Number: (� Receipt Number:
Permit No. ins 10 92 Waiver No.
Permit App__- :- :_..,.c
Municipality of Anchorage
Onsite Water and Wastewater
REVIEWED FOR CODE COMPUANC
0SX231007, Deb Mckenfuss, 008
C&M ENGINEERING SERVICES C�0 �J
Ph: 907-854-5558
Municipality of Anchorage
Onsite Water & Wastewater Program
4700 Elmore Rd Anchorage, Ak 99507
RE: Proposed Septic System for T12N R3W SEC 27 L 55 REM
Dear Reviewer,
The above referenced property is currently served by an older FAILED septic system. We are requesting
a change order to the existing open permit to reduce the bedrooms size from 4 -bedrooms to 3 -bedrooms
as requested by the owner.
Our review of available documentation and field investigation show that this project will not adversely
impact any nearby Wells, Wastewater disposal systems, replacement disposal sites, or drainage flowing
onto and off of the subject property.
As shown on the plan, the tank and field will be greater than 10' from the house foundation.
The tank will be of MOA approved construction.
The tank shall be covered with a minimum of 2" moa approved insulation and 3' of cover or a minimum of
4' of cover without insulation.
The bed will be located adjacent to a testhole performed by PES. The testhole showed groundwater at 4'
and free draining soils. The bed will be an elevated mounded system with a minimum of 2' of filter sand
below the sewer rock. The bed will be installed on a slope of approximately 3%. A width of 12' was
selected to reduce the amount of the bed that has to be elevated above existing grade. A profile view
drawing is provided to show the bed and extents of fill relative to the slope.
Upon completion of the installation, a record drawing will be submitted showing the location of the new
tank, leach field, well, and other applicable features.
Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854-
5558 or by email cgbalzarini(a)_gmail.com with any questions or concerns.
Sincerely,
Charles Balzarini, PE
7/18/23.1981; 0" A04
0`
c� o
0
'CHARLES G BALZARINI"
CE13854
�1��RR0FESSIOl ..7
C&M ENGINEERING SERVICES
907-854-5558
Septic Design Calculations
Residence: LOT 155 REM
Wnicipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE CONIPUANC
08X239007, Deb 140ckenfuss, 08108
Co4zj
system type: Conventional
type: BED
A
Application Rate
gpd/sqft
number of bedrooms 3
br
Water usage/bedroom 150
gpd/br
Water Usage 450
gpd
system type: Conventional
type: BED
A
Application Rate
gpd/sqft
required absorption area
643
sqft
trench width (W)
12
ft
MIN gravel depth (D)
0.5
ft
Min Required Length:
53.5833333
ft USE 54'
Sand Thikness:
2'
MIN
Max Excavation Depth:
0
to bottom of
ft
rock
Groundwater Depth:
4'
REFER TO PLANS FOR DETAILS OF CONSTRUCTION
Calc By: CGB Date: 7/19/2023
'CHARLES G BALZARINI'
CE13854
AW�'PROFE5S10��` �
NOTE: INSTALL ALL COMPONENTS IN ACCORDANCE WITH MUNICIPAL CODE,
APPROVALS, POLICIES, AND MANUFACTURER'S RECOMMENDATIONS.
AN ASBUILT SURVEY MUST BE COMPLETED AFTER THE INSTALLATION OF THE
SEPTIC SYSTEM COMPONENTS.
' INSPECT EXISTING LINES FOR DAMAGE, SLUDGE, AND / OR BLOCKAGE
I
I I
I I
I I
WELL
I I
II_ --------
I ' I
I � I
I I
I I
3 BR
�I HOUSE
L------------I
LOCATE AND DECOMISSION ��----__
OLD LEACHFIELD
1 I
100' WELL RADIUS
1 I
1
j 2" MANIFOLD
1 I
1 I
1 I
12X54 BED
WITH 2'+ MOA SAND.
MAX EX. DEPTH 2' TO BOS �\
INSTALL MT WITHIN 1' OF
EACH CORNER OF BED
I I
3 EA. 1.5" LATERALS
WITH 1/8"HOLES AT 2' SP
I I
I I
I 1
I i
I I
I I
I
I I
LEGEND 100WELL RADIUS
O CLEANOUT i
I I
O MONITOR TUBE I I
I 1
I I
® TEST HOLE I I
I I
FOR
%� AW31007,
i* 49 TM '
CHARLES G BALZARIUi
rr ��� • CE -13854 -0,
AMW
y
DECOMMISSION
OLD TANK
PER MOA
REQUIREMENTS
NEW SEWER LINE
DUAL COs
ter'/ NEW 1250 GAL
MIN MOA APPROVED
5.6 STEP TANK. RATED FOR
SHALLOW GROUNDWATER
PES
TESTHOLE
1' MOA /
CONTOURS j
SLOPE
DOWN TO THE
SOUTHWEST
NOTES:
COQ
TOE
OF MOUND
1. THE PROPOSED SEPTIC SYSTEM
100' FROM ANY PRIVATE WELLS
200' FROM ANY PUBLIC WELLS
100' FROM ANY SURFACE WATER
I I I
IS GREATER THAN:
C&M ENGINEERING SERVICES
907-854-5558
LEGAL DESCRIPTION: T12N R3W SEC 27 LT 55 REM vv
OWNER: KRISTIANSEN I DATE: 7/28/23 REV:O 1 DRAWN: CBJ REF:
SITE PLAN
NOTE: INSTALL ALL COMPONENTS IN ACCORDANCE WITH MUNICIPAL CODE,
APPROVALS, POLICIES, AND MANUFACTURER'S RECOMMENDATIONS.
AN ASBUILT SURVEY MUST BE COMPLETED AFTER THE INSTALLATION OF THE
SEPTIC SYSTEM COMPONENTS.
INSPECT EXISTING LINES FOR DAMAGE, SLUDGE, AND / OR BLOCKAGE
6" TOPSOIL AND SEED
PER MOA REQ'S
FILL MOUND
ORIG GRADE 4" INSULATION
2.0' ¢--- 4.0' b 4.0' A
_—_— 6" EFF BED, ---
__ _ _ - - -T
-------- -- t t t t t t t t t t t
2.0 . t t t t t t t t t t t t 2.0'
I_ t + t t t + t + + + + +-
____________._SEASONAL HIGH GWT, PER PES TH•--------- ---
CROSS SECTION DOES NOT SHOW ALL COMPONENTS OF SYSTEM SUCH AS FILTER FABRIC.
CONSTRUCT SYSTEM PER MOA REQUIREMENTS. DO NOT OVER EXCAVATE.
2.0'
3
C&M ENGINEERING SERVICES
907-854-5558
LEGAL DESCRIPTION: T12N R3W SEC 27 LT SS REM
OWNER: KRISTIANSEN DATE: 7/28/23 REV:O 1 DRAWN: CBJ REF:
SCHEMATIC SECTION
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221462, Deb Wockenfuss, 01/05/23
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221462, Deb Wockenfuss, 01/05/23
IL
Sir
Al 7 1n ^ A
N
C�-
N-
B 'N
M."
I
(f" 0',/)
0.5
O
co
OE
cl(D
tv,
Q 2
C6 a
CU a)
JO
-0
C;)
O
CD Q
6 \n
1
0 -60 .0
cn
co 0
u
<
O oo 0,
cc6
00
0 to
c00-
-0,
� IK
cl)
< t
0--- 0
<
2cc
C,
F<-c
CU
C:
cl, .0
E2
(D
:S 2 75N c
01
0
-6
Ct c
w
0 C7
C;
N c
o c C
>, U- UJ
2 - co
�U) — E m
.S -o a>) E Z5 <
0
2 2 2
0 Co CL 0-.Cn 0 m
:9 E w E m w
cr, -
—
CL 0
CZ c CCU
0
I
CD 0 > 0 X
cy) E 0 <
Cb
c a >, Z
0 -6 CU al t-
>
0 1 2
"ZI,
C\I.
0 CL 0 70 CL
cn
Q '0 w 2 n!E
—rn
I,
I
0
0
VzV
Z
LU
0
Moo W
fr Z
M o
Owa:
W
Cr T
o I
ir w
z
0E-3:
LLJ Z0
cr 0 m
LL (n
Z
o98
Z
Z COm M ui
UJ
2 w <
uj U)
<co 0
2:
w I- CL
~V~-W DRILLiNG, Inc.
P~O. Box4-1224 · 1310C International Airport Road
(907) 274~461]
ANCHORAGE, ALASKA 99509
DRILMNG LOG
Well Owner. { ;~ ) ~ ' ( ~ ' ~4 ~ ~ .Use of We]]
Location (address of: Township, Range, Section, if known; or distance main road.
Size of casing ~r ~ '' Depth of Hole_ 'i ,';; ~eet Cased to__ ] ¢¢~ _feet
Static water level I - > ft. (~b,O,,~,~,) (below) land surface. Finish of well (check one) open end ( , );
Screen ( ); Perforated ( ).
Describe screen or perforation
Well pumping test at ,;..~i gallons per (hour) (minute) for ] _hours with i~lo ft.
of drawdown ~rom static level.
Date of completion ]'J ~;~0'g~ i'07%
WELL LOG
Depth in feet from
ground surface Give details of formations penetrated, size of material, color and hardness
2 -- STATE