HomeMy WebLinkAboutT12N R3W SEC 27 LT 69 N2
~ DATE RECEIVED
INSPECTION APPOINTMENTS
'~FIv] E ~ME TIME
,/2
DATE DATE DATE
INSPECTOR INSPECTOR INSPECTO~
MUNICIPALITY OF ANCHORAGE MU~LWA~ ....... OF ANCHORAGE
~ 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL PROTECTION
ENVIRONMENTAL SANITATION DIVISION
Telephone 264-4720 MAR 2 0 1981
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND
DIRECTIONS: Complete all parts oH pago 1, Incomplete requests will not be processed, Please allow ten (10) days for processing,
1. PROPERTY O~ER .~n ~. PHONE
c' c':. /
MAILING ADDRFSS --.~
PROPERTY R%SIDENT (If different fr~above) [ PHONE
2, BUYER "- ~ ~ PHONE
MAILING ADDRESS ~
MAILING ADDRESS ~ ' ' r
4, R~ALTOR/AGENT PHONE
MAIkI~G
NUMBER OF~BEDROOMS
[] One [] Four
~ Two [] Five
Three [] Six
[] Other
7. WATER SUPPLY
~ INDIVIDUAL~
COMMUNITY
[] PUBLIC UTILITY
8. SEWAGE DISPOSAL SYSTEM
~ INDIVI DUAL/ON-SITE
[] PUBLIC UTILITY
* ATTACH WELL LOG. A well log is required for all wells drilled
since June 1975. For wells drilled prior to that date, give ~vell
depth(attach og fgva abe) ~2~.%/ c'bJy;/ie.¢(
~ ~ / V~A. ON-~ SVS~ WAS
/
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-O10 (Rev. e/79)
Tobben SpurHand P.E.
8155 Cranberry St.
Anchorage, Alaska 99502
Phone (907) 243-5302
MUNICIPALITy OF ANCHORAGE
OEP]. OF HEALTh' &
ENVIRONM[NTAL P:'OTEC?ION
MAR :3 J. 19E~11
Mro Charles ~J.~ch
PoOoBoX 10-1797
Anchorage, J~.aska 99511
March 30, 1981
SEWER AD E(~U A C Y TEST
Legal N~,Lot 69, Sec. 27, T12N, R3W, S.M.
Location On Cannon Road off DeArmoun
Owner Charles Filch
]~esidence Trailer with Lean To
Water On Site Well
Sewer System No MUnicipal Records
1000 gal tank from pumping receipt
Absorption System ][~g Crib
Absorpt ion ~rea Unknown
. Installation Date 1970
Date of Test March ~5 to March 29 1981
Test i~rocedure System was p~q~ed by owner on March 21, 1981. On March 25
the system was inspected. Tank was almost ful].~ liquid depth
in crib was 18 inche~;. Top of crib is 2 feet below ground, crib
is b feet deep.
~~m On March 1OOO ga_l was dw~tped into crib, water level rose to
O~ ~ ~ '
~'~" ~ '"~(~J~ Test was repeated on March 28. Uater was dumped into crib in
,;~. 49~/{ " %.~ O0 g~ ~ncremen~s and the followzng zeadzngs t~en
· .~ .....~. ·.
~.~$ Water Volume Liquid Depth
ooo
~ was 2um~e~, A~pz'ox~mte~y 1~0 ga~ wa~
Test i~esults: After 11 yeqrs of operation the bottom two feet of the cr~b are
barely percolating. The top two feet are in good shape and are
absorbing water at a rate of 1500 gal per 2b hour period.
This absorption rate is in excess of the municipal requrement.