Loading...
HomeMy WebLinkAboutT12N R3W SEC 22 LT 44A ' Municipality of Anchorage Page ,. DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 on-site Wastewater Disposal System and/or Well'lnspection Report N~: ~.~ ~ .~~. Wastewater System: ~New 'D Upgrade Address: ' ~l~ ~ ~ ~-~G~' ABSORPTION FIELD Phone: ~_,t~ ~No.~drooms: ~DeepTrench ~ Shallow Trench DBed ~Mound .~Other Total Depth fr~m original grade: · LEGAL DESCRIPTION so,,~,i~: ~. ~/s~.~,. ~.~- ~'~' Lot: ~ A Block: ~ Subdiv~ Depth to pipe~,~/- z' ~ ~b°lt°m from original grade: Ft. Gravel depth beneath~.opipe Ft. Township: ) Range: m section: Fill added above original grade: Gravel length; Number of lines: 0ist~e~tween lines: ~ Q New D Upgrade Gravel width: ~/~ Ft. t / Ft. Classification (Pri~~ Total Oepth: Cased To: Total absorption area: Pipe matePal: Driller: ~ StaticWaterLeve): Installer: SEPARATION DISTANCES ~s~c ~ Holding ~ S.T.E.P. To Septic' Absorption LiE Holding ~ublic/Private Manufacturer: Capacity in gagons: Prom TaBk Field Station Tank ~ewer Lines ~ . ~ Lot Size in gallons: ~ Ma~ Foundation ~ ~ ~ I[ ' BENCH MARK Remarks: Location and Description: Department of Heal~ and ~man ~rvices approval 't ;~;;',.. .. ....." ~;~ Reviewed and approved by: ~2 ~~Date: /~ --/~-~ 72~13 (Rev, g/91) MOA 25  AS-BUILT DRAWING / AC = 115 ~ / BG = ~CH. ~NGTH ~5'7 9H = H5,5 ~O~ORE ::TREN~H~ AR B ~ i PVC (D3034). ~ . 100 FT, RADIUS PREPARED BY~ ALASKA WATER & ~ASTEWATER, ~4 ,.. ....'~, AS-BUILT DRAWING NEW 1250 GALLON SEPTIC TAN[. ANCHORAGE TANK, INLET INV, = 95,03, OUTLET INVERT = g4.77 TANK SET LEVEL WITHIN .00 FEET, . FRDH HDUSE, INVERT AT FOUNDATION C/0 = 96,6 LENGHT DF PIPE FRDN FOUNDATION TO TANK IS APPROXIMATELY THE SLOPE = ~X TD 3~, GROUNO ELEV, AT TANK VARIES (99,6 +) MINIMUM COVER = 4 FEET, GROUND ELEV, OVER TRENCH IS 9&,D DR = 3~. FEET.~.. FOR LOCATION OF M, Ts gEE PLAN DRAWING /--FILTER FABRIC OVER DRAINROCK B, BOTTOM DF TRENCH = 05,8 C, ND GROUNDWATER TD DEPTH DF lB FEET, TRENCH LENGTH = 85 FEET E, TOTAL ADSORPTION AREA : 1360 SD, FT, SEPTIC UPGRABEI T18N~ R3~/, SEC 88~ LOT 44A, PREPARE]) FDRI BRUCE GtFFEN ALASKA .~/ATER & WASTEWATEE DATD 10/8/9G ])WN, GARNESS ~BENCHMARK IS TOP OF WELL HEAD, ASSUMEO ELEVATION = 103,58 :ALE~ NTS g~ $ 00'0~'00" r S 00'04'46" ~ 33u,o2' (M) N 00'04'0o" w ~3o.o5' (M) ~ ~ oo'o,~'oo" w_. ~o.oo' OUR ROAD MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF 1 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW960055 DESIGN ENGINEER:ALASKA WATER & WASTEWATER SERVICES OWNER NAME:DICKEY CLOSEY F OWNER ADDRESS:il525 OUR RD ANCHORAGE, AK. 99516 DATE ISSUED: 4/22/96 EXPIRATION DATE: 4/22/97 PARCEL ID:01514235 LEGAL DESCRIPTION: T12N R3W SEC 22 LT 44A LOT SIZE: 206250 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AACS0) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: Ao OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AMD HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: . ,/ ~ DATE: ~/~'~ B,L,M, LBT 37, SEC 22., T12N, R3W., S,M,, ALASKA. LOT IS UNDEVELOPED, HOWEVER THERE I2 AN BLD WELL BN THE PROPERTY WHICH IS >100 FEET FROM THE PROPOSED SEPTIC SYSTEM UPGRADE BN LOT 44A NBRTH PRBPERTY LINE B,L,M, LOT 45, SEC 22, T12N, RSW, S,M,, ALASKA, LOT IS DEVELOPED, HOWEVER, ALL WELLS AND STRUCTURES ARE >200 FEET FROM THE PROPOSED SEPTIC SYSTEM UPGRADE ON LOT 44A, SEPTIC UPGRADE : B,L,N LBT 44A, SEC 22, T12N, R3W, S,M,~ ALASKA PREPARED FBR ~ BRUCE GIFFEN PREPARED BY~ ALASKA WATER & WASTEWATER, DATE, 4/1/96 I DRAWN' GARNESS ISCALE: 1' = 100' '. ~E~,= 8~,8~ NORTH PROPERTY LINE ? ........ ~ ....... ~ ............ ~.~:, ~.~., .. 'IRESERVE TRENCH LENb/H = ua ', ', : D~ A'"'D ~itH'IN":~O ~- ~B ~E CBNSTRUCTE~ IN FUTURE,~ ....... ~:EE:~< ~ :~89 7¢ ..... ' , ~j :~' ~:7 C/D PRIMARY TRENCH LENGTH = 85 ~ // y~s~ ~ :~'K C/~ 1~50 GALLBN SEPTIC TANK SEWER LINE, .4 INCH CIO, DIA, PVC, D3034, SLOPED 1/4 INCH PER:FOOT MIN, 'ION C/D NEW HOUSE EXISTING BOUNDARY WELL 100 FT, RABIUS DF PARKING AREA · NEAR DRAINFIE/ SEPTIC UPGRA3E ~ B,L,N LOT ~4A, SEC NB, TI~N, R3W, S,N,, ALASKA PREPARE3 KDR ~ 3RUCE GIKKEN ~REPARED DATE, / 4/I~96 %/,,./,,,~, ALASKA WATER & WASTEWATER, InRAWN~ GARNESS I1" = 40' ~07~L TRENCH LENGTH ~ ~SFEE~ TOTAL ABSORP~ON AREA = ~60 SQUARE FEE~ WITH NATIVE SOIL AND MOUND. TOPSOIL & RESEEDING SHALL BE THE REPSPONSIBILITY OF THE PROPERTY OWNER. --ILTER FABRIC SILT BARRIER. 2 INCHES OF BOARD INSULATION IF SOIL COVER IS LESS THAN 3 FEET. INSULATION SHALL COVER THE ENTIRE WITH OF THE TRENCH. 4 INCH DIA., ASTM F810 PERFORATED P.,IPE. INSTALLED WITH HOLES DOWN. PLACE 2" OF DRAINROOK OVER TOP OF PIPE, AND ACROSS THE ENTIRE WIDTH OF THE. TRENCH. PiPE SHALL BE LEVEL (WITHIN ,01 FEET). TUBE (TYP). PERFORATED IN DRAINROCK. NOTE: FEET MIN. 1. TRENCHES SHALL RUN PARALLEL TO THE SLOPE CONTOURS. 2. FOR LOOATION OF OLEAN-OUTS AND MONITORING TUBES, SEE SITE PLAN. 3. CONSTRUCTION PRACTICES, AND MATERIAL SPECIFICATIONS SHALL COMPLL Y WITH ANCHORAGE MUNIOIPAL CODE 15,65, "WASTE- WA TER DISPOSAL REGULATIONS". 4. INSTALLATION SHALL COMPLY WITH SPECIAL PROVISIONS AS. NOTED ON THE SEWER PERMIT. 5, SMEARED BOTTOM AND SIDEWALLS SHALL BE RAKED. DRAINROCK SHALL BE SCREENED PER M.O.A. SPECIFIOATIONS. DIRTY DRAINROCK WILL BE REJECTED. TRENCH DETAIL: B.L.M LOT 44A, SEC 22, T12N, R3W, S.M PREPARED FOR: BRUCE GIFFEN ALASKA WATER & WASTEWATER SERVICES DA TE: 4/1/96 D WN: GARNESS SCALE: NTS Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 925 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG ~ PERCOLATION TEST PERFORMED FOR: ~> '~--" ~'~' ~"~' LEGAL DESCRIPTION: [.. O ~"' 1 2 5 6 7 8 9 10 11 13 14 15 16 17: 18 - 19- 20- DATE PERpO~ME~ Township, Range, SEction: ";' SLOPE SI~E PLAN ." WAS GROUND WATER ENCOUNTEREO? DEPTH? --Monitoring? ~o ,s IF YES, AT WHAT I~ /~ . pO Gross Net ' Depth to Net Reading Date Time ·. Time . Wate¢ Drop ~. ,, ~ ~ ~ ~ '/+', ' PERCOLATION RATE /o-~' . (n~inutes/inch) PERC HOLE DIAMETER TEST RUN BETWEE" ~'"~'.FTAND 9 F~ 72-008 (Rev. 4/85) Mun c parity of AnChorage DEPA.R,T.MENT OF HEALTH &'HUMAN SERVICES 825 'L' Street, Anchorage, Alaska 99502-0650 SOILS LOG ~ PERCOLATION TEST . DATE PERFOF{MIS~ LEGAL DESCRIPTION: ~T ~ A . SLOPE 1 3 ~L 4 7 11 13- 14 15 16- 17 19- 20- ;OMMENTS IF YES, AT WHAT DEPTH? 8lTD PLAN Gross N9t · Depth to Net Reading Date Time Time Water Drop , . ~ ~ /~z PERCOLATION RATE ~''-7 , (minutes/inch) PERC HO~.E DIAMETER ~' '~FT AND ~ , FT TEST RUN BETWEEN { FT ACCORDANCE WITH ALL STATE AND MUNJCIPAL GUIDEL NES IN EFFECT ON TJ418 OAYE, DATE: I'~-,//~ {/?~- · 72-008 (Rev, 4/85} 'Facsimile Transmittal Alaska Water & Wastewater Consulting Engineers Phone: (907) 337-6179 Fa,Y: (907) 336-3246 8471 Brookridge Dri~re Anchorage, Alaska 99504 Date: Attention: From: Jeffrey A. Garness, P.E., M.S. Number of pages (including this cover): Comment(s): Reply requested: [] Yes [] No 8471 Brookridge Drive ~ Anchorage ~ Alaska Phone (907) 337-6179 ~ Fax (907) 338-3246 Consulting Engineers April 1, 1996 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref~ Sewer Permit for B.L.M. Lot 44A, Sec 22, T12N, R3W, S.M. To whom it may concern: The subject property is served by an existing private well (letter from driller attached), and a private septic system. The existing septic system is undocumented and going to be abandoned. The property owners are planning to construct a new 4 bedroom house on the site this summer., consequently, a new septic system is required. Comments regarding the proposed upgrade are summarized as follows: 1. Soils: The test hole revealed that the soils were primarily SM/ML overlaid with 2-3 feet of till (silt, sand, gravel mix). The percolation rate of the SM/ML soil was determined to be 6.5 minutes/inch to 27 minutes/inch, however, the soils visually appeared to be tighter. The overlying till was not tested, but visually appeared to be considerably more l~orous. To be conservative, I am proposing to use an application rate of .45 gallons/day/ft~. The design is summarized as follows: 2. Trench Design: a. Percolation Rate: 6.5 to 27 minutes/inch b. Application Rate: .45 gallons/day/f~2 c. Number of Bedrooms: 4 d. Design Flow: 600 gallons per day e. Minimum Absorption Area: 1333 ft2 £ System Type: deep trench g. Effective Depth: 8 feet h. Width: 2 feet minimum. i. Length: 83.5 feet minimum 3, Surface Waters: Them are no surface waters within 100 feet of the proposed septic upgrade. 4. Slopes: The lot slopes downhill from south to north at approximately 3% grade, and downhill from east to west at approximately 5% grade. In short, the lot is relatively flat. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact me at 337-6179, or on my digital pager at 1-800-481-1162. Thank you. Sincerely, Jeffre, n P.E.M.S. Own~ Giffen 1 .wps SENT BY:rips-are-minerals ~t ; 3-21-96 ; 'FAX TRANSMITTAL l!' el ~o~* 8:86 ; nps-aro~ Water Well Data Sheet 9073383246;; L' Purpose: The purpose of this data sheet is to provide the Municipality of Anchorage, Department of Health & Human Services, with infon"nation regarding drilling and casing specifications for a water well drilled on the below identified lot. This well was drilled prior to 1975, before which time, submittal of Well logs was not required. Legal Land Description; T. 12 N., R, 3 W., S action 2'2, BLM Lot 44tA (a re subdivision of 8LM lot 44) Seward M eridian, Alaska Consisting of 207,900 sq ff (approximately 4.77 acres) Physical Address: 11525 Our Fid. Anchorage, Alaska 99518 Owner at the time the well was drilled: Mr. Johnston W~terWell Data; Drilled by: Paul Bergstedt, owner of Sunset Drilling Company Date Drilled: 1958. Well Icg: not available. Total well Depth'. 70 to 8o feet, Depth of casing: 70 to 80 feet to the bottom of the hole. Oasing perforation~ or screens', none, easing ,open at bottom of h01e. Well casing: 5 inch steel well casing, will accommodate standard pump (3-5/8 inches in diameter) Bedrock: not encountered Pitless adapter: 7 fl to 8 fl below surface. · The,above water well data is provided by Paul Bergstedt. Paul Bergstedt was · the ·owner and operator of Sunset Drilling who drilled the water well on the above referenced lot. Currently, Paul Bergstedt lives in Kilua Kens, Hawaii 00'0~'00" ~- 330.00' (P) 00'04%8" ~ 330.02' (~) 00,04'00" w 330.05' (~) C3 ~-~---0 oe ' "' /~ x,,~ ' 825 _ STREET ? .... ~,, ANCHORAGE, ALASKA 99b01 Karl Maerzluft Star Route A Box 1627-C //~ ~pproual ~or ~ho ~nd~v~dual sewor and va~er fac~k~es cannot be granted until the following items hav~ been completed: ~/ / (1) The water analysis report needs to be su~i~d ~ ~Sr~~ from the Chem Lab, 5633 B Shreet, for (2) A cleanout needs to be installed to %he sephic tank and leaching area. This is to insure proper distance requirements are met between ~he well and sewer system. (a) If the septic tank is 50 feet away and the leaching area is 100 feet away from the well, an adequacy test will need to be performed on %he existing leaching area. This test will determine if the system is adequate according to National Standards. A lishing of private firms performing the test is enclosed. This repor~ will need to be submitted this office for our review. (b) The septic tank needs to be pumped and verified for size. This will need to be verified by a registered engineer and the report submitted to this office. (2) In the event the tank, leaching area or both are less than the required distance from the well, an upgrade will be necessary. ~'~ ~ Kar 1' Maerzluft November 10, 1981 Page Two Prior to an upgrade, a soils test will need to be performed so that a permit can be issued by this department. If there are any further questions, please call this office at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist RCP/ljw _ ~ D/~T~-R EC EiV ED ~; INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE ,NSPECTOR ,NSPECTOR ,NSPEOTOR :¼ ~/~UNICiPALIT¥ OF ANCHOEAGE MUNICIPALITY OF ANCHORAGE DEPT. OF DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTEC~~ONM~NTAL OCT 3 0 ENVl RONMENTAL SANITATION DIVISION REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page J. Incomplete reques~ will not be proce~ed. Please allow ten (~0) days for processing. ~AILING ADDRESS PROPERTY RESIDENT (If different from a~ove) PHONE 2. BUYER / /" PHONE MAILING A~DRESS 3. LENDING INSTITUTION ~ PHONE MAILIN HESS 4. REALTOR/AGEN~ PHONE MAI LING ADDRESS ' / 5, LEGAL DESCRIPTION 6. TYPEOF RESIDENCE NUMBER (~BEDROOMS [] One [] Four [] Other ~ SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY [] Three [] Six 7, WATER SUPPLY '~ INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled [] COMMUNITY since June 1975, For wells drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach log if available,) 8. SEWAGE DISPOSAL SYSTEM ~ INDIVIDUAL/ON-SITE** ?', YEAR ON-SITE SYSTEM WAS INSTALLED. [] PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PR(~CESSING CAN BE INITIATED. 72-010 (Rev. 6/79) .z~.2~,,~ (HIS SIDE FOR OFFICIAL USE ONLY 1, TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER []INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER ~]Septic Tank or []Holding Tank Size: [f Tank is homemade SOILS RATING give dimensions: TYPE OF T~ANK MANUFACTURER TOTAL ABSQRPTION AREA MATERIAL 4, DISTANCESwELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line [] APPROVED FOFI BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [.~DISAPPROV ED 72-010 (Rev. 6/79)